4'-8"

5'-8"

3'-9"

3'-9"

5'-4"6'-0"5'-6"

5'-0" 4'-0" 8'-10"16'-8"

9'-4"

13'-2"

(2)2"x12" BEAM

(2)2"x12" BEAM

(2

)2

"x1

2" B

EA

M

(2

)2

"x1

2" B

EA

M

8"x1

6" M

AS

ON

RY

PIE

RS

, T

YP

.

241

241

241

STEP DOWN INTO

GARAGE (VERIFY HT.)

REINFORCED

CONC. SLAB

208

10'-0"

5'-0"

REINFORCED

CONC. SLAB

1/8

" P

ER

F

OO

T

SL

OP

E D

OW

N

1/8

" P

ER

F

OO

T

SL

OP

E D

OW

N

1/8

" P

ER

F

OO

T

SL

OP

E D

OW

N

REINFORCED

CONC. SLAB

16'-6" 23'-0"

2'-6"

18'-0" (VERIFY W/ UNIT SELECTED)

2'-6"

2X12 FLR. JSTS.

@ 16" O.C.

2X12 FLR. JSTS.

@ 24" O.C.

2X12 FLR. JSTS.

@ 24" O.C.

2X12 FLR. JSTS.

@ 24" O.C.

LEVEL

FLOOR

START SLOPE HERE

AS REQ'D

UPSET

AS REQ'D

UPSET

2X

12

B

AN

D (T

YP

.)

3'-0"

3'-0"

11'-4"

11'-4"

11'-4"

3'-0" 3'-0"13'-8" 16'-9"

(TO BE LOCATED BY OWNER)

ACCESS DOOR

3'-0"

3'-0"

8'-3"

8'-3"

16" LO

NG

, 8" T

ALL

TY

P. B

RIC

K V

EN

T

16" LONG, 8" TALL

TYP. BRICK VENT

2X

12

B

AN

D (T

YP

.)

7'-6"

22'-6"

1'-0"

3'-0"

18'-0"

22'-0"

29'-6"

3'-1"

22'-10"16'-8"

39'-6"

40'-0"

5'-0"

45'-0"

7'-0"

52'-0"

39'-6"

240

242

240

225

225

240

240

240

221

221

221

222

221

242

242

242

242

2X12 FLR. JSTS.

@ 16" O.C.

CRAWLSPACE FOUNDATIONSCALE: =============== 1/4" = 1'-0"

DET. 240

REINFORCING, AS REQ'D BY CODE

1/2" DIA. ANCHOR BOLT @8'-0" O.C., MAX.

PRE-ENGINEERED TRUSSES

FLOOR JOISTS OR

3/4" STUR DI-FLOR

2" X TREATED SILL PLATE

@32" O.C.

SEEP HOLES

2 x HEADER

8" X 16" BRICK VENT

AWAY FROM BLDG.

FIN. GRADE, SLOPE

2'-0"

1'-0"

BRICK (OPTIONAL)

3-#4 BARS, CONT., W/ #4 TIES @36" O.C.

8" CONC. BLK., FILLED W/ CONC.

MAS. JT. REINF. @ 16" O.C., VERT.

UN-DISTURBED SOIL LINE

TERMITE SHIELD

INSUL. BD., SEE SPECS.

INSULATION

(OR AS REQ'D BY LOCAL CODE.)

(OR AS REQ'D BY LOCAL CODE.)

1'-0"

UN-DISTURBED SOIL LINE

2'-0"

DET. 241

REINFORCING, AS REQ'D BY CODE

PRE-ENGINEERED TRUSSES

3/4" STUR DI-FLOR

3-#4 BARS, CONT., W/ #4 TIES @36" O.C.

8" CONC. BLK., FILLED W/ CONC.

FLOOR JOISTS OR

INSULATION

TERMITE SHIELD

w/3/4" PLYWOOD BETWEEN

(2)2" X'S GLUED AND NAILED

2" X TREATED SILL PLATE

1'-6" M

IN

.

1/2" DIA. ANCHOR BOLT

UNDISTURBED SOIL LINE

DET. 222

2'-0"

1'-0"

FILLED W/CONC.

8" CONC. BLK.,

DRIVEWAY N.I.C.

.006 POLY.

4" CONC. SLAB, REINF.

W/ 6"X6"-10/10 W.M.

3-#4 BARS, CONT., W/ #4

TIES @36" O.C. (OR AS

REQ'D BY LOCAL CODE.)

THOROUGHLY

COMPACTED FILL

REINFORCING, AS

REQ'D BY CODE

MAS. JT. REINF. @ 16"

O.C., VERT.

#4 BAR @ 12" O.C.

EXTENDED OUT FOR

DRIVEWAY

8"

2'-0"

DET. 242

VE

RIF

Y

THOROUGHLY COMPACTED FILL

.006 POLY.

1'-0"

1- #4 BAR CONT.

2" X HEADER

SEE FOUND. PLAN

BRICK, IF APPLICABLE

REINFORCING, AS REQ'D BY CODE

3-#4 BARS, CONT., W/ #4 TIES @36" O.C.

UN-DISTURBED SOIL LINE

8" CONC. BLK., FILLED W/ CONC.

MAS. JT. REINF. @ 16" O.C., VERT.

PRE-ENGINEERED TRUSSES

INSULATION BOARD

FLOOR JOISTS OR

4" CONC. BLOCK FILLED W/ CONC.

INSULATION

1/2" DIA. ANCHOR BOLT

TERMITE SHIELD

@8'-0" O.C., MAX.

2" X TREATED SILL PLATE

(OR AS REQ'D BY LOCAL CODE.)

4" CONC. SLAB REINF. W/

6X6" - 10/10 W.M.

(IF BRICK IS USED ABOVE)

BRICK SILL

DET. 225

GROUT

1'-0"

2'-0"

SEEP HOLES @32" O.C.

FIN. GRADE, SLOPE

AWAY FROM BUILDING

3-#4 BARS, CONT., W/ #4 TIES @36" O.C.

THOROUGHLY COMPACTED FILL

.006 POLY.

8" CONC. BLK.

REINFORCING, AS REQ'D BY CODE

(OR AS REQ'D BY LOCAL CODE.)

UNDISTURBED SOIL LINE

6"X6"-10/10 W.M.

4" CONC. SLAB, REINF. W/

BASE PLATE

WALL STUD MIN.

2x6 PLUMBING

WALLS

SUBFLOOR

SHEATHING

FLOOR JOIST

PLUMBING

INSIDE WALL

BLOCK DOUBLE

FLOOR JOISTS

4'-0" O.C. MAX.

PLUMBING WALL FRAMING DETAIL

HPG-

2

PROFESSIONAL

MEMBER:

SHEET NUMBER

CRAWLSPACE

1802B

665

9 H

WY

. 98

WE

ST

, HA

TT

IES

BU

RG

, MS

394

02 E

MA

IL: H

OU

SE

PL

AN

GA

LL

ER

Y@

CO

MC

AS

T.N

ET

\\

FA

X: (

601)

264

-448

3DIMENSIONS AND CONDITIONS TO BE VERIFIED BY CONTRACTOR -- © COPYRIGHTED--ANY AND ALL UNAUTHORIZED REPRODUCTION PROHIBITED

HO

US

E P

LA

N G

AL

LE

RY

, IN

C.

A.L.B.

CHECKED BY:

G.L.M.

PLAN NUMBER

DRAWN BY:

02/01/07

DATE:

FOUNDATION

24'-0"

16'-0"

4'-4" 18'-6"

13'-10" 8'-10"

7'-8"

4" CONC. SLAB, REINF. W/

6"X6"-10/10 W.M. OVER .006 POLY.

THOROUGHLY COMPACTED FILL

1'-4"

DET. 208

1'-4"

.006 POLY

MIN

.

3-#4 BARS, CONT. W/

#4 TIES @ 36" O.C.MIN.

(OR AS REQ'D BY LOCAL CODE.)

221

2'-0"

DET. 221

1'-0"

GROUT

MAS. JT. REINF. @ 16" O.C., VERT.

3-#4 BARS, CONT., W/ #4 TIES

8" CONC. BLK., FILLED W/ CONC.

UNDISTURBED SOIL LINE

INSUL. BD.

.006 POLY.

8" FORM (HEADER) BLK.

SEEP HOLES

UPSET AS REQ'D

SLOPE AWAY FROM

FROM BUILDING

FIN. GRADE,

@32" O.C.

MIN

.

4" CONC. SLAB, REINF. W/

THOROUGHLY COMPACTED FILL

6"X6"-10/10 W.M.

REINFORCING, AS REQ'D BY CODE

(OR AS REQ'D BY LOCAL CODE.)

BRICK (OPTIONAL)

8"

1/2" DIA. ANCHOR BOLTS @

8'-0" O.C., MAX.

4'-8"

STEP DOWN

ONTO PORCH

(VERIFY HT.)

52'-0"

12'-0"

10'-0"

CRAWLSPACE FOUNDATION NOTES:

1. WE RECOMMEND THAT ALL FOOTING SIZES BE VERIFIED BY A

LICENSED STRUCTURAL ENGINEER, BASED ON SOILS

ANALYSIS AT SITE, PRIOR TO CONSTRUCTION.

2. FOUNDATION SHALL COMPLY WITH ALL APPLICABLE CODES

AT SITE.

3. CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS WITH

FOUNDATION PLAN AND MAKE NECESSARY ADJUSTMENTS.

4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT SITE.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING

PROPER DRAINAGE AT SITE.

6. GLUE ALL STUR-DI-FLOR PLYWOOD TO FLOOR FRAMING

AND NAIL SECURELY W/ RING-SHANK NAILS.

7. ALL FOUNDATION DETAILS ARE TYPICAL. SOME VARIATIONS

MAY OCCUR. CONTRACTOR TO MAKE NECESSARY

ADJUSTMENTS AT SITE.

8. CONTRACTOR TO PROPERLY SLOPE PORCHES & GARAGE

AWAY FROM RESIDENCE FOR PROPER DRAINAGE.

9. CONTRACTOR TO LOCATE ACCESS DOOR @ SITE w/ OWNER.

10. ALL CONCRETE TO BE 4" (3000 psi MIN.) SLABS REINFORCED

W/ 6"x6" - 10/10 W.M.

11. PROVIDE DOUBLE JOISTS UNDER ALL WALLS RUNNING

PARALLEL TO FLOOR JOISTS.

12. ALL FLOOR JOISTS ARE TO BE 2x12 NO. 2 S.Y.P. UNLESS

OTHERWISE NOTED.

13. VERIFY THE NUMBER AND LOCATION OF BRICK VENTS WITH

APPLICABLE CODES AT SITE.

14. ALL BEAM SIZES SHALL BE VERIFIED BY LICENSED

STRUCTURAL ENGINEER.

22'-8"

6'-0"

5'-0"

3'-9"

3'-9"

Page 3: HOUSE PLAN GALLERY, INC. - Clarksville Home Builders & Sales · 2020. 1. 22. · 6659 hwy. 98 west, hattiesburg ms, 39402 email: houseplangallery@comcast.net \\ fax: (601) 264-4483

I

OF

UB

I TUTE

LD

NST

GIN

ESINGA

R

MED

IN A

CI

FLOOR PLANS

PROFESSIONAL MEMBER:

02/01/07

HO

US

E P

LA

N G

AL

LE

RY

, IN

C.

DIM

ENS

ION

S A

ND

CO

ND

ITIO

NS

TO

BE

VER

IFIE

D B

Y C

ON

TRA

CTO

R --

© C

OPY

RIG

HTE

D--A

NY

AN

D A

LL U

NA

UTH

OR

IZE

D R

EPR

OD

UC

TIO

N P

RO

HIB

ITED

SHEET NUMBER

DRAWN BY:

CHECKED BY:

DATE:

EM

AIL

: HO

US

EP

LA

NG

AL

LE

RY

@C

OM

CA

ST

.NE

T \\

FA

X: (

601)

264

-448

366

59 H

WY

. 98

WE

ST

, HA

TT

IES

BU

RG

MS

, 394

02

1802BPLAN NUMBER

HPG-

3

A.L.B.

G.L.M.

30683068

18080

24682068

2668

2868

2868

1068306810682850 WITH TRANSOM

30683636

2868

2868

3068

2068

2068

2850

2850

3068

2850

2850

2850

2850

2830

WH

D/W

UP

16" PRE-ENGINEERED FLOOR JSTSAS PER MANUFACTURER'S SPECS.

16" PRE-ENGINEERED FLOOR JSTSAS PER MANUFACTURER'S SPECS.

16" PRE-ENGINEERED FLOOR JSTSAS PER MANUFACTURER'S SPECS.

16" PRE-ENGINEERED FLOOR JSTSAS PER MANUFACTURER'S SPECS.

16" PRE-ENGINEERED FLOOR JSTSAS PER MANUFACTURER'S SPECS.

3'-8

"

8'-10" 3'-6"

8'-0" 4'-4" 4'-2"

12'-0

"4'

-2"

10'-0

"6'

-0"

5'-7

"3'

-1"

5'-8

"9'

-8"

1'-0

"3'

-0"

18'-0

"

4'-4" 8'-3" 3'-11"

8'-4" 8'-2" 2'-6" 18'-0" 2'-6"

2'-8

"7'

-8"

2'-1

0"

3'-2" 3'-2"14'-4" 2'-3"

6'-2

"7'

-7"

7'-4

"3'

-0"

2'-6

"10

'-10"

2'-8

"

3'-8

"5'

-8"

13'-2

"7'

-6"

22'-0

"

16'-6" 4'-6" 6'-0" 6'-4" 6'-2"

16'-0

"24

'-0"

16'-6" 23'-0"

39'-6"

52'-0

"

39'-6"

40'-0

"5'

-0"

7'-0

"

52'-0

"

9'-8" 8'-10"

12'-4" 4'-2" 4'-6" 18'-6"

6'-1

0"2'

-4"

4'-0

"

604

609

608607

606

603

605

601

602

MASTER BATH

6" WALL

6" W

ALL

18" TAPERED COLUMNWITH 18" STONE BASE

DRYERSPACE

9' CLG. HT.

COAT

9' CLG. HT.

SLOPEDCLG.

APPROX. 6'WALL HT.

9' CLG. HT.

16 E

QU

AL

RIS

ER

S

501

TRANSOM ABOVE

8" SQUARECOLUMN

SHELVESBELOW

MICRO.ABV.

9' CLG. HT.

9' CLG. HT.

9' CLG. HT.9' CLG. HT.

PROVIDE VENTFOR DRYER

6" WALL

RAILINGAS PERCODE

EATING BAR

42" x 72"JET TUB

CLO

SE

T

VAN

ITY

502

WASHERSPACE

UTILITY

STORAGE

TWO CAR GARAGE

COVERED PORCH

LIVING ROOM

REF. SPACE

KITCHEN

DINING ROOM

MASTERBEDROOM

ENTRY

1/2 BATH

BEAM AS PER FLOORJOISTS MANUFACTURER

FIRST FLOOR PLAN

RAILING AS PER CODE

PANTRY

GLASS BLOCK

16" P

RE

-E

NG

INE

ER

ED

FLO

OR

JS

TS A

SPE

R M

AN

UF.

'SS

PE

CS

.

SHELVES

SEAT

CUSTOMSHOWER

LINEN

3 1/2" X 15" LAM. BEAM

HPG 1802BAREAS: 1287 S.F. FIRST FLOOR HEATED

515 S.F. SECOND FLOOR HEATED1802 S.F. TOTAL HEATED 651 S.F. FIRST FLOOR UNHEATED

355 S.F. BONUS ROOM2808 S.F. TOTAL UNDER ROOF

**MASONRY NOT INCLUDED**

SCALE: 1/4" ===================== 1'-0"

SCALE: 1/4" ===================== 1'-0"

2850

2068

2868

2868

28682068

28502850

4068

3068

3068

3068

DN

ATTI

CAC

CE

SS

5'-10" 5'-10"

7'-10"

5'-8" 4'-6" 5'-8" 5'-8"

11'-6

"3'

-0"

6'-2

"

6'-1" 5'-5" 8"

6'-6" 12'-2" 3'-6"

5'-8" 11'-8" 5'-8"

6'-2

"3'

-10"

1'-8

"9'

-0"

1'-0

"1'

-0"

18'-8

"4'

-0"

12'-0

"1'

-0"

6'-6" 5'-10" 4'-6" 5'-8" 11'-4"

18'-8

"3'

-4"

20'-8

"

610

CLOSET

CLOSET

SECOND FLOOR PLAN

HALL

NOTE: CONTRACTOR TO LOCATEWATER HEATER(S) AND HVACUNITS IN ATTIC.

6" W

ALL

PORCH BELOW

501

APPROX. 6'-10"WALL HT.

SLOPEDCEILING

SLO

PED

CEI

LIN

G

SLO

PED

CEI

LIN

G

SLO

PED

CEI

LIN

G

HALL

8' CLG. HT.

8' CLG. HT.

16 E

QU

AL

RIS

ER

S

BEDROOM 2

BATH

BEDROOM 3

UNFINISHEDBONUS ROOM

502

APPROX. 6'-0"WALL HT.

APPROX. 6'-0"WALL HT.

LINEN

SCALE: 1/4" ===================== 1'-0"

32" X 60" TUB/SHWR.

SLO

PED

CEI

LIN

G

SLOPED CEILINGAPPROX. 6'-0" WALL

APPR

OX.

6'-0

" WAL

L

2X8 CLG. JSTS.@ 24" O.C.

2X8 CLG. JSTS.@ 24" O.C.

2X8 CLG. JSTS.@ 24" O.C.

ALL BEAM SIZES TO BE VERIFIED BY STRUCTURALENGINEER.

WINDOW EXAMPLE: 2840. 2'-8" WIDE BY 4'-0" TALL.DOOR EXAMPLE: 3068. 3'-0" WIDE BY 6'-8" TALL.

IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TOVERIFY CLEARANCES OF THE ITEMS MENTIONED ABOVEPRIOR TO CONSTRUCTION.

CONTRACTOR SHALL VERIFY ALL INTERIOR FINISHES, FLOORCOVERINGS, AND TRIM SIZES & CONFIGURATIONS WITHOWNER PRIOR TO CONSTRUCTION.

DOOR & WINDOW SIZES ARE GIVEN IN FEET &INCHES IN WIDTH & HEIGHT RESPECTIVELY.

CONTRACTOR TO VERIFY ALL DIMENSIONS & EXISTINGSITE CONDITIONS PRIOR TO CONSTRUCTION.

NOTES:

REFER TO EXTERIOR ELEVATIONS FOR EXTERIORWALL FINISHES.

REFER TO MANUFACTURERS SPECS FOR ROUGHOPENING DIMENSIONS, FOR DOORS AND WINDOWS.

CONTRACTOR SHALL MAKE ALL NECESSARYMODIFICATIONS DURING CONSTRUCTION PROCESSTO COMPLY WITH I.R.C. (INTERNATIONALRESIDENTIAL CODE), LATEST EDITION, ORAPPLICABLE CODES AT SITE.

Page 4: HOUSE PLAN GALLERY, INC. - Clarksville Home Builders & Sales · 2020. 1. 22. · 6659 hwy. 98 west, hattiesburg ms, 39402 email: houseplangallery@comcast.net \\ fax: (601) 264-4483
Page 5: HOUSE PLAN GALLERY, INC. - Clarksville Home Builders & Sales · 2020. 1. 22. · 6659 hwy. 98 west, hattiesburg ms, 39402 email: houseplangallery@comcast.net \\ fax: (601) 264-4483
Page 6: HOUSE PLAN GALLERY, INC. - Clarksville Home Builders & Sales · 2020. 1. 22. · 6659 hwy. 98 west, hattiesburg ms, 39402 email: houseplangallery@comcast.net \\ fax: (601) 264-4483
Page 7: HOUSE PLAN GALLERY, INC. - Clarksville Home Builders & Sales · 2020. 1. 22. · 6659 hwy. 98 west, hattiesburg ms, 39402 email: houseplangallery@comcast.net \\ fax: (601) 264-4483

I

OF

UB

I TUTE

LD

NST

GIN

ESINGA

R

MED

IN A

CI

ELECTRICAL PLANS

PROFESSIONAL MEMBER:

02/01/07

HO

US

E P

LA

N G

AL

LE

RY

, IN

C.

DIM

ENS

ION

S A

ND

CO

ND

ITIO

NS

TO

BE

VER

IFIE

D B

Y C

ON

TRA

CTO

R --

© C

OPY

RIG

HTE

D--A

NY

AN

D A

LL U

NA

UTH

OR

IZE

D R

EPR

OD

UC

TIO

N P

RO

HIB

ITED

SHEET NUMBER

DRAWN BY:

CHECKED BY:

DATE:

EM

AIL

: HO

US

EP

LA

NG

AL

LE

RY

@C

OM

CA

ST

.NE

T \\

FA

X: (

601)

264

-448

366

59 H

WY

. 98

WE

ST

, HA

TT

IES

BU

RG

MS

, 394

02

1802BPLAN NUMBER

HPG-

7

A.L.B.

G.L.M.

WH

D/W

UP

CLG. PLUG

SD

R R

RR

RR

R R

RR

SD

R

WP

WP

GFCI

3 3

WP

33 3

GFCI

WP

3

WP

GFCIGFCI

GFCI

WP

GFCI

WP

3

WP

33

WP

WP

WP

WP

3

WP

GFCI

GFCI

3

FLUORESCENTFIXTURE

220 VOLT

FLUORESCENTFIXTURE

FLU

OR

ESC

EN

TFI

XTU

RE

FLU

OR

ESC

EN

TFI

XTU

RE

220 VOLT

FLUORESCENT

LINEN

VERIFY LOCATIONWITH OWNER

RAISED BAR

TO SWITCHUPSTAIRS

220 VOLT PLUG FOR MICRO. ABV.

REF.

COVERED PORCH

TWO CAR GARAGE

UTILITY STORAGE

ENTRY

MASTER BEDROOM

MASTERBATH

JET TUB

PLUG FOR JET TUB

LIVING ROOM

DINING ROOM

KITCHEN

PANTRY SHOWER

CLO

SE

T

SWITCH FORDISPOSAL

DN

ATTI

CAC

CE

SS

SD

SD

SD

SD

3

GFCIGFCI

3

TO S

WIT

CH

DO

WN

STAI

RS

ATTI

C A

CC

ESS

BEDROOM 2

BEDROOM 3

HALL

HALLCLOSET

BATH

CLOSET

32" X 60" TUB/SHWR.TO LIGHTIN ATTIC

SD

R

WP

3

4

DM

GFCI

TV

T

LIVING AREA

WALL SCONCE

CEILING EXHAUST FAN

THERMOSTAT (VERIFY LOCATIONS)

DOORBELL BUTTON

TELEVISION OUTLET

TELEPHONE OUTLET

DIMMER SWITCH

FOUR WAY SWITCH

THREE WAY SWITCH

SWITCH

SMOKE DETECTOR

FLUORESCENT LIGHT

RECESSED CEILING FIXTURE

OVERHANG MOUNTED FLOODLIGHTS

CEILING HUNG FIXTURE

FLOOR OUTLET

220 VOLT RECEPTACLE

WEATHERPROOF OUTLET

GROUND FAULT PROTECTED OUTLET

110 VOLT OUTLET

DESCRIPTIONSYMBOL

ELECTRICAL SYMBOLS LEGEND

CEILING FAN W/ LIGHT

CEILING EXHAUST FAN W/ LIGHT

(VERIFY LOCATIONS W/ OWNER)

(VERIFY LOCATIONS W/ OWNER)

(VERIFY LOCATIONS W/ OWNER)

WALL MOUNTED LIGHT FIXTURE

ELECTRICAL CONTRACTOR TO VERIFY ALLEXISTING SITE CONDITIONS & MAKE ANYNECESSARY ADJUSTMENTS.

P PILOT SWITCH

SMALLEST WIRE SIZE TO BE 12-2.

ALL WORK SHALL COMPLY WITH THE NATIONALELECTRIC CODE & ANY OTHER APPLICABLEREGULATIONS OR CODES, AT THE SITE.

ALL SMOKE DETECTORS TO BE HARD-WIREDTOGETHER WITH BATTERY BACKUP.

CONTRACTOR TO LOCATE PHONE, CABLE, ETC. ASPER OWNER'S SPECIFICATIONS.