Overview

Huawei PowerCube, the new generation hybrid power solutions for off-grid or unstable grid applications. It offers

efficient and stable power for wireless sites, school, enterprise and governments etc.

With the newest energy controlling and transferring technology, it makes full use of energy sources such as solar,

diesel and grid. Compared with traditional Dual-D.G. solution, PowerCube can greatly decrease TCO and bring

sustainable development for customers.

The core concept of PowerCube is “Saving, Single, Smart”.

Saving: fuel 40%-60%, footprint 30%-70%, maintenance up to 90%

Single: single platform, modular design, smooth expansion & evolution

Smart: intelligent NetEco system achieves highly efficient operation & maintenance management

PowerCube product portfolio

PowerCube 1000

High power consumption: co-site,

enterprise, school, institution of public

character, village

Medium power consumption:

mobile site, small village

PowerCube 500

Low power consumption: video surveillance, small cell, wifi

Diesel hybrid

Grid hybrid

Solar hybrid

0KW

1KW

3KW

20KW

Unstable GridGood Grid Off Grid

01

PowerCube 500

PowerCube 500 is a pure solar power

solution for small load application,

especially it’s suit for LED streetlamp,

Video Surveillance and Wireless LAN

system. Due to its characters of long

backup time, sturdy and stable, it can

be widely used in the off-grid or poor

grid areas such as highway, oil pipeline,

forest and other unattended areas.

No. ModelRated Load

(W)

Output

VoltagesLoad height

Peak solar

radiationBackup time

Solar

moduleBattery

1 S111M1 1~25

DC12V DC48V

POE(optional)

6m >3.5h 72h 280Wp 200Ah

2 S111M2 25~40 6m >3.5h 72h 420Wp 300Ah

3 S111M3 40~55 6m >3.5h 72h 560Wp 400Ah

4 S111M4 55~70 6m >4.5h 72h 560Wp 500Ah

5 S111M 1~50

DC24V

DC48V

POE(optional)

10m 4.8KWh 72h 380Wp 200Ah

No. Model Lamp power Lamp heightAverage

luminance

Peak solar

radiationBackup time

6 S111T1 80W 8m >10lux > 4h/day 3 day

7 S111T2 60W*2 8m >10lux > 5h/day 3 day

8 S111T3 80W+30W 8m, 4m >10lux > 5h/day 3 day

*Remarks: S111M1/S111M2/S111M3/S111M4 for Video Surveillance; S111M for WLAN; S111T1/S111T2/S111T3 for Street Lamp

02

PowerCube1000-D

PowerCube 1000-D is applicable in off-grid & poor grid areas. This solution solves the problems of low conversion

efficiency, high fuel consumption, heavy maintenance and component theft.

D532A D532D D502D D532A2 D532D2 D502D1 D532A4 D532D4 D502D2 D703A1 D703D2 D703P

Rated Load (W) 1250 1300 1300 1800 1900 1900 2350 2400 2400 2800 2950 2950

Load Power Range (W)

1000 ~ 1500

1000 ~ 1600

1000 ~ 1600

1500 ~ 2100

1600 ~ 2200

1600 ~ 2200

2100 ~ 2500

2200 ~ 2600

2200 ~ 2600

2500 ~ 3100

2600 ~ 3300

2600 ~ 3300

Scenario Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Indoor

Reuse D.G. N N Y N N Y N N Y Y Y Y

EPM Capacity (KW)* 10 10 / 10 10 / 10 10 / / / /

Fuel Tank Capacity (L) 800 800 / 800 800 / 800 800 / / / /

EPM MaintenanceInterval (hr)*

1000 1000 / 1000 1000 / 1000 1000 / / / /

Cooling method forICC*

Heat Exchange

Heat Exchange

Heat Exchange

Heat Exchange

Heat Exchange

Heat Exchange

Heat Exchange

Heat Exchange

Heat Exchange

Heat Exchange

Heat Exchange

/

Cooling method forESS*

DC-Air Conditioner

DirectCooling

DirectCooling

DC-Air Conditioner

DirectCooling

DirectCooling

DC-Air Conditioner

DirectCooling

DirectCooling

DC-Air Conditioner

DirectCooling

/

Dimensions(W×D×H ) (mm)

3555 x 1135 x 2110

3555 x 1135 x 2110

1755 x 1135 x 2110

3555 x 1135 x 2110

3555 x 1135 x 2110

1755 x 1135 x 2110

3555 x 1135 x 2110

3555 x 1135 x 2110

1755 x 1135 x 2110

1755 x 1135 x 2110

1755 x 1135 x 2110

/

Weight (Kg) <2597 <2547 <1662 <3245 <3195 <2310 <3494 <3444 <2559 <2872 <2822 <2400

Customer EquipmentSpace/ Heat Consumption

13U/750W 13U/750W 13U/750W 13U/750W 13U/750W 13U/750W 13U/750W 13U/750W 13U/750W 13U/750W 13U/750W /

*Remarks: EPM - Energy Plant Model; ESS - Energy Storage System; ICC - Integrated Controller & Converter.

03

PowerCube 1000-S is applicable in off-grid areas with abundant solar energy. It adopts PV modules to convert solar

power into electric power in order to save OPEX. This solution is “0” carbon emission & low maintenance required.

S302N S332D-D1 S303N S304N S563D-D3 S532N-D0 S553N-D0 S564N-D0 S564P-D0

Rated Load (W) 390 450 680 860 1200 1400 1800 2400 2500

Scenario Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Indoor

Reuse D.G. / N / / N Y Y Y Y

EPM Capacity (KW)* / 4.2 / / 12 / / / /

Solar Supply Unit Capacity (A) 50A*1 50A*1 50A*1 50A*2 50A*2 50A*1 50A*2 50A*2 50A*2

Solar Supply Unit Tracking Precision (Max)

99.8% 99.8% 99.8% 99.8% 99.8% 99.8% 99.8% 99.8% 99.8%

Solar Supply Unit Efficiency (Max)

98.5% 98.5% 98.5% 98.5% 98.5% 98.5% 98.5% 98.5% 98.5%

ESS Type* ESS - S ESS - D ESS - S ESS - S ESS - D ESS - D ESS - D ESS - D ESS - D

ESS Capacity (KWh)* 38.4 31.2 57.6 76.8 76.8 38.4 57.6 76.8 76.8

Cooling method for ICC* Heat Exchange Heat Exchange Heat Exchange Heat Exchange Heat Exchange Heat Exchange Heat Exchange Heat Exchange /

Cooling method for ESS* Natural Cooling Direct Cooling Natural Cooling Natural Cooling Direct Cooling Natural Cooling Natural Cooling Natural Cooling /

Supporter TypeScalable

SupporterScalable

SupporterScalable

SupporterScalable

SupporterScalable

SupporterScalable

SupporterScalable

SupporterScalable

SupporterScalable

Supporter

Weight Excludes PV module (Kg) <1756 <1654 <2883 <3405 <2724 <2706 <4325 <5767 <3265

Wind-resistance Level ≤50m/s ≤50m/s ≤50m/s ≤50m/s ≤50m/s ≤50m/s ≤50m/s ≤50m/s ≤50m/s

*Remarks: ICC - Integrated Controller & Converter; ESS - Energy Storage System.

PowerCube1000-S

04

PowerCube1000-G

PowerCube 1000-G is applicable in the areas with poor or unstable grid. By using intelligent energy scheduling

strategy to maximally use grid in order to reduce the EPM running time or even remove it.

G301A G301A2 G302A G501A1 G501A4 G702A G301P G501P2 G502P G501P1 G501P3 G702P1

Rated Power (W) 600 900 1500 1800 2100 2800 1250 1700 1800 2000 2300 3000

Scenario Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Indoor Indoor Indoor Indoor Indoor Indoor

Power Supply Unit Capacity (A)

50A*3 50A*2 50A*5 50A*7 50A*5 50A*7 50A*4 50A*3 50A*5 50A*7 50A*5 50A*7

Power Supply Unit Efficiency (Max)

96.8% 96.8% 96.8% 96.8% 96.8% 96.8% 96.8% 96.8% 96.8% 96.8% 96.8% 96.8%

ESS Type* ESS - F ESS - A ESS - F ESS - H ESS - A ESS - H ESS - F ESS - A ESS - F ESS - H ESS - A ESS - H

ESS Capacity (KWh)* 14.4 9.6 31.2 24 19.2 31.2 24 14.4 31.2 24 19.2 31.2

Cooling method of ICC*

Heat Exchange

Heat Exchange

Heat Exchange

Heat Exchange

Heat Exchange

Heat Exchange

/ / / / / /

Cooling method of ESS*

DC-Air Conditioner

DC-Air Conditioner

DC-Air Conditioner

DC-Air Conditioner

DC-Air Conditioner

DC-Air Conditioner

/ / / / / /

Dimensions (W×D×H) (mm)

770 x 1250 x 1825

770 x 1250 x 1825

770 x 1250 x 1825

770 x 1250 x 1825

1755 x 1135 x 2100

1755 x 1135 x 2100

/ / / / / /

Weight (Kg) <300 <300 <300 <400 <300 <400 <300 <300 <300 <300 <300 <400

Customer Equipment Space/ Heat Consumption

12U/300W 12U/300W 12U/300W 8U/300W 11U/300W 8U/300W 29U 24U 29U 29U 24U 10U

* Remarks: ESS - Energy Storage System; ICC - Integrated Controller & Converter.

05

Global Applications

Diesel Hybrid for Indonesia Mitratel Diesel Hybrid for Nigeria Starcomms Diesel Hybrid for Uganda WaridDiesel Hybrid for Nigeria MTN Diesel Hybrid for South Africa Vodacom

Solar Hybrid for Mali Sotelma Solar Hybrid for Pakistan CMPAKSolar Hybrid for Nepal Ncell Solar Hybrid for South Africa Vodacom Solar Hybrid for Saudi Arabia STC

Solar Hybrid for Guatemala ClaroSolar Hybrid for Ghana VDF Solar Hybrid for Japan Eaccess Solar Hybrid for Kenya SafaricomSolar Hybrid for Egypt Etisalat

Diesel Hybrid for Indonesia HCPT Diesel Hybrid for Sudan MTNDiesel Hybrid for Ghana MTN Diesel Hybrid for Nepal NcellDiesel Hybrid for Angola Unitel

Solar Hybrid for Bangladesh Cambodia CamGSMSolar Hybrid for Botswana BTC Solar Hybrid for Chile Nextel Solar Hybrid for China UnicomSolar Hybrid for Bangladesh Grameenphone

Grid Hybrid for Pakistan MobilinkSolar Hybrid for DU in U.A.E Grid Hybrid for Nigeria Zain Grid Hybrid for Pakistan CMPAKSolar Hybrid for Turkey Vodafone

06

Copyright © Huawei Technologies Co., Ltd. 2013. All rights reserved.

No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.

General Disclaimer

The information in this document may contain predictive statements including,

without limitation, statements regarding the future financial and operating results,

future product portfolio, new technology, etc. There are a number of factors

that could cause actual results and developments to differ materially from those

expressed or implied in the predictive statements. Therefore, such information

is provided for reference purpose only and constitutes neither an offer nor an

acceptance. Huawei may change the information at any time without notice.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Industrial Base

Bantian Longgang

Shenzhen 518129, P.R. China

Tel: +86-755-28780808

Version No.: M3-022334-20130220-C-2.0

www.huawei.com

Trademark Notice

, HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd.

Other trademarks, product, service and company names mentioned are the property of their respective owners.

Global Application:

Cumulative sales volume: • 24,000 sets; Number of countries: 89; Number of operators: 110+

Award:

In June 2012, Huawei site energy solution won the “GreenTech Award” on CommunicAsia2012. •

In January 2012, DTAG awarded Huawei the “Site Design Beauty Merit Prize” certification. •

In June 2010, Huawei teamed up with VDF at "green site" solutions, winning the fourth Global Telecom Business •

Innovation Award.

In March 2010, at the Third Forum on Green Communication and Energy Conservation, Huawei won 2009-2010 •

Enterprise-level Technological Innovation Award for Green Communication and Energy Conservation.

In March 2010, at the Third Forum on Green Communication and Energy Conservation, Huawei's green site •

solution won 2009-2010 Excellent Solution Award for Green Communication.

In November 2009, GSMA granted Huawei and Grameenphone, ( a subsidiary of Telenor in Bangladesh) the "Green •

Mobility Award" in recognition of the two companies close cooperation in building green networks and reducing

carbon emission, setting new benchmarks for the industry.