BCAL Dimensions (CDR)

o Length: 4 mo Outer Radius: 90 cm

o Thickness: 20-25 cm (~16X0)

o Pb Radiation Length: 1X0 = 0.56 cm

No. of modules: 48 (96 phi slices)No. of PMTs: 12 x 48 = 576

Page 3: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

BCAL 96 Phi/Readout Slices

1st face width 4.25 cm

2nd face width 4.80 cm

3rd face width 5.35 cm

4th face width 5.90 cm

HPMT outer diameterHPMT active diameter

5.60 cm2.55 cm

Each PhiSegment side

Total Area210 cm2

Area Reduction

4:1

HPMT Area5 cm2

No of HPMTs10

Page 4: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

HPMT Old Geometry (6 PMTs)

5.90 cm

5.35 cm

4.80 cm

4.25 cm HPMT

Staggered HPMTs

DEP-PP0350G 5.60 cm outer diameter 2.55 cm active diameter

Al plate 2.5 cm

Page 5: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

A tight squeeze!

KLOE Winston Cones – Module-0

Page 6: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

HPMT New Geometry (10 PMTs)?

Staggered HPMTs

DEP-PP0350G 5.60 cm outer diameter 2.55 cm active diameter

4.25 cm

HPMT

Al plate 2.5 cm

5.90 cm

4.80 cm

5.35 cm

Tough-cookie design!Solution:

DEP redesigns theelectronics housing

Page 7: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

What’s a Hybrid?

Proximity-focused vacuum tubeFast rise- and fall-time (2, 12 ns)High QE for UV, Gain is 105

Insensitive to high magnetic fields

Fused silica window

HV: -8kVBias: -80VPre-ampShaper

Page 8: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

HPMT Electronic Circuit

Page 9: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

The real McCoy…

DEP PP0350G

DEP PP0100Z

UofR HV regulator

Page 10: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

Up close and personal

Page 11: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

HPMT UofR Housing

Page 12: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

Preliminary HPMT tests

Discharging problem: partly solvedPre-amp selection: solvedSignals observed from radioactivity source using a NaI detectorDirect communication with DEP establishedPersonnel: Electronics engineer, technician, postdoc

(Vitaly Kovaltchouk)

Page 13: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

Regina “Flasher”

Was recently apprehended. Replacement: Optitron Xe-N Flasher System 200 psi 20 kV across the electrodes Pulse resembles scintillator pulse Externally triggered, frequency

controlled, or single flash modes

Page 14: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

Flasher Tube

Page 15: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

Flasher Test Setup

Page 16: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

Zooming in…

Page 17: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

HPMT Testing Chores

Need to perfect the electronic circuit Fast charge pre-amp Suitable pulse shaper HV-rated cables

Communicate with DEP Modify the detector design Transfer knowledge

Bench tests Operate with Flasher Operate with Cosmic Rays

Page 18: Hybrid PMT Tests & Geometry Zisis Papandreou Detector Interface Meeting Bloomington, Indiana November 1 st, 2001.

HPMT Geometry List

Optimize area reduction (4:1)Light guides and Winston ConesHPMTs must be staggered for clearanceNo. of HPMTs must be settledGUIDEIT MC simulations requiredGood neighbor policy: Solenoid Drift chambers