November 01, 2013 _Sector Confidential 1
Hybrid Suite New Imaging technologies for SHD, CHD and TAVR
November 01, 2013 _Sector Confidential 2
Growth in SHD, CHD &TAVR
• TAVI • LAA Closure • Mitral Valve
clipping • ASD/VSD
closure • PVL closure • RPA
November 01, 2013 _Sector Confidential 3
BALANCE OF USE CATHLAB OR A HYBRID ROOM
November 01, 2013 _Sector Confidential 4
THE HYBRID OPERATING ROOM
+ =
Fusion of a cathlab with an operating room:
Cathlab Operating room
November 01, 2013 _Sector Confidential 5
Trends in Interventional Hybrid
• Multiple clinical domains – Cardiac
– Vascular/Neuro
– Ortho
• Drivers:
– Less physical impact to patient
– Shorter recovery time
High growth impact
November 01, 2013 _Sector Confidential 6
CHALLENGE
MAGNUS
IT
WORKFLOW
LAF
PACS
PATIENT
USER
AN
GIO
-SYSTEM
TRADES
HEART
LU
NG
November 01, 2013 _Sector Confidential 7
Flexibility in a packed room
University Zuerich, Switzerland
November 01, 2013 _Sector Confidential 8
Room considerations Hybrid OR with FlexMove example
ROOM PLANNING 10.2 m / 33 ft
8.2
m / 2
6 f
t
4 m / 13 ft
Nurse Area
Hybrid OR
Control Room
November 01, 2013 _Sector Confidential 9
Room considerations Hybrid OR with FlexMove example
iXR Surgery, Hybrid OR Solutions, 2010
November 01, 2013 _Sector Confidential 10
November 01, 2013 _Sector Confidential 11
Why ceiling mounted solution?
Ceiling Mobile Floor Fixed Floor
November 01, 2013 _Sector Confidential 12
Why ceiling mounted solution?
Small footprint & good patient accessibility
Keep floor clear for other equipment
Full body imaging at both sides of table
Head-end free for anesthesia
Flexible setup
Flexible parking including at foot-end
Predictable movement
November 01, 2013 _Sector Confidential 13
Setup- Open surgery
• FlexMove outside treatment area
• OT lights in place
• Full laminar down flow
November 01, 2013 _Sector Confidential 14
TAVI – Trans-apical access
November 01, 2013 _Sector Confidential 15
EVAR – Access on both sides
• Monitors left and right from gantry
• No need to turn patient
November 01, 2013 _Sector Confidential 16
FlexMove meets highest sterility standards - Class 1A room FlexMove fulfills
ISO-9001 norm DIN-1946-4 norm: Raumklasse 1A
November 01, 2013 _Sector Confidential 17
Patient support for open and endovascular • Endovascular OT angio-table:
– Tilt & cradle function
– Free float
• Integrated OT table
• Exchange table top
– Semi float
– Synchronized with gantry
– Full body coverage with long table top
– Motorized float
November 01, 2013 _Sector Confidential 18
Examples of Hybrid Cardiovascular systems in the OR
November 01, 2013 _Sector Confidential 19
Mount Elisabeth Novena hospital, Singapore
November 01, 2013 _Sector Confidential 20
Bangkok Group Hospital
November 01, 2013 _Sector Confidential 21
Siriraj, Bangkok, Thailand
November 01, 2013 _Sector Confidential 22
Jakarta Heart Center
November 01, 2013 _Sector Confidential 23
RS Zainoel Abidin, Aceh
November 01, 2013 _Sector Confidential 24
Hybrid OT installed base .
2010-2014 41
Australia 2
Indonesia 2
India 2
Japan 26
Korea 1
Mayalsia 1
New Zealand 1
Singapore 3
Thailand 3
Total globally over: • 200 systems with FlexMove • 300 hybrid systems
November 01, 2013 _Sector Confidential 25