HOUSE #128 - Hingham, MA

1
143 LF OF 6" SDR 35 PVC AT 2.0% ESMH1 RIM: 67.76 INV: 61.85 (IN #128) BRICK SHELF: 61.76 INV: 60.93 (OUT (EXISTING) INV OUT: 64.91 PROPOSED HOUSE #128 PROPOSED ACCESSORY STRUCTURE (BARN) FFE: 72.0 SETBACK PROPERTY LINE FFE: 75.0± BASEMENT: 66.0 INV: 65.30 SAWCUT EXISTING PAVEMENT REPAIR SIDEWALK IN KIND. CO PROVIDE CLEANOUT AT PROPERTY LINE AS "VIEWING PORT" PER TOWN OF HINGHAM STANDARDS INV: 62.63 DECOMMISSIONED SHALLOW WELL (NOT IN USE) 70 WATER SERVICE (SIZE TBD) SERVICE TAP PER AQUARIAN REQUIREMENTS W HERSEY STREET (PUBLIC WAY) EDGE OF PAVEMENT PAVED DRIVEWAY LIMIT OF 200-FOOT MWRA DISTRICT BUFFER CO 10' MIN DECK COVERED PORCH 71.67 71.0 71.00 71.25 71 72 PAVED WALKWAY GRASS PAVE PATH TO BARN SHED TO BE REMOVED EXISTING LEDGE KNOB TO BE CUT DOWN TO ACCOMMODATE DRIVABLE PATH TO BARN 72 71 70 69 70 UNDERGROUND DETENTION SYSTEM #1 56 CHAMBERS, STORMTECH SC-160LP OR EQUAL BOTTOM OF STONE: 67.0 UNDERGROUND DETENTION SYSTEM #2 48 CHAMBERS, STORMTECH SC-160LP OR EQUAL BOTTOM OF STONE: 66.0 PIPE OUTLET. PROVIDE RIP-RAP OUTFALL MIN 5-FT LENGTH FROM PIPE END INVERT: 65.50 HEADER PIPE SEE OUTLET DETAIL 6" AREA DRAIN PROVIDE LANDSCAPE "DOME" GRATE" RIM: 69.50 INV: 67.60 (6" PVC OUT) INV IN: 67.50 CLEANOUT SET 6" BELOW FG CLEANOUT SET 6" BELOW FG PROVIDE 6" INLINE AREA DRAIN BELOW THE DECK INV: 68.0 EXPOSED FOUNDATION DROP FOUNDATION AS NEEDED TO MAINTAIN FROST PROTECTION 50LF OF 8" HDPE AT 0.5% 110LF OF 8" HDPE AT 0.5% 8" HEADER PIPE SET LEVEL AT 67.50 8" HEADER INV: 68.0 42.2' 42.0' 60.0' 54.5' RIVERSTONE DRIP STRIP SEE DETAIL RIVERSTONE DRIP STRIP SEE DETAIL 12.5 LF SEWER STUB PER PLUMBING CODE 2.0% MIN SLOPE 33.9' 16.8' 15.7' 123.2' 45.1' INSPECTION PORT TYPICAL OF 9 BURY 6" BELOW FG RIVERSTONE DRIP EDGE NO PIPE NEEDED 70 G G ETC ETC PROPOSED UNDERGROUND ELECTRIC & DATA SERVICE COORDINATE WITH LOCAL ELECTRIC COMPANY GAS SERVICE HAYBALE (OR STRAW WADDLE) AND SILT FENCE (TYPICAL) 71 71.9 63.00 59.10 59.10 63.00 54.10 55.2 58.00 58.00 68 70 71 72 PROPOSED BLOCK WALL SET 1-FOOT OFF PROPERTY LINE HEIGHT SHALL NOT EXCEED 4 FEET EROSION CONTROL TO CONTINUE AROUND LIMIT OF WORK AT PROPOSED RETAINING WALLS NOT SHOWN FOR GRAPHIC PURPOSES EROSION CONTROL TO CONTINUE AROUND LIMIT OF WORK AT PROPOSED RETAINING WALLS NOT SHOWN FOR GRAPHIC PURPOSES 6.0' INV: 71.0 INV: 69.0 INV: 68.2 CREATE 6"-12" HIGH LANDSCAPE BERM TO DIRECT RUNOFF TOWARDS STREET PROVIDE TEMPORARY CONSTRUCTION ENTRANCE 3" CRUSHED STONE, 6" DEEP MINIMUM 18' WIDE x 40' LONG, MINIMUM MAINTAIN PAVED SIDEWALK CLEAR OF DEBRIS AT ALL TIME 58.00 58.00 TP-2 TP-3 TP-1 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 59 58 0+00 0+50 1+00 1+50 EXISTING GRADE PROPOSED GRADE 143 LF OF 6" SDR 35 PVC AT 2.0% ESMH 1 RIM: 67.76 4' MIN COVER PROPOSED HOUSE FFE: 75± 1+80 PROPOSED CLEANOUT PROPOSED CLEANOUT SET 6" BELOW FG SEWER INSTALLED PER APPLICABLE PLUMBING CODES 10-FEET FROM BUILDING 2.0% SLOPE BASEMENT PROPERTY LINE EXISTING BUILDING EXISTING WATER SERVICE PROPOSED SEWER EXISTING CONTOUR LINE S PROPOSED DOMESTIC WATER PROPERTY SETBACK EXISTING SEWER SERVICE PROPOSED CONTOUR LINE 102 SEWER MANHOLE PROPOSED BUILDING PROPOSED SPOT GRADE 81.61 PROPOSED CLEAN OUT LEGEND PVI SITE DESIGN PVI Site Design, LLC Civil Engineering - Land Entitlements Master Planning - Project Management 339-206-1030 JOB NO: CHECKED: DRAWN: FILE: SCALE: 128 HERSEY ST, HINGHAM, MA 02043 142 HERSEY ST, HINGHAM, MA 02043 JULIET FULGONI REV.: SEAL: PROPOSED HOUSE SHEET NO: ISSUED FOR PERMIT C100 PROPOSED SEWER CONNECTION JULY 14, 2020 PROJECT: CLIENT / APPLICANT: CONSULTANT: TOP COURSE BINDER COURSE GRAVEL BASE 1' DIA. 1' 6" DIA. 1' 4' MIN. 3 4 " CRUSED STONE MECHANICALLY COMPACTED IN 6" LIFTS 6" SEWER SERVICE ORDINARY FILL MATERIAL COMPACTED IN 6" LIFTS TO ACHIEVE MIN. 90% MAX. DRY DENSITY. NO STONES LARGER THAN 2" DIAMETER SEE PAVEMENT SECTION, LANDSCAPING OR TRENCH PATCH DETAIL AS APPROPRIATE 4 TYPICAL CLEAN OUT ASSEMBLY NOT TO SCALE FLOW 4" PVC CLEANOUT RISER STACK 4" PVC 45° BEND SEE TYPICAL PIPE TRENCH DETAIL FOR BEDDING 6"x6"x4"WYE 7 PLAN VIEW SCALE: 1"=20' 20' 0' 10' 40' 8 SEWER PROFILE SCALE H: 1"=20', V:1"=2' GENERAL NOTES: 1. EXISTING CONDITIONS INFORMATION IS REPRODUCED FROM THE EXISTING CONDITIONS PLAN PREPARED BY NANTASKET SURVEY & ENGINEERING, LLC DATED AUGUST 6, 2020. 2. SCREENED IMAGES SHOW EXISTING CONDITIONS. WHERE EXISTING CONDITIONS LIE UNDER OR ARE IMPINGED UPON BY PROPOSED BUILDINGS AND/OR SITE ELEMENTS, THE EXISTING CONDITION WILL BE REMOVED, ABANDONED AND/OR CAPPED OR DEMOLISHED AS REQUIRED. 3. THE LOCATIONS OF UNDERGROUND UTILITIES SHOWN ARE BASED ON THE SURVEY REFERENCED ABOVE. PRIOR TO THE START OF ANY EXCAVATION, THE CONTRACTOR SHALL NOTIFY DIGSAFE AND THE PROPER LOCAL AUTHORITIES OR RESPECTIVE UTILITY COMPANIES TO CONFIRM THE LOCATION OF ALL EXISTING UTILITIES. ANY DAMAGE DUE TO FAILURE OF THE CONTRACTOR TO CONTACT THE PROPER AUTHORITIES SHALL BE BORNE BY THE CONTRACTOR. 4. CONTRACTOR SHALL THOROUGHLY FAMILIARIZE THEMSELVES WITH ALL CONSTRUCTION DOCUMENTS, SPECIFICATIONS AND SITE CONDITIONS PRIOR TO BIDDING AND PRIOR TO CONSTRUCTION. 5. ANY DISCREPANCIES BETWEEN DRAWINGS, SPECIFICATIONS, AND SITE CONDITIONS SHALL BE REPORTED IMMEDIATELY TO THE OWNER'S REPRESENTATIVE FOR CLARIFICATION AND RESOLUTION PRIOR TO BIDDING OR CONSTRUCTION. 6. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING CONDITIONS TO REMAIN THAT ARE DUE TO CONTRACTOR OPERATIONS. 7. ALL ITEMS TO BE REMOVED THAT ARE NOT STOCKPILED FOR LATER REUSE ON THE PROJECT OR DELIVERED TO THE OWNER SHALL BE LEGALLY DISPOSED OF BY THE CONTRACTOR. 8. THE CONTRACTOR SHALL COORDINATE ALL ADJUSTMENT OR ABANDONMENT OF UTILITIES WITH THE RESPECTIVE UTILITY COMPANY. 9. ELECTRIC AND GAS SERVICE ARE SHOWN FOR COORDINATION PURPOSES ONLY. CONTRACTOR SHALL CONTACT LOCAL UTILITY COMPANY TO COORDINATE FINAL CONNECTION POINTS. SEWER NOTES: 1. WHERE AN EXISTING UTILITY IS FOUND TO CONFLICT WITH THE PROPOSED WORK, THE LOCATION, ELEVATION, AND SIZE OF THE UTILITY SHALL BE ACCURATELY DETERMINED WITHOUT DELAY BY THE CONTRACTOR, AND THE INFORMATION FURNISHED TO THE ENGINEER FOR RESOLUTION OF THE CONFLICT. 2. ALL WORK SHALL CONFORM TO THE TOWN OF HINGHAM SEWER RULES AND REGULATIONS AND SPECIFICATIONS. RULES AND REGULATIONS ARE AVAILABLE AT WWW.HINGHAM-MA.GOV 3. ALL SEWER PIPES SHALL BE PVC PER ASTM D3034, SDR-35 AND ASTM D1784 WITH RUBBER GASKET JOINTS. 4. CONTRACTOR SHALL PROVIDE ALL FITTINGS, BENDS, RESTRAINTS, THRUST BLOCKS, AND OTHER APPURTENANCES NECESSARY FOR INSTALLATION OF WATER SERVICE WHETHER SPECIFICALLY NOTED OR NOT. 5. THE MINIMUM ALLOWABLE SLOPE SHALL BE 2.0% 6. SURFACE WATER, GROUNDWATER FROM SUMP PUMPS, ROOF DOWNSPOUTS AND OTHER STORMWATER PIPED SYSTEMS SHALL NOT BE DISCHARGED TO THE SEWER. 7. THE SEWER SHALL BE INSTALLED BY A HINGHAM LICENSED DRAINLAYER. 8. AN AS-BUILT DRAWING SHALL BE SUBMITTED TO THE TOWN OF HINGHAM WITHIN 10-DAYS OF INSTALLATION OF THE SEWER SYSTEM AND PRIOR TO ANY FINAL APPROVAL. THE CONTRACTOR IS RESPONSIBLE FOR DOCUMENTING ANY VARIATION TO THE DESIGN AND PROVIDE INFORMAITON TO THE ENGINEER OF RECORD. TRACER TAPE GREEN, 3" WIDE (MIN) LABELED "BURIED SEWER LINE BELOW" 12"± 6" LOAM PROVIDE DETECTABLE, THREADED CAP BURIED 6" (MAX) BELOW FINISH GRADE INSPECTION REQUIREMENTS: 1. NOTIFY THE TOWN OF HINGHAM BOARD OF SEWER COMMISSIONERS THREE (3) BUSINESS DAYS PRIOR TO INSTALLATION OF THE SEWER SERVICE. 2. IF A DESIGN CERTIFICATION IS REQUIRED, THE ENGINEER OF RECORD SHALL BE NOTIFIED (3) BUSINESS DAYS PRIOR TO INSTALLATION OF THE SEWER SERVICE. 3. ALL INSPECTIONS SHALL BE PERFORMED PRIOR TO BACK-FILL. 3 1 8 " C B A COMPACTED SUBGRADE COMPACTED GRAVEL BASE BINDER COURSE SURFACE COURSE BIT. CONCRETE WALK BIT. CONCRETE ROAD A B C 6" 1 1/2" 1" 12" 2" 1" 5 ASPHALT PAVEMENT NOT TO SCALE 3 TYPICAL PIPE TRENCH NOT TO SCALE 1: 08-31-2020 SEW. COMMISSION COMMENTS DRAINAGE NOTES: 1. DETENTION SYSTEM CHAMBERS MAYBE RE-CONFIGURED TO AVOID SITE CONSTRAINTS. TOTAL NUMBER OF CHAMBERS SHALL MATCH IF CONFIGURATION IS CHANGED. 2. IF GUTTERS AND DOWNSPOUTS ARE UTILIZED, THE 6" COLLECTION PIPE SHALL BE SOLID WALL PIPE. IF CRUSHED STONE DRIP STRIPS ARE UTILIZED, 6" COLLECTION PIPE SHALL BE PERFORATED PIPE WRAPPED IN FILTER FABRIC FOR THE LENGTH OF THE DRIP-STRIP TO INTERCEPT RUNOFF WITH A CLEAN OUT AT THE UPSTREAM END. 3. ALL CLEAN OUT COVERS IN LANDSCAPED AREAS SHALL BE SET 6" BELOW FINISH GRADE AND AS-BUILT LOCATIONS PROVIDED TO THE ENGINEER FOR RECORD. 4. CONTRACTOR SHALL PROVIDE AS-BUILT SWING TIE INFORMATION FOR DETENTION SYSTEMS TO THE OWNER AND OWNER'S ENGINEER FOR RECORD PURPOSES. WEED INHIBITING FABRIC BUILDING FACE 3 4 " TO 1-1/2" DIA. WASHED DRAINAGE AGGREGATE. TAMP TO DEPTH OF 5" (MIN.). VARIES, ADJUST TO MEET ROOF OVERHANG 24"MIN 36" TYPICAL 6" DIA. PERFORATED PVC PIPE, WRAP WITH FILTER FABRIC, CONNECT TO NEAREST DRAINAGE SYSTEM, TYP. SEE PLAN FOR LOCATIONS 3" 3/4" WASHED DECORATIVE RIVER STONE COMPACTED ORDINARY BACKFILL 12" MIN 6 RIVERSTONE DRIP STRIP NOT TO SCALE 67.50 67.00 69.00 SYSTEM ELEVATIONS CHAMBER NOTES: 1. CHAMBERS SHALL BE STORMTECH CHAMBER SC-160LP OR EQUAL. 2. CHAMBERS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F2418 "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS", OR ASTM F2922 "STANDARD SPECIFICATION FOR POLYETHYLENE (PE) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS" 3. CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". *TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR, INCREASE COVER TO 20" (510 mm). PAVEMENT LAYER SEE TYPICAL DETAIL SUBGRADE SOILS PERIMETER STONE (SEE NOTE 4) EXCAVATION WALL (CAN BE SLOPED OR VERTICAL) SC-160LP END CAP NO SPACING REQUIRED BETWEEN CHAMBERS 12" 14" MIN* 10' MAX 6" MIN 12" MIN 25" 12" TYP 6" BASE STONE ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALL AROUND CLEAN, CRUSHED, ANGULAR STONE #1 66.50 66.00 68.00 #2 1 TYPICAL UNDERGROUND CHAMBER SYSTEM NOT TO SCALE 6" HEADER INV: 66.00 4" OUTLET INV: 67.00 4" OUTLET INV: 67.17 HIGH OUTLET PIPE FROM ADJACENT CHAMBERS SYSTEM 2 OUTLET ELEVATIONS 8" HEADER INV: 67.50 3" OUTLET INV: 68.00 TWO (2) 3" OUTLETS INV: 68.25 SYSTEM 1 2 CHAMBER OUTLET DETAIL NOT TO SCALE 2: 04-12-2021 ISSUED FOR SITE PLAN APPROVAL AS-BUILT NOTE: CONTRACTOR SHALL PREPARE, OR COORDINATE WITH THE LAND SURVEYOR OR ENGINEER TO PREPARE, AN AS-BUILT PLAN OF ALL PROPOSED SITE IMPROVEMENTS AND UNDERGROUND UTILITIES. THE PLAN SHALL INCLUDE SWING TIES TO UNDERGROUND DETENTION SYSTEMS. AS-BUILT PLAN MUST BE SUBMITTED TO THE TOWN PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. BUILDING GSF HOUSE: BARN: 1,772 3,200 LOT AREA: 37,680 SF 20,000 SF SETBACKS: FRONT: SIDE: REAR: 25' 15' 15' 45.1' 16.8' 15.7' FRONTAGE: 125' 179.78' PROPOSED REQUIRED ZONING TABLE - RESIDENCE A 3: 05-18-2021 PEER REVIEW COMMENTS 4: 05-19-2021 SOIL TESTING SOIL LOGS DEPTH HORIZ SOIL TYPE TP-1 EG: 70.6 12" A LOAM 18" B SANDY LOAM 68" C FINE SAND REFUSAL: 64.93 TP-2 EG: 70.0 46" - FILL 42" A LOAM 69" C FINE SAND REFUSAL: 64.25 TP-13 EG: 68.0 12" A LOAM 24" B SANDY LOAM 48" C FINE SAND REFUSAL: 64.00

Transcript of HOUSE #128 - Hingham, MA

143

LF O

F 6"

SDR

35

PVC

AT 2

.0%

ESMH1RIM: 67.76INV: 61.85 (IN #128)BRICK SHELF: 61.76INV: 60.93 (OUT (EXISTING)

INV OUT:64.91

PROPOSEDHOUSE

#128

PROPOSEDACCESSORYSTRUCTURE

(BARN)FFE: 72.0

SETBACK

PROPERTY LINE

FFE: 75.0±BASEMENT: 66.0

INV: 65.30

SAWCUT EXISTING PAVEMENTREPAIR SIDEWALK IN KIND.

CO

PROVIDE CLEANOUT AT PROPERTYLINE AS "VIEWING PORT"PER TOWN OF HINGHAM STANDARDSINV: 62.63

DECOMMISSIONEDSHALLOW WELL

(NOT IN USE) 70

WATER SERVICE(SIZE TBD)

SERVICE TAP PERAQUARIANREQUIREMENTS

W

HERSEY STREET(PUBLIC WAY)

EDG

E O

F PA

VEM

ENT

PAVEDDRIVEWAY

LIMIT OF 200-FOOT MWRA DISTRICT BUFFER

CO

10' MIN DECK

COVERED PORCH71.67

71.0

71.00

71.2571

72

PAVED WALKWAY

GRASS PAVE PATHTO BARN

SHED TO BE REMOVED

EXISTING LEDGE KNOB TO BE CUTDOWN TO ACCOMMODATE DRIVABLEPATH TO BARN

72

71

7069

70

UNDERGROUND DETENTION SYSTEM #156 CHAMBERS, STORMTECH SC-160LPOR EQUALBOTTOM OF STONE: 67.0

UNDERGROUND DETENTION SYSTEM #248 CHAMBERS, STORMTECH SC-160LPOR EQUALBOTTOM OF STONE: 66.0

PIPE OUTLET.PROVIDE RIP-RAP OUTFALL MIN5-FT LENGTH FROM PIPE ENDINVERT: 65.50

HEADER PIPESEE OUTLET

DETAIL

6" AREA DRAINPROVIDE LANDSCAPE "DOME" GRATE"RIM: 69.50INV: 67.60 (6" PVC OUT)

INV IN:67.50

CLEANOUTSET 6" BELOW FG

CLEANOUTSET 6" BELOW FG

PROVIDE 6" INLINE AREADRAIN BELOW THE DECK

INV: 68.0

EXPOSED FOUNDATIONDROP FOUNDATION ASNEEDED TO MAINTAIN FROSTPROTECTION

50LF OF 8" HDPE

AT 0.5%

110L

F O

F 8"

HD

PE A

T 0.

5%

8" HEADER PIPESET LEVEL AT 67.50

8" HEADERINV: 68.0

42.2

'

42.0'

60.0

'

54.5'

RIVERSTONE DRIP STRIPSEE DETAIL

RIVERSTONE DRIP STRIPSEE DETAIL

12.5 LF SEWER STUB PERPLUMBING CODE

2.0% MIN SLOPE33.9'

16.8'

15.7'

123.2'

45.1

'

INSPECTION PORTTYPICAL OF 9BURY 6" BELOW FG

RIVERSTONE DRIP EDGENO PIPE NEEDED

70

G

GET

C

ETC

PROPOSED UNDERGROUND ELECTRIC & DATA SERVICECOORDINATE WITH LOCAL ELECTRIC COMPANY

GAS SERVICE

HAYBALE (OR STRAWWADDLE) AND SILT FENCE(TYPICAL)

71

71.9

63.00

59.10

59.10

63.00

54.10

55.2

58.00

58.00

68

70

7172

PROPOSED BLOCK WALLSET 1-FOOT OFF PROPERTY LINE

HEIGHT SHALL NOT EXCEED 4 FEET

EROSION CONTROL TO CONTINUEAROUND LIMIT OF WORK AT

PROPOSED RETAINING WALLSNOT SHOWN FOR GRAPHIC

PURPOSES

EROSION CONTROL TO CONTINUEAROUND LIMIT OF WORK ATPROPOSED RETAINING WALLSNOT SHOWN FOR GRAPHICPURPOSES

6.0'

INV: 71.0

INV: 69.0

INV: 68.2

CREATE 6"-12" HIGHLANDSCAPE BERM TO DIRECT

RUNOFF TOWARDS STREET

PROVIDE TEMPORARYCONSTRUCTION ENTRANCE3" CRUSHED STONE, 6" DEEP MINIMUM18' WIDE x 40' LONG, MINIMUMMAINTAIN PAVED SIDEWALKCLEAR OF DEBRIS AT ALL TIME

58.00

58.00

TP-2

TP-3

TP-1

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

59

58

0+00 0+50 1+00 1+50

EXISTING GRADE

PROPOSED GRADE

143 LF OF 6" SDR 35 PVC AT 2.0%

ESMH 1RIM: 67.76

4' M

IN C

OV

ER

PRO

POSE

D H

OU

SE

FFE: 75±

1+80

PROPOSED CLEANOUT

PROPOSED CLEANOUTSET 6" BELOW FG

SEWER INSTALLED PERAPPLICABLE PLUMBING CODES

10-FEET FROM BUILDING2.0% SLOPE

BASEMENT

PROPERTY LINE

EXISTING BUILDINGEXISTING WATER SERVICE

PROPOSED SEWER

EXISTING CONTOUR LINE

SPROPOSED DOMESTIC WATER

PROPERTY SETBACK

EXISTING SEWER SERVICE

PROPOSED CONTOUR LINE102

SEWER MANHOLE

PROPOSED BUILDING

PROPOSED SPOT GRADE81.61PROPOSED CLEAN OUT

LEGEND

PVI

SIT

E D

ES

IGN

PVI S

ite D

esig

n, L

LCC

ivil E

ngin

eerin

g - L

and

Ent

itlem

ents

Mas

ter P

lann

ing

- Pro

ject

Man

agem

ent

339-

206-

1030

JOB NO:

CHECKED:DRAWN:

FILE:

SCALE:

128

HERS

EY S

T, H

ING

HAM

, MA

020

43

142

HERS

EY S

T, H

ING

HAM

, MA

020

43JU

LIET

FUL

GO

NI

REV.

:SE

AL:

PRO

POSE

D H

OUS

E

SHEET NO:

ISSU

ED F

OR

PERM

IT

C100

PRO

POSE

D S

EWER

CO

NN

ECTIO

N

JULY

14,

202

0PR

OJE

CT:

CLIE

NT /

APPL

ICAN

T:

CONS

ULTA

NT:

TOP COURSEBINDER COURSE

GRAVEL BASE

1' DIA. 1'

6"D

IA.

1'4'

MIN

.

34" CRUSED STONE

MECHANICALLY COMPACTEDIN 6" LIFTS

6" SEWER SERVICE

ORDINARY FILL MATERIAL COMPACTEDIN 6" LIFTS TO ACHIEVE MIN. 90% MAX.

DRY DENSITY.NO STONES LARGER THAN 2" DIAMETER

SEE PAVEMENT SECTION,LANDSCAPING OR TRENCH PATCH

DETAIL AS APPROPRIATE

4 TYPICAL CLEAN OUT ASSEMBLYNOT TO SCALE

FLOW

4" PVC CLEANOUT RISER STACK

4" PVC 45° BENDSEE TYPICAL PIPE TRENCHDETAIL FOR BEDDING

6"x6"x4"WYE

7 PLAN VIEWSCALE: 1"=20'

20'0' 10' 40'

8 SEWER PROFILESCALE H: 1"=20', V:1"=2'

GENERAL NOTES:1. EXISTING CONDITIONS INFORMATION IS REPRODUCED FROM THE EXISTING CONDITIONS PLAN PREPARED BY

NANTASKET SURVEY & ENGINEERING, LLC DATED AUGUST 6, 2020.2. SCREENED IMAGES SHOW EXISTING CONDITIONS. WHERE EXISTING CONDITIONS LIE UNDER OR ARE IMPINGED UPON

BY PROPOSED BUILDINGS AND/OR SITE ELEMENTS, THE EXISTING CONDITION WILL BE REMOVED, ABANDONEDAND/OR CAPPED OR DEMOLISHED AS REQUIRED.

3. THE LOCATIONS OF UNDERGROUND UTILITIES SHOWN ARE BASED ON THE SURVEY REFERENCED ABOVE. PRIOR TO THESTART OF ANY EXCAVATION, THE CONTRACTOR SHALL NOTIFY DIGSAFE AND THE PROPER LOCAL AUTHORITIES ORRESPECTIVE UTILITY COMPANIES TO CONFIRM THE LOCATION OF ALL EXISTING UTILITIES. ANY DAMAGE DUE TOFAILURE OF THE CONTRACTOR TO CONTACT THE PROPER AUTHORITIES SHALL BE BORNE BY THE CONTRACTOR.

4. CONTRACTOR SHALL THOROUGHLY FAMILIARIZE THEMSELVES WITH ALL CONSTRUCTION DOCUMENTS,SPECIFICATIONS AND SITE CONDITIONS PRIOR TO BIDDING AND PRIOR TO CONSTRUCTION.

5. ANY DISCREPANCIES BETWEEN DRAWINGS, SPECIFICATIONS, AND SITE CONDITIONS SHALL BE REPORTED IMMEDIATELYTO THE OWNER'S REPRESENTATIVE FOR CLARIFICATION AND RESOLUTION PRIOR TO BIDDING OR CONSTRUCTION.

6. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING CONDITIONS TO REMAIN THAT ARE DUE TOCONTRACTOR OPERATIONS.

7. ALL ITEMS TO BE REMOVED THAT ARE NOT STOCKPILED FOR LATER REUSE ON THE PROJECT OR DELIVERED TO THEOWNER SHALL BE LEGALLY DISPOSED OF BY THE CONTRACTOR.

8. THE CONTRACTOR SHALL COORDINATE ALL ADJUSTMENT OR ABANDONMENT OF UTILITIES WITH THE RESPECTIVE UTILITYCOMPANY.

9. ELECTRIC AND GAS SERVICE ARE SHOWN FOR COORDINATION PURPOSES ONLY. CONTRACTOR SHALL CONTACTLOCAL UTILITY COMPANY TO COORDINATE FINAL CONNECTION POINTS.

SEWER NOTES:1. WHERE AN EXISTING UTILITY IS FOUND TO CONFLICT WITH THE PROPOSED WORK, THE LOCATION, ELEVATION, AND

SIZE OF THE UTILITY SHALL BE ACCURATELY DETERMINED WITHOUT DELAY BY THE CONTRACTOR, AND THEINFORMATION FURNISHED TO THE ENGINEER FOR RESOLUTION OF THE CONFLICT.

2. ALL WORK SHALL CONFORM TO THE TOWN OF HINGHAM SEWER RULES AND REGULATIONS AND SPECIFICATIONS.RULES AND REGULATIONS ARE AVAILABLE AT WWW.HINGHAM-MA.GOV

3. ALL SEWER PIPES SHALL BE PVC PER ASTM D3034, SDR-35 AND ASTM D1784 WITH RUBBER GASKET JOINTS.4. CONTRACTOR SHALL PROVIDE ALL FITTINGS, BENDS, RESTRAINTS, THRUST BLOCKS, AND OTHER APPURTENANCES

NECESSARY FOR INSTALLATION OF WATER SERVICE WHETHER SPECIFICALLY NOTED OR NOT.5. THE MINIMUM ALLOWABLE SLOPE SHALL BE 2.0%6. SURFACE WATER, GROUNDWATER FROM SUMP PUMPS, ROOF DOWNSPOUTS AND OTHER STORMWATER PIPED

SYSTEMS SHALL NOT BE DISCHARGED TO THE SEWER.7. THE SEWER SHALL BE INSTALLED BY A HINGHAM LICENSED DRAINLAYER.8. AN AS-BUILT DRAWING SHALL BE SUBMITTED TO THE TOWN OF HINGHAM WITHIN 10-DAYS OF INSTALLATION OF THE

SEWER SYSTEM AND PRIOR TO ANY FINAL APPROVAL. THE CONTRACTOR IS RESPONSIBLE FOR DOCUMENTING ANYVARIATION TO THE DESIGN AND PROVIDE INFORMAITON TO THE ENGINEER OF RECORD.

TRACER TAPEGREEN, 3" WIDE (MIN)

LABELED "BURIED SEWERLINE BELOW"

12"±

6" LOAM

PROVIDE DETECTABLE,THREADED CAP BURIED 6"

(MAX) BELOW FINISH GRADE

INSPECTION REQUIREMENTS:1. NOTIFY THE TOWN OF HINGHAM BOARD OF SEWER COMMISSIONERS THREE (3) BUSINESS DAYS PRIOR TO

INSTALLATION OF THE SEWER SERVICE.2. IF A DESIGN CERTIFICATION IS REQUIRED, THE ENGINEER OF RECORD SHALL BE NOTIFIED (3) BUSINESS DAYS PRIOR

TO INSTALLATION OF THE SEWER SERVICE.3. ALL INSPECTIONS SHALL BE PERFORMED PRIOR TO BACK-FILL.

318"

C BA

COMPACTEDSUBGRADE

COMPACTED GRAVEL BASE

BINDER COURSE

SURFACE COURSE

BIT. CONCRETE WALKBIT. CONCRETE ROAD

A B C6" 1 1/2" 1"12" 2" 1"

5 ASPHALT PAVEMENTNOT TO SCALE

3 TYPICAL PIPE TRENCH NOT TO SCALE

1: 0

8-31

-202

0 S

EW. C

OM

MIS

SIO

N CO

MM

ENTS

DRAINAGE NOTES:1. DETENTION SYSTEM CHAMBERS MAYBE RE-CONFIGURED TO AVOID SITE CONSTRAINTS. TOTAL NUMBER OF

CHAMBERS SHALL MATCH IF CONFIGURATION IS CHANGED.2. IF GUTTERS AND DOWNSPOUTS ARE UTILIZED, THE 6" COLLECTION PIPE SHALL BE SOLID WALL PIPE. IF CRUSHED

STONE DRIP STRIPS ARE UTILIZED, 6" COLLECTION PIPE SHALL BE PERFORATED PIPE WRAPPED IN FILTER FABRIC FORTHE LENGTH OF THE DRIP-STRIP TO INTERCEPT RUNOFF WITH A CLEAN OUT AT THE UPSTREAM END.

3. ALL CLEAN OUT COVERS IN LANDSCAPED AREAS SHALL BE SET 6" BELOW FINISH GRADE AND AS-BUILT LOCATIONSPROVIDED TO THE ENGINEER FOR RECORD.

4. CONTRACTOR SHALL PROVIDE AS-BUILT SWING TIE INFORMATION FOR DETENTION SYSTEMS TO THE OWNER ANDOWNER'S ENGINEER FOR RECORD PURPOSES.

WEED INHIBITING FABRIC

BUILDING FACE

34" TO 1-1/2" DIA. WASHED DRAINAGE

AGGREGATE. TAMP TO DEPTH OF 5" (MIN.).

VARIES,ADJUST TOMEET ROOFOVERHANG

24"MIN36" TYPICAL

6" DIA. PERFORATED PVC PIPE, WRAPWITH FILTER FABRIC, CONNECT TONEAREST DRAINAGE SYSTEM, TYP.SEE PLAN FOR LOCATIONS

3"

3/4" WASHED DECORATIVE RIVER STONE

COMPACTED ORDINARY BACKFILL

12" M

IN

6 RIVERSTONE DRIP STRIPNOT TO SCALE

67.5067.00

69.00

SYSTEM ELEVATIONSCHAMBER NOTES:1. CHAMBERS SHALL BE STORMTECH CHAMBER

SC-160LP OR EQUAL.2. CHAMBERS SHALL CONFORM TO THE

REQUIREMENTS OF ASTM F2418 "STANDARDSPECIFICATION FOR POLYPROPYLENE (PP)CORRUGATED WALL STORMWATERCOLLECTION CHAMBERS", OR ASTM F2922"STANDARD SPECIFICATION FORPOLYETHYLENE (PE) CORRUGATED WALLSTORMWATER COLLECTION CHAMBERS"

3. CHAMBERS SHALL BE DESIGNED INACCORDANCE WITH ASTM F2787 "STANDARDPRACTICE FOR STRUCTURAL DESIGN OFTHERMOPLASTIC CORRUGATED WALLSTORMWATER COLLECTION CHAMBERS".

*TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVEDINSTALLATIONS WHERE RUTTING FROM VEHICLES MAY

OCCUR, INCREASE COVER TO 20" (510 mm).

PAVEMENT LAYER SEETYPICAL DETAIL

SUBGRADE SOILS

PERIMETER STONE(SEE NOTE 4)

EXCAVATION WALL(CAN BE SLOPED OR VERTICAL)

SC-160LPEND CAP NO SPACING REQUIRED

BETWEEN CHAMBERS

12"

14"MIN*

10'MAX

6" MIN

12" MIN 25" 12" TYP6" BASE STONE

ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALLAROUND CLEAN, CRUSHED, ANGULAR STONE

#1

66.5066.00

68.00

#2

1 TYPICAL UNDERGROUND CHAMBER SYSTEMNOT TO SCALE

6" HEADER INV: 66.004" OUTLET INV: 67.00

4" OUTLET INV: 67.17

HIGH OUTLET PIPE FROMADJACENT CHAMBERSSYSTEM 2

OUTLET ELEVATIONS

8" HEADER INV: 67.503" OUTLET INV: 68.00

TWO (2) 3" OUTLETS INV: 68.25

SYSTEM 1

2 CHAMBER OUTLET DETAILNOT TO SCALE

2: 0

4-12

-202

1 IS

SUED

FO

R SI

TE P

LAN

APPR

OVA

L

AS-BUILT NOTE:CONTRACTOR SHALL PREPARE, OR COORDINATE WITHTHE LAND SURVEYOR OR ENGINEER TO PREPARE, ANAS-BUILT PLAN OF ALL PROPOSED SITE IMPROVEMENTSAND UNDERGROUND UTILITIES. THE PLAN SHALLINCLUDE SWING TIES TO UNDERGROUND DETENTIONSYSTEMS. AS-BUILT PLAN MUST BE SUBMITTED TO THETOWN PRIOR TO ISSUANCE OF A CERTIFICATE OFOCCUPANCY.

BUILDING GSF HOUSE: BARN: 1,772

3,200

LOT AREA: 37,680 SF20,000 SF

SETBACKS: FRONT: SIDE: REAR:

25'15'15'

45.1'16.8'15.7'

FRONTAGE: 125' 179.78'

PROPOSEDREQUIRED

ZONING TABLE - RESIDENCE A

3: 0

5-18

-202

1 P

EER

REVI

EW C

OM

MEN

TS

4: 0

5-19

-202

1 S

OIL

TES

TING

SOIL LOGSDEPTH HORIZ SOIL TYPE

TP-1 EG: 70.612" A LOAM18" B SANDY LOAM68" C FINE SANDREFUSAL: 64.93

TP-2 EG: 70.046" - FILL42" A LOAM69" C FINE SANDREFUSAL: 64.25

TP-13 EG: 68.012" A LOAM24" B SANDY LOAM48" C FINE SANDREFUSAL: 64.00

AutoCAD SHX Text
55
AutoCAD SHX Text
56
AutoCAD SHX Text
57
AutoCAD SHX Text
58
AutoCAD SHX Text
59
AutoCAD SHX Text
60
AutoCAD SHX Text
61
AutoCAD SHX Text
62
AutoCAD SHX Text
63
AutoCAD SHX Text
64
AutoCAD SHX Text
65
AutoCAD SHX Text
66
AutoCAD SHX Text
66
AutoCAD SHX Text
67
AutoCAD SHX Text
67
AutoCAD SHX Text
68
AutoCAD SHX Text
68
AutoCAD SHX Text
69
AutoCAD SHX Text
69
AutoCAD SHX Text
69
AutoCAD SHX Text
69
AutoCAD SHX Text
69
AutoCAD SHX Text
70
AutoCAD SHX Text
70
AutoCAD SHX Text
70
AutoCAD SHX Text
70
AutoCAD SHX Text
70
AutoCAD SHX Text
71
AutoCAD SHX Text
71
AutoCAD SHX Text
71
AutoCAD SHX Text
71
AutoCAD SHX Text
72
AutoCAD SHX Text
Paved Driveway
AutoCAD SHX Text
Paved Driveway
AutoCAD SHX Text
Hedge Row
AutoCAD SHX Text
#122 2-Story House
AutoCAD SHX Text
Porch
AutoCAD SHX Text
Garage
AutoCAD SHX Text
Shed
AutoCAD SHX Text
Stone Wall
AutoCAD SHX Text
Stone Wall
AutoCAD SHX Text
FFE=71.3' x
AutoCAD SHX Text
Shed
AutoCAD SHX Text
x70.0'
AutoCAD SHX Text
x70.3'
AutoCAD SHX Text
78x3
AutoCAD SHX Text
74x5
AutoCAD SHX Text
75x4
AutoCAD SHX Text
71x9
AutoCAD SHX Text
Ledge
AutoCAD SHX Text
75x7
AutoCAD SHX Text
75x6
AutoCAD SHX Text
74x9
AutoCAD SHX Text
75x5
AutoCAD SHX Text
75x2
AutoCAD SHX Text
Ledge
AutoCAD SHX Text
73x4
AutoCAD SHX Text
72x9
AutoCAD SHX Text
73x1
AutoCAD SHX Text
Ledge
AutoCAD SHX Text
73x2
AutoCAD SHX Text
73x2
AutoCAD SHX Text
72x0
AutoCAD SHX Text
Ledge
AutoCAD SHX Text
71x5
AutoCAD SHX Text
Ledge
AutoCAD SHX Text
EOP
AutoCAD SHX Text
EOP
AutoCAD SHX Text
69x4
AutoCAD SHX Text
69x6
AutoCAD SHX Text
69.5x
AutoCAD SHX Text
69x5
AutoCAD SHX Text
69x7
AutoCAD SHX Text
69x2
AutoCAD SHX Text
69x5
AutoCAD SHX Text
69.9x
AutoCAD SHX Text
69x5
AutoCAD SHX Text
69x7
AutoCAD SHX Text
70x5
AutoCAD SHX Text
70x8
AutoCAD SHX Text
70x5
AutoCAD SHX Text
70x7
AutoCAD SHX Text
70x6
AutoCAD SHX Text
70x4
AutoCAD SHX Text
70x8
AutoCAD SHX Text
69x4
AutoCAD SHX Text
55x2
AutoCAD SHX Text
54x1
AutoCAD SHX Text
x68.5
AutoCAD SHX Text
70x5
AutoCAD SHX Text
68.4x
AutoCAD SHX Text
70x3
AutoCAD SHX Text
70x3
AutoCAD SHX Text
68x7
AutoCAD SHX Text
Wood Posts
AutoCAD SHX Text
67x6
AutoCAD SHX Text
69x7
AutoCAD SHX Text
68x5
AutoCAD SHX Text
69x3
AutoCAD SHX Text
65x4
AutoCAD SHX Text
x 67.6
AutoCAD SHX Text
x 68.0
AutoCAD SHX Text
x 68.5
AutoCAD SHX Text
x 68.8
AutoCAD SHX Text
x 69.2
AutoCAD SHX Text
x 69.5
AutoCAD SHX Text
x 70.5
AutoCAD SHX Text
x 70.4
AutoCAD SHX Text
x 69.9
AutoCAD SHX Text
Wood Fence
AutoCAD SHX Text
PVC Fence
AutoCAD SHX Text
Flag Stones
AutoCAD SHX Text
Well
AutoCAD SHX Text
Fire Pit
AutoCAD SHX Text
Pavers
AutoCAD SHX Text
Brick Walk
AutoCAD SHX Text
S
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
Paved Sidewalk
AutoCAD SHX Text
WG
AutoCAD SHX Text
H
AutoCAD SHX Text
Y
AutoCAD SHX Text
D
AutoCAD SHX Text
Dec. Tree on Lot Cor.
AutoCAD SHX Text
RIM=67.76'
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
CO
AutoCAD SHX Text
97
AutoCAD SHX Text
019-007
AutoCAD SHX Text
TJP
AutoCAD SHX Text
1"=20'
AutoCAD SHX Text
019-007-BASE.dwg
AutoCAD SHX Text
TJP
AutoCAD SHX Text
FINISH GRADE