HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual...

14
Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2 FAX:82-31-429-7470 E-MAIL:[email protected] Www.finepcr.com combi-h12 combi-d24 combi-v12 combi-sv12 combi-sv120 Operating Manual Operating Manual 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 4. USER OPERATION 5. ACCESSORIES 6. MAINTENANCE AND CLEANING 7. FAULTY RUNNING 8. WARRANTY

Transcript of HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual...

Page 1: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

Operatin

g M

an

ual

Operatin

g M

an

ual

HYBRIDIZATION INCUBATOR

YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600

TEL: 82-31-429-7471/2 FAX:82-31-429-7470 E-MAIL:[email protected]

combi-h12combi-d24combi-v12combi-sv12combi-sv120

Operating Manual Operating Manual

1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION4. USER OPERATION 5. ACCESSORIES6. MAINTENANCE AND CLEANING7. FAULTY RUNNING8. WARRANTY

Page 2: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

combi-h12

combi-d24

combi-sv12

combi-v12

Hybridization incubators

(Dimension - external : W468XD435XH443, Internal : W365 X D280 X H286)

(Dimension - external : W508XD420XH703, Internal : W365 X D280 X H286)

(Dimension - external : W468XD435XH443, Internal : W365 X D280 X H286)

(Dimension - external : W468XD435XH443, Internal : W365 X D280 X H286)

Rotating + shaking movement

Rotating movement

PID temperature control

Variable accessories available

(Rotor, Rocking platform - optional)

Use a magnetic seal for closing door. As going time,

the door would be close more strongly.

Interior electrical outlet for powering small equipments

Use air layer for protecting inside heat in order to clean

environment and persist the temperature with stable.

5kind of safe device.

A. Electrical fuse

B. If current temp. does not reach the setting temp. for 2hours

ALM Lamp on temperature controller would be blinked.

C. This oven is used in up to 80˚C. if the current temp. is over

80.5˚C, ALM lamp would be blinked.

D. If the current temp. Is over 85˚C, the heater would be turned out.

E. If all the safe device of temperature does not work, all function

of this ovens should be stopped at 90˚C

Dual

Rocker + Shaking + Rotating

Rocker + Rotating

Rocker + Rotating

Rocker + Rotating

Combi-sv120(Dimension - external : W480XD420XH720, Internal : W363 X D278 X H545)

Rocker + Shaking + Rotating + Tachometer

1

PR

OD

UC

T D

ES

CR

IPT

ION

Introduction

Page 3: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

combi-h12

combi-d24

combi-v12

HORIZONTAL TYPE

VERTICAL TYPE

* digital control temperature.* rotor speed control.* optional rocking platform for washing. (outside cabinet : W508XD420XH346mm)(inside chamber : W365XD280XH286mm)

* digital control temperature.* rotor speed control.* optional rocking platform for washing. (outside cabinet : W508XD420XH703mm)(inside chamber : W365XD280XH286mm)

* digital control temperature.* rotor speed control.* optional rocking platform for washing. (outside cabinet : W468XD435XH443mm)(inside chamber : W365XD280XH286mm)

* digital control temperature.* rotor speed control.* optional rocking platform for washing. (outside cabinet : W468XD435XH443mm)(inside chamber : W365XD280XH286mm)

Dual-type

standard size. Hybridization incubator.

12RK-H (rocking platform) can be settle

inside.

12RT- (accessories) series is for

combi-H12.

standard size.

Hybridization incubator.

12RK-H (rocking platform) can be settle

inside.

12RT- (accessories) series is for

combi-D24.

standard size. Hybridization incubator.

12RK-V (rocking platform) can be settle

inside.

12RT- (accessories) series is for

combi-V12.

standard size. Hybridization incubator.

12RK-SV (rocking platform) can be settle

inside.

12RT- (accessories) series is for

combi-SV12.

2

combi-sv12

Combi-sv120

* digital control temperature.* digital display speed. (tachometer)* rotor speed control & available select.* optional rocking platform for washing. (outside cabinet : W480XD420XH720mm)(inside chamber : W363XD278XH545mm)

standard size.

Hybridization incubator.

12RK-SV (rocking platform) can be settle

inside.

12RT- (accessories) series is for

combi-SV120.

PR

OD

UC

T D

ES

CR

IPT

ION

Difference of incubators

Page 4: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

FINEMOULD PRECISION IND.CO.

POWER

Speed

OFF

19

8

7

2

3

45

6

HYBRIDIZATION INCUBATOR

COMBI-H

Temperature controller

Speed controller

ON/OFF switch

Magnetic sealerDoor

Rubber band

Glass

Temperature sensor

"U" plastic hub

BACK SIDE

MAIN BODY

Receptacle

TEMPERATURE CONTROLLER

Specification

Voltage / HzSerial Number

3Clutch

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

Current temperature

Setting temperature

MODE key

UP keyDOWN keyMOVE key

RUN/STOP key

RUN Lamp(orange)TIME Lamp(green)

HEAT Lamp(red)ALARM Lamp(red)

Specification

Description

PR

OD

UC

T D

ES

CR

IPT

ION

Ambient +5˚C ~ 80˚C

Model

Temp. Range

Temp. Accuracy

Temp. Timer

Dimensions(mm)

Weight

Wattage

Power

combi-D24combi-H12

±0.2˚C

99hour 59min

AC100V / 50/60HzAC110V / 50/60HzAC220V / 50/60HzAC230V / 50/60Hz(CE cert) AC240V / 50/60Hz

Speed- 0~300rpm

Overall W468 x D435 x H443

Internal W365 x D280 x H286

Material Inside chamber : Stainless steel

Rotation

Shaker

combi-V12 combi-SV12 combi-SV120

0~40rpm

26kg 51kg 30kg 36kg 46kg

Overall W508 x D420 x H703

Internal W365 x D280 x H286

Overall W468 x D435 x H443

Internal W365 x D280 x H286

Overall W480 x D420 x H720

Internal W363 x D278 x H545

Overall W468 x D435 x H443

Internal W365 x D280 x H286

400W 800W 400W 400W 800W

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODESTOP

Page 5: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

FINEMOULD PRECISION IND.CO.

POWER

Speed

OFF

19

8

7

2

3

45

6

HYBRIDIZATION INCUBATOR

COMBI-H

FINEMOULD PRECISION IND.CO.

FINEMOULD PRECISION IND.CO.

FINEMOULD PRECISION IND.CO.

FINEMOULD PRECISION IND.CO.

FINEMOULD PRECISION IND.CO.

POWER

POWER

POWER

Speed

Speed

Speed

OFF

OFF

OFF

1

1

1

9

9

9

8

8

8

7

7

7

2

2

2

3

3

3

4

4

4

5

5

5

6

6

6

HYBRIDIZATION INCUBATOR

HYBRIDIZATION INCUBATOR

HYBRIDIZATION INCUBATOR

COMBI-H

COMBI-H

COMBI-H

TEMPERATURE

TEMPERATURE

C

C

V011

110V

220V

For place combi-V12, the SV12 and D24 horizontally with the ground, the two front screw foots could be used for making a balance.

Check if the voltage indicated on appliance corresponds to the local mains voltage before you connect the appliance.

Unplug the appliance : - If problems occur during the heating and rotating process.- Before you start cleaning the unit.- Never use the appliance if the plug, the cord or the appliance it self is damaged

Speed

OFF

19

8

7

2

3

45

6

FINEMOULD PRECISION IND.CO.

Do not place the hybridization incubators beside a sunny place or heater. If the main body is higher than room temperature, It could affects the inside setting temperature.

FINEMOULD PRECISION IND.CO.

10cm

Do not stand the instrument near a wall.On the back panel, There are ventilationholes. The instrument should be left fromat least 15cm.

Be careful not to drop any chemical liquid on the instrument to prolong the life of the instrument.For example, PEG could be reason for the paint on the surface to be peeled off.

Ventilation hole

FINEMOULD PRECISION IND.CO.

POWER

Speed

19

8

7

2

3

45

6

HYBRIDIZATION INCUBATOR

COMBI-H

Magnetic seal.

Keep the magnetic seal. If it is dust or have some particles,it could be possible the setting temperature is not stable.

4

User consideration

US

ER

CO

NS

IDE

RA

TIO

N

Environmental conditions- Indoor use.- Environment temperature 5˚C to 40˚C.- Maximum relative humidity 80% for temperatures up to 31˚C decreasing linearly to 50% relative humidity at 40˚C.- Mains supply voltage fluctuations not to exceed ±10% of the nominal voltage.- Other supply voltage fluctuations as stated by the manufacturer. - Transient overvoltages according to installation categories.

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOPSTOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOPSTOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

Page 6: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

FINEMOULD PRECISION IND.CO.

FINEMOULD PRECISION IND.CO.

POWER

POWER

Speed

Speed

Speed

OFF

OFF

OFF

1

1

1

9

9

9

8

8

8

7

7

7

2

2

2

3

3

3

4

4

4

5

5

5

6

6

6

HYBRIDIZATION INCUBATOR

HYBRIDIZATION INCUBATOR

COMBI-H

COMBI-H

FINEMOULD PRECISION IND.CO.

POWER

Speed

OFF

19

8

7

2

3

45

6

HYBRIDIZATION INCUBATOR

COMBI-H

V022

1

2

3

5

8

9

10

11

12

This section summarizes operation procedures for FINEPCR`s hybridization ovenscontrolling the temperature and the rotate.

Check the name rating plate for the correct voltage, then plug the power cord into thereceptacle on back of the instrument.

Plug the power cordinto the wall receptacle.

Do not open with strong.The hinges of door could be defected.The door could be openeduntil 180

180

Open the rotor hook.

1. hole. 2. Push the rotor into the U-boss hole

Put into the clutch

Close the rotor hook

Turn the power ON/OFF control button to position'ON'

7

4

Put the shaft into the hole of clutchwith fitting with theshape of the hole.

"U" plastic hub

5

6

User operation

US

ER

OP

ER

AT

ION

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOPSTOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODESTOPSTOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODESTOP

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOPSTOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOPSTOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

p- 13

A

When switch turn on, (the type of sensor)is displayed on PV and (software vision)isdisplayed on SV for1second.

p

- 13A

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

25.045.0

After 1second,the current blockTEMPERATURE isdisplayed on PV andthe setting TEMPERATUREis displayed on SV.(This is normal MODE)

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

000p0

In order to set thedesired TEMPERATURE,press MODE key for1.5seconds thenis displayed on PV and the rightmost FND blinkon SV then stop pressingMODE key. Unless stop pressing MODE key, the setting return to normalMODE

p

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

0000p

0

At this step, forexample to set 45˚C,when press MOVE Keyeach TIME, the rightmostFND blink moves into left.Press MOVE key till therightmost FND blink movesinto the second place of right.TEMPERATURE range can beset per 0.1˚C

13

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

00p

50

When press UP key,the displayed figureincreases one by onethen press UP keycontinuously till thedisplayed figure reaches at 5.

Page 7: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

6

User operation

US

ER

OP

ER

AT

ION

This section summarizes operation procedures for FINEPCR`s hybridization ovenscontrolling the temperature and the rotate.

14

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

45.0p

The figure shouldbe displayed at 45.0 to use MOVE,UP and DOWN key.

15

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

0000

16

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

0000Eep

P

Press MODE key onceagain after the settingof the TEMPERATURE then is displayed on PVand 00.00 is displayed on SV. TIME range canbe set to 99 Hours59minutes. Two positionsof the front are hour and next two positionsare Minute. The method of TIME setting is thesame as the method ofTEMPERATURE setting.

I e I e

Press MODE key onceagain after TIME settingthen is displayed on PV and 0000 is displayed on SV. sound time can be set to9999seconds.The method of BEEPsound time setting is the same as the method ofTEMPERATURE setting and TIME setting.

EepP

EepP

17

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

25.045.0

18

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

25.045.0

Press MODE key onceagain after the settingof BEEP sound timethen the screen returnto the step of no.3.Then the setting TEMPERATURE 45.0is displayed on SV.All of TEMPERATURE,TIME and beep soundtime setting are finished.You should return tonormal MODE. Press MODE key for 1.5secondsand stop pressing MODEkey when normal MODEhas been returned.

When normal MODE hasbeen returned, pressRUN key for 1.5secondsas per the shown picturethen RUN lamp is on andTEMPERATURE rises inbeginning.Then if the TIME has beenset, TIME lamp will be ontill to reach the settingTEMPERATURE and theTIME lamp will blink when theTEMPERATURE has reachedthe setting TEMPERATURE.Then you can know the timer is being operated well.Unless the TIME is sets, TIME lamp is not on.

Page 8: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

7

User operation

US

ER

OP

ER

AT

ION

This section summarizes operation procedures for FINEPCR`s hybridization ovenscontrolling the temperature and the rotate.

21

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

25.0E

19

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

25.045.0

22

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

25.045.0

20

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

25.045.0

p

HEAT lamp let you know that power is supplyingthe heater normally whilethe unit is running.

After the setting TIMEhas passed. End is displayed on SV andthe setting BEEP soundbeeps for the settingBEEP sound time.Then press stop key BEEPsound will be stopped.Also, all functions will bestopped and will return to normal MODE.

Press RUN key for 1.5seconds at normalmode. The existingsetting TEMPERATURE,TIME and BEEP soundtime are kept in memory.Therefore, the unit will beoperated as the samemethod before. If you want to change the settingTEMPERATURE, TIME andBEEP sound time, pleasestart to reset all of the settingvalue from the step of NO.3.

If the TIME is set andyou want to see theset value while the unitis running, press MOVE key once then SV will be changedsetting TEMPERATUREto TIME. The TIMEdisplayed on the screenis reminder TIME and make it a rule to subtraction.

FINEMOULD PRECISION IND.CO.

POWER

Speed

OFF

19

8

7

2

3

45

6

HYBRIDIZATION INCUBATOR

COMBI-H

23 Install the sample bottles into putting the rotor clip by pushing

FINEMOULD PRECISION IND.CO.

POWER

Speed

OFF

19

8

7

2

3

45

6

HYBRIDIZATION INCUBATOR

COMBI-H

TEMPERATURE

1

2

3

45

6

7

8

9

OFF

24 Control the rotor speed (0~40rpm)

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOPSTOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOPSTOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

Page 9: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

8

Accessories

AC

CE

SS

OR

IES

12RT~ standard for using it in other ovens except combi-H and combi-V12, combi-SV12, combi-SV120

12RT series

12RT-4 12RT-8 12RT-12

12RT-8V 12RT-24H12RT-16V12RT-12V

12RT200 series

12RT200-64 12RT200-12812RT200-96

Other

12RT-8V 12RT-24H12RT-16V12RT-12V

12RK-H HY-Bag12 shelf12H-DT

BOTTLES

BT40-120 (40mm diameter X 120mm length bottle with silicon cap)

BT40-200 (40mm diameter X 200mm length bottle with silicon cap)

BT60-200 (60mm diameter X 200mm length bottle with silicon cap)

BT80-200 (80mm diameter X 200mm length bottle with silicon cap)

Page 10: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

How to install Rocking platform

FINEMOULD PRECISION IND.CO.

POWER

Speed

OFF

19

8

7

2

3

45

6

HYBRIDIZATION INCUBATOR

COMBI-H

FINEMOULD PRECISION IND.CO.

POWER

Speed

OFF

19

8

7

2

3

45

6

HYBRIDIZATION INCUBATOR

COMBI-H

Drip Tray Drip Tray

Place Drip tray until touching the wall pannel of incubatorfor ventilation smoothly.

Hot air circulation

9

Make a right angle the connecting bar with rocking platform

User operation

US

ER

OP

ER

AT

ION

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOPSTOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOPSTOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

Page 11: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

FINEMOULD PRECISION IND.CO.

POWER

Speed

OFF

19

8

7

2

3

45

6

HYBRIDIZATION INCUBATOR

COMBI-H

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOPSTOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

10

User operation

US

ER

OP

ER

AT

ION

How to install ROTOR

Put into rotor and thenput the hook into a gap

Put a right side of rotorinto a hole

Page 12: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

Always unplug the instrument before you start cleaning it.

Never immerse the appliance in water.

FINEMOULD PRECISION IND.CO.

POWER

Speed

OFF

19

8

7

2

3

45

6

HYBRIDIZATION INCUBATOR

COMBI-H

Magnetic sealingKeep the magnetic sealing clean for insulation.Clean the magnetic sealing, caseand door with a damp cloth orwith detergent.

11

Never use the instrument if the plug, the cord or the instrument itself is damaged.

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

Maintenance and Cleaning

MA

INT

EN

AN

CE

AN

D C

LE

AN

ING

Page 13: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

1. The current and setting temperature is different

- Temperature bar may not corrected, After testing the inside temperatures with several temp. bars at the same time, you could calibrate by referring calibrating temperature section of technical specification.

2. The rotor speed dose not meet a requirement.

- FINEPCR's units could be controlled in Maximum and Minimum speed. Set the speed to the desired speed. (Refer the Max/Min speed control section of technical specification)

3. After turning on the power switch, The LED of the temperature controller could not display current temp.

- In this case, the electronic fuse is broken. If you see the back of the incubator, the fuse box could be seen. After detaching the box as the pictures, change the fuse.

12

If the equipment have other defects, It should be informed to an authorized servicing agent.

spare fuse

remove used fuse

Faulty running

FA

ULT

Y R

UN

NIN

G

Page 14: HYBRIDIZATION INCUBATOR combi Operating Manual Operating ... · Operating Manual Operating Manual HYBRIDIZATION INCUBATOR YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2

1 YEAR WARRANTY

Limited Warranty :

This equipment has been tested all the functions and parts for proper operationbefore shipment.Please read this manual carefully. If youhave any questions or problems, checkwith your dealer or write us direct.This equipment is warranted for a period of 1year from date of purchase againstdefects in workmanship and material only.If a system component should ever fail to work perfectly. It can be repaired or replaced by our after-sales service withoutdifficulty.

Model#:

Serial# :

Date Purchased :

Dealer Name :

City and Country :

YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600

TEL: 82-31-429-7471/2 FAX:82-31-429-7470 E-MAIL:[email protected]

WA

RR

AN

TY

Warranty