HOTWIREt MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH EIA 530a INTERFACE USER’S GUIDE Document No. 7985-A2-GB20-00 October 1998

Transcript of HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH...

Page 1: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

HOTWIRE� MODEL 7985M/HDSL STANDALONE

TERMINATION UNITWITH EIA 530a INTERFACE

USER’S GUIDEDocument No. 7985-A2-GB20-00

October 1998

Page 2: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Printed on recycled paper

A 7985-A2-GB20-00October 1998

Copyright � 1998 Paradyne Corporation.All rights reserved.Printed in U.S.A.

Notice

This publication is protected by federal copyright law. No part of this publication may be copied or distributed,transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any formor by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without theexpress written permission of Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773.

Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specificallydisclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporationreserves the right to revise this publication and to make changes from time to time in the contents hereof withoutobligation of Paradyne Corporation to notify any person of such revision or changes.

Changes and enhancements to the product and to the information herein will be documented and issued as a newrelease to this manual.

Warranty, Sales, and Service Information

Contact your local sales representative, service representative, or distributor directly for any help needed. Foradditional information concerning warranty, sales, service, repair, installation, documentation, training, distributorlocations, or Paradyne worldwide office locations, use one of the following methods:

� Via the Internet: Visit the Paradyne World Wide Web site at http://www.paradyne.com

� Via Telephone: Call our automated call system to receive current information via fax or to speak with a company representative.

— Within the U.S.A., call 1-800-870-2221— Outside the U.S.A., call 1-727-530-2340

Trademarks

All products and services mentioned herein are the trademarks, service marks, registered trademarks or registeredservice marks of their respective owners.

Document Feedback

We welcome your comments and suggestions about this document. Please mail them to Technical Publications,Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to [email protected]. Includethe number and title of this document in your correspondence. Please include your name and phone number if youare willing to provide additional clarification.

Page 3: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Important Information

B7985-A2-GB20-00 October 1998

Important Safety Instructions

1. Read and follow all warning notices and instructions marked on the product or included in the manual.

2. Input power to this product must be provided by one of the following: (1) a UL Listed/CSA Certified power sourcewith a Class 2 or Limited Power Source (LPS) output for use in North America; or (2) a 24 Vdc National ElectricCode (NEC) ANSI/NFPA 70/Canadian Electric Code (CEC) Class 2 circuit installed in accordance with articles110-16, 110-17, and 110-18 of the NEC, and articles 2-308, 2-310, 2-312, 2-314, 2-200, and 2-202 of the CEC, or(3) a Safety Extra Low Voltage (SELV) power source with a maximum available output of less than 240 VA,certified for use in the country of installation.

3. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and toprotect it from overheating, these slots and openings must not be blocked or covered.

4. Do not allow anything to rest on the power cord and do not locate the product where persons will walk on thepower cord.

5. Do not attempt to install or service this product yourself, as opening or removing covers may expose you todangerous high voltage points or other risks. Refer all installation and servicing to qualified service personnel.

6. General purpose cables are provided with this product. Special cables, which may be required by the regulatoryinspection authority for the installation site, are the responsibility of the customer.

7. When installed in the final configuration, the product must comply with the applicable Safety Standards andregulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatoryagencies and inspection authorities to ensure compliance.

8. A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. Ifproducts installed in separate buildings are interconnected , the voltage potential may cause a hazardouscondition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, ifnecessary, implement corrective action prior to interconnecting the products.

9. In addition, if the equipment is to be used with telecommunications circuits, take the following precautions:

— Never install telephone wiring during a lightning storm.

— Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

— Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at thenetwork interface.

— Use caution when installing or modifying telephone lines.

— Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk ofelectric shock from lightning.

— Do not use the telephone to report a gas leak in the vicinity of the leak.

Page 4: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Important Information

C 7985-A2-GB20-00October 1998

EMI Warnings

! WARNING:This equipment has been tested and found to comply with the limits for a Class A digital device,pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection againstharmful interference when the equipment is operated in a commercial environment. This equipmentgenerates, uses, and can radiate radio frequency energy and, if not installed and used in accordancewith the instruction manual, may cause harmful interference to radio communications. Operation of thisequipment in a residential area is likely to cause harmful interference in which case the user will berequired to correct the interference at his own expense.

The authority to operate this equipment is conditioned by the requirements that no modifications will bemade to the equipment unless the changes or modifications are expressly approved by ParadyneCorporation.

! WARNING:To Users of Digital Apparatus in Canada:

This Class A digital apparatus meets all requirements of the Canadian interference-causing equipmentregulations.

Cet appareil numérique de la classe A respecte toutes les exigences du règlement sur le matérialbrouilleur du Canada.

Page 5: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

i7985-A2-GB20-00 October 1998

Contents

About This Guide� Document Purpose and Intended Audience iv. . . . . . . . . . . . . . . . . . . . . . . . .

� Document Summary iv. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Product-Related Documents v. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 About the Model 7985 Standalone Termination Unit� M/HDSL Overview 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Model 7985 Features 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Network Configuration 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� User Interface Types 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Front Panel LED Status Indicators 1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Rear Panel Interface Connections 1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� MIB Support 1-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2 Using the Asynchronous Terminal Interface� User Interface Access 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Communication Port Settings 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Initiating an ATI Session 2-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Screen Work Areas 2-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Navigating the Screens 2-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Keyboard Keys 2-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Screen Function Keys 2-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Switching Between Screen Work Areas 2-8. . . . . . . . . . . . . . . . . . . . . . . .

� Ending an ATI Session 2-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3 Initial Startup and Configuration� Overview 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Connecting Power to the Unit 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Connecting the Unit to an Optional External DC Power Source 3-2. . . .

� Connecting to the Network 3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Connecting to a System Terminal 3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Entering Identity Information 3-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 6: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Contents

ii 7985-A2-GB20-00October 1998

� Choosing a Configuration Mode 3-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Configuring the Unit Using the Configuration Menus 3-5. . . . . . . . . . . . . . . . .

Configuration Options 3-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Configuring the Unit Using the Internal Switches 3-6. . . . . . . . . . . . . . . . . . . .

Switchpack Locations 3-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Switchpack Definitions 3-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Accessing and Displaying Configuration Options 3-11. . . . . . . . . . . . . . . . . . . .

� Configuration Edit/Display 3-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Configuring AutoRate 3-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Configuration Loader 3-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Saving Configuration Options 3-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Download Code 3-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 Monitoring the Unit� What to Monitor 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Viewing System and Test Status 4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Health and Status 4-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Self-Test Results 4-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Test Status 4-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Viewing Network Error Statistics 4-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Viewing Network Performance Statistics 4-8. . . . . . . . . . . . . . . . . . . . . . . . . . .

� Viewing Model 7985 Standalone Termination Unit LEDs 4-9. . . . . . . . . . . . . .

� Model 7985 Standalone Termination Unit LEDs 4-10. . . . . . . . . . . . . . . . . . . . .

5 Testing� Accessing the Test Menu 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Running Network Tests 5-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Line Loopback 5-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Repeater Loopback 5-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Send Remote Line Loopback 5-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Send and Monitor 511 5-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Running SYNC Data Port Tests 5-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Data Terminal Loopback 5-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Data Channel Loopback 5-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Send Remote Data Channel Loopback 5-10. . . . . . . . . . . . . . . . . . . . . . . . .

� Device Tests 5-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Lamp Test 5-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Ending an Active Test 5-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 7: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Contents

iii7985-A2-GB20-00 October 1998

6 Messages and Troubleshooting� Overview 6-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Configuring SNMP Traps 6-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Device Messages 6-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Troubleshooting 6-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7 Security� Overview 7-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� ATI Access Levels 7-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Creating a Login 7-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Deleting a Login 7-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Resetting the Termination Unit’s COM Port or Factory Defaults 7-4. . . .

8 IP Addressing� Selecting an IP Addressing Scheme 8-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� IP Addressing Example 8-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A Configuration Option Tables� Overview A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Network Interface Options Menu A-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Synchronous Data Port Options Menu A-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� System Options Menu A-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Communication Port A-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Management and Communication Options Menu A-11. . . . . . . . . . . . . . . . . . . .

� Telnet Session Options A-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Communication Protocol Options A-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SNMP Traps Options A-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

B Standards Compliance for SNMP Traps� SNMP Traps B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

warmStart B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

authenticationFailure B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

linkUp and linkDown B-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Enterprise-Specific Traps B-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 8: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Contents

iv 7985-A2-GB20-00October 1998

C Cables and Pin Assignments� Overview C-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� DSL Network Interface Cable C-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� COM Port Interface Cable C-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� EIA-530A Port Interface Connector C-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� EIA-530A-to-X.21 Interface Cable C-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� EIA-530A-to-RS449 Cable Interface C-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� EIA-530A-to-V.35 Cable Interface C-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Power Input Connector C-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

� Optional Power Cable C-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

D Technical Specifications

Glossary

Index

Page 9: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

v7985-A2-GB20-00 October 1998

About This Guide

Document Purpose and Intended Audience

This guide contains information needed to set up, configure, and operate theHotwire Model 7985 Multirate/High-bit-rate Digital Subscriber Line (M/HDSL)Standalone Termination Unit and is intended for installers and operators.

Document Summary

Section Description

Chapter 1 About the Model 7985 Standalone Termination Unit.Describes the Model 7985 Termination Unit’s features andcapabilities.

Chapter 2 Using the Asynchronous Terminal Interface. Providesinstructions for accessing the user interface and navigatingthrough the screens.

Chapter 3 Initial Startup and Configuration. Provides procedures forsetting up the user interface and configuration steps.

Chapter 4 Monitoring the Unit. Describes using the LEDs, status, andnetwork statistics to monitor the unit.

Chapter 5 Testing. Provides information about available tests and testsetup.

Chapter 6 Messages and Troubleshooting. Provides information onSNMP traps, device messages, and troubleshooting.

Chapter 7 Security. Presents procedures for creating a login, settingthe effective access levels, and controlling SNMP access.

Chapter 8 IP Addressing. Provides information and examplesregarding IP addresses.

Page 10: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

About This Guide

vi 7985-A2-GB20-00October 1998

Section Description

Appendix A Configuration Option Tables. Contains all configurationoptions, default settings, and possible settings.

Appendix B Standards Compliance for SNMP Traps. Contains SNMPtrap compliance information.

Appendix C Cables and Pin Assignments. Contains connector andinterface information.

Appendix D Technical Specifications. Contains physical and regulatoryspecifications, network and port interfaces, powerconsumption values, and accessory part numbers.

Glossary Defines acronyms and terms used in this document.

Index Lists key terms, acronyms, concepts, and sections inalphabetical order.

Product-Related Documents

Document Number Document Title

8784-A2-GB20 Hotwire 8784 M/HDSL Termination Unit with DSX-1Interface User’s Guide

8786-A2-GB20 Hotwire 8786 M/HDSL Termination Unit with G.703Interface User’s Guide

8786-A2-GZ40 Hotwire 8786 M/HDSL Termination Unit InstallationInstructions

Contact your sales or service representative to order additional productdocumentation.

Paradyne documents are also available on the World Wide Web at:

http://www.paradyne.com

Select Service & Support → Technical Manuals

Page 11: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

1-17985-A2-GB20-00 October 1998

About the Model 7985 StandaloneTermination Unit

1M/HDSL Overview

Hotwire� Multirate/High-bit-rate Digital Subscriber Line (M/HDSL) productsmaximize customer service areas by varying the DSL line rate. This ensuressymmetric DSL connectivity over a wide range of telephone line distances andtransmission line qualities.

Hotwire M/HDSL products can transport at full or fractional payload rates over a4-wire, full-duplex circuit over varying distances based on the conditions of the4-wire loop. Examples include support for router, multiplexer and PBXconnections at 128 kbps, with distances exceeding 29,000 feet (8.9 km) on 24 gauge (.5 mm) cable, or up to 15,000 feet (4.6 km) delivered at 2.048 Mbps on24 gauge (.5 mm) cable.

Hotwire M/HDSL is equipped with an automatic configuration capability thatreduces the M/HDSL installation process to a simple plug and play mode. Simplyconnecting the units to the line automatically configures the customer for themaximum data rate supported by the local loop. M/HDSL units can also beconfigured at fixed line speeds to achieve maximum distances.

Page 12: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

About the Model 7985 Standalone Termination Unit

1-2 7985-A2-GB20-00October 1998

Model 7985 Features

The Hotwire Model 7985 M/HDSL Standalone Termination Unit is an endpoint forthe chassis-mounted Hotwire Model 8784 or 8786 M/HDSL Termination Unithoused in the Hotwire 8600 or 8800 Digital Subscriber Line Access Multiplexer(DSLAM).

Two Hotwire Model 7985 M/HDSL Standalone Termination Units can also beconfigured to operate in a central office (CO) to customer premises (CP)environment.

The Model 7985 Standalone Termination Unit offers these standard features:

� AutoRate Capability. Provides automatic configuration of line speed anddata rate upon connection.

� Embedded Operations Channel (EOC). Provides remote SNMP Traps orTelnet session capability over the M/HDSL network.

� Asynchronous Terminal Interface (ATI). Provides a menu-drivenVT100-compatible terminal interface for configuring and managing thetermination unit locally or remotely by Telnet session.

� Local Management. Provides local management using a:

— Terminal or PC via the COM port of the unit

� Remote Management. Provides remote management using:

— Terminal or PC via the Management Serial port of the DSLAM

— Network Management System (NMS) via the COM port or MCC port ofthe DSLAM

— Telnet over the EOC

— External modem out-of-band

� Alarm Indication. Provides front panel status LEDs.

� Diagnostic Testing. Provides the capability to diagnose device and networkproblems and perform tests, including digital loopbacks, pattern tests, andself-test.

� Device and Performance Monitoring. Provides the capability of trackingand evaluating the unit’s operation, including health and status, and error-ratemonitoring.

Page 13: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

About the Model 7985 Standalone Termination Unit

1-37985-A2-GB20-00 October 1998

Network Configuration

Figure 1-1 shows a network application using a 2-port Hotwire 8786 or 8784M/HDSL Termination Unit for access concentration in a central office (CO). Aframe relay switch and a router are connected, through the termination unit, topartner units supporting a host or router, and frame relay encapsulated orunframed data.

FrameRelaySwitch

Router

E1 Host(Frame RelayEncapsulated

Data)

98-16131

Router(Frame RelayEncapsulated

Data)

EIA 530aV.35

Router2.048 Mb

overSDSL

8786 or 8784Termination Unitin 8600 DSLAM

CO Site7985

7985

7985

CustomerPremises (CP)

7985

CustomerPremises

NTUCO Site

LTU7985 (V.35)

7986 (G.703)7984 (DSX)

V.35

EIA 530aV.35

EIA 530aV.35

Figure 1-1. Sample M/HDSL Configurations

User Interface Types

There are three types of user interfaces to the Model 7985 StandaloneTermination Unit:

� Menu-driven async terminal interface screens. See Chapter 2, Using theAsynchronous Terminal Interface.

� Front panel LED status indicators. See Chapter 4, Monitoring the Unit.

� Internal DIP Switches. See Chapter 3, Initial Startup and Configuration.

Page 14: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

About the Model 7985 Standalone Termination Unit

1-4 7985-A2-GB20-00October 1998

Front Panel LED Status Indicators

Figure 1-2 shows the front panel of the Model 7985 Standalone Termination Unit.For more information on front panel LEDs, refer to Chapter 4, Monitoring the Unit.

POWER

ALARM

TESTDSL

DTE

98-16132

7985 M/HDSL

TM

TM

Figure 1-2. Hotwire Model 7985 Standalone Termination Unit Front Panel

Rear Panel Interface Connections

Figure 1-3 shows the physical interfaces of the Model 7985 StandaloneTermination Unit.

POWER DSLCOM

98-15880

PORT

O

I

Figure 1-3. Hotwire Model 7985 Standalone Termination Unit Rear Panel

Page 15: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

About the Model 7985 Standalone Termination Unit

1-57985-A2-GB20-00 October 1998

MIB Support

The Model 7985 Standalone Termination Unit supports traps as defined in RFC 1215. They may include variable-bindings specified in the following MIBs:

� MIB II (RFC 1573) – Defines the general objects for use with a networkmanagement protocol in TCP/IP internets and provides general informationabout the Model 7985 Standalone Termination Unit. MIB II isbackward-compatible with MIB I.

� Enterprise MIB – Supports configuration, status, statistics, and tests.

Figure 1-4 illustrates a typical M/HDSL SNMP configuration. Refer to Chapter 8,IP Addressing and Appendix B, Standards Compliance for SNMP Traps.

98-16134

V.35

8600DSLAM

Network

7985

AC

INPUTAC

48VDC CLASS 2 ORLIMITED PWR SOURCE

RTN48V

AA B B

T5A

2

4 6

A B

.

..3

.12

POSITIONSTACK

ALM A

IN

B

DC FUSEST4A, MIN. 48V

5DC PWRFAN

OUT SERIAL MCC 1 3

1

2

3SYSTEM

OK Alrm Test

TX RX Col 1 2 3 4

ETHERNET

DSL PORT

RA

DS

L

8546

250VSYSTEM

OK Alrm Test

1 2 3 4

G.703

ALR

M

DSL PORT

LI

NK-UP

SD

SL

87151 2 3 4

SYSTEMOK Alrm Te

st1 2 3 4

G.703

ALR

M

DSL PORT

LI

NK-UP

SD

SL

87151 2 3 4Router

SNMP NMS8786 or 8784

EthernetInterface

DSL

EOC

Data

Voice

Operation, Maintenanceand Provisioning Center

EthernetLAN

Figure 1-4. M/HDSL SNMP Configuration

Page 16: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

About the Model 7985 Standalone Termination Unit

1-6 7985-A2-GB20-00October 1998

This page intentionally left blank.

Page 17: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

2-17985-A2-GB20-00 October 1998

Using the Asynchronous TerminalInterface

2User Interface Access

You can communicate with the Hotwire Model 7985 Standalone Termination Unitwith an asynchronous terminal interface (ATI) using one of the following methods:

� Direct connection through the COM port.

� Using an external modem through the COM port.

� Telnet session through the Embedded Operations Channel (EOC).

NOTE:Only one asynchronous terminal interface session can be active at a time,and another user’s session cannot be forced to end. To automatically log outa user due to inactivity, enable the Inactivity Timeout option (see Table A-5,Telnet Session Options, in Appendix A, Configuration Option Tables).

Security can limit ATI access several ways. To limit user access or set up loginIDs, refer to Chapter 7, Security.

Communication Port Settings

Ensure that the device you connect communicates using these settings:

� Data rate set to 9.6 kbps.

� Character length set to 8.

� Parity set to None.

� Stop Bits set to 1.

Page 18: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Using the Asynchronous Terminal Interface

2-2 7985-A2-GB20-00October 1998

Initiating an ATI SessionThe Main Menu screen is displayed on the screen unless a login ID andpassword is required or the ATI is already in use.

If security is enabled on the Model 7985 Standalone Termination Unit and youused Telnet to access it directly (you did not log in through the MCC), the systemprompts you for a login ID and password.

ÎÎ

ÎÎÎÎ

Login Hotwire Model: 7985

LOGIN

Login ID: Enter Password:

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions E xit

After you enter a valid login ID and password, the Main Menu appears. If youenter an invalid login ID and password after three attempts, the Telnet sessioncloses or the terminal connection returns to an idle state. Refer to Chapter 7,Security.

If the ATI is already in use, you will see a connection refused orconnection failed message (if you are using a Telnet session), or you willsee the IP address of the other user (if you are using the Management Serialport).

Page 19: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Using the Asynchronous Terminal Interface

2-37985-A2-GB20-00 October 1998

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

main Access Level: Administrator Hotwire Model 7985

MAIN MENU

StatusTestConfigurationControl

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions E xit

ScreenArea

ScreenFunctionKeysArea

Entry to all of the termination unit’s tasks begins at the Main Menu screen. Thefour branches of the Main menu are as follows:

Select . . . To . . .

Status View system status, diagnostic test results, statistics, LEDs, and deviceidentity information.

Test Select and cancel tests for the termination unit’s interfaces.

Configuration Display and edit the configuration options.

Control Change the device identity, administer logins, download new firmware, orinitiate a power-up reset of the termination unit.

After selecting an option, what appears on the screens depends on the:

� Current configuration – How your termination unit is currently configured.

� Effective security access level – An access level that is typically set by thesystem administrator for each interface and each user.

� Data selection criteria – What you entered in previous screens.

Page 20: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Using the Asynchronous Terminal Interface

2-4 7985-A2-GB20-00October 1998

The following illustration shows the paths to the different ATI screens.

Main

Status Test

System andTest Status

PerformanceStatistics

DisplayLEDs

Identity

NetworkError

Statistics

NetworkPerformance

Statistics

Configuration Control

FactoryConfig

ConfigurationLoader

Current ConfigurationEdit/Display

SystemOptions

CommunicationProtocol Option

CommunicationPort

Managementand

Communication

TelnetSession

SNMPTraps

ChangeIdentity

AdministerLogins

DownloadCode

ApplyDownload

ResetAutoRate

Network Tests SYNC DataPort Tests

DeviceTests

AbortAll

Tests

98-15859

ResetDevice

Network SyncPort

Page 21: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Using the Asynchronous Terminal Interface

2-57985-A2-GB20-00 October 1998

Screen Work Areas

There are two user work areas:

� Screen area – This is the area above the dotted line that provides the menupath, menus, and input fields.

The menu path appears as the first line on the screen. In this manual, themenu path is presented as a menu selection sequence with the names of thescreens:

Main Menu →Configuration → Load Configuration From →NetworkInterface Options

� Screen function key area – This is the area below the dotted line that listsfunction keys specific to the screen, field value choices, and systemmessages.

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

main/config/network Hotwire Model: 7985

NETWORK INTERFACE OPTIONS

Margin Threshold: –3dbExcessive Error Rate Threshold: 1E–5AutoRate: Enable

Peer IP Address: 111 .255 .255 .000 Clear

Circuit Identifier: Clear

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit S aveSelect: 1E–4, 1E–5, 1E–6, 1E–7, 1E–8, 1E–9 LOS at Net, Pt n

Menu Path

ScreenFunction

Keys

Field ValueChoices

SystemMessages

Input Fields

Page 22: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Using the Asynchronous Terminal Interface

2-6 7985-A2-GB20-00October 1998

Navigating the Screens

You can navigate the screens by:

� Using keyboard keys

� Using screen function keys

� Switching between the two screen work areas

Keyboard Keys

Use the following keyboard keys to navigate within the screen.

Press . . . To . . .

Ctrl-a Move cursor between the screen area and the screen functionkeys area below the dotted line at the bottom of the screen.

Esc Return to the previous screen.

Tab Move cursor to the next field on the screen.

Backspace Move cursor to the previous field on the screen.

Return (Enter) Accept entry or display valid options on the last row of the screenwhen pressed before entering data or after entering invalid data.

Ctrl-k Tab backwards (move cursor one field to the left).

Spacebar Select the next valid value for the field.

Delete (Del) Delete character that the cursor is on.

Up Arrow or Ctrl-u Move cursor up one field within a column on the same screen.

Down Arrow or Ctrl-d Move cursor down one field within a column on the same screen.

Right Arrow or Ctrl-f Move cursor one character to the right if in edit mode.

Left Arrow or Ctrl-b Move cursor one character to the left if in edit mode.

Ctrl-l Redraw the screen display, clearing information typed in but notyet entered.

� Procedure

To make a menu or field selection:

1. Press the Tab key or the right arrow key to position the cursor on a menu orfield selection. Each selection is highlighted as you press the key to move thecursor from position to position.

2. Press Enter.

The selected menu or screen appears.

3. Continue Steps 1 and 2 until you reach the screen you want.

Page 23: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Using the Asynchronous Terminal Interface

2-77985-A2-GB20-00 October 1998

The current setting or value appears to the right of the field name. You can enterinformation into a selected field by:

� Typing in the first letter(s) of a field value or command.

� Switching from the screen area to the screen function area below the dottedline and selecting or entering the designated screen function key.

If a field is blank and the Field Values screen area displays valid selections, pressthe spacebar and the first valid value for the field will appear. Continue pressingthe spacebar to scroll through other valid values.

Screen Function Keys

All screen function keys located below the dotted line operate the same way(upper- or lowercase) throughout the screens.

For the screenfunction . . . Select . . . And press Enter to . . .

ClrFar F or f Clear far-end network statistics and refresh the screen.

ClrNear N or n Clear near-end network statistics and refresh the screen.

ClrStats S or s Clear G.703 statistics and refresh the screen.

Delete L or l Delete data.

Exit E or e Terminate the async terminal session.

MainMenu M or m Return to the Main Menu screen.

New N or n Enter new data.

PgDn D or d Display the next page, or group of entries.

PgUp U or u Display the previous page, or group of entries.

ResetMon R or r Reset an active Monitor 511 test counter to zero.

Save S or s Save information.

Page 24: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Using the Asynchronous Terminal Interface

2-8 7985-A2-GB20-00October 1998

Switching Between Screen Work Areas

Select Ctrl-a to switch between the two screen work areas to perform all screenfunctions.

� Procedure

To access the screen function area below the dotted line:

1. Press Ctrl-a to switch from the screen area to the screen function key areabelow the dotted line.

2. Select either the function’s designated (underlined) character or press theTab key until you reach the desired function key.

Example:To save the current screen, type s or S (Save).

3. Press Enter.

4. To return to the screen area above the dotted line, press Ctrl-a again.

ÎÎ

ÎÎÎÎ

main/config/network Hotwire Model: 7985

NETWORK INTERFACE OPTIONS

Margin Threshold: –3dbExcessive Error Rate Threshold: 1E–5AutoRate DisableDSL Line rate 144

Peer IP Address: 111 .255 .255 .000 Clear

Circuit Identifier: Clear

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions , ESC for previous menu M ainMenu E xit S ave

Page 25: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Using the Asynchronous Terminal Interface

2-97985-A2-GB20-00 October 1998

Ending an ATI Session

Use the Exit function key from any screen to terminate the session.

� Procedure

To end a session with the asynchronous terminal interface:

1. Press Ctrl-a to go to the screen function key area below the dotted line.

2. Save changes if required. A confirmation message appears if you have madebut not saved changes to your configuration.

3. Tab to Exit (or type e or E) and press Enter.

Page 26: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Using the Asynchronous Terminal Interface

2-10 7985-A2-GB20-00October 1998

This page intentionally left blank.

Page 27: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

3-17985-A2-GB20-00 October 1998

Initial Startup and Configuration

3Overview

This chapter provides instructions on how to access and configure your unit forthe first time. This chapter includes procedures for:

� Connecting power to the unit.

� Connecting the unit to the network.

� Connecting a system terminal.

� Providing initial unit identity information or changing existing identityinformation.

� Configuring your unit using internal switchpacks or using the ConfigurationEdit menus.

� Choosing the current or factory default configuration options or downloadingconfiguration options from a TFTP server.

� Modifying current configuration options using the Configuration Edit/Displaymenu.

� Saving your changes.

� Downloading unit firmware from a TFTP server.

Page 28: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-2 7985-A2-GB20-00October 1998

Connecting Power to the Unit

If your package includes a power pack: Plug the power pack into an ac outlethaving a nominal voltage rating between 100–240 Vac. Connect the output cableof the power pack to the connector marked POWER on the rear panel.

If your package includes a direct-connection dc power cable: Connect the unit toan external dc power source as described in Connecting the Unit to an OptionalExternal DC Power Source.

Connecting the Unit to an Optional External DC Power Source

Use the following procedures only if you want to use the dc power cable.

Using the dc power cable, the Hotwire Model 7985 Standalone Termination Unitis capable of operating on a +24 Vdc power supply.

� Procedure

To use the dc power cable:

1. Connect the green wire to a suitable earth ground.

2. Connect the orange wire to the +24 Vdc source.

3. Connect the white wire to the return.

4. Cut the black, red, and blue wires off at the outer insulation.

5. Plug the power connector into the Model 7985 Standalone Termination Unit.

1

2

3

4

5

6

X

X

Earth Ground

RTN

+24 Vdc

X

Black

Red

Green

White

Orange

Blue

98-14158-01

+24 Vdc Power Supply Pinouts

Page 29: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-37985-A2-GB20-00 October 1998

Connecting to the Network

� Procedure

To connect your unit to the network:

1. Connect one end of the network cable into the rear panel DSL jack. Connectthe other end to your DSL network interface.

NOTE:A cross over cable (pins 1, 2 to 4, 5) is required for connecting two Model 7986 Termination Units back-to-back.

Do not use a flat VF network cable as this may severely degrade theperformance of the termination unit. Use only Cat 5 twisted-pair networkcable.

Connecting to a System Terminal

An optional system maintenance terminal may be attached to your Hotwire Model 7985 Standalone Termination Unit through the modular jack on the rearpanel. You may have terminals attached to both endpoints. The system terminalmust be a VT100-compatible terminal or a PC running terminal emulationsoftware.

The system maintenance terminal allows you to view the status of the unit, andchange configuration options.

Connect the 9-pin end of the terminal cable into a COM port on your PC. Plug theother end into the modular jack on the rear panel. If your PC requires a 25-pinconnector to the COM port, see Appendix C, Cables and Pin Assignments, for thecorrect cable pinouts.

Make sure the communication parameters on your PC or terminal are set to:

� 9600 baud

� 8 bit characters

� no parity

� 1 stop bit

� no flow control

Press Enter from your terminal or PC to activate the Main Menu for the attachedunit. The system runs diagnostics and status checks. After a few moments, theMain Menu or Logon screen appears on your terminal.

Page 30: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-4 7985-A2-GB20-00October 1998

Entering Identity Information

After accessing your unit for the first time, use the Change Identity screen todetermine SNMP administrative system information that will be displayed on theIdentity screen of the Status branch. To access the Card Identity screen, followthis menu selection sequence:

Main Menu →Control →Change Identity

ÎÎ

ÎÎÎÎ

main/control/change_identity HotwireModel: 7985

IDENTITY

System Name: lllQJ98-001 ClearSystem Location: Bldg. A412, 2nd Floor, Left cabinet ClearSystem Contact: C. Parker 800-727-2396 pager 888-555-1212 Clear

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit S ave

Fields on the Card Identity screen are null until you enter values. The field valuesdisplay 40 characters with a maximum field length of 128 characters. If a fieldvalue is greater than 40 characters in length, use the left or right arrow keys toview the remaining text. Valid values are any printable ASCII character. ASCIIprintable characters include:

� Numeric 0–9

� Upper or lower case A–Z

� Space

� All ASCII symbols except the caret (^)

Select Clear to reset a field to a null value.

� Procedure

To enter Change Identity screen information:

1. Position the cursor in the System Name field. Enter a name unique in yournetwork to identify the SNMP managed node (or unit).

The maximum length of System Name is 128 characters.

2. Position the cursor in the System Location field. Enter the physical location ofthe unit.

The maximum length of System Location is 128 characters.

Page 31: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-57985-A2-GB20-00 October 1998

3. Position the cursor in the System Contact field. Enter the name and contactinformation for the person responsible for the unit.

The maximum length of System Contact is 128 characters.

4. Press Ctrl-a to switch to the screen function key area below the dotted line.

5. Select Save and press Enter.

Choosing a Configuration ModeYou can make configuration changes either through a VT100 and the unit’sConfiguration menus or by manually changing switches on the board. The unitcomes defaulted to allow settings to be made through the Configuration menus.

Configuring the Unit Using the Configuration Menus

Use the Configuration menu branch of the unit to display or change configurationoption settings.

Configuration Options

The Model 7985 Standalone Termination Unit is shipped with factory settings inthe Default Factory configuration area. You can find default information by:

� Referring to Appendix A, Configuration Option Tables.

� Accessing the Configuration branch of the Model 7985 StandaloneTermination Unit menu.

The Model 7985 Standalone Termination Unit has two sets of configuration optionsettings. The Current Configuration matches the Default Factory Configurationuntil modified and saved by the user.

Configuration Option Area Configuration Option Set

Current Configuration The Model 7985 Standalone Termination Unit’s activeset of configuration options.

Default Factory Configuration A read-only configuration area containing the factorydefault configuration options.

If the factory default settings do not support your network’s configuration, you cancustomize the configuration options for your application.

Page 32: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-6 7985-A2-GB20-00October 1998

Configuring the Unit Using the Internal Switches

Use internal Switchpacks S1 and S2 to manually configure the unit. Use Figure 3-1 to locate Switchpacks S1 and S2.

! HANDLING PRECAUTIONS FORSTATIC-SENSITIVE DEVICESThis product is designed to protect sensitive components from damagedue to electrostatic discharge (ESD) during normal operation. Whenperforming installation procedures, however, take proper static controlprecautions to prevent damage to equipment. If you are not sure of theproper static control precautions, contact your nearest sales or servicerepresentative.

� Procedure

To configure the unit using internal Switchpacks S1 and S2:

1. Power down the unit and remove the enclosure cover, exposing the circuitboard.

2. Locate Switchpack S1 using Figure 3-1.

3. Set switch 1 on Switchpack S1 to ON to enable Switchpacks 1 and 2.

4. After you enable the switchpacks, you must set the switches to your desiredconfiguration. Refer to Figure 3-1 and Table 3-1.

5. Replace and secure the cover.

6. Power up the board to reset and enable the new configuration.

496-15104

Page 33: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-77985-A2-GB20-00 October 1998

Switchpack Locations

Use Figure 3-1 to locate Switchpacks S1 and S2.

98-15937

Switchpack S1 & S2

Front

S2

Rear

S167

8

ON1

23

45

67

8

ON1

23

45

Figure 3-1. Hotwire Model 7985 Standalone Termination Unit Switchpack Locations

Page 34: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-8 7985-A2-GB20-00October 1998

Switchpack Definitions

Manually change configuration options by moving Switchpack S1 DIP switcheson the card. Table 3-1 lists Switchpack S1 definitions.

Table 3-1. Switchpack S1 Definitions

Switch # . . . Allows you to . . . Default in Bold

1 Enables or disables Switchpacks S1 and S2.

OFF = Switchpacks DisabledON = Switchpacks Enabled

2 Controls Sync Port Type.

OFF = EIA-530, RS-449, or X.21ON = V.35

3 Select the unit’s timing source. Only valid for LTU configured units.

OFF = Internal clockON = External Clock

4, 5, 6, 7, 8 Control Sync Port Data Rate (refer to Table 3-2, Selectable PayloadRates)

NOTE: Switches 4 through 8 are only used when the unit isconfigured as an LTU and autorate is disabled.

All OFF = 2048 kbps

Use Table 3-2 to set the Sync Port Payload Rate. Defaults are shown in bold.

NOTE:Sync port and DSL Line Rates can only be selected from units configured asLTU (Switchpack S2 #1) with AutoRate disabled (Switchpack S2 # 2).

Page 35: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-97985-A2-GB20-00 October 1998

Table 3-2. Selectable Payload Rates (Switches 4–8 on Switchpack S1)

Switch Number AssociatedDSL Line

Sync Port Payload Rate 8 7 6 5 4DSL Li neRate

2048 kbps (32 x 64) OFF OFF OFF OFF OFF 2064 kbps

1984 kbps (31 x 64) ON ON ON ON ON 2064 kbps

1920 kbps (30 x 64) ON ON ON ON OFF 2064 kbps

1856 kbps (29 x 64) ON ON ON OFF ON 2064 kbps

1792 kbps (28 x 64) ON ON ON OFF OFF 2064 kbps

1728 kbps (27 x 64) ON ON OFF ON ON 2064 kbps

1664 kbps (26 x 64) ON ON OFF ON OFF 2064 kbps

1600 kbps (25 x 64) ON ON OFF OFF ON 2064 kbps

1536 kbps (24 x 64) ON ON OFF OFF OFF 1552 kbps

1472 kbps (23 x 64) ON OFF ON ON ON 1552 kbps

1408 kbps (22 x 64) ON OFF ON ON OFF 1552 kbps

1344 kbps (21 x 64) ON OFF ON OFF ON 1552 kbps

1280 kbps (20 x 64) ON OFF ON OFF OFF 1552 kbps

1216 kbps (19 x 64) ON OFF OFF ON ON 1552 kbps

1152 kbps (18 x 64) ON OFF OFF ON OFF 1552 kbps

1088 kbps (17 x 64) ON OFF OFF OFF ON 1552 kbps

1024 kbps (16 x 64) ON OFF OFF OFF OFF 1040 kbps

960 kbps (15 x 64) OFF ON ON ON ON 1040 kbps

896 kbps (14 x 64) OFF ON ON ON OFF 1040 kbps

832 kbps (13 x 64) OFF ON ON OFF ON 1040 kbps

768 kbps (12 x 64) OFF ON ON OFF OFF 784 kbps

704 kbps (11 x 64) OFF ON OFF ON ON 784 kbps

640 kbps (10 x 64) OFF ON OFF ON OFF 784 kbps

576 kbps (9 x 64) OFF ON OFF OFF ON 784 kbps

512 kbps (8 x 64) OFF ON OFF OFF OFF 528 kbps

448 kbps (7 x 64) OFF OFF ON ON ON 528 kbps

384 kbps (6 x 64) OFF OFF ON ON OFF 400 kbps

320 kbps (5 x 64) OFF OFF ON OFF ON 400 kbps

256 kbps (4 x 64) OFF OFF ON OFF OFF 272 kbps

192 kbps (3 x 64) OFF OFF OFF ON ON 272 kbps

128 kbps (2 x 64) OFF OFF OFF ON OFF 144 kbps

64 kbps (1 x 64) OFF OFF OFF OFF ON 144 kbps

Page 36: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-10 7985-A2-GB20-00October 1998

Table 3-3 lists Switchpack S2 definitions.

Table 3-3. Switchpack S2 Definitions

Switch # . . . Allows you to . . . Default in Bold

1 Control whether the unit is an LTU or an NTU.

OFF = NTUON = LTU

2 Control enabling and disabling of the Autorate capability.

OFF = Autorate EnabledON = Autorate Disabled

3, 4, 5 Select one of eight preset DSL line rates (refer to Table 3-4).

All OFF = 2064

6, 7 Not used

8 Emergency Use Only – The Model 7985 has two banks of flashmemory used to hold executable firmware This switch allows you toswitch between the two versions of firmware. This switch isindependent from the position of Switch 1 on Switchpack S1(switchpack enable/disable).

OFF = Current FirmwareON = Previous FW

Use Table 3-4 to set the DSL Line Rate. Defaults are shown in bold.

Table 3-4. DSL Line Rate, Switches 3–5 on Switchpack S2

Switch Position

5 4 3 DSL Line Rate

OFF OFF ON 144 kbps

OFF ON OFF 272 kbps

OFF ON ON 400 kbps

ON OFF OFF 528 kbps

ON OFF ON 784 kbps

ON ON OFF 1040 kbps

ON ON ON 1552 kbps

OFF OFF OFF 2064 kbps

Page 37: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-117985-A2-GB20-00 October 1998

Accessing and Displaying Configuration Options

To display configuration options, you must first load a configuration into the editarea.

To load a configuration option set into the configuration edit area, follow thismenu selection sequence:

Main Menu →Configuration (Load Configuration From)

main/configuration HotwireModel: 7985

LOAD CONFIGURATION FROM:

Current ConfigurationConfiguration LoaderDefault Factory Configuration

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit

Î ÎÎ

Make a selection by placing the cursor at your choice and pressing Enter.

If you select . . . Then . . .

CurrentConfiguration

The selected configuration option set is loaded and theConfiguration Edit/Display menu screen appears.

Default FactoryConfiguration

The selected configuration option set is loaded and theConfiguration Edit/Display menu screen appears.

ConfigurationLoader

The Configuration Loader screen is displayed allowing you toupload or download configurations from a TFTP server.

Page 38: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-12 7985-A2-GB20-00October 1998

Configuration Edit/Display

The Configuration Edit/Display screen is displayed when the current, customer, ordefault configuration is loaded. To access the Configuration Edit/Display screen,follow this menu selection sequence:

Main Menu →Configuration →Current Configuration

– or –

Main Menu →Configuration →Default Factory Configuration

ÎÎ

ÎÎÎÎ

main/config/edit HotwireModel: 7985

CONFIGURATION EDIT/DISPLAY

NetworkSYNC PortSystem OptionsCommunication PortManagement and Communication

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit S ave

See Appendix A, Configuration Option Tables, for a list and explanation of theconfiguration options available.

Select . . . To Access the . . . To Configure the . . .

Network Network Interface Options, Table A-1 DSL network interfaces onthe unit.

SYNC Port Synchronous Data Port Options, Table A-2

Synchronous DTE interfacePorts.

SystemOptions

System Options, Table A-3 General system options ofthe unit.

CommunicationPort

Communication Port, Table A-4 Unit’s COM port options.

ManagementandCommunication

� Telnet Sessions Options, Table A-5

� Communication Protocol Options, Table A-6

� SNMP Traps Options, Table A-7

Management support of theunit through SNMP andTelnet.

Page 39: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-137985-A2-GB20-00 October 1998

Configuring AutoRate

The M/HDSL AutoRate function is controlled from the Network Interface Optionsscreen and allows you to enable or disable AutoRate from a unit configured as anLTU. To access the Network Interface screen, follow this menu selectionsequence:

Main Menu →Configuration →Network

ÎÎ

ÎÎÎÎ

main/config/network Hotwire Model: 7985

NETWORK INTERFACE OPTIONS

Margin Threshold: –3dbExcessive Error Rate Threshold: 1E–5AutoRate DisableDSL Line Rate 144

Circuit Identifier: Clear

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit S ave

� Procedure

The AutoRate option is defaulted to Enable. To disable AutoRate:

1. Position the cursor in the AutoRate field and press the spacebar.

The AutoRate field toggles to Disable and the DSL Line Rate field displays.

2. Enter a DSL Line Rate and press Enter.

Your payload rate is set to a default value determined by your LTU DSL LineRate. Use Table 3-5, Fixed Rate Payload Rates and DSL Line Rates, to setyour DSL Line Rate and Payload Rate.

Page 40: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-14 7985-A2-GB20-00October 1998

Table 3-5. Fixed Rate Payload Rates and DSL Line Rates

DSL Line Rate (kbps)

144 272 400 528 784 1040 1552 2064

P64 192 320 448 576 832 1088 1600

Pay

128 256 384 512 640 896 1152 1664ylo

704 960 1216 1728oad

768 1024 1280 1792d

1344 1856 Ra

1408 1920ate

1472 1984e

1536 2048

Configuration Loader

The Configuration Loader screen allows you to upload configurations to anddownload configurations from a TFTP server. To access the Configuration Loaderscreen, follow this menu selection sequence:

Main Menu →Configuration →Configuration Loader

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

main/config/config_loader HotwireModel: 7985

CONFIGURATION LOADER

Image File Name: ClearTFTP Server IP Address: 000 .000 .000 .000 ClearTFTP Transfer Direction: Download from Server

Destination: DSL

Start Transfer: Yes

Packets Sent: 0000000 Packets Received: 0000000 Bytes Sent: 0000000 Bytes Received: 0000000 Transfer Status: Transfer Pending

Activate new configuration? No –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit

Page 41: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-157985-A2-GB20-00 October 1998

� Procedure

To upload or download a configuration:

1. Position the cursor in the Image File Name field. Type the name of the file tobe downloaded, or the name to be used for the file to be uploaded.

The file name may be a regular path name expression of directory namesseparated by a forward slash (/) ending with the file name. The total pathname length can be up to 128 characters.

DOS machine: If the TFTP server is hosted by a DOS machine, thendirectory and file names must consist of eight or less characters with anoptional suffix of up to three characters. The system will automatically uploadthe configuration file and create directories and file names as needed.

UNIX machine: If your server is hosted by a UNIX machine, the configurationfile you name must already exist. It will not be created on the UNIX system bythe TFTP server. It is critical that you work with your system administrator toplan the naming conventions for directories, filenames, and permissions sothat anyone using the system has read and write permissions.

2. Position the cursor in the TFTP Server IP Address field. Enter the TFTPserver IP address.

3. Position the cursor in the Destination field. Use the spacebar to select anetwork destination for the TFTP server. Select DSL if the TFTP serverdestination is the DSL link or COM if the TFTP destination is the COM port.

4. Position the cursor in the TFTP Transfer Direction field. Use the spacebar toselect Download from Server or Upload to Server.

5. Position the cursor at the Start Transfer field. Use the spacebar to select Yes.Press Enter.

When the data transfer is complete, the Transfer Status field changes toCompleted successfully .

6. Position the cursor at the Activate New Configuration field and select Yes toactivate a new downloaded configuration. Press Enter.

NOTE:The configuration options DSL Mode and Telnet Session are not changedwhen a new configuration is loaded. You must change these settings with theappropriate configuration menus after the new configuration is activated. SeeTable A-3, System Options, and Table A-5, Telnet Session Options, inAppendix A, Configuration Option Tables.

Page 42: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-16 7985-A2-GB20-00October 1998

Saving Configuration Options

When changes are made to the configuration options through the ConfigurationEdit/Display branch, the changes must be saved to take effect. Use the Save keyor Save Configuration screen.

� Procedure

To save configuration options changes:

1. Press Ctrl-a to switch to the screen function key area below the dotted line.

2. Select Save and press Enter.

NOTE:When Exit is selected before Save, or Save has been selected from anymenu in the Configuration/Edit branch, a Save Configuration screen appearsrequiring a Yes or No response.

Î ÎÎ

main/config/saveprompt HotwireModel: 7985

SAVE CONFIGURATION

Save Changes? No

WARNING:

An answer of “yes” will cause the systemto reset as if it had been powered off and on!

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit

Command Complete

If the Telnet Session configuration option is changed, a message displays on theSave Configuration screen warning that an answer of Yes will cause the Telnetsession to disconnect. Do not answer Yes unless you are prepared to disconnect.

If the DSL Mode configuration option is changed, a message displays on theSave Configuration screen warning that an answer of Yes will cause the systemto reset. Do not answer Yes unless you are prepared to reset.

If you select . . . Then . . .

Yes The configuration is saved.

No The Main Menu appears and changes are not saved.

Page 43: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-177985-A2-GB20-00 October 1998

Download Code

The Download Code screen allows you to download firmware from a TFTPserver. To access the Download Code screen, follow this menu selectionsequence:

Main Menu →Control →Download Code

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

main/control/download_code HotwireModel: 7985

DOWNLOAD CODE

Image File Name: Clear TFTP Server IP Address: 000 .000 .000 .000 Clear

Destination: DSL

Start Transfer: Yes

Packets Sent: 0000000 Packets Received: 0000000 Bytes Sent: 0000000 Bytes Received: 0000000 Transfer Status: Transfer Pending

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit

� Procedure

To download firmware:

1. Position the cursor in the Image File Name field. Type the name of the file tobe downloaded.

The file name may be a regular path name expression of directory namesseparated by a forward slash (/) ending with the file name. The total pathname length can be up to 128 characters.

2. Position the cursor in the TFTP Server IP Address field. Enter the TFTPserver IP address.

The first three digits of the IP address cannot be 000 or greater than 223.

3. Position the cursor in the Destination field. Use the spacebar to select anetwork destination for the TFTP server. Select DSL if the TFTP serverdestination is the DSL link or COM if the TFTP destination is the COM port.

4. Position the cursor at the Start Transfer field. Use the spacebar to select Yes.Press Enter.

When the data transfer is complete, the Transfer Status field changes toCompleted successfully .

5. Press the Escape key to return to the Control menu. Select Apply Download.

6. On the Apply Download screen, select Yes to reset the card and activate thecode.

Page 44: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Initial Startup and Configuration

3-18 7985-A2-GB20-00October 1998

This page intentionally left blank.

Page 45: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

4-17985-A2-GB20-00 October 1998

Monitoring the Unit

4What to Monitor

This chapter presents information on how to access and monitor Hotwire Model 7985 Standalone Termination Units on the network. You can monitorModel 7985 Standalone Termination Unit operations by viewing:

� System and Test Status screens

� Highest priority Health and Status messages on the last line of all screens

� Network Error Statistics screen

� Network Performance Statistics screen

� Display LEDs screen or LEDs on the Model 7985 Standalone TerminationUnit front panel

Page 46: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Monitoring the Unit

4-2 7985-A2-GB20-00October 1998

Viewing System and Test Status

To view System and Test Status information, follow this menu selectionsequence:

Main Menu →Status → System and Test Status

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

main/status/system Hotwire Model: 7985

SYSTEM AND TEST STATUS Page 1 of 1

HEALTH AND STATUS SELF-TEST RESULTS TEST STATUS–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––LOS at Net, Pt 1 CPU Failed No Test ActiveOOF at Net, Pt 1 Device Failed LLB Test Active, Pt 1EER at Net, Pt 1 Net DSL Failed, Pt 1 RLB Test Active, Pt 1SYNC Pt Down, Pt 1 SYNC Pt Failed, Pt 1 DTLB Test Active, Pt 1Net Margin Threshold, Pt 1 Memory Failed DCLB Test Active, Pt 1Fallback Rate, Pt 1 Failure xxxxxxxx 511 Test Active, Pt 1Devise Failed yyyyyyyy Passed Lamp Test ActiveDownload FailedNet Com Link DownMismatch Rate, Pt 1

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– ESC for previous menu M ainMenu E xitPgUp PgDn

The System and Test Status screen has three sections:

� Health and Status – Displays messages in priority order (highest to lowest).Refer to Table 4-1, Health and Status Messages.

� Self-Test Results – Results of the Diagnostic test run on the device itself.Refer to Table 4-2, Self-Test Results Messages.

� Test Status – Currently active tests. Refer to Table 4-3, Test StatusMessages.

Page 47: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Monitoring the Unit

4-37985-A2-GB20-00 October 1998

Health and Status

The following messages can appear in the first column of the System and TestStatus screen. The highest priority Health and Status message also appears onall ATI screens on the bottom right.

Table 4-1. Health and Status Messages

Message What Message Indicates What To Do

SystemOperational

There are no problemsdetected.

LOS at Net, Pt 1 An LOS (Loss Of Signal)condition has been detectedon the network interface. Nosignal is being received onPort 1, possibly due to a localnetwork problem.

1. Verify that the network cable issecurely attached at both ends.

2. Contact network provider.

OOF at Net, Pt 1 Three consecutive framesynchronization bits were inerror.

1. Check the Transmit Clock Sourceconfiguration options. Do not setboth the local and remote unit toInternal, External, or Loop timing.

2. Contact network provider.

EER at Net, Pt 1 An EER (Excessive ErrorRate) condition has beendetected on the networkinterface at Port 1. Thecondition is cleared when theerror rate falls below thethreshold value currentlyconfigured.

Contact network provider.

SYNC Pt Down,Pt 1

The interchange circuits forPort 1 are configured tomonitor DTR and/or RTS, anda monitored lead is notasserted.

Verify that the DTE is providing themonitored signals.

Net MarginThreshold, Pt 1

The signal-to-noise marginhas exceeded the configuredthreshold for Port 1.

Contact network provider.

Fallback Rate,Pt 1

The LTU, set to AutoRateenable, had a LOS when theline was restored andresynched at a lower rate.

Reset the Termination Unit if theunits do not automatically train up atthe previous rate.

DeviceFailedyyyyyyyy

An internal error has beendetected by the operatingsoftware. yyyyyyyy indicatesthe 8-digit hexadecimal failurecode.

1. Provide the 8-digit failure codeshown (yyyyyyyy ) to your servicerepresentative.

2. Reset the Model 7985Standalone Termination Unit toclear the condition and message.

Page 48: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Monitoring the Unit

4-4 7985-A2-GB20-00October 1998

Table 4-1. Health and Status Messages

Message What To DoWhat Message Indicates

Download Failed A firmware download wasinterrupted.

Repeat the download.

Net Com LinkDown

The Network communicationlink is down. Communicationsbetween the managementsystem and the LTU/NTU isnot possible.

Verify that the network cable issecurely attached at both ends.

Self-Test Results

The results of the last power-up or reset self-test appear in the middle column ofthe System and Test Status screen.

Table 4-2. Self-Test Results Messages

Message What Message Indicates What To Do

CPU Failed The CPU failed internal testing. 1. Reset the unit and try again.

DeviceFailed One or more of the Model 7985Standalone Termination Unit’sintegrated circuit chips has faileddevice-level testing.

2. Call your servicerepresentative for assistance.

Net DSLFailed, Pt 1

The Model 7985 StandaloneTermination Unit failed to loop dataon the network DSL circuit of Port 1.

1. Reset the unit and try again.

2. Call your servicerepresentative for assistance.

SYNC PtFailed, Pt 1

The Model 7985 StandaloneTermination Unit failed to internallyloop data on the synchronous Port 1.

re resentative for assistance.

MemoryFailed

The Model 7985 StandaloneTermination Unit failed memoryverification.

Failurexxxxxxxx

An internal failure occurred.(xxxxxxxx represents an 8-digithexadecimal failure code for use byservice personnel.)

Record the failure code andcontact your servicerepresentative.

Passed No errors were detected.

Page 49: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Monitoring the Unit

4-57985-A2-GB20-00 October 1998

Test Status

The Test Status messages in the following table appear in the right column of theSystem and Test Status screen.

Table 4-3. Test Status Messages

Test Status Message Meaning

No Test Active No tests are currently running.

LLB Test Active, Pt 1 A network Line Loopback test is active on Port 1.

RLB Test Active, Pt 1 A network Repeater Loopback test is active on Port 1.

DTLB Test Active, Pt 1 A Data Terminal Loopback test is active on Port 1.

DCLB Test Active, Pt 1 A Data Channel Loopback test is active on Port 1.

511 Test Active, Pt 1 A 511 Test and Monitor is active on the DSL Port 1 networkinterface.

Lamp Test Active The Lamp Test is active, causing the LEDs on the front panel tolight.

Page 50: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Monitoring the Unit

4-6 7985-A2-GB20-00October 1998

Viewing Network Error Statistics

The Model 7985 Standalone Termination Unit maintains error statistics on thenetwork DSL interface for Port 1. Statistics are maintained for up to 96 15-minuteintervals (24 hours).

To view the Network Error Statistics, follow this menu selection sequence:

Main Menu →Status →Performance Statistics→Network Error Statistics

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

main/status/performance/net_error Hotwire Model: 7985 NETWORK ERROR STATISTICS

Current Interval Timer: 2 Error Events Counter: 34––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– –––ES––– –––SES––– ––FEBE–– –Complete–

Near Far Near Far Near Far Near Far Current Int: 000 000 000 000 000 000 Yes No Interval 01 000 000 000 000 000 000 Yes Yes Interval 02 000 000 000 000 000 000 Yes Yes Interval 03 000 000 000 000 000 000 Yes Yes Interval 04 000 000 000 000 000 000 Yes Yes Interval 05 000 000 000 000 000 000 Yes Yes Interval 06 000 000 000 000 000 000 Yes Yes Interval 07 000 000 000 000 000 000 Yes Yes

Worst Interval: 24 09 14 08 18 18Near Tot(valid): 00010 00000 00000 Far Tot(valid): 00010 00000 00000–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl–a to access these functions, ESC for previous menu M ainMenu E xit PgU p PgD n ClrN ear ClrF ar

Network Error Statistics are collected for:

� ES (Errored Seconds): Seconds during which one or more ESF error eventsoccurred.

� SES (Severely Errored Seconds): Seconds during which more than 320 cyclic redundancy check (CRC) error events or at least one Out of Frame(OOF) event occurred.

� FEBE (Far-End Block Errors): Errors reported by the remote equipment.

� Complete: Whether the interval register contains data for a complete 900-second interval.

Page 51: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Monitoring the Unit

4-77985-A2-GB20-00 October 1998

Use the virtual function keys to page through the intervals and clear statistics.

This Field . . . Contains . . .

Current IntervalTimer

The number of seconds which have elapsed in the current15-minute interval. Maximum value is 900 seconds (15 minutes).This counter resets every 15 minutes.

Error EventsCounter

A running total of CRC errors. Range 0 – 65535. This counterresets when the near-end data is cleared.

Current Interval Performance data for the current 15 minutes.

Interval xx Historical performance data for up to 96 15-minute intervals (24 hours) where the value of xx is from 01 to 96.

Worst Interval The number of the interval with the worst (highest) performancedata for both the near- and far-end statistics. If two or moreintervals are equal, the oldest interval is displayed.

Near and Far TOT A running total of the near- and far-end performance statistics.

Page 52: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Monitoring the Unit

4-8 7985-A2-GB20-00October 1998

Viewing Network Performance Statistics

Network performance statistics allow you to monitor the current status of thenetwork DSL operations. Performance statistics can assist you in determining theduration of specific conditions and provide a historical context for problemdetection and analysis. Statistics are maintained for up to 96 15-minute intervals(24 hours).

To view the Network Performance Statistics, follow this menu selection sequence:

Main Menu →Status →Performance Statistics →Network PerformanceStatistics

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

main/status/performance/net_perf Hotwire Model: 7985 NETWORK PERFORMANCE STATISTICS

Payload Rate 2048 Kbps Current Interval Timer: 2 DSL Line Rate: 2063 kbps––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– ––MrGn–– ––XmtPw– ––RxGn–– –Complete–

Near Far Near Far Near Far Near Far Current Int: +02 +01 +03 +03 +02 +02 Yes Yes Interval 01 +02 +03 +02 Yes No Interval 02 +02 +01 +03 +03 +02 +02 Yes Yes Interval 03 +02 +01 +03 +03 +02 +02 Yes Yes Interval 04 +02 +01 +03 +03 +02 +02 Yes Yes Interval 05 +02 +01 +03 +03 +02 +02 Yes Yes Interval 06 +02 +01 +03 +03 +02 +02 Yes Yes Interval 07 +02 +01 +03 +03 +02 +02 Yes Yes

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl–a to access these functions, ESC for previous menu M ainMenu E xit PgU p PgD n ClrN ear ClrF ar

Use the virtual function keys to scroll through the intervals and clear statistics.

Network Performance Statistics are collected for:

� Mrgn: Margin, the signal-to-noise ratio (SNR) less an SNR reference value.

� XmtPw: The transmit power level.

� RxGn: The receiver gain level.

� Complete: Whether the interval register contains data for a complete 900-second interval.

Page 53: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Monitoring the Unit

4-97985-A2-GB20-00 October 1998

This Field . . . Contains . . .

Current intervaltimer

The number of seconds which have elapsed in the current15-minute interval. Maximum value is 900 seconds (15 minutes).This counter resets every 15 minutes.

Payload Rate The payload rate of the DSL line.

DSL Line Rate The rate of the DSL line.

Current Interval Performance data for the current 15 minutes.

Interval xx Historical performance data for up to 96 15-minute intervals (24 hours) where the value of xx is from 01 to 96.

Viewing Model 7985 Standalone Termination Unit LEDs

The Model 7985 Standalone Termination Unit LEDs can be viewed on the DisplayLEDs Status screen. This ATI status screen is available locally and remotely.

The 3 groups of LEDs are:

� General LEDs display the status of the unit

� Sync Port LEDs provide the status of the DTE interface

� DSL Loop LEDs display the activity on the DSL network

To view the LED status screen, follow this menu selection sequence:

Main Menu →Status → Display LEDs

main/status/leds HotwireModel: 7985

DISPLAY LEDs

GENERAL SYNC PORT DSL LOOP––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

ALRM:Off No DTR/RTS Lnk UpTEST Off

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– ESC for previous menu M ainMenu E xit

Î ÎÎ

The LED status display screen is updated every 5 seconds. For information aboutthe meaning of Model 7985 Standalone Termination Unit LEDs, see Model 7985Standalone Termination Unit LEDs on page 4-10.

Page 54: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Monitoring the Unit

4-10 7985-A2-GB20-00October 1998

Model 7985 Standalone Termination Unit LEDs

The following table contains a description of the LEDs on the Model 7985Standalone Termination Unit front panel.

POWER

ALARM

TESTDSL

DTE

98-16132

7985 M/HDSL

TM

TM

Type LED LED is . . . Indicating . . .

SYSTEM POWER Green

Off

Flashing

Unit has power.

No power to the Unit.

Unit is in minimum mode and a download isrequired.

ALARM Red

Off

Device failure, or Power-On Self-Test (POST)is not complete.

Self-test passed.

TEST Yellow

Yellow,flashing

Off

Loopback test or 511 test pattern in progress.

Self-test in progress.

No tests.

DSL DSL Green

Amber

Amber,flashing

Off

DSL link is up.

DSL training in progress.

An OOF condition exists.

The DSL Link is down.

SYNC Port DTE Green

Amber

Amber,flashing

Interchange circuits for the port are in thecorrect state to transmit and receive data.

The port is configured to monitor DTR and/orRTS and no monitored lead is asserted.

The Data Channel or Data Terminal loopbackis active.

Page 55: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

5-17985-A2-GB20-00 October 1998

Testing

5Accessing the Test Menu

From the Test menu, you can run network tests, data port tests, and a lamp testfor the front panel LEDs.

To access the Test menu, follow this menu selection sequence:

Main Menu →Test

ÎÎ

ÎÎÎÎ

main/test HotwireModel: 7985

TEST

Network TestsSYNC Data Port TestsDevice Tests

Abort All Tests

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit

Select . . . To . . .

Network Tests Start and stop tests on the network interface.

SYNC Data Port Tests Start and stop tests on the SYNC Port interface.

Device Tests Start and stop lamp test.

Abort All Tests To abort all current tests. Network-initiated tests will notbe affected. An aborted test may continue to run for afew seconds as the abort command is sent to theremote end and processed.

Page 56: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Testing

5-2 7985-A2-GB20-00October 1998

Running Network Tests

Network tests require the participation of your network service provider. Toaccess the Network Tests screen, follow this menu selection sequence:

Main Menu →Test →Network Tests

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

main/test/network HotwireModel: 7985

NETWORK TESTS

Test Command Status Results ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Local Loopbacks Line Loopback: Start Inactive 00:00:00 Repeater Loopback: Start Inactive 00:00:00

Remote Loopbacks Send Line Loopback: Down Send Inactive 00:00:00

Pattern Tests Send and Monitor 511 Stop Active hh:mm:ss - Errors 99999+

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit R esetMon

Use the Command column to start or stop a test. When the Status columnshows that a test is Inactive, Start is displayed; when a test is Active, Stop isdisplayed. Position the cursor at the desired Start or Stop command and pressEnter.

Selecting a Stop command on the Network Tests screen or Abort All Tests fromthe Test menu will not disrupt a network-initiated loopback.

The Results column displays the test duration.

When the Send and Monitor 511 test is active, ResetMon is available to reset theerror counter to zero.

Page 57: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Testing

5-37985-A2-GB20-00 October 1998

Line Loopback

Line Loopback (LLB) loops the received signal on the network interface back tothe network without change.

98-15931

NTU/LTU

NetworkInterface All 1sPort

InterfaceFramer EIA-530

PortCAP

� Procedure

To run a Line Loopback:

1. Position the cursor at the Start command next to Line Loopback on theNetwork Tests screen.

2. Press Enter.

The Start command is changed to Stop.

3. To manually stop the test, verify that the cursor is positioned at the Stopcommand.

4. Press Enter.

Line Loopback cannot be started when a Repeater Loopback, Data ChannelLoopback (DCLB), Remote DCLB, or network-initiated Line Loopback is inprogress.

Page 58: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Testing

5-4 7985-A2-GB20-00October 1998

Repeater Loopback

Repeater Loopback (RLB) loops the signal being sent from the data port back tothe data port and to the network interface.

98-15932

NTU/LTU

NetworkInterface

PortInterface

Framer EIA-530Port

CAP

� Procedure

To run a Repeater Loopback:

1. Position the cursor at the Start command next to Repeater Loopback on theNetwork Tests screen.

2. Press Enter.

The Start command is changed to Stop.

3. To manually stop the test, verify that the cursor is positioned at the Stopcommand.

4. Press Enter.

Repeater Loopback cannot be started when a Line Loopback, DCLB, RemoteDCLB, or Data Terminal Loopback (DTLB) is active.

NOTE:If a disconnected DSL loop is connected while a Repeater Loopback isactive, the connected units will not be able to synchronize.

Page 59: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Testing

5-57985-A2-GB20-00 October 1998

Send Remote Line Loopback

The LTU initiates the test by sending a line loopback up or down command to theremote unit for 10 seconds. When the remote unit detects the loopback upcommand, it puts itself in line loopback and lights the front panel test LED. Theremote unit remains in loopback until it receives a loopback down command. Thesend line loopback tests both units. External equipment can be used to verify thelink.

98-15939-01

NTU/LTU

PortInterface

Framer EIA-530Port

CAP All 1s

NTU/LTU

PortInterface

Framer CAP

Local Remote

� Procedure

To run a Remote Send Line Loopback:

1. Position the cursor at the Up or Down selection next to Send Line Loopbackon the Network Tests screen.

2. Press the spacebar to select either Up or Down.

3. Position the cursor at the Send command next to Up or Down selection.

4. Press Enter.

The loopback stops automatically after 10 seconds. You cannot stop the testmanually.

The Send Remote Line Loopback cannot be started when any other loopback ora Send and Monitor 511 test is active on the network interface.

Page 60: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Testing

5-6 7985-A2-GB20-00October 1998

Send and Monitor 511

The LTU initiates the test by lighting the Test LED sending a command to theremote unit to send a 511 test pattern. When the remote unit detects thecommand, it sends a 511 pattern and lights the front panel test LED. Each unitwill send and monitor the 511 pattern. The duration and results of the test aredisplayed on the Network Test screen of each unit.

NOTE:The send and monitor test is not a loopback test. Each unit independentlysends and monitors a 511 pattern.

98-15936

NTU/LTU

EIA-530Port

All 1s

NTU/LTU

Local Remote

All 1s

511 Pattern

CAP

511Gen

511Mon

CAP

511Mon

511Gen

FramerPortInterface

Framer PortInterface511 Pattern

� Procedure

To run a Send and Monitor 511 test:

1. Position the cursor at the Start command next to Send and Monitor 511 onthe Network Tests screen.

2. Press Enter.

The Start command is changed to Stop.

3. To manually stop the test, verify that the cursor is positioned at the Stopcommand.

4. Press Enter.

When a Send and Monitor 511 test is active, a count of bit errors is displayed nextto the test duration, and the ResetMon virtual function key is available for use.Type r or R or select the ResetMon virtual function key to reset the error count.

Page 61: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Testing

5-77985-A2-GB20-00 October 1998

Running SYNC Data Port Tests

To access the SYNC Data Port Tests screen, follow this menu selectionsequence:

Main Menu →Test →SYNC Data Port Tests

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

main/test/data Hotwire Model: 7985

SYNC DATA PORT TESTS

Test Command Status Results ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Local Loopbacks Data Terminal Loopback: Start Inactive 00:00:00 Data Channel Loopback: Start Inactive 00:00:00

Remote Loopbacks Send Remote DCLB: Down Send Inactive 00:00:00

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit

Use the Command column to start or stop a test. When the Status columnshows that a test is Inactive, Start is displayed; when a test is Active, Stop isdisplayed. Position the cursor at the desired Start or Stop command and pressEnter.

The Results column displays the test duration.

Page 62: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Testing

5-8 7985-A2-GB20-00October 1998

Data Terminal Loopback

Data Terminal Loopback (DTLB) loops the user data back to the DTE. Thisloopback is located as closely as possible to the user data port (DTE) interface.

98-15933

NTU/LTU

NetworkInterface

PortInterface

Framer EIA-530Port

CAPAll 1s

� Procedure

To run a Data Terminal Loopback:

1. Position the cursor at the Start command next to Data Terminal Loopback onthe SYNC Data Port Tests screen.

2. Press Enter.

The Start command is changed to Stop.

3. To manually stop the test, verify that the cursor is positioned at the Stopcommand.

4. Press Enter.

Data Terminal Loopback cannot be started when a Repeater Loopback, DCLB, orRemote DCLB is already active on the data port.

Page 63: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Testing

5-97985-A2-GB20-00 October 1998

Data Channel Loopback

Data Channel Loopback (DCLB) loops the data from the network interface backto the network. This loopback is located as closely as possible to the user dataport (DTE) interface.

98-15934

NTU/LTU

NetworkInterface

PortInterface

Framer EIA-530Port

CAP All 1s

� Procedure

To run a Data Channel Loopback:

1. Position the cursor at the Start command next to Data Channel Loopback onthe SYNC Data Port Tests screen.

2. Press Enter.

The Start command is changed to Stop.

3. To manually stop the test, verify that the cursor is positioned at the Stopcommand.

4. Press Enter.

Data Channel Loopback cannot be started when any of the following tests isactive: Send and Monitor 511, Line Loopback, or Repeater Loopback on thenetwork interface, or a Data Terminal Loopback on the data port.

Page 64: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Testing

5-10 7985-A2-GB20-00October 1998

Send Remote Data Channel Loopback

The local termination unit can send an Up or Down sequence to request the startor stop of a Data Channel Loopback (DCLB) on a remote unit.

98-15935

NTU/LTU

PortInterface

Framer EIA-530Port

CAP All 1s

NTU/LTU

PortInterface

Framer CAP

Local Remote

� Procedure

To send a Remote DCLB:

1. Position the cursor at the Up or Down selection next to Send Remote DCLBon the SYNC Data Port Tests screen.

2. Press the spacebar to select the desired code (Up or Down).

3. Position the cursor at the Start command next to Send Remote DCLB on theSYNC Data Port Tests screen.

4. Press Enter.

The Status field is changed to Sending. The Up or Down sequencetransmission stops automatically after 10 seconds. You cannot stop thesequence manually.

The Send Remote DCLB test cannot be started when a Send and Monitor 511test is active on the network interface.

Page 65: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Testing

5-117985-A2-GB20-00 October 1998

Device Tests

The Device Tests branch is used to access the only card-level test, the LampTest. To access the Device Tests screen, follow this menu selection sequence:

Main Menu →Test →Device Tests

main/test/device HotwireModel: 7985

DEVICE TESTS

Test Command Status––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Lamp Test: Start Inactive

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit

Î ÎÎ

Lamp Test

The Lamp test determines whether all LEDs are lighting and functioning properly.

� Procedure

To test the LEDs:

1. Position the cursor at the Start command next to Lamp Test on the CardTests screen.

2. Press Enter.

The Start command is changed to Stop. During the Lamp test, all LEDs blinksimultaneously every second. When you stop the Lamp test, the LEDs arerestored to their normal condition.

3. To stop the lamp test, position the cursor at the Stop command.

4. Press Enter.

Page 66: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Testing

5-12 7985-A2-GB20-00October 1998

Ending an Active Test

Except for the Remote Send Line Loopback and Remote DCLB, a test initiated bythe user can be ended by the user. Tests can also be terminated automatically byenabling the Test Timeout option from the System Options Menu.

� A Test Timeout option is available to automatically terminate a user-initiatedLoopback or Pattern test (as opposed to manually terminating a test) after ithas been running a specified period of time. The default is 10 minutes. Referto Table A-3, System Options.

Test Timeout does not pertain to tests initiated by the network.

� On each test screen is a Command column. To stop the test, press Enterwhen the cursor is on the Stop command.

� Use the Abort All Tests selection from the Test menu to stop all tests runningon all interfaces, with the exception of network-initiated loopbacks. CommandComplete appears when all tests on all interfaces have been terminated.

An aborted test may continue to run for a few seconds as the abort commandis sent to the remote end and processed.

Page 67: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

6-17985-A2-GB20-00 October 1998

Messages and Troubleshooting

6Overview

There are many messages available to assess the status of the device andcontribute to problem resolutions. Refer to the following sections:

� Configuring SNMP Traps

� Device Messages

� Troubleshooting

Page 68: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Messages and Troubleshooting

6-2 7985-A2-GB20-00October 1998

Configuring SNMP Traps

An SNMP trap can be automatically sent out through the EOC or theManagement port to an SNMP manager when the Model 7985 StandaloneTermination Unit detects conditions set by the user. These traps enable theSNMP manager to gauge the state of the network. Refer to Appendix B,Standards Compliance for SNMP Traps, for details of SNMP traps supported bythe Model 7985 Standalone Termination Unit.

To configure the Model 7985 Standalone Termination Unit for SNMP traps, usethe SNMP Traps Options screen to:

� Enable SNMP traps.

� Set the number of SNMP managers that receive SNMP traps from the Model 7985 Standalone Termination Unit by entering an IP address andnetwork destination for each SNMP manager specified.

� Select the type of SNMP traps to be sent from the Model 7985 StandaloneTermination Unit.

To configure SNMP Traps, follow this menu selection sequence:

Main Menu →Configuration →Load Configuration From →Management and Communication Options →SNMP Traps Options

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

main/config/management/trap HotwireModel: 7985

SNMP TRAPS OPTIONS

SNMP Traps: Enable Number of Trap Managers: 5

NMS 1 IP Address: 135 .014 .040 .001 Clear Destination: DSL NMS 2 IP Address: 135 .014 .003 .027 Clear Destination: DSL NMS 3 IP Address: 135 .014 .001 .008 Clear Destination: DSL NMS 4 IP Address: 135 .014 .002 .024 Clear Destination: DSL NMS 5 IP Address: 204 .128 .146 .035 Clear Destination: DSL

General Traps: Both Enterprise Specific Traps: Enable Link Traps: Both Link Traps Interfaces: Network

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions, ESC for previous menu M ainMenu E xit S ave

Refer to Table A-7, SNMP Traps Options.

Page 69: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Messages and Troubleshooting

6-37985-A2-GB20-00 October 1998

Device Messages

The Device Messages in Table 6-1, listed in alphabetical order, can appear in themessages area at the bottom of the ATI screens.

Table 6-1. Device Messages (1 of 2)

Device Message What Message Indicates What To Do

Access level isOperator.Configuration isread-only.

The operator requested thatconfiguration options beloaded, but does not haveauthority to edit them.

If configuration options are to beedited, use a Login ID that hasAdministrator authority.

Cannot Save – noLogin IDs with AccessAdministrator

All of the login IDs beingsaved have an access levelbelow Administrator.

Change the access level of atleast one Login ID toAdministrator so thatconfiguration changes can bemade. (Operator-level userscannot make configurationchanges.) Save the Login IDs.

Command Complete Action requested hassuccessfully completed.

No action needed.

Invalid Character (x ) A nonprintable ASCIIcharacter (x) has beenentered.

Reenter information using validcharacters.

Invalid – DataTerminal InitiatedLoopback Active

Network-initiated loopbackwas in progress whenanother selection wasmade.

No action needed.

Invalid Password Login is required and anincorrect password wasentered; access is denied.

� Try again.

� Contact your systemadministrator to verify yourpassword.

Invalid – Send PatternAlready Active

A pattern test was alreadyin progress when the Startfield was selected.

� Allow test to continue.

� Select another test.

� Stop the test.

Invalid – [Test ]Already Active

The described test wasalready in progress whenanother selection wasmade.

� Allow test to continue.

� Select another test.

� Stop the test.

Invalid TestCombination

A loopback or pattern testwas in progress when Startwas selected to startanother test, or was activeon the same or anotherinterface when Start wasselected.

� Wait until other test ends andmessage clears.

� Abort all tests from the Testmenu screen.

� Stop the test from the samescreen the test was startedfrom.

Page 70: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Messages and Troubleshooting

6-4 7985-A2-GB20-00October 1998

Table 6-1. Device Messages (2 of 2)

Device Message What To DoWhat Message Indicates

Invalid entry at cursor(1...223, excluding127)

Invalid range. Enter a value within the IPaddress range.

Limit of six Login IDsreached

An attempt to enter a newlogin ID was made, and thelimit of six login/passwordcombinations has beenreached.

1. Delete another login/passwordcombination.

2. Reenter the new login ID.

No Security Recordsto Delete

Delete was selected fromthe Administer Loginscreen, and no securityrecords had been defined.

� No action needed.

� Enter a security record.

Password MatchingError – Re-enterPassword

Password entered in theReenter Password field ofthe Administer Loginsscreen does not matchwhat was entered in thePassword field.

� Try again.

� Contact your systemadministrator to verify yourpassword.

Please Wait Command takes longerthan five seconds.

Wait until message clears.

Test Active A test is running and nohigher priority health andstatus messages exist.

� Contact service provider if testinitiated by the network.

� Wait until the other test endsand message clears.

� Cancel all tests from the Testscreen.

� Stop the test from the samescreen the test was startedfrom.

0.0.0.0 is an invalid IP address

An IP address of all zeroeswas entered.

Enter a valid, non-zero IPaddress.

Page 71: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Messages and Troubleshooting

6-57985-A2-GB20-00 October 1998

Troubleshooting

This Model 7985 Standalone Termination Unit is designed to provide you withmany years of trouble-free service. If a problem occurs, however, refer to Table 6-2 for possible solutions.

Table 6-2. Troubleshooting (1 of 2)

Symptom Possible Cause Solutions

Alarm LED is on. One of several alarmconditions exists. Healthand Status displays thealarm condition.

Refer to Table 4-1, Health and StatusMessages, for recommended action.

Cannot access theunit via the ATI.

The terminal is not set upfor the correct rate or dataformat, or the unit isconfigured so it preventsaccess.

� Check the cable and connections.

� Ensure the unit is configuredproperly. Verify it’s IP address andcommunication port usage.

� Reset the unit.

Device Fail appearson the System andTest Status screenunder Self-Testresults.

The unit detects an internalsoftware failure.

� Reset the unit.

� Contact your servicerepresentative.

No power, or theLEDs are not lit.

The power cord is notsecurely plugged into thewall receptacle and into therear panel connection.

Check that the power cord issecurely attached at both ends.

The wall receptacle has nopower.

� Check the wall receptacle powerby plugging in some equipmentthat is known to be working.

� Check the circuit breaker.

� Verify that your site is not on anenergy management program.

Power supply has failed. Replace power supply.

An LED is not lit. LED is out. Run the Lamp test. If the LED inquestion does not flash with the otherLEDs, then contact your servicerepresentative.

Page 72: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Messages and Troubleshooting

6-6 7985-A2-GB20-00October 1998

Table 6-2. Troubleshooting (2 of 2)

Symptom SolutionsPossible Cause

Not receiving data. � The network or data portcables are notconnected (check frontpanel LEDs for moreinformation).

� A test is being executed

� Check network and data portcables.

� Run Loopback tests. Refer toChapter 5, Testing.

� Stop the test or wait for the test to� A test is being executed

on the unit (check theTEST LED on the frontpanel).

� The far-end device isoffline.

� Stop the test or wait for the test toend.

� Make sure the far-end device ison.

Power-Up Self-Testfails. Only AlarmLED is on afterpower-up.

The unit has detected aninternal hardware failure.

� Reset the unit and try again.

� Contact your servicerepresentative.

Page 73: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

7-17985-A2-GB20-00 October 1998

Security

7Overview

The Model 7985 Standalone Termination Unit provides several methods ofsecurity by limiting user access to the ATI through option settings. You can:

� Enable the Telnet Login Required option.

� Limit the access by setting a Session Access Level option of Operator for theTelnet Session.

� Disable the access with the Telnet Session option.

See Table A-5, Telnet Sessions Options, in Appendix A, Configuration OptionTables.

ATI Access Levels

The Model 7985 Standalone Termination Unit has two access levels:Administrator and Operator. The access level determines what functions areaccessible, as shown in Table 7-1.

Table 7-1. Access Levels

ATI Access to Menu Functions Administrator Operator

Status Read-Only Read-Only

Test Full Access No Access

Configuration Full Access Read-Only

Control Full Access No Access

The effective access level is the more restrictive of the session access level orthe login access level.

Page 74: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Security

7-2 7985-A2-GB20-00October 1998

Access level is also used to control access via Telnet. If the Telnet SessionAccess Level is set to Administrator (see Table A-5, Telnet Session Options), aLogin ID with an Operator access level is not permitted access.

Creating a Login

Logins apply to the terminal directory connected to the communication port orTelnet access directly to the ATI of the Model 7985 Standalone Termination Unit.

Six login ID/password combinations are available. Each Login ID and Passwordmust be unique and include an access level.

� Procedure

1. To create a login record, follow this menu selection sequence:

Main Menu →Control →Administer Logins

main/control/admin_logins HotwireModel: 7985

ADMINISTER LOGINS Page 1 of x

Login ID: newuserAccess Level: Administrator

Are you sure? Yes

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– ESC for previous menu M ainMenu E xit

S ave PgU p PgD n New Del ete

ÎÎ

ÎÎÎÎ

2. Select Newuser and press Enter. The Login Entry screen is displayed.

main/control/admin_logins HotwireSlot: 4 Model: 7985

LOGIN ENTRY

Login ID: newuser2 Password: es342 Re-enter Password: es342 Access Level: Administrator

WARNING New logins will not become permanent until saved

through the “ADMINISTER LOGINS” screen!

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Ctrl-a to access these functions ESC for previous menu M ainMenu E xit S ave

ÎÎ

ÎÎÎÎ

Page 75: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Security

7-37985-A2-GB20-00 October 1998

3. Create the login by entering the following fields. Login IDs and passwords arecase-sensitive.

On the Login Entryscreen, for the . . . Enter . . .

Login ID 1 to 10 ASCII printable characters (hex21 through 7E).Blanks are not allowed.

Password 1 to 10 ASCII printable characters that can consist of0–9, a–z, A–Z, # (pound), . (period), – (dash), and / (slash).

Re-enter Password 1 to 10 ASCII printable characters characters that canconsist of 0–9, a–z, A–Z, # (pound), . (period), – (dash), and / (slash).

Access Level Administrator, Operator

NOTE:Assign at least one Administrator-level Login ID. Full access is necessaryto make configuration option changes and administer logins.

4. Press Ctrl-a to switch to the screen function key area below the dotted line.Select Save and press Enter.

5. When Save is complete, Command Complete appears at the bottom of thescreen.

6. If additional logins are required, repeat Steps 3 through 5.

7. When all logins are entered, press Esc to return to the Administer Loginsscreen.

8. Select Save and press Enter.

Page 76: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Security

7-4 7985-A2-GB20-00October 1998

Deleting a Login

� Procedure

1. To delete a login record, follow this menu selection sequence:

Main Menu →Control →Administer Logins

2. Select PgUp or PgDn and press Enter to page through login pages/recordsuntil you find the one to be deleted.

3. Once the correct record is displayed, select Delete and press Enter.

4. To complete the delete action, select Save and press Enter.

When the deletion is complete, Command Complete appears at the bottomof the screen. The number of login pages/records reflects one less record,and the record following the deleted record appears.

Resetting the Termination Unit’s COM Port or Factory Defaults

Misconfiguring the termination unit could render the user interface inaccessible,leaving it in a state where a session cannot be started via the COM port or aTelnet session. If this occurs, the termination unit connectivity can be restored viaa terminal directly connected to the COM port.

Two methods can be used to restore access to the user interface:

� Reset COM Port – Allows you to reset the configuration options related toCOM port usage. This also causes a device reset, where the termination unitperforms a Device Self-Test. No security-related configuration options arechanged.

� Reload Factory Defaults – Allows you to reload the Default FactoryConfiguration, resetting all of the configuration and control settings whichcauses the current configuration to be destroyed and a device reset. Thismethod is also useful when the user’s password(s) have been forgotten.

� Procedure

To reset COM port settings:

1. At the terminal that is directly connected to the unit’s COM port, configure theterminal to operate at 9.6 kbps, using character length of 8 bits, with onestop-bit, and no parity.

2. Reset the unit, then immediately and repeatedly press Enter at a rate ofabout 1 press per second until the System Paused screen appears.

3. Tab to the desired method, and enter yes (or y) for the selected prompt.

Page 77: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Security

7-57985-A2-GB20-00 October 1998

If entering yes to prompt . . . Then . . .

Reset COM Port usage � Port type is set to Terminal

� Data Rate (kbps) is set to 9.6

� Character Length is set to 8

� Stop Bits is set to 1

� Parity is set to None

Reload Factory Defaults Yes (or y) will restore all factory-loadedconfiguration and control settings contained in theDefault Factory Configuration area are loaded.

If no (or n) is entered, or if no selection is made within 30 seconds, the unitreturns to the condition or operation it was in when the system reset wasinitiated, with the COM port rate returning to its configured rate.

The termination unit resets itself, going through a self-test. Connectivity isrestored and the Main Menu screen appears.

Page 78: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Security

7-6 7985-A2-GB20-00October 1998

This page intentionally left blank.

Page 79: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

8-17985-A2-GB20-00 October 1998

IP Addressing

8Selecting an IP Addressing Scheme

The NTU’s network interface IP address is assigned through the peer IP addressof the LTU’s Network Interface menu. The NTU obtains the LTU’s IP address andsubnet mask when the PPP link is established over the EOC. The LTU IPaddress and subnet mask are configured from the Communication ProtocolOptions menu.

The Model 7985 Standalone Termination Unit is assigned an IP address andsubnet through the Peer IP address of the M/HDSL Network interface menu.Once the address is assigned, you can use the Model 7985 StandaloneTermination Unit’s ATI to assign:

� An IP address for each NMS to act as a trap manager. See Table A-7, SNMP Traps Options, in Appendix A, Configuration Option Tables.

� An IP address for the TFTP server you wish to use to upload and downloadconfigurations. See Configuration Loader in Chapter 3, Initial Setup andConfiguration.

Review the following information in preparation for selecting an IP addressingscheme.

� Any legal host address is allowed for a given subnet. The address choicewithin the subnet is arbitrary.

� A single route to a subnet is all that is needed to reach every device on asubnet.

Page 80: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

IP Addressing

8-2 7985-A2-GB20-00October 1998

IP Addressing Example

98-16133

DSLAM

DSLAM

7985

7985

7985

MCC BaseAddress = 126.35.50.1

MCC Base SubnetMask = 255.255.255.0

Port 1Peer IP Address = 126.35.50.5

MCCLTU8776

Port 2Peer IP Address = 126.35.10.1

Port 3Peer IP Address = 126.35.10.2

Port 4Peer IP Address = 126.35.10.3

NTU8776 MCC

MCC BackplaneAddress = 126.35.1.1

MCC BackplaneMask = 255.255.0.0

7985

NTU IP Address = 126.35.7.2(LTU Peer IP Address)

LTU IP Address = 126.35.7.1LTU Peer IP Address = 126.35.7.2

7985

Peer IP Address Assignments

� The Peer IP Address refers to the IP address of the unit configured as anNTU.

� The Peer IP Address is assigned by the LTU.

Page 81: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

A-17985-A2-GB20-00 October 1998

Configuration Option Tables

AOverview

The tables in this appendix summarize the configuration options accessed whenyou select the Configuration option on the Main Menu. The Configuration optionsare arranged into groups based upon functionality.

Select . . . To Access the . . . To Configure the . . .

Network Network Interface Options, Table A-1 HDSL network interfacePorts.

SYNC Port Synchronous Data Port Options, Table A-2

Synchronous DTE interfacePort.

System System Options, Table A-3 General system options ofthe unit.

CommunicationPort

Communication Port, Table A-4 Unit’s COM port options.

ManagementandCommunication

� Telnet Session Options, Table A-5

� Communication Protocol Options, Table A-6

� SNMP Traps Options, Table A-7

Management support of theunit through SNMP andTelnet.

NOTE:All changes to configuration options must be saved. Refer to SavingConfiguration Options in Chapter 3, Initial Startup and Configuration.

Page 82: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-2 7985-A2-GB20-00October 1998

Network Interface Options Menu

For Network Interface Options, refer to Table A-1. To access the NetworkInterface Options screen, follow this menu selection sequence:

Main Menu →Configuration →Current Configuration → Network

Table A-1. Network Interface Options (1 of 2)

Margin Threshold

Possible Settings: –5db , –4db , –3db , –2db , –1db , 0db , 1db , 2db , 3db , 4db , 5db , 6db ,7db , 8db , 9db , 10db Default Setting: 0db

Determines the level, expressed in decibels, at which a signal-to-noise margin conditionis recognized.

–5db to 10db – Sets the margin threshold to this value.

Excessive Error Rate Threshold

Possible Settings: 1E–4, 1E–5, 1E–6, 1E–7, 1E–8, 1E–9Default Setting: 1E–6

Determines the error rate at which an excessive error rate (EER) condition isrecognized. The rate is the ratio of the number of CRC errors to the number of bitsreceived in a certain period.

AutoRate

Possible Settings: Enable, DisableDefault Setting: Enable

Specifies whether the DSL line will automatically train up to the best rate or be userselectable. This option is only available when the standalone unit is configured as anLTU.

Enable – The LTU is set to automatically adjust at the best line rate.

Disable – The LTU Line rate is user selectable and is based on the DSL Line Rateselected.

DSL Line Rate

Possible Settings: 144, 272, 400, 528, 784, 1040, 1552, 2064Default Setting: 144

Specifies the DSL line rate of the unit. This option is only available when the standaloneunit is configured as an LTU and AutoRate is disabled (unit is in fixed rate).

144 – Available payload rates are: 64 and 128 kbps.

272 – Available payload rates are: 192 and 256 kbps.

400 – Available payload rates are: 320 and 384 kbps.

528 – Available payload rates are: 448 and 512 kbps.

784 – Available payload rates are: 576, 640, 704, and 768 kbps.

1040 – Available payload rates are: 832, 896, 960, and 1024 kbps.

1552 – Available payload rates are: 1088, 1152, 1216, 1280, 1344, 1408, 1472, and1536 kbps.

2064 – Available payload rates are: 1600, 1664, 1728, 1792, 1856, 1920, 1984, and2048 kbps.

Page 83: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-37985-A2-GB20-00 October 1998

Table A-1. Network Interface Options (2 of 2)

Peer IP Address

Possible Settings: 000.000.000.001 – 223.255.255.255, ClearDefault Setting: 000.000.000.001

Specifies the peer IP address for the remote management providing the remotemanagement link on the DSL loop. This option is only available when the standaloneunit is configured as an LTU.

000.000.000.001 – 223.255.255.255 – Enter an address for the peer unit. The range forthe first byte is 000 to 223, with the exception of 127. The range for the remaining threebytes is 000 to 255. The peer IP address must be in the same subnet as the MCCaddress.

Clear – Clears the IP address field and sets to all zeros.

Circuit Identifier

Possible Settings: [ASCII Text], ClearDefault Setting: [blank]

Uniquely identifies the circuit number of the transmission vendor’s DSL line fortroubleshooting purposes.

[ASCII Text] – Enter a maximum of 128 characters. All printable ASCII charactersexcept ^ (caret) are allowed.

Clear – Clears the field.

Page 84: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-4 7985-A2-GB20-00October 1998

Synchronous Data Port Options Menu

For Synchronous Data Port Options, refer to Table A-2. To access theSynchronous Data Port Options screen, follow this menu selection sequence:

Main Menu →Configuration →Load Configuration From →SYNC Ports

Table A-2. Synchronous Data Port Options (1 of 3)

Port Type

Possible Settings: E530A, V.35, RS449, X.21Default Setting: E530A

Determines the port type for the data port.

E530A – The port is configured as an EIA-530A compatible DCE. An EIA-530compatible DTE can be connected directly to the DB25 Port connector on the rear panelof the unit.

V.35 – The port is configured as a V.35 compatible DCE. A V.35 compatible DTE can beconnected using an MS34 to DB25 adaptor cable to connect to the DB25 Portconnector on the rear panel of the unit.

E530A – The port is configured as an RS449 compatible DCE. An RS449 compatibleDTE can be connected using a DB37 to DB25 adaptor cable to connect to the DB25Port connector on the rear panel of the unit.

X.21 – The port is configured as an X.21 compatible DCE. An X.21 compatible DTE canbe connected using a DB15 to DB25 adaptor cable to connect to the DB25 Portconnector on the rear panel of the unit.

Payload Rate

Possible Settings: 64, 128, 192, 256, 320, 384, 448, 512, 576, 640, 704, 768, 832, 896,960, 1024, 1088, 1152, 1216, 1280, 1344, 1408, 1472, 1536, 1600, 1664, 1728, 1792,1856, 1920, 1984, 2048Default Setting: 128

Specifies the payload rate of the port. This option is not displayed on the unit whenAutoRate is enabled or the unit is configured as an NTU. The LTU configures thepayload rate for the NTU when AutoRate is disabled.

64 to 2048 – Sets the payload rate in kbps when AutoRate is disabled (unit isconfigured as fixed rate).

Transmit Clock Source

Possible Settings: Internal, ExternalDefault Setting: Internal

Specifies whether the transmitted data for the synchronous data port is clocked usingan internal clock provided by the LTU (synchronized to the clock source specified by theclock source configuration option) or an external clock provided by the DTE connectedto the synchronous data port. If an external clock is used, it must be synchronized to thesame clock source as the LTU.

Internal – Indicates the clock is provided internally by the 7985 Termination Unit on theTXC interchange circuit DB (CCITT 114).

External – Indicates the clock is provided externally by the DTE on the XTXCinterchange circuit DA (CCITT 113). Use this selection if the clock source is set to thedata port.

Page 85: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-57985-A2-GB20-00 October 1998

Table A-2. Synchronous Data Port Options (2 of 3)

Invert Transmit Clock

Possible Settings: Disable, EnableDefault Setting: Disable

Specifies whether the clock supplied by the Model 7985 Termination Unit on the TXCinterchange circuit DB (CCITT 114) is phase inverted with respect to the TransmittedData interchange circuit BA (CCITT 103). This configuration option is useful when longcable lengths between the Model 7985 Termination Unit and the DTE are causing dataerrors.

Disable – Indicates TXC supplied by the Model 7985 Termination Unit on this port is notphase inverted.

Enable – Indicates TXC supplied by the Model 7985 Termination Unit on this port isphase inverted.

Send All Ones on Data Port Not Ready

Possible Settings: Both, Disable, DTR, RTSDefault Setting: Both

Specifies the conditions on the data port that determine when valid data is not beingsent from the DTE. When this condition is detected, all ones are sent to the network.

Both – Monitors both DTR and RTS. If either is interrupted, all ones are sent to thenetwork.

Disable – Disables the monitoring of interchange circuits from the DTE connected tothe synchronous data port.

DTR – Monitors the DTE Ready interchange circuit CD (CCITT 108/1/2). When DTR isinterrupted, all ones are sent to the network.

RTS – Monitors the Request-to-Send interchange circuit CA (CCITT 105). When RTS isinterrupted, all ones are sent to the network.

Action on Network LOS Alarm

Possible Settings: Halt, NoneDefault Setting: Halt

Specifies the action taken on the synchronous data port when an LOS (Loss Of Signal)alarm is received on the network interface.

Halt – Stops the transmission of data on the data port and disables the data port whenan LOS alarm is received on the network interface. When LOS alarms are received, allones are sent on the Received Data interchange circuit BB (CCITT 104). TheClear-to-Send interchange circuit CB (CCITT 106) is interrupted.

None – Makes the data port unaffected by LOS alarms received on the networkinterface.

Network Initiated Data Channel Loopback

Possible Settings: Disable, EnableDefault Setting: Disable

Allows the initiation and termination of a Data Channel Loopback (DCLB) by the receiptof a DCLB-actuate sequence or DCLB-release sequence from the network or far-enddevice.

Disable – Ignores the DCLB-actuate and DCLB-release sequences for this port.

Enable – DCLB-actuate and DCLB-release sequences are recognized for this port.

Page 86: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-6 7985-A2-GB20-00October 1998

Table A-2. Synchronous Data Port Options (3 of 3)

Port (DTE) Initiated Loopbacks

Possible Settings: Disable, DTLB, DCLB, BothDefault Setting: Disable

Allows the initiation and termination of a local Data Terminal Loopback (DTLB) orremote Data Channel Loopback (DCLB) by the DTE connected to this port. (DTLB isequivalent to a V.54 loop 3, and DCLB is equivalent to a V.54 loop 2.) Control of theseloopbacks is through the DTE interchange circuits as specified by the V.54 standard.

Disable – Disables control of local DTLBs and remote DCLBs by the DTE connected tothis port.

DTLB – Gives control of the local DTLBs for this port to the DTE attached to this port.This loopback is controlled by the Local Loopback interchange circuit LL (CCITT 141).

DCLB – Gives control of the remote DCLBs for the far-end port connected to this port tothe DTE attached to this port. This loopback is controlled by the Remote Loopbackinterchange circuit RL (CCITT 140). The far-end equipment must support in-band V.54 loopbacks.

Both – Gives control of local DTLBs and remote DCLBs to the DTE connected to thisport.

Page 87: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-77985-A2-GB20-00 October 1998

System Options Menu

For System Options, refer to Table A-3. To access the System Options screen,follow this menu selection sequence:

Main Menu →Configuration →Load Configuration From →System

Table A-3. System Options

DSL Mode

Possible Settings: LTU, NTUDefault Setting: NTU

Controls whether the unit is configured as a control unit or tributary unit.

LTU – The unit is configured as a control unit (Line Termination Unit).

NTU – The unit is configured as a tributary unit (Network Termination Unit). This unit willrequest its IP address from the LTU during establishment of the PPP link.

NOTE: Changing this option will reset the card.

Test Timeout

Possible Settings: Enable , DisableDefault Setting: Enable

Allows user-initiated tests to end automatically. The feature should be enabled when theunit is remotely managed, so that control can be regained after a test is accidentallyexecuted.

Enable – User-initiated loopback and pattern tests end when test duration is reached.

Disable – Tests can be terminated manually from the Network Tests screen. Refer toRunning Network Tests in Chapter 5, Testing.

NOTE: Tests commanded by the DTE or network-initiated tests are not affected bythis test timeout.

Test Duration (min)

Possible Settings: 1–120Default Setting: 10

Number of minutes for a test to be active before automatically ending.� The Test Duration (min) option appears when Test Timeout is enabled.

1 to 120 – Amount of time in minutes for a user-initiated test to run before terminating.

Page 88: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-8 7985-A2-GB20-00October 1998

Communication Port

For Communication Port Options, refer to Table A-4. To access theCommunication Port screen, follow this menu selection sequence:

Main Menu →Configuration →Load Configuration From →CommunicationPort

Table A-4. Communication Port (1 of 3)

Port Use

Possible Settings: Terminal , Net LinkDefault Setting: Terminal

Specifies how the communications port is to be used.

Terminal – The communication port will be used for an Asynchronous terminalinterface.

Net Link – The communication port will be used as the network communication link toan IP network or device.

Port Type

Possible Settings: Asynchronous , SynchronousDefault Setting: Asynchronous

When Port Use is set to Net Link, Port Type controls whether the communication portwill be asynchronous or synchronous.

Asynchronous – Configures the communication port for asynchronous communication.

Synchronous – Configures the communication port for synchronous communication.

NOTE: Peer IP Address and Circuit Identifier are not copied.

Data Rate

Possible Settings: 9.6, 14.4, 19.2, 28.8, 38.4Default Setting: 9.6

Specifies the communication port baud rate.

9.6 – Communication port rate is 9600 bps.

14.4 – Communication port rate is 14400 bps.

19.2 – Communication port rate is 19200 bps.

28.8 – Communication port rate is 28800 bps.

38.4 – Communication port rate is 38400 bps.

Parity

Possible Settings: None , Odd, EvenDefault Setting: None

Specifies the parity of the communication port.

None – No parity used.

Odd – Odd parity used.

Even – Even parity used.

Page 89: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-97985-A2-GB20-00 October 1998

Table A-4. Communication Port (2 of 3)

Stop Bits

Possible Settings: 1, 1.5, 2Default Setting: 1

Specifies the number of stop bits for the communication port.

1 – One stop bit.

1.5 – One and one half stop bits.

2 – Two stop bits used.

Ignore Control Leads

Possible Settings: Disable, DTR Default Setting: Disable

Specifies whether DTR is used.

Disable – Control leads are treated as standard.

DTR – DTR is ignored.

Login Required

Possible Settings: Enable, DisableDefault Setting: Disable

Specifies if an ID and password are required to access the asynchronous terminalinterface on the communication port. Login IDs are created with a password and accesslevel. Refer to Chapter 7, Creating a Login.

Enable – Login ID and password are required to access the asynchronous terminalinterface.

Disable – No Login ID and password are required to access the asynchronous terminalinterface.

Port Access Level

Possible Settings: Administrator , OperatorDefault Setting: Administrator

Specifies the highest level of access allowed when accessing an ATI session through aTelnet session.

Administrator – This is the higher access level, permitting full control of the Model7985 Termination Unit. Access level is determined by the Login ID. If Telnet LoginRequired is disabled, the session access level is Administrator.

Operator – This is the lower access level, permitting read-only access to status andconfiguration screens.

Inactivity Timeout

Possible Settings: Enable, DisableDefault Setting: Disable

Provides automatic logoff of a Telnet session.

Enable – The Telnet session terminates automatically after the Disconnect Time.

Disable – A Telnet session will not be closed due to inactivity.

Page 90: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-10 7985-A2-GB20-00October 1998

Table A-4. Communication Port (3 of 3)

Disconnect Time (Minutes)

Possible Settings: 1 – 60Default Setting: 5

Number of minutes of inactivity before the session terminates automatically. Timeout isbased on no keyboard activity.

� Disconnect Time (minutes) option appears when Inactivity Timeout is enabled.

1 to 60 – The Telnet session is closed after the selected number of minutes.

Page 91: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-117985-A2-GB20-00 October 1998

Management and Communication Options Menu

The Management and Communication Options Menu includes the following:

� Telnet Sessions Options, Table A-5

� Communication Protocol Options, Table A-6

� SNMP Traps Options, Table A-7

Telnet Session Options

The Telnet Session Options (Table A-5) control whether a Telnet session isallowed through an interconnected IP Network. If allowed, these optionsdetermine what level of security to apply to the session to control access. Onlyone Telnet session is allowed at a time. Initial values are determined by theconfiguration you currently have loaded. To access the Telnet Session Optionsscreen, follow this menu selection sequence:

Main Menu →Configuration →Load Configuration From →Management and Communication →Telnet Session

Table A-5. Telnet Session Options (1 of 2)

Telnet Session

Possible Settings: Enable, DisableDefault Setting: Disable

Specifies if the Model 7985 Termination Unit will respond to a Telnet session requestfrom a Telnet client on an interconnected IP network.

Enable – Allows Telnet sessions between the unit and a Telnet client.

Disable – No Telnet sessions allowed.

Telnet Login Required

Possible Settings: Enable, DisableDefault Setting: Disable

Used to secure access to the ATI through a Telnet session. Login IDs are created with apassword and access level. Refer to Creating a Login in Chapter 7, Security.

Enable – Security is enabled. When access is attempted via Telnet, the user isprompted for a Login ID and password.

Disable – No Login required for a Telnet session.

Page 92: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-12 7985-A2-GB20-00October 1998

Table A-5. Telnet Session Options (2 of 2)

Session Access Level

Possible Settings: Administrator , OperatorDefault Setting: Administrator

The Telnet session access level is interrelated with the access level of the Login ID.Refer to ATI Access Levels in Chapter 7, Security for more information.

Administrator – This is the higher access level, permitting full control of the 7985Termination Unit. Access level is determined by the Login ID. If Telnet Login Required isdisabled, the session access level is Administrator.

Operator – This is the lower access level, permitting read-only access to status andconfiguration screens.

Inactivity Timeout

Possible Settings: Enable, DisableDefault Setting: Disable

Provides automatic logoff of a Telnet session.

Enable – The Telnet session terminates automatically after the Disconnect Time.

Disable – A Telnet session will not be closed due to inactivity.

Disconnect Time (Minutes)

Possible Settings: 1 – 60Default Setting: 5

Number of minutes of inactivity before a Telnet session terminates automatically. Timeout is based on no keyboard activity.

� Disconnect Time (minutes) option appears when Inactivity Timeout is enabled.

1 to 60 – The Telnet session is closed after the selected number of minutes.

Communication Protocol Options

To access the Communication Protocol Options screen, follow this menuselection sequence:

Main Menu →Configuration →Load Configuration From →Management and Communication →Comm Protocol Options

Table A-6. Communication Protocol Options (1 of 2)

Node IP Address

Possible Settings: 000.000.000.000 – 223.255.255.255Default Setting: 000.000.000.000

Specifies the Node IP address. This option is only available when the standalone unit isconfigured as an LTU.

000.000.000.000 – 223.255.255.255 – Enter an IP address for the node. The range forthe first byte is 000 to 223, with the exception of 127. The range for the remaining threebytes is 000 to 255.

Page 93: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-137985-A2-GB20-00 October 1998

Table A-6. Communication Protocol Options (2 of 2)

Node Subnet Mask

Possible Settings: 000.000.000.000 – 255.255.255.255Default Setting: 000.000.000.000

Specifies the Node Subnet Mask. This option is only available when the standalone unitis configured as an LTU.

000.000.000.000 – 255.255.255.255 – Enter an address for the Node Subnet Mask.

Default Network Destination

Possible Settings: None , COM, DSLDefault Setting: None

Specifies where the default management network is connected, for example, if yourdefault network is connected to the COM port, select COM as the default managementnetwork destination.

None – No default destination is defined. Unroutable data is discarded.

COM – The unit’s COM port is the default network destination. This option is onlyavailable when the Port Use option on the Communication Port Options menu is set toNet Link.

DSL – The unit’s DSL port is the default network destination.

Communication Port IP Address

Possible Settings: 000.000.000.000 – 223.255.255.255Default Setting: 000.000.000.000

Specifies the unit’s Communication Port IP Address when the unit is configured as anetwork communication link. This option is only used when the Port Use option on theCommunication Port Options menu is set to Net Link. If the COM Port IP address is notset (000.000.000.000) the node IP address specified by the Node IP Port will be used.

000.000.000.000 – 223.255.255.255 – Enter an address for the Communication Port.The range for the first byte is 000 to 223, with the exception of 127. The range for theremaining three bytes is 000 to 255.

Communication Port Subnet Mask

Possible Settings: 000.000.000.000 – 255.255.255.255Default Setting: 000.000.000.000

Specifies the unit’s Communication Port Subnet Mask when the unit is configured as anetwork communication link. This option is only used when the Port Use option on theCommunication Port Options menu is set to Net Link. If the COM Port IP address is notset (000.000.000.000), the node IP Address will be used.

000.000.000.000 – 255.255.255.255 – Enter an address for the Communication PortSubnet Mask.

Communication Port Link Protocol

Possible Settings: PPP, SLIPDefault Setting: PPP

Specifies the unit’s Communication Port link protocol when the unit is configured as anetwork communication link. This option is only used when the Port Use option on theCommunication Port Options menu is set to Net Link.

PPP – Defines Point-to-Point protocol for the link layer protocol for the networkcommunication link.

SLIP – Serial Line IP Protocol for the link layer protocol for the network communicationlink.

Page 94: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-14 7985-A2-GB20-00October 1998

SNMP Traps Options

To access the SNMP Traps Options screen, follow this menu selection sequence:

Main Menu →Configuration →Load Configuration From →Edit →Management and Communication →SNMP Traps

Table A-7. SNMP Traps Options (1 of 2)

SNMP Traps

Possible Settings: Enable, DisableDefault Setting: Disable

Controls the generation of SNMP trap messages. The options for addresses and typesof traps are located in this table.

Enable – SNMP trap messages are sent out to SNMP managers.

Disable – No SNMP trap messages are sent out.

Number of Trap Managers

Possible Settings: 1, 2, 3, 4, 5Default Setting: 1

Sets the number of SNMP management systems that will receive SNMP traps.

1 to 5 – Number of trap managers. An NMS IP address is required for each manager.

NMS n IP Address

Possible Settings: 000.000.000.000 – 223.255.255.255, ClearDefault Setting: 000.000.000.000

Specifies the Internet Protocol address used to identify each SNMP trap manager.

000.000.000.000 – 223.255.255.255 – Enter an address for each SNMP trap manager.The range for the first byte is 000 to 223, with the exception of 127. The range for theremaining three bytes is 000 to 255.

Clear – Clears the IP address and sets to all zeros.

NMS n Destination

Possible Settings: DSL, COMDefault Setting: DSL

Provides the network destination path of each trap manager.

DSL – The DSL port is the network destination path.

COM – The COM port is the network destination path.

General Traps

Possible Settings: Disable, Warm, AuthFail, BothDefault Setting: Both

Determines which SNMP traps are sent to each trap manager.

Disable – No general trap messages are sent.

Warm – Sends trap message for warmStart events.

AuthFail – Sends trap message for authenticationFailure events.

Both – Sends both trap messages.

NOTE: Refer to Appendix B, Standards Compliance for SNMP Traps.

Page 95: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-157985-A2-GB20-00 October 1998

Table A-7. SNMP Traps Options (2 of 2)

Enterprise Specific Traps

Possible Settings: Enable, DisableDefault Setting: Disable

Determines if SNMP traps are generated for enterprise-specific events.

Enable – SNMP traps are generated for enterpriseSpecific events.

NOTE: Refer to Enterprise Specific Traps in Appendix B, Standards Compliancefor SNMP Traps.

Disable – No enterprise-specific event traps are sent.

Link Traps

Possible Settings: Disable, Up, Down, BothDefault Setting: Both

Determines if SNMP traps are generated for link up and link down for one of thecommunication interfaces.

Disable – No linkUp or linkDown SNMP traps are generated.

Up – A linkUp trap is generated when the 7985 Termination Unit recognizes that one ofthe communication interfaces is operational.

Down – A linkDown trap is generated when the 7985 Termination Unit recognizes afailure in one of the communication interfaces.

Both – Sends trap messages for detection of both linkUp and linkDown.

NOTE: Refer to linkUp and linkDown in Appendix B, Standards Compliance forSNMP Traps.

Link Trap Interfaces

Possible Settings: Network, SYNC, AllDefault Setting: All

Determines if the SNMP linkUp, SNMP linkDown, and interface-relatedenterpriseSpecific traps are generated for the network interface and synchronous data(DTE) port, or all.

Network – SNMP trap messages are generated for the network interface.

SYNC – SNMP trap messages are generated for the synchronous data (DTE) port.

All – SNMP trap messages are generated for the network interface and thesynchronous data (DTE) ports.

Page 96: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Configuration Option Tables

A-16 7985-A2-GB20-00October 1998

This page intentionally left blank.

Page 97: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

B-17985-A2-GB20-00 October 1998

Standards Compliance forSNMP Traps

BSNMP Traps

This section describes the unit’s compliance with SNMP standards and anyspecial operational features for the SNMP traps supported. The unit supports thefollowing traps:

� warmStart

� authenticationFailure

� linkUp

� linkDown

warmStart

SNMP Trap Description Possible Cause

warmStart The unit has reinitializeditself.

The trap is sent after theunit resets and stabilizes.

There are novariable-bindings.

� Reset command.

� Power disruption.

authenticationFailure

SNMP Trap Description Possible Cause

authenticationFailure Failed attempts to accessthe unit.

There are novariable-bindings.

Three unsuccessful attemptswere made to enter a correctlogin/password combination.

Page 98: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Standards Compliance for SNMP Traps

B-2 7985-A2-GB20-00October 1998

linkUp and linkDown

The link SNMP traps are:

� linkUp – The unit recognizes that one of the communication interfaces isoperational.

� linkDown – The unit recognizes that one of the communication interfaces isnot operational.

The network and synchronous port interfaces (physical sublayer) are representedby an entry in the MIB-II interfaces table and supported by the DS1 MIB.

The following list describes the conditions that define linkUp and linkDown:

linkUp/Down Variable-Bindings

� ifIndex (RFC 1573)This object provides the index into the ifTable and potentially into tables in other MIBs.The values of ifIndex are the same for all models, although not all indexes aresupported for each model.The ifIndex included with the trap consists of:– 1 COM Port– 2 HDSL Interface, Port 1– 10 Synchronous Data Port, Port 1

� ifAdminStatus (RFC 1573)This object specifies the operational state of the interface:– up(1)

HDSL Network: DSL link is established.Synchronous Data Port: Port is enabled and both CTS and DSR are ON.

– down(2)HDSL Network: DSL link is not established.Synchronous Data Port: Port is disabled or CTS or DSR is OFF.

– testing(3)A test is active on the interface.

� ifOperStatus (RFC 1573)This object contains the same value as ifAdminStatus.

� ifType (RFC 1573)

This object is the type of interface:– propPointToPointSerial(22)

Used for the synchronous data port and EOC.– HDSL(96)

Used for the HDSL network interface.

Page 99: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Standards Compliance for SNMP Traps

B-37985-A2-GB20-00 October 1998

Enterprise-Specific Traps

The enterpriseSpecific trap indicates that an enterprise-specific event hasoccurred. The Specific-trap field identifies the particular trap that occurred. Thefollowing table lists the enterprise-specific traps supported by the unit:

SNMP Trap Description Possible Cause

enterpriseSelfTestFail(2) A hardware failure of theunit is detected during theunit’s self-test. The trap isgenerated after the unitcompletes initialization.

Failure of one or more of theunit’s hardwarecomponents.

enterpriseDeviceFail(3) An internal device failure. Operating software hasdetected an internal devicefailure.

enterpriseTestStart(5) A test is running. At least one test has beenstarted on an interface.

enterpriseConfigChange(6) The configuration changedvia the user interface. Thetrap is sent after 60 seconds have elapsedwithout another change.This suppresses thesending of numerous trapswhen multiple changes aremade in a short period oftime, as is typically thecase when changingconfiguration options.

Configuration has beenchanged via the ATI.

enterpriseTestStop(105) All tests have been halted. All tests have been haltedon an interface.

There are no variable-bindings for enterpriseDeviceFail andenterpriseConfigChange. The variable-binding for enterpriseSelfTestFail isdevSelfTestResults.

Page 100: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Standards Compliance for SNMP Traps

B-4 7985-A2-GB20-00October 1998

The tests that affect the enterpriseTestStart, enterpriseTestStop, and thevariable-bindings are different for each particular interface. Diagnostic tests areonly supported on the physical network and user data port interfaces. Thespecific tests and variable-bindings are described in the following table:

InterfaceenterpriseTestStart/StopVariable-Bindings Possible Cause

DSL Network � ifIndex (RFC 1573)

� ifAdminStatus (RFC 1573)

� ifOperStatus (RFC 1573)

� ifType (RFC 1573)

� ifTestType (RFC 1573)The following objects control testsin SNMP-managed devices:– noTest – Stops the test in

progress.– testLoopLLB – Initiates a Local

Loopback.– testLoopRLB – Initiates a

Remote Loopback.– testSendMon511 – Initiates a

Send and Monitor 511 test.– testSendLLBUp – Initiates an

LLB Up message to the remoteunit.

– testSendLLBDown – Initiates anLLB Down message to theremote unit.

� enterpriseTest Start – Anyone of the following tests isactive on the interface:– Line Loopback– Repeater Loopback– Remote Line Loopback– Send and Monitor 511

� enterpriseTest Stop – No testscurrently running on theinterface.

SynchronousData Ports

� ifIndex (RFC 1573)

� ifAdminStatus (RFC 1573)

� ifOperStatus (RFC 1573)

� ifTestType (RFC 1573)The following objects control testsin SNMP-managed devices:– noTest – Stops the test in

progress.– testLoopDCLB – Initiates a Data

Channel Loopback.– testLoopDTLB – Initiates a Data

Terminal Loopback– testSendDCLBUp – Initiates an

DCLB Up message to theremote unit.

– testSendDCLBDown – Initiatesan DCLB Down message to theremote unit.

� enterpriseTest Start – Anyone of the following tests isactive on the port:– Data Terminal Loopback– Data Channel Loopback– Remote Data Channel

Loopback

� enterpriseTest Stop – No testscurrently running on theinterface.

Page 101: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

C-17985-A2-GB20-00 October 1998

Cables and Pin Assignments

COverview

The following sections provide pin assignments:

� DSL Network Interface Cable

� COM Port Interface Cable

� EIA-530A Port Interface Connector

� EIA-530A to X.21 Interface Cable

� EIA-530A to RS 449 Interface Cable

� EIA-530A to V.35 Interface Cable

� Power Input Connector

� Optional Power Cable

Page 102: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Cables and Pin Assignments

C-2 7985-A2-GB20-00October 1998

DSL Network Interface Cable

The DSL line interface cable is a 20-foot, 24 AWG solid, 2-twisted-pair cable thatis RJ48C-to-RJ48C (Figure C-1).

Table C-1. DSL Network InterfaceConnector

Signal Pin Number

Ring 1

Tip 2

Ring 4

Tip 5

NOTE:A crossover cable (Pins 1, 2 to 4, 5) is required for connecting two Model 7985 Termination Units back-to-back.

98-15954a

Ring

Tip

Ring

Tip

Twisted Pair

Twisted Pair

RJ48CPlug

1

2

3

4

5

6

7

8

RJ48CPlug

1

2

3

4

5

6

7

8

Blue

White

Orange

White

Blue

White

Orange

White

Blue

White

Orange

White

Blue

White

Orange

White

Blue

White

Orange

White

Blue

White

Orange

White

Blue

White

Orange

White

Blue

White

Orange

White

Blue

White

Orange

White

Blue

White

Orange

White

Figure C-1. DSL Network Interface Cable with RJ48C Connector (Feature Number 7900-F1-514)

97-15884

8-PinPlug

Pin #1

Pin #8

Page 103: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Cables and Pin Assignments

C-37985-A2-GB20-00 October 1998

COM Port Interface Cable

The COM port connects to either a PC or to an ASCII terminal or printer foralarms. The COM port-to-PC cable is a 14-foot, 26 AWG, 8-conductor cable withan 8-position modular plug keyed connector and a DB9 socket connector (Figure C-2). The COM port connector is an 8-position keyed modular jack(Table C-2). The data signals on this port are referenced to a DTE interface.

Table C-2. COM Port InterfaceConnector

Signal Pin Number

Rx Data (out to DTE) 2

Ground 3

Tx Data (in from DTE) 4

DTR (in from DTE) 5

CD (out to DTE) 6

RTS (in from DTE) 7

Figure C-2. COM Port-to-PC Cable (Feature Number 7900-F1-510)

98-15886

Page 104: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Cables and Pin Assignments

C-4 7985-A2-GB20-00October 1998

EIA-530A Port Interface Connector

The EIA-530A Port interface connector information is shown in Table C-3.

Table C-3. EIA-530A Port Interface Connector

SignalCircuitMnemonic

CCITTNumber Direction Pin

Shield — — — 1

Signal Common AB 102A — 7

Signal Common AC 102B — 23

Transmitted Data BA 103 To DSU/CSU 2 (A)14 (B)

Received Data BB 104 From DSU/CSU 3 (A)16 (B)

Request-to-Send CA 105 To DSU/CSU 4 (A)19 (B)

Clear-to-Send CB 106 From DSU/CSU 5 (A)13 (B)

Received Line Signal Detector CF 109 From DSU/CSU 8 (A)10 (B)

DCE Ready CC 107 From DSU/CSU 6

DTE Ready CD 108/1, /2 To DSU/CSU 20

Transmit Signal Element Timing (DTE Source) DA 113 To DSU/CSU 11 (B)24 (A)

Transmit Signal Element Timing (DCE Source) DB 114 From DSU/CSU 12 (B)15 (A)

Receiver Signal Element Timing (DCE Source) DD 115 From DSU/CSU 17 (A)9 (B)

Local Loopback LL 141 To DSU/CSU 18

Remote Loopback RL 140 To DSU/CSU 21

Test Mode TM 142 From DSU/CSU 25

Page 105: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Cables and Pin Assignments

C-57985-A2-GB20-00 October 1998

EIA-530A-to-X.21 Interface Cable

The EIA-530A-to-X.21 adapter cable (Figure C-3) provides the X.21 interfaceshown in Table C-4.

98-15883

2

14

3

16

17

9

4

19

8

10

7

24

11

2

9

4

11

6

13

3

10

5

12

8

7

14

TD-A

TD-B

RD-A

RD-B

RXC-A

RXC-B

RTS-A

RTS-B

RLSD-A

RLSD-B

SIG. COMMON

TT-A

TT-B

TD-A

TD-B

RD-A

RD-B

RXC-A

RXC-B

RTS-A

RTS-B

RLSD-A

RLSD-B

SIG. COMMON

TT-A

TT-B

530 SIGNAL

DB25PLUG

DB15SOCKET

X.21 SIGNAL

495-14787

Figure C-3. EIA-530A-to-X.21 (Cable Feature Number 7900-F1-505)

Page 106: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Cables and Pin Assignments

C-6 7985-A2-GB20-00October 1998

Table C-4. X.21 Cable Interface

SignalCCITTNumber Direction Pin

Signal Common 102 — 8

Transmitted Data 103 To DSU/CSU 2 (A)9 (B)

Received Data 104 From DSU/CSU 4 (A)11 (B)

Request-to-Send 105 To DSU/CSU 3 (A)10 (B)

Data Channel Received Line Signal Detector 109 From DSU/CSU 5 (A)12 (B)

Transmit Signal Element Timing (DTE Source) 113 To DSU/CSU 7 (A)14 (B)

Receiver Signal Element Timing (DCE Source) 115 From DSU/CSU 6 (A)13 (B)

Page 107: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Cables and Pin Assignments

C-77985-A2-GB20-00 October 1998

EIA-530A-to-RS449 Cable Interface

The EIA-530A-to-RS449 adapter cable (Figure C-4) provides the RS449 interfaceshown in Table C-5.

98-15902

1

2

14

3

16

15

12

17

9

4

19

5

13

20

8

10

6

7

21

18

23

24

11

25

22

1

4

22

6

24

5

23

8

26

7

25

9

27

12

13

31

11

19

14

10

20

17

35

18

29

30

SHIELD

TD-A

TD-B

RD-A

RD-B

TXC-A

TXC-B

RXC-A

RXC-B

RTS-A

RTS-B

CTS-A

CTS-B

DTR

RLSD-A

RLSD-B

DSR

SIG. COMMON

RL

LL

RCV. COMMON

TT-A

TT-B

TM

SIG. COMMON

SHIELD

TD-A

TD-B

RD-A

RD-B

TXC-A

TXC-B

RXC-A

RXC-B

RTS-A

RTS-B

CTS-A

CTS-B

DTR-A

RR-A

RR-B

DM-A

SIG. COMMON

RL

LL

RCV. COMMON

TT-A

TT-B

TM

DM-B

DTR-B

530 SIGNAL

DB25PLUG

DB37SOCKET

449 SIGNAL

495-14323-01

Figure C-4. EIA-530A-to-RS449 Cable Pinouts (Feature Number 7900-F1-504)

Page 108: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Cables and Pin Assignments

C-8 7985-A2-GB20-00October 1998

Table C-5. RS449 Cable Interface

SignalCircuitMnemonic

CCITTNumber Direction Pin

Shield — — — 1

Signal Ground SG 102A — 19

Receive Ground RC 102B — 20

Send Common SC — — 37

Send Data SD 103 To DSU/CSU 4 (A)22 (B)

Receive Data RD 104 From DSU/CSU 6 (A)24 (B)

Request-to-Send RS 105 To DSU/CSU 7 (A)25 (B)

Clear-to-Send CS 106 From DSU/CSU 9 (A)27 (B)

Receiver Ready RR 109 From DSU/CSU 13 (A)31 (B)

Data Mode DM 107 From DSU/CSU 11 (A)29 (B)

Terminal Ready TR 108/1, /2 To DSU/CSU 12 (A)30 (B)

Terminal Timing TT 113 To DSU/CSU 17 (A)35 (B)

Send Timing ST 114 From DSU/CSU 5 (A)23 (B)

Receive Timing RT 115 From DSU/CSU 8 (A)26 (B)

Local Loopback LL 141 To DSU/CSU 10

Remote Loopback RL 140 To DSU/CSU 14

Test Mode TM 142 From DSU/CSU 18

Page 109: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Cables and Pin Assignments

C-97985-A2-GB20-00 October 1998

EIA-530A-to-V.35 Cable Interface

The EIA-530A-to-V.35 adapter cable (Figure C-5) provides the V.35 interfaceshown in Table C-6.

98-15885

Pin 1

MM

A

B

NN

1

2

14

3

16

15

12

17

9

4

5

8

6

7

24

11

20

21

18

25

23

A

P

S

R

T

Y

AA

V

X

C

D

F

E

B

U

W

H

N

L

NN

SHIELD

TD-A

TD-B

RD-A

RD-B

TXC-A

TXC-B

RXC-A

RXC-B

RTS

CTS

RLSD

DSR

SIG. COMMON

TT-A

TT-B

DTR

RL

LL

TM

SIG. COMMON

SHIELD

TD-A

TD-B

RD-A

RD-B

TXC-A

TXC-B

RXC-A

RXC-B

RTS

CTS

RLSD

DSR

SIG. COMMON

TT-A

TT-B

DTR

RL

LL

TM

530 SIGNAL

DB25PLUG

MS34SOCKET

V.35SIGNAL

497-15233

Figure C-5. EIA-530A-to-V.35 Cable Pinouts (Feature Number 7900-F1-503)

Page 110: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Cables and Pin Assignments

C-10 7985-A2-GB20-00October 1998

Table C-6. V.35 Cable Interface

SignalCCITTNumber Direction Pin

Shield — — A

Signal Common 102 — B

Transmitted Data 103 To DSU/CSU P (A)S (B)

Received Data 104 From DSU/CSU R (A)T (B)

Request to Send 105 To DSU/CSU C

Clear to Send 106 From DSU/CSU D

Data Channel Received Line Signal Detector 109 From DSU/CSU F

Data Set Ready 107 From DSU/CSU E

Data Terminal Ready 108/1, /2 To DSU/CSU H

Transmit Signal Element Timing (DTESource)

113 To DSU/CSU U (A)W (B)

Transmit Signal Element Timing (DCESource)

114 From DSU/CSU Y (A)AA (B)

Receiver Signal Element Timing (DCESource)

115 From DSU/CSU V (A)X (B)

Local Loopback 141 To DSU/CSU L

Loopback/Maintenance 140 To DSU/CSU N

Test Indicator 142 From DSU/CSU NN

Page 111: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Cables and Pin Assignments

C-117985-A2-GB20-00 October 1998

Power Input Connector

The required input power connector leads are shown in Table C-7.

Table C-7. DC Power Connector

Signal Pin Number

+24 Vdc 5

+24 Vdc Return 4

Chassis Ground 3

Optional Power Cable

The optional power cable is a 14.5-foot, 18 AWG stranded cable. The connectoris terminated at one end with a 6-position Molex 39-01-2060 connector. The otherend of the cable is terminated with a bare wire that should be connected to a DCpower source. Figure C-6 shows the wire colors.

1

2

3

4

5

6

X

X

Earth Ground

RTN

+24 Vdc

X

Black

Red

Green

White

Orange

Blue

98-14158-01

Figure C-6. DC Power Cable (Feature Number 7900-F1-506)

PIN 1

PIN 6

98-16138

Page 112: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Cables and Pin Assignments

C-12 7985-A2-GB20-00October 1998

This page intentionally left blank.

Page 113: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

D-17985-A2-GB20-00 October 1998

Technical Specifications

DSpecifications Criteria*

Size Width 7.25 inches (18.4 cm)

Height 1.5 inches (3.8 cm)

Length 9.4 inch (24.9 cm)

Weight Approximately 1.25 lbs. (0.6 kg)

Approvals

Safety Certifications Refer to the equipment’s label for approvals on product.

Power The Model 7985 Termination Unit contains a DC-to-DCconverter that requires +24V power input. The +24Vpower is distributed through a universal power supplysupplied with the unit.

Maximum Power Dissipation = 6 watts

Cables and Cable Guide Feature Number Description

7900-F1-503 EIA-530A to V.35 Interface Cable

7900-F1-504 EIA-530A to X.21 Interface Cable

7900-F1-505 EIA-530A to RS 449 Interface Cable

7900-F1-506 Optional Power Cable

7900-F1-507 COM Port Interface Cable

7900-F1-514 DSL Network Interface Cable

Physical Environment

Operating temperature

Storage temperature

Relative humidity

Shock and vibration

32° to 122° F (0° to 50° C)

–4° F (–20° C) to 158° F (70° C)

5% to 85% (noncondensing)

Withstands normal shipping and handling.

* Technical specifications are subject to change without notice.

Page 114: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Technical Specifications

D-2 7985-A2-GB20-00October 1998

This page intentionally left blank.

Page 115: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

GL-17985-A2-GB20-00 October 1998

Glossary

A random bit test 511 bytes in length.

Alternate Mark Inversion. A line coding technique used to accommodate the ones densityrequirements of E1 or T1 lines.

Asynchronous Terminal Interface. A menu-driven, VT100-compatible system forconfiguring and managing the termination unit.

Bipolar Violation. In a bipolar signal, a one (mark, pulse) which has the same polarity as itspredecessor.

Any part of the local loop that is not in the direct talking path between the CO and theservice user.

Carrier Detect. The received line signal detector. V.24 circuit 109.

Central Office/Central Site. The PSTN facility that houses one or more switches servinglocal telephone subscribers.

Communications port. A computer’s serial communications port used to transmit to andreceive data from a modem. The modem connects directly to this port.

Customer Premises.

Customer Premises Equipment. Terminal equipment on the service user’s side of thetelecommunications network interface.

Central Processing Unit. The main or only computing device in a data processing system.

Cyclic Redundancy Check. A mathematical method of confirming the integrity of receiveddigital data.

Clear To Send. A signal indicating that the device is ready for the DTE to transmit data.Usually occurs in response to Request To Send (RTS).

Code Violation. Detected when using HDB3 coding format, this is equivalent to a BPVwhen using AMI coding.

Data Communications Equipment. The equipment that provides the functions required toestablish, maintain, and end a connection. It also provides the signal conversion requiredfor communication between the DTE and the network.

Data Channel LoopBack. Loops the data received from the network interface, for all DS0channels allocated to the selected port, back to the network.

Digital Subscriber Line. The non-loaded, local-loop copper connection between thecustomer and the first node within the network.

Digital Subscriber Line Access Multiplexer. A platform for DSL modems that provideshigh-speed data transmission over traditional twisted-pair wiring.

Data Set Ready. A signal from the modem to the DTE that indicates the modem is turnedON and connected to the DTE.

Data Terminal Equipment. The equipment, such as a computer or terminal, that providesdata in the form of digital signals for transmission.

511

AMI

ATI

BPV

bridged tap

CD

CO

COM port

CP

CPE

CPU

CRC

CTS

CV

DCE

DCLB

DSL

DSLAM

DSR

DTE

Page 116: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Glossary

GL-2 7985-A2-GB20-00October 1998

Data Terminal LoopBack. Loopback mode that loops the data for a particular synchronousdata port back to the port just before it is combined with the rest of the T1 data stream.

Data Terminal Ready. A signal from the DTE to the modem, sent via Pin 20 of theEIA-232 interface (V.24 circuit 108/1, /2), that indicates the DTE is turned ON andconnected to the modem.

A wideband digital interface operating at 2.048 Mbps, defined by ITU recommendationsG.703 and G.704. It is used primarily outside North America.

Excessive Error Rate. An error rate that is greater than the threshold that has beenconfigured in the device.

Embedded Operations Channel. An in-band channel between DSL devices, used for 4 kbps management data.

Errored Seconds. A second with one or more ESF error events (one or more CRC6 errorevents or OOFs).

Extended SuperFrame. The T1 transmission standard that specifies 24 frames as anextended superframe to be used for frame synchronization and to locate signaling bits.

A type of network that supports high-speed communication among systems. It is a widelyimplemented standard for LANs. All hosts are connected to a coaxial cable where theycontend for network access using a Carrier Sense, Multiple Access with CollisionDetection (CSMA/CD) paradigm.

European Telecommunications Standardization Institute. An organization that producestechnical standards in the area of telecommunications.

A predetermined set of configuration options containing the optimum settings for operationon asynchronous dial networks.

Frame Alignment Signal. A loss of signal (LOS) error detection.

Frame Alignment Word. A loss of synchronization error detection.

Federal Communications Commission. The Board of Commissioners that regulates allelectrical communications that originate in the United States.

Far-End Block Error. Block errors reported by remote equipment.

A high-speed connection-oriented packet switching WAN protocol using variable-lengthframes.

File Transfer Protocol. A TCP/IP standard protocol that allows a user on one host toaccess and transfer files to and from another host over a network, provided that the clientsupplies a login identifier and password to the server.

An ITU recommendation for the physical and logical characteristics of hierarchical digitaldevices.

An ITU recommendation for synchronous frame structures.

High Density Bipolar Three Zeros Substitution. A line coding technique used toaccommodate the ones density requirements of E1 lines.

High-bit-rate Digital Subscriber Line. A technique for high bandwidth, bidirectionaltransmission over copper wire for T1 and E1 services.

Internet Protocol. An open networking protocol used for internet packet delivery.

Internet Protocol address. The address assigned to an internet host.

Kilobits per second. One kilobit is usually taken to be 1,024 bits.

DTLB

DTR

E1

EER

EOC

ES

ESF

Ethernet

ETSI

factory defaults

FAS

FAW

FCC

FEBE

frame relay

FTP

G.703

G.704

HDB3

HDSL

IP

IP address

kbps

Page 117: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Glossary

GL-37985-A2-GB20-00 October 1998

Local Area Network. A privately owned and administered data communications networklimited to a small geographic area.

Light Emitting Diode. A light or status indicator that glows in response to the presence of acertain condition (e.g., an alarm).

Line LoopBack. A test in which the received signal on the network interface is looped backto the network without change.

A diagnostic procedure that sends a test message back to its origination point. Used totest various portions of a data link in order to isolate an equipment or data line problem.

Loss of Signal. The T1 line condition where there are no pulses.

Line Termination Unit. The control unit on the network end of a link. (The NTU is on thecustomer premises end.)

Megabits per second. One megabit is 1,048,576 (10242) bits.

Management Communications Controller. The DSLAM circuit card used to configure andmonitor the DSLAM.

Management Information Base. A database of managed objects used by SNMP to providenetwork management information and device control.

MIB Release 2. The current Internet-standard MIB, defined by RFC 1213.

Multirate SDSL.

Mobile Telephone Switching Office. A generic name for the main cellular switching centerwhich supports multiple base stations.

Network Management System. A computer system used for monitoring and controllingnetwork devices.

Network Termination Unit. The unit on the customer premises end of a link. (The LTU is onthe network end.)

Out Of Frame. An error condition in which frame synchronization bits are in error.

A reinitialization of the device that occurs at power-up or in response to a reset command.

Repeater LoopBack. Loops the signal being sent to the network back to the DTEDrop/Insert and data ports after it has passed through the framing circuitry of the device.

A device that connects LANs by dynamically routing data according to destination andavailable routes.

Request to Send. A signal from the DTE to the device, indicating that the DTE has data tosend. V.24 circuit 105.

Received Data. Pin 3 of the EIA-232 interface that is used by the DTE to receive data fromthe modem. Conversely, the modem uses Pin 3 to transmit data to the DTE.

Symmetrical Digital Subscriber Line. A technique for the use of an existing twisted pair linethat permits high bandwidth, bidirectional transmission.

Severely Errored Seconds. Usually defined as a second during which a specific number ofCRC errors was exceeded, or an OOF or other critical error occurred.

Simple Network Management Protocol. Protocol for open networking management.

Transmission Control Protocol/Internet Protocol. The dominant protocol suite in theworldwide Internet, TCP allows a process on one machine to send data to a process onanother machine using the IP. TCP can be used as a full-duplex or one-way simplexconnection.

LAN

LED

LLB

loopbackloopback

LOS

LTU

Mbps

MCC

MIB

MIB II

M/SDSL

MTSO

NMS

NTU

OOF

reset

RLB

router

RTS

RXD

SDSL

SES

SNMP

TCP/IP

Page 118: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Glossary

GL-4 7985-A2-GB20-00October 1998

Virtual terminal protocol in the Internet suite of protocols. Allows the user of one hostcomputer to log into a remote host computer and interact as a normal terminal user for thathost.

Trivial File Transfer Protocol. A standard TCP/IP protocol that allows simple file transfer toand from a remote system without directory or file listing. TFTP is used where FTP is notavailable.

Transmit Data. Pin 2 of the EIA-232 interface that is used by the DTE to transmit data tothe modem. Conversely, the modem uses Pin 2 to receive data from the DTE.

An operating system developed at AT&T Bell Laboratories and since used as the basis ofsimilar operating systems.

An ITU-T standard for a high-speed, 34-position, DCE/DTE interface.

Wide Area Network. A network that spans a large geographic area.

Telnet

TFTP

TXD

UNIX

V.35

WAN

Page 119: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

IN-17985-A2-GB20-00 October 1998

Index

AAbort All Tests, 5-1ac transformer, connecting, 3-2access

SNMP, 1-3to async terminal interface, 2-3

access leveleffective, 7-1functions available for, 7-1

access to user interface, resetting/restoring, 7-4Action on Network LOS Alarm, A-5administer login, 7-2Alarm, LED, 4-10ASCII, printable characters, 3-4ATI (Asynchronous Terminal Interface)

access, 2-1defined, 1-2exiting, 2-9initiating session, 2-2virtual function keys, 2-7

authentificationFailure, B-1AutoRate, 3-13, A-2

CCables

COM Port Interface Cable, C-3DSL Network Interface Cable, C-2EIA-530A-to-RS449 Cable Interface, C-7EIA-530A-to-X.21 Interface Cable, C-5Optional Power Cable, C-11

cables, C-1figures, C-1part numbers, D-1pin Assignments, C-1

cablingCOM Port-to-PC cable, C-3DC Power cable, C-11DSL Network Interface Cable, C-2

Card Failedself-test result, 4-4status message, 4-3

Circuit Identifier, A-3clocking, A-4COM port, resetting, 7-4COM port settings, 3-3Communication Port, A-8Configurating AutoRate, 3-13Configuring the unit, 3-1configuration

example, 1-3option tables, A-1

configuration changes, saving, 3-16Configuration Edit/Display, 3-12Configuration Loader, 3-14Configuration menu, 3-11Configuration Mode, choosing an interface mode, 3-5Configuration Options, accessing, 3-11configuration options

Communication Port, A-8SYNC Ports, A-4System Options, A-7

Connecting to the Network, 3-3connectors

EIA-530A Port, C-4Location, 1-4power input, C-11rear panel, C-1

CPU Fail, self-test result, 4-4create login ID, 7-2customer configuration, 3-5

switchpacks, internal switches, 3-6

Page 120: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Index

IN-2 7985-A2-GB20-00October 1998

Ddata channel loopback (DCLB), 5-9, A-6data port loopbacks, DTE initiated, A-6data port tests, 5-7data terminal loopback (DTLB), 5-8, A-6dc power option, 3-2default configuration area, 3-5delete, Login ID, 7-4device, messages, 6-3– 6-4dimensions, D-1Disconnect Time, for Telnet session, A-10, A-12documents, related, viDOS, TFTP server on, 3-15download code, 3-17Download Failed, status message, 4-4DSL Line Rate, 3-10

Fixed Rate, 3-14DSL Port, LEDs, 4-10DSLAM, defined, 1-2DTE port tests, 5-7DTE-initiated loopbacks, A-6

EEER (Excessive Error Rate) , status message, 4-3effective access level, 7-1EIA-530A Port Interface Connector, C-4EIA-530A-to-V.35 Cable Interface, C-9ending an ATI session, 2-9enterprise, SNMP traps, B-3environment requirements, D-1error messages, line 24, 6-3error statistics, 4-6ESD precautions, 3-6Excessive Error Rate (EER) Threshold, A-2

Ffactory default configuration options, resetting, 7-4factory defaults, 3-5Failure, self-test result, 4-4feature numbers, D-1features, 1-2firmware, download from server, 3-17

Hhealth and status messages, 4-3

Iidentity, 3-4inactivity timeout, for Telnet session, A-9, A-12Initial Startup and Configuration, 3-1intended audience, vInternal Switches, 3-6Manual configuration, Internal Switches, 3-6invert transmit clock, A-5IP address, DSL peer, A-3IP addresses, 8-1IP addressing, example, 8-2

Kkeyboard functions, 2-6

Llamp test, 5-11LEDs, 4-9, 4-10Link Up, LEDs, 4-10link-layer protocols, 8-1linkUp and linkDown traps, B-2local line loopback (LLB), 5-3Login ID

access levels, 7-1adding, 7-2deleting, 7-4

login ID, 7-1loopback, effect on LEDs, 4-10LOS (Loss Of Signal), status message, 4-3LOS alarm action, A-5

Mmain menu, 2-2, A-1Management and Communication Options, A-11management port

access, 7-1settings, 2-1

Margin Threshold, A-2Memory Fail, status, 4-4messages

alarm and device, 6-1health and status, 4-3line 24, 6-3self-test results, 4-4test status, 4-5

MIB, support, 1-5monitoring, 4-1

Page 121: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Index

IN-37985-A2-GB20-00 October 1998

Nnavigating the screens, 2-6Net Margin Threshold, status message, 4-3network

interface options, A-2tests, 5-2

Network DSL Failed, self-test result, 4-4network interface, pin assignments, C-2– C-12network interface options, A-2Network-Initiated DCLB, A-5NMS, SNMP connectivity, 8-1no test active status message, 4-5

OOK, LED, 4-10OOF (Out Of Frame), status message, 4-3options, configuration tables, A-1overview

Termination Unit, 1-2user’s guide, v

Ppart numbers, D-1Passed, self-test result, 4-4Payload Rate, A-4PC

connecting, 3-3requirements, 3-3

Peer IP Address, A-3performance statistics, 4-8physical environment requirements, D-1pin assignments, C-1port, COM, C-3Port Status, A-4power cord installation, 3-2power requirements, D-1power supply

ac transformer, 3-2optional dc, 3-2– 3-18

RRear Panel, 1-4related documents, viremote send line loopback, 5-5repeater loopback (RLB), 5-4resetting

the access unit, COM port, 7-4the unit, default configuration options, 7-4

restoring, user interface access, 7-4RS-449 interface, C-8

SSave Configuration screen, 3-16saving option changes, 3-16screen, function keys, 2-7screens, for user interface, 2-1– 2-6SDSL Mode, A-7security, 7-1Selectable Payload Rates, 3-9self-test results, 4-4Send and Monitor 511, 5-6Send Ones configuration option, A-5Send Remote DCLB Loopback, 5-10size of unit, D-1SNMP

trap options, 6-2traps, B-1

start-up, ATI, 2-1status, test messages, 4-5subnet, IP addresses, 8-1Switchpack definitions, 3-8Switchpack locations, 3-7Switchpack S1 Definitions, 3-8Switchpack S2 Definitions, 3-10SYNC Data Port Tests, 5-7Sync Port, LEDs, 4-10SYNC Ports Options, A-4SYNC Pt Down, status message, 4-3SYNC Pt Failed, self-test result, 4-4system, LEDs, 4-10System Options, A-7

Page 122: HOTWIRE MODEL 7985 M/HDSL STANDALONE TERMINATION UNIT WITH ...support.dasanzhone.com/support/manuals/docs/79/7985-A2-GB20-00.pdf · Hotwire Model 7985 Multirate/High-bit-rate Digital

Index

IN-4 7985-A2-GB20-00October 1998

TTelnet session

access level, A-12, A-13enable/disable, A-11, A-12inactivity timeout, A-9, A-12login required, A-11, A-13

telnet session access, 7-1telnet session options, A-11, A-12terminal

communication parameters, 3-3connecting, 3-3

terminal port, direct connection, 2-1test

aborting, 5-12Data Channel Loopback, 5-9Data Terminal Loopback, 5-8LED, 4-10Line Loopback, 5-3Network-Initiated DCLB, A-5Port (DTE) Initiated Loopbacks, A-6Remote Send Line Loopback, 5-5Repeater Loopback, 5-4Send and Monitor 511, 5-6status messages, 4-5SYNC Data Port, 5-7terminating, 5-12Test Duration, A-7Test Timeout, A-7

Test menu, 5-2testing, 5-1timeout

Com port session inactivity, A-9Telnet session inactivity, A-12

transmit clock inversion, A-5transmit clock source, A-4traps, SNMP, 6-2, B-1troubleshooting, 6-5

error statistics, 4-6performance statistics, 4-8

UUNIX, TFTP server on, 3-15user interface, 1-3, 3-3

async terminal, 2-1how to access, 2-1resetting/restoring access, 7-4

VV.35 interface, C-10V.54 Loop 3. See data terminal loopback (DTLB)virtual function keys, 2-7

WwarmStart, B-1weight of unit, D-1