Huawei NE40E Router Quick Ordering Guide
Product Overview
The NetEngine40E series universal service router (NE40E) is a family of high-end
network products that are usually deployed at the edges of Internet Protocol (IP)
backbone networks, IP Metropolitan Area Networks (MANs), and other large-scale IP
networks. The NE40E, ME60, NE20E-S and NE5000E together provide a complete,
layered IP network solution.
The NE40E can be flexibly deployed at the edge or core of IP or MPLS networks,
simplifying the network structure. With its ability to provide an extensive range of services
with reliable service quality, the NE40E is enabling IP and MPLS bearer networks to
develop greater broadband capacity and to become more secure, intelligent, and
service-oriented. Based on distributed hardware forwarding and non-blocking switching
technologies, the NE40E features line-rate forwarding capability, a well designed Quality
of Service (QoS) mechanism, strong service processing capability, and excellent
expansibility. The NE40E is based on a 400G platform and provides 100G line cards to
satisfy increased demand for bandwidth. Compatible with all line cards currently in use,
the NE40E minimizes the need for additional investments.
Ordering
NE40E Router Configuration Flow: Basic Configuration -》Services Boards–》Special
Service Boards–》Software, License–》Electrical or Optical Modules –》Cabinet –》
Cables –》Accessories
1 Basic Configuration
1)Chassis(with power):Select a chassis based on the number of service boards
required.
BOM Number SBOM Type Description Main
Control
Switc
hing
Servic
e
Slots
Power
Slots
Maximum Power
Consumption
02351596
CR52-BKPE-4
U-DC
NetEngine40E-X3,C
R5Z1BKPE,Integrate
d DC Chassis
Components(NE40E
-X3)-4U 1+1
Backup
In the
chass
is, no
need
to
config
ure
3 2
<=1100W
02351597
CR52-BKPE-5
U-AC
NetEngine40E-X3,C
R5Z2BKPE,Integrate
d AC Chassis
Components(NE40E
-X3)-5U
<=1100W
02351930
CR5B0BKP08
70
NetEngine40E,CR5Z
1BKP08A,NE40E-X8
Integrated Chassis
Components(Includi
ng 4 DC Power)
1+1
Backup
1
8 4
<=3300W
02351931
CR5B0BKP16
70
NetEngine40E,CR5Z
1BKP16A,NE40E-X1
6 Integrated Chassis
Components(Includi
ng 8 DC Power)-32U
1+1
Backup
4
16 8
<=6500W
02400376 CR5B0PWRB
X60
Power Distribution Cabinet,220V,50/60HZ,72000mA,None,EPS200-4850A
NE40E-X8/X16 AC must configure,1 for X8,2 for X16
02130872 WPSU50A00 Power module--33degC-65degC-90VAC-290VAC-(-53.5)VDC/54.2A-AC/DC rectifier
NE40E-X8/X16 AC must configure,4 for X8,8 for X16
04080076 None Monitor and Alarm Cable,3m,D9M,CC4P0.48B(S),D9M
NE40E-X8/X16 AC must configure,1 for X8,2 for X16
2)Main control and SFU:Select a main control board according to the chassis,
bandwidth and backup requirements.
BOM
Number
SBOM Type Description Applicable
Chassis
Backup Remarks
03030KKR
CR52-MPUD
NetEngine40E,CR5
2MPUD0,Main
Processing Unit
D(Including 1*2G
Memory and 1*1G
CF Card)
NE40E-X3
1:1 Mandatory and not preferred.
Each device is configured with
one MPUD or two MPUDs.
Memory cards and CF cards need
to be prepared additionally. Each
MPUD can be configured with two
CF cards and one DDR2 memory
card.
03054206
CR5D0MPUD
170
NetEngine40E,CR5
2MPUD2,Main
Processing Unit
D2(Including 2G
Memory and 2G
USB)
NE40E-X3
1:1 Mandatory and preferred. Each
device is configured with 1 or 2
pcs. It contains a 2 G DDR3
memory card and a 2 G EUSB,
which are not quoted
independently. It is supported only
in V6R5C00 and later versions.
03030KSR
CR5D0SRUA4
70
NetEngine40E,CR5
7SRU40A4,Switch
and Route
Processing Unit
NE40E-X8
1:1 Not preferred. It supports only 40
G LPUs. Each device is
configured with one or two pcs. It
can be configured with two CF
A4(Including 1*2G
Memory and 1*1G
CF Card)
cards, two DDR2 memory cards,
and two USB disks. By default, it
contains one 1 GB CF card and
one 2 GB memory card. The other
CF card, memory card, and USB
disks need to be prepared and
quoted additionally.
03053549
CR5D0SRUA5
70
NetEngine40E,CR5
7SRU200A5,Switch
and Route
Processing Unit
A5(Including One
2G Memory and
One 1G CF Card)
NE40E-X8
1:1 Preferred. It is optional for
supporting 100 Gbit/s LPUs and
supported in V600R003 or later
versions. Each device is equipped
with one or two pcs. It can be
configured with two CF cards, two
DDR2 memory cards, and two
USB disks. By default, it contains
one 1 GB CF card and one 2 GB
memory card. The other CF cards,
memory card, and USB disks
need to be prepared and quoted
additionally.
03030KSY CR5DSFUI407
C
NetEngine40E-CR5
7SFU40C0-40Gbps
Switch Fabric Unit C
NE40E-X8
2+1
Not preferred
03053548
CR5DSFUIE0
7C
NetEngine40E-CR5
7SFU200C0-200Gb
ps Switch Fabric
Unit C
NE40E-X8
2+1 Preferred. It is used to replace the
SFU with the BOM number as
03030KSY.
03030JTW
CR5D0MPUB
460
NetEngine40E,CR5
6MPUB4,Main
Processing Unit
B4(Including 1*2G
Memory and 1*1G
CF Card)
NE40E-X1
6
1:1 Mandatory and preferred. Each
device is configured with one
MPUD or two MPUB4s. Each
MPUB4 can be configured with
two CF cards, two DDR2 memory
cards, and two USB disks. By
default, each MPUB4 is attached
with one 1 GB CF card and one 2
GB memory card. The other CF
card, memory card, and USB
disks need to be prepared and
quoted additionally.
03030KSX CR5DSFUI407
B
NetEngine40E-CR5
7SFU40C0-40Gbps
Switch Fabric Unit B
NE40E-X1
6
3+1
Not preferred
03053547 CR5DSFUIE0
7B
NetEngine40E-CR5
7SFU200B0-200Gb
NE40E-X1
6
3+1 Preferred. It is used to replace the
03030KSX. It is optional for
ps Switch Fabric
Unit B
supporting 100 Gbit/s LPUs and
mandatory for supporting 200
Gbit/s LPUs. It is used together
with the SRU200A5 and
supported in V600R003C00 or a
later version.
3)CF Card, Memory card and USB Disks
Configuration notes of the CF card, memory card and USB disks:
BOM Number SBOM Type Model Description Remarks
02315064 CF-512M CF Card 512 MB CF card Mandatory.
02316042 CF-1G CF Card 1 GB CF card Mandatory.
02315063 MEM-1G-184pin Memory
Card
MEM-1G-184pin It is mandatory and of DDR
SDRAM type. This type of
memory cards is applied to
the MPUs on the NE40E-X3
and NE40E-X16 and SRU on
the NE40E-X8.
02316431 MEM-2G-240pin Memory
Card
2GB 240pin memory module
It is mandatory and of DDR2
SDRAM type. This type of
memory cards is applied to
the MPUs on the NE40E-X3
and NE40E-X16 and SRU on
the NE40E-X8.
06010171 NUSBDSK01 USB Disk Storage, USB
disk,4GB/USB2.0
Optional. It is applied to the
SRU40A4 on the NE40E-X8
and the MPUB4 of the
NE40E-X16.
NE40E-X3
The CR52MPUD (03030KKR) of the NE40E-X3 can be configured with two CF cards
and the maximum capacity of a single CF card can be 1 GB.
By default, the CR52MPUD is already attached with one 1 GB CF card. During
configuration, you must configure another CF card. The CF card with the BOM number
being 02316042 is recommended.
The CR52MPUD2 contains CF cards. Customers do not need to purchase
additionally.
The CR52MPUD (03030KKR) of the NE40E-X3 has one memory slot and supports
single DDR2 memory cards of a maximum of 2 GB.
By default, the CR52MPUD is already attached with a 2 GB memory card. You do not
need to purchase the memory card independently during the contract configuration.
The CR52MPUD2 contains 2 GB DDR3 memory cards. Customers do not need to
purchase additionally.
CR52-MPUD does not support USB disks. CR5D0MPUD170 supports 2G USB and it
is contained and need not to be configured.
NE40E-X8
The CR57SRU40A4 (03030KSR) of the NE40E-X8 can be configured with two CF
cards and the maximum capacity of a single CF card can be 1 GB.
By default, the CR57SRU40A4 is already attached with one 1 GB CF card. During
configuration, you must configure another CF card. The CF card with the BOM number
being 02316042 is recommended.
he CR57SRU40A4 (03030KSR) of the NE40E-X8 supports 2 GB DDR2 SDRAM
memory cards and can be configured with a maximum of two such memory cards. The
CR57SRU40A4 is already attached with one 2 GB memory card.
It is recommended that the CR57SRU40A4 be configured with another memory card
of the BOM number 02316431 during the contract configuration.
The CR57SRU40A4 (03030KSR) of the NE40E-X8 supports two USB2.0 interfaces.
Each SRU40A4 supports a maximum of two USB disks, and each NE40E-X8 supports a
maximum of four USB disks. By default, no USB disk is configured. How many USB disks
(06010161 or 06010171) needs to be configured depend on customers' requirements.
The USB disk is used to upgrade the system software package. It is recommended that
each device be configured with one USB disk. After the upgrade, you need to copy the
system software package to the CF card.
NE40E-X16
The CR56MPUB4 (03030JTW) of the NE40E-X16 can be configured with two CF
cards and the maximum capacity of a single CF card can be 1 GB.
By default, the CR56MPUB4 is already attached with one l GB CF card. During
configuration, you must configure another CF card. The CF card with the BOM number as
02316042 is recommended.
The CR56MPUB4 (03030JTW) of the NE40E-X16 supports 2 GB DDR2 SDRAM
memory cards and can be configured with a maximum of two such memory cards. The
CR56MPUB4 is already attached with one 2 GB memory card.
It is recommended that the CR56MPUB4 be configured with another memory card of
the BOM number 02316431 during the contract configuration.
In 1:1 mode of MPUs or SRUs, the capacity of the memory cards of the MPUs or
SRUs must be the same. The memory cards configured for one board must share the
same BOM number, and it is better to have them supplied by the same manufacturer.
The CR56MPUB4 (03030JTW) of the NE40E-X16 supports two USB2.0 interfaces.
Each MPUB4 supports a maximum of two USB disks, and each NE40E-X16 supports a
maximum of four USB disks. By default, no USB disk is configured. You can determine the
number of USB disks with the BOM number being 06010161 or 06010171 according to
customers' requirements. The USB disk is used to upgrade the system software package.
It is recommended that each device be configured with one USB disk. After the upgrade,
you need to copy the system software package to the CF card.
2 Service Slots
1)Configuration Notes of the LPUF-10: The LPUF-10 (03038461) is a 10 Gbit/s
platform for flexible cards. It provides four slots for flexible cards of the same type or
different types, and supports hot swap of flexible cards. The LPUF-10 supports a
maximum of 10-Gbit/s bandwidth. When the total bandwidth of ports in the four slots
exceeds 10 Gbit/s, the line-rate forwarding performance is not ensured.
BOM Number SBOM Type Description Remarks
03038461 CR53-LPUF-10 Flexible Card Line Processing Unit(LPUF-10,four slots)
The LPUF-10 (03038461) is a 10 Gbit/s platform for flexible cards. It provides four slots for flexible cards of the same type or
different types, and supports hot swap of flexible cards.
03030FSL CR53-P10-1xPOS/STM64-XFP
1-Port OC-192c/STM-64c POS-XFP Flexible Card(Occupy two slots)
Each flexible card occupies two subcard slots on the LPUF-10. It is strongly recommended that only P1XX be configured for each LPUF-10. The XFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of one XFP optical module.
03030EYA CR53-P10-8x100/1000Base-X-SFP
8-Port 100/1000Base-X-SFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-10.
The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of eight SFP optical modules. All interfaces support the sending of Ethernet synchronous clock signals and meanwhile only the interface 0/1 supports the receiving of Ethernet synchronous clock signals.
SFP optical modules with electrical interfaces can be inserted into the interfaces of each flexible card.
03030GBV CR53-P10-1xPOS/STM16-SFP
1-Port OC-48c/STM-16c POS-SFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-10.
The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of one SFP optical module.
03030GUG CR53-P10-2xATM/STM4-SFP
2-Port OC-12c/STM-4c ATM-SFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-10.
The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of two SFP optical modules.
03030GBR CR53-P10-4xATM/STM1-SFP
4-Port OC-3c/STM-1c ATM-SFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-10.
The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of four SFP optical modules.
03030HNJ CR53-P10-2xPOS/STM16-SFP
2-port OC-48c/STM-16c POS-SFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of two SFP optical modules.
03030JCX CR53-P10-4xPOS/STM16-SFP
4-port OC-48c/STM-16c POS-SFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-10.
The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of four SFP optical modules.
03030JCY CR53-P10-4xPOS/STM4-SFP
4-port OC-12c/STM-4c POS-SFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-10.
The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of four
SFP optical modules.
03030JTY CR53-P10-4xPOS/STM1-SFP
4-port OC-3c/STM-1c POS-SFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-10.
The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of four SFP optical modules.
03030JUB CR53-P10-8xPOS/STM4-SFP
8-port OC-12c/STM-4c POS-SFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-10.
The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of eight SFP optical modules.
03030JUA CR53-P10-8xPOS/STM1-SFP
8-port OC-3c/STM-1c POS-SFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-10.
The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of eight SFP optical modules.
03030KBB CR53-P10-2xcPOS/STM1-SFP
2-Port Channelized OC-3c/STM-1c POS-SFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-10.
The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of two SFP optical modules.
03030HNE CR53-P10-4xE3/cT3-SMB
4-Port Clear Channel E3/Channelized T3-SMB Flexible Card
Each flexible card occupies one subcard slot on the LPUF-10.
Coaxial cables are used as user cables.
03030KHP CR53-P10-24xcE1/cT1-DB100
24-Port Channelized E1/T1-DB100 Flexible Card (Supporting 1588v2)
Each flexible card occupies one subcard slot on the LPUF-10 and needs to be connected to a conversion box through the cable (04070064). If the cable is a coaxial cable with SMB connectors, the conversion box (02351608) is used. If the cable is a twisted-pair cable with RJ48 connectors, the conversion box (02351606 or 02351607) is used.
03030KNE CR5M0E8GFA30 8-Port 100/1000Base-X-SFP Flexible Card A(P10-A,Supporting 1588v2)
Each flexible card occupies one subcard slot on the LPUF-10.
The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of eight SFP optical modules.
SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card.
In addition to IEEE 1588v2, all interfaces support the sending and receiving of Ethernet synchronous clock signals.
02351606 DB100-24xRJ48-E1/T1-Box
24*E1/T1 DB100 to RJ48 Port Conversion Box
Each flexible card (03030KHP) is configured with one conversion box.
02351607 DB100-48xRJ48-E1/T1-Box
48*E1/T1 DB100 to RJ48 Port Conversion Box
Every two flexible cards (03030KHP) are configured with one conversion box.
02351608 DB100-24xSMB-E 24*E1 DB100 to SMB Port Each flexible card (03030KHP) is
1-Box Conversion Box configured with one conversion box.
04070064 DB100-DB100-Cable-4m
Signal cable ,24E1 Transit Cable,4m,D100M-I,3*CC16P0.4P430U(S)-I,D100M-I
Each flexible card (03030KHP) is configured with one cable.
2)Configuration Notes of the LPUF-21: The LPUF-20 and LPUF-21 are newly
increased in NE80E/40E V300R003. Adopting the SD588 processors, the LPUF-20 and
LPUF-21 are 20 Gbit/s platforms for flexible cards and support a maximum bandwidth of
20 Gbit/s. When the total bandwidth of the interfaces on the LPUF-20 and LPUF-21 in two
slots exceeds 20 Gbit/s, the line-rate forwarding performance is not ensured on all
interfaces. The LPUF-20/21 provides two slots for flexible cards of the same type or
different types. According to the support for hot swap of the flexible card, the LPUF-20 can
be classified into the LPUF-20 supporting hot swap (03030HVN and 02316416) and the
LPUF-20 that does not support hot swap (02315504 and 02315756). The LPUF-21
supports hot swap of the flexible card.
In the case of the LPUF-20 that does not support hot swap of the flexible card, before
installing the LPUF-20, you need to first insert flexible cards into the LPUF-20, and before
removing flexible cards, you need to first remove the LPUF-20. In the case of the LPUF-20
that supports hot swap of the flexible card and the LPUF-21, you can install the
LPUF-20/21 and insert or remove the flexible cards in any order. The LPUF-20/-21-A
supports services such as L3VPN, MVPN, and enhanced IPV6.
BOM Number SBOM Type Description Remarks
03030KJY CR52-LPUF-21-A Flexible Card Line Processing Unit(LPUF-21,2 sub-slots) A (L3VPN,MVPN,IPV6 Enhanced)
Supports hot swap of the flexible card and is preferred.
Supports services such as L3VPN, MVPN, and enhanced IPV6.
Supports full-width and half-width flexible cards.
03053989 CR5DLPUF202E Flexible Card Line Processing Unit(LPUF-21,2 sub-slots) E
Supports hot swap of subcards.
Supports services such as L3VPN, MVPN, and IPV6 enhanced.
Supports both half-width subcards and full-width subcards.
Supports the traffic management function.
Supports PPPoE users’ access.
The board is supported since V600R005C00.
03030GSG CR52-P20-12x10/100/1000Base-TX-RJ45
12-Port 10/100/1000Base-RJ45 Flexible Card
Each flexible card occupies one subcard slot on the LPUF-20/21.
03030GSK CR52-P20-1x10GBase WAN/LAN-XFP
1-Port 10GBase WAN/LAN-XFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-20/21.
The XFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of one XFP optical module.
It supports the sending and receiving of
Ethernet synchronous clock signals.
03030GSH CR52-P20-12x100/1000Base-X-SFP
12-Port 100/1000Base-SFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-20/21.
The SFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of 12 optical modules. All interfaces support the sending of Ethernet synchronous clock signals and meanwhile only the interface 0/1 supports the receiving of Ethernet synchronous clock signals.
SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card.
03030HND CR52-P20-1xPOS/STM64-XFP
1-Port OC-192c/STM-64c POS-XFP Flexible Card
Each flexible card occupies one subcard slot on the LPUF-20/21.
The XFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of one XFP optical module.
03030JUJ CR52-P21-40x10/100/1000Base-TX-RJ45
40-Port 10/100/1000Base-RJ45 Flexible Card(Occupy two sub-slots)
It can be inserted into only the LPUF-21 and each flexible card occupies two subcard slots on the LPUF-21.
03030JUL CR52-P21-40x100/1000Base-X-SFP
40-Port 100/1000Base-SFP Flexible Card(Occupy two sub-slots)
It can be inserted into only the LPUF-21 and each flexible card occupies two subcard slots on the LPUF-21.
The SFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of 40 SFP optical modules. All interfaces of the flexible card support the sending of Ethernet synchronous clock signals but each time only one interface supports the receiving of Ethernet synchronous clock signals. The interface supporting the receiving of Ethernet synchronous clock signals is selected through software among the 40 interfaces on the flexible card.
SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card.
03030JUK CR52-P21-4x10GBase WAN/LAN-XFP
4-port 10GBase WAN/LAN-XFP Flexible Card(Occupy two sub-slots)
It can be inserted into only the LPUF-21 and each flexible card occupies two subcard slots on the LPUF-21.
The XFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of four XFP optical modules. All interfaces of the flexible card support the sending of Ethernet synchronous clock signals but each time only one interface supports the receiving of Ethernet synchronous clock signals. The interface supporting the receiving of Ethernet synchronous clock signals is selected
through software among the four interfaces on the flexible card.
03030FDY CR52-P20-48x10/100Base-TX-RJ45
2-Port 10GBase LAN/WAN-XFP+20-Port 100/1000Base-X-SFP Flexible Card(P20,Occupy two sub-slots)
It can be inserted into only the LPUF-21 and each flexible card occupies two subcard slots on the LPUF-21.
The XFP and SFP optical modules need to be prepared additionally and each LPUF-20/21 can be configured with a maximum of 2 XFP optical modules and 20 SFP optical modules.
All interfaces support the sending of Ethernet synchronous clocks and meanwhile only one interface supports the receiving of Ethernet synchronous clocks through software.
SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card.
03030KKP CR52-P20-12x100/1000Base-X-SFP-A
1-Port 10GBase WAN/LAN-XFP Flexible Card A(Supporting 1588v2)
Each flexible card occupies one subcard slot on the LPUF-20/21. Interfaces on the flexible card support the sending and receiving of Ethernet synchronous clocks and IEEE 1588v2. The XFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of one XFP optical module.
03030KKQ CR5ML2XEEG20 12-Port 100/1000Base-SFP Flexible Card A(Supporting 1588v2)
Each flexible card occupies one subcard slot on the LPUF-20/21.
The SFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of 12 SFP optical modules. SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card.
All interfaces support the sending of Ethernet synchronous clocks and meanwhile only one interface supports the receiving of Ethernet synchronous clocks through software.
All interfaces support IEEE 1588v2.
03030HVJ CR5M0EBGFB20
12-Port 100/1000Base-X-SFP Flexible Card B(P20-B)
Each flexible card occupies one subcard slot on the LPUF-21 and supports PPPoE and IPoE. The SFP optical module needs to be prepared additionally and each LPUF-21 can be configured with a maximum of 12 SFP optical modules. SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card.
03030HVH CR5M0L1XXB20
1-Port 10GBase LAN/WAN-XFP Flexible Card B(P20-B)
Each flexible card occupies one subcard slot on the LPUF-21 and supports PPPoE and IPoE. The XFP optical module needs to be prepared additionally and each LPUF-21 can be configured with a maximum of one XFP optical module.
03030LVG CR5M0L1XXE20
1-Port 10GBase LAN/WAN-XFP Flexible Card E(P20-E)
Each flexible card occupies one subcard slot on the LPUF-21 and supports downstream TM. The XFP optical module needs to be prepared additionally and each LPUF-21 can be configured with a maximum of one XFP optical module.
03030LVF CR5M0EAGFE20
10-Port 1000Base-X-SFP Flexible Card E(P20-E)
Each flexible card occupies one subcard slot on the LPUF-21 and supports downstream TM.
The XFP optical module needs to be prepared additionally and each LPUF-21 can be configured with a maximum of 10 XFP optical modules. XFP optical modules with 1000M electrical interfaces can be inserted into the interfaces of each flexible card.
3)Configuration Notes of the LPUF-40: The LPUF-40 is a 40 Gbit/s platform for flexible
cards and supports a maximum bandwidth of 40 Gbit/s. The LPUF-40 provides two slots
for flexible cards of the same type or different types, and supports hot swap of the flexible
card.
The LPUF-40-A supports services such as L3VPN, MVPN, and enhanced IPV6.
BOM Number SBOM Type Description Remarks
03030KWD
CR5MLPUF402A
Flexible Card Line Processing Unit(LPUF-40,2 sub-slots) A (L3VPN,MVPN,IPv6 Enhanced)
Supports hot swap of the flexible card and is preferred.
Supports services such as L3VPN, MVPN, and enhanced IPV6.
03053990
CR5DLPUF402E
Flexible Card Line Processing Unit(LPUF-40,2 sub-slots) E
Supports hot swap of subcards.
Supports services such as L3VPN, MVPN, and IPV6 enhanced.
Supports the traffic management function.
Supports PPPoE users’ access.
The board is supported since V600R005C00.
03036967 CR5M00EEGF20 20-Port 100/1000Base-X-SFP Flexible Card(P40)
Each flexible card occupies one subcard slot on the LPUF-40.
All interfaces support the sending of Ethernet synchronous clocks and meanwhile only one interface supports the receiving of Ethernet synchronous clocks through software.
The SFP optical module needs to be prepared additionally and each LPUF-40 can be configured with a maximum of 20 SFP optical modules.
SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card.
The 100M SFP optical module is supported and a maximum of 20 100M SFP optical modules can be inserted into
each flexible card.
03037070 CR5M0EEGFA20 20-Port 100/1000Base-X-SFP Flexible Card A(P40-A,Supporting 1588v2)
Each flexible card occupies one subcard slot on the LPUF-40.
All interfaces support the sending of Ethernet synchronous clocks and meanwhile only one interface supports the receiving of Ethernet synchronous clocks through software.
The SFP optical module needs to be prepared additionally and each LPUF-40 can be configured with a maximum of 20 SFP optical modules.
SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card. All interfaces on the flexible card support IEEE 1588v2.
The 100M SFP optical module is supported and a maximum of 20 100M SFP optical modules can be inserted into each flexible card.
03036752 CR5M00L2XX20 2-Port 10GBase LAN/WAN-XFP Flexible Card(P40)
Each flexible card occupies one subcard slot on the LPUF-40.
All interfaces support the sending of Ethernet synchronous clocks and meanwhile only one interface supports the receiving of Ethernet synchronous clocks through software.
The XFP optical module needs to be prepared additionally and each LPUF-40 can be configured with a maximum of two XFP optical modules.
03038466 CR5M0L2XXA20 2-Port 10GBase LAN/WAN-XFP Flexible Card A(P40-A,Supporting 1588v2)
Each flexible card occupies one subcard slot on the LPUF-40.
All interfaces support the sending of Ethernet synchronous clocks and meanwhile only one interface supports the receiving of Ethernet synchronous clocks through software.
The XFP optical module needs to be prepared additionally and each LPUF-40 can be configured with a maximum of two XFP optical modules.
All interfaces on the flexible card support IEEE 1588v2.
03030MDK CR5M0L2XXB20 2-Port 10GBase LAN/WAN-XFP Flexible Card B(P40-B,Supporting PPPoE and IPoE)
Each flexible card occupies one subcard slot on the LPUF-40 and supports PPPoE and IPoE.
The XFP optical module needs to be prepared additionally and each LPUF-40 can be configured with a maximum of two XFP optical modules.
The flexible card is supported in V600R002C02 and later versions.
03030MDS CR5M0EEGFB20 20-Port 100/1000Base-X-SFP Flexible Card B(P40-B,Supporting PPPoE
Each flexible card occupies one subcard slot on the LPUF-40 and supports PPPoE and IPoE.
The SFP optical module needs to be
and IPoE) prepared additionally and each LPUF-40 can be configured with a maximum of 20 SFP optical modules.
SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card.
The 100M SFP optical module is supported and a maximum of 20 100M SFP optical modules can be inserted into each flexible card.
The flexible card is supported in V600R002C02 and later versions.
03030MLA
CR5D00EEGE70
20-Port 10/100/1000Base-RJ45 Flexible Card(P40)
Each subcard requires an LPUF-40 subcard slot.
The board is supported by NE40E since V600R005C00.
03030LXH
CR5D00L4XX70
4-Port 10GBase LAN/WAN-XFP Flexible Card(P40,Occupy one sub-slot)
Each subcard requires an LPUF-40 subcard slot.
At most four XFP optical modules can be configured additionally for each card.
The board is supported by NE40E since V600R005C00.
03030LYU
CR5D0EEGFE70
20-Port 1000Base-X-SFP Flexible Card E(P40-E)
Each subcard requires an LPUF-40 subcard slot. Supports traffic control management.
The SFP optical module is required additionally. At most 20 SFP optical modules can be configured for each subcard.
SFP modules with electrical interfaces can be configured. SFP modules with 10M/100M/1000M electrical interfaces can be inserted into ports. The LPUF-40 board with 5A configuration can be equipped with 10 electrical interface SFP modules at most. The LPUF-40 board with 7A configuration supports full 20 electrical interface SFP modules.
The 100M SFP optical module is supported and each subcard can be installed with 20 100M SFP optical modules.
The board is supported by NE40E since V600R005C00.
03030MGC
CR5D0L2XXE70
2-Port 10GBase LAN/WAN-XFP Flexible Card E(P40-E)
Each subcard requires an LPUF-40 subcard slot. Supports traffic control management.
At most two XFP optical modules can be prepared additionally for each card.
The board is supported by NE40E since V600R005C00.
4)Configuration Notes of the LPUF-100: The LPUF-100 is a 100G flexible card platform
and supports a maximum bandwidth of 100 Gbit/s.The LPUF-100 provides four subcard
slots and supports the mixed configuration of subcards of various types. In addition, the
LPUF-10 supports hot swap of subcards.
The LPUF-100 supports services such as L3VPN, MVPN, and IPV6 enhanced.
BOM Number SBOM Type Description Remarks
03053589
CR5DLPUFA070
NetEngine40E,CR57LPUF101A0,100Gbps Flexible Card Line Processing Unit(LPUF-100,4 sub-slots)
Provides four subcard slots and supports the hot swap of subcards. Preferred;
Supports services such as L3VPN, MVPN, and IPV6 enhanced.
03030MXM
CR5D0L5XXA70
5-Port 10GBase LAN/WAN-XFP Flexible Card A(P100-A,Supporting 1588v2,Occupy two sub-slots)
It occupies two LPUF-100 subcard slots.
The XFP optical module is required additionally. At most five XFP optical modules can be installed on each board.
All interfaces support 1588v2.
The board is supported by NE40E since V600R003.
03030MXA CR5D00EMGF72 48-Port 100/1000Base-X-CSFP Flexible Card(P100,Occupy two sub-slots)
It occupies two LPUF-100 subcard slots.
The CSFP single-fiber bidirectional optical module(34060525)is required additionally. At most 24 CSFP single-fiber bidirectional optical modules can be installed on each board.
The board is supported by NE40E since V600R003.
03030NCF CR5D00EFGF70 24-Port 100/1000Base-X-SFP Flexible Card(P100,Occupy two sub-slots)
It occupies two LPUF-100 subcard slots.
The SFP optical module is required additionally. At most 24 SFP optical modules can be installed on each board.
SFP modules with 10M/100M/1000M electrical interfaces can be installed on the subcard.
Supported by V600R003 and later versions. The board is supported by NE40E since V600R003.
03030MXC CR5D0L5XFB70 5-Port 10GBase LAN/WAN-SFP+ Flexible Card B(P100-B,Occupy two sub-slots)
It occupies two LPUF-100 subcard slots.
SFP+ optical module is required additionally. At most five SFP+ optical modules can be installed on each board.
03030MXN CR5D00P1MZ70 1-Port OC-768c/STM-256c POS-2KM-LC Flexible Card(P100,2 sub-slots)
No need SFP modules.
03030MXQ CR5D00P2XX70 2-Port OC-192c/STM-64c POS-XFP Flexible Card(P100,Occupy one sub-slot)
It occupies one LPUF-100 subboard slot.
XFP optical modules need to be configured additionally and it can be equipped with a maximum of two XFP optical modules.
The subboard needs to be configured with guide rails and blank fillers.
BOM No. of the 1/4-width blank filler: 21136332
BOM number of the guide rail: 21122042
5)5.5.5 Configuration Notes of the LPUI: The integrated LPU is not a flexible LPU. The
integrated LPU includes the 100G LPUI-100 and 40G LPUI-41.
BOM Number SBOM Type Description Remarks
03053481 CR5D0LAXXA70 NetEngine40E,CR57L5XFA0,5-Port 10GBase LAN/WAN-SFP+ Flexible Card B(P100-B,Occupy two sub-slots)
The line-rate forwarding capability is 100 Gbit/s;
The XFP optical module is required additionally. At most 10 XFP optical modules can be installed on each board.
03053480 CR5D00EDXF70 NetEngine40E,CR57EDXFB0,16-Port 10GBase LAN-SFP+ Integrated Line Processing Unit (LPUI-100)
Converge the 160G board to the 80G board;
The SFP+ optical module is required additionally. At most 16 SFP+ optical modules can be installed on each board.
03053421 CR5D00L8XX70 NetEngine40E,CR57L8XXB0,8-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-41)
The line-rate forwarding capability is 40 Gbit/s;
The XFP optical module is required additionally. At most eight XFP optical modules can be installed on each board.
03053422 CR5D00L4XX71 NetEngine40E,CR57L4XXB0,4-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-41)
The line-rate forwarding capability is 40 Gbit/s;
The XFP optical module is required additionally. At most four XFP optical modules can be installed on each board.
03053423 CR5D00EMGF70 NetEngine40E,CR57EMGFB0,48-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-41)
The line-rate forwarding capability is 50 Gbit/s;
The SFP optical module is required additionally. At most 48 SFP optical modules can be installed on each board.
SFP modules with 10M/100M/1000M electrical interfaces can be installed on the subcard.
The CR57EMGFB0 supports 100M SFP optical modules and each board can be installed with 48 100M SFP optical modules.
03053420 CR5DL2XEFG70 NetEngine40E,CR57L2XEFGB0,2-Port 10GBase LAN/WAN-XFP+24-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-41)
The line-rate forwarding capability is 50 Gbit/s;
The XFP optical module is required additionally. At most two XFP optical modules can be installed on each board.
The SFP optical module is required additionally. At most 24 SFP optical modules can be installed on each board.
SFP modules with 10M/100M/1000M electrical interfaces can be installed on the subcard.
03053542 CR5D0L4XXA70 NetEngine40E,CR57L4XXC0,4-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-41,Supporting 1588v2)
The line-rate forwarding capability is 50 Gbit/s;
The XFP optical module is required additionally. At most four XFP optical modules can be installed on each board.
03053543 CR5D0EKGFA70 NetEngine40E,CR57EKGFC0,40-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-41,Supporting 1588v2)
The line-rate forwarding capability is 50 Gbit/s;The SFP optical module is required additionally. At most 40 SFP optical modules can be installed on each board.
SFP modules with 10M/100M/1000M electrical interfaces can be installed on the subcard.
03053544 CR5DL2XEEG7A NetEngine40E,CR57EKGFC0,40-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-41,Supporting 1588v2)
The line-rate forwarding capability is 50 Gbit/s;
The XFP optical module is required additionally. At most two XFP optical modules can be installed on each board.
The SFP optical module is required additionally. At most 20 SFP optical modules can be configured for each board.
SFP modules with 10M/100M/1000M electrical interfaces can be installed on the subcard.
The LPUI-100 can only be used on the NE40E-X8/X16, and must be used with the 200G
MPU and 200G SFU. CR5D0SRUA570(03053549) and CR5DSFUIE07C (03053548) are
needed on NE40E-X8; CR5DSFUIE07B (03053547) is needed on the NE40E-X16.
3 Special Service Boards
NE40E provides multiple types of services boards.
BOM Number SBOM Type Description Remarks
03030LXJ CR53-SPU-C NetEngine80E,CR53SPUCC0,Versatile Service Process Unit C
The SPU does not provide interfaces to connect to external interfaces. You can configure different licenses for different services.
03053128 CR5MVSUF1010 NetEngine80E, CR52VSUF10, Flexible Card Versatile Service Unit 10(VSUF-10)
The VSUF does not provide interfaces to connect to external interfaces. You can configure different licenses for different services. The flexible card is supported in V600R002C02 and later versions.
0305G062 CR5DVSUI201A (VSUI-20-A) The board is supported since V600R005C00.
4 Software, License
Description:Starting from V300R003, the NE40E/80E adopts the License-based sale
strategy. The general principle is as follows:
1. Base package
The base package is mandatory item to be purchased for the NE40E/80E of each version,
especially at a new site.
2. Feature license
Feature licenses are controlled and are sold according to the features required by
customers. Feature licenses of the NE40E/80E are classified into device licenses and
board licenses. For device licenses, each device needs to be configured with one device
license, for example, a 1588v2 Function License for the 1588v2 feature. For board
licenses, each board needs to be configured with one license, for example, the
LPUF-40-B Upgrade to LPUF-40-A License.
3. Upgrade fee
If customers attempt to upgrade the earlier versions to use new features, they need to pay
the upgrade fee. For upgrades on Huawei's account, such as bug fixing or contract
obligation, the upgrade fee is charged as required.
Software sale strategies may be adjusted. For detailed information about licenses on sale,
refer to the latest Quoter-d system.
BOM Number SBOM Type Description Remarks
88030YTE CR5S40BS6500 NetEngine40E&80E basic software,VRP5, V600R005
Must be purchased for a new site.
81400135 SWP-CR53LIC-V3R3Update SWP-CR53LIC-V3R3Update NetEngine80E/40E V300R003 upgrade
88030BUW CR5S40EF0000 CR5S40EF0000 Software enhancement fee for upgrading the NE40E/80E from Rn to R(n+1).
81400189 CR5S40CLCK00 NetEngine40E&80E 1588v2 Function License
It is a device license.
82400144 CR5S40BTOA00 NetEngine40E&80E LPUF-40-B Upgrade to LPUF-40-A License (L3VPN, Ability of MVPN, IPv6 Enhanced)
It is a board license.
82400189 SWP-CR52LIC-21BToA NetEngine80E/40E LPUF-21/20-B Upgrade to LPUF-21/20-A License (IPv6, L3VPN, MVPN)
It is a board license.
82400137 SWP-CR53LIC-NetStream-SPUC NetEngine80E/40E NetStream License for SPUC
Each SPUC requires one.
82400141 SWP-CR53LIC-MVPN-SPUC NetEngine80E/40E MVPN License for SPUC
Each SPUC requires one.
82400140 SWP-CR53LIC-Tunnel-SPUC NetEngine80E/40E Tunnel (GRE, Lawful interception, 4 over 6, etc.) License for SPUC
Each SPUC requires one.
82400204 CR5S40VIDE00 Resource, NetEngine40E&80E, LCR5VIDE00, NetEngine40E&80E Video Enhanced Function License
Each VSUF-10 requires one.
82400205 CR5S40SNAT00 NE40E&80E NAT License for SPUC
Each SPUC requires one.
81400208 CR5S40MHAG00 NE40E&80E Cross-chassis HAG Function License
It is a device license.
82400207 CR5S40BRAS00 NE40E&80E PPPoE/IPoE Function License for LPUF-21
Each LPUF-21 requires one.
82400208 CR5S40BRAS01 NE40E&80E PPPoE/IPoE Function License for LPUF-40
Each LPUF-40 requires one.
81400210 CR5S40L2TP00 NetEngine40E&80E L2TP Function License
It is a device license.
81400281 CR5S4000LI00 NetEngine40E&80E Lawful Interception Function License
It is a device license.
81400279 CR5S400DAA00 NetEngine40E&80E DAA Function License
It is a device license.
81400285 CR5S400MDI00 NetEngine40E&80E Video Monitoring Function License
It is a device license.
82400240 CR5S40NATS00 NetEngine40E&80E 2M NAT Session License
It is a device license.
82400220 CR5S400DPI00 NetEngine40E&80E DPI Function License for VSUF-10
Each VSUF-10 requires one
82400247 CR5S40DUAF00 NetEngine40E&80E DPI Signature Database Upgrading Annual Fee
It is a device license.
5 Electrical or Optical Modules
NE40E provides multi electrical and optical Modules.
Bom Description Mode Remarks
34060287
Optical Transceiver,SFP,1310nm,STM1,-19~-14dBm,-30dBm,LC,MM,2km
Multimode
Recommended
34060276
Optical Transceiver,eSFP,1310nm,STM1,-15~-8dBm,-31dBm,LC,SM,15km
Single mode
Recommended
34060281
Optical Transceiver,eSFP,1310nm,STM1,-5~0dBm,-37dBm,LC,SM,40km
Single mode
Recommended
34060282
Optical Transceiver,eSFP,1550nm,STM1,-5~0dBm,-37dBm,LC,SM,80km
Single mode
Recommended
34060287
Optical Transceiver,SFP,1310nm,STM1,-19~-14dBm,-30dBm,LC,MM,2km
Multimode
Recommended
34060299
Optical Transceiver,eSFP,1310nm,STM1,-15~-8dBm,-31dBm,LC,SM,15km
Single mode
Recommended
34060300
Optical Transceiver,eSFP,1310nm,STM1,-5~0dBm,-37dBm,LC,SM,40km
Single mode
Recommended
34060301
Optical Transceiver,eSFP,1550nm,STM1,-5~0dBm,-37dBm,LC,SM,80km
Single mode
Recommended
34060555
BiDi Transceiver,CSFP,1550(Tx) / 1310(Rx)nm,125~155Mbps,-14dBm,-8dBm,-28.2dBm,LC,SM,10km
Single mode
Recommended
34060302
Optical Transceiver,eSFP,1310nm,STM4,-15~-8dBm,-31dBm,LC,SM,15km
Single mode
Recommended
34060303
Optical Transceiver,eSFP,1310nm,STM4,-3~2dBm,-30dBm,LC,SM,40km
Single mode
Recommended
34060304
Optical Transceiver,eSFP,1550nm,STM4,-3~2dBm,-30dBm,LC,SM,80km
Single mode
Recommended
34060286
Optical Transceiver,eSFP,850nm,2.125Gb/s(Multi rate) ,-9.5~-2.5dBm,-17dBm,LC,MM,0.5km
Multi-mode
Recommended
34060219
Optical transceiver,eSFP,1310nm,1.25Gb/s,-9.5~-3dBm,-20dBm,LC,SM,10km
Single mode
Sales restricted
34060298
Optical Transceiver,eSFP,1310nm,1.25Gb/s,-5~0dBm,-23dBm,LC,SM,40km
Single mode
Recommended
34060069
Optical Transceiver,SFP,1550nm,1.25Gb/s,1dBm,-4dBm,-21dBm,LC(-40~85),40km
Single mode
Recommended
34060274
Optical Transceiver,eSFP,1550nm,1.25Gb/s,-2~5dBm,-23dBm,LC,SM,80km
Single mode
Sales restricted
34060295
Optical Transceiver,eSFP,1550nm,1.25Gb/s,0~5dBm,-30dBm,LC,SM,100km
Single mode
Recommended
34100080
Optical Function Module,1000BASE-T,RJ45 Electrical Interface SFP Module, Auto Negotiate, Maximum Transmission Distance 100m
Recommended
34060473
Optical transceiver,eSFP,1310nm,1.25Gb/s,-9~-3dBm,-20dBm,LC,Single Mode,10km
Single mode
Recommended
34060360
Optical Transceiver,eSFP,1550nm,1.25Gb/s,-2~5dBm,-23dBm,LC,SM,80km
Single mode
Recommended
34060351
Optical transceiver,eSFP,1471nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Single mode
34060350
Optical transceiver,eSFP,1491nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Single mode
34060315
Optical transceiver,eSFP,1511nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Single mode
34060332
Optical transceiver,eSFP,1531nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Single mode
34060346
Optical transceiver,eSFP,1551nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Single mode
34060347
Optical transceiver,eSFP,1571nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Single mode
34060348
Optical transceiver,eSFP,1591nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Single mode
34060349
Optical transceiver,eSFP,1611nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Single mode
34100080
Optical Function Module,1000BASE-T,RJ45 Electrical Interface SFP Module, Auto Negotiate, Maximum Transmission Distance 100m
RJ45 Recommended
34060470
Optical Transceiver,ESFP,Tx1310/Rx1490,1.25Gb/s,-3dBm,-9dBm,-19.5dBm,LC,Single Mode,10km
Single mode
It must be used with the optical module with the BOM number being 34060475.
34060475
Optical Transceiver,ESFP,Tx1490/Rx1310,1.25Gb/s,-3dBm,-9dBm,-19.5dBm,LC,Single Mode,10km
Single mode
It must be used with the optical module with the BOM number being 34060470.
34060525
Integrated Optical Transmitting and Receiving Module,CSFP,Transmitting:1490nm,Receiving:1310nm,1.25Gb/s,-9.0dBm,-3.0dBm,-19.5dBm,LC,10km
Single mode
It must be used with the optical module with the BOM number 34060470.
34060288
Optical Transceiver,eSFP,1310nm,STM16,-10~-3dBm,-21dBm,LC,SM,2km
Single mode
Recommended
34060278
Optical Transceiver,eSFP,1310nm,STM16,-5~0dBm,-21dBm,LC,SM,15km
Single mode
Recommended
34060289
Optical Transceiver,eSFP,1310nm,STM16,-2~3dBm,-29dBm,LC,SM,40km
Single mode
Recommended
34060279
Optical Transceiver,eSFP,1550nm,STM16,-2~3dBm,-30dBm,LC,SM,80km
Single mode
Sales restricted.
34060488
Optical Transceiver,eSFP,1550nm,STM16,-2~3dBm,-30dBm,LC,SM,80km
Single mode
Recommended
34060362
Optical Transceiver,XFP,850nm,10.3Gb/s,-7.3dBm,-1.3dBm,-7.5dBm,LC,MM,0.3km
Multimode
Applied to the 10 GBase LAN only
34060313
Optical Transceiver,XFP,1310nm,9.95~10.71Gb/s,-6dBm~-1dBm,-14.4dBm,LC,SM,10km
Single mode
Applied to the 10 G POS, 10 GBase LAN, and 10 GBase WAN
34060322
Optical Transceiver,XFP,1550nm,9.95Gb/s to 11.1Gb/s,+2dBm,-1dBm,-15dBm,LC,Single-mode,40km
Single mode
Applied to the 10 G POS, 10 GBase LAN, and 10 GBase WAN
34060361
Optical transceiver,XFP,1550nm,9.95Gb/s to 11.1Gb/s,0~4dBm,-24dBm,LC,Single-mode,80km
Single mode
Applied to the 10 G POS, 10 GBase LAN, and 10 GBase WAN
34060494
XFP|SFP+ Optical transceiver,SFP+,850nm,10Gb/s,-7.3~-1dBm,-11.1dBm,LC, MM,0.3km
Multi-mode
Can only be used in the 10GBase LAN.
3406049 XFP|SFP+ Optical Single Can only be
5 transceiver,SFP+,1310nm,10Gb/s,-8.2~0.5dBm,-12.6dBm,LC,SM,10km
mode used in the 10GBase LAN.
34060518
XFP|SFP+ Optical transceiver,SFP+,1550nm,9.95~11.1Gb/s,-4.7~4dBm,-14.1dBm,LC,SM,40km
Single mode
Can be used in the 10G POS, 10GBase LAN, and 10GBase WAN..
34060570
High Speed Transceiver,CFP-1295nm 1300nm 1304nm 1309nm-103.125Gbps--4.3dBm-4.5dBm--8.6dBm-SC-SMF-10km
single-mode
Can only be used in 10GBase-CFP interfaces..
6 Combinet
1) Combinet : An assembly cabinet is optional. According to customers'
requirements, an NE40E/80E can be installed in an assembly cabinet or in the
cabinet provided by the customer, or directly used without being installed in a
cabinet.
BOM SBOM Type Description Remarks
02113041 CR52-22-D NE80E,CR5B2N68E,2. 2m Router Assembly Cabinet with Double Swing Doors,N68E-22
Applicable for NE40E-X3, NE40E-X16, and NE40E-X8
7 External Cable Suites
1) Configuration Notes of Power Cables
Configuration notes of external cables and terminals of the NEPS3000-D
Length in Site Survey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Equal to or shorter than 25 m
25030101 Wire,450/750V,227 IEC 02(RV)25mm^2,Blue,110A
Each power module is equipped with one cable of this type. The cable length is determined by the site survey result.
25030432 Wire,450/750V,227 IEC 02(RV),25mm^2,Black,110A
Each power module is equipped with one cable of this type. The cable length is determined by the site survey result.
14170121 Naked Crimping connector,JG2,25mm^2,M8,150A,Silver Plated
Each cable is equipped with one terminal of this type, which is used to connect to the power module.
14170060 Naked Crimping Terminal,OT,25mm^2,M8,Tin
Each cable is equipped with one terminal of this type, which is
Length in Site Survey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Plating,Naked Ring Terminal used to connect to the power distribution frame.
Longer than 25 m and equal to or shorter than 35 m
25030199 Wire,450/750V,227 IEC 02(RV),35mm^2,Blue,135A
Each power module is equipped with one cable of this type. The cable length is determined by the site survey result.
25030420 Wire,450/750V,227 IEC 02(RV),35mm^2,Black,135A
Each power module is equipped with one cable of this type. The cable length is determined by the site survey result.
14170128 Naked Crimping Connector,JG2,35mm^2,M8,210A,Tin Plating,For OEM
Each cable is equipped with one terminal of this type, which is used to connect to the power module.
14170063 Naked Crimping Terminal,OT,35mm^2,M8,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.
Longer than 35 m A power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables and terminals of the NEPS5000-D
Length in the Site Survey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Equal to or shorter than 25 m
25030430 Wire,450/750V,227 IEC 02(RV),16mm^2,Blue,85A
Each power module is equipped with three cables of this type. The cable length is determined by the site survey result.
25030428 Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A
Each power module is equipped with three cables of this type. The cable length is determined by the site survey result.
14170020 Naked Crimping Terminal,OT,16mm^2,M6,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power module.
14170024 Naked Crimping Terminal,OT,16mm^2,M8,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.
Longer than 25 m and shorter than 35 m
25030101 Wire,450/750V,227 IEC 02(RV),25mm^2,Blue,110A
Each power module is equipped with three cables of this type. The cable length is determined by the site survey result.
25030432 Wire,450/750V,227 IEC 02(RV),25mm^2,Black,110A
Each power module is equipped with three cables of this type. The cable length is determined by the site survey result.
14170147 Naked Crimping Terminal,OT,25mm^2,M6,Tin Plating,Width Less Than 12.4mm,For OEM
Each cable is equipped with one terminal of this type, which is used to connect to the power module.
14170060 Naked Crimping Terminal,OT,25mm^2,M8,Tin
Each cable is equipped with one terminal of this type, which is used to connect to the
Plating,Naked Ring Terminal power distribution frame.
Longer than 35 m A power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables and terminals of the NEPS8000-D
Length in the Site Survey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Equal to or shorter than 25 m
25030430 Wire,450/750V,227 IEC 02(RV),16mm^2,Blue,85A
Each power module is equipped with three cables of this type. The cable length is determined by the site survey result.
25030428 Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A
Each power module is equipped with three cables of this type. The cable length is determined by the site survey result.
14170020 Naked Crimping Terminal,OT,16mm^2,M6,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power module.
14170024 Naked Crimping Terminal,OT,16mm^2,M8,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.
Longer than 25 m and shorter than 35 m
25030101 Wire,450/750V,227 IEC 02(RV),25mm^2,Blue,110A
Each power module is equipped with three cables of this type. The cable length is determined by the site survey result.
25030432 Wire,450/750V,227 IEC 02(RV),25mm^2,Black,110A
Each power module is equipped with three cables of this type. The cable length is determined by the site survey result.
14170147 Naked Crimping Terminal,OT,25mm^2,M6,Tin Plating,Width Less Than 12.4mm,For OEM
Each cable is equipped with one terminal of this type, which is used to connect to the power module.
14170060 Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.
Longer than 35 m A power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables and terminals of the AC power
NEPS3000-A
BOM Number Description Configuration Notes
25030422 Power Cable,300/500V,227IEC10(BVV),Black(Cores: Blue,Brown,Yellow/Green),36A,3*6mm^2
Each power module is equipped with one cable of this type. The cable length is determined by the site survey result.
14170013 Naked Crimping Terminal,OT,6mm^2,M8,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow
Each cable is equipped with three terminals of this type, which are used to connect to the power distribution frame.
14170017 Naked Crimping Terminal,OT,6mm^2,M4,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow
Each cable is equipped with three terminals of this type, which are used to connect to the power module.
Configuration notes of external cables and terminals of the AC power
NEPS5000-A
BOM Number Description Configuration Notes
25030463 Power Cable,300/500V,227IEC10(BVV),10mm^2,Black Jacket(Cores: Blue,Brown,Black,Yellow/Green),46A,4 Equivalent Cores
Each power module is equipped with one cable of this type, which is used to connect the AC power distribution frame and power distribution box.
04043396 Chinese AC Power Cable 220V16A,3m,3*2.5mm^2,Black,I-Type Angle Plug,227IEC53-2.5^2(3C),C19 Straight Connector
Each power module is equipped with three cables of this type, which are used to connect the power distribution box and the input terminal of the AC power module.
02120415 NetEngine5000E,CR5E3TSR,AC Distribution Frame for Cabinet,2 or 6 Input,6(2*3) Output,6 Group of 2 Poles 20A Air Switch
Each device is equipped with 1 pcs. The price of this item needs to be separately quoted.
14170146 Common Terminal,Single Cord End Terminal,Conductor Cross Section 10mm^2,50A,Insertion Depth 18mm,Ivory
Each cable (25030463) is equipped with three terminals of this type, which are used to connect the input terminal of the power distribution box.
14170016 Naked Crimping Terminal,OT,10mm^2,M6,Tin Plating,Naked Ring Terminal
Each cable (25030463) is equipped with three terminals of this type, which are used to connect the AC power distribution frame.
14170098 Common Terminal,Single Cord End Terminal,Conductor Cross Section 2.5mm^2,12.5A,Insertion Depth 8mm,Blue
Each cable (04043396) is equipped with three terminals of this type, which are used to connect the output terminal of the power distribution box.
Configuration notes of external cables and terminals of the NE40E-X3 DC chassis
Length in the Site Survey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Equal to or shorter than 15 m
25030430 Wire,450/750V,227 IEC 02(RV),16mm^2,Blue,85A
Each DC chassis is equipped with two cables of this type. The cable length is determined by the site survey result.
25030428 Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A
Each DC chassis is equipped with two cables of this type. The cable length is determined by the site survey result.
14170116 Naked Crimping Connector,JG2,16mm^2,M6,95A,Tin Plated,for OEM
Each cable is equipped with one terminal of this type, which is used to connect to the PEM.
14170024 Naked Crimping Terminal,OT,16mm^2,M8,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.
Longer than 15 m and shorter than 35 m
25030101 Wire,450/750V,227 IEC 02(RV),25mm^2,Blue,110A
Each DC chassis is equipped with two cables of this type. The cable length is determined by the site survey result.
Length in the Site Survey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
25030432 Wire,450/750V,227 IEC 02(RV),25mm^2,Black,110A
Each DC chassis is equipped with two cables of this type. The cable length is determined by the site survey result.
14170119 Naked Crimping Connector,JG2,25mm^2,M6,150A,Tin Plating,For OEM
Each cable is equipped with one terminal of this type, which is used to connect to the PEM.
14170060 Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.
Longer than 35 m A power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables of the NE40E-X3 AC chassis
BOM Number Description Configuration Notes
04000104 External Suite, Power Cords All Over The World, Class I Equipment With Connector C13,External Cable Set
Different cables are used in different countries. Each AC chassis is equipped with 2 pcs.
Rules for selecting the AC power cable for the NE40E-X3 are as follows:
1. AC power cables are selected according to local cable standards in the country
where the device is deployed.
2. The required length of the power cables is determined based on the length in the
site survey.
3. The following formulas are used to calculate the number of required power
cables:
Number of power cables of each type = 2 pcs x Number of devices
In the 100V/110V/120V AC power supply system, input of double live wires is
required. In this case, the input voltage ranges from 176 VAC to 275 VAC, and any two
phases can be input to the AC power module. In the external cable suite (04000104), the
C13-end of the three-core power cable has three terminals marked L, N, and PE. L
stands for live wire 1; N stands for live wire 1; PE stands for the ground wire. The other
end of the three-core power cable must be cut off for cable making. The terminal is
specified in the site survey.
In the 100V/110V/120V AC power supply system, if input of double live wires cannot be
provided, the NE40E-X3 AC chassis is not recommended.
Configuration notes of external cables and terminals of the NE40E-X8 DC chassis
Length in the Site Survey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Equal to or shorter than 15 m
25030430 Wire,450/750V,227 IEC 02(RV),16mm^2,Blue,85A
Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result.
25030428 Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A
Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result.
14170024 Naked Crimping Terminal,OT,16mm^2,M8,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.
14170116 Naked Crimping Connector,JG2,16mm^2,M6,95A,Tin Plated,for OEM
Each cable is equipped with one terminal of this type, which is used to connect to the PEM.
Longer than 15 m and shorter than 25 m
25030101 Wire,450/750V,227 IEC 02(RV),25mm^2,Blue,110A
Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result.
25030432 Wire,450/750V,227 IEC 02(RV),25mm^2,Black,110A
Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result.
14170060 Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.
14170119 Naked Crimping Connector,JG2,25mm^2,M6,150A,Tin Plating,For OEM
Each cable is equipped with one terminal of this type, which is used to connect to the PEM.
Longer than 25 m and shorter than 35 m
25030199 Wire,450/750V,227 IEC 02(RV),35mm^2,Blue,110A
Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result.
25030420 Wire,450/750V,227 IEC 02(RV),35mm^2,Black,110A
Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result.
14170159 Naked Crimping Connector,JG2,34.3mm^2,M6(1/4"),134A,Tin Plated,2AWG,Hole Center Distance 15.875mm(5/8"),Short Tube,for North American
Each cable is equipped with one terminal of this type, which is used to connect to the PEM.
14170063 Naked Crimping Terminal,OT,35mm^2,M8,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.
Longer than 35 m A power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables and terminals of the NE40E-X8 in AC
power supply mode
Length in the Site Survey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
The distance between the NE40E-X8 chassis and the AC-DC converter is equal to or shorter than 3 m.
25030430 Wire,450/750V,227 IEC 02(RV),16mm^2,Blue,85A
Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result.
25030428 Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A
Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result.
14170116 Naked Crimping Terminal,JG2,16mm^2,M6,95A,Tin Plated,for OEM
Each cable is equipped with two terminals of this type, which are used to connect the PEM and AC-DC converter.
04080076 Monitor and Alarm Cable,3m,D9M,CC4P0.48B(S),D9M
Each NE40E-X8 that adopts the AC power supply mode is equipped with one monitor and alarm cable, which is used to connect the AC-DC converter and the NE40E-X8 DC chassis.
The distance between the NE40E-X8 chassis and the AC-DC converter is longer than 3 m.
(1) It is recommended to deploy the AC-DC converter near the DC chassis.
(2) If it is difficult to deploy the AC-DC converter near the DC chassis, see the deployment of
the AC power cable in the DC power supply system. In this case, the DC chassis cannot
manage the AC-DC converter.
The distance between the AC-DC converter and the AC power distribution frame is equal to or shorter than 50 m.
25030461 Power Cable,300/500V,227IEC10(BVV),6mm^2,Black Jacket(Cores:Blue,Brown),43A,2 Equivalent Cores
Each AC chassis is equipped with four cables of this type.
14170023 Naked Crimping Terminal,OT,6mm^2,M6,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow
Each AC power cable is equipped with two terminals of this type on the two cores, which are used to connect to the binding post of the AC-DC converter.
14170013 Naked Crimping Terminal,OT,6mm^2,M8,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow
Each AC power cable is equipped with two terminals of this type on the two cores, which are used to connect to the binding post of the AC power distribution frame.
The distance between the AC-DC converter and the AC power distribution frame is longer than 50 m.
An AC power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables and terminals of the NE40E-X16 DC
chassis
Length in the Site Survey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Equal to or shorter than 15 m
25030430 Wire,450/750V,227 IEC 02(RV),16mm^2,Blue,85A
Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result.
25030428 Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A
Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result.
14170024 Naked Crimping Terminal,OT,16mm^2,M8,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.
14170116 Naked Crimping Terminal,JG2,16mm^2,M6,95A,Tin Plated,for OEM
Each cable is equipped with one terminal of this type, which is used to connect to the PEM.
Longer than 15 m and shorter than 35 m
25030101 Wire,450/750V,227 IEC 02(RV),25mm^2,Blue,110A
Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result.
25030432 Wire,450/750V,227 IEC 02(RV),25mm^2,Black,110A
Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result.
14170060 Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.
14170119 Naked Crimping Connector,JG2,25mm^2,M6,150A,Tin Plating,For OEM
Each cable is equipped with one terminal of this type, which is used to connect to the PEM.
Longer than 25 m and shorter than 35 m
25030199 Wire,450/750V,227 IEC 02(RV),35mm^2,Blue,135A
Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result.
25030420 Wire,450/750V,227 IEC 02(RV),35mm^2,Black,135A
Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result.
14170159 Naked Crimping Connector,JG2,34.3mm^2,M6(1/4"),134A,Tin Plated,2AWG,Hole Center Distance 15.875mm(5/8"),Short Tube,for North American
Each cable is equipped with one terminal of this type, which is used to connect to the PEM.
14170063 Naked Crimping Terminal,OT,35mm^2,M8,Tin Plating,Naked Ring Terminal
Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.
Longer than 35 m A power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables and terminals of the NE40E-X16 in AC
power supply mode
Length in the Site Survey Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
The distance between the 25030430 Wire,450/750V,227 IEC Each DC chassis is equipped with
Length in the Site Survey Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
NE40E-X16 chassis and the AC-DC converter is equal to or shorter than 3 m.
02(RV),16mm^2,Blue,85A eight cables of this type. The cable length is determined by the site survey result.
25030428 Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A
Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result.
14170116 Naked Crimping Terminal,JG2,16mm^2,M6,95A,Tin Plated,for OEM
Each cable is equipped with two terminals of this type, which are used to connect the PEM and AC-DC converter.
04080076 Monitor and Alarm Cable,3m,D9M,CC4P0.48B(S),D9M
Each NE40E-X16 that adopts the AC power supply mode is equipped with two monitor and alarm cables, which are used to connect the AC-DC converter and the NE40E-X16 DC chassis.
The distance between the NE40E-X16 chassis and the AC-DC converter is longer than 3 m.
(1) It is recommended to deploy the AC-DC converter near the DC chassis.
(2) If it is difficult to deploy the AC-DC converter near the DC chassis, see the deployment
of the AC power cable in the DC power supply system. In this case, the DC chassis
cannot manage the AC-DC converter.
The distance between the AC-DC converter and the AC power distribution frame is equal to or shorter than 50 m.
25030461 Power Cable,300/500V,227IEC10(BVV),6mm^2,Black Jacket(Cores:Blue,Brown),43A,2 Equivalent Cores
Each AC chassis is configured with four cables of this type.
14170023 Naked Crimping Terminal,OT,6mm^2,M6,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow
Each AC power cable is equipped with two terminals of this type on the two cores, which are used to connect to the binding post of the AC-DC converter.
14170013 Naked Crimping Terminal,OT,6mm^2,M8,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow
Each AC power cable is equipped with two terminals of this type on the two cores, which are used to connect to the binding post of the AC power distribution frame.
The distance between the AC-DC converter and the AC power distribution frame is longer than 50 m.
An AC power distribution frame or the first power cabinet of a row should be placed near the device.
2) Configuration Notes of Ground Cables
Configuration notes of the ground cable and terminals used on the NE40E-X3
BOM Number Description Configuration Notes
25030431 Wire,450/750V,60227 IEC 02(RV)25mm^2,yellow green,110A
Each device is equipped with one such power cable. The length of the power cable is based on the site survey result. If the device is grounded through a cabinet, the
BOM Number Description Configuration Notes
length of the ground cable is a1 shown in 错误!未找到引
用源。; if the device is grounded through a chassis, the
length of the ground cable is a3 shown in 错误!未找到引
用源。.
14170119 Naked Crimping Connector,JG2,25mm^2,M6,150A,Tin Plating,For OEM
One such terminal is used to connect to the ground terminal on the chassis.
14170060 Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal
When a device is grounded through a chassis, one such terminal is used to connect to the ground bar in the equipment room.
If a device is grounded through a cabinet, one such terminal is used to connect to the ground point on the cabinet.
Configuration notes of the ground cable and terminals used on the
NE40E-X8/NE40E-X16
BOM Number Description Configuration Notes
25030431 Wire,450/750V,60227 IEC 02(RV)25mm^2,yellow green,110A
Each device is equipped with one such power cable. The length of the power cable is based on the site survey result. If the device is grounded through a cabinet, the length of the ground cable is
a1 shown in 错误!未找到引用源。; if the device is
grounded through a chassis, the length of the
ground cable is a3 shown in 错误!未找到引用源。.
14170119 Naked Crimping Connector,JG2,25mm^2,M6,150A,Tin Plating,For OEM
One such terminal is used to connect to the ground terminal on the chassis.
14170060 Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal
When a device is grounded through a chassis, one such terminal is used to connect to the ground bar in the equipment room.
If a device is grounded through a cabinet, one such terminal is used to connect to the ground point on the cabinet.
Configuration Notes of Ground Cable of the EPS200-4850A
The external AC-DC converter EPS200-4850A of the NE40E-X8/NE40E-X16 needs to be
separately grounded. Therefore, the 25 mm^2 ground cable is needed. The below lists the
configuration notes of the ground cable and terminals used on the EPS200-4850A.
Configuration notes of the ground cable and terminals used on the
EPS200-4850A
BOM Number Description Configuration Notes
25030431 Wire,450/750V,60227 IEC 02(RV)25mm^2,yellow green,110A
Each device is equipped with one such power cable. The length of the power cable is based on the site survey result. If the device is grounded through a cabinet, the length of the ground cable is a1 shown in
错误!未找到引用源。; if the device is grounded
through a chassis, the length of the ground cable is
a3 shown in 错误!未找到引用源。.
14170119 Naked Crimping Connector,JG2,25mm^2,M6,150A,Tin Plating,For OEM
One such terminal is used to connect to the ground terminal on the chassis.
14170060 Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal
When a device is grounded through a chassis, one such terminal is used to connect to the ground bar in the equipment room.
If a device is grounded through a cabinet, one such terminal is used to connect to the ground point on the cabinet.
3) Configuration Notes of Clock Cables
List of clock cables that can be used in NE40E&80E V600R005C00
No. BOM Number Description Length Cable Type Configuration Notes
1 04022629 Trunk Cable,20.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,HONET,DL2526
20 m Cable with one SMB connector which is used to connect to the MPU/SRU. The connector on the other end of the cable must be provided by the customer.
These cables are not supported on the CR52MPUD.
Each CR52MPUA0/CR52SRUA0/CR52MPUB0/CR52SRUA1 can have 0 to 4 pcs.
Each CR52MPUB2/CR52SRUA3/CR56MPUB4/CR57SRU40A4 can have 0 to 2 pcs.
2 04060205 Trunk Cable,30.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,Wireless Intelligent Network
30 m
3 04023971 Trunk Cable,40.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,C&C08B,DL3133
40 m
4 04023972 Trunk Cable,50.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,C&C08B,DL3134
50 m
5 04060171 Trunk Cable,155M Self-Loop,5m,75ohm,4.0mm,SMB75SF-IV,SYV75-2/0.34(S),SMB75SF-IV,OptiX
5 m Cable with two SMB connectors
6 04040497 Trunk Cable,3m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-II,Expert 2.0
3 m Cable with RJ48 connectors
Each CR52MPUD/CR52MPUB2/CR52SRUA3/CR56MPUB4/CR57SRU40A4 can have 0 to 2 pcs.
These cables are not supported on the CR52MPUA0/CR52SRUA0/CR52MPUB0/CR52SRUA1.
7 04040261 Trunk Cable,15m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-II
15 m
8 04040496 Trunk Cable,30m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-II,Expert 2.0
30 m
9 04040494 Trunk Cable,60.00m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),
60 m
No. BOM Number Description Length Cable Type Configuration Notes
MP8-II,Expert 2.0
10 04040493 Trunk Cable,80m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-II,Expert 2.0
80 m
11 14080082 Network Interface Connector,8Bit 8Pin,Crystal Plug,Matching 25050014
2 pcs Cable with RJ45 connectors
These cables are optional when the clock interfaces on the CR52MPUD/CR52MPUB2/CR52SRUA3/CR56MPUB4/CR57SRU40A4 support 1PPS+TOD or DCLS.
12 25050014 Twisted-Pair Cable,100ohm,Category 5e UTP,0.51mm,24AWG,8Cores,PANTONE 430U,Use with Plug:14080082
Based on the site survey result
Balanced cable
4) Configuration Notes of E1/T1 Interface Cables
Configurations of the conversion box and cables for the CR5M1CFE1
BOM Number Description Configuration Notes
02351606 NetEngine80E,CR5Z1DCRF,24*E1/T1 DB100 to RJ48 Port Conversion Box
The conversion box of this type corresponds to one CR5M1CFE1 LPU. The LPU and the conversion box are connected through the 04070064 cable. The conversion box is separately packaged.
02351607 NetEngine80E,CR5Z1DCRM,48*E1/T1 DB100 to RJ48 Port Conversion Box
The conversion box of this type corresponds to two CR5M1CFE1 LPUs. The LPU and the conversion box are connected through two sets of 04070064 cables. The conversion box is separately packaged.
02351608 NetEngine80E,CR5Z1DCSF,24*E1 DB100 to SMB Port Conversion Box
The conversion box of this type corresponds to one CR5M1CFE1 LPU. The LPU and the conversion box are connected through the 04070064 cable. The conversion box is separately packaged.
04070064 Signal cable,24E1 Transit Cable,4m,D100M-I,3*CC16P0.4P430U(S)-I,D100M-I
It is used to connect the E1 conversion box and E1 LPU. Each LPU is equipped with one cable of this type.
If coaxial cables with SMB connectors are used, the conversion box
02351608 must be selected. If twisted pair cables with RJ48 connectors are used,
the conversion box 02351606 or 02351607 must be selected. When the interface
on the CFE1 board needs to be connected to the E1 interface on another device,
you need to take the matching between cable impedances into consideration
when selecting a cable.
1. The peer interface (RJ48) uses the 120-ohm balanced cable.
When the remote interface uses the balanced 120-ohm twisted cable and
RJ48 connector, select the E1 trunk cable from Table 8-26 based on the site
survey length. The listed cables are with RJ48 connectors at both ends.
E1 trunk cable list (RJ48 interface)
No. BOM Number Description Quantity Unit
1 04040497 Trunk Cable,3m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-II,Expert 2.0
One for each E1 interface
pcs
2 04040261 Trunk Cable,15m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-II
One for each E1 interface
pcs
3 04040496 Trunk Cable,30m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-II,Expert 2.0
One for each E1 interface
pcs
4 04040494 Trunk Cable,60.00m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-II,Expert 2.0
One for each E1 interface
pcs
5 04040493 Trunk Cable,80m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-II,Expert 2.0
One for each E1 interface
pcs
2. The peer interface (SMB) uses the 75-ohm unbalanced cable.
When the remote interface uses the SMB connector, the conversion box 02351608 should
be selected for the CFE1 LPU, providing 24 SMB interfaces. Select corresponding cables
from Table 8-28 based on the site survey length.
In addition, the SMB trunk cable has one connector on one end, used to connect to the
conversion box. The other end of the cable connected to the customer device does not
have any connector, and the customers must prepare the connector themselves. In this
application, the maximum transmission distance is shorter than 200 m.
List of E1 trunk cables with SMB connectors
No. BOM Number Description Quantity Unit
1 04026814 Single Cable,120ohm,75ohm Converter Box(With SMB Socket 14040127),PCB03022834+Box Body 21210634)
1 pcs
2 04022627 Trunk Cable,10.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,HONET,W2524
2 pcs
3 04022629 Trunk Cable,20.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,HONET,DL2526
2 pcs
4 04060205 Trunk Cable,30.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,Wireless Intelligent Network
2 pcs
5 04023971 Trunk Cable,40.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,C&C08B,DL3133
2 pcs
6 04023972 Trunk Cable,50.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,C&C08B,DL3134
2 pcs
7 04043079 Trunk Cable,65.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25
2 pcs
No. BOM Number Description Quantity Unit
8 04042130 Trunk Cable,70m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25
2 pcs
9 04042131 Trunk Cable,80m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25
2 pcs
10 04042132 Trunk Cable,90m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25
2 pcs
11 04043080 Trunk Cable,100.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25
2 pcs
12 04060171 Trunk Cable,155M Self-Loop,5m,75ohm,4.0mm,SMB75SF-IV,SYV75-2/0.34(S),SMB75SF-IV,OptiX
2 pcs
5) Configuration Notes of the E3/T3 Interface Cable
List of E3 trunk cables with SMB connectors
No. BOM Number Description Quantity Unit
1 04060171 Trunk Cable,155M Self-Loop,5m,75ohm,4.0mm,SMB75SF-IV,SYV75-2/0.34(S),SMB75SF-IV,OptiX
2 pcs
2 04044335 Trunk Cable,155M/Clock/Lightning,10m,75ohm,3.9mm,SMB75SF-IV,SYV75-2/0.34(S)
2 pcs
3 04044336 Trunk Cable,155M/Clock/Lightning,20m,75ohm,3.9mm,SMB75SF-IV,SYV75-2/0.34(S)
2 pcs
4 04044337 Trunk Cable,155M/Clock/Lightning,30m,75ohm,3.9mm,SMB75SF-IV,SYV75-2/0.34(S)
2 pcs
8 External Optical Fiber Suites
List of commonly used optical fibers in the optical fiber suite (04100069)
No. BOM Number Description Quantity Unit
1 14130296 Patch Cord,LC/PC-LC/PC,Multimode,A1b,2mm,5m The type and the number of fibers depend on the site survey result.
pcs
2 14130222 Patch Cord,LC/PC-LC/PC,Multimode,2mm,10m pcs
3 14130295 Patch Cord,LC/PC-LC/PC,Multimode,2mm,20m pcs
4 14130195 Patch Cord,LC/PC-LC/PC,Singlemode,2mm,5m pcs
5 14130199 Patch Cord,LC/PC-LC/PC,Singlemode,2mm,10m pcs
6 14130251 Patch Cord,LC/PC-LC/PC,Singlemode,2mm,20m pcs
7 14130248 Adapter,LC/PC-LC/PC,2,Blue,Shell:Plastic,Sleeve:Zirconia,Square
pcs
8 14130197 Patch Cord,FC/PC,LC/PC,Singlemode,2mm,10m pcs
9 14130221 Patch Cord,FC/PC,LC/PC,Multimode,2mm,10m pcs
10 14130196 Patch Cord,LC/PC-SC/PC,Singlemode,2mm,10m pcs
11 14130223 Patch Cord,LC/PC-SC/PC,Multimode,2mm,10m pcs
12 14130375 Patch Card,MPO-MPO,Multimode,0.3m,8 Cores Ribbon Fiber
pcs
13 14130335 Optic Fiber Connector,LC/PC,LC/PC,Multi-mode,2mm,1m
pcs
9 Accessories
List and configuration description of accessories of the NE40E-X16
No. Code Description Configuration Notes
0 21100144 Nonmetal Parts,DKBA0.480.0457-GT-300I- Wire Clip-300*3.6mm-Strength 18.2kg
Each NE40E-X16 is configured with 200 pcs.
It is not required on the NE80E.
1 21100015 Nonmetal Parts,DKBA0.480.0457-GT 150I,Wire Strip,150*3.6mm,Strength 18.2kg
It is mandatory. Each NE80E/NE40E-X16 is configured with 100 pcs.
2 21100041 Nonmetal Parts,DKBA0.480.0457-GT 100M,Wire Strip,100*2.5mm,Strength 8.1kg
It is mandatory. Each NE80E/NE40E-X16 is configured with 100 pcs.
3 28010026 Insulation Material,Fireproof PVC Corrugated Tube,D2 It is optional and is provided for the NE40E/80E-16 to be delivered only outside China. It is selected based on the site survey result. By default, a 30 m tube is provided.
4 14080082 Network Interface Connector,8Bit 8Pin,Crystal Plug,Matching 25050014
It is provided based on the site survey result. By default, it is not provided.
5 25050014 Twisted-Pair Cable,100ohm,Category 5e UTP,0.51mm,24AWG,8Cores,PANTONE 430U,Used with Plug:14080082
It is provided based on the site survey result. By default, it is not provided.
6 29041060 Engineering/Blank label,Engineering label,Signal Cable label,30 Groups,10 Array,3 Row,Height 22.0,Width 84.0,Matte White,1Pcs/Group
It is mandatory. Each NE80E/NE40E-X16 is configured with 6 pcs.
7 29042491 DKBA4.150.0999MX,Cabinet LOGO,Router,90mm*30mm,Plastic
It is mandatory when a cabinet is delivered. Each NE80E/NE40E-X16 is configured with 2 pcs.
No. Code Description Configuration Notes
8 02234474 NetEngine5000E,Engineering Required Delivery Accessory Per Integrated Chassis
It is mandatory. Each NE80E/NE40E-X16 is configured with 1 pcs.
9 21500093 Q/DKBA4.127.0355MX,Side Hang FMTs,NGN Cabinet It is mandatory when a cabinet is delivered. Each NE80E/NE40E-X16 is configured with 4 pcs.
10 26010552 Cross Recessed Pan Head Thread forming Screws,M5*10,Zinc Electroplating, iridescent yellow,GB6560-86
It is mandatory when a cabinet is delivered. Each NE80E/NE40E-X16 is configured with 8 pcs. The NE80E with the AC power supply are configured with 16 pcs. The screws are used to fix the slide rails of the AC power distribution cabinet. Each slide rail is configured with 4 pcs. There are four slide rails; therefore, the NE80E needs to be configured with 16 pcs.
11 31185644 HUAWEI NetEngien40E Universal Service Router Product Documentation-(V600R005C00_01)
It is quoted separately. Each NE40E, NE40E-X3, NE40E-X8, or NE40-X16 to be delivered outside China is configured with 1 pcs. This CD-ROM applies to only a router running V600R005C00; for a router running another version, an appropriate CD-ROM is required.
12 31185645 HUAWEI NetEngien40E Universal Service Router Product Documentation-(V600R005C00_01)
It is quoted separately. Each NE80E is configured with 1 pcs. This CD-ROM applies to only a router running V600R005C00; for a router running another version, an appropriate CD-ROM is required.
13 31185648 HUAWEI NetEngien80E Core Router Product Documentation-(V600R005C00_01)
It is quoted separately. Each NE80E to be delivered in China is configured with 1 pcs. This CD-ROM applies to only a router running V600R005C00; for a router running another version, an appropriate CD-ROM is required.
14 31185649 HUAWEI NetEngien80E Core Router Product Documentation-(V600R005C00_01)
It is quoted separately. Each NE80E to be delivered outside China is configured with 1 pcs. This CD-ROM applies to only a router running V600R005C00; for a router running another version, an appropriate CD-ROM is required.
15 02400376 Power Distribution Cabinet,220V,50/60HZ,72000mA,None,EPS200-4850A
It is quoted separately. It is mandatory when an NE40E-X16 with the AC power supply is delivered. Each NE40E-X16 is configured with 2 pcs.
16 02130872 Power module--33degC-65degC-90VAC-290VAC-(-53.5)VDC
It is quoted separately. It is mandatory when an NE80E/NE40E-X16 with the AC
No. Code Description Configuration Notes
/54.2A-AC/DC rectifier power supply is delivered. Each NE80E/NE40E-X16 is configured with 8 pcs.
17 21240150 DKBA8.201.1797,Standard Guide Rail,N68E Cabinet It is mandatory when an NE40E-X16 with two AC power supply cabinets is to be delivered. Each NE40E-X16 is configured with 4 pcs, with each AC power supply cabinet configured with with 2 pcs.
18 02120415 NetEngine5000E,CR5E3TSR,AC Distribution Frame for Cabinet,2 or 6 Input,6(2*3) Output,6 Group of 2 Poles 20A Air Switch
It is quoted separately. It is mandatory when an NE80E with the AC power supply is delivered. Each NE80E is configured with 1 pcs.
19 05116036
05116037
NetEngine40E&80E-4/8/16, NetEngine40E&80E-4/8/16_C V600R005C00,Physical Software Package,DVD China
NetEngine40E&80E-4/8/16, NetEngine40E&80E-4/8/16_O V600R005C00,Physical Software Package,DVD Oversea
It is provided for the NE40E-8, NE40E-4, or NE80E to be delivered outside China. Each NE40E-8, NE40E-4, or NE80E is configured with 1 pcs. By default, it is not provided.
20 05116038
05116039
NetEngine40E-X8/X16,NetEngine40E-X8/X16_C V600R005C00,Physical Software Package, DVD China
NetEngine40E-X8/X16,NetEngine40E-X8/X16_O V600R005C00,Physical Software Package, DVD Oversea
It is mandatory. Each NE80E is configured with 1 pcs.
21 28040011 Heat shrink tube/D11/Radial Shrinkage Ratio>50%/Black
The insulated heat shrink tube is selected according to 0.
22 28040009 Heat shrink tube,D14,Radial Shrinkage Ratio>50%,Black
The insulated heat shrink tube is selected according to 0.
23 28040013 Heat Shrink Tube/D18/Radial Shrink Rate>50%/Black The insulated heat shrink tube is selected according to 0.
25 02120641 Power Distribution Box,NE40E,DPD300-4-12,Dual-two Inputs .Dual-six outputs ,High Power DC Distribution Box,per output 80A
It is configured based on the site survey result. When customers cannot provide 12 power channels for the NE40E/80E-X16/-16, a power distribution is required. Customers need to purchase power cables for the power distribution box. Each Power distribution box can support one NE40E/80E-X16/-16.
26 21240446
21240447
DKBA61533919,X8 Mount_19inch,NE40E
DKBA61532828,X8 Mount_23inch,NE40E
It is mandatory for the NE40E-X8 (02354085) and NE40E-X16(02354084) to be delivered to the North America market. An NE40E-X8 is configured with 1 pcs and an NE40E-X16 is configured with 2 pcs.
List and configuration description of NE40E-X3/NE40E-X8 accessories
No. Code Description Configuration Notes
0 21100144 Nonmetal Parts,DKBA0.480.0457-GT-300I- Wire Clip-300*3.6mm-Strength 18.2kg
Each NE40E-X8 is configured with 100 pcs. It is not required by other devices.
1 21100015 Nonmetal Parts,DKBA0.480.0457-GT 150I,Wire Strip,150*3.6mm,Strength 18.2kg
It is mandatory. Each NE40E-X8 is configured with 100 pcs.
2 21100041 Nonmetal Parts,DKBA0.480.0457-GT 100M,Wire Strip,100*2.5mm,Strength 8.1kg
It is mandatory. Each NE40E-X8 is configured with 100 pcs.
3 14080082 Network Interface Connector,8Bit 8Pin,Crystal Plug,Matching 25050014
It is provided based on the site survey result. By default, it is not provided.
4 25050014 Twisted-Pair Cable,100ohm,Category 5e UTP,0.51mm,24AWG,8Cores,PANTONE 430U,Use with Plug:14080082
It is provided based on the site survey result. By default, it is not provided.
5 28010026 Insulation Material,Fireproof PVC Corrugated Tube,D25
It is optional and is provided for the NE40E-X8 to be delivered only outside China. It is selected based on the site survey result. By default, a 30 m tube is provided.
6 29041060 Engineering/Blank label,Engineering label,Signal Cable label,30 Groups,10 Array,3 Row,Height 22.0,Width 84.0,Matte White,1Pcs/Group
It is mandatory. Each NE40E-X8 is configured with 4 pcs.
7 29042491 DKBA4.150.0999MX,Cabinet LOGO,Router,90mm*30mm,Plastic
It is mandatory when a cabinet is delivered. Each NE40E-X8 is configured with 2 pcs.
8 31185644 HUAWEI NetEngien40E Universal Service Router Product Documentation-(V600R005C00_01)
It is quoted separately. Each NE40E, NE40E-X3, NE40E-X8, or NE40-X16 to be delivered inside China is provided with 1 pcs. This CD-ROM applies to only a router running V600R005C00; for a router running another version, an appropriate CD-ROM is required.
9 31185645 HUAWEI NetEngien40E Universal Service Router Product Documentation-(V600R005C00_01)
It is quoted separately. Each NE40E, NE40E-X3, NE40E-X8, or NE40-X16 to be delivered outside China is provided with 1 pcs. This CD-ROM applies to only a router running V600R005C00; for a router running another version, an appropriate CD-ROM is required.
10 02234474 NetEngine5000E,Engineering Required Delivery Accessory Per Integrated Chassis
It is mandatory. Each NE40E-X8 is configured with 1 pcs.
11 21500093 Q/DKBA4.127.0355MX,Side Hang FMTs,NGN Cabinet
It is mandatory when a cabinet is delivered. Each NE40E-X8 is configured with 2 pcs.
12 26010552 Cross Recessed Pan Head Thread forming Screws,M5*10,Zinc Electroplating, iridescent yellow,GB6560-86
It is mandatory when a cabinet is delivered. Each NE40E-X8 with the DC power supply is configured with 4 pcs.
Each NE40E-X8 with the AC power supply is configured with 8 pcs.
13 02400376 Power Distribution Cabinet,220V,50/60HZ,72000mA,None,EPS200-485
It is quoted separately. It is mandatory on an NE40E-X8 with
No. Code Description Configuration Notes
0A the AC power supply. Each NE40E-X8 is configured with 1 pcs.
14 02130872 Power module--33degC-65degC-90VAC-290VAC-(-53.5)VDC/54.2A-AC/DC rectifier
It is quoted separately. It is mandatory on an NE40E-X8 with the AC power supply. Each NE40E-X8 is configured with 4 pcs. It is not provided for other cabinets.
15 21240150 DKBA8.201.1797,Standard Guide Rail,N68E Cabinet It is mandatory for an NE40E-X8 with the AC power supply. Each NE40E-X8 is configured with 2 pcs for installing the AC-input cabinet.
16 05116036
05116037
NetEngine40E&80E-4/8/16, NetEngine40E&80E-4/8/16_C V600R005C00,Physical Software Package,DVD China
NetEngine40E&80E-4/8/16, NetEngine40E&80E-4/8/16_O V600R005C00,Physical Software Package,DVD Oversea
It is applicable to the NE40E-8/-4 and NE80E and sold based on versions. By default, it is not delivered with the router.
05116038
05116039
NetEngine40E-X8/X16,NetEngine40E-X8/X16_C V600R005C00,Physical Software Package, DVD China
NetEngine40E-X8/X16,NetEngine40E-X8/X16_O V600R005C00,Physical Software Package, DVD Oversea
It is applicable to the NE40E-X8/-X16 and sold based on versions. By default, it is not delivered with the router.
05116040
05116041
NetEngine40E-X3,NetEngine40E-X3_C V600R005C00,Physical Software Package,DVD China
NetEngine40E-X3,NetEngine40E-X3_O V600R005C00,Physical Software Package,DVD Oversea
It is applicable to the NE40-X3 and sold based on versions. By default, it is not delivered with the router.
19 21500182 DKBA4.150.0747MX,Mount Angle,NE20-4(3U) Chassis of NGN
It is mandatory. Each 20 U NE40E-8 (02351014) is configured with 1 pcs.
20 21500200 DKBA4.150.0546MX,Mount Angle Component,NE40E
It is mandatory. Each 22 U NE40E-8 (02350762) is configured with 1 pcs.
21 21240160 DKBA4.150.0923MX,Mount,NE40E-4 It is mandatory. Each NE40E-4 is configured with 1 pcs.
22 28040011 Heat shrink tube/D11/Radial Shrinkage Ratio>50%/Black
The insulated heat shrink tube is selected according to 0.
23 28040009 Heat shrink tube,D14,Radial Shrinkage Ratio>50%,Black
The insulated heat shrink tube is selected according to 0.
24 28040013 Heat Shrink Tube/D18/Radial Shrink Rate>50%/Black
The insulated heat shrink tube is selected according to 0.
25 02120641 Power Distribution Box,NE40E,DPD300-4-12,Dual-two Inputs .Dual-six outputs ,High Power DC Distribution Box,per output 80A
It is configured based on the site survey result. When customers cannot provide six power channels for the NE40E/80E-X8/-8, a power distribution is required. Customers need to purchase power cables for the power distribution box. Each power distribution box can support a maximum of two
No. Code Description Configuration Notes
NE40E/80E-X8/-8s.
26 21240442
21240443
DKBA61532830,X3(DC) Mount_19inch,NE40E
DKBA61532826,X3(DC) Mount_23inch,NE40E
It is designed exclusively and mandatory for the NE40X3-DC chassis (0235****) to be delivered to the North America market.
27 21240444
21240445
DKBA61532831,X3(AC) Mount_19inch,NE40E
DKBA61532827,X3(AC)Mount_23inch,NE40E
It is designed exclusively and mandatory for the NE40X3-DC chassis (02354559) to be delivered to the North America market.
28 21240446
21240447
DKBA61533919,X8 Mount_19inch,NE40E
DKBA61532828,X8 Mount_23inch,NE40E
It is designed exclusively and mandatory for the NE40E-X8 (02354085) and NE40E-X16(02354084) to be delivered to the North America market. An NE40E-X8 is configured with 1 pcs and an NE40E-X16 is configured with 2 pcs.
Insulated heat shrink tubes on different chassis/core diameters of power cables
Cable Diameter
Code of an Insulated
Heat Shrink Tube
Length of an Insulated Heat
Shrink Tube (cm)
NE40E-X16 NE40E-X8 NE40E-X3
16mm2 28040011 150 100 50
25mm2 28040009 150 100 50
35mm2 28040013 150 100