HUGE-NDT: ULTRASCHALL- PHASED -ARRAY-METHODE .HUGE-NDT ist eine neue...

download HUGE-NDT: ULTRASCHALL- PHASED -ARRAY-METHODE .HUGE-NDT ist eine neue Ultraschall-Phased-Array-Methode,

If you can't read please download the document

  • date post

    18-Sep-2018
  • Category

    Documents

  • view

    217
  • download

    0

Embed Size (px)

Transcript of HUGE-NDT: ULTRASCHALL- PHASED -ARRAY-METHODE .HUGE-NDT ist eine neue...

  • F R A U N H O F E R - I N S T I T U T F R K E R A M I S C H E T E C H N O L O G I E N U N D S Y S T E M E I K T S

    HUGE-NDT: ULTRASCHALL- PHASED-ARRAY-METHODE

    Prfung von Rundschweinhten an

    dnnwandigen Rohren

    HUGE-NDT ist eine neue Ultraschall-

    Phased-Array-Methode, die fr die halb-

    automatisierte Prfung von Rundschwei-

    nhten dnnwandiger Rohre mit Wanddi-

    cken von unter 6 mm optimiert wurde. Mit

    diesem Verfahren kann die aufwendige

    Radiographie-Prfung ersetzt werden.

    Durch die schnelle Arbeitsweise knnen

    Anlagenbetreiber Kosten in Millionenhhe

    einsparen. HUGE-NDT kann in verschiede-

    nen Typen von Kraftwerken, in der chemi-

    schen Industrie und vielen anderen Berei-

    chen eingesetzt werden. Bis jetzt konnten

    bereits ber 6000 Schweinhte mit HUGE-

    NDT erfolgreich in Kohlekraftwerken ge-

    prft werden.

    Vorteile von HUGE-NDT

    - Das System ist viel schneller und preis-werter als die bisher eingesetzte Radio-

    graphie-Methode

    - Hohe Fehlerauffindwahrscheinlichkeit fr Fehler mit Kerbwirkung (Risse, Binde-

    fehler)

    - Mit Hilfe optimierter Einsatzplne kn-nen Kraftwerke schon nach der Hlfte

    der bisher bei einer Revision oder St-

    rung bentigten Zeit wieder arbeiten

    - Funktioniert an martensitischem und austenitischen Stahl

    - Kleines und handliches Equipment - Kein Strahlenschutz muss beachtet

    werden

    - Geringere Personalkosten - Optimierte Dokumentation und sicher

    Rckfhrbarkeit der Ergebnisse

    HUGE-NDT wird mit Standard-Phased-

    Array-Equipment durchgefhrt. Das Verfah-

    ren wurde unter Praxisbedingungen im

    Kohlekraftwerk getestet und optimiert.

    HUGE-NDT ist vom Fraunhofer IKTS vali-

    diert und die Validierung von den zulassen-

    den Stellen in Kraftwerken akzeptiert wor-

    den.

    Fraunhofer-Institut fr Keramische

    Technologien und Systeme IKTS

    Maria-Reiche-Strae 2

    01109 Dresden

    Ansprechpartner

    Susanne Hillmann

    Telefon 0351 88815-552

    susanne.hillmann@ikts.fraunhofer.de

    www.ikts.fraunhofer.de

    1 Sektorscan an einer Schweinaht. 2 Anwendung im Kraftwerk. 3 HUGE-NDT-Prfsystem.

    1 2

  • F R A U N H O F E R I N S T I T U T E F O R C E R A M I C T E C H N O L O G I E S A N D S Y S T E M S I K T S

    HUGE-NDT: ULTRASONIC PHASED-ARRAY TECHNIQUE

    Flaw detection in circumferential welds

    of thin-walled pipes

    HUGE-NDT is a new ultrasonic phased-array

    technique. It is optimized for semiauto-

    mated testing of circumferential welds on

    thin-walled pipes (wall thickness < 6 mm).

    Using this process, the enormous efforts

    required by radiography testing is not

    needed any more. Due to fast processing,

    plant operators can reduce their cost in the

    million dollar range. Applications are possi-

    ble in various types of power plants, chemi-

    cal industry and much more. Until now,

    more than 6,000 welds have been tested in

    conventional power plants using HUGE-

    NDT.

    Advantages of HUGE-NDT

    - The system is much faster and less ex-pensive than previously used radiog-

    raphy methods

    - High probability of flaw detection in welds with notch effects

    - Using optimized operation schedules for test personnel, power plants can com-

    plete their maintenance period in half of

    the previous inspection time

    - Works on austenitic stainless steel and martensitic steel

    - Very high production rate - Small and handy testing equipment - No radiation protection required - Lower manpower requirements - Optimized documentation and reliable

    traceability due to electronic storage of

    the entire scan of the weld

    HUGE-NDT uses standard ultrasonic

    phased-array equipment. The technique

    has been optimized and was tested under

    real-life conditions in power plants. HUGE-

    NDT is validated by Fraunhofer IKTS and

    accepted by all responsible power plant

    personnel. The HUGE-NDT technique is

    currently being established in Europe.

    1 Sector scan on a stainless-steel weld. 2 Power plant application. 3 HUGE-NDT test system.

    Fraunhofer Institute for Ceramic

    Technologies and Systems IKTS

    Maria-Reiche-Strasse 2

    01109 Dresden, Germany

    Contact

    Susanne Hillmann

    Phone +49 351 88815-552

    susanne.hillmann@ikts.fraunhofer.de

    www.ikts.fraunhofer.de

    3

    821-W-15-5-7

    Prfung von Rundschweinhten an dnnwandigen RohrenVorteile von HUGE-NDT

    Flaw detection in circumferential welds of thin-walled pipesAdvantages of HUGE-NDT

    /ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages false /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth 8 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /FlateEncode /AutoFilterGrayImages false /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages false /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile (None) /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False

    /CreateJDFFile false /Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure true /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles true /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /NA /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /LeaveUntagged /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice