How to select a DIN rail power supply
-
Upload
asiez -
Category
Technology
-
view
335 -
download
5
description
Transcript of How to select a DIN rail power supply
![Page 1: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/1.jpg)
What to Look for When Choosing a
Power Supply
www.asi-ez.com 877-650-5160 1
Automation Systems Interconnect
Safety, reliability, and power factor
correction are among the prime
considerations
![Page 2: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/2.jpg)
www.asi-ez.com 877-650-5160 2
Safety
First One of the most fundamental and often overlooked purposes of a power supply is to provide isolation and therefore safety from a high-voltage (or dangerous) supply line
![Page 3: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/3.jpg)
Reliability
3
www.asi-ez.com 877-650-5160
Q: What Affects the Reliability of a Power Supply?
A: - Average load rate- Vibration- Ambient Temperature
![Page 4: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/4.jpg)
www.asi-ez.com 877-650-5160 4
Key issue is the amount of heat generated by the internal components
ASI Power Supply Designed with Excellent Ventilation toAvoid Overheating
![Page 5: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/5.jpg)
Mean Time Between Failure (MTBF)
www.asi-ez.com 877-650-5160 5
some manufacturers have developed their own proprietary calculations for MTBF that produce higher values, it is best to compare only using the MTBF as defined in MIL-HDBK-217E
![Page 6: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/6.jpg)
Power Factor Correction
www.asi-ez.com 877-650-5160 6
key performance element of a power supply
is its power factor
![Page 7: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/7.jpg)
Power Factor
Correction
www.asi-ez.com 877-650-5160 7
There are two primary methods of power factor correction (PFC). The first method is the use of a simple coil at the input, and the second involves the use of a special electronic power-factor-correction circuit. The use of the coil is referred to as "passive" PFC and it typically produces a power factor of 0.7 to 0.8. The best use of the available energy with the least amount of conducted harmonics can be achieved with "active" PFC.
![Page 8: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/8.jpg)
“Active” PFCActive PFC can produce a power factor greater than 95% and is most useful in
larger power supplies, 24 Vdc at 10 A and higher, since the conducted harmonics are directly proportional to the current load.
www.asi-ez.com 877-650-5160 8
Power Factor
Correction
![Page 9: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/9.jpg)
Look for the power supply to also meet the EN 55011-B and EN55022-B specification for electrical emissions and EN 61000.3.2 regarding harmonic emissions conducted back on the main input lines.
www.asi-ez.com 877-650-5160 9
Power Factor
Correction
![Page 10: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/10.jpg)
Surge Protection
www.asi-ez.com 877-650-5160 10
This built-in feature (up to 4 kV of protection) saves valuable panel space by not requiring an external suppressor
![Page 11: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/11.jpg)
A good power supply is one that offers a minimum of 5%, and ideally 10% of overload protection.
www.asi-ez.com 877-650-5160 11
![Page 12: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/12.jpg)
Short-circuit protection:- For Safety Purposes
- Saves time in powering up after a short circuit
has been detected
www.asi-ez.com 877-650-5160 12
![Page 13: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/13.jpg)
Agency Approvals
www.asi-ez.com 877-650-5160 13
UL, CSA, and CE compliance marks are
evidence of passing several safety and
electrical emissions requirements
![Page 14: How to select a DIN rail power supply](https://reader033.fdocuments.net/reader033/viewer/2022052410/555be59ed8b42a38078b4ed1/html5/thumbnails/14.jpg)
Agency Approvals
www.asi-ez.com 877-650-5160 14
The UL 508 listing offers the additional benefit of not requiring a power supply
rated for twice the intended use. Without UL 508, the power supply must be
derated by 50% in order for the control cabinet to also be UL 508 compliant.