Happy Farm Business Incubator. Happy Farm Business Incubator:
HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual...
Transcript of HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual...
Operatin
g M
an
ual
Operatin
g M
an
ual
HYBRIDIZATION INCUBATOR
YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600
TEL: 82-31-429-7471/2 FAX:82-31-429-7470 E-MAIL:[email protected]
combi-h12combi-d24combi-v12combi-sv12combi-sv120
Operating Manual Operating Manual
1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION4. USER OPERATION 5. ACCESSORIES6. MAINTENANCE AND CLEANING7. FAULTY RUNNING8. WARRANTY
combi-h12
combi-d24
combi-sv12
combi-v12
Hybridization incubators
(Dimension - external : W468XD435XH443, Internal : W365 X D280 X H286)
(Dimension - external : W508XD420XH703, Internal : W365 X D280 X H286)
(Dimension - external : W468XD435XH443, Internal : W365 X D280 X H286)
(Dimension - external : W468XD435XH443, Internal : W365 X D280 X H286)
Rotating + shaking movement
Rotating movement
PID temperature control
Variable accessories available
(Rotor, Rocking platform - optional)
Use a magnetic seal for closing door. As going time,
the door would be close more strongly.
Interior electrical outlet for powering small equipments
Use air layer for protecting inside heat in order to clean
environment and persist the temperature with stable.
5kind of safe device.
A. Electrical fuse
B. If current temp. does not reach the setting temp. for 2hours
ALM Lamp on temperature controller would be blinked.
C. This oven is used in up to 80˚C. if the current temp. is over
80.5˚C, ALM lamp would be blinked.
D. If the current temp. Is over 85˚C, the heater would be turned out.
E. If all the safe device of temperature does not work, all function
of this ovens should be stopped at 90˚C
Dual
Rocker + Shaking + Rotating
Rocker + Rotating
Rocker + Rotating
Rocker + Rotating
Combi-sv120(Dimension - external : W480XD420XH720, Internal : W363 X D278 X H545)
Rocker + Shaking + Rotating + Tachometer
1
PR
OD
UC
T D
ES
CR
IPT
ION
Introduction
combi-h12
combi-d24
combi-v12
HORIZONTAL TYPE
VERTICAL TYPE
* digital control temperature.* rotor speed control.* optional rocking platform for washing. (outside cabinet : W508XD420XH346mm)(inside chamber : W365XD280XH286mm)
* digital control temperature.* rotor speed control.* optional rocking platform for washing. (outside cabinet : W508XD420XH703mm)(inside chamber : W365XD280XH286mm)
* digital control temperature.* rotor speed control.* optional rocking platform for washing. (outside cabinet : W468XD435XH443mm)(inside chamber : W365XD280XH286mm)
* digital control temperature.* rotor speed control.* optional rocking platform for washing. (outside cabinet : W468XD435XH443mm)(inside chamber : W365XD280XH286mm)
Dual-type
standard size. Hybridization incubator.
12RK-H (rocking platform) can be settle
inside.
12RT- (accessories) series is for
combi-H12.
standard size.
Hybridization incubator.
12RK-H (rocking platform) can be settle
inside.
12RT- (accessories) series is for
combi-D24.
standard size. Hybridization incubator.
12RK-V (rocking platform) can be settle
inside.
12RT- (accessories) series is for
combi-V12.
standard size. Hybridization incubator.
12RK-SV (rocking platform) can be settle
inside.
12RT- (accessories) series is for
combi-SV12.
2
combi-sv12
Combi-sv120
* digital control temperature.* digital display speed. (tachometer)* rotor speed control & available select.* optional rocking platform for washing. (outside cabinet : W480XD420XH720mm)(inside chamber : W363XD278XH545mm)
standard size.
Hybridization incubator.
12RK-SV (rocking platform) can be settle
inside.
12RT- (accessories) series is for
combi-SV120.
PR
OD
UC
T D
ES
CR
IPT
ION
Difference of incubators
FINEMOULD PRECISION IND.CO.
POWER
Speed
OFF
19
8
7
2
3
45
6
HYBRIDIZATION INCUBATOR
COMBI-H
Temperature controller
Speed controller
ON/OFF switch
Magnetic sealerDoor
Rubber band
Glass
Temperature sensor
"U" plastic hub
BACK SIDE
MAIN BODY
Receptacle
TEMPERATURE CONTROLLER
Specification
Voltage / HzSerial Number
3Clutch
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
Current temperature
Setting temperature
MODE key
UP keyDOWN keyMOVE key
RUN/STOP key
RUN Lamp(orange)TIME Lamp(green)
HEAT Lamp(red)ALARM Lamp(red)
Specification
Description
PR
OD
UC
T D
ES
CR
IPT
ION
Ambient +5˚C ~ 80˚C
Model
Temp. Range
Temp. Accuracy
Temp. Timer
Dimensions(mm)
Weight
Wattage
Power
combi-D24combi-H12
±0.2˚C
99hour 59min
AC100V / 50/60HzAC110V / 50/60HzAC220V / 50/60HzAC230V / 50/60Hz(CE cert) AC240V / 50/60Hz
Speed- 0~300rpm
Overall W468 x D435 x H443
Internal W365 x D280 x H286
Material Inside chamber : Stainless steel
Rotation
Shaker
combi-V12 combi-SV12 combi-SV120
0~40rpm
26kg 51kg 30kg 36kg 46kg
Overall W508 x D420 x H703
Internal W365 x D280 x H286
Overall W468 x D435 x H443
Internal W365 x D280 x H286
Overall W480 x D420 x H720
Internal W363 x D278 x H545
Overall W468 x D435 x H443
Internal W365 x D280 x H286
400W 800W 400W 400W 800W
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODESTOP
FINEMOULD PRECISION IND.CO.
POWER
Speed
OFF
19
8
7
2
3
45
6
HYBRIDIZATION INCUBATOR
COMBI-H
FINEMOULD PRECISION IND.CO.
FINEMOULD PRECISION IND.CO.
FINEMOULD PRECISION IND.CO.
FINEMOULD PRECISION IND.CO.
FINEMOULD PRECISION IND.CO.
POWER
POWER
POWER
Speed
Speed
Speed
OFF
OFF
OFF
1
1
1
9
9
9
8
8
8
7
7
7
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
HYBRIDIZATION INCUBATOR
HYBRIDIZATION INCUBATOR
HYBRIDIZATION INCUBATOR
COMBI-H
COMBI-H
COMBI-H
TEMPERATURE
TEMPERATURE
C
C
V011
110V
220V
For place combi-V12, the SV12 and D24 horizontally with the ground, the two front screw foots could be used for making a balance.
Check if the voltage indicated on appliance corresponds to the local mains voltage before you connect the appliance.
Unplug the appliance : - If problems occur during the heating and rotating process.- Before you start cleaning the unit.- Never use the appliance if the plug, the cord or the appliance it self is damaged
Speed
OFF
19
8
7
2
3
45
6
FINEMOULD PRECISION IND.CO.
Do not place the hybridization incubators beside a sunny place or heater. If the main body is higher than room temperature, It could affects the inside setting temperature.
FINEMOULD PRECISION IND.CO.
10cm
Do not stand the instrument near a wall.On the back panel, There are ventilationholes. The instrument should be left fromat least 15cm.
Be careful not to drop any chemical liquid on the instrument to prolong the life of the instrument.For example, PEG could be reason for the paint on the surface to be peeled off.
Ventilation hole
FINEMOULD PRECISION IND.CO.
POWER
Speed
19
8
7
2
3
45
6
HYBRIDIZATION INCUBATOR
COMBI-H
Magnetic seal.
Keep the magnetic seal. If it is dust or have some particles,it could be possible the setting temperature is not stable.
4
User consideration
US
ER
CO
NS
IDE
RA
TIO
N
Environmental conditions- Indoor use.- Environment temperature 5˚C to 40˚C.- Maximum relative humidity 80% for temperatures up to 31˚C decreasing linearly to 50% relative humidity at 40˚C.- Mains supply voltage fluctuations not to exceed ±10% of the nominal voltage.- Other supply voltage fluctuations as stated by the manufacturer. - Transient overvoltages according to installation categories.
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOPSTOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOPSTOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
FINEMOULD PRECISION IND.CO.
FINEMOULD PRECISION IND.CO.
POWER
POWER
Speed
Speed
Speed
OFF
OFF
OFF
1
1
1
9
9
9
8
8
8
7
7
7
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
HYBRIDIZATION INCUBATOR
HYBRIDIZATION INCUBATOR
COMBI-H
COMBI-H
FINEMOULD PRECISION IND.CO.
POWER
Speed
OFF
19
8
7
2
3
45
6
HYBRIDIZATION INCUBATOR
COMBI-H
V022
1
2
3
5
8
9
10
11
12
This section summarizes operation procedures for FINEPCR`s hybridization ovenscontrolling the temperature and the rotate.
Check the name rating plate for the correct voltage, then plug the power cord into thereceptacle on back of the instrument.
Plug the power cordinto the wall receptacle.
Do not open with strong.The hinges of door could be defected.The door could be openeduntil 180
180
Open the rotor hook.
1. hole. 2. Push the rotor into the U-boss hole
Put into the clutch
Close the rotor hook
Turn the power ON/OFF control button to position'ON'
7
4
Put the shaft into the hole of clutchwith fitting with theshape of the hole.
"U" plastic hub
5
6
User operation
US
ER
OP
ER
AT
ION
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOPSTOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODESTOPSTOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODESTOP
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOPSTOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOPSTOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
p- 13
A
When switch turn on, (the type of sensor)is displayed on PV and (software vision)isdisplayed on SV for1second.
p
- 13A
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
25.045.0
After 1second,the current blockTEMPERATURE isdisplayed on PV andthe setting TEMPERATUREis displayed on SV.(This is normal MODE)
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
000p0
In order to set thedesired TEMPERATURE,press MODE key for1.5seconds thenis displayed on PV and the rightmost FND blinkon SV then stop pressingMODE key. Unless stop pressing MODE key, the setting return to normalMODE
p
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
0000p
0
At this step, forexample to set 45˚C,when press MOVE Keyeach TIME, the rightmostFND blink moves into left.Press MOVE key till therightmost FND blink movesinto the second place of right.TEMPERATURE range can beset per 0.1˚C
13
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
00p
50
When press UP key,the displayed figureincreases one by onethen press UP keycontinuously till thedisplayed figure reaches at 5.
6
User operation
US
ER
OP
ER
AT
ION
This section summarizes operation procedures for FINEPCR`s hybridization ovenscontrolling the temperature and the rotate.
14
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
45.0p
The figure shouldbe displayed at 45.0 to use MOVE,UP and DOWN key.
15
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
0000
16
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
0000Eep
P
Press MODE key onceagain after the settingof the TEMPERATURE then is displayed on PVand 00.00 is displayed on SV. TIME range canbe set to 99 Hours59minutes. Two positionsof the front are hour and next two positionsare Minute. The method of TIME setting is thesame as the method ofTEMPERATURE setting.
I e I e
Press MODE key onceagain after TIME settingthen is displayed on PV and 0000 is displayed on SV. sound time can be set to9999seconds.The method of BEEPsound time setting is the same as the method ofTEMPERATURE setting and TIME setting.
EepP
EepP
17
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
25.045.0
18
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
25.045.0
Press MODE key onceagain after the settingof BEEP sound timethen the screen returnto the step of no.3.Then the setting TEMPERATURE 45.0is displayed on SV.All of TEMPERATURE,TIME and beep soundtime setting are finished.You should return tonormal MODE. Press MODE key for 1.5secondsand stop pressing MODEkey when normal MODEhas been returned.
When normal MODE hasbeen returned, pressRUN key for 1.5secondsas per the shown picturethen RUN lamp is on andTEMPERATURE rises inbeginning.Then if the TIME has beenset, TIME lamp will be ontill to reach the settingTEMPERATURE and theTIME lamp will blink when theTEMPERATURE has reachedthe setting TEMPERATURE.Then you can know the timer is being operated well.Unless the TIME is sets, TIME lamp is not on.
7
User operation
US
ER
OP
ER
AT
ION
This section summarizes operation procedures for FINEPCR`s hybridization ovenscontrolling the temperature and the rotate.
21
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
25.0E
19
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
25.045.0
22
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
25.045.0
20
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
25.045.0
p
HEAT lamp let you know that power is supplyingthe heater normally whilethe unit is running.
After the setting TIMEhas passed. End is displayed on SV andthe setting BEEP soundbeeps for the settingBEEP sound time.Then press stop key BEEPsound will be stopped.Also, all functions will bestopped and will return to normal MODE.
Press RUN key for 1.5seconds at normalmode. The existingsetting TEMPERATURE,TIME and BEEP soundtime are kept in memory.Therefore, the unit will beoperated as the samemethod before. If you want to change the settingTEMPERATURE, TIME andBEEP sound time, pleasestart to reset all of the settingvalue from the step of NO.3.
If the TIME is set andyou want to see theset value while the unitis running, press MOVE key once then SV will be changedsetting TEMPERATUREto TIME. The TIMEdisplayed on the screenis reminder TIME and make it a rule to subtraction.
FINEMOULD PRECISION IND.CO.
POWER
Speed
OFF
19
8
7
2
3
45
6
HYBRIDIZATION INCUBATOR
COMBI-H
23 Install the sample bottles into putting the rotor clip by pushing
FINEMOULD PRECISION IND.CO.
POWER
Speed
OFF
19
8
7
2
3
45
6
HYBRIDIZATION INCUBATOR
COMBI-H
TEMPERATURE
1
2
3
45
6
7
8
9
OFF
24 Control the rotor speed (0~40rpm)
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOPSTOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOPSTOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
8
Accessories
AC
CE
SS
OR
IES
12RT~ standard for using it in other ovens except combi-H and combi-V12, combi-SV12, combi-SV120
12RT series
12RT-4 12RT-8 12RT-12
12RT-8V 12RT-24H12RT-16V12RT-12V
12RT200 series
12RT200-64 12RT200-12812RT200-96
Other
12RT-8V 12RT-24H12RT-16V12RT-12V
12RK-H HY-Bag12 shelf12H-DT
BOTTLES
BT40-120 (40mm diameter X 120mm length bottle with silicon cap)
BT40-200 (40mm diameter X 200mm length bottle with silicon cap)
BT60-200 (60mm diameter X 200mm length bottle with silicon cap)
BT80-200 (80mm diameter X 200mm length bottle with silicon cap)
How to install Rocking platform
FINEMOULD PRECISION IND.CO.
POWER
Speed
OFF
19
8
7
2
3
45
6
HYBRIDIZATION INCUBATOR
COMBI-H
FINEMOULD PRECISION IND.CO.
POWER
Speed
OFF
19
8
7
2
3
45
6
HYBRIDIZATION INCUBATOR
COMBI-H
Drip Tray Drip Tray
Place Drip tray until touching the wall pannel of incubatorfor ventilation smoothly.
Hot air circulation
9
Make a right angle the connecting bar with rocking platform
User operation
US
ER
OP
ER
AT
ION
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOPSTOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOPSTOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
FINEMOULD PRECISION IND.CO.
POWER
Speed
OFF
19
8
7
2
3
45
6
HYBRIDIZATION INCUBATOR
COMBI-H
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOPSTOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
10
User operation
US
ER
OP
ER
AT
ION
How to install ROTOR
Put into rotor and thenput the hook into a gap
Put a right side of rotorinto a hole
Always unplug the instrument before you start cleaning it.
Never immerse the appliance in water.
FINEMOULD PRECISION IND.CO.
POWER
Speed
OFF
19
8
7
2
3
45
6
HYBRIDIZATION INCUBATOR
COMBI-H
Magnetic sealingKeep the magnetic sealing clean for insulation.Clean the magnetic sealing, caseand door with a damp cloth orwith detergent.
11
Never use the instrument if the plug, the cord or the instrument itself is damaged.
STOP
RUN ●
TIME ●
HEAT ●
ALM ●
PV
SV
˚C
RUNMODE
STOP
Maintenance and Cleaning
MA
INT
EN
AN
CE
AN
D C
LE
AN
ING
1. The current and setting temperature is different
- Temperature bar may not corrected, After testing the inside temperatures with several temp. bars at the same time, you could calibrate by referring calibrating temperature section of technical specification.
2. The rotor speed dose not meet a requirement.
- FINEPCR's units could be controlled in Maximum and Minimum speed. Set the speed to the desired speed. (Refer the Max/Min speed control section of technical specification)
3. After turning on the power switch, The LED of the temperature controller could not display current temp.
- In this case, the electronic fuse is broken. If you see the back of the incubator, the fuse box could be seen. After detaching the box as the pictures, change the fuse.
12
If the equipment have other defects, It should be informed to an authorized servicing agent.
spare fuse
remove used fuse
Faulty running
FA
ULT
Y R
UN
NIN
G
1 YEAR WARRANTY
Limited Warranty :
This equipment has been tested all the functions and parts for proper operationbefore shipment.Please read this manual carefully. If youhave any questions or problems, checkwith your dealer or write us direct.This equipment is warranted for a period of 1year from date of purchase againstdefects in workmanship and material only.If a system component should ever fail to work perfectly. It can be repaired or replaced by our after-sales service withoutdifficulty.
Model#:
Serial# :
Date Purchased :
Dealer Name :
City and Country :
YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600
TEL: 82-31-429-7471/2 FAX:82-31-429-7470 E-MAIL:[email protected]
WA
RR
AN
TY
Warranty