HiQ Equipment catalog
Transcript of HiQ Equipment catalog
HiQ®. Specialty gas program.
Equipment & gasdistribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
origami [origami] (jap., from ori ’folding' and kami 'paper'), the art of folding paper to create figures and artistic decoration.
Existed in Japan already at the 9’Th century, when paper become a common material. Figures can be all from very simple to artistic and
complex. They have been used both in ceremonies and as toys, pedagogical examples, wrappings, lamp screens, etc.
Source: Encyclopedia Britannica
Equipment & gas distribution systems.HiQ® equipment and gases
Contact your Linde local sales representative for
ordering any of the specialty gas catalogues:
• Automotive• Biotech, chemical, petrochemical
& pharmaceutical• Indoor & outdoor environment• Manufacturing
For more information about the HiQ® Specialty
Gas products, equipment and services program
from Linde, please visit our homepage at:
http://HiQ.Linde-Gas.com
You will find this site most useful in your every-
day work with specialty gases. Apart from the
complete program of Specialty Gas products and
equipment from Linde we have also included ex-
tensive information and supporting on-line
tools.
® ACCURA is a registered trademark of the Linde Group.
® HiQ REDLINE is a registered trademark of the Linde Group.
™ BASELINE is a trademark of the Linde Group.
® ECOCYL is a registered trademark of the Linde Group.
® HiQ is a registered trademark of the Linde Group.
™ Linde minican is a trademark of the Linde Group.
™ SECCURA is a trademark of the Linde Group.
® BUNA is a registered trademark of Bayer AG.
™ CleanLine is a trademark of BROEN A/S.
® ELGILOY is a registered trademark of Elgiloy Limited Partnership.
® HASTELLOY is a registered trademark of Haynes International, Inc.
® HOGEN is a registered trademark of Distributed Energy Systems Corp.
™ IntelliSwitch is a trademark of CONCOA.
® KALREZ is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
® KEL-F is a registered trademark of 3M.
® MONEL is a registered trademark of Inco Alloys International.
® Nanochem is a registered trademark of Matheson Tri-Gas, Inc.
® NEOPRENE is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
® NITRONIC is a registered tradename of Armco, Inc.
® NYLON is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
® SIMRIZ is a registered trademark of Freudenberg-NOK.
™ STABLEFLOW is a trademark of Distributed Energy Systems Corp.
® SWAGELOK is a registered trademark of Swagelok Company.
® TEFLON is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
® VCR is a registered trademark of Swagelok Company.
® VESPEL is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
® VITON is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Preface 5
Central gas supply 9
HiQ® REDLINE Gas panels 15
HiQ® REDLINE Points of use 53
HiQ® REDLINE Cylinder regulators 63
The right HiQ® REDLINE choice 72
CleanLine™ 79
Quick Connect 89
BASELINE™ 101
Components 111
Special equipment 137
IntelliSwitch™ – Automatic gas management system 138
STABLEFLOW™ HCS – Hydrogen control system 140
Ultra high pressure cylinder regulator 142
High flow regulator for corrosive gases 144
Low flow cylinder regulator 146
Mini cylinder regulator 148
Safety solutions 151
Standard cabinets 152
2-valve purge gas panel 154
3-valve process gas panel 156
5-valve process gas panel 158
Operation monitor 160
Fully automatic 162
Containers 165
HiQ® specialty gas generators 171
Portable gas solutions 197
Cylinder types 203
Equipment connections, tubings and fittings 209
Inlet connections 210
Outlet connections 214
Fittings 215
Tubings 215
Accessories 217
Centralized monitoring systems 218
Contact gauges & Pressure transducers 220
Mounting bracket 222
Wall mounting bracket & gas cylinder trolley 224
HiQ® Gas Supply System Installations 227
Services 231
Physical data 237
Conversion tables 250
Material compatibility 252
Index 255
Table of contents.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Preface.
In order to simplify everyday work, Lindehas created the HiQ® Specialty Gas productprogram. This contains different sections fordifferent industrial areas, to focus theamount of information and concentrate on
routine use. Also, it is intended to meet theincreasing demands on quality and newapplications. This section deals with thehardware need for gas distribution rangingfrom cylinders to large gas installations.
HiQ® Specialty gas program.Equipment & gas distribution systems.
One of the most critical points when using gas
for analysis and high tech production, is to
maintain the integrity of the gas between cylin-
der and instrument or reactor. The quality of the
gas is often not better than the quality of the
distribution system. Therefore, it is very impor-
tant to design and plan the gas supply system
carefully.
The equipment in this catalog is divided in dif-
ferent series, the HiQ® REDLINE portfolio, the
CleanLine™ points of use and the Quick Con-
nect points of use for laboratory use, and the
BASELINE™ regulators for use in chemical appli-
cations that use gases of lower purity. At the
end of this catalog are some useful checklists
for when planning and carrying through central
gas supply system installations.
• If nothing else is stated the pressure is gauge
pressure at STP (Standard Temperature and
Pressure; 273.15 K and 101,325 Pa).
• n.a. stands for not applicable, e.g., pressure
rating for a point of use that does not contain
any pressure restricting components.
• Linde reserve the right to make alterations to
specifications, quantities, etc., for production
or other reason, subsequent to publication.
• The information contained herein has been
prepared by qualified experts within Linde.
While we believe that the information is
General symbols
Group green central gas supply system equipment for inert and non-reactive
gases used as carrier gas or likewise, where gas integrity is non-crucial at
cylinder change.
Group blue central gas supply system equipment, with own gas purge, for
inert and nonreactive gases and gas mixtures where gas integrity is important
at cylinder change.
Group orange central gas supply system equipment, with purge gas (nitrogen
or likewise) purging, for toxic and reactive gases and gas mixtures, where gas
integrity and safety is important at cylinder change.
Preface.
HiQ® Specialty gas program.Equipment & gas distribution systems.
accurate within the limits of the analytical
methods employed and is complete to the
extent of the specific analyses performed,
we make no warranty or representation as
to the suitability of the use of the information
for any particular purposes. The information
is offered with the understanding that any
use of the information is at the sole discretion
and risk of the user. In any case Linde’s
liability arising out of the use of the informa-
tion contained herein shall be limited by the
fee established for providing such informa-
tion.
• The HiQ® codes work like this; A full code is
10 digits long (xxxxyyyzzz). For Hardware the
first four defines the Equipment (xxxx), the
following three the Equipment Outlet (yyy)
and the last three the Equipment Inlet (zzz).
When Outlet and/or Inlet are undefined these
are zeros (000). For gases the first four digits
define the Gas product (xxxx), the following
three the Cylinder (yyy) and the last three
the Cylinder Valve (zzz). Equipment matching
a specific gas shall have the same three last
figures (zzz) where Cylinder Valve connection
and Equipment Inlet connection follow the
same standard.
Ar 10 bar
∆pN2 = 0 bar(a)
∆pN2 = 0.78 bar(a)
The driving force in diffusion is the difference in
concentration, here expressed as partial pressures.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Central gas supply.The system that gives you controlover the gas supply.
Due to their special properties, specialty gases place particular demands on components fordistribution, control and monitoring. Either because the applications require that the gasesshall maintain their high purity throughout the point of use, or because their chemical andphysical properties require special design of the central gas supply system.
HiQ® Specialty gas program.Equipment & gas distribution systems.
The advantages of a HiQ® REDLINE central gas
supply system are among others these:
Increased safety• The risk of accidents is reduced, as there is no
need to handle gas cylinders inside the work
place. Only low-pressure equipment and small
gas quantities are present in the work place.
• Gas cylinders are collected under one roof,
which facilitates removal from labs and work
areas.
• The handling of high-pressure cylinders and
the connection of toxic gases should be car-
ried out by trained staff. If a problem with
leaking gas should occur, ventilation is essen-
tial. This is especially important while han-
dling inflammable and toxic gases, and is
simplified by the central approach.
Improved operating economy• A continuous gas supply to each work station
means less wasted time and fewer unplanned
disruptions for changing gas cylinders.
• Fewer and larger gas cylinders which together
supply all users, means more effective empty-
ing of the cylinders which in turn give lower
costs for gas and cylinder rental as well as
transport charges. In addition the store moni-
toring and purchasing can be centralized and
rationalized.
Better working environment• The work place can be designed more appro-
priately.
• Heavy gas cylinders containing toxic gases
under high pressure can involve great risks.
• Outlets positioned at every work station are
convenient and easy to use.
Turnkey deliveries• Together with the customer we carry out a re-
quirement analysis. Thereafter, planning and
installation takes place.
• A service agreement guarantees a trouble-
free gas supply without unplanned operating
stoppages.
Quality requirements govern the choice ofmaterialThe gas to be distributed and the level of con-
tamination that can be accepted in the gas de-
termine the choice of component material in a
gas supply system. The inner surface finish of
components is of great importance to the final
purity of the gas at the point of use. A better
surface finish will make the pipe system easier
to clean and reduce the risk of particles being
released into the gas stream.
Central gas supply.
HiQ® Specialty gas program.Equipment & gas distribution systems.
CopperCopper has been used within gas supply tech-
nology for a long time and is still an option
when using industrial grade gas. Make sure
only to use cleaned copper tubing.
Stainless steelOver the past years, stainless steel has become
the number one choice of material for pure gas
applications. This is primarily because the mate-
rial is easy to clean and can be supplied with a
very good surface finish.
The increasing use of chemically reactive gases
and the great demands made on purity have
also contributed towards this trend. Welding
methods have been developed which provide
advantages with assembly in confined areas
and which make it possible to join stainless
steel systems while still maintaining a level of
cleanliness and finish. Stainless steel is also
chosen purely for aesthetic reasons or where
the environment is aggressive and can give rise
to corrosion. As a general guide the selection of
components for a gas supply system is always
based on the chosen gas quality.
Standard purity specialty gases(Equivalent to 2.5 [99.5%] to 6.0 [99.9999%])
Component: Stainless steel or brass depending
on the gas to be used. Threaded connectors,
type NPT or G.
Piping: Washed stainless steel.
Connection: Orbital welding compression cou-
plings, designed to clamp onto the pipe. The
coupling requires the pipe to have a good de-
gree of roundness (stainless steel) and gives a
seal equivalent to 10–6 bar cm3/s.
High purity specialty gases(Equivalent to 6.0 [99.9999] or higher)
Component: Stainless steel or brass depending
on the gas to be used. Threaded connectors,
type NPT or G.
Piping: Washed stainless steel.
Connection: VCR couplings, welded onto the
pipes and valves. Using a pointed profile that,
under a great pressure from two sides, is
pressed into metallic packing seals the cou-
plings. The coupling gives a seal equivalent to
10–8 – 10–10 bar cm3/s.
System design and start-upSystem design can be broken down intothree stages:• Determine the maximum contamination level
for the gas.
• Select the components to be used for the gas
supply system.
• Design, assemble and commission the system.
Linde has extensive know-how within the gas
industry and experience of gas media and appli-
cations – everything from component selection,
1
2
34
0.5 1.5 2.0 2.5 h1.0
50
40
30
20
10
2
ppm
O content in
the purging gas2
The figure illustrates the relation between purge time,
purging method and the purity realized with regard to
the oxygen content in a gas system.
1 = Constant flow 10 l/h
2 = 5 x pressurized/decompression ∅P 3 bar
3 = 7 x pressurized/decompression ∅P 3 bar
4 = 10 x pressurized/decompression ∅P 3 bar
HiQ® Specialty gas program.Equipment & gas distribution systems.
via system design to installation and start-up –
as well as all technical documentation.
Linde acts as advisor and consultant together
with the user in order to assess the require-
ments and conditions of the project in question.
It is extremely important to look at the system
in its entirety, both from an economic and
safety point of view.
Highlighted below are some of the areas that
greatly affect the whole system.
Distribution and storage• Arrange if possible a storage area for the gas
cylinders in a separate building.
• Connected gas cylinders are placed in a sepa-
rate area, preferably in adjacent to the access
area. Avoid transporting gas cylinders indoors.
• The gases are stored (separately) according to
fixed directives depending on their physical
characteristics.
• Ventilation is provided based on safety re-
quirements regarding the amount and type of
gas used.
Gas cabinets and pipe systems• Separate gas cabinets should be considered
for corrosive gases and toxic gases.
• When using extremely dangerous gases there
is a possibility of flow control and emergency
stop functions.
• Gas pipes should be run in such a manner that
the risk of mechanical damage is eliminated
and that, as far as possible, through areas
where any leaking gas causes as little dam-
age as possible.
Detection and alarms• The need of detection is assessed. Regard
should be taken to future requirements con-
cerning types of gas and suitable flexibility to
avoid unnecessary costs at a later stage.
• The possibility of an auto-stop if a leak is indi-
cated. This can be achieved using detection
equipment.
• The need of an alarm to an operating centre
and/or an evacuation alarm within a certain
area is defined.
Linde has well-trained assembly teams with
vast experience of specialty gas installations.
Central gas supply.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Each team has a supervisor who is responsible
for the completion of the project and at the
same time functions as an on-site contact per-
son.
Pipe and components are delivered sealed and
well packed to the assembly area.
To maintain the purity requirements and to pro-
duce a tight gas system, automatic computer
controlled pipe welding equipment is used. All
welding is carried out using internal and exter-
nal shield-gas purging, which results in clean
and bright joints.
Pressure testing according to applicable stan-
dards is carried out and a protocol is estab-
lished.
A complete system is purged clean and ana-
lyzed to determine the humidity and oxygen
content.
To guarantee that a system is tight, we carry
out a helium leak detection test. A certificate of
tightness is drawn up. Before a gas supply sys-
tem can be regarded as completed and is
handed over for start-up it is documented.
A complete set of documentation comprises:• Layout documents (show the entire supply
systems design and positions in respective
buildings).
• System specifications including equipment
lists.
• Technical information covering all compo-
nents.
• Spare part lists.
• Pressure testing protocols.
• Analysis certificates where applicable.
• Tightness certificates where applicable.
• Operating and servicing instructions.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Group green equipment for inert and non-
reactive gases used as carrier gas or likewise,
where gas integrity is non-crucial at cylinder
change.
S 200
Group blue equipment, with own gas purge,
for inert and non-reactive gases and gas mix-
tures where gas integrity is important at cylin-
der change.
S 201
S 202
D 204
A 208
Group orange equipment, with purge gas
(nitrogen or likewise) purging, for toxic and re-
active gases and gas mixtures, where gas in-
tegrity and safety is important at cylinder
change.
S 203
A 209
Gas panels are used in central gas supplysystems for reducing the high primarypressure in the cylinders to more manage-able secondary pressures and is the placewhere the cylinders are changed, etc. It canbe considered the heart of the central gassystem.
Linde has three types of gas panels: Single,
double and semi-automatic. Single panels han-
dle one cylinder or bundle at a time. When the
cylinder/bundle is empty it has to be changed.
Double panels handle two cylinders or bundles
(or a combination) at a time. When the cylinder
or bundle is empty, switchover has to be done
manually. Semi-automatic panels handle two
cylinders/bundles at a time. When the pres-
sure at one side (the primary side) reaches a
pre-set value the manifold “switches” to the
other side. This means that it is possible to
change the gas cylinders without interrupting
the gas flow. After the cylinders at the primary
side are changed the handle is turned, thus
changing the secondary side (delivering the
gas) to the new primary side.
It is possible to create a fully automatic mani-
fold, with either electric or pneumatic valves,
but since the cylinders have to be changed any-
way the cost is rarely justified.
Note: Gas panels are not supplied with cylinder
connections. For information on avail-
able cylinder connections, please contact
your local Linde representative.
HiQ® REDLINE Gas panels.The starting point.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Gas panels S 200. Single gas panel.Single stage gas supply panel designed for pure gases and mixtures.
Technical data
Inlet primary pressure 230 bar 3,300 psi
Outlet pressure 0.5–6 bar 8–85 psi
2.5–14 bar 35–200 psi
2.5–50 bar 35–725 psi
10–200 bar 145–3,000 psi
Outlet gauge range –1–10 bar –14.5–145 psi
0–25 bar 0–360 psi
0–80 bar 0–1,400 psi
0–315 bar 0–4,500 psi
Operating temperature –20 – +70°C –4 – +158°F
Connection 1, 2 or 4 cylinders
Process gas in NPT 1/4” female
Process gas out NPT 1/4” female
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
DescriptionGas panel S 200 is designed for single cylinders or bundles. It is mounted
on a stainless steel console and consists of a pressure regulator, inlet and
outlet pressure gauges, a relief valve and a shut-off valve for the process
gas.
All measurements in millimeters.
Drawings of other types available on request.
~ 160 245
100
30
155
60
To process
Processgas inlet
3
0
6
0
9
3 6 9 12 15 18 21 23 27
Flow, Nm3/h N2
Downstream pressure, bar
* Set pressure
10 bar*
Max flow
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 200
B 6 85 3409
B 14 200 3144
B 50 725 3410
B 200 3,000 3411
SS 6 85 3412
SS 14 200 3145
SS 50 725 3413
SS 200 3,000 3414
S 200 coil and 1 cylinder
B C1 6 85 3497
B C1 14 200 3498
B C1 50 725 3499
B C1 200 3,000 3500
SS C1 6 85 4450
SS C1 14 200 3533
SS C1 50 725 3534
SS C1 200 3,000 3535
S 200 coil and 2 cylinders
B C2 6 85 3501
B C2 14 200 3502
B C2 50 725 3503
B C2 200 3,000 3504
SS C2 6 85 3536
SS C2 14 200 3537
SS C2 50 725 3538
SS C2 200 3,000 3539
S 200 coil and 4 cylinders
B C4 6 85 3505
B C4 14 200 3506
B C4 50 725 3507
B C4 200 3,000 3508
SS C4 6 85 3540
SS C4 14 200 3541
SS C4 50 725 3542
SS C4 200 3,000 3543
Specifications bar psi HiQ® code
S200 short flexihose and 1 cylinder
B SH1 6 85 3509
B SH1 14 200 3510
B SH1 50 725 3511
B SH1 200 3,000 3512
SS SH1 6 85 3544
SS SH1 14 200 3545
SS SH1 50 725 3546
SS SH1 200 3,000 3547
S 200 short flexihose and 2 cylinders
B SH2 6 85 3513
B SH2 14 200 3514
B SH2 50 725 3515
B SH2 200 3,000 3516
SS SH2 6 85 3548
SS SH2 14 200 3549
SS SH2 50 725 3550
SS SH2 200 3,000 3551
S 200 short flexihose and 4 cylinders
B SH4 6 85 3517
B SH4 14 200 3518
B SH4 50 725 3519
B SH4 200 3,300 3520
SS SH4 6 85 3552
SS SH4 14 200 3553
SS SH4 50 725 3554
SS SH4 200 3,000 3555
S 200 long flexihose and 1 cylinder
B LH1 6 85 3521
B LH1 14 200 3522
B LH1 50 725 3523
B LH1 200 3,000 3524
SS LH1 6 85 3556
SS LH1 14 200 3557
SS LH1 50 725 3558
SS LH1 200 3,000 3559
Specifications bar psi HiQ® code
S 200 long flexihose and 2 cylinders
B LH2 6 85 3525
B LH2 14 200 3526
B LH2 50 725 3527
B LH2 200 3,000 3528
SS LH2 6 85 3560
SS LH2 14 200 3561
SS LH2 50 725 3562
SS LH2 200 3,000 3563
S 200 long flexihose and 4 cylinders
B LH4 6 85 3529
B LH4 14 200 3530
B LH4 50 725 3531
B LH4 200 3,000 3532
SS LH4 6 85 3564
SS LH4 14 200 3565
SS LH4 50 725 3566
SS LH4 200 3,000 3567
S 200C contact gauge
B C 6 85 4465
B C 14 200 4466
B C 50 725 4467
B C 200 3,000 4468
SS C 6 85 4505
SS C 14 200 4506
SS C 50 725 4507
SS C 200 3,000 4508
Gas panels S 200. Product names and codes.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 200C contact gauge, coil and 1cylinder
B C C1 6 85 4469
B C C1 14 200 4470
B C C1 50 725 4471
B C C1 200 3,000 4472
SS C C1 6 85 4509
SS C C1 14 200 4510
SS C C1 50 725 4511
SS C C1 200 3,000 4512
S 200C contact gauge, coil and 2cylinders
B C C2 6 85 4473
B C C2 14 200 4474
B C C2 50 725 4475
B C C2 200 3,000 4476
SS C C2 6 85 4513
SS C C2 14 200 4514
SS C C2 50 725 4515
SS C C2 200 3,000 4516
S 200C contact gauge, coil and 4cylinders
B C C4 6 85 4477
B C C4 14 200 4478
B C C4 50 725 4479
B C C4 200 3,000 4480
SS C C4 6 85 4517
SS C C4 14 200 4518
SS C C4 50 725 4519
SS C C4 200 3,000 4520
Specifications bar psi HiQ® code
S 200C contact gauge, short flexihoseand 1 cylinder
B C SH1 6 85 4481
B C SH1 14 200 4482
B C SH1 50 725 4483
B C SH1 200 3,000 4484
SS C SH1 6 85 4521
SS C SH1 14 200 4522
SS C SH1 50 725 4523
SS C SH1 200 3,000 4524
S 200C contact gauge, short flexihoseand 2 cylinders
B C SH2 6 85 4485
B C SH2 14 200 4486
B C SH2 50 725 4487
B C SH2 200 3,000 4488
SS C SH2 6 85 4525
SS C SH2 14 200 4526
SS C SH2 50 725 4527
SS C SH2 200 3,000 4528
S 200C contact gauge, short flexihoseand 4 cylinders
B C SH4 6 85 4489
B C SH4 14 200 4490
B C SH4 50 725 4491
B C SH4 200 3,000 4492
SS C SH4 6 85 4529
SS C SH4 14 200 4530
SS C SH4 50 725 4531
SS C SH4 200 3,000 4532
Specifications bar psi HiQ® code
S 200C contact gauge,long flexihoseand 1 cylinder
B C LH1 6 85 4493
B C LH1 14 200 4494
B C LH1 50 725 4495
B C LH1 200 3,000 4496
SS C LH1 6 85 4533
SS C LH1 14 200 4534
SS C LH1 50 725 4535
SS C LH1 200 3,000 4536
S 200C contact gauge, long flexihoseand 2 cylinders
B C LH2 6 85 4497
B C LH2 14 200 4498
B C LH2 50 725 4499
B C LH2 200 3,000 4500
SS C LH2 6 85 4537
SS C LH2 14 200 4538
SS C LH2 50 725 4539
SS C LH2 200 3,000 4540
S 200C contact gauge, long flexihoseand 4 cylinders
B C LH4 6 85 4501
B C LH4 14 200 4502
B C LH4 50 725 4503
B C LH4 200 3,000 4504
SS C LH4 6 85 4541
SS C LH4 14 200 4542
SS C LH4 50 725 4543
SS C LH4 200 3,000 4544
B = Brass
SS = Stainless steel
Cx = Coil and number of cylinders
SHx = Short flexihose and number of cylinders
LHx = Long flexihose and number of cylinders
C = Contact gauge
R = Residual gas outlet
RC = Residual gas outlet and contact gauge
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Gas panels S 201. Single gas panel.Single stage gas supply panel with internal gas purging, designed for high purity gases and mixtures (including flammable).
Technical data
Inlet primary pressure 230 bar 3,300 psi
Outlet pressure 0.5–6 bar 8–85 psi
2.5–14 bar 35–200 psi
2.5–50 bar 35–725 psi
10–200 bar 145–3,000 psi
Outlet gauge range –1–10 bar –14.5–145 psi
0–25 bar 0–360 psi
0–80 bar 0–1,400 psi
0–315 bar 0–4,500 psi
Operating temperature –20 – +70°C –4 – +158°F
Connection 1, 2 or 4 cylinders
Process gas in NPT 1/4” female
Process gas out NPT 1/4” female
Purge gas outlet NPT 1/4” female
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
DescriptionGas panel S 201 is designed for single cylinders or bundles. It is equipped
with internal gas purging to avoid contaminants entering the process line
after changing the cylinders. It is mounted on a stainless steel console
and consists of a pressure regulator, inlet and outlet pressure gauges, a
relief valve and shut-off valves for the process gas and for the purge gas.
The panel can also be equipped with contact gauge (/C models) for auto-
matic surveillance. When applicable the panel can be ordered with
residual gas line (/R models) connecting the relief valve with the purge
outlet.
All measurements in millimeters.
Model R. Drawings of other types available on request.
~ 160 245
100
15
5
60
∅ 6
To process To ventilation
Processgas inlet
3
0
6
0
9
3 6 9 12 15 18 21 23 27
Flow, Nm3/h N2
Downstream pressure, bar
* Set pressure
10 bar*
Max flow
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 201
B 6 85 3415
B 14 200 3146
B 50 725 3416
B 200 3,000 3417
SS 6 85 3418
SS 14 200 3147
SS 50 725 3419
SS 200 3,000 3420
S 201 coil and 1 cylinder
B C1 6 85 3568
B C1 14 200 3569
B C1 50 725 3570
B C1 200 3,000 3571
SS C1 6 85 3640
SS C1 14 200 3641
SS C1 50 725 3642
SS C1 200 3,000 3643
S 201 coil and 2 cylinders
B C2 6 85 3572
B C2 14 200 3573
B C2 50 725 3574
B C2 200 3,000 3575
SS C2 6 85 3644
SS C2 14 200 3645
SS C2 50 725 3646
SS C2 200 3,000 3647
S 201 coil and 4 cylinders
B C4 6 85 3576
B C4 14 200 3577
B C4 50 725 3578
B C4 200 3,000 3579
SS C4 6 85 3648
SS C4 14 200 3649
SS C4 50 725 3650
SS C4 200 3,000 3651
Specifications bar psi HiQ® code
S 201 short flexihose and 1 cylinder
B SH1 6 85 3580
B SH1 14 200 3581
B SH1 50 725 3582
B SH1 200 3,000 3583
SS SH1 6 85 3652
SS SH1 14 200 3653
SS SH1 50 725 3654
SS SH1 200 3,000 3655
S 201 short flexihose and 2 cylinders
B SH2 6 85 3584
B SH2 14 200 3585
B SH2 50 725 3586
B SH2 200 3,000 3587
SS SH2 6 85 3656
SS SH2 14 200 3657
SS SH2 50 725 3658
SS SH2 200 3,000 3659
S 201 short flexihose and 4 cylinders
B SH4 6 85 3588
B SH4 14 200 3589
B SH4 50 725 3590
B SH4 200 3,000 3591
SS SH4 6 85 3660
SS SH4 14 200 3661
SS SH4 50 725 3662
SS SH4 200 3,000 3663
S 201 long flexihose and 1 cylinder
B LH1 6 85 3592
B LH1 14 200 3593
B LH1 50 725 3594
B LH1 200 3,000 3595
SS LH1 6 85 3664
SS LH1 14 200 3665
SS LH1 50 725 3666
SS LH1 200 3,000 3667
Specifications bar psi HiQ® code
S 201 long flexihose and 2 cylinder
B LH2 6 85 3596
B LH2 14 200 3597
B LH2 50 725 3598
B LH2 200 3,000 3599
SS LH2 6 85 3668
SS LH2 14 200 3669
SS LH2 50 725 3670
SS LH2 200 3,000 3671
S 201 long flexihose and 4 cylinders
B LH4 6 85 3600
B LH4 14 200 3601
B LH4 50 725 3602
B LH4 200 3,000 3603
SS LH4 6 85 3672
SS LH4 14 200 3673
SS LH4 50 725 3674
SS LH4 200 3,000 3675
S 201/R residual gas outlet
B R 6 85 3471
B R 14 200 3472
B R 50 725 3473
B R 200 3,000 3474
SS R 6 85 3475
SS R 14 200 3476
SS R 50 725 3477
SS R 200 3,000 3478
SS R C1 200 3,000 3679
Gas panels S 201. Product names and codes.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 201/R residual gas outlet, coil and1 cylinder
B R C1 6 85 3604
B R C1 14 200 3605
B R C1 50 725 3606
B R C1 200 3,000 3607
SS R C1 6 85 3676
SS R C1 14 200 3677
SS R C1 50 725 3678
S 201/R residual gas outlet, coil and2 cylinders
B R C2 6 85 3608
B R C2 14 200 3609
B R C2 50 725 3610
B R C2 200 3,000 3611
SS R C2 6 85 3680
SS R C2 14 200 3681
SS R C2 50 725 3682
SS R C2 200 3,000 3683
S 201/R residual gas outlet, coil and4 cylinders
B R C4 6 85 3612
B R C4 14 200 3613
B R C4 50 725 3614
B R C4 200 3,000 3615
SS R C4 6 85 3684
SS R C4 14 200 3685
SS R C4 50 725 3686
SS R C4 200 3,000 3687
Specifications bar psi HiQ® code
S 201/R residual gas outlet, shortflexihose and 1 cylinder
B R SH1 6 85 3616
B R SH1 14 200 3617
B R SH1 50 725 3618
B R SH1 200 3,000 3619
SS R SH1 6 85 3688
SS R SH1 14 200 3689
SS R SH1 50 725 3690
SS R SH1 200 3,000 3691
S 201/R residual gas outlet, shortflexihose and 2 cylinders
B R SH2 6 85 3620
B R SH2 14 200 3621
B R SH2 50 725 3622
B R SH2 200 3,000 3623
SS R SH2 6 85 3692
SS R SH2 14 200 3693
SS R SH2 50 725 3694
SS R SH2 200 3,000 3695
S 201/R residual gas outlet, shortflexihose and 4 cylinders
B R SH4 6 85 3624
B R SH4 14 200 3625
B R SH4 50 725 3626
B R SH4 200 3,000 3627
SS R SH4 6 85 3696
SS R SH4 14 200 3697
SS R SH4 50 725 3698
SS R SH4 200 3,000 3699
Specifications bar psi HiQ® code
S 201/R residual gas outlet, longflexihose and 1 cylinder
B R LH1 6 85 3628
B R LH1 14 200 3629
B R LH1 50 725 3630
B R LH1 200 3,000 3631
SS R LH1 6 85 3700
SS R LH1 14 200 3701
SS R LH1 50 725 3702
SS R LH1 200 3,000 3703
S 201/R residual gas outlet, longflexihose and 2 cylinders
B R LH2 6 85 3632
B R LH2 14 200 3633
B R LH2 50 725 3634
B R LH2 200 3,000 3635
SS R LH2 6 85 3704
SS R LH2 14 200 3705
SS R LH2 50 725 3706
SS R LH2 200 3,000 3707
S 201/R residual gas outlet, longflexihose and 4 cylinders
B R LH4 6 85 3636
B R LH4 14 200 3637
B R LH4 50 725 3638
B R LH4 200 3,000 3639
SS R LH4 6 85 3708
SS R LH4 14 200 3709
SS R LH4 50 725 3710
SS R LH4 200 3,000 3711
B = Brass
SS = Stainless steel
Cx = Coil and number of cylinders
SHx = Short flexihose and number of cylinders
LHx = Long flexihose and number of cylinders
C = Contact gauge
R = Residual gas outlet
RC = Residual gas outlet and contact gauge
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 201/C contact gauge
B C 6 85 4545
B C 14 200 4546
B C 50 725 4547
B C 200 3,000 4548
SS C 6 85 4625
SS C 14 200 4626
SS C 50 725 4627
SS C 200 3,000 4628
S 201/C contact gauge, coil and 1cylinder
B C C1 6 85 4549
B C C1 14 200 4550
B C C1 50 725 4551
B C C1 200 3,000 4552
SS C C1 6 85 4629
SS C C1 14 200 4630
SS C C1 50 725 4631
SS C C1 200 3,000 4632
S 201/C contact gauge, coil and 2cylinders
B C C2 6 85 4553
B C C2 14 200 4554
B C C2 50 725 4555
B C C2 200 3,000 4556
SS C C2 6 85 4633
SS C C2 14 200 4634
SS C C2 50 725 4635
SS C C2 200 3,000 4636
S 201/C contact gauge, coil and 4cylinders
B C C4 6 85 4557
B C C4 14 200 4558
B C C4 50 725 4559
B C C4 200 3,000 4560
SS C C4 6 85 4637
Specifications bar psi HiQ® code
SS C C4 14 200 4638
SS C C4 50 725 4639
SS C C4 200 3,000 4640
S 201/C contact gauge, shortflexihose and 1 cylinder
B C SH1 6 85 4561
B C SH1 14 200 4562
B C SH1 50 725 4563
B C SH1 200 3,000 4564
SS C SH1 6 85 4641
SS C SH1 14 200 4642
SS C SH1 50 725 4643
SS C SH1 200 3,000 4644
S 201/C contact gauge, shortflexihose and 2 cylinders
B C SH2 6 85 4565
B C SH2 14 200 4566
B C SH2 50 725 4567
B C SH2 200 3,000 4568
SS C SH2 6 85 4645
SS C SH2 14 200 4646
SS C SH2 50 725 4647
SS C SH2 200 3,000 4648
S 201/C contact gauge, shortflexihose and 4 cylinders
B C SH4 6 85 4569
B C SH4 14 200 4570
B C SH4 50 725 4571
B C SH4 200 3,000 4572
SS C SH4 6 85 4649
SS C SH4 14 200 4650
SS C SH4 50 725 4651
SS C SH4 200 3,000 4652
Specifications bar psi HiQ® code
S 201/C contact gauge, longflexihose and 1 cylinderB C LH1 6 85 4573
B C LH1 14 200 4574
B C LH1 50 725 4575
B C LH1 200 3,000 4576
SS C LH1 6 85 4653
SS C LH1 14 200 4654
SS C LH1 50 725 4655
SS C LH1 200 3,000 4656
S 201/C contact gauge, longflexihose and 2 cylinders
B C LH2 6 85 4577
B C LH2 14 200 4578
B C LH2 50 725 4579
B C LH2 200 3,000 4580
SS C LH2 6 85 4657
SS C LH2 14 200 4658
SS C LH2 50 725 4659
SS C LH2 200 3,000 4660
S 201/C contact gauge, longflexihose and 4 cylinders
B C LH4 6 85 4581
B C LH4 14 200 4582
B C LH4 50 725 4583
B C LH4 200 3,000 4584
SS C LH4 6 85 4661
SS C LH4 14 200 4662
SS C LH4 50 725 4663
SS C LH4 200 3,000 4664
Gas panels S 201. Product names and codes.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 201/RC residual gas outlet, contactgauge
B RC 6 85 4585
B RC 14 200 4586
B RC 50 725 4587
B RC 200 3,000 4588
SS RC 6 85 4665
SS RC 14 200 4666
SS RC 50 725 4667
SS RC 200 3,000 4668
S 201/RC residual gas outlet, contactgauge, coil and 1 cylinder
B RC C1 6 85 4589
B RC C1 14 200 4590
B RC C1 50 725 4591
B RC C1 200 3,000 4592
SS RC C1 6 85 4669
SS RC C1 14 200 4670
SS RC C1 50 725 4671
SS RC C1 200 3,000 4672
S 201/RC residual gas outlet, contactgauge, coil and 2 cylinders
B RC C2 6 85 4593
B RC C2 14 200 4594
B RC C2 50 725 4595
B RC C2 200 3,000 4596
SS RC C2 6 85 4673
SS RC C2 14 200 4674
SS RC C2 50 725 4675
SS RC C2 200 3,000 4676
S 201/RC residual gas outlet, contactgauge, coil and 4 cylinders
B RC C4 6 85 4597
B RC C4 14 200 4598
B RC C4 50 725 4599
Specifications bar psi HiQ® code
B RC C4 200 3,000 4600
SS RC C4 6 85 4677
SS RC C4 14 200 4678
SS RC C4 50 725 4679
SS RC C4 200 3,000 4680
S 201/RC residual gas outlet, contactgauge, short flexihose and 1 cylinderB RC SH1 6 85 4601
B RC SH1 14 200 4602
B RC SH1 50 725 4603
B RC SH1 200 3,000 4604
SS RC SH1 6 85 4681
SS RC SH1 14 200 4682
SS RC SH1 50 725 4683
SS RC SH1 200 3,000 4684
S 201/RC residual gas outlet, contactgauge, short flexihose and 2cylinders
B RC SH2 6 85 4605
B RC SH2 14 200 4606
B RC SH2 50 725 4607
B RC SH2 200 3,000 4608
SS RC SH2 6 85 4685
SS RC SH2 14 200 4686
SS RC SH2 50 725 4687
SS RC SH2 200 3,000 4688
S 201/RC residual gas outlet, contactgauge, short flexihose and 4 cylinders
B RC SH4 6 85 4609
B RC SH4 14 200 4610
B RC SH4 50 725 4611
B RC SH4 200 3,000 4612
SS RC SH4 6 85 4689
SS RC SH4 14 200 4690
SS RC SH4 50 725 4691
SS RC SH4 200 3,000 4692
Specifications bar psi HiQ® code
S 201/RC residual gas outlet, contactgauge, long flexihose and 1 cylinder
B RC LH1 6 85 4613
B RC LH1 14 200 4614
B RC LH1 50 725 4615
B RC LH1 200 3,000 4616
SS RC LH1 6 85 4693
SS RC LH1 14 200 4694
SS RC LH1 50 725 4695
SS RC LH1 200 3,000 4696
S 201/RC residual gas outlet, contactgauge, long flexihose and 2 cylinders
B RC LH2 6 85 4617
B RC LH2 14 200 4618
B RC LH2 50 725 4619
B RC LH2 200 3,000 4620
SS RC LH2 6 85 4697
SS RC LH2 14 200 4698
SS RC LH2 50 725 4699
SS RC LH2 200 3,000 4700
S 201/RC residual gas outlet, contactgauge, long flexihose and 4 cylinders
B RC LH4 6 85 4621
B RC LH4 14 200 4622
B RC LH4 50 725 4623
B RC LH4 200 3,000 4624
SS RC LH4 6 85 4701
SS RC LH4 14 200 4702
SS RC LH4 50 725 4703
SS RC LH4 200 3,000 4704
B = Brass
SS = Stainless steel
Cx = Coil and number of cylinders
SHx = Short flexihose and number of cylinders
LHx = Long flexihose and number of cylinders
C = Contact gauge
R = Residual gas outlet
RC = Residual gas outlet and contact gauge
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Gas panels S 202. Single gas panel.Single stage gas supply panel with internal gas purging, designed for pure gases and mixtures.
Technical data
Inlet primary pressure 230 bar 3,300 psi
Outlet pressure 0.5–6 bar 8–85 psi
2.5–14 bar 35–200 psi
2.5–50 bar 35–725 psi
10–200 bar 145–3,000 psi
Outlet gauge range –1–10 bar –14.5–145 psi
0–25 bar 0–360 psi
0–80 bar 0–1,400 psi
0–315 bar 0–4,500 psi
Operating temperature –20 – +70°C –4 – +158°F
Connection 1, 2 or 4 cylinders
Process gas in NPT 1/4” female
Process gas out NPT 1/4” female
Purge gas outlet NPT 1/4” female
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
DescriptionGas panel S 202 is designed for single cylinders or bundles. It is equipped
with internal gas purging to avoid contaminants entering the process line
after changing the cylinders. It is is mounted on a stainless steel console
and consists of a pressure regulator, inlet and outlet pressure gauges, a
relief valve and shut-off valves for the process gas at high and low pres-
sure ends and for the purging gas.
The panel can also be equipped with contact gauge (/C models) for auto-
matic surveillance. When applicable the panel can be ordered with resid-
ual gas line (/R models) connecting the relief valve with the purge
outlet.
All measurements in millimeters.
Model R. Drawings of other types available on request.
~ 160
30
245
100
155
60
To process To ventilation
Processgas inlet
3
0
6
0
9
3 6 9 12 15 18 21 23 27
Flow, Nm3/h N2
Downstream pressure, bar
* Set pressure
10 bar*
Max flow
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 202
B 6 85 3421
B 14 200 3148
B 50 725 3422
B 200 3,000 3423
SS 6 85 3424
SS 14 200 3149
SS 50 725 3425
SS 200 3,000 3426
S 202 coil and 1 cylinder
B C1 6 85 3712
B C1 14 200 3713
B C1 50 725 3714
B C1 200 3,000 3715
SS C1 6 85 3784
SS C1 14 200 3785
SS C1 50 725 3786
SS C1 200 3,000 3787
S 202 coil and 2 cylinders
B C2 6 85 3716
B C2 14 200 3717
B C2 50 725 3718
B C2 200 3,000 3719
SS C2 6 85 3788
SS C2 14 200 3789
SS C2 50 725 3790
SS C2 200 3,000 3791
S 202 coil and 4 cylinders
B C4 6 85 3720
B C4 14 200 3721
B C4 50 725 3722
B C4 200 3,000 3723
SS C4 6 85 3792
SS C4 14 200 3793
SS C4 50 725 3794
SS C4 200 3,000 3795
Specifications bar psi HiQ® code
S 202 short flexihose and 1 cylinder
B SH1 6 85 3724
B SH1 14 200 3725
B SH1 50 725 3726
B SH1 200 3,000 3727
SS SH1 6 85 3796
SS SH1 14 200 3797
SS SH1 50 725 3798
SS SH1 200 3,000 3799
S 202 short flexihose and 2 cylinders
B SH2 6 85 3728
B SH2 14 200 3729
B SH2 50 725 3730
B SH2 200 3,000 3731
SS SH2 6 85 3800
SS SH2 14 200 3801
SS SH2 50 725 3802
SS SH2 200 3,000 3803
S 202 short flexihose and 4 cylinders
B SH4 6 85 3732
B SH4 14 200 3733
B SH4 50 725 3734
B SH4 200 3,000 3735
SS SH4 6 85 3804
SS SH4 14 200 3805
SS SH4 50 725 3806
SS SH4 200 3,000 3807
S 202 long flexihose and 1 cylinder
B LH1 6 85 3736
B LH1 14 200 3737
B LH1 50 725 3738
B LH1 200 3,000 3739
SS LH1 6 85 3808
SS LH1 14 200 3809
SS LH1 50 725 3810
SS LH1 200 3,000 3811
Specifications bar psi HiQ® code
S 202 long flexihose and 2 cylinders
B LH2 6 85 3740
B LH2 14 200 3741
B LH2 50 725 3742
B LH2 200 3,000 3743
SS LH2 6 85 3812
SS LH2 14 200 3813
SS LH2 50 725 3814
SS LH1 200 3,000 3815
S 202 long flexihose and 4 cylinders
B LH4 6 85 3744
B LH4 14 200 3745
B LH4 50 725 3746
B LH4 200 3,000 3747
SS LH4 6 85 3816
SS LH4 14 200 3817
SS LH4 50 725 3818
SS LH4 200 3,000 3819
S 202/R residual gas outlet
B R 6 85 3479
B R 14 200 3480
B R 50 725 3481
B R 200 3,000 3482
SS R 6 85 3483
SS R 14 200 3484
SS R 50 725 3485
SS R 200 3,000 3486
Gas panels S 202. Product names and codes.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 202/R residual gas outlet, coil and1 cylinder
B R C1 6 85 3748
B R C1 14 200 3749
B R C1 50 725 3750
B R C1 200 3,000 3751
SS R C1 6 85 3820
SS R C1 14 200 3821
SS R C1 50 725 3822
SS R C1 200 3,000 3823
S 202/R residual gas outlet, coil and2 cylinders
B R C2 6 85 3752
B R C2 14 200 3753
B R C2 50 725 3754
B R C2 200 3,000 3755
SS R C2 6 85 3824
SS R C2 14 200 3825
SS R C2 50 725 3826
SS R C2 200 3,000 3827
S 202/R residual gas outlet, coil and4 cylinders
B R C4 6 85 3756
B R C4 14 200 3757
B R C4 50 725 3758
B R C4 200 3,000 3759
SS R C4 6 85 3828
SS R C4 14 200 3829
SS R C4 50 725 3830
SS R C4 200 3,000 3831
S 202/R residual gas outlet, shortflexihose and 1 cylinder
B R SH1 6 85 3760
B R SH1 14 200 3761
B R SH1 50 725 3762
B R SH1 200 3,000 3763
Specifications bar psi HiQ® code
SS R SH1 6 85 3832
SS R SH1 14 200 3833
SS R SH1 50 725 3834
SS R SH1 200 3,000 3835
S 202/R residual gas outlet, shortflexihose and 2 cylinders
B R SH2 6 85 3764
B R SH2 14 200 3765
B R SH2 50 725 3766
B R SH2 200 3,000 3767
SS R SH2 6 85 3836
SS R SH2 14 200 3837
SS R SH2 50 725 3838
SS R SH2 200 3,000 3839
S 202/R residual gas outlet, shortflexihose and 4 cylinders
B R SH4 6 85 3768
B R SH4 14 200 3769
B R SH4 50 725 3770
B R SH4 200 3,000 3771
SS R SH4 6 85 3840
SS R SH4 14 200 3841
SS R SH4 50 725 3842
SS R SH4 200 3,000 3843
S 202/R residual gas outlet, longflexihose and 1 cylinder
B R LH1 6 85 3772
B R LH1 14 200 3773
B R LH1 50 725 3774
B R LH1 200 3,000 3775
SS R LH1 6 85 3844
SS R LH1 14 200 3845
SS R LH1 50 725 3846
SS R LH1 200 3,000 3847
Specifications bar psi HiQ® code
S 202/R residual gas outlet, longflexihose and 2 cylinders
B R LH2 6 85 3776
B R LH2 14 200 3777
B R LH2 50 725 3778
B R LH2 200 3,000 3779
SS R LH2 6 85 3848
SS R LH2 14 200 3849
SS R LH2 50 725 3850
SS R LH2 200 3,000 3851
S 202/R residual gas outlet, longflexihose and 4 cylinders
B R LH4 6 85 3780
B R LH4 14 200 3781
B R LH4 50 725 3782
B R LH4 200 3,000 3783
SS R LH4 6 85 3852
SS R LH4 14 200 3853
SS R LH4 50 725 3854
SS R LH4 200 3,000 3855
S 202/C contact gauge
B C 6 85 4705
B C 14 200 4706
B C 50 725 4707
B C 200 3,000 4708
SS C 6 85 4785
SS C 14 200 4786
SS C 50 725 4787
SS C 200 3,000 4788
B = Brass
SS = Stainless steel
Cx = Coil and number of cylinders
SHx = Short flexihose and number of cylinders
LHx = Long flexihose and number of cylinders
C = Contact gauge
R = Residual gas outlet
RC = Residual gas outlet and contact gauge
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 202/C contact gauge, coil and 1cylinder
B C C1 6 85 4709
B C C1 14 200 4710
B C C1 50 725 4711
B C C1 200 3,000 4712
SS C C1 6 85 4789
SS C C1 14 200 4790
SS C C1 50 725 4791
SS C C1 200 3,000 4792
S 202/C contact gauge, coil and 2cylinders
B C C2 6 85 4713
B C C2 14 200 4714
B C C2 50 725 4715
B C C2 200 3,000 4716
SS C C2 6 85 4793
SS C C2 14 200 4794
SS C C2 50 725 4795
SS C C2 200 3,000 4796
S 202/C contact gauge, coil and 4cylinders
B C C4 6 85 4717
B C C4 14 200 4718
B C C4 50 725 4719
B C C4 200 3,000 4720
SS C C4 6 85 4797
SS C C4 14 200 4798
SS C C4 50 725 4799
SS C C4 200 3,000 4800
S 202/C contact gauge, shortflexihose and 1 cylinder
B C SH1 6 85 4721
B C SH1 14 200 4722
B C SH1 50 725 4723
B C SH1 200 3,000 4724
Specifications bar psi HiQ® code
SS C SH1 6 85 4801
SS C SH1 14 200 4802
SS C SH1 50 725 4803
SS C SH1 200 3,000 4804
S 202/C contact gauge, shortflexihose and 2 cylinders
B C SH2 6 85 4725
B C SH2 14 200 4726
B C SH2 50 725 4727
B C SH2 200 3,000 4728
SS C SH2 6 85 4805
SS C SH2 14 200 4806
SS C SH2 50 725 4807
SS C SH2 200 3,000 4808
S 202/C contact gauge, shortflexihose and 4 cylinders
B C SH4 6 85 4729
B C SH4 14 200 4730
B C SH4 50 725 4731
B C SH4 200 3,000 4732
SS C SH4 6 85 4809
SS C SH4 14 200 4810
SS C SH4 50 725 4811
SS C SH4 200 3,000 4812
S 202/C contact gauge, longflexihose and 1 cylinder
B C LH1 6 85 4733
B C LH1 14 200 4734
B C LH1 50 725 4735
B C LH1 200 3,000 4736
SS C LH1 6 85 4813
SS C LH1 14 200 4814
SS C LH1 50 725 4815
SS C LH1 200 3,000 4816
Specifications bar psi HiQ® code
S 202/C contact gauge, longflexihose and 2 cylinders
B C LH2 6 85 4737
B C LH2 14 200 4738
B C LH2 50 725 4739
B C LH2 200 3,000 4740
SS C LH2 6 85 4817
SS C LH2 14 200 4818
SS C LH2 50 725 4819
SS C LH2 200 3,000 4820
S 202/C contact gauge, longflexihose and 4 cylinders
B C LH4 6 85 4741
B C LH4 14 200 4742
B C LH4 50 725 4743
B C LH4 200 3,000 4744
SS C LH4 6 85 4821
SS C LH4 14 200 4822
SS C LH4 50 725 4823
SS C LH4 200 3,000 4824
S 202/RC residual gas outlet,contactgauge
B RC 6 85 4745
B RC 14 200 4746
B RC 50 725 4747
B RC 200 3,000 4748
SS RC 6 85 4825
SS RC 14 200 4826
SS RC 50 725 4827
SS RC 200 3,000 4828
Gas panels S 202. Product names and codes.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 202/RC residual gas outlet, contactgauge, coil and 1 cylinder
B RC C1 6 85 4749
B RC C1 14 200 4750
B RC C1 50 725 4751
B RC C1 200 3,000 4752
SS RC C1 6 85 4829
SS RC C1 14 200 4830
SS RC C1 50 725 4831
SS RC C1 200 3,000 4832
S 202/RC residual gas outlet, contactgauge, coil and 2 cylinders
B RC C2 6 85 4753
B RC C2 14 200 4754
B RC C2 50 725 4755
B RC C2 200 3,000 4756
SS RC C2 6 85 4833
SS RC C2 14 200 4834
SS RC C2 50 725 4835
SS RC C2 200 3,000 4836
S 202/RC residual gas outlet, contactgauge, coil and 4 cylinders
B RC C4 6 85 4757
B RC C4 14 200 4758
B RC C4 50 725 4759
B RC C4 200 3,000 4760
SS RC C4 6 85 4837
SS RC C4 14 200 4838
SS RC C4 50 725 4839
SS RC C4 200 3,000 4840
Specifications bar psi HiQ® code
S 202/RC residual gas outlet, contactgauge, short flexihose and 1 cylinder
B RC SH1 6 85 4761
B RC SH1 14 200 4762
B RC SH1 50 725 4763
B RC SH1 200 3,000 4764
SS RC SH1 6 85 4841
SS RC SH1 14 200 4842
SS RC SH1 50 725 4843
SS RC SH1 200 3,000 4844
S 202/RC residual gas outlet, contactgauge, short flexihose and 2 cylinders
B RC SH2 6 85 4765
B RC SH2 14 200 4766
B RC SH2 50 725 4767
B RC SH2 200 3,000 4768
SS RC SH2 6 85 4845
SS RC SH2 14 200 4846
SS RC SH2 50 725 4847
SS RC SH2 200 3,000 4848
S 202/RC residual gas outlet, contactgauge, short flexihose and 4 cylinders
B RC SH4 6 85 4769
B RC SH4 14 200 4770
B RC SH4 50 725 4771
B RC SH4 200 3,000 4772
SS RC SH4 6 85 4849
SS RC SH4 14 200 4850
SS RC SH4 50 725 4851
SS RC SH4 200 3,000 4852
Specifications bar psi HiQ® code
S 202/RC residual gas outlet, contactgauge, long flexihose and 1 cylinder
B RC LH1 6 85 4773
B RC LH1 14 200 4774
B RC LH1 50 725 4775
B RC LH1 200 3,000 4776
SS RC LH1 6 85 4853
SS RC LH1 14 200 4854
SS RC LH1 50 725 4855
SS RC LH1 200 3,000 4856
S 202/RC residual gas outlet, contactgauge, long flexihose and 2 cylinders
B RC LH2 6 85 4777
B RC LH2 14 200 4778
B RC LH2 50 725 4779
B RC LH2 200 3,000 4780
SS RC LH2 6 85 4857
SS RC LH2 14 200 4858
SS RC LH2 50 725 4859
SS RC LH2 200 3,000 4860
S 202/RC residual gas outlet, contactgauge, long flexihose and 4 cylinder
B RC LH4 6 85 4781
B RC LH4 14 200 4782
B RC LH4 50 725 4783
B RC LH4 200 3,000 4784
SS RC LH4 6 85 4861
SS RC LH4 14 200 4862
SS RC LH4 50 725 4863
SS RC LH4 200 3,000 4864
B = Brass
SS = Stainless steel
Cx = Coil and number of cylinders
SHx = Short flexihose and number of cylinders
LHx = Long flexihose and number of cylinders
C = Contact gauge
R = Residual gas outlet
RC = Residual gas outlet and contact gauge
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Gas panels S 203. Single gas panel.Single stage gas supply panel with external gas purging, designed for reactive, toxic and corrosive gases.
Technical data
Inlet primary pressure 230 bar 3,300 psi
Outlet pressure 0.5–6 bar 8–85 psi
2.5–14 bar 35–200 psi
2.5–50 bar 35–725 psi
10–200 bar 145–3,000 psi
Outlet gauge range –1–10 bar –14.5–145 psi
0–25 bar 0–360 psi
0–80 bar 0–1,400 psi
0–315 bar 0–4,500 psi
Operating temperature –20 – +70°C –4 – +158°F
Connection 1, 2 or 4 cylinders
Process gas in NPT 1/4” female
Process gas out NPT 1/4” female
Purge gas inlet Tube fitting 6 mm
Purge gas outlet Tube fitting 6 mm
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
DescriptionGas panel S 203 is designed for single cylinders or bundles. It is equipped
with external gas purging to allow purging of the high pressure side be-
fore disconnecting cylinders. It is is mounted on a stainless steel console
and consists of a pressure regulator, inlet and outlet pressure gauges, a
relief valve and shut-off valves for the process gas at high and low pres-
sure ends and for the purging gas.
The panel can also be equipped with contact gauge (/C models) for auto-
matic surveillance. When applicable the panel can be ordered with resid-
ual gas line (/R models) connecting the relief valve with the purge outlet.
155
60
~ 160
30
100
245
23
∅ 6
∅ 6
To process To ventilation
Processgas inlet
Purgegas inlet
3
0
6
0
9
3 6 9 12 15 18 21 23 27
Flow, Nm3/h N2
Downstream pressure, bar
* Set pressure
10 bar*
Max flow
All measurements in millimeters.
Model R. Drawings of other types available on request.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 203
B 6 85 3427
B 14 200 3150
B 50 725 3428
B 200 3,000 3429
SS 6 85 3430
SS 14 200 3151
SS 50 725 3431
SS 200 3,000 3432
S 203 coil and 1 cylinder
B C1 6 85 3856
B C1 14 200 3857
B C1 50 725 3858
B C1 200 3,000 3859
SS C1 6 85 3892
SS C1 14 200 3893
SS C1 50 725 3894
SS C1 200 3,000 3895
S 203 coil and 2 cylinders
B C2 6 85 3860
B C2 14 200 3861
B C2 50 725 3862
B C2 200 3,000 3863
SS C2 6 85 3896
SS C2 14 200 3897
SS C2 50 725 3898
SS C2 200 3,000 3899
S 203 coil and 4 cylinders
B C4 6 85 3864
B C4 14 200 3865
B C4 50 725 3866
B C4 200 3,000 3867
SS C4 6 85 3900
SS C4 14 200 3901
SS C4 50 725 3902
SS C4 200 3,000 3903
Specifications bar psi HiQ® code
S 203 short flexihose and 1 cylinder
B SH1 6 85 3868
B SH1 14 200 3869
B SH1 50 725 3870
B SH1 200 3,000 3871
SS SH1 6 85 3904
SS SH1 14 200 3905
SS SH1 50 725 3906
SS SH1 200 3,000 3907
S 203 short flexihose and 2 cylinders
B SH2 6 85 3872
B SH2 14 200 3873
B SH2 50 725 3874
B SH2 200 3,000 3875
SS SH2 6 85 3908
SS SH2 14 200 3909
SS SH2 50 725 3910
SS SH2 200 3,000 3911
S 203 short flexihose and 4 cylinders
B SH4 6 85 3876
B SH4 14 200 3877
B SH4 50 725 3878
B SH4 200 3,000 3879
SS SH4 6 85 3912
SS SH4 14 200 3913
SS SH4 50 725 3914
SS SH4 200 3,000 3915
S 203 long flexihose and 1 cylinder
B LH1 6 85 3880
B LH1 14 200 3881
B LH1 50 725 3882
B LH1 200 3,000 3883
SS LH1 6 85 3916
SS LH1 14 200 3917
SS LH1 50 725 3918
SS LH1 200 3,000 3919
Specifications bar psi HiQ® code
S 203 long flexihose and 2 cylinders
B LH2 6 85 3884
B LH2 14 200 3885
B LH2 50 725 3886
B LH2 200 3,000 3887
SS LH2 6 85 3920
SS LH2 14 200 3921
SS LH2 50 725 3922
SS LH2 200 3,000 3923
S 203 long flexihose and 4 cylinders
B LH4 6 85 3888
B LH4 14 200 3889
B LH4 50 725 3890
B LH4 200 3,000 3891
SS LH4 6 85 3924
SS LH4 14 200 3925
SS LH4 50 725 3926
SS LH4 200 3,000 3927
S 203/R residual gas outlet
B R 6 85 4865
B R 14 200 4866
B R 50 725 4867
B R 200 3,000 4868
SS R 6 85 4985
SS R 14 200 4986
SS R 50 725 4987
SS R 200 3,000 4988
Gas panels S 203. Product names and codes.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 203/R residual gas outlet, coil and1 cylinder
B R C1 6 85 4869
B R C1 14 200 4870
B R C1 50 725 4871
B R C1 200 3,000 4872
SS R C1 6 85 4989
SS R C1 14 200 4990
SS R C1 50 725 4991
SS R C1 200 3,000 4992
S 203/R residual gas outlet, coil and2 cylinders
B R C2 6 85 4873
B R C2 14 200 4874
B R C2 50 725 4875
B R C2 200 3,000 4876
SS R C2 6 85 4993
SS R C2 14 200 4994
SS R C2 50 725 4995
SS R C2 200 3,000 4996
S 203/R residual gas outlet, coil and4 cylinders
B R C4 6 85 4877
B R C4 14 200 4878
B R C4 50 725 4879
B R C4 200 3,000 4880
SS R C4 6 85 4997
SS R C4 14 200 4998
SS R C4 50 725 4999
SS R C4 200 3,000 5000
S 203/R residual gas outlet, shortflexihose and 1 cylinder
B R SH1 6 85 4881
B R SH1 14 200 4882
B R SH1 50 725 4883
B R SH1 200 3,000 4884
Specifications bar psi HiQ® code
SS R SH1 6 85 5001
SS R SH1 14 200 5002
SS R SH1 50 725 5003
SS R SH1 200 3,000 5004
S 203/R residual gas outlet, shortflexihose and 2 cylinders
B R SH2 6 85 4885
B R SH2 14 200 4886
B R SH2 50 725 4887
B R SH2 200 3,000 4888
SS R SH2 6 85 5005
SS R SH2 14 200 5006
SS R SH2 50 725 5007
SS R SH2 200 3,000 5008
S 203/R residual gas outlet, shortflexihose and 4 cylinders
B R SH4 6 85 4889
B R SH4 14 200 4890
B R SH4 50 725 4891
B R SH4 200 3,000 4892
SS R SH4 6 85 5009
SS R SH4 14 200 5010
SS R SH4 50 725 5011
SS R SH4 200 3,000 5012
S 203/R residual gas outlet, longflexihose and 1 cylinder
B R LH1 6 85 4893
B R LH1 14 200 4894
B R LH1 50 725 4895
B R LH1 200 3,000 4896
SS R LH1 6 85 5013
SS R LH1 14 200 5014
SS R LH1 50 725 5015
SS R LH1 200 3,000 5016
Specifications bar psi HiQ® code
S 203/R residual gas outlet, longflexihose and 2 cylinders
B R LH2 6 85 4897
B R LH2 14 200 4898
B R LH2 50 725 4899
B R LH2 200 3,000 4900
SS R LH2 6 85 5017
SS R LH2 14 200 5018
SS R LH2 50 725 5019
SS R LH2 200 3,000 5020
S 203/R residual gas outlet, longflexihose and 4 cylinders
B R LH4 6 85 4901
B R LH4 14 200 4902
B R LH4 50 725 4903
B R LH4 200 3,000 4904
SS R LH4 6 85 5021
SS R LH4 14 200 5022
SS R LH4 50 725 5023
SS R LH4 200 3,000 5024
S 203/C contact gauge
B C 6 85 4905
B C 14 200 4906
B C 50 725 4907
B C 200 3,000 4908
SS C 6 85 5025
SS C 14 200 5026
SS C 50 725 5027
SS C 200 3,000 5028
B = Brass
SS = Stainless steel
Cx = Coil and number of cylinders
SHx = Short flexihose and number of cylinders
LHx = Long flexihose and number of cylinders
C = Contact gauge
R = Residual gas outlet
RC = Residual gas outlet and contact gauge
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 203/C contact gauge, coil and 1cylinder
B C C1 6 85 4909
B C C1 14 200 4910
B C C1 50 725 4911
B C C1 200 3,000 4912
SS C C1 6 85 5029
SS C C1 14 200 5030
SS C C1 50 725 5031
SS C C1 200 3,000 5032
S 203/C contact gauge, coil and 2cylinders
B C C2 6 85 4913
B C C2 14 200 4914
B C C2 50 725 4915
B C C2 200 3,000 4916
SS C C2 6 85 5033
SS C C2 14 200 5034
SS C C2 50 725 5035
SS C C2 200 3,000 5036
S 203/C contact gauge, coil and 4cylinders
B C C4 6 85 4917
B C C4 14 200 4918
B C C4 50 725 4919
B C C4 200 3,000 4920
SS C C4 6 85 5037
SS C C4 14 200 5038
SS C C4 50 725 5039
SS C C4 200 3,000 5040
S 203/C contact gauge, shortflexihose and 1 cylinder
B C SH1 6 85 4921
B C SH1 14 200 4922
B C SH1 50 725 4923
B C SH1 200 3,000 4924
Specifications bar psi HiQ® code
SS C SH1 6 85 5041
SS C SH1 14 200 5042
SS C SH1 50 725 5043
SS C SH1 200 3,000 5044
S 203/C contact gauge, shortflexihose and 2 cylinders
B C SH2 6 85 4925
B C SH2 14 200 4926
B C SH2 50 725 4927
B C SH2 200 3,000 4928
SS C SH2 6 85 5045
SS C SH2 14 200 5046
SS C SH2 50 725 5047
SS C SH2 200 3,000 5048
S 203/C contact gauge, shortflexihose and 4 cylinders
B C SH4 6 85 4929
B C SH4 14 200 4930
B C SH4 50 725 4931
B C SH4 200 3,000 4932
SS C SH4 6 85 5049
SS C SH4 14 200 5050
SS C SH4 50 725 5051
SS C SH4 200 3,000 5052
S 203/C contact gauge, longflexihose and 1 cylinder
B C LH1 6 85 4933
B C LH1 14 200 4934
B C LH1 50 725 4935
B C LH1 200 3,000 4936
SS C LH1 6 85 5053
SS C LH1 14 200 5054
SS C LH1 50 725 5055
SS C LH1 200 3,000 5056
Specifications bar psi HiQ® code
S 203/C contact gauge, longflexihose and 2 cylinders
B C LH2 6 85 4937
B C LH2 14 200 4938
B C LH2 50 725 4939
B C LH2 200 3,000 4940
SS C LH2 6 85 5057
SS C LH2 14 200 5058
SS C LH2 50 725 5059
SS C LH2 200 3,000 5060
S 203/C contact gauge, longflexihose and 4 cylinders
B C LH4 6 85 4941
B C LH4 14 200 4942
B C LH4 50 725 4943
B C LH4 200 3,000 4944
SS C LH4 6 85 5061
SS C LH4 14 200 5062
SS C LH4 50 725 5063
SS C LH4 200 3,000 5064
S 203/RC residual gas outlet, contactgauge
B RC 6 85 4945
B RC 14 200 4946
B RC 50 725 4947
B RC 200 3,000 4948
SS RC 6 85 5065
SS RC 14 200 5066
SS RC 50 725 5067
SS RC 200 3,000 5068
Gas panels S 203. Product names and codes.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
S 203/RC residual gas outlet, contactgauge, coil and 1 cylinder
B RC C1 6 85 4949
B RC C1 14 200 4950
B RC C1 50 725 4951
B RC C1 200 3,000 4952
SS RC C1 6 85 5069
SS RC C1 14 200 5070
SS RC C1 50 725 5071
SS RC C1 200 3,000 5072
S 203/RC residual gas outlet, contactgauge, coil and 2 cylinders
B RC C2 6 85 4953
B RC C2 14 200 4954
B RC C2 50 725 4955
B RC C2 200 3,000 4956
SS RC C2 6 85 5073
SS RC C2 14 200 5074
SS RC C2 50 725 5075
SS RC C2 200 3,000 5076
S 203/RC residual gas outlet, contactgauge, coil and 4 cylinders
B RC C4 6 85 4957
B RC C4 14 200 4958
B RC C4 50 725 4959
B RC C4 200 3,000 4960
SS RC C4 6 85 5077
SS RC C4 14 200 5078
SS RC C4 50 725 5079
SS RC C4 200 3,000 5080
Specifications bar psi HiQ® code
S 203/RC residual gas outlet, contactgauge, short flexihose and 1 cylinder
B RC SH1 6 85 4961
B RC SH1 14 200 4962
B RC SH1 50 725 4963
B RC SH1 200 3,000 4964
SS RC SH1 6 85 5081
SS RC SH1 14 200 5082
SS RC SH1 50 725 5083
SS RC SH1 200 3,000 5084
S 203/RC residual gas outlet, contactgauge, short flexihose and 2 cylinders
B RC SH2 6 85 4965
B RC SH2 14 200 4966
B RC SH2 50 725 4967
B RC SH2 200 3,000 4968
SS RC SH2 6 85 5085
SS RC SH2 14 200 5086
SS RC SH2 50 725 5087
SS RC SH2 200 3,000 5088
S 203/RC residual gas outlet, contactgauge, short flexihose and 4 cylinders
B RC SH4 6 85 4969
B RC SH4 14 200 4970
B RC SH4 50 725 4971
B RC SH4 200 3,000 4972
SS RC SH4 6 85 5089
SS RC SH4 14 200 5090
SS RC SH4 50 725 5091
SS RC SH4 200 3,000 5092
Specifications bar psi HiQ® code
S 203/RC residual gas outlet, contactgauge, long flexihose and 1 cylinder
B RC LH1 6 85 4973
B RC LH1 14 200 4974
B RC LH1 50 725 4975
B RC LH1 200 3,000 4976
SS RC LH1 6 85 5093
SS RC LH1 14 200 5094
SS RC LH1 50 725 5095
SS RC LH1 200 3,000 5096
S 203/RC residual gas outlet, contactgauge, long flexihose and 2 cylinders
B RC LH2 6 85 4977
B RC LH2 14 200 4978
B RC LH2 50 725 4979
B RC LH2 200 3,000 4980
SS RC LH2 6 85 5097
SS RC LH2 14 200 5098
SS RC LH2 50 725 5099
SS RC LH2 200 3,000 5100
S 203/RC residual gas outlet, contactgauge, long flexihose and 4 cylinders
B RC LH4 6 85 4981
B RC LH4 14 200 4982
B RC LH4 50 725 4983
B RC LH4 200 3,000 4984
SS RC LH4 6 85 5101
SS RC LH4 14 200 5102
SS RC LH4 50 725 5103
SS RC LH4 200 3,000 5104
B = Brass
SS = Stainless steel
Cx = Coil and number of cylinders
SHx = Short flexihose and number of cylinders
LHx = Long flexihose and number of cylinders
C = Contact gauge
R = Residual gas outlet
RC = Residual gas outlet and contact gauge
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Gas panels D 204. Double gas panel.Single stage gas supply panel with internal gas purging, designed for high purity gases and mixtures (including flammable), with connectionfor 2x1 cylinder.
Technical data
Inlet primary pressure 230 bar 3,300 psi
Outlet pressure 0.5–6 bar 8–85 psi
2.5–14 bar 35–200 psi
2.5–50 bar 35–725 psi
10–200 bar 145–3,000 psi
Outlet gauge range –1–10 bar –14.5–145 psi
0–25 bar 0–360 psi
0–80 bar 0–1,400 psi
0–315 bar 0–4,500 psi
Operating temperature –20 – +70°C –4 – +158°F
Connection 2x1, 2x2 or 2x4 cylinders
Process gas in NPT 1/4” female
Process gas out NPT 1/4” female
Purge gas outlet Tube fitting 6 mm
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
DescriptionGas panel D 204 is designed for double cylinders or bundles. It is
equipped with internal gas purging to avoid contaminants entering the
process line after changing the cylinders. It is is mounted on a stainless
steel console and consists of a pressure regulator, inlet and outlet pres-
sure gauges, a relief valve and shut-off valves for the process gas at the
high pressure end and for the purging gas. The gas supply is uninterrupt-
ed during cylinder change. Switch-over is done manually.
The panel can also be equipped with a contact gauge (/C models) for au-
tomatic surveillance. When applicable the panel can be ordered with
residual gas line (/R models) connecting the relief valve with the purge
outlet.
~18
0 155
60
245158
To process To ventilation
Processgas inlet
3
0
6
0
9
3 6 9 12 15 18 21 23 27
Flow, Nm3/h N2
Downstream pressure, bar
* Set pressure
10 bar*
Max flow
All measurements in millimeters.
Model R. Drawings of other types available on request.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
D 204
B 6 85 3433
B 14 200 3152
B 50 725 3434
B 200 3,000 3435
SS 6 85 3436
SS 14 200 3153
SS 50 725 3437
SS 200 3,000 3438
D 204 coil and 2 cylinders
B C2 6 85 3928
B C2 14 200 3929
B C2 50 725 3930
B C2 200 3,000 3931
SS C2 6 85 3964
SS C2 14 200 3965
SS C2 50 725 3966
SS C2 200 3,000 3967
D 204 coil and 4 cylinders
B C4 6 85 3932
B C4 14 200 3933
B C4 50 725 3934
B C4 200 3,000 3935
SS C4 6 85 3968
SS C4 14 200 3969
SS C4 50 725 3970
SS C4 200 3,000 3971
D 204 coil and 8 cylinders
B C8 6 85 3936
B C8 14 200 3937
B C8 50 725 3938
B C8 200 3,000 3939
SS C8 6 85 3972
SS C8 14 200 3973
SS C8 50 725 3974
SS C8 200 3,000 3975
Specifications bar psi HiQ® code
D 204 short flexihose and 2 cylinders
B SH2 6 85 3940
B SH2 14 200 3941
B SH2 50 725 3942
B SH2 200 3,000 3943
SS SH2 6 85 3976
SS SH2 14 200 3977
SS SH2 50 725 3978
SS SH2 200 3,000 3979
D 204 short flexihose and 4 cylinders
B SH4 6 85 3944
B SH4 14 200 3945
B SH4 50 725 3946
B SH4 200 3,000 3947
SS SH4 6 85 3980
SS SH4 14 200 3981
SS SH4 50 725 3982
SS SH4 200 3,000 3983
D 204 short flexihose and 8 cylinders
B SH8 6 85 3948
B SH8 14 200 3949
B SH8 50 725 3950
B SH8 200 3,000 3951
SS SH8 6 85 3984
SS SH8 14 200 3985
SS SH8 50 725 3986
SS SH8 200 3,000 3987
D 204 long flexihose and 2 cylinders
B LH2 6 85 3952
B LH2 14 200 3953
B LH2 50 725 3954
B LH2 200 3,000 3955
SS LH2 6 85 3988
SS LH2 14 200 3989
SS LH2 50 725 3990
SS LH2 200 3,000 3991
Specifications bar psi HiQ® code
D 204 long flexihose and 4 cylinders
B LH4 6 85 3956
B LH4 14 200 3957
B LH4 50 725 3958
B LH4 200 3,000 3959
SS LH4 6 85 3992
SS LH4 14 200 3993
SS LH4 50 725 3994
SS LH4 200 3,000 3995
D 204 long flexihose and 8 cylinders
B LH8 6 85 3960
B LH8 14 200 3961
B LH8 50 725 3962
B LH8 200 3,000 3963
SS LH8 6 85 3996
SS LH8 14 200 3997
SS LH8 50 725 3998
SS LH8 200 3,000 3999
D 204/R residual gas outlet
B R 6 85 5105
B R 14 200 5106
B R 50 725 5107
B R 200 3,000 5108
SS R 6 85 5145
SS R 14 200 5146
SS R 50 725 5147
SS R 200 3,000 5148
D 204/R residual gas outlet, coil and2 cylinders
B R C2 6 85 5109
B R C2 14 200 5110
B R C2 50 725 5111
B R C2 200 3,000 5112
Gas panels D 204. Product names and codes.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
SS R C2 6 85 5149
SS R C2 14 200 5150
SS R C2 50 725 5151
SS R C2 200 3,000 5152
D 204/R residual gas outlet, coil and4 cylinders
B R C4 6 85 5113
B R C4 14 200 5114
B R C4 50 725 5115
B R C4 200 3,000 5116
SS R C4 6 85 5153
SS R C4 14 200 5154
SS R C4 50 725 5155
SS R C4 200 3,000 5156
D 204/R residual gas outlet, coil and8 cylinders
B R C8 6 85 5117
B R C8 14 200 5118
B R C8 50 725 5119
B R C8 200 3,000 5120
SS R C8 6 85 5157
SS R C8 14 200 5158
SS R C8 50 725 5159
SS R C8 200 3,000 5160
D 204/R residual gas outlet, shortflexihose and 2 cylinders
B R SH2 6 85 5121
B R SH2 14 200 5122
B R SH2 50 725 5123
B R SH2 200 3,000 5124
SS R SH2 6 85 5161
SS R SH2 14 200 5162
SS R SH2 50 725 5163
SS R SH2 200 3,000 5164
Specifications bar psi HiQ® code
D 204/R residual gas outlet, shortflexihose and 4 cylinders
B R SH4 6 85 5125
B R SH4 14 200 5126
B R SH4 50 725 5127
B R SH4 200 3,000 5128
SS R SH4 6 85 5165
SS R SH4 14 200 5166
SS R SH4 50 725 5167
SS R SH4 200 3,000 5168
D 204/R residual gas outlet, shortflexihose and 8 cylinders
B R SH8 6 85 5129
B R SH8 14 200 5130
B R SH8 50 725 5131
B R SH8 200 3,000 5132
SS R SH8 6 85 5169
SS R SH8 14 200 5170
SS R SH8 50 725 5171
SS R SH8 200 3,000 5172
D 204/R residual gas outlet, longflexihose and 2 cylinders
B R LH2 6 85 5133
B R LH2 14 200 5134
B R LH2 50 725 5135
B R LH2 200 3,000 5136
SS R LH2 6 85 5173
SS R LH2 14 200 5174
SS R LH2 50 725 5175
SS R LH2 200 3,000 5176
D 204/R residual gas outlet, longflexihose and 4 cylinders
B R LH4 6 85 5137
B R LH4 14 200 5138
B R LH4 50 725 5139
B R LH4 200 3,000 5140
Specifications bar psi HiQ® code
SS R LH4 6 85 5177
SS R LH4 14 200 5178
SS R LH4 50 725 5179
SS R LH4 200 3,000 5180
D 204/R residual gas outlet, longflexihose and 8 cylinders
B R LH8 6 85 5141
B R LH8 14 200 5142
B R LH8 50 725 5143
B R LH8 200 3,000 5144
SS R LH8 6 85 5181
SS R LH8 14 200 5182
SS R LH8 50 725 5183
SS R LH8 200 3,000 5184
D 204/C contact gauge
B C 6 85 3439
B C 14 200 3154
B C 50 725 3440
B C 200 3,000 3441
SS C 6 85 3442
SS C 14 200 3155
SS C 50 725 3443
SS C 200 3,000 3444
D 204/C contact gauge, coil and 2cylinders
B C C2 6 85 4000
B C C2 14 200 4001
B C C2 50 725 4002
B C C2 200 3,000 4003
SS C C2 6 85 4036
SS C C2 14 200 4037
SS C C2 50 725 4038
SS C C2 200 3,000 4039
B = Brass
SS = Stainless steel
Cx = Coil and number of cylinders
SHx = Short flexihose and number of cylinders
LHx = Long flexihose and number of cylinders
C = Contact gauge
R = Residual gas outlet
RC = Residual gas outlet and contact gauge
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
D 204/C contact gauge, coil and 4cylinders
B C C4 6 85 4004
B C C4 14 200 4005
B C C4 50 725 4006
B C C4 200 3,000 4007
SS C C4 6 85 4040
SS C C4 14 200 4041
SS C C4 50 725 4042
SS C C4 200 3,000 4043
D 204/C contact gauge, coil and 8cylinders
B C C8 6 85 4008
B C C8 14 200 4009
B C C8 50 725 4010
B C C8 200 3,000 4011
SS C C8 6 85 4044
SS C C8 14 200 4045
SS C C8 50 725 4046
SS C C8 200 3,000 4047
D 204/C contact gauge, shortflexihose and 2 cylinders
B C SH2 6 85 4012
B C SH2 14 200 4013
B C SH2 50 725 4014
B C SH2 200 3,000 4015
SS C SH2 6 85 4048
SS C SH2 14 200 4049
SS C SH2 50 725 4050
SS C SH2 200 3,000 4051
Specifications bar psi HiQ® code
D 204/C contact gauge, shortflexihose and 4 cylinders
B C SH4 6 85 4016
B C SH4 14 200 4017
B C SH4 50 725 4018
B C SH4 200 3,000 4019
SS C SH4 6 85 4052
SS C SH4 14 200 4053
SS C SH4 50 725 4054
SS C SH4 200 3,000 4055
D 204/C contact gauge, shortflexihose and 8 cylinders
B C SH8 6 85 4020
B C SH8 14 200 4021
B C SH8 50 725 4022
B C SH8 200 3,000 4023
SS C SH8 6 85 4056
SS C SH8 14 200 4057
SS C SH8 50 725 4058
SS C SH8 200 3,000 4059
D 204/C contact gauge, longflexihose and 2 cylinders
B C LH2 6 85 4024
B C LH2 14 200 4025
B C LH2 50 725 4026
B C LH2 200 3,000 4027
SS C LH2 6 85 4060
SS C LH2 14 200 4061
SS C LH2 50 725 4062
SS C LH2 200 3,000 4063
Specifications bar psi HiQ® code
D 204/C contact gauge, longflexihose and 4 cylinders
B C LH4 6 85 4028
B C LH4 14 200 4029
B C LH4 50 725 4030
B C LH4 200 3,000 4031
SS C LH4 6 85 4064
SS C LH4 14 200 4065
SS C LH4 50 725 4066
SS C LH4 200 3,000 4067
D 204/C contact gauge, longflexihose and 8 cylinders
B C LH8 6 85 4032
B C LH8 14 200 4033
B C LH8 50 725 4034
B C LH8 200 3,000 4035
SS C LH8 6 85 4068
SS C LH8 14 200 4069
SS C LH8 50 725 4070
SS C LH8 200 3,000 4071
D 204/RC residual gas outlet, contactgauge
B RC 6 85 5185
B RC 14 200 5186
B RC 50 725 5187
B RC 200 3,000 5188
SS RC 6 85 5225
SS RC 14 200 5226
SS RC 50 725 5227
SS RC 200 3,000 5228
Gas panels D 204. Product names and codes.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
D 204/RC residual gas outlet, contactgauge, coil and 2 cylinders
B RC C2 6 85 5189
B RC C2 14 200 5190
B RC C2 50 725 5191
B RC C2 200 3,000 5192
SS RC C2 6 85 5229
SS RC C2 14 200 5230
SS RC C2 50 725 5231
SS RC C2 200 3,000 5232
D 204/RC residual gas outlet, contactgauge, coil and 4 cylinders
B RC C4 6 85 5193
B RC C4 14 200 5194
B RC C4 50 725 5195
B RC C4 200 3,000 5196
SS RC C4 6 85 5233
SS RC C4 14 200 5234
SS RC C4 50 725 5235
SS RC C4 200 3,000 5236
D 204/RC residual gas outlet, contactgauge, coil and 8 cylinders
B RC C8 6 85 5197
B RC C8 14 200 5198
B RC C8 50 725 5199
B RC C8 200 3,000 5200
SS RC C8 6 85 5237
SS RC C8 14 200 5238
SS RC C8 50 725 5239
SS RC C8 200 3,000 5240
Specifications bar psi HiQ® code
D 204/RC residual gas outlet, contactgauge, short flexihose and 2 cylinders
B RC SH2 6 85 5201
B RC SH2 14 200 5202
B RC SH2 50 725 5203
B RC SH2 200 3,000 5204
SS RC SH2 6 85 5241
SS RC SH2 14 200 5242
SS RC SH2 50 725 5243
SS RC SH2 200 3,000 5244
D 204/RC residual gas outlet, contactgauge, short flexihose and 4 cylinders
B RC SH4 6 85 5205
B RC SH4 14 200 5206
B RC SH4 50 725 5207
B RC SH4 200 3,000 5208
SS RC SH4 6 85 5245
SS RC SH4 14 200 5246
SS RC SH4 50 725 5247
SS RC SH4 200 3,000 5248
D 204/RC residual gas outlet, contactgauge, short flexihose and 8 cylinders
B RC SH8 6 85 5209
B RC SH8 14 200 5210
B RC SH8 50 725 5211
B RC SH8 200 3,000 5212
SS RC SH8 6 85 5249
SS RC SH8 14 200 5250
SS RC SH8 50 725 5251
SS RC SH8 200 3,000 5252
Specifications bar psi HiQ® code
D 204/RC residual gas outlet, contactgauge, long flexihose and 2 cylinders
B RC LH2 6 85 5213
B RC LH2 14 200 5214
B RC LH2 50 725 5215
B RC LH2 200 3,000 5216
SS RC LH2 6 85 5253
SS RC LH2 14 200 5254
SS RC LH2 50 725 5255
SS RC LH2 200 3,000 5256
D 204/RC residual gas outlet, contactgauge, long flexihose and 4 cylinders
B RC LH4 6 85 5217
B RC LH4 14 200 5218
B RC LH4 50 725 5219
B RC LH4 200 3,000 5220
SS RC LH4 6 85 5257
SS RC LH4 14 200 5258
SS RC LH4 50 725 5259
SS RC LH4 200 3,000 5260
D 204/RC residual gas outlet, contactgauge, long flexihose and 4 cylinders
B RC LH8 6 85 5221
B RC LH8 14 200 5222
B RC LH8 50 725 5223
B RC LH8 200 3,000 5224
SS RC LH8 6 85 5261
SS RC LH8 14 200 5262
SS RC LH8 50 725 5263
SS RC LH8 200 3,000 5264
B = Brass
SS = Stainless steel
Cx = Coil and number of cylinders
SHx = Short flexihose and number of cylinders
LHx = Long flexihose and number of cylinders
C = Contact gauge
R = Residual gas outlet
RC = Residual gas outlet and contact gauge
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Gas panels A 208. Semi-automaticgas panel.Single stage, semi-automatic gas supply panel with internal gas purging, designed for high purity gases and mixtures.
Technical data
Inlet primary pressure 230 bar 3,300 psi
Outlet pressure 14 +3/–3 bar 200 +45/–45 psi
50 +8/–10 bar 725 +115/–145 psi
Operating temperature –20 – +70°C –4 – +158°F
Connection 2x1 to 2x4 cylinders
Process gas in NPT 1/4” female
Process gas out NPT 1/4” female
Purge gas outlet Tube fitting 6 mm
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
DescriptionGas panel A 208 is a semi-automatic gas panel designed for uninter-
rupted gas supply. Switch-over between the two connected cylinders or
bundles occurs when the pressure of one side (the primary side) falls
below a pre-set pressure level. This is achieved by two integrated regula-
tors (factory-set to slightly different delivery pressure levels) which are
connected at their outlet ports.
Semi-automatic supply panels should be connected to an alarm so that
the cylinders will be switched on time.
The panel can also be equipped with contact gauge (/C models) for auto-
matic surveillance. When applicable the panel can be ordered with resid-
ual gas line (/R models) connecting the relief valve with the purge
outlet.
Highlights• Continuous supply of pure gases
• Automatic switch over without auxiliary power
• Positive indication of active cylinder
• Process-gas purging system
• High flow capacity
• Compact design
~ 156
30
15
5
60
400
To processTo ventilation
Processgas inlet
Processgas inlet
4
0
8
0
12
16
5 1510 20 25 30 35
Flow, Nm3/h N2
Downstream pressure, bar
* Set pressure operating side ** Set pressure backup
12 bar**
16 bar*
Maxflo
w
All measurements in millimeters.
R model. Drawings of other types available on request.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
A 208
B 14 200 3164
B 50 725 3463
SS 14 200 3165
SS 50 725 3464
A 208 coil and 2 cylinders
B C2 14 200 4306
B C2 50 725 4307
SS C2 14 200 4324
SS C2 50 725 4325
A 208 coil and 4 cylinders
B C4 14 200 4308
B C4 50 725 4309
SS C4 14 200 4326
SS C4 50 725 4327
A 208 coil and 8 cylinders
B C8 14 200 4310
B C8 50 725 4311
SS C8 14 200 4328
SS C8 50 725 4329
A 208 short flexihose and 2 cylinders
B SH2 14 200 4312
B SH2 50 725 4313
SS SH2 14 200 4330
SS SH2 50 725 4331
A 208 short flexihose and 4 cylinders
B SH4 14 200 4314
B SH4 50 725 4315
SS SH4 14 200 4332
SS SH4 50 725 4333
A 208 short flexihose and 8 cylinders
B SH8 14 200 4316
B SH8 50 725 4317
SS SH8 14 200 4334
SS SH8 50 725 4335
A 208 long flexihose and 2 cylinders
B LH2 14 200 4318
B LH2 50 725 4319
Specifications bar psi HiQ® code
SS LH2 14 200 4336
SS LH2 50 725 4337
A 208 long flexihose and 4 cylinders
B LH4 14 200 4320
B LH4 50 725 4321
SS LH4 14 200 4338
SS LH4 50 725 4339
A 208 long flexihose and 8 cylinders
B LH8 14 200 4322
B LH8 50 725 4323
SS LH8 14 200 4340
SS LH8 50 725 4341
A 208/R residual gas outlet
B R 14 200 5265
B R 50 725 5266
SS R 14 200 5285
SS R 50 725 5286
A 208/R residual gas outlet, coil and2 cylinders
B R C2 14 200 5267
B R C2 50 725 5268
SS R C2 14 200 5287
SS R C2 50 725 5288
A 208/R residual gas outlet, coil and4 cylinders
B R C4 14 200 5269
B R C4 50 725 5270
SS R C4 14 200 5289
SS R C4 50 725 5290
A 208/R residual gas outlet, coil and8 cylinders
B R C8 14 200 5271
B R C8 50 725 5272
SS R C8 14 200 5291
SS R C8 50 725 5292
A 208/R residual gas outlet, shortflexihose and 2 cylinders
B R SH2 14 200 5273
B R SH2 50 725 5274
Specifications bar psi HiQ® code
SS R SH2 14 200 5293
SS R SH2 50 725 5294
A 208/R residual gas outlet, shortflexihose and 4 cylinders
B R SH4 14 200 5275
B R SH4 50 725 5276
SS R SH4 14 200 5295
SS R SH4 50 725 5296
A 208/R residual gas outlet, shortflexihose and 8 cylinders
B R SH8 14 200 5277
B R SH8 50 725 5278
SS R SH8 14 200 5297
SS R SH8 50 725 5298
A 208/R residual gas outlet, longflexihose and 2 cylinders
B R LH2 14 200 5279
B R LH2 50 725 5280
SS R LH2 14 200 5299
SS R LH2 50 725 5300
A 208/R residual gas outlet, longflexihose and 4 cylinders
B R LH4 14 200 5281
B R LH4 50 725 5282
SS R LH4 14 200 5301
SS R LH4 50 725 5302
A 208/R residual gas outlet, longflexihose and 8 cylinders
B R LH8 14 200 5283
B R LH8 50 725 5284
SS R LH8 14 200 5303
SS R LH8 50 725 5304
A 208/C contact gauge
B C 14 200 3166
B C 50 725 3465
SS C 14 200 3167
SS C 50 725 3466
Gas panels A 208. Product names and codes.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
A 208/C contact gauge, coil and 2cylinders
B C C2 14 200 4342
B C C2 50 725 4343
SS C C2 14 200 4360
SS C C2 50 725 4361
A 208/C contact gauge, coil and 4cylinders
B C C4 14 200 4344
B C C4 50 725 4345
SS C C4 14 200 4362
SS C C4 50 725 4363
A 208/C contact gauge, coil and 8cylinders
B C C8 14 200 4346
B C C8 50 725 4347
SS C C8 14 200 4364
SS C C8 50 725 4365
A 208/C contact gauge, shortflexihose and 2 cylinders
B C SH2 14 200 4348
B C SH2 50 725 4349
SS C SH2 14 200 4366
SS C SH2 50 725 4367
A 208/C contact gauge, shortflexihose and 4 cylinders
B C SH4 14 200 4350
B C SH4 50 725 4351
SS C SH4 14 200 4368
SS C SH4 50 725 4369
A 208/C contact gauge, shortflexihose and 8 cylinders
B C SH8 14 200 4352
B C SH8 50 725 4353
SS C SH8 14 200 4370
SS C SH8 50 725 4371
A 208/C contact gauge, longflexihose and 2 cylinders
B C LH2 14 200 4354
B C LH2 50 725 4355
Specifications bar psi HiQ® code
SS C LH2 14 200 4372
SS C LH2 50 725 4373
A 208/C contact gauge, longflexihose and 4 cylinders
B C LH4 14 200 4356
B C LH4 50 725 4357
SS C LH4 14 200 4374
SS C LH42 50 725 4375
A 208/C contact gauge, longflexihose and 8 cylinders
B C LH8 14 200 4358
B C LH8 50 725 4359
SS C LH8 14 200 4376
SS C LH8 50 725 4377
A 208/RC residual gas outlet, contactgauge
B RC 14 200 5305
B RC 50 725 5306
SS RC 14 200 5325
SS RC 50 725 5326
A 208/RC residual gas outlet, contactgauge, coil and 2 cylinders
B RC C2 14 200 5307
B RC C2 50 725 5308
SS RC C2 14 200 5327
SS RC C2 50 725 5328
A 208/RC residual gas outlet, contactgauge, coil and 4 cylinders
B RC C4 14 200 5309
B RC C4 50 725 5310
SS RC C4 14 200 5329
SS RC C4 50 725 5330
A 208/RC residual gas outlet, contactgauge, coil and 8 cylinders
B RC C8 14 200 5311
B RC C8 50 725 5312
SS RC C8 14 200 5331
SS RC C8 50 725 5332
Specifications bar psi HiQ® code
A 208/RC residual gas outlet, contactgauge, short flexihose and 2 cylinders
B RC SH2 14 200 5313
B RC SH2 50 725 5314
SS RC SH2 14 200 5333
SS RC SH2 50 725 5334
A 208/RC residual gas outlet, contactgauge, short flexihose and 4 cylinders
B RC SH4 14 200 5315
B RC SH4 50 725 5316
SS RC SH4 14 200 5335
SS RC SH4 50 725 5336
A 208/RC residual gas outlet, contactgauge, short flexihose and 8 cylinders
B RC SH8 14 200 5317
B RC SH8 50 725 5318
SS RC SH8 14 200 5337
SS RC SH8 50 725 5338
A 208/RC residual gas outlet, contactgauge, long flexihose and 2 cylinders
B RC LH2 14 200 5319
B RC LH2 50 725 5320
SS RC LH2 14 200 5339
SS RC LH2 50 725 5340
A 208/RC residual gas outlet, contactgauge, long flexihose and 4 cylinders
B RC LH4 14 200 5321
B RC LH4 50 725 5322
SS RC LH4 14 200 5341
SS RC LH4 50 725 5342
A 208/RC residual gas outlet, contactgauge,long flexihose and 8 cylinders
B RC LH8 14 200 5323
B RC LH8 50 725 5324
SS RC LH8 14 200 5343
SS RC LH8 50 725 5344
B = Brass
SS = Stainless steel
Cx = Coil and number of cylinders
SHx = Short flexihose and number of cylinders
LHx = Long flexihose and number of cylinders
C = Contact gauge
R = Residual gas outlet
RC = Residual gas outlet and contact gauge
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Gas panels A 209. Semi-automaticgas panel.Single stage, semi-automatic gas supply panel with external gas purging, designed for reactive, toxic and corrosive gases.
Technical data
Inlet primary pressure 230 bar 3,300 psi
Outlet pressure 14 +3/–3 bar 200 +45/–45 psi
50 +8/–10 bar 725 +115/–145 psi
Operating temperature –20 – +70°C –4 – +158°F
Connection 2x1 to 2x4 cylinders
Process gas in NPT 1/4” female
Process gas out NPT 1/4” female
Purge gas inlet NPT 1/4” female
Purge gas outlet Tube fitting 6 mm
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
DescriptionGas panel A 209 is a semi-automatic gas panel designed for uninter-
rupted gas supply. Switch-over between the two connected cylinders or
bundles occurs when the pressure of one side (the primary side) falls
below a pre-set pressure level. This is achieved by two integrated regula-
tors (factory-set to slightly different delivery pressure levels) which are
connected at their outlet ports.
Semi-automatic supply panels should be connected to an alarm so that
the cylinders will be switched on time.
The panel can also be equipped with contact gauge (/C models) for auto-
matic surveillance. When applicable the panel can be ordered with resid-
ual gas line (/R models) connecting the relief valve with the purge
outlet.
Highlights• Continuous supply of pure gases
• Automatic switch over without auxiliary power
• Positive indication of active cylinder
• Process-gas purging system
• High flow capacity
• Compact design
~ 218
550
15
56
0
∅ 6 ∅ 6
~ 156
30
To process
Purgegas inlet
To ventilation
Processgas inlet
Processgas inlet
Purgegas inlet
4
0
8
0
12
16
5 1510 20 25 30 35
Flow, Nm3/h N2
Downstream pressure, bar
* Set pressure operating side ** Set pressure backup
12 bar**
16 bar*
Maxflo
w
All measurements in millimeters.
R model. Drawings of other types available on request.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
A 209
B 14 200 3168
B 50 725 3467
SS 14 200 3169
SS 50 725 3468
A 209 coil and 2 cylinders
B C2 14 200 4378
B C2 50 725 4379
SS C2 14 200 4396
SS C2 50 725 4397
A 209 coil and 4 cylinders
B C4 14 200 4380
B C4 50 725 4381
SS C4 14 200 4398
SS C4 50 725 4399
A 209 coil and 8 cylinders
B C8 14 200 4382
B C8 50 725 4383
SS C8 14 200 4400
SS C8 50 725 4401
A 209 short flexihose and 2 cylinders
B SH2 14 200 4384
B SH2 50 725 4385
SS SH2 14 200 4402
SS SH2 50 725 4403
A 209 short flexihose and 4 cylinders
B SH4 14 200 4386
B SH4 50 725 4387
SS SH4 14 200 4404
SS SH4 50 725 4405
A 209 short flexihose and 8 cylinders
B SH8 14 200 4388
B SH8 50 725 4389
SS SH8 14 200 4406
SS SH8 50 725 4407
A 209 long flexihose and 2 cylinders
B LH2 14 200 4390
B LH2 50 725 4391
Specifications bar psi HiQ® code
SS LH2 14 200 4408
SS LH2 50 725 4409
A 209 long flexihose and 4 cylinders
B LH4 14 200 4392
B LH4 50 725 4393
SS LH4 14 200 4410
SS LH4 50 725 4411
A 209 long flexihose and 8 cylinders
B LH8 14 200 4394
B LH8 50 725 4395
SS LH8 14 200 4412
SS LH8 50 725 4413
A 209/R residual gas outlet
B R 14 200 5345
B R 50 725 5346
SS R 14 200 5365
SS R 50 725 5366
A 209/R residual gas outlet, coil and2 cylinders
B R C2 14 200 5347
B R C2 50 725 5348
SS R C2 14 200 5367
SS R C2 50 725 5368
A 209/R residual gas outlet, coil and4 cylinders
B R C4 14 200 5349
B R C4 50 725 5350
SS R C4 14 200 5369
SS R C4 50 725 5370
A 209/R residual gas outlet, coil and8 cylinders
B R C8 14 200 5351
B R C8 50 725 5352
SS R C8 14 200 5371
SS R C8 50 725 5372
A 209/R residual gas outlet, shortflexihose and 2 cylinders
B R SH2 14 200 5353
B R SH2 50 725 5354
Specifications bar psi HiQ® code
SS R SH2 14 200 5373
SS R SH2 50 725 5374
A 209/R residual gas outlet, shortflexihose and 4 cylinders
B R SH4 14 200 5355
B R SH4 50 725 5356
SS R SH4 14 200 5375
SS R SH4 50 725 5376
A 209/R residual gas outlet, shortflexihose and 8 cylinders
B R SH8 14 200 5357
B R SH8 50 725 5358
SS R SH8 14 200 5377
SS R SH8 50 725 5378
A 209/R residual gas outlet, longflexihose and 2 cylinders
B R LH2 14 200 5359
B R LH2 50 725 5360
SS R LH2 14 200 5379
SS R LH2 50 725 5380
A 209/R residual gas outlet, longflexihose and 4 cylinders
B R LH4 14 200 5361
B R LH4 50 725 5362
SS R LH4 14 200 5381
SS R LH4 50 725 5382
A 209/R residual gas outlet, longflexihose and 8 cylinders
B R LH8 14 200 5363
B R LH8 50 725 5364
SS R LH8 14 200 5383
SS R LH8 50 725 5384
A 209/C contact gauge
B C 14 200 3170
B C 50 725 3469
SS C 14 200 3171
SS C 50 725 3470
Gas panels A 209. Product names and codes.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Specifications bar psi HiQ® code
A 209/C contact gauge, coil and 2cylinders
B C C2 14 200 4414
B C C2 50 725 4415
SS C C2 14 200 4432
SS C C2 50 725 4433
A 209/C contact gauge, coil and 4cylinders
B C C4 14 200 4416
B C C44 50 725 4417
SS C C4 14 200 4434
SS C C4 50 725 4435
A 209/C contact gauge, coil and 8cylinders
B C C8 14 200 4418
B C C8 50 725 4419
SS C C8 14 200 4436
SS C C8 50 725 4437
A 209/C contact gauge, shortflexihose and 2 cylinders
B C SH2 14 200 4420
B C SH2 50 725 4421
SS C SH2 14 200 4438
SS C SH2 50 725 4439
A 209/C contact gauge, shortflexihose and 4 cylinders
B C SH4 14 200 4422
B C SH4 50 725 4423
SS C SH4 14 200 4440
SS C SH4 50 725 4441
A 209/C contact gauge, shortflexihose and 8 cylinders
B C SH8 14 200 4424
B C SH8 50 725 4425
SS C SH8 14 200 4442
SS C SH8 50 725 4443
A 209/C contact gauge, longflexihose and 2 cylinders
B C LH2 14 200 4426
B C LH2 50 725 4427
Specifications bar psi HiQ® code
SS C LH2 14 200 4444
SS C LH2 50 725 4445
A 209/C contact gauge, longflexihose and 4 cylinders
B C LH4 14 200 4428
B C LH4 50 725 4429
SS C LH4 14 200 4446
SS C LH4 50 725 4447
A 209/C contact gauge, longflexihose and 8 cylinders
B C LH8 14 200 4430
B C LH8 50 725 4431
SS C LH8 14 200 4448
SS C LH8 50 725 4449
A 209/RC residual gas outlet, contactgauge
B RC 14 200 5385
B RC 50 725 5386
SS RC 14 200 5405
SS RC 50 725 5406
A 209/RC residual gas outlet, contactgauge, coil and 2 cylinders
B RC C2 14 200 5387
B RC C2 50 725 5388
SS RC C2 14 200 5407
SS RC C2 50 725 5408
A 209/RC residual gas outlet, contactgauge, coil and 4 cylinders
B RC C4 14 200 5389
B RC C4 50 725 5390
SS RC C4 14 200 5409
SS RC C4 50 725 5410
A 209/RC residual gas outlet, contactgauge, coil and 8 cylinders
B RC C8 14 200 5391
B RC C8 50 725 5392
SS RC C8 14 200 5411
SS RC C8 50 725 5412
Specifications bar psi HiQ® code
A 209/RC residual gas outlet, contactgauge, short flexihose and 2 cylinders
B RC SH2 14 200 5393
B RC SH2 50 725 5394
SS RC SH2 14 200 5413
SS RC SH2 50 725 5414
A 209/RC residual gas outlet, contactgauge, short flexihose and 4 cylinders
B RC SH4 14 200 5395
B RC SH4 50 725 5396
SS RC SH4 14 200 5415
SS RC SH4 50 725 5416
A 209/RC residual gas outlet, contactgauge, short flexihose and 8cylinders
B RC SH8 14 200 5397
B RC SH8 50 725 5398
SS RC SH8 14 200 5417
SS RC SH8 50 725 5418
A 209/RC residual gas outlet, contactgauge, long flexihose and 2 cylinders
B RC LH2 14 200 5399
B RC LH2 50 725 5400
SS RC LH2 14 200 5419
SS RC LH2 50 725 5420
A 209/RC residual gas outlet, contactgauge, long flexihose and 4 cylinders
B RC LH4 14 200 5401
B RC LH4 50 725 5402
SS RC LH4 14 200 5421
SS RC LH4 50 725 5422
A 209/RC residual gas outlet, contactgauge, long flexihose and 8 cylinders
B RC LH8 14 200 5403
B RC LH8 50 725 5404
SS RC LH8 14 200 5423
SS RC LH8 50 725 5424
B = Brass
SS = Stainless steel
Cx = Coil and number of cylinders
SHx = Short flexihose and number of cylinders
LHx = Long flexihose and number of cylinders
C = Contact gauge
R = Residual gas outlet
RC = Residual gas outlet and contact gauge
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Points of use.Where all the action is.
The point of use is the second stage of acentral gas supply system.
Together with the gas panel it guarantees a
very stable outlet pressure and handles any
pressure changes that may be caused in the
system. When used together with a semi-auto-
matic gas manifold it handles the pressure
changes that are due to the changes from sec-
ondary to primary side.
The HiQ® REDLINE system is a modular system
which allows maximum freedom. Each point of
use can be individually equipped or stripped by
the functions “shut-off”, “pressure regulation”
and “flow regulation”. In this way, the point of
use at the work place can be updated at any
point to fit the present needs.
Note: HiQ® REDLINE points of use are delivered
with 6 or 12 mm tube fitting inlet con-
nection and 6 mm tube fitting outlet con-
nection.
Green group
Use nickel- and chromium plated brass
equipment.
Blue group
Use nickel- and chromium plated brass or
stainless steel equipment.
Orange group
Use stainless steel equipment.
Please see page 11 for detailed information
about the groups.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Points of use W 40. Wall design.The point of use is especially developed for specialty gases with high demands of purity, tightness and safety. The point of use is intendedfor wall-mounting with external gas supply line. Design F is a version with fixed pressure and flow meter.
Product name bar psi HiQ® code
W 40 A, brass n.a. n.a. 3247
W 40 A, stainless steel n.a. n.a. 3248
W 40 B, brass 0.1–1 1.5–15 3249
W 40 B, brass 0.5–6 8–85 3251
W 40 B, brass 1–10.5 15–150 3253
W 40 B, stainless steel 0.1–1 1.5–15 3250
W 40 B, stainless steel 0.5–6 8–85 3252
W 40 B, stainless steel 1–10.5 15–150 3254
W 40 C, brass 0.1–1 1.5–15 3255
W 40 C, brass 0.5–6 8–85 3257
W 40 C, brass 1–10.5 15–150 3259
W 40 C, stainless steel 0.1–1 1.5–15 3256
W 40 C, stainless steel 0.5–6 8–85 3258
W 40 C, stainless steel 1–10.5 15–150 3260
W 40 F, brass 3 45 5425
W 40 F, stainless steel 3 45 5426
Technical data
Max primary pressure 40 bar 550 psi
Secondary pressure 0.1–1 bar 1.5–15 psi
0.5–6 bar 8–85 psi
1–10.5 bar 15–150 psi
Pressure gauge scale –1–1.5 bar –14.5–21 psi
–1–10 bar –14.5–145 psi
–1–18 bar –14.5–260 psi
Max flow (nitrogen) 2 Nm3/h 700 SCFH
6 Nm3/h 2,100 SCFH
11 Nm3/h 3,850 SCFH
Material Brass, Ni/Cr plated
Stainless steel 316L
Operating temperature –20 – +70°C –4 – +158°F
53 100
120
154100
120
154100
120
Design A
Design B
Design C
All measurements in millimeters.
W40 C in the drawing is extra equipped.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Points of use B 40. Bench design.The point of use is especially developed for specialty gases with high demands of purity, tightness and safety. The point of use is intendedfor mounting on a bench e.g. a laboratory desk, with a gas supply line from below through the table stand. Design F is a version with fixedpressure and flow meter.
Product name bar psi HiQ® code
B 40 A, brass n.a. n.a. 3261
B 40 A, stainless steel n.a. n.a. 3262
B 40 B, brass 0.1–1 1.5–15 3263
B 40 B, brass 0.5–6 8–85 3265
B 40 B, brass 1–10.5 15–150 3267
B 40 B, stainless steel 0.1–1 1.5–15 3264
B 40 B, stainless steel 0.5–6 8–85 3266
B 40 B, stainless steel 1–10.5 15–150 3268
B 40 C, brass 0.1–1 1.5–15 3269
B 40 C, brass 0.5–6 8–85 3271
B 40 C, brass 1–10.5 15–150 3273
B 40 C, stainless steel 0.1–1 1.5–15 3270
B 40 C, stainless steel 0.5–6 8–85 3272
B 40 C, stainless steel 1–10.5 15–150 3274
B 40 F, brass 3 45 5427
B 40 F, stainless steel 3 45 5428
Technical data
Max primary pressure 40 bar 550 psi
Secondary pressure 0.1–1 bar 1.5–15 psi
0.5–6 bar 8–85 psi
1–10.5 bar 15–150 psi
Pressure gauge scale –1–1.5 bar –14.5–21 psi
–1–10 bar –14.5–145 psi
–1–18 bar –14.5–260 psi
Max flow (nitrogen) 2 Nm3/h 700 SCFH
6 Nm3/h 2,100 SCFH
11 Nm3/h 3,850 SCFH
Material Brass, Ni/Cr plated
Stainless steel 316L
Operating temperature –20 – +70°C –4 – +158°F
58
ø 50
~ 53
5823
5
~ 154
ø 50
160
~85
235
~ 154
ø 50
Design B
Design C
All measurements in millimeters.
Design A
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Points of use L 40. Fume cupboarddesign.The point of use is especially developed for specialty gases with high demands of purity, tightness and safety. The point of use is intendedfor mounting with gas supply line hidden behind a wall. Design F is a version with fixed pressure and flow meter.
Product name bar psi HiQ® code
L 40 A, brass n.a. n.a. 3275
L 40 A, stainless steel n.a. n.a. 3276
L 40 B, brass 0.1–1 1.5–15 3277
L 40 B, brass 0.5–6 8–85 3279
L 40 B, brass 1–10.5 15–150 3281
L 40 B, stainless steel 0.1–1 1.5–15 3278
L 40 B, stainless steel 0.5–6 8–85 3280
L 40 B, stainless steel 1–10.5 15–150 3282
L 40 C, brass 0.1–1 1.5–15 3283
L 40 C, brass 0.5–6 8–85 3285
L 40 C, brass 1–10.5 15–150 3287
L 40 C, stainless steel 0.1–1 1.5–15 3284
L 40 C, stainless steel 0.5–6 8–85 3286
L 40 C, stainless steel 1–10.5 15–150 3288
L 40 F, brass 3 45 5429
L 40 F, stainless steel 3 45 5430
Technical data
Max primary pressure 40 bar 550 psi
Secondary pressure 0.1–1 bar 1.5–15 psi
0.5–6 bar 8–85 psi
1–10.5 bar 15–150 psi
Pressure gauge scale –1–1.5 bar –14.5–21 psi
–1–10 bar –14.5–145 psi
–1–18 bar –14.5–260 psi
Max flow (nitrogen) 2 Nm3/h 700 SCFH
6 Nm3/h 2,100 SCFH
11 Nm3/h 3,850 SCFH
Material Brass, Ni/Cr plated
Stainless steel 316L
Operating temperature –20 – +70°C –4 – +158°F
~ 58~ 73
~ 159~ 53xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
~ 159~ 110~ 53
Design B
Design C
All measurements in millimeters.
Design A
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Points of use I 40X. Inset design.The point of use is especially developed for wall, bench or panel mounting, for inert, flammable and corrosive gases and gas mixtures.I 40 X is delivered with shut-off valve, regulator and needle valve. The n-version is without shut-off valve and s-version without needlevalve. I 40 sn is a version with shut-off valve, gauge & needle valve and the I 40 Xlh is an analysis version with shut-off valve, regulator &needle valve low hysteresis.
Product name bar psi HiQ® codeI 40 X, brass 0.1–1 1.5–15 5538
I 40 X, brass 0.5–4 8–60 5539
I 40 X, brass 0.5–10.5 8–150 5540
I 40 X, stainless steel 0.1–1 1.5–15 5551
I 40 X, stainless steel 0.5–4 8–60 5552
I 40 X, stainless steel 0.5–10.5 8–150 5553
I 40 Xn, brass 0.1–1 1.5–15 5541
I 40 Xn, brass 0.5–4 8–60 5542
I 40 Xn, brass 0.5–10.5 8–150 5543
I 40 Xn, stainless steel 0.1–1 1.5–15 5554
I 40 Xn, stainless steel 0.5–4 8–60 5555
I 40 Xn, stainless steel 0.5–10.5 8–150 5556
I 40 Xs, brass 0.1–1 1.5–15 5544
I 40 Xs, brass 0.5–4 8–60 5545
I 40 Xs, brass 0.5–10.5 8–150 5546
I 40 Xs, stainless steel 0.1–1 1.5–15 5557
I 40 Xs, stainless steel 0.5–4 8–60 5558
I 40 Xs, stainless steel 0.5–10.5 8–150 5559
I 40 sn, brass 0.1–1 1.5–15 5547
I 40 sn, brass 0.5–4 8–60 5548
I 40 sn, brass 0.5–10.5 8–150 5549
I 40 sn, stainless steel 0.1–1 1.5–15 5560
I 40 sn, stainless steel 0.5–4 8–60 5561
I 40 sn, stainless steel 0.5–10.5 8–150 5562
I 40 Xlh, brass 0.1–2.2 1.5–32 5550
I 40 Xlh, stainless steel 0.1–2.2 1.5–32 5563
Technical data
Max primary pressure 40 bar 550 psi
Secondary pressure 0.1–1 bar 1.5–15 psi
0.5–4 bar 8–60 psi
0.5–10.5 bar 8–150 psi
Pressure gauge scale 0–2.5 bar 0–40 psi
0–6 bar 0–90 psi psi
0–16 bar 0–230 psi psi
Material Brass, Ni/Cr plated
Stainless steel 316L
Operating temperature –20 – +70°C –4 – +158°F
85
112
42
3
~ 53
59
All measurements in millimeters.
I 40 X
4
3
2
1 Max flow
0 1 2 3
Flow, Nm3/h N2
Outlet pressure, bar
I 40 X 4
Max flow
987654321
10
0 2 4 86 10
Flow, Nm3/h N2
Outlet pressure, bar
I 40 X 10.5
11
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Cylinder regulators.When mobility and flexibility is the key.
Cylinder regulators are used to reduce thehigh pressure in the gas cylinder to a moremanageable pressure in the simplest of gasdelivery systems.
The cylinder regulator is equipped with a cylin-
der connection, a high pressure gauge to moni-
tor the content of the cylinder and a low
pressure gauge to monitor the adjustable sec-
ondary pressure. If there is a need for flow ad-
justments, the cylinder regulator is equipped
with a needle valve, otherwise it is equipped
with a shut-off valve.
Cylinder regulators are used when central gas
systems are not applicable. Such a case is mo-
bile calibrations for environmental applications
when maximum mobility is a prerequisite.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Cylinder regulators C 200/1.Single stage regulator.C 200/1 is a single stage cylinder regulator, especially suitable for specialty gases where demands on purity, tightness and safety are high. Asingle stage regulator is preferred where the primary pressure is fairly constant (e.g. for gases in liquid phase). C 200/1 can be plain or equip-ped with a shut-off valve (type A), a needle valve (type B) or equipped for purging of the high pressure side (type P) or cross-purge (type XP).
Technical data
Max primary pressure 230 bar 3,300 psi
Outlet pressure 0.2–3 bar 3–45 psi
0.5–6 bar 8–85 psi
2.5–14 bar 35–200 psi
2.5–50 bar 35–725 psi
10–200 bar 150–3,000 psi
Outlet gauge range –1–5 bar –14.5–75 psi
–1–10 bar –14.5–145 psi
0–25 bar 0–360 psi
0–80 bar 0–1,150 psi
0–315 bar 0–4,500 psi
Stability When the inlet pressure
drops by 10 bar, 145 psi
the outlet pressure rises
by less than 0.1 bar, 1.5 psi.
Connection Out = NPT ¼” female
Operating temperature –40 – +50°C –40 – +122°F
Weight 1.3 kg 2.9 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
Seating PCTFE
Product name bar psi HiQ® code
C 200/1, brass 0.2–3 3–45 4451
C 200/1, brass 0.5–6 8–85 5465
C 200/1, brass 2.5–14 35–200 5466
C 200/1, brass 2.5–50 35–725 4453
C 200/1, brass 10–200 150–3,000 4454
C 200/1, stainless steel 0.2–3 3–45 4455
C 200/1, stainless steel 0.5–6 8–85 5473
C 200/1, stainless steel 2.5–14 35–200 5474
C 200/1, stainless steel 2.5–50 35–725 4457
C 200/1, stainless steel 10–200 150–3,000 4458
C 200/1 A, brass 0.2–3 3–45 3100
C 200/1 A, brass 0.5–6 8–85 5467
C 200/1 A, brass 2.5–14 35–200 5468
C 200/1 A, brass 2.5–50 35–725 3102
C 200/1 A, brass 10–200 150–3,000 3103
C 200/1 A, stainless steel 0.2–3 3–45 3112
C 200/1 A, stainless steel 0.5–6 8–85 5475
C 200/1 A, stainless steel 2.5–14 35–200 5476
C 200/1 A, stainless steel 2.5–50 35–725 3114
C 200/1 A, stainless steel 10–200 150–3,000 3115
C 200/1 B, brass 0.2–3 3–45 3104
C 200/1 B, brass 0.5–6 8–85 5469
C 200/1 B, brass 2.5–14 35–200 5470
C 200/1 B, stainless steel 0.2–3 3–45 3116
C 200/1 B, stainless steel 0.5–6 8–85 5477
C 200/1 B, stainless steel 2.5–14 35–200 5478
C 200/1 P, brass 0.2–3 3–45 3108
C 200/1 P, brass 0.5–6 8–85 5471
C 200/1 P, brass 2.5–14 35–200 5472
C 200/1 P, brass 2.5–50 35–725 3110
C 200/1 P, brass 10–200 150–3,000 3111
C 200/1 P, stainless steel 0.2–3 3–45 3120
C 200/1 P, stainless steel 0.5–6 8–85 5479
C 200/1 P, stainless steel 2.5–14 35–200 5480
C 200/1 P, stainless steel 2.5–50 35–725 3122
C 200/1 P, stainless steel 10–200 150–3,000 3123
C 200/1 XP, brass 0.2–3 3–45 5564
C 200/1 XP, brass 0.5–6 8–85 5565
C 200/1 XP, brass 2.5–14 35–200 5566
C 200/1 XP, brass 2.5–50 35–725 5567
C 200/1 XP, brass 10–200 150–3,000 5568
C 200/1 XP, stainless steel 0.2–3 3–45 5569
C 200/1 XP, stainless steel 0.5–6 8–85 5570
C 200/1 XP, stainless steel 2.5–14 35–200 5571
C 200/1 XP, stainless steel 2.5–50 35–725 5572
C 200/1 XP, stainless steel 10–200 150–3,000 5573
All measurements in millimeters.
Type P. Drawings of other types available on request.
240
4
3
2
1
0 1 2 3 4 5 6 7Flow, Nm3/h N2
Outlet pressure, bar
C 200/1 3
Max flow
7 bar*
5 bar*
3 bar*
* Inlet pressure
29 bar*
4
6
2
8
0
Max flow
10
12
14
16
6 12 18 24 30
11 bar*
21 bar*
Flow, Nm3/h N2
Outlet pressure, bar
C 200/1 14
* Inlet pressure
60
50
40
30
20
10
0 10 20 30 40
81 bar*
101 bar*
61 bar*
Max flow
41 bar*
Flow, Nm3/h N2
Outlet pressure, bar
C 200/1 50
* Inlet pressure
13 bar*
2
3
1
4
0
Max flow
5
6
7
8
3 6 9 12 15
5 bar*
9 bar*
Flow, Nm3/h N2
Outlet pressure, bar
C 200/1 6
* Inlet pressure
120
100
80
60
40
20
10 20 30 40 50 60 700
230 bar*
161 bar*
81 bar*
Flow, Nm3/h N2
Outlet pressure, bar
C 200/1 200
* Inlet pressure
Max flow
120–140
C200/1
C200/1A
C200/1P
C200/1XP
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Cylinder regulators C 200/2.Two stage regulator.C 200/2 is a two-stage regulator made especially for the high demands on purity, safety and tightness that is necessary for specialty gases.Two stage regulators are preferred when a very stable secondary pressure is necessary and the primary pressure varies. C 200/2 can be plainor equipped with a shut-off valve (type A), a needle valve (type B) or equipped for purging of the high pressure side (type P).
Technical data
Primary pressure 7–230 bar 100–3,300 psi
Outlet pressure 0.2–3 bar 3–45 psi
0.5–6 bar 8–85 psi
1–10 bar 15–150 psi
Outlet gauge range –1–5 bar –14.5–75 psi
–1–10 bar –14.5–145 psi
–1–18 bar –14.5–260 psi
Stability When the inlet pressure
drops by 10 bar, 145 psi
the outlet pressure rises
by less than 0.01 bar, 0.1 psi.
Connection Out = NPT ¼” female
Operating temperature –40 – +50°C –40 – +122°F
Weight 3.0 kg 6.6 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
Seating PCTFE
Product name bar psi HiQ® code
C 200/2, brass 0.2–3 3–45 5481
C 200/2, brass 0.5–6 8–85 4460
C 200/2, brass 1–10.5 15–150 4461
C 200/2, stainless steel 0.2–3 3–45 5485
C 200/2, stainless steel 0.5–6 8–85 4463
C 200/2, stainless steel 1–10.5 15–150 4464
C 200/2 A, brass 0.2–3 3–45 5482
C 200/2 A, brass 0.5–6 8–85 3125
C 200/2 A, brass 1–10.5 15–150 3126
C 200/2 A, stainless steel 0.2–3 3–45 5486
C 200/2 A, stainless steel 0.5–6 8–85 3134
C 200/2 A, stainless steel 1–10.5 15–150 3135
C 200/2 B, brass 0.2–3 3–45 5483
C 200/2 B, brass 0.5–6 8–85 3128
C 200/2 B, brass 1–10.5 15–150 3129
C 200/2 B, stainless steel 0.2–3 3–45 5487
C 200/2 B, stainless steel 0.5–6 8–85 3137
C 200/2 B, stainless steel 1–10.5 15–150 3138
C 200/2 P, brass 0.2–3 3–45 5484
C 200/2 P, brass 0.5–6 8–85 3131
C 200/2 P, brass 1–10.5 15–150 3132
C 200/2 P, stainless steel 0.2–3 3–45 5488
C 200/2 P, stainless steel 0.5–6 8–85 3140
C 200/2 P, stainless steel 1–10.5 15–150 3141
All measurements in millimeters.
Type A. Drawings of other types available on request.
220
2.0
1.5
1.0
0.5
0 2 4 6 8 10 12
8 bar*
8 bar*
8 bar*
Max flow
2.5
3.0
3.5
4.0
Flow, Nm3/h N2Inlet pressure first stage, 17 bar.Outlet pressure first stage, 8 bar.* Inlet pressure
Outlet pressure, bar
C 200/2 3
8
6
4
2Max flow
17 bar*
17 bar*
17 bar*
0 2 4 6 8 10 12 14
Flow, Nm3/h N2
Outlet pressure, bar
C 200/2 6
Inlet pressure first stage, 35 bar.Outlet pressure first stage, 17 bar.* Inlet pressure
Max flow
17 bar*
17 bar*
17 bar*
17 bar*
987654321
10
0 5 3010 2015 25
Flow, Nm3/h N2
Outlet pressure, bar
C 200/2 10.5
Inlet pressure first stage, 35 bar.Outlet pressure first stage, 17 bar.* Inlet pressure
11199–211
2
C200/2
C200/2B
C200/2P
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Cylinder regulators C 200hv/2.Two stage regulator.C 200hv/2 is a two-stage regulator made especially for the high demands on purity, safety and tightness that is necessary for specialtygases. The regulator is designed to reduce inlet pressure to very low outlet pressures and be able to regulate low pressures very precise. Theregulator also have vacuum dosing capability down to 0.1 bar abs. C 200hv/2 can be plain or equipped with a shut-off valve (type A), aneedle valve (type B).
Technical data
Primary pressure 230 bar 3,300 psi
Outlet pressure 0.1–2 bar(a) 1.5–30 psi(a)
0.2–3 bar(a) 3–45 psi(a)
Outlet gauge range –1–1.5 bar –14.5–40 psi
–1–5 bar –14.5–75 psi
Connection Out = NPT ¼” female
Operating temperature –40 – +50°C –40 – +122°F
Weight 1.9 kg 4.2 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
Seating PCTFE
Product name bar(a) psi(a) HiQ® code
C 200hv/2, brass 0.1–2 1.5–30 5441
C 200hv/2, brass 0.2–3 3–45 5442
C 200hv/2, stainless steel 0.1–2 1.5–30 5447
C 200hv/2, stainless steel 0.2–3 3–45 5448
C 200hv/2 A, brass 0.1–2 1.5–30 5443
C 200hv/2 A, brass 0.2–3 3–45 5444
C 200hv/2 A, stainless steel 0.1–2 1.5–30 5449
C 200hv/2 A, stainless steel 0.2–3 3–45 5450
C 200hv/2 B, brass 0.1–2 1.5–30 5445
C 200hv/2 B, brass 0.2–3 3–45 5446
C 200hv/2 B, stainless steel 0.1–2 1.5–30 5451
C 200hv/2 B, stainless steel 0.2–3 3–45 5452
All measurements in millimeters.
Type A. Drawings of other types available on request.
199–211
220
1.2
0.8
0.4
00 0.5 1.0 1.5 2.0 2.5 3.0
2 bar*
1 bar*
1.6
2.0
2.4
Flow, Nm3/h N2
Outlet pressure, bar
C 200hv/2
C200hv/2
C200hv/2B
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE Cylinder regulators C 12hv/1.Single stage regulator.C 12hv/1 is a single stage cylinder regulator, especially suitable for specialty gases where demands on purity, tightness and safety are high.C 12hv/1 is suited for all low vapour pressure gases of all purities and gas mixtures, especially liquified gases. The regulator is designed toreduce inlet pressure to very low outlet pressures and be able to regulate low pressures very precise. The regulator also have vacuum dosingcapability down to 0.1 bar abs. C 12hv/1 can be plain or equipped with a shut-off valve (type A), a needle valve (type B).
Technical data
Primary pressure 12 bar 175 psi
Outlet pressure 0.1–2 bar(a) 1.5–30 psi(a)
0.2–3 bar(a) 3–45 psi(a)
Outlet gauge range –1–1.5 bar –14.5–40 psi
–1–5 bar –14.5–75 psi
Max flow (nitrogen) 5.8 Nm3/h 84 SCFH
Connection Out = NPT ¼” female
Operating temperature –40 – +50°C –40 – +122°F
Weight 1.5 kg 3.3 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
Seating PCTFE
Product name bar(a) psi(a) HiQ® code
C 12hv/1, brass 0.1–2 1.5–30 5453
C 12hv/1, brass 0.2–3 3–45 5454
C 12hv/1, stainless steel 0.1–2 1.5–30 5459
C 12hv/1, stainless steel 0.2–3 3–45 5460
C 12hv/1 A, brass 0.1–2 1.5–30 5455
C 12hv/1 A, brass 0.2–3 3–45 5456
C 12hv/1 A, stainless steel 0.1–2 1.5–30 5461
C 12hv/1 A, stainless steel 0.2–3 3–45 5462
C 12hv/1 B, brass 0.1–2 1.5–30 5457
C 12hv/1 B, brass 0.2–3 3–45 5458
C 12hv/1 B, stainless steel 0.1–2 1.5–30 5463
C 12hv/1 B, stainless steel 0.2–3 3–45 5464
All measurements in millimeters.
Type A. Drawings of other types available on request.
240
120–140
1.0
0.5
00 1 2 3 4 5 6
1.5
2.0
2.5
Flow, Nm3/h N2
Outlet pressure, bar
C 12hv/1
Max flow
C12hv/1
C12hv/1A
Gas name Chemical
formula
Gas panels Points of use
S200 S201 S202 S203 D204 A208 A209 W40 B40 L40 I40X
Acetylene C2H2 3)
Air, synthetic
Ammonia NH3 5)
Argon Ar
Arsine AsH3
Boron trichloride BCl3
Boron trifluoride BF3
1,3-Butadiene C4H6
n-Butane C4H10
iso-Butane C4H10
1-Butene C4H8
cis-2-Butene C4H8
trans-2-Butene C4H8
iso-Butene C4H8
Carbon dioxide CO2
Carbon monoxide CO
Carbonyl sulfide COS
Chlorine Cl2
Chlorine trifluoride ClF3
Cyanogen CNCN
Cyanogen chloride CNCl
Cyclopropane C3H6
Deuterium D2
Diborane B2H6
Dichlorosilane SiH2Cl2
Dimethylamine (CH3)2NH
Dimethyl ether C2H6O
2,2-Dimethylpropane C5H12
Ethane C2H6
Ethene C2H4
Ethylamine C2H5NH2
Ethyl chloride C2H5Cl
Ethylene oxide C2H4O
Fluorine6) F2
Germane GeH4
HiQ® Specialty gas program.Equipment & gas distribution systems.
The right HiQ® REDLINE choice
Cylinder regulators PoU Typical filling
pressure at
15 °C [bar]
Typical filling
pressure at
70 °F [psig]
Safety Material
recommen-
dation
Gas name
C200/1 C200/21) C200hv/2 C12hv1 Valve2)
16 250 F+ Brass4) Acetylene
200 2,400 Brass Air, synthetic
5) 5) 7.3 114 T, C, N SS Ammonia
150/200 2,640 A Brass Argon
13.5 205 F+, T+, N SS Arsine
1.1 4.4 T+, C SS Boron trichloride
60 1,600 T+, C SS Boron trifluoride
2 22 F+, Carc2, Muta2 Brass 1,3-Butadiene
1.75 16.3 F+ Brass n-Butane
2.6 31 F+ Brass iso-Butane
2.25 23.5 F+ Brass 1-Butene
1.5 13 F+ Brass cis-2-Butene
1.62 15 F+ Brass trans-2-Butene
2.3 24.3 F+ Brass iso-Butene
51 830 A Brass Carbon dioxide
100/150/200 1,660/2,000 F+, T, Tera1 Brass Carbon monoxide
9.6 85 F+, T SS Carbonyl sulfide
5.8 85.3 T, Xi, N SS Chlorine
1 0.9 C+, N SS Chlorine trifluoride
5 55 F+, T+ SS Cyanogen
19 260 T+ SS Cyanogen chloride
6 68 F+ Brass Cyclopropane
100 1,740 F+ Brass Deuterium
38 520 F+, T+ SS Diborane
1.3 9 F+, T, C SS Dichlorosilane
1.4 11 F+, Xn, Xi SS Dimethylamine
5 62.3 F+ Brass Dimethyl ether
1.2 7 F+ Brass 2,2-Dimethylpropane
33.8 544 F+ Brass Ethane
76 1,200 F+ Brass Ethene
1 5.3 F+, Xi SS Ethylamine
1 5.3 F+ SS Ethyl chloride
1.23 7 F+,T, Xi,Muta2,Carc2 SS Ethylene oxide
20 300 T+, C SS Fluorine6)
29 415 F+, T+ Brass Germane
Gas name Chemical
formulaGas panels Points of use
S200 S201 S202 S203 D204 A208 A209 W40 B40 L40 I40X
Helium He
Hydrogen H2
Hydrogen bromide HBr
Hydrogen chloride HCl
Hydrogen fluoride HF
Hydrogen sulfide H2S
Krypton Kr
Methane CH4
Methylamine CH3NH2
Methyl bromide CH3Br
Methyl chloride CH3Cl
Methyl fluoride CH3F
Methyl mercaptan CH3SH
Natural gas n.a.
Neon Ne
Nitric oxide NO
Nitrogen N2
Nitrogen dioxide NO2
Nitrogen trifluoride NF3
Nitrous oxide N2O
Octafluoropropane C3F8
Oxygen O2
Phosgene COCl2
Phosphine PH3
Propane C3H8
Propene C3H6
Propyne C3H4
R 11 Trichlorofluoromethane CFCl3
R 12 Dichlorodifluoromethane CF2Cl2
R 13 Chlorotrifluoromethane CF3Cl
R 13 b1 Bromotrifluoromethane CF3Br
R 14 Tetrafluoromethane CF4
R 21 Dichlorofluoromethane CHFCl2
R 22 Chlorodifluoromethane CHF2Cl
R 23 Trifluoromethane CHF3
HiQ® Specialty gas program.Equipment & gas distribution systems.
The right HiQ® REDLINE choice
Cylinder regulators PoU Typical filling
pressure at
15 °C [bar]
Typical filling
pressure at
70 °F [psig]
Safety Material
recommen-
dation
Gas name
C200/1 C200/21) C200hv/2 C12hv1 Valve2)
200 2,640 A Brass Helium
100/200 2,000/2,400 F+ Brass Hydrogen
19.3 320 C SS Hydrogen bromide
38 613 T, C SS Hydrogen chloride
0.9 0.9 T+,C SS Hydrogen fluoride
15.7 252 F+,T+, N SS Hydrogen sulfide
130 1,900 A Brass Krypton
100/150/200 2,000/2,400 F+ Brass Methane
2.5 29 F+, Xn, Xi SS Methylamine
1.6 13 T, Xi, N SS Methyl bromide
4.2 59 F+,Carc3, Xn SS Methyl chloride
38 538 F+ Brass Methyl fluoride
1.4 15 F+, T+ SS Methyl mercaptan
20–100 440–1,309 F+ Brass Natural gas
100/200 2,000/2,400 A Brass Neon
30/40 500 T+,C SS Nitric oxide
150/200 2,000/2,640 A Brass Nitrogen
1.0 0 T+,C SS Nitrogen dioxide
19 1,450 O, Xn SS Nitrogen trifluoride
45 745 O Brass Nitrous oxide
7.0 100 A Brass Octafluoropropane
150/200 2,000/2,640 O Brass Oxygen
1.3 10.7 T+ SS Phosgene
32 594 F+, T+ SS Phosphine
7.4 109 F+ Brass Propane
9.0 136 F+ Brass Propene
4.5 65 F+ Brass Propyne
0.8 13.4 N Brass R 11 Trichlorofluoromethane
5.0 70.2 N Brass R 12 Dichlorodifluoromethane
31 457 N Brass R 13 Chlorotrifluoromethane
14 189 N Brass R 13 b1 Bromotrifluoromethane
127 2,000 A Brass R 14 Tetrafluoromethane
1.0 4.0 N Brass R 21 Dichlorofluoromethane
8.0 121.4 N Brass R 22 Chlorodifluoromethane
37.5 635 A Brass R 23 Trifluoromethane
Gas name Chemical
formulaGas panels Points of use
S200 S201 S202 S203 D204 A208 A209 W40 B40 L40 I40X
R 32 Difluoromethane CH2F2
R114 1,2-Dichlorotetrafluorethane C2Cl2F4
R115 Chloropentafluoroethane C2ClF5
R116 Hexafluoroethane C2F6
R142b1-Chloro-1,1-difluoroethane C2H3ClF2
R152a1,1-Difluoroethane C2H4F2
Silane SiH4
Silicon tetrafluoride SiF4
Sulphur dioxide SO2
Sulphur hexafluoride SF6
Trimethylamine (CH3)3N
Tungsten hexafluoride WF6
Vinyl bromide C2H3Br
Vinyl chloride C2H3Cl
Vinyl methyl ether C3H6O
Xenon Xe
HiQ® Specialty gas program.Equipment & gas distribution systems.
The right HiQ® REDLINE choice
Footnotes1. Min. 7 bar primary pressure
2. Max. 50 bar primary pressure
3. W40 B Ac
4. Brass with <65% copper
5. Ammonia relief valve
6. Mixtures <10% F2
SafetyA = Asphyxiant
C = Corrosive
Carc1/2/3 = Carcinogenic category 1–3
F = Flammable
F+ = Extremely flammable
Muta1/2/3 = Mutagenic category 1–3
N = Environmentally harmful
O = Oxidizing
T = Toxic
T+ = Very toxic
Tera1/2/3 = Teratogenic category 1–3
Xn = Harmful
Xi = Irritating
Note!For toxic, harmful/irritating or flammable gas, Linde recommends that the
ventilation line shall end at a safe place outside the building or that it is
connected to separate ventilation.
Note!Gas panels aimed for flammable use shall have a non-return valve before
the regulator.
Note!Halocarbons damage the ozone layer of the atmosphere. Hence the use
of halocarbons is restricted and in some cases prohibited by local legisla-
tion. If a halocarbon can be substituted with an environmentally less
harmful substance, this shall be done.
4 = Standard equipment, all other requirements are special, please con-
tact your local supplier.
Cylinder regulators PoU Typical filling
pressure at
15 °C [bar]
Typical filling
pressure at
70 °F [psig]
Safety Material
recommen-
dation
Gas name
C200/1 C200/21) C200hv/2 C12hv1 Valve2)
12.6 160 F+ Brass R 32 Difluoromethane
1.5 12.6 N Brass R114 1,2-Dichlorotetrafluorethane
8 121.4 N Brass R115 Chloropentafluoroethane
27 430 A Brass R116 Hexafluoroethane
2.5 35 F+,N Brass R142b1-Chloro-1,1-difluoroethane
4.2 60 F+ Brass R152a1,1-Difluoroethane
14–80 150–1,205 F+ SS Silane
69 1,000 T,C SS Silicon tetrafluoride
2.7 34 T,C SS Sulfur dioxide
19 320 A Brass Sulfur hexafluoride
1.6 20 F+, Xn, Xi SS Trimethylamine
0.9 35 T SS Tungsten hexafluoride
1 6 F+,Carc1 SS Vinyl bromide
2.3 24.3 F+,Carc1 SS Vinyl chloride
1.5 11 F+ Brass Vinyl methyl ether
56 680 A Brass Xenon
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
CleanLine™.Points of use 6.0.
CleanLine™ is a series of points of useequipment and components for purities upto 6.0 (99.9999% pure).
Features:
• Unique design by Christian Bjørn
(the famous Danish designer)
• Combined pressure regulator, shut-off and
flow regulating valves
• Space saving design
• Easy and quick to mount
• Easy-grip handle
• Full metallic diaphragms in shut-off valve,
pressure regulator and flow regulating valve
• Built-in manometer with bar/psi scale
HiQ® Specialty gas program.Equipment & gas distribution systems.
CleanLine™ Points of use P 25. Panel mounting.The point of use is especially developed for specialty gases with high demands of purity, tightness and safety. The point of use is intendedfor panel mounting. There are six different models available where “s” stands for shut-off valve, “r” for pressure regulator and “f” for flowregulating valve.
Product name bar psi HiQ® code
P 25 s n.a. n.a. 5773
P 25 f n.a. n.a. 5774
P 25 r 0–1.5 bar 0–25 psi 5775
P 25 r 0–4 bar 0–60 psi 5776
P 25 r 0–10 bar 0–150 psi 5777
P 25 sr 0–1.5 bar 0–25 psi 5778
P 25 sr 0–4 bar 0–60 psi 5779
P 25 sr 0–10 bar 0–150 psi 5780
P 25 rf 0–1.5 bar 0–25 psi 5781
P 25 rf 0–4 bar 0–60 psi 5782
P 25 rf 0–10 bar 0–150 psi 5783
P 25 srf 0–1.5 bar 0–25 psi 5784
P 25 srf 0–4 bar 0–60 psi 5785
P 25 srf 0–10 bar 0–150 psi 5786
Product name Model Outlet codeCL-S, brass CleanLine™ straight outlet,NPT ¼” female 554
CL-S, stainless steel CleanLine™ straight outlet,NPT ¼” female 555
CL-45, brass CleanLine™ 45° outlet,NPT ¼” female 556
CL-45, stainless steel CleanLine™ 45° outlet,NPT ¼” female 557
Technical data
Max primary pressure 25 bar 360 psi
Secondary pressure 0–1.5 bar 0–25 psi
0–4 bar 0–60 psi
0–10 bar 0–150 psi
Pressure gauge scale –1–2.5 bar –14.5–36 psi
–1–6 bar –14.5–85 psi
–1–12 bar –14.5–174 psi
Operating temperature –20 – +70°C –4 – +158°F
Connections NPT ¼” female
Material
Housing Brass
(visible parts chemical Ni-plated)
Diaphragms
Stop valve Hastelloy®
Regulator Elgiloy®
Flow valve Haynes®
Seating PTFE
All measurements in millimeters.
Drawings of type s and f available on request.
C
B
D
79
Max 16Flow valve Stop valve
Pressureregulator
Panel
Type Dimensions [mm]B C D
sr 136 77.5 20.5
srf 136 77.5 20.5
r 109 48 20.5
rf 109 48 20.5
Gas: AirInlet pressure 20 barOutlet pressure 10 bar
12
10
8
6
4
2
00 20 40 60 80 100 120 140 160 180
Flow rate [l/min]
Out
letp
ress
ure
[bar
]
Typical flow curve for type srf.
P 25 srf
Design P srf
1/4"
NPT
1/2"
NPT
1/2"
NPS
M
6027
1/4"
NPT
1/4"
NPT
1/2"
NPT
1/2"
NPS
M
60
1/4" NPT
33
45°
CleanLine™ outlets
HiQ® Specialty gas program.Equipment & gas distribution systems.
CleanLine™ Points of use I 25. Inset design.The point of use is especially developed for specialty gases with high demands of purity, tightness and safety. The point of use is intendedfor wall mounting with built-in pipework. Model I 25X is equipped with internal inlet and external outlet. There are eight different modelsavailable where “s” stands for shut-off valve, “r” for pressure regulator and “f” for flow regulating valve.
Product name bar psi HiQ® code
I 25 s n.a. n.a. 5787
I 25 f n.a. n.a. 5788
I 25 r 0–1.5 bar 0–25 psi 5789
I 25 r 0–4 bar 0–60 psi 5790
I 25 r 0–10 bar 0–150 psi 5791
I 25 sr 0–1.5 bar 0–25 psi 5792
I 25 sr 0–4 bar 0–60 psi 5793
I 25 sr 0–10 bar 0–150 psi 5794
I 25 rf 0–1.5 bar 0–25 psi 5795
I 25 rf 0–4 bar 0–60 psi 5796
I 25 rf 0–10 bar 0–150 psi 5797
I 25 srf 0–1.5 bar 0–25 psi 5798
I 25 srf 0–4 bar 0–60 psi 5799
I 25 srf 0–10 bar 0–150 psi 5800
I 25X rf 0–1.5 bar 0–25 psi 5801
I 25X rf 0–4 bar 0–60 psi 5802
I 25X rf 0–10 bar 0–150 psi 5803
I 25X srf 0–1.5 bar 0–25 psi 5804
I 25X srf 0–4 bar 0–60 psi 5805
I 25X srf 0–10 bar 0–150 psi 5806
Product name Model Outlet codeCL-S, brass CleanLine™ straight outlet,NPT ¼” female 554
CL-S, stainless steel CleanLine™ straight outlet,NPT ¼” female 555
CL-45, brass CleanLine™ 45° outlet,NPT ¼” female 556
CL-45, stainless steel CleanLine™ 45° outlet,NPT ¼” female 557
Technical data
Max primary pressure 25 bar 360 psi
Secondary pressure 0–1.5 bar 0–25 psi
0–4 bar 0–60 psi
0–10 bar 0–150 psi
Pressure gauge scale –1–2.5 bar –14.5–36 psi
–1–6 bar –14.5–85 psi
–1–12 bar –14.5–174 psi
Operating temperature –20 – +70°C –4 – +158°F
Connections NPT ¼” female
Material
Housing Brass
(visible parts chemical Ni-plated)
Diaphragms
Stop valve Hastelloy®
Regulator Elgiloy®
Flow valve Haynes®
Seating PTFE
79
Max 52
Flow valve Stop valve
Pressureregulator
Panel
*Ø20
*Ø21
*27
OUT
IN
113
52
Ø52
Ø65
49
*Max dimensions of the tube fittings
Design I srf
All measurements in millimeters.
Other drawings available on request.
Gas: AirInlet pressure 20 barOutlet pressure 10 bar
12
10
8
6
4
2
00 20 40 60 80 100 120 140 160 180
Flow rate [l/min]
Out
letp
ress
ure
[bar
]
Typical flow curve for type srf.
I 25 srf1/
4"N
PT
1/2"
NPT
1/2"
NPS
M
6027
1/4"
NPT
1/4"
NPT
1/2"
NPT
1/2"
NPS
M
60
1/4" NPT
33
45°
CleanLine™ outlets
HiQ® Specialty gas program.Equipment & gas distribution systems.
CleanLine™ Points of use W 25. Wall mounting.The point of use is especially developed for specialty gases with high demands of purity, tightness and safety. The point of use is intendedfor wall mounting with exposed pipework. There are six different models available where “s” stands for shut-off valve, “r” for pressureregulator and “f” for flow regulating valve.
Product name bar psi HiQ® code
W 25 s n.a. n.a. 5807
W 25 f n.a. n.a. 5808
W 25 r 0–1.5 bar 0–25 psi 5809
W 25 r 0–4 bar 0–60 psi 5810
W 25 r 0–10 bar 0–150 psi 5811
W 25 sr 0–1.5 bar 0–25 psi 5812
W 25 sr 0–4 bar 0–60 psi 5813
W 25 sr 0–10 bar 0–150 psi 5814
W 25 rf 0–1.5 bar 0–25 psi 5815
W 25 rf 0–4 bar 0–60 psi 5816
W 25 rf 0–10 bar 0–150 psi 5817
W 25 srf 0–1.5 bar 0–25 psi 5818
W 25 srf 0–4 bar 0–60 psi 5819
W 25 srf 0–10 bar 0–150 psi 5820
Technical data
Max primary pressure 25 bar 360 psi
Secondary pressure 0–1.5 bar 0–25 psi
0–4 bar 0–60 psi
0–10 bar 0–150 psi
Pressure gauge scale –1–2.5 bar –14.5–36 psi
–1–6 bar –14.5–85 psi
–1–12 bar –14.5–174 psi
Operating temperature –20 – +70°C –4 – +158°F
Connections NPT ¼” female
Material
Housing Brass
(visible parts chemical Ni-plated)
Diaphragms
Stop valve Hastelloy®
Regulator Elgiloy®
Flow valve Haynes®
Seating PTFE
All measurements in millimeters.
Drawings of type s and f available on request.
B
C
Ø52
E
D
79
33
Flow valve Stop valve
Pressureregulator
Wall
Type Dimensions [mm]B C D E
sr 147 86 20.5 22.5
srf 147 86 20.5 22.5
r 123 61 20.5 26.5
rf 123 61 20.5 26.5
Gas: AirInlet pressure 20 barOutlet pressure 10 bar
12
10
8
6
4
2
00 20 40 60 80 100 120 140 160 180
Flow rate [l/min]
Out
letp
ress
ure
[bar
]
Typical flow curve for type srf.
W 25 srf
Design W srf
HiQ® Specialty gas program.Equipment & gas distribution systems.
CleanLine™ Points of use B 25.Bench/suspended mounting.The point of use is especially developed for specialty gases with high demands of purity, tightness and safety. The point of use is intendedfor mounting on a bench or in the ceiling. There are six different models available where “s” stands for shut-off valve, “r” for pressureregulator and “f” for flow regulating valve.
Product name bar psi HiQ® code
B 25 s n.a. n.a. 5821
B 25 f n.a. n.a. 5822
B 25 r 0–1.5 bar 0–25 psi 5823
B 25 r 0–4 bar 0–60 psi 5824
B 25 r 0–10 bar 0–150 psi 5825
B 25 sr 0–1.5 bar 0–25 psi 5826
B 25 sr 0–4 bar 0–60 psi 5827
B 25 sr 0–10 bar 0–150 psi 5828
B 25 rf 0–1.5 bar 0–25 psi 5829
B 25 rf 0–4 bar 0–60 psi 5830
B 25 rf 0–10 bar 0–150 psi 5831
B 25 srf 0–1.5 bar 0–25 psi 5832
B 25 srf 0–4 bar 0–60 psi 5833
B 25 srf 0–10 bar 0–150 psi 5834
Technical data
Max primary pressure 25 bar 360 psi
Secondary pressure 0–1.5 bar 0–25 psi
0–4 bar 0–60 psi
0–10 bar 0–150 psi
Pressure gauge scale –1–2.5 bar –14.5–36 psi
–1–6 bar –14.5–85 psi
–1–12 bar –14.5–174 psi
Operating temperature –20 – +70°C –4 – +158°F
Connections NPT ¼” female
Material
Housing Brass
(visible parts chemical Ni-plated)
Diaphragms
Stop valve Hastelloy®
Regulator Elgiloy®
Flow valve Haynes®
Seating PTFE
All measurements in millimeters.
Other drawings available on request.
79
12
34
Ø52
B
C
120
A
Ø22
D
Max
.32
Ceiling
Table
4
Max
.32
Flow valve Stop valve
Pressureregulator
Type Dimensions [mm]A B C D
sr 171 136 77.5 20.5
srf 171 136 77.5 20.5
r 144 109 48 20.5
rf 144 109 48 20.5
Gas: AirInlet pressure 20 barOutlet pressure 10 bar
12
10
8
6
4
2
00 20 40 60 80 100 120 140 160 180
Flow rate [l/min]
Out
letp
ress
ure
[bar
]
Typical flow curve for type srf.
B 25 srf
Design B srf
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Quick Connect.Points of use and outlets 5.0.
Quick Connect offers a set of point of useequipment that combines flexibility withhigh quality and safety.
Advantages for the end user:• Flexible and compact design increases size
of “working area”.
• Reduces downtime.
• Innovative and compact design.
• Combined flow valve and Quick Connect.
• Key system protects against undesired mix
of media, 11 keys are available.
• Clear media indication.
• Possibility of attaching additional equip-
ment: –flow meters, pressure regulators, etc.
• Non return valve in outlets protects against
contamination of equipment.
• Valve “locked” with no plug inserted.
• Gasket that seals between outlet and Quick
Connect, replaceable without disassembling
the Quick Connect.
Advantages for the architect & furnitureproducer:• Increased flexibility in laboratory design.
• Last minute determination of media
possible.
• Number of fittings can be reduced due to the
flexibility of the Quick Connect.
Advantages for the fitter:• Simple and rational installation.
• 6 different methods of installation.
• Last minute change of media possible (Prior
to start of use).
• Possibility to install additional Quick Connect
in the laboratory, using a model for exposed
piping.
Quick Connect equipment and accessories are delivered with labeling for different media according to standardEN13792:2002 or American recommendations. We also provide 3 versions that are not specified.Note: Equipment labeled for a specific media is delivered with a unique connection key to avoid undesired mix. When the
option “Not specified” or customer specified labeling is desired, please contact your local Linde representative for further
information.
Air Vacuum Oxygen NitrogenCarbondioxide
Hydrogen Argon HeliumNot
specifiedNot
specifiedNot
specified
EN13792:2002
Americanrecommendation
StandardMedia
Technical data
Max primary pressure 10 bar 145 psi
Connections NPT ¼” female
Operating temperature 0 – +60°C 32 – +140°F
Material
External Nickel plated brass,
Stainless steel, EPDM rubber
Media wetted parts Stainless steel, brass, PVDF
Seals Viton®
HiQ® Specialty gas program.Equipment & gas distribution systems.
Quick Connect Points of use. Connection points.Quick Connect connection points are delivered in four different versions: inset design (I), panel mounted with concealed piping (BE) andpanel mounted with exposed piping (SE). For bench mounted/suspended mounting (B) see next spread. The wall bracket (WB) is intendedfor use with the SE models when front side mounting is desired of the Quick Connect connection points. For technical data see page 89.
Product name Media HiQ® code
QC–W I air 5835
QC–W I vacuum 5836
QC–W I oxygen 5837
QC–W I nitrogen 5838
QC–W I carbon dioxide 5839
QC–W I hydrogen 5840
QC–W I argon 5841
QC–W I helium 5842
QC–W I not specified 5843
QC–W I not specified 5844
QC–W I not specified 5845
QC–W BE air 5846
QC–W BE vacuum 5847
QC–W BE oxygen 5848
QC–W BE nitrogen 5849
QC–W BE carbon dioxide 5850
QC–W BE hydrogen 5851
QC–W BE argon 5852
QC–W BE helium 5853
QC–W BE not specified 5854
QC–W BE not specified 5855
QC–W BE not specified 5856
QC–W SE air 5857
QC–W SE vacuum 5858
QC–W SE oxygen 5859
QC–W SE nitrogen 5860
QC–W SE carbon dioxide 5861
QC–W SE hydrogen 5862
QC–W SE argon 5863
QC–W SE helium 5864
QC–W SE not specified 5865
QC–W SE not specified 5866
QC–W SE not specified 5867
QC–WB (wall bracket) all media 5868
Product name Media HiQ® code
QC–W I air 5869
QC–W I vacuum 5870
QC–W I oxygen 5871
QC–W I nitrogen 5872
QC–W I carbon dioxide 5873
QC–W I hydrogen 5874
QC–W I argon 5875
QC–W I helium 5876
QC–W I not specified 5877
QC–W I not specified 5878
QC–W I not specified 5879
QC–W BE air 5880
QC–W BE vacuum 5881
QC–W BE oxygen 5882
QC–W BE nitrogen 5883
QC–W BE carbon dioxide 5884
QC–W BE hydrogen 5885
QC–W BE argon 5886
QC–W BE helium 5887
QC–W BE not specified 5888
QC–W BE not specified 5889
QC–W BE not specified 5890
QC–W SE air 5891
QC–W SE vacuum 5892
QC–W SE oxygen 5893
QC–W SE nitrogen 5894
QC–W SE carbon dioxide 5895
QC–W SE hydrogen 5896
QC–W SE argon 5897
QC–W SE helium 5898
QC–W SE not specified 5899
QC–W SE not specified 5900
QC–W SE not specified 5901
QC–WB (wall bracket) all media 5868
Media labeling according to standard EN13792:2002 Media labeling according to American recommendations
Mounting hole
Ø51
Ø25
Ø72
30
Ø57
49 Ø75
Panel Max 30
Outer diameterquick connect
34
45º
M3 X 0.5 Thread depthmin. 6mm
Ø23
12
4.5
Ø52
52
12.5 Center inlet(Exposed piping)
Mounting holes(Shown from the backside)
Built in (QC-W I)
Front side mounted (QC-W BE and SE)
All measurements in millimeters.
Outer diameterquick connect
1.5
1.5
Ø44
.5
Ø52
52
12.5 Center inlet(Exposed piping)
Ø25
45
Panel Max 12
Ø75 Mounting hole
Back side mounted (QC-W BE and SE)
Wall bracket (for QC-W SE)
Inlet pressure
0
50
100
150
200
250
300
014.5
2129
343.5
458
572.5
687
7101.5
8116
9130.5
10145
barpsi
Flow
[l/m
in]
Flow regulation curve
QC-W I
QC-W BE
QC-W SE
Ø52
68
29.5 Center inlet(Exposed piping)
Ø52
Ø20 Ø30
16Ø6
(2Pc
s.)
Wall/panel
HiQ® Specialty gas program.Equipment & gas distribution systems.
Quick Connect Points of use. Connection points.For bench mounted or suspended mounting. Technical data see page 89.
Product name Media HiQ® code
QC–B air 5902
QC–B vacuum 5903
QC–B oxygen 5904
QC–B nitrogen 5905
QC–B carbon dioxide 5906
QC–B hydrogen 5907
QC–B argon 5908
QC–B helium 5909
QC–B not specified 5910
QC–B not specified 5911
QC–B not specified 5912
Product name Media HiQ® code
QC–B air 5913
QC–B vacuum 5914
QC–B oxygen 5915
QC–B nitrogen 5916
QC–B carbon dioxide 5917
QC–B hydrogen 5918
QC–B argon 5919
QC–B helium 5920
QC–B not specified 5921
QC–B not specified 5922
QC–B not specified 5923
Media labeling according to standard EN13792:2002 Media labeling according to American recommendations
87
52
120
Ø52
Max
.32
12Ø
22
Table/ceiling
ContourColumn
13 28
18
Mounting hole
5
Bench mounted
All measurements in millimeters.
QC-B
Inlet pressure
0
50
100
150
200
250
300
014.5
2129
343.5
458
572.5
687
7101.5
8116
9130.5
10145
barpsi
Flow
[l/m
in]
Flow regulation curve
HiQ® Specialty gas program.Equipment & gas distribution systems.
Quick Connect Outlets.Quick Connect outlets are delivered in four different versions: 90° outlet with serrated hose nozzle (ON), 90° outlet with ¼” NPT female (OF),straight outlet with ¼” NPT male (OS) and a 1.5 m stainless steel wire braded PTFE hose. The hose is equipped with ¼” NPSM femaleconnection in one end and ¼” NPT male in the other end (OHM). One version with ¼” NPSM female in both ends (OHF) also available. Thehose plugs in to Quick Connect via the straight outlet (OS). Other lengths of hoses on request. Models ON, OF and OS includes a non-returnvalve. For technical data see page 89.
Product name Media Outlet code
QC–ON air 521
QC–ON vacuum 522
QC–ON oxygen 523
QC–ON nitrogen 524
QC–ON carbon dioxide 525
QC–ON hydrogen 526
QC–ON argon 527
QC–ON helium 528
QC–ON not specified 529
QC–ON not specified 530
QC–ON not specified 531
QC–OF air 532
QC–OF vacuum 533
QC–OF oxygen 534
QC–OF nitrogen 535
QC–OF carbon dioxide 536
QC–OF hydrogen 537
QC–OF argon 538
QC–OF helium 539
QC–OF not specified 540
QC–OF not specified 541
QC–OF not specified 542
QC–OS air 543
QC–OS vacuum 544
QC–OS oxygen 545
QC–OS nitrogen 546
QC–OS carbon dioxide 547
QC–OS hydrogen 548
QC–OS argon 549
QC–OS helium 550
QC–OS not specified 551
QC–OS not specified 552
QC–OS not specified 553
QC–OHM all media 564
QC–OHF all media 565
Product name Media Outlet code
QC–ON air 607
QC–ON vacuum 608
QC–ON oxygen 609
QC–ON nitrogen 610
QC–ON carbon dioxide 611
QC–ON hydrogen 612
QC–ON argon 613
QC–ON helium 614
QC–ON not specified 615
QC–ON not specified 616
QC–ON not specified 617
QC–OF air 618
QC–OF vacuum 619
QC–OF oxygen 620
QC–OF nitrogen 621
QC–OF carbon dioxide 622
QC–OF hydrogen 623
QC–OF argon 624
QC–OF helium 625
QC–OF not specified 626
QC–OF not specified 627
QC–OF not specified 628
QC–OS air 629
QC–OS vacuum 630
QC–OS oxygen 631
QC–OS nitrogen 632
QC–OS carbon dioxide 633
QC–OS hydrogen 634
QC–OS argon 635
QC–OS helium 636
QC–OS not specified 637
QC–OS not specified 638
QC–OS not specified 639
QC–OHM all media 564
QC–OHF all media 565
Media labeling according to standard EN13792:2002 Media labeling according to American recommendations
Ø22
49
Ø10
39
44
90° with serrated hose nozzle
90° with ¼” NPT female
All measurements in millimeters.
Straight outlet with ¼” NPT male
Hose outlet with ¼” NPT male
39
49
Ø22
18
5
QC-ON
QC-OF
QC-OS
QC-OH
HiQ® Specialty gas program.Equipment & gas distribution systems.
Quick Connect Outlets. Regulator.Quick Connect pressure regulator is used when pressure control is needed at the point of use. The Quick Connect pressure regulator isdelivered in two pressure intervals and it is provided with a scale expressed in bar or psi. The regulator is delivered with a non-return valve.For other combinations than mentioned below (e.g. scale expressed in kPa or media labeling according to EN standard with scale in psi)please contact your local Linde representative. For technical data see page 89.
Product Pressure range/ Media Outlet
name scale in bar code
QC–OR 0–5 air 566
QC–OR 0–10 air 567
QC–OR 0–5 oxygen 568
QC–OR 0–10 oxygen 569
QC–OR 0–5 nitrogen 570
QC–OR 0–10 nitrogen 571
QC–OR 0–5 carbon dioxide 572
QC–OR 0–10 carbon dioxide 573
QC–OR 0–5 hydrogen 574
QC–OR 0–10 hydrogen 575
QC–OR 0–5 argon 576
QC–OR 0–10 argon 577
QC–OR 0–5 helium 578
QC–OR 0–10 helium 579
QC–OR 0–5 not specified 580
QC–OR 0–10 not specified 581
QC–OR 0–5 not specified 582
QC–OR 0–10 not specified 583
QC–OR 0–5 not specified 584
QC–OR 0–10 not specified 585
Media labeling according to standard EN13792:2002 Media labeling according to American recommendations
Product Pressure range/ Media Outlet
name scale in psi code
QC–OR 0–75 air 652
QC–OR 0–150 air 653
QC–OR 0–75 oxygen 654
QC–OR 0–150 oxygen 655
QC–OR 0–75 nitrogen 656
QC–OR 0–150 nitrogen 657
QC–OR 0–75 carbon dioxide 658
QC–OR 0–150 carbon dioxide 659
QC–OR 0–75 hydrogen 660
QC–OR 0–150 hydrogen 661
QC–OR 0–75 argon 662
QC–OR 0–150 argon 663
QC–OR 0–75 helium 664
QC–OR 0–150 helium 665
QC–OR 0–75 not specified 666
QC–OR 0–150 not specified 667
QC–OR 0–75 not specified 668
QC–OR 0–150 not specified 669
QC–OR 0–75 not specified 670
QC–OR 0–150 not specified 671
30
Ø39
26
48
Ø42
101
40
All measurements in millimeters.
QC-OR
HiQ® Specialty gas program.Equipment & gas distribution systems.
Quick Connect Outlets. Flow meter.Quick Connect flow meter is used when indication of flow is needed at the point of use. The Quick Connect flow meter is delivered in threeflow intervals and is provided with a scale expressed in l/min. The flow meter is delivered with a non-return valve. For other media thanmentioned below please contact your local Linde representative. For technical data see page 89.
Product Flow range, Media Outlet
name l/min code
QC–OFM 0–6 air 586
QC–OFM 0–15 air 587
QC–OFM 0–30 air 588
QC–OFM 0–6 oxygen 589
QC–OFM 0–15 oxygen 590
QC–OFM 0–30 oxygen 591
QC–OFM 0–6 nitrogen 592
QC–OFM 0–15 nitrogen 593
QC–OFM 0–30 nitrogen 594
QC–OFM 0–6 carbon dioxide 595
QC–OFM 0–15 carbon dioxide 596
QC–OFM 0–30 carbon dioxide 597
QC–OFM 0–6 hydrogen 598
QC–OFM 0–15 hydrogen 599
QC–OFM 0–30 hydrogen 600
QC–OFM 0–6 argon 601
QC–OFM 0–15 argon 602
QC–OFM 0–30 argon 603
QC–OFM 0–6 helium 604
QC–OFM 0–15 helium 605
QC–OFM 0–30 helium 606
Media labeling according to standard EN13792:2002 Media labeling according to American recommendations
Product Flow range, Media Outlet
name l/min code
QC–OFM 0–6 air 672
QC–OFM 0–15 air 673
QC–OFM 0–30 air 674
QC–OFM 0–6 oxygen 675
QC–OFM 0–15 oxygen 676
QC–OFM 0–30 oxygen 677
QC–OFM 0–6 nitrogen 678
QC–OFM 0–15 nitrogen 679
QC–OFM 0–30 nitrogen 680
QC–OFM 0–6 carbon dioxide 681
QC–OFM 0–15 carbon dioxide 682
QC–OFM 0–30 carbon dioxide 683
QC–OFM 0–6 hydrogen 684
QC–OFM 0–15 hydrogen 685
QC–OFM 0–30 hydrogen 686
QC–OFM 0–6 argon 687
QC–OFM 0–15 argon 688
QC–OFM 0–30 argon 689
QC–OFM 0–6 helium 690
QC–OFM 0–15 helium 691
QC–OFM 0–30 helium 692
Ø30
Ø8
85
130
77
36
Ø25
Ø29
All measurements in millimeters.
QC-OFM
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
BASELINE™.Cylinder regulators 5.0
Regulators are used to reduce the highpressure in the gas cylinder to a moremanageable pressure in the simplest of gasdelivery systems.
The cylinder regulator is equipped with a cylin-
der connection, a high pressure gauge to moni-
tor the content of the cylinder and a low
pressure gauge to monitor the adjustable sec-
ondary pressure. If there is a need for flow ad-
justments the cylinder regulator is equipped
with a needle valve, otherwise it is equipped
with a shut-off valve.
BASELINE™ cylinder regulators are the entry
point into the world of specialty gas equipment.
They are meant for more stable operation than
industrial equipment can provide, at a competi-
tive price. Typical applications are gas and liq-
uid chromatography, carrier gases, zero and
span calibration gases, high purity chamber
pressurization, liquified hydrocarbon gas control
and control of cryogenic gases.
HiQ® Specialty gas program.Equipment & gas distribution systems.
BASELINE™ C 106/1. Six-port single stage cylinderregulator.The C 106/1 cylinder regulators are intended for primary pressure control of noncorrosive, high purity or liquefied gases or for applicationswhere minor fluctuations in outlet pressure due to diminishing inlet supply can be tolerated. For ultra high purity or corrosive gases use thestainless steel version. C 106/1 can be plain or equipped with a diaphragm valve (type A) or a needle valve (type B).
Technical data
Max primary pressure 210 bar 3,000 psi
Outlet pressure 0–1 bar 0–15 psi
0–3.5 bar 0–50 psi
0–7 bar 0–100 psi
0–10.5 bar 0–150 psi
0–17 bar 0–250 psi
0–35 bar 0–500 psi
Outlet gauge range –2–2 bar –30–30 psi
–2–7 bar –30–100 psi
–2–14 bar –30–200 psi
0–28 bar 0–400 psi
0–70 bar 0–1,000 psi
Connection Out = NPT ¼” female
Operating temperature –40 – +60°C –40 – +140°F
Weight 1.4 kg 3.1 lb
Material
Housing Brass, Cr plated
Stainless steel 316L
Seals PTFE
Membrane Stainless steel 316L
Seating PTFE
Product name bar psi Outlet code
C 106/1, brass 0–1 0–15 5724
C 106/1, brass 0–3.5 0–50 5725
C 106/1, brass 0–7 0–100 5726
C 106/1, brass 0–10.5 0–150 5727
C 106/1, brass 0–17 0–250 5728
C 106/1, brass 0–35 0–500 5729
C 106/1, stainless steel 0–1 0–15 5730
C 106/1, stainless steel 0–3.5 0–50 5731
C 106/1, stainless steel 0–7 0–100 5732
C 106/1, stainless steel 0–10.5 0–150 5733
C 106/1, stainless steel 0–17 0–250 5734
C 106/1, stainless steel 0–35 0–500 5735
C 106/1 A, brass 0–1 0–15 5736
C 106/1 A, brass 0–3.5 0–50 5737
C 106/1 A, brass 0–7 0–100 5738
C 106/1 A, brass 0–10.5 0–150 5739
C 106/1 A, brass 0–17 0–250 5740
C 106/1 A, brass 0–35 0–500 5741
C 106/1 A, stainless steel 0–1 0–15 5742
C 106/1 A, stainless steel 0–3.5 0–50 5743
C 106/1 A, stainless steel 0–7 0–100 5744
C 106/1 A, stainless steel 0–10.5 0–150 5745
C 106/1 A, stainless steel 0–17 0–250 5746
C 106/1 A, stainless steel 0–35 0–500 5747
C 106/1 B, brass 0–1 0–15 5748
C 106/1 B, brass 0–3.5 0–50 5749
C 106/1 B, brass 0–7 0–100 5750
C 106/1 B, brass 0–10.5 0–150 5751
C 106/1 B, brass 0–17 0–250 5752
C 106/1 B, brass 0–35 0–500 5753
C 106/1 B, stainless steel 0–1 0–15 5754
C 106/1 B, stainless steel 0–3.5 0–50 5755
C 106/1 B, stainless steel 0–7 0–100 5756
C 106/1 B, stainless steel 0–10.5 0–150 5757
C 106/1 B, stainless steel 0–17 0–250 5758
C 106/1 B, stainless steel 0–35 0–500 5759
All measurements in millimeters.
Drawings of other types available on request.FLOW RATE – SCFM (LPM) N2
10(283)
40(1133)
35(991)
30(850)
25(708)
20(566)
15(425)
5(142)
2000 PSIG (138 BAR)INLET PRESSURE
500 PSIG (35 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
500 PSIG (35 BAR)INLET PRESSURE
OU
TLET
PRES
SURE
-PS
IG(B
AR)
500(34.5)
450(31)
400(27.6)
350(24.1)
300(20.7)
250(17.2)
200(13.8)
150(10.3)
100(6.9)
50(3.4)
90(6.2)
80(5.5)
70(4.8)
60(4.1)
50(3.4)
40(2.8)
30(2.0)
20(1.4)
10(0.7)
100(6.9)
OU
TLET
PRES
SURE
-PS
IG(B
AR)
10(283)
20(566)
15(425)
5(142)
500 PSIG (35 BAR)INLET PRESSURE
500 PSIG (35 BAR)INLET PRESSURE
500 PSIG (35 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
200 PSIG (13.8 BAR)INLET PRESSURE
200 PSIG (13.8 BAR)INLET PRESSURE
200 PSIG (13.8 BAR)INLET PRESSURE
C 106/1 single stage regulator
1000 PSIG (138 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
INLE TAUX .
INL E T
60° 60°
60°
Ø53
Ø50
10.5
117
Ø44
? ???? ?? ?
? ? ??? ? ? ?
AUX .
OUTLE
T
60°
60°
INLE
TG AU
G E 60°
O UT L E T
OUT LE T
G AUG E
C 106/1B
HiQ® Specialty gas program.Equipment & gas distribution systems.
BASELINE™ C 106X/1. Six-port single stage extra highpressure cylinder regulator.The C 106X/1 high pressure cylinder regulators are intended for primary pressure control of noncorrosive, high purity or liquefied gases or forapplications where minor fluctuations in outlet pressure due to diminishing inlet supply can be tolerated. For ultra high purity or corrosivegases use the stainless steel version. C 106X/1 can be plain or equipped with a diaphragm valve (type A) or a needle valve (type B).
Technical data
Max primary pressure 310 bar 4,500 psi
Outlet pressure 0–3.5 bar 0–50 psi
0–7 bar 0–100 psi
0–10.5 bar 0–150 psi
0–17 bar 0–250 psi
0–35 bar 0–500 psi
Outlet gauge range –2–7 bar –30–100 psi
–2–14 bar –30–200 psi
0–28 bar 0–400 psi
0–70 bar 0–1,000 psi
Connection Out = NPT ¼” female
Operating temperature –40 – +60°C –40 – +140°F
Weight 1.4 kg 3.1 lb
Material
Housing Brass, Cr plated
Stainless steel 316L
Seals PTFE
Membrane Stainless steel 316L
Seating PCTFE
Product name bar psi HiQ® code
C 106X/1, brass 0–3.5 0–50 5574
C 106X/1, brass 0–7 0–100 5575
C 106X/1, brass 0–10.5 0–150 5576
C 106X/1, brass 0–17 0–250 5577
C 106X/1, brass 0–35 0–500 5578
C 106X/1, stainless steel 0–3.5 0–50 5579
C 106X/1, stainless steel 0–7 0–100 5580
C 106X/1, stainless steel 0–10.5 0–150 5581
C 106X/1, stainless steel 0–17 0–250 5582
C 106X/1, stainless steel 0–35 0–500 5583
C 106X/1 A, brass 0–3.5 0–50 5584
C 106X/1 A, brass 0–7 0–100 5585
C 106X/1 A, brass 0–10.5 0–150 5586
C 106X/1 A, brass 0–17 0–250 5587
C 106X/1 A, brass 0–35 0–500 5588
C 106X/1 A, stainless steel 0–3.5 0–50 5589
C 106X/1 A, stainless steel 0–7 0–100 5590
C 106X/1 A, stainless steel 0–10.5 0–150 5591
C 106X/1 A, stainless steel 0–17 0–250 5592
C 106X/1 A, stainless steel 0–35 0–500 5593
C 106X/1 B, brass 0–3.5 0–50 5594
C 106X/1 B, brass 0–7 0–100 5595
C 106X/1 B, brass 0–10.5 0–150 5596
C 106X/1 B, brass 0–17 0–250 5597
C 106X/1 B, brass 0–35 0–500 5598
C 106X/1 B, stainless steel 0–3.5 0–50 5599
C 106X/1 B, stainless steel 0–7 0–100 5600
C 106X/1 B, stainless steel 0–10.5 0–150 5601
C 106X/1 B, stainless steel 0–17 0–250 5602
C 106X/1 B, stainless steel 0–35 0–500 5603
FLOW RATE – SCFM (LPM) N2
10(283)
40(1133)
35(991)
30(850)
25(708)
20(566)
15(425)
5(142)
2000 PSIG (138 BAR)INLET PRESSURE
500 PSIG (35 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
500 PSIG (35 BAR)INLET PRESSURE
OU
TLET
PRES
SURE
-PS
IG(B
AR)
500(34.5)
450(31)
400(27.6)
350(24.1)
300(20.7)
250(17.2)
200(13.8)
150(10.3)
100(6.9)
50(3.4)
90(6.2)
80(5.5)
70(4.8)
60(4.1)
50(3.4)
40(2.8)
30(2.0)
20(1.4)
10(0.7)
100(6.9)
OU
TLET
PRES
SURE
-PS
IG(B
AR)
10(283)
20(566)
15(425)
5(142)
500 PSIG (35 BAR)INLET PRESSURE
500 PSIG (35 BAR)INLET PRESSURE
500 PSIG (35 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
200 PSIG (13.8 BAR)INLET PRESSURE
200 PSIG (13.8 BAR)INLET PRESSURE
200 PSIG (13.8 BAR)INLET PRESSURE
C 106/1 single stage regulator
1000 PSIG (138 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
INLE TAUX .
INL E T
60° 60°
60°
Ø53
Ø50
10.5
117
Ø44
? ???? ?? ?
? ? ??? ? ? ?
AUX .
OUTLE
T
60°
60°
INLE
TG AU
G E 60°
O UT L E T
OUT LE T
G AUG E
C 106X/1B
All measurements in millimeters.
Drawings of other types available on request.
HiQ® Specialty gas program.Equipment & gas distribution systems.
BASELINE™ C 106/2. Six-port two stage cylinderregulator.The C 106/2 cylinder regulators are are intended for primary pressure control of noncorrosive, high purity or liquefied gases for applicationsrequiring constant pressure control and delivery regardless of supply pressure variations. For ultra high purity or corrosive gases use thestainless steel version. C 106/2 can be plain or equipped with a diaphragm valve (type A) or a needle valve (type B).
Technical data
Max primary pressure 210 bar 3,000 psi
Outlet pressure 0–1 bar 0–15 psi
0–3.5 bar 0–50 psi
0–7 bar 0–100 psi
0–10.5 bar 0–150 psi
0–17 bar 0–250 psi
Outlet gauge range –2–2 bar –30–30 psi
–2–7 bar –30–100 psi
–2–14 bar –30–200 psi
0–28 bar 0–400 psi
Connection Out = NPT ¼” female
Operating temperature –40 – +60°C –40 – +140°F
Weight 2 kg 4.4 lb
Material
Housing Brass, Cr plated
Stainless steel 316L
Seals PTFE
Membrane Stainless steel 316L
Seating PTFE
Product name bar psi HiQ® code
C 106/2, brass 0–1 0–15 5628
C 106/2, brass 0–3.5 0–50 5629
C 106/2, brass 0–7 0–100 5630
C 106/2, brass 0–10.5 0–150 5631
C 106/2, brass 0–17 0–250 5632
C 106/2, stainless steel 0–1 0–15 5633
C 106/2, stainless steel 0–3.5 0–50 5634
C 106/2, stainless steel 0–7 0–100 5635
C 106/2, stainless steel 0–10.5 0–150 5636
C 106/2, stainless steel 0–17 0–250 5637
C 106/2 A, brass 0–1 0–15 5638
C 106/2 A, brass 0–3.5 0–50 5639
C 106/2 A, brass 0–7 0–100 5640
C 106/2 A, brass 0–10.5 0–150 5641
C 106/2 A, brass 0–17 0–250 5642
C 106/2 A, stainless steel 0–1 0–15 5643
C 106/2 A, stainless steel 0–3.5 0–50 5644
C 106/2 A, stainless steel 0–7 0–100 5645
C 106/2 A, stainless steel 0–10.5 0–150 5646
C 106/2 A, stainless steel 0–17 0–250 5647
C 106/2 B, brass 0–1 0–15 5648
C 106/2 B, brass 0–3.5 0–50 5649
C 106/2 B, brass 0–7 0–100 5650
C 106/2 B, brass 0–10.5 0–150 5651
C 106/2 B, brass 0–17 0–250 5652
C 106/2 B, stainless steel 0–1 0–15 5653
C 106/2 B, stainless steel 0–3.5 0–50 5654
C 106/2 B, stainless steel 0–7 0–100 5655
C 106/2 B, stainless steel 0–10.5 0–150 5656
C 106/2 B, stainless steel 0–17 0–250 5657
All measurements in millimeters.
Drawings of other types available on request.
5(142)
10(283)
15(425)
20(566)
1(28.3)
2(56.6)
3(85)
4(113)
25(1.7)
50(3.4)
75(5.2)
100(6.9)
125(8.6)
150(10.3)
175(12.0)
200(13.8)
225(15.5)
250(17.2)
2(.13)
4(.27)
6(.41)
8(.55)
10(.69)
12(.83)
14(.97)
16(1.1)
18(1.24)
20(1.38)
FLO W - SCFM (LPM)
OU
TLET
PRES
SURE
-PS
IG(B
AR)
FLO W - SCFM (LPM )
OU
TLET
PRES
SURE
-PS
IG(B
AR)
2000 PSIGINLET PRESSURE
200 PSIGINLET PRESSURE
500 PSIGINLET PRESSURE
2000 PSIGINLET PRESSURE
500 PSIGINLET PRESSURE
2000 PSIGINLET PRESSURE
200 PSIGINLET PRESSURE
500 PSIGINLET PRESSURE
2000 PSIGINLET PRESSURE
200 PSIGINLET PRESSURE 500 PSIG
INLET PRESSURE
2000 PSIGINLET PRESSURE200 PSIG
INLET PRESSURE 500 PSIGINLET PRESSURE
C 106/2 dual stage regulator
196
82.5
Ø44
.5
60°AUX .
INL E T
60°
G AUG E
60°
60°
OUT LE T
G AUG E INLE
T
O UT L E T
60° INLE T
60°
AUX .
Ø53
Ø50
? ???? ?? ?
? ? ??? ? ? ?
C 106/2B
HiQ® Specialty gas program.Equipment & gas distribution systems.
BASELINE™ C 106X/2. Six-port two stage extra highpressure cylinder regulator.The C 106X/2 high pressure cylinder regulators are are intended for primary pressure control of noncorrosive, high purity or liquefied gasesfor applications requiring constant pressure control and delivery regardless of supply pressure variations. For ultra high purity or corrosivegases use the stainless steel version. C 106X/2 can be plain or equipped with a diaphragm valve (type A) or a needle valve (type B).
Technical data
Max primary pressure 310 bar 4,500 psi
Outlet pressure 0–1 bar 0–15 psi
0–3.5 bar 0–50 psi
0–7 bar 0–100 psi
0–10.5 bar 0–150 psi
0–17 bar 0–250 psi
Outlet gauge range –2–2 bar –30–30 psi
–2–7 bar –30–100 psi
–2–14 bar –30–200 psi
0–28 bar 0–400 psi
Connection Out = NPT ¼” female
Operating temperature –40 – +60°C –40 – +140°F
Weight 2 kg 4.4 lb
Material
Housing Brass, Cr plated
Stainless steel 316L
Seals PTFE
Membrane Stainless steel 316L
Seating PCTFE
Product name bar psi HiQ® code
C 106X/2, brass 0–1 0–15 5658
C 106X/2, brass 0–3.5 0–50 5659
C 106X/2, brass 0–7 0–100 5660
C 106X/2, brass 0–10.5 0–150 5661
C 106X/2, brass 0–17 0–250 5662
C 106X/2, stainless steel 0–1 0–15 5663
C 106X/2, stainless steel 0–3.5 0–50 5664
C 106X/2, stainless steel 0–7 0–100 5665
C 106X/2, stainless steel 0–10.5 0–150 5666
C 106X/2, stainless steel 0–17 0–250 5667
C 106X/2 A, brass 0–1 0–15 5668
C 106X/2 A, brass 0–3.5 0–50 5669
C 106X/2 A, brass 0–7 0–100 5670
C 106X/2 A, brass 0–10.5 0–150 5671
C 106X/2 A, brass 0–17 0–250 5672
C 106X/2 A, stainless steel 0–1 0–15 5673
C 106X/2 A, stainless steel 0–3.5 0–50 5674
C 106X/2 A, stainless steel 0–7 0–100 5675
C 106X/2 A, stainless steel 0–10.5 0–150 5676
C 106X/2 A, stainless steel 0–17 0–250 5677
C 106X/2 B, brass 0–1 0–15 5678
C 106X/2 B, brass 0–3.5 0–50 5679
C 106X/2 B, brass 0–7 0–100 5680
C 106X/2 B, brass 0–10.5 0–150 5681
C 106X/2 B, brass 0–17 0–250 5682
C 106X/2 B, stainless steel 0–1 0–15 5683
C 106X/2 B, stainless steel 0–3.5 0–50 5684
C 106X/2 B, stainless steel 0–7 0–100 5685
C 106X/2 B, stainless steel 0–10.5 0–150 5686
C 106X/2 B, stainless steel 0–17 0–250 5687
All measurements in millimeters.
Drawings of other types available on request.
5(142)
10(283)
15(425)
20(566)
1(28.3)
2(56.6)
3(85)
4(113)
25(1.7)
50(3.4)
75(5.2)
100(6.9)
125(8.6)
150(10.3)
175(12.0)
200(13.8)
225(15.5)
250(17.2)
2(.13)
4(.27)
6(.41)
8(.55)
10(.69)
12(.83)
14(.97)
16(1.1)
18(1.24)
20(1.38)
FLO W - SCFM (LPM)
OU
TLET
PRES
SURE
-PS
IG(B
AR)
FLO W - SCFM (LPM )
OU
TLET
PRES
SURE
-PS
IG(B
AR)
2000 PSIGINLET PRESSURE
200 PSIGINLET PRESSURE
500 PSIGINLET PRESSURE
2000 PSIGINLET PRESSURE
500 PSIGINLET PRESSURE
2000 PSIGINLET PRESSURE
200 PSIGINLET PRESSURE
500 PSIGINLET PRESSURE
2000 PSIGINLET PRESSURE
200 PSIGINLET PRESSURE 500 PSIG
INLET PRESSURE
2000 PSIGINLET PRESSURE200 PSIG
INLET PRESSURE 500 PSIGINLET PRESSURE
C 106/2 dual stage regulator
196
82.5
Ø44
.5
60°AUX .
INL E T
60°
G AUG E
60°
60°
OUT LE T
G AUG E INLE
T
O UT L E T
60° INLE T
60°
AUX .
Ø53
Ø50
? ???? ?? ?
? ? ??? ? ? ?
C 106X/2B
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Components.
The integrated equipment presented so farin this catalog consists of various compo-nents. This chapter is intended forconstructing central gas systems or otherequipment requiring information onindividual components.
Though it is possible to construct gas panels
and points of use from this equipment, it is
neither cost efficient nor advisable due to
quality problems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE R 200/1. Single stage regulator.The R 200/1 is a high pressure regulator with a high flow rate capacity. The regulator is available in brass or stainless steel for the control ofboth corrosive and non-corrosive gases.
Technical data
Max primary pressure 230 bar 3,300 psi
Outlet pressure 0.2–3 bar 3–45 psi
0.5–6 bar 8–85 psi
2.5–14 bar 35–200 psi
2.5–50 bar 35–725 psi
10–200 bar 150–3,000 psi
Outlet gauge range –1–5 bar –14.5–75 psi
–1–10 bar –14.5–145 psi
0–25 bar 0–360 psi
0–80 bar 0–1,150 psi
0–315 bar 0–4,500 psi
Stability When the inlet pressure
drops by 10 bar, 145 psi
the outlet pressure rises
by less than 0.1 bar, 1.5 psi.
Connections NPT ¼” female
Operating temperature –40 – +50°C –40 – +122°F
Weight 1.3 kg 2.9 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
Seating PCTFE
Product name bar psi HiQ® code
R 200/1, brass 0.2–3 3–40 3334
R 200/1, stainless steel, 0.2–3 3–40 3335
R 200/1, brass 0.5–6 8–85 5489
R 200/1, stainless steel, 0.5–6 8–85 5489
R 200/1, brass 2.5–14 35–200 3336
R 200/1, stainless steel 2.5–14 35–200 3337
R 200/1, brass 2.5–50 35–700 3338
R 200/1, stainless steel 2.5–50 35–700 3339
R 200/1, brass 10–200 150–3,000 3340
R 200/1, stainless steel 10–200 150–3,000 3341
All measurements in millimeters.
40
ø50
120–140
19
R 200/1
4
3
2
1
0 1 2 3 4 5 6 7Flow, Nm3/h N2
Outlet pressure, bar
R 200/1 3
Max flow
7 bar*
5 bar*
3 bar*
* Inlet pressure
29 bar*
4
6
2
8
0
Max flow
10
12
14
16
6 12 18 24 30
11 bar*
21 bar*
Flow, Nm3/h N2
Outlet pressure, bar
R 200/1 14
* Inlet pressure
60
50
40
30
20
10
0 10 20 30 40 50 60 70 80 90
101 bar*
81 bar*
61 bar*
Max flow41 bar*
Flow, Nm3/h N2
Outlet pressure, bar
R 200/1 50
* Inlet pressure
13 bar*
2
3
1
4
0
Max flow
5
6
7
8
3 6 9 12 15
5 bar*
9 bar*
Flow, Nm3/h N2
Outlet pressure, bar
R 200/1 6
* Inlet pressure
120
100
80
60
40
20
10 20 30 40 50 60 700
230 bar*
161 bar*
81 bar*
Flow, Nm3/h N2
Outlet pressure, bar
R 200/1 200
* Inlet pressure
Max flow
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE R 200/F. Single stage regulator.For the control of a broad range of specialty gases in applications where a fixed outlet pressure is required.
Technical data
Max primary pressure 230 bar 3,300 psi
Outlet pressure 3 bar 45 psi
10.5 bar 150 psi
Non-adjustable
Outlet gauge range –1–5 bar –14.5–75 psi
–1–16 bar –14.5–230 psi
Stability When the inlet pressure
drops by 10 bar, 145 psi
the outlet pressure rises
by less than 0.1 bar, 1.5 psi.
Connections NPT ¼” female
Operating temperature –40 – +50°C –40 – +122°F
Weight 1.3 kg 2.9 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
Seating PCTFE
Product name bar psi HiQ® code
R 200/F, brass 3 45 3348
R 200/F, stainless steel 3 45 3349
R 200/F, brass 10.5 150 3350
R 200/F, stainless steel 10.5 150 3351
All measurements in millimeters.
40
ø50
120–140
19
R 200/F
Max flow
8 bar*
4
3
2
1
0 1 2 3 4 5 6 7Flow, Nm3/h N2
Outlet pressure, bar
R 200/F 3
* Inlet pressure
Max flow
25 bar*
14
12
10
6
8
4
2
0 5 10 15 20 25Flow, Nm3/h N2
Outlet pressure, bar
R 200/F 10.5
* Inlet pressure
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE R 200/2. Two stage regulator.The R 200/2 is a high pressure regulator with the pressure reduced in two stages to fulfill the highest demands regarding stability of outletpressure. The regulator is available in brass or stainless steel for the control of both corrosive and non-corrosive gases.
Technical data
Primary pressure 7–230 bar 100–3,300 psi
Outlet pressure 0.2–3 bar 3–45 psi
0.5–6 bar 8–85 psi
1–10.5 bar 15–150 psi
Outlet gauge range –1–5 bar –14.5–75 psi
–1–10 bar –14.5–145 psi
–1–16 bar –14.5–230 psi
Stability When the inlet pressure
drops by 10 bar, 145 psi
the outlet pressure rises
by less than 0.01 bar, 0.1 psi.
Connection Out = NPT ¼” female
Operating temperature –40 – +50°C –40 – +122°F
Weight 3.0 kg 6.6 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
Seating PCTFE
Product name bar psi HiQ® code
R 200/2, brass 0.2–3 3–45 3342
R 200/2, stainless steel 0.2–3 3–45 3343
R 200/2, brass 0.5–6 8–85 3344
R 200/2, stainless steel 0.5–6 8–85 3345
R 200/2, brass 1–10.5 15–200 3346
R 200/2, stainless steel 1–10.5 15–200 3347
All measurements in millimeters.
4
3
2
1Max flow
8 bar*
8 bar*
8 bar*
0 1 2 3 4 5 6 7
Flow, Nm3/h N2
Outlet pressure, bar
R 200/2 3
Inlet pressure first stage, 17 bar.Outlet pressure first stage, 8 bar.* Inlet pressure
8
6
4
2Max flow
17 bar*
17 bar*
17 bar*
0 2 4 6 8 10 12 14
Flow, Nm3/h N2
Outlet pressure, bar
R 200/2 6
Inlet pressure first stage, 35 bar.Outlet pressure first stage, 17 bar.* Inlet pressure
Max flow
17 bar*
17 bar*
17 bar*
17 bar*
987654321
10
0 5 3010 2015 25
Flow, Nm3/h N2
Outlet pressure, bar
R 200/2 10.5
Inlet pressure first stage, 35 bar.Outlet pressure first stage, 17 bar.* Inlet pressure
11
199–211
40 98
ø50
R 200/2
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE R 200hv/2. Two stage regulator.R 200hv/2 is a two-stage regulator made especially for the high demands on purity, safety and tightness that is necessary for specialtygases. The regulator is designed to reduce inlet pressure to very low outlet pressures and be able to regulate low pressures very precise. Theregulator also have vacuum dosing capability down to 0.1 bar abs.
Technical data
Primary pressure 230 bar 3,300 psi
Outlet pressure 0.1–2 bar(a) 1.5–30 psi(a)
0.2–3 bar(a) 3–45 psi(a)
Outlet gauge range –1–1.5 bar –14.5–40 psi
–1–5 bar –14.5–75 psi
Connection Out = NPT ¼” female
Operating temperature –40 – +50°C –40 – +122°F
Weight 1.9 kg 4.2 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
Seating PCTFE
Product name bar(a) psi(a) HiQ® code
R 200hv/2, brass 0.1–2 1.5–30 5491
R 200hv/2, stainless steel 0.1–2 1.5–30 5492
R 200hv/2, brass 0.2–3 3–45 5493
R 200hv/2, stainless steel 0.2–3 3–45 5495
All measurements in millimeters.
199–211
2
1.2
0.8
0.4
00 0.5 1.0 1.5 2.0 2.5 3.0
2 bar*
1 bar*
1.6
2.0
2.4
Flow, Nm3/h N2
Outlet pressure, bar
R 200hv/2
R 200hv/2
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE R 40. Single stage regulator.Pressure regulator intended for use as a second pressure regulating step in a central gas supply system. It is especially developed for puregases and gas mixtures. The membrane is in Hastelloy® so that diffusion into the system is minimized. Modular design and three differentoutlet pressure ranges offer great flexibility for point of use applications.
Product name bar psi HiQ® code
R 40, brass 0.1–1 1.5–15 3352
R 40, stainless steel 0.1–1 1.5–15 3353
R 40, brass 0.5–6 8–85 3354
R 40, stainless steel 0.5–6 8–85 3355
R 40, brass 1–10.5 15–150 3356
R 40, stainless steel 1–10.5 15–150 3357
Technical data
Max primary pressure 40 bar 550 psi
Outlet pressure 0.1–1 bar 1.5–15 psi
0.5–6 bar 8–85 psi
1–10.5 bar 15–150 psi
Outlet gauge range 0–2.5 bar 0–40 psi
0–6 bar 0–90 psi
0–16 bar 0–250 psi
Connections G ⅜” female / G ¼” female
Operating temperature –20 – +70°C –4 – +158°F
Weight 0.8 kg 1.8 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
Seating Kalrez®
All measurements in millimeters.
~ 110
~10
3
ø42
ø50
~ 85
R 40
Outlet pressure, bar
R 40 6
2.0
1.0
3.0
4.0
5.0
6.0
0 2.0 4.0 106.0 8.0
9 bar*
9 bar*
9 bar* Max flow
Flow, Nm3/h N2* Inlet pressure
Outlet pressure, bar
R 40 10.5
6
4
2
3
0
78
9
10
5 10 25
5
15 20
21 bar*
21 bar*
21 bar* Max flow
Flow, Nm3/h N2* Inlet pressure
0.4
0.3
0.2
0.1
0
0.5
0.6
0.7
0.8
0.5 1.0 1.5 2.0 2.5 3.0
4 bar*
4 bar*
Max flow4 bar*
Outlet pressure, bar
Flow, Nm3/h N2
R 40 1
* Inlet pressure
0.9
1.0
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE R 12. Single stage regulator.Pressure regulator intended for use as a second pressure regulating step in a central gas supply system. It is especially developed forapplications where it is essential with a very stable outlet pressure.
Product name bar psi HiQ® code
R 12, brass 0.1–1 1.5–15 3358
R 12, stainless steel 0.1–1 1.5–15 3359
R 12, brass 0.2–3 3–45 3360
R 12, stainless steel 0.2–3 3–45 3361
Technical data
Max primary pressure 12 bar 175 psi
Outlet pressure 0.1–1 bar 1.5–15 psi
0.2–3 bar 3–45 psi
Outlet gauge range –1–5 bar 0–75 psi
Connections G ⅜” female / G ¼” female
Operating temperature –20 – +70°C –4 – +158°F
Weight 0.8 kg 1.8 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
Seating Kalrez®
All measurements in millimeters.
~ 110
~10
3
ø42
ø50
~ 85
R 12
1.0
0.5
00 1 2 3 4 5 6
1.5
2.0
2.5
Flow, Nm3/h N2
Outlet pressure, bar
R 12
Max flow
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE R 12hv/1. Single stage regulator.Pressure regulator intended for use as a second pressure regulating step in a central gas supply system. R 12hv/1 is suited for all low vapourpressure gases of all purities and gas mixtures, especially liquified gases. The regulator is designed to reduce inlet pressure to very lowoutlet pressures and be able to regulate low pressures very precise. The regulator also have vacuum dosing capability down to 0.1 bar abs.
Product name bar(a) psi(a) HiQ® code
R 12hv/1, brass 0.1–2 1.5–30 5499
R 12hv/1, stainless steel 0.1–2 1.5–30 5496
R 12hv/1, brass 0.2–3 3–45 5497
R 12hv/1, stainless steel 0.2–3 3–45 5498
Technical data
Max primary pressure 12 bar 175 psi
Outlet pressure 0.1–2 bar(a) 1.5–30 psi(a)
0.2–3 bar(a) 3–45 psi(a)
Outlet gauge range –1–5 bar 0–75 psi
Connections NPT ¼” female
Operating temperature –20 – +70°C –4 – +158°F
Weight 0.8 kg 1.8 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PVDF PCTFE
Membrane Hastelloy®
Seating Kalrez®
All measurements in millimeters.
~ 110
~10
3
ø42
ø50
~ 85
R 12hv/1
0.1
0.9
0.8
0.70
1.0
1.1
1.2
0.1 0.2 0.3 0.4 0.5 0.6
hysteresis
12 bar*close
open
Outlet pressure, bar
Flow, Nm3/h N2
R 12hv/1 1
* Inlet pressure
2.9
2.8
2.7
2.60
3.0
3.1
3.2
0.1 0.2 0.3 0.4 0.5 0.6
hysteresis
12 bar*close
open
Outlet pressure, bar
Flow, Nm3/h N2
R 12hv/1 3
* Inlet pressure
HiQ® Specialty gas program.Equipment & gas distribution systems.
BASELINE™ R 104/1. Four-port single stage lineregulator 5.0.The R 104/1 regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied gases or as point of use pressurecontrol in high purity gas distribution systems up to purities 5.0. For high purity or corrosive gases use the stainless steel version. R 104/1can be plain or equipped with a diaphragm valve (type A) or a needle valve (type B).
Technical data
Max primary pressure 210 bar 3,000 psi
Outlet pressure 0–1 bar 0–15 psi
0–3.5 bar 0–50 psi
0–7 bar 0–100 psi
0–10.5 bar 0–150 psi
0–17 bar 0–250 psi
0–35 bar 0–500 psi
Outlet gauge range –2–2 bar –30–30 psi
–2–7 bar –30–100 psi
–2–14 bar –30–200 psi
0–28 bar 0–400 psi
0–70 bar 0–1,000 psi
Connection Out = NPT ¼” female
Operating temperature –40 – +60°C –40 – +140°F
Weight 0.8 kg 1.7 lb
Material
Housing Brass, Cr plated
Stainless steel 316L
Seals PTFE
Membrane Stainless steel 316L
Seating PTFE
Product name bar psi HiQ® code
R 104/1, brass 0–1 0–15 5688
R 104/1, brass 0–3.5 0–50 5689
R 104/1, brass 0–7 0–100 5690
R 104/1, brass 0–10.5 0–150 5691
R 104/1, brass 0–17 0–250 5692
R 104/1, brass 0–35 0–500 5693
R 104/1, stainless steel 0–1 0–15 5694
R 104/1, stainless steel 0–3.5 0–50 5695
R 104/1, stainless steel 0–7 0–100 5696
R 104/1, stainless steel 0–10.5 0–150 5697
R 104/1, stainless steel 0–17 0–250 5698
R 104/1, stainless steel 0–35 0–500 5699
R 104/1 A, brass 0–1 0–15 5700
R 104/1 A, brass 0–3.5 0–50 5701
R 104/1 A, brass 0–7 0–100 5702
R 104/1 A, brass 0–10.5 0–150 5703
R 104/1 A, brass 0–17 0–250 5704
R 104/1 A, brass 0–35 0–500 5705
R 104/1 A, stainless steel 0–1 0–15 5706
R 104/1 A, stainless steel 0–3.5 0–50 5707
R 104/1 A, stainless steel 0–7 0–100 5708
R 104/1 A, stainless steel 0–10.5 0–150 5709
R 104/1 A, stainless steel 0–17 0–250 5710
R 104/1 A, stainless steel 0–35 0–500 5711
R 104/1 B, brass 0–1 0–15 5712
R 104/1 B, brass 0–3.5 0–50 5713
R 104/1 B, brass 0–7 0–100 5714
R 104/1 B, brass 0–10.5 0–150 5715
R 104/1 B, brass 0–17 0–250 5716
R 104/1 B, brass 0–35 0–500 5717
R 104/1 B, stainless steel 0–1 0–15 5718
R 104/1 B, stainless steel 0–3.5 0–50 5719
R 104/1 B, stainless steel 0–7 0–100 5720
R 104/1 B, stainless steel 0–10.5 0–150 5721
R 104/1 B, stainless steel 0–17 0–250 5722
R 104/1 B, stainless steel 0–35 0–500 5723
All measurements in millimeters.
Drawings of other types available on request.FLOW RATE – SCFM (LPM) N2
10(283)
40(1133)
35(991)
30(850)
25(708)
20(566)
15(425)
5(142)
2000 PSIG (138 BAR)INLET PRESSURE
500 PSIG (35 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
500 PSIG (35 BAR)INLET PRESSURE
OU
TLET
PRES
SURE
-PS
IG(B
AR)
500(34.5)
450(31)
400(27.6)
350(24.1)
300(20.7)
250(17.2)
200(13.8)
150(10.3)
100(6.9)
50(3.4)
90(6.2)
80(5.5)
70(4.8)
60(4.1)
50(3.4)
40(2.8)
30(2.0)
20(1.4)
10(0.7)
100(6.9)
OU
TLET
PRES
SURE
-PS
IG(B
AR)
10(283)
20(566)
15(425)
5(142)
500 PSIG (35 BAR)INLET PRESSURE
500 PSIG (35 BAR)INLET PRESSURE
500 PSIG (35 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
200 PSIG (13.8 BAR)INLET PRESSURE
200 PSIG (13.8 BAR)INLET PRESSURE
200 PSIG (13.8 BAR)INLET PRESSURE
R 104/1 single stage regulator
1000 PSIG (138 BAR)INLET PRESSURE
2000 PSIG (138 BAR)INLET PRESSURE
O U T L E T
GAU
GE
OUT
LET
INL E
TAU
X.
90°
90°
Ø53
Ø50
10.5
117
Ø44INL E T
90°
? ?? ? ?? ??
? ??? ? ?? ?
R 104/1
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE V 40. Diaphragm valve.Valve intended for use as a shut-off-valve in a central gas supply system. It is preferably used together with pressure regulator R 12 or R 40.Equipped with “click-function” to enhance safety. BE is back entry version and SE is side entry version.
Product name bar psi HiQ® code
V 40 BE, brass n.a. n.a. 3364
V 40 BE, stainless steel n.a. n.a. 3365
V 40 SE, brass n.a. n.a. 3366
V 40 SE, stainless steel n.a. n.a. 3367
Technical data
Max primary pressure 40 bar 550 psi
Connections
Design BE In = NPT ¼” female
Out = NPT ⅜” maleDesign SE In = NPT ⅜” female
Out = NPT ⅜” maleOperating temperature –30 – +70°C –22 – +158°F
Weight 0.6 kg 1.3 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PCTFE
Diaphragm Hastelloy® C
All measurements in millimeters.
~ 74
ø42 50
0
2.01.8
1.61.41.21.00.80.60.4
0.2
02 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34
10 bar* 20 bar* 50 bar*
Flow, Nm3/h N2* Inlet pressure
Pressure loss, bar
V 40 BE
V 40 SE25
104~ 74
ø42
Design V 40 BE
Design V 40 SE
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE V 50. Flow valve.Diaphragm regulating valve for use in applications where a precise regulation of flow is desired. BE is back entry version and SE is side entryversion.
Product name bar psi HiQ® code
V 50 BE, brass n.a. n.a. 3368
V 50 BE, stainless steel n.a. n.a. 3369
V 50 SE, brass n.a. n.a. 3370
V 50 SE, stainless steel n.a. n.a. 3371
Technical data
Max primary pressure 50 bar 700 psi
Connections NPT ¼” female
Operating temperature –30 – +70°C –22 – +158°F
Weight 0.26 kg 0.57 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals Hardened stainless steel cone
Diaphragm Hastelloy® Elgiloy®
All measurements in millimeters.
~85
19
ø24
0.4
0.2
0
0.6
0.8
1.0
1 2 3 4 5 6 7 8
0.1 bar*
0.2 bar*
0.4 bar*0.8 bar*
Flow, Nm3/h N2
* Inlet pressure Number of handle turns
V 50 BE
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® REDLINE V 200. Shut-off valve.Valve intended for use as a shut-off valve in a central gas supply system. Equipped with “click-function” to enhance safety.
Product name bar psi HiQ® code
V 200, brass n.a. n.a. 3372
V 200, stainless steel n.a. n.a. 3373
Technical data
Max primary pressure 200 bar 3,000 psi
Connections NPT ¼” female
Operating temperature –30 – +70°C –22 – +158°F
Weight 0.26 kg 0.57 lb
Material
Housing Brass, Ni/Cr plated
Stainless steel 316L
Seals PCTFE
Diaphragm Hastelloy® Elgiloy®
All measurements in millimeters.
~85
ø24
19
0
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
02 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34
10 bar*
100 bar*
20 bar*50 bar*
Flow, Nm3/h N2* Inlet pressure
Pressure loss, bar
V 200
HiQ® Specialty gas program.Equipment & gas distribution systems.
V 1315. Needle valve.Needle valve V 1315 is designed for minute flow control of very small flows. Wetted parts are either in stainless steel or Teflon®.The brass version is designed for a max. primary pressure of 200 bar and the stainless steel version of the valve up to max. 350 bar.
Product name bar psi HiQ® code
V 1315, brass n.a. n.a. 3384
V 1315, stainless steel n.a. n.a. 3385
Technical data
Max primary pressure 200/350 bar 3,000/5,000 psi
Connections NPT ¼” compression fitting
Operating temperature –54 – +200°C –65 – +400°F
Material
Housing Brass/Stainless steel
Seals Teflon®
Stem Stainless steel
60
83
13
Cv
Num
ber
ofva
lve
hand
letu
rns
.002 .004 .006 .008 .010 .012 .014 .016 .018 .020 .022 .024 .026
2
0
4
6
8
10
12
14
16
18
V 1315
All measurements in millimeters.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Special equipment.
From time to time the needs on theinstallation components may be veryspecific.
Such demands can be unlimited scalability,
handling of extremely high pressures or very
small components. These products not fitting
into our standardized equipment lines are found
in this chapter. The compilation of products rep-
resents Linde’s choice of innovative and high
quality solutions of different needs. All products
harmonize with our tradition of good engineer-
ing and high quality.
HiQ® Specialty gas program.Equipment & gas distribution systems.
IntelliSwitch™. Automatic gas management system.The fully-automatic IntelliSwitch™ gas switchover represents the next generation of gas management systems. The IntelliSwitch™ offerscontinuous pressure and flow control from liquid cylinder or high pressure cylinder sources that enables the end-user to select the idealmode of supply by a simple push of a button. Proprietary software logic lowers yearly gas costs by eliminating liquid cylinder vent loss andexcess residual return which makes the IntelliSwitch™ the perfect gas management system. IS 641 has a maximum inlet pressure of 210 barwhilst the IS 641X version has a maximum of 310 bar. The IntelliSwitch™ can be delivered with a number of different inlet configurations.Please contact your local Linde representative for further information.
Technical data
IS 641/IS 641X
Max primary pressure 210/310 bar 3,000/4,500 psi
Outlet pressure 7 bar 100 psi
14 bar 200 psi
28 bar 400 psi
Features Fully automatic priority assign-
ment. Field adjustable software.
On-site source selection; Liquid
cylinder or high-pressure
service. Low loss technology.
RS 232 or 485 communication.
Connections NPT ½” female
Operating temperature –18 – +60°C 0 – +140°F
Weight 30.4 kg 67 lb
Material
Bodies Brass barstock
Housing Powder coated steel
Seals Viton®, Neoprene® and PTFE
Seating PCTFE or Viton®
The version with internal pilot (see table below) is the standard assembly.
It means that there is an internal pilot regulator that uses a very small
amount of the process gas from the right bank to operate the switching
mechanism. If ordered configured for external pilot, a supply of either air
or nitrogen at between 4.5 to 6 bar (65 to 85 psi) must be supplied to the
IntelliSwitch™. There is a 1/4" bulkhead tube fitting located at the bot-
tom of the cabinet when ordered as an external pilot.
The IntelliSwitch™ can be delivered with a NEMA 4 enclosure (addition
-N4 in the table below) designed for both indoor or outdoor use to pro-
vide a degree of protection of the internal apparatus against ingress of
solid foreign objects (falling dirt and windblown dust); and to provide a
degree of protection with respect to harmful effects on the equipment
due to the ingress of water (rain, sleet, snow, splashing water, and hose
directed water).
Product name bar psi HiQ® code
IS 641/Internal pilot 7 100 5936
IS 641/Internal pilot 14 200 5937
IS 641/Internal pilot 28 400 5938
IS 641/External pilot 7 100 5933
IS 641/External pilot 14 200 5934
IS 641/External pilot 28 400 5935
IS 641X/Internal pilot 7 100 5942
IS 641X/Internal pilot 14 200 5943
IS 641X/Internal pilot 28 400 5944
IS 641X/External pilot 7 100 5939
IS 641X/External pilot 14 200 5940
IS 641X/External pilot 28 400 5941
IS 641-N4/Internal pilot 7 100 5964
IS 641-N4/Internal pilot 14 200 5965
IS 641-N4/Internal pilot 28 400 5966
IS 641-N4/External pilot 7 100 5961
IS 641-N4/External pilot 14 200 5962
IS 641-N4/External pilot 28 400 5963
IS 641X-N4/Internal pilot 7 100 5970
IS 641X-N4/Internal pilot 14 200 5971
IS 641X-N4/Internal pilot 28 400 5972
IS 641X-N4/External pilot 7 100 5967
IS 641X-N4/External pilot 14 200 5968
IS 641X-N4/External pilot 28 400 5969
230 PS I16 BAR
DELIVERY PRESSUREADJUSTMENT
3000 PS IMAX .
G AS
R E S E T
G AS S O URC E
350 PS I24 BAR
C RYO G E NIC
500 PS I34 BAR
G AS S O URC E
BANK S E L E C T
16 BAR
230 PS I 350 PS I24 BAR
C RYO G E NIC G AS
3000 PS IMAX .
500 PS I34 BAR
R E ADY
DELIVERY
IN US ER E PL AC E
PS I BAR PWR
RIGHT BANKLEFT BANK
RE PL AC ER E ADY
R E MO T E
IN US E
314
365
79
159
81
81
approx.68 max
Inlet Inlet
Out
let
IN US ER E P L AC E
P WR R E MO T EP S I
IN US E
B AR
R E ADYR E ADY R E P L AC E
G AS
34 B AR
HIG H
C R Y O G E NIC
24 B AR
350 P S I 500 P S I
G ASS O UR C E
P R E S S UR E
S E L E C TB ANK
16 B AR
G AS
34 B AR
HIG HP R E S S UR E
230 P S I
C R Y O G E NIC
24 B AR
350 P S I16 B AR
230 P S I
G AS
R E S E T
500 P S I
S O UR C E
289
Front covershown open,broken away
406
508
Out
let
InletInlet
DELIVERY PRESSUREADJUSTMENT
DELIVERY
RIGHT BANKLEFT BANK
All measurements in millimeters.
IntelliSwitch™ IS 641 IntelliSwitch™ IS 641-N4
HiQ® Specialty gas program.Equipment & gas distribution systems.
STABLEFLOW™ HCS. Hydrogen control system.The STABLEFLOW™ hydrogen control system continuously monitors hydrogen pressure, purity and dewpoint in the generator casing on a real-time basis, controlling impure hydrogen venting and calling for pure hydrogen injection as required. The automated control of theSTABLEFLOW™ HCS replaces manual periodic hydrogen refill and its resulting variability from OEM specifications for hydrogen purity, pressureand dewpoint. Compliance with OEM specifications optimizes electric production efficiency and equipment life. By maintaining OEMspecifications for hydrogen pressure, purity, and dewpoint, the STABLEFLOW™ HCS reduces windage loss and optimizes electric generatingcapacity. Also, it reduces air emissions and extends equipment life.
Technical data
Purpose STABLEFLOW™ hydrogen control system (HCS)
precisely controls generator casing hydrogen
venting in response to real-time measure-
ments of purity and pressure. With HOGEN
HGS, this system automatically purges impure
hydrogen and replenishes purged gas with
high purity hydrogen, optimizing generator
performance.
Applicability STABLEFLOW™ hydrogen control system is
applicable to all hydrogen-cooled electric
generators.
Continuous measurement Dew point, hydrogen density, hydrogen pressure
Inlet H2 pressure 1.7–5.2 bar 25–75 psi
Operating temperature 5–50 °C 41–122 °F
Communications Ethernet – RJ45
H2 inlet/outlet connection ¼” compression fitting
Control cabinet purge gas Instrument air, ¼” compression fitting
Dimensions (W/D/H) 99/59/208 cm 39/23/82”
Weight 170 kg 375 lbs
Electrical specifications 200 – 240 VAC, 5 A single phase, 50/60 Hz
Dew point sensor
Dew point range -80 – +20 °C 0.5 ppmv min.
Accuracy +– 3 °C (or better) +– 0.015 ppmv
Repeatability +– 0.5 °C (or better) +– 0.002 ppmv
Response time < 10 sec. for 63% step change in moisture
content (wet-up or dry-down cycle)
H2 purity monitor
Measurement techn. Vibrating element
Response time < 10 sec.
Linearity +– 0.001 (+ 1% of set range)
Repeatability +– 0.001
Long term stability +– 0.003/month
Pressure transducer
Operating pressure 0–7 bar 0–100 psi
Operating temperature -30 – +50 °C -22 – +122 °F
Accuracy +– 0.25%, full scale
Linde Gas has introduced two advanced technology systems: the HOGEN®
hydrogen generation system (HGS), (further information on page 176)
and the STABLEFLOW™ hydrogen control system (HCS). Together, these
systems ensure automatic and continuous measurement and feedback
control of hydrogen purity and pressure for optimized generator perform-
ance.
Standard features• Fully automated
• Data logging
• Remote telemetry
• Local operator interface
• STABLEFLOW™ software control
• Integrated system controller
• Standard siting location is indors, floor mount with +– 3° of level.
Bottom-line benefitsHydrogen generation with the HOGEN® HGS and the STABLEFLOW™ HCS
can save substantial sums in most plants depending on their capacity. To-
gether, these systems increase the power generating capacity while min-
imizing windage loss. Moreover, they ensure longer generator component
life and drastically reduce handling costs.
OptionsLinde Gas offers a wide range of options to tailor HOGEN® HGS and
STABLEFLOW™ HCS to your specific operational requirements.
Please contact your local Linde Gas representative to discuss current op-
tions available to best fit your needs.
STABLEFLOW™ HCS, Hydrogen Control System.
Schematic setup of HOGEN® HGS and STABLEFLOW™ HCS at a power plant.
HiQ® Specialty gas program.Equipment & gas distribution systems.
C 490/1. Six-port single stage ultra high pressurecylinder regulator.The C 490/1 ultra high pressure piston sensed regulators are intended for primary pressure control of noncorrosive gases at a maximum inletpressure of 420 bar (6,000 psi). C 490/1 can be plain or equipped with a needle valve (type B).
The C 490/1 cylinder regulators are commonly used for airplane strut charging and aerospace hydraulic systems. Other areas of usage is chemical
& pharmaceutical manufacturing and research & development laboratories.
Technical data
Max primary pressure 420 bar 6,000 psi
Outlet pressure 0–50 bar 0–750 psi
0–105 bar 0–1,500 psi
0–170 bar 0–2,500 psi
0–240 bar 0–3,500 psi
0–310 bar 0–4,500 psi
0–420 bar 0–6,000 psi
Outlet gauge range 0–70 bar 0–1,000 psi
0–275 bar 0–4,000 psi
0–415 bar 0–6,000 psi
0–690 bar 0–10,000 psi
Connection Out = NPT ¼” female
Operating temperature –40 – +60°C –40 – +140°F
Weight 2.5 kg 5.6 lb
Material
Housing Brass, Cr plated
Stainless steel 316L
Seals Viton®
Membrane Stainless steel 316L
Seating Arlon®
Product name bar psi HiQ® code
C 490/1, brass 0–50 0–750 5604
C 490/1, brass 0–105 0–1,500 5605
C 490/1, brass 0–170 0–2,500 5606
C 490/1, brass 0–240 0–3,500 5607
C 490/1, brass 0–310 0–4,500 5608
C 490/1, brass 0–415 0–6,000 5609
C 490/1, stainless steel 0–50 0–750 5610
C 490/1, stainless steel 0–105 0–1,500 5611
C 490/1, stainless steel 0–170 0–2,500 5612
C 490/1, stainless steel 0–240 0–3,500 5613
C 490/1, stainless steel 0–310 0–4,500 5614
C 490/1, stainless steel 0–415 0–6,000 5615
C 490/1 B, brass 0–50 0–750 5616
C 490/1 B, brass 0–105 0–1,500 5617
C 490/1 B, brass 0–170 0–2,500 5618
C 490/1 B, brass 0–240 0–3,500 5619
C 490/1 B, brass 0–310 0–4,500 5620
C 490/1 B, brass 0–415 0–6,000 5621
C 490/1 B, stainless steel 0–50 0–750 5622
C 490/1 B, stainless steel 0–105 0–1,500 5623
C 490/1 B, stainless steel 0–170 0–2,500 5624
C 490/1 B, stainless steel 0–240 0–3,500 5625
C 490/1 B, stainless steel 0–310 0–4,500 5626
C 490/1 B, stainless steel 0–415 0–6,000 5627
All measurements in millimeters.
Drawings of other types available on request.
C 490/1 single stage regulator
18318
Ø53
Ø63
.5
C 490/1
HiQ® Specialty gas program.Equipment & gas distribution systems.
R 480/1. Single stage high flow regulator forcorrosive gases.The R 480/1 regulators are intended for primary pressure control of corrosive gases at high flow levels. The regulator has an internallyspringless and threadless design and positive shut-off seal, tied diaphragm design with positionable captured vent bonnet.
Other advantages are: Excellent leak integrity (created by metal to metal diaphragm to body seal) and smooth unobstructed flow path that
allows for complete purging. For other options than mentioned below please contact your local Linde representative.
Technical data
Max primary pressure 240 bar 3,500 psi
Outlet pressure 0–2 bar 0–30 psi
0–4 bar 0–60 psi
0–7 bar 0–100 psi
0–10 bar 0–150 psi
Inboard leak rate <10–9 atm cc/sec He
Connection Welded tube stubbs
Operating temperature –40 – +180°C –40 – +350°F
Weight 1.5 kg 3.2 lb
Material
Housing Stainless steel 316L/Hastelloy®
Seals Stainless steel 316L/Hastelloy®
Diaphragm Stainless steel 316L/Hastelloy®
Seating Vespel®
Product name bar psi HiQ® code
R 480/1, stainless steel 0–2 0–30 5945
R 480/1, stainless steel 0–4 0–60 5946
R 480/1, stainless steel 0–7 0–100 5947
R 480/1, stainless steel 0–10 0–150 5948
R 480/1, Hastelloy® 0–2 0–30 5949
R 480/1, Hastelloy® 0–4 0–60 5950
R 480/1, Hastelloy® 0–7 0–100 5951
R 480/1, Hastelloy® 0–10 0–150 5952
~14
0–
152
∅ 58
INLETOUTLET
∅ 60
∅ 69
19
0
10(.7)
20(1.4)
30(2.1)
40(2.8)
50(3.5)
60(4.2)
70(4.9)
80(5.6)
2(57)
4(113)
6(168)
8(226)
10(283)
12(340)
14(396)
16(453)
18(509)
20(566)
Flow rate – SCFM (LPM) N2
Inlet pressure = 100 PSIGFlow capacity Cv = 0.5
Out
let
pres
sure
–PS
IG(k
g/cm
2 )
R 480/1
All measurements in millimeters.
HiQ® Specialty gas program.Equipment & gas distribution systems.
C 421/1. Single stage low flow cylinder regulator.The C 421/1 low flow cylinder regulator is especially suitable for situations where a very high control accuracy is needed at low flows. It canbe used with gases and gas mixtures up to quality 6.0. For corrosive gases and gas mixtures with >1% corrosive components the P-model(equipped with purging device) is recommended.
Technical data
Max primary pressure 25 bar 3,300 psi
Outlet pressure 0.05–1.5 bar 0.7–22 psi
Outlet gauge range –1–3 bar –1.5–45 psi
Leak rate 10–8 mbar l/s He
Connection Out = ¼”-18 NPT female
Operating temperature –30 – +60°C –22 – +140°F
Weight 2.1 kg 4.6 lb
Material
Housing Stainless steel 316L
Seals PCTFE
Diaphragm Hastelloy® C276
Seating PCTFE
Product name bar psi HiQ® code
C 421/1 0.05–1.5 0.7–22 5953
C 421/1 P 0.05–1.5 0.7–22 5954
122
125
185~ 115 ~ 100
0 0.2 1 2 3 100.3 0.5 4 50
0.4
0.8
1.2
1.6
Flow, m3/h, airInlet pressure 4 bar
Out
let
pres
sure
,bar
C 421/1P
All measurements in millimeters.
Type P. Drawings of other types available on request.
HiQ® Specialty gas program.Equipment & gas distribution systems.
C 450/1 mini. Single stage mini cylinder regulator.The C 450/1 mini cylinder regulators are intended for primary pressure control of noncorrosive gases for qualities up to 6.0. For corrosivegases or gas mixtures use the stainless steel version. The regulator has a compensated main valve for significantly improved outlet pressureaccuracy similar to a dual-stage regulator.
Technical data
Max primary pressure 230 bar 3,300 psi
Outlet pressure 0–1.5 bar 0–22 psi
0–4 bar 0–60 psi
1–10 bar 1.5–145 psi
Outlet gauge range –1–2.5 bar –1.5–36 psi
–1–6 bar –1.5–90 psi
0–15 bar 0–220 psi
Leak rate 10–8 mbar l/s He
Connection Out = ⅛” NPT femaleOperating temperature –30 – +60°C –22 – +140°F
Weight 0.5 kg 1.1 lb
Material
Housing Brass, Cr plated
Stainless steel 316L
Seals PCTFE
Diaphragm Hastelloy® C276
Seating PCTFE (option PVDF)
Product name bar psi HiQ® code
C 450/1, brass 0–1.5 0–22 5955
C 450/1, brass 0–4 0–60 5956
C 450/1, brass 0–10 0–145 5957
C 450/1, stainless steel 0–1.5 0–22 5958
C 450/1, stainless steel 0–4 0–60 5959
C 450/1, stainless steel 0–10 0–145 5960
~ 110
35 60
42
~55
Inlet pressure = 20 bar Inlet pressure = 9 barFlow, m³/h, air
Out
letp
ress
ure,
bar
01
23
4
0 0.2 0.4 0.6 0.8 1 2 3 4 5
C 450/1 mini
All measurements in millimeters.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Safety solutions.
Some gases may be harmful, even if normalprecautions are employed. To handle thesegases it is necessary to use specialequipment.
In this chapter gas cabinets and specialty gas
purge panels are presented. Also Monitoring
systems (p. 218) and Containers can be viewed
as safety equipment. Containers are a good so-
lution when it is not possible to solve safety
problems in the existing premises. (see pages
164 – 169).
In addition to this, Linde can support you with
all kinds of scrubbers, gas detection systems
and personal alarms.
For full portfolio, please contact your local Linde
representative.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Safety solutions. Standard cabinets.Gas cabinets are used to store gas cylinders safely. A gas cabinet used for storing flammable or toxic gases should be equipped with forcedventilation. It is crucial that the cabinet is vented externally and not connected to the normal ventilation.
Technical data
Dimensions [mm] [inch]
Width (1 or 2 cylinders) 720 28.4
Width (3 cylinders) 1100 43.3
Depth 500 19.7
Height 2150 84.7
Features• Inspection window in armoured glass
• Lockable doors, openable 180°
• Two ventilation connections for optional flow direction
• Prepared for mounting of gas panels
• Adjustable racks
• Pre-bored holes for floor mounting
• Detachable hatch, prepared for tubing
• Painted sheet-iron or stainless steel
• Available for up to three cylinders
Product name HiQ® code
1 cylinder gas cabinet 3386
2 cylinder gas cabinet 3387
3 cylinder gas cabinet 3388
2000
50
375
500
25
75
∅ 160
1375
125
2150
Width
All measurements in millimeters.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Safety solutions. 2-valve purge gas panel.The Marathon range of manual and semi-automatic gas panels is the solution to your speciality gas source and distribution needs. Fromsimple manual self purge panels for inert gases through to purge-able systems for hazardous gases the Marathon range offers robust, costeffective basic systems that can be enhanced for safety, purity and operation by the addition of functional modules.
Technical data
High purity Ultra high purity
Leak rate
Inboard <1x10–9 sccs <1x10–9 sccs
Outboard <2 ppm He <2 ppm He
Particles per ft3
<10 counts 0.1 – 0.3 µm —
<5 counts 0.3 – 0.5 µm 0.1 – 0.3 µm
0 count >0.3 µm >0.3 µm
Moisture <20 ppb <20 ppb
Oxygen <20 ppb <10 ppb
Total hydrocarbons <10 ppb <10 ppb
316L SS electro-polished 15 µin Ra average 5–7 µin Ra average
Options, functional ESO – Emergency shut-off valve
HPA – High pressure access valve
BD SWG – Burst disc switch gauge
EFS – Excess flow switch
PLI – Process line isolation
DEL & CYL Switch gauge upgrade
Bellow valves
Change-over module
Options, purity CFG – Pre-filter
FF – Final filter metal
FF – Final filter Teflon®
Del. & Cyl. pressure transducers
Nanochem® purification
This gas panel is typically used to control non-reactive gases like nitro-
gen, etc. The gas panel works like a self-purging system, and removes
the air trapped in the gas panel, after cylinder change, by isolating the
regulator with the HPI valve, and flushing process gas via the HPV valve
to the atmosphere.
Typically used as a purge gas panel to ensure a safe and clean purge gas
source for sophisticated gas panels handling toxic, flammable or haz-
ardous gases.
Features• High pressure vent for purge
• High pressure isolation for purge
• Burst disk – failsafe protection for overpressure
• Cylinder and Delivery pressure measurement
• Tied diaphragm regulator
• Springless diaphragm valves
• Universal mounting plate
• VCR and orbital welded connections to process path
• Change-over module-ready
For ordering and further details, please contact your local Linde represen-
tative.
Tovent
Processgas out
Venturisupply
Tovent
VGS VGPLI
BDSWG
FF
BD
DEL
REG
CYL
HPI
HPV
CFG
ESO
HPAEFS
From gas source
Schematic. Options in blue.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Safety solutions. 3-valve process gas panel.The Marathon range of manual and semi-automatic gas panels is the solution to your speciality gas source and distribution needs. Fromsimple manual self purge panels for inert gases through to purge-able systems for hazardous gases the Marathon range offers robust, costeffective basic systems that can be enhanced for safety, purity and operation by the addition of functional modules.
Self-purging gas panel with a low pressure isolation valve added to allow
isolation of the panel from the process line. This panel is used as a
process gas panel for non hazardous gases where demands are high but
not extreme.
Features• High pressure vent for purge
• High pressure isolation for purge
• Purge gas inlet
• Burst disk – failsafe protection for overpressure
• Cylinder and Delivery pressure measurement
• Tied diaphragm regulator
• Springless diaphragm or bellow valves
• Universal mounting plate
• VCR and orbital welded connections to process path
• Change-over module-ready
For ordering and further details, please contact your local Linde represen-
tative.
Technical data
High purity Ultra high purity
Leak rate
Inboard <1x10–9 sccs <1x10–9 sccs
Outboard <2 ppm He <2 ppm He
Particles per ft3
<10 counts 0.1 – 0.3 µm —
<5 counts 0.3 – 0.5 µm 0.1 – 0.3 µm
0 count >0.3 µm >0.3 µm
Moisture <20 ppb <20 ppb
Oxygen <20 ppb <10 ppb
Total hydrocarbons <10 ppb <10 ppb
316L SS electro-polished 15 µin Ra average 5–7 µin Ra average
Options, functional ESO – Emergency shut-off valve
HPA – High pressure access valve
BD SWG – Burst disc switch gauge
EFS – Excess flow switch
PLI – Process line isolation
DEL & CYL Switch gauge upgrade
Bellow valves
Change-over module
Options, purity CFG – Pre-filter
FF – Final filter metal
FF – Final filter Teflon®
Del. & Cyl. pressure transducers
Nanochem® purification
Tovent
Tovent
Processgas out
Venturisupply
HPV
CFG
ESO
HPAEFS
From gas source
Purge gassupply in
VGS VGPLI
PGI
BDSWG
FF
BD
DEL CYL
HPI
REG
Schematic. Options in blue.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Safety solutions. 5-valve process gas panel.The Marathon range of manual and semi-automatic gas panels is the solution to your speciality gas source and distribution needs. Fromsimple manual self purge panels for inert gases through to purge-able systems for hazardous gases the Marathon range offers robust, costeffective basic systems that can be enhanced for safety, purity and operation by the addition of functional modules.
This panel includes low pressure vent line, allowing vacuum assisted reg-
ulator purge and process line purge which improves system start up pro-
cedure. Pneumatic emergency shut-off valve and vacuum generator are
standard.
Suitable for gases like SiH4, AsH3, HCl, PH3.
Features• High pressure vent for purge
• Low pressure vent for purge
• High pressure isolation for purge
• Purge gas inlet
• Burst disk – failsafe protection for overpressure
• Cylinder and delivery pressure measurement
• Tied diaphragm regulator
• Springless diaphragm or bellow valves
• Modular design
• VCR and orbital welded connections to process path
• Change-over module-ready
For ordering and further details, please contact your local Linde represen-
tative.
Technical data
High purity Ultra high purity
Leak rate
Inboard <1x10–9 sccs <1x10–9 sccs
Outboard <2 ppm He <2 ppm He
Particles per ft3
<10 counts 0.1 – 0.3 µm —
<5 counts 0.3 – 0.5 µm 0.1 – 0.3 µm
0 count >0.3 µm >0.3 µm
Moisture <20 ppb <20 ppb
Oxygen <20 ppb <10 ppb
Total hydrocarbons <10 ppb <10 ppb
316L SS electro-polished 15 µin Ra average 5–7 µin Ra average
Options, functional ESO – Emergency shut-off valve
HPA – High pressure access valve
BD SWG – Burst disc switch gauge
EFS – Excess flow switch
PLI – Process line isolation
DEL & CYL Switch gauge upgrade
Bellow valves
Change-over module
Options, purity CFG – Pre-filter
FF – Final filter metal
FF – Final filter Teflon®
Del. & Cyl. pressure transducers
Nanochem® purification
From gas source
Purge gassupply in
Processgas out
Tovent
Tovent
Venturisupply
REG
BDSWG
HPV
CFG
ESO
HPA
PGI
DELCYL
HPI
BD
PLI
LPV
LPI
FF
EFS
VGS VG
Schematic. Options in blue.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Safety solutions. Operation monitor.Marathon operation monitors provide operational and safety enhancements for manual and semi-automatic gas panels. Speciality gasequipment operates largely unattended and unsupervised by personnel – the operation monitor provides safe, cost effective supervision andfailsafe shutdown if a hazardous condition is detected. The operation monitor provides at-a-glance status information and signals conditionsthat require operator attention (low cylinder pressure for example) Interfaces to remote monitoring and FMCS systems provide basic statusand detailed operation parameters respectively. The operation monitor is available in two models. OM1 is suitable for single cylinder panelsand interfaces to the full range of Marathon safety sensors. OM2 provides all of the safety and operational features of OM1 but is for doublegas panels with auto-change-over.
Technical data
Dimensions, W/H/D OM1 300/220/123
OM2 600/220/123
Supply voltage 100 – 250 VAC
Supply current 5 A
Internal & external logic 24 VDC
Pressure transducers 4 – 20 mA
Cylinder scales 4 – 20 mA
Pneumatic supply (CDA*) 6 bar 80 psi
Options Control of ACV
Auto-changeover
Transducer pressure display
Cylinder scale weight display
Wall mount bracket
Cylinder cabinet mounting
Pendant operator interface
Modbus interface to FMCS
Marathon operation monitors can optionally be interfaced and configured
to a full range of gas panel and peripheral sensors. In this way the level
of safety and operation functions can be selected to suit the gas, environ-
ment and operational preferences. The monitors can also be delivered
with a modbus FMCS link for remote monitoring. Please order a Marathon
Operation Monitors data sheet from your local Linde representative for
more details.
Features• PLC based
• Failsafe shutdown logic
• At-a-glance status indicators
• Audible alarms
• LCD operator interface
• Password access levels
• Intuitive menu-driven operation
• Cylinder cabinet or wall mounted
• Digital and analogue sensor interfaces
• Remote status interface
• Meets all relevant SEMI standards, all relevant European directives (CE)
and all relevant National standards in countries of sale
• Manufactured under ISO9000:2001 and ISO14001 environments
* compressed dry air
Marathon operation monitor OM1
Marathon operation monitor OM2
HiQ® Specialty gas program.Equipment & gas distribution systems.
Safety solutions. Fully automatic.The Olympian range of fully automatic systems has, at its heart, a PLC based control system which monitors a wide range of safety featuresand hazard conditions and provide failsafe shutdown in the event of a serious problem. Manifold conditions are constantly monitored and thefully automatic purge sequences include critical condition testing for failsafe operation. Password security levels ensure that key features areadequately protected and alarm conditions and purge sequences are comprehensively parameterised to enable safety and efficiency to betuned to customer specifics. The color touch screen has a full menu of active graphics providing easy to read information on all operationparameters – including alarm history and trend graphs.
Our gas cabinets represent the next generation of ultra-pure source gas
panels, with a state of the art controller system, offering unique in-line
architecture and a purge block valve designed to minimize dead space
and overall internal volume. These features guarantee the optimum purge
effect and a thorough decontamination of the source gas system.
Features and benefits• Designed specifically for the requirements of submicron device manu-
facturing.
• Intuitive design helps reduce operator errors and improves safety.
• Purge block valve design allows very short purge time due to small in-
ternal volume of 1.3 cm3.
• Contaminated purge gas is discharged without entering flowing down-
stream of the purge block valve.
• In-line flow path virtually eliminates dead space.
• Modular, welded design improves reliability and reduces spare parts
stocking requirements.
• Integrated automatic source switchover capability for critical redun-
dancy and guaranteed uptime.
• Front removable components for improved servicing.
• Vacuum Venturi assisted purge for a quick and efficient manifold.
• Assembled in a clean room environment according to strict industry
standards and specifications.
• Meet all relevant SEMI standards, European Safety Directives and are
fully CE compliant.
For ordering and further details, please contact your local Linde represen-
tative.
Technical data
Inboard leak rate <10–9 scc/sec He
Particle test
≥0.1 µm size 0.18 ptc/l 5 ptc/ft3
>0.3 µm size 0 ptc/l 0 ptc/ft3
Moisture test <10 ppb
Oxygen test <10 ppb
Material 316 L stainless steel (secondary remelt)
Surface finish ≤ 0.18 Ra µm ave. ≤ 7 Ra µin ave.
Dimensions [mm] [inch]
Width (1 or 2 cylinders) 800 31.5
Width (3 cylinders) 1,200 47.2
Depth 550 21.7
Height 2,300 90.6
Certification: compliant
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Containers.Ready-to-use gas supply systems.
A good and safe way to store gas cylindersare to use a gas container. Linde has a rangeof containers especially suited for thispurpose which fulfill all relevant regulationsand can be equipped with a range of“extras”, such as dividers, heating, forcedventilation and gas detectors.
A gas container should always be considered
when dealing with flammable or otherwise
harmful gases and is a cost-effective way of
complying with fire regulations.
Integrated cabinet
for gas outlet connections.
Fire-resistant bushing.
Fire-resistant bushing.
Gas detector (optional).
Roller conveyor
(optional).
Hollow sections
for fork lift.
Heating coil in the
floor (optional).Integrated cabinet
for electrical connections.
Explosion proof globe light.
Air vent.
Fire insulation.
Semi-automatic gas panel (selected
from the equipment program).
External lighting
with twilight relay.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Containers. Ready-to-use gas supply systems.
Technical data
Container model 10 foot 20 foot
Measurements
Length [m] (ext/int) 2.99/2.26 6.06/5.33
Width [m] (ext/int) 2.43/2.16 2.43/2.16
Height [m] (ext/int) 2.59/2.28 2.59/2.28
Electrical distribution box 16 A with two 10 A sockets.
Equipped with earth-fault and
circuit breakers.
Lighting externally Twilight relay and separate
on/off switch.
Explosion proof Class EEx e 11. Ignition T3–T1
globe light internally
Fire insulation
– on the rear wall
and side walls Class A60
– on the remainder Class B15
Fire bushings Type Lykab
Paint system Complies with environmental
Hempel class 3
Heating coil in Output ~ 9 W/m
the floor* Capacity: at –10 °C outdoor
temperature the system main-
tains an indoor temperature of
about +18 °C.
Fan for forced Type Ex-140-4C. Output 100 W.
ventilation* Capacity free-blowing 532 m3/h.
The delivery of gas cylinders and cylinder bundles/banks directly tothe gas storage provides a safe and convenient solution to gascylinder handling. At the same time safety is increased as the gascylinders do not need to be transported and stored in the productionpremises.
Using the Ready-To-Use gas supply system you get a continuous supply
of gas to each individual workstation, which means less downtime and
fewer unplanned interruptions as well as lower overall costs.
Fewer and larger gas cylinders that serve more users means more effec-
tive utilization of the gas in the cylinders, which results in lower costs for
the gas, cylinder rent and transportation.
Delivery and purchasing routines can be centralized and made more effi-
cient as the overall gas consumption and cylinder handling is much easier
to monitor.
A service agreement guarantees trouble–free gas supply without un-
planned production interruptions.
Together with the customer we carry out a requirement analysis regard-
ing the gas quality and operating conditions. After this, the appropriate
equipment will be installed in the selected container. If, for example, a
continuous gas supply without interruptions is required, then a semi–au-
tomatic gas panel that automatically switches from an empty to a full
cylinder is chosen. If gases with different physical properties are to be
stored in the same container, the container is divided using partitions so
that gases can be separated.
The container is fully equipped by Linde, to include all electrical connec-
tions and piping. This means that the system can be put into operation
immediately after delivery.
All models have a three layer rust protection finish using environmentally
suited water based epoxy and acrylic paint. Water drainage from the roof
and drip mouldings above the doors are standard on all models.
Linde’s ready-to-use containers are available in three standard sizes de-
signed according to a common basic philosophy.
Continues...
* Optional
The containers are manufactured according to ISO 668,
ISO 1496-1, ISO 1161 standards.
20 foot container with roller conveyor.
Loading of cylinder bundle.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Containers. Ready-to-use gas supply systems....continued
Name HiQ® code10 foot container 3397
20 foot container 3398
Custom made container 3399
Safety– Double doors with cylinder locks.
– Air vents.
– Fire insulation on the rear wall and side walls class A60, remainder
class B15.
– Fire resistant bushings for pipe and cable inlets on the side walls and
any partitions.
– Separate integrated cabinets for electrical equipment and gas
connections in optional side wall.
– Electrical distribution box 16 A with two 10 A sockets. Equipped with
earth–fault and circuit breakers.
– Internal Explosion Proof globe light.
– External lighting with twilight relay and separate on/off switch.
Handling– The containers are equipped with hollow sections for lifting with a
fork lift truck, which makes moving easy if requirements change.
– Folding ramps by the doors to simplify transportation of gas cylinders.
– The need to transport gas cylinders in production premises is eliminated.
– Handling of heavy gas cylinders is minimized.
Economy– Supplied ready for connection to a gas distribution system.
– Minimizes investment requirements.
– Buy or lease option.
– Complete overview of gas consumption and the size of the cylinder
stock.
Options– Gas panels and other components are installed to meet your
requirements.
– Floor heating thermostat controlled.
– Roller conveyors for handling of cylinder bundles/ banks (does not
apply to CM container).
– Gas detectors for inflammable and corrosive gases.
– Air conditioning unit.
– Fan for forced ventilation (exhaust ventilation).
– Sprinkler.
– Partition with fire–resistant bushings (a maximum of 2 walls in a 20
foot container).
– Extra passage door.
Custom made container.
Explosion proof globe light. Gas detector (optional).
Integrated cabinet for gas outlet connections. Integrated electrical connections cabinet.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.
In some cases the use of cylinder gas mightbe unsuitable. This might be for safetyreasons or if it is difficult to transport thecylinders. Linde has a range of small andreliable gas generators to handle thesesituations.
These gas generators produces gas on site for
instant use. The main advantage with gas gen-
erators is that since the gas is produced on site,
shutting of the power stops the gas production,
which could be essential at power failure if the
gas produced is hydrogen. Another advantage
is that there are no need to store large amounts
of compressed gas since there is instant access
to newly produced gas. Gas generators are
small and creates a flexibility in the set up of
the laboratory, and simplifies rearrangements of
the lab. Due to their small size, laboratory space
can be saved. To ensure continuous supply, a
cylinder or a second generator has to be con-
nected to the system as backup.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.The hydrogen no-maintenance series.Hydrogen is used in chromatography both as a carrier gas and as a fuel for instance for flame ionization detectors (FID) or flame photometricdetectors (FPD). It is either delivered in classical gas cylinders or produced on site. On-site production ensures a continuous supply andallows for small total hydrogen volumes in the lab (<40 ml contained volume/unit). There are three models of the HiQ® no-maintenancegenerator. Apart from the basic model there is one with remote control (NMH2 XXX-RC) and one with cascading flow (NMH2 XXX-CF) allowingfrom two to a maximum of 32 units to be connected in parallel.
Technical data
Max H2 flow rate 0.10 – 1.0 l/min
Delivery pressure 0.1–10.5 bar 1–155 psi
H2 purity >99.9999% (>6.0)
Electrolysis cell Solid polymer membrane
Safety Auto shut-off and low internal
volume (< 40ml)
Auto-drying system No maintenance of drying
cartridges (exclusive system)
Water Deionized or distilled
User interface Set points, system status,
user parameter
Display LCD display 128 x 64 pixels,
set points, status, alarms
Options
I/O board containing:
• RS232C bi-directional/2 ports RS485
• Cascading up to 32 units
• Potential free relay contacts
Software for PC-control capability (requires I/O board)
Dimensions (W/D/H) 23/35/43 cm
8⅝”/13⅜”/15¾”
Weights
NMH2 100 – 300 17 kg 37.5 lbs
NMH2 500 – 1L 18 kg 40 lbs
The HiQ® hydrogen generator is a no-maintenance device with innovative
membrane-technology. Its advanced dual-column drying system automat-
ically removes residual moisture from the hydrogen produced. The col-
umn materials are also regenerated automatically, and in the final
purification not even a desiccant cartridge is needed. For the electrolytic
dissociation process, the HiQ® hydrogen generator requires no caustic
chemical solutions. Instead, it uses harmless deionized water to produce
a reliable, continuous output of 6.0 hydrogen (>99.9999% pure). System
operating status and diagnostic data appear on a user-friendly digital dis-
play. In case of an internal error, the unit is put on standby by an auto-
shut-off procedure. Selectable, multiple alarms alert to unwanted shifts in
operating conditions such as low water level, poor water quality, low
pressure (leak) and power supply conditions.
Hydrogen flow and water quality are monitored by continuous LCD indica-
tion. The gas delivery pressure is indicated by LCD and can be adjusted
manually via a membrane control pad. A cable interface permits remote
computer monitoring of all functions.
Model Description HiQ® codeNMH2 100 100ml/min 5500
NMH2 160 160ml/min 5501
NMH2 250 250ml/min 5502
NMH2 300 300ml/min 5995
NMH2 500 500ml/min 5503
NMH2 600 600ml/min 5996
NMH2 1L 1,000ml/min 5989
NMH2 100-RC 100ml/min 5504
NMH2 160-RC 160ml/min 5505
NMH2 250-RC 250ml/min 5506
NMH2 300-RC 300ml/min 5997
NMH2 500-RC 500ml/min 5507
NMH2 600-RC 600ml/min 5998
NMH2 1L-RC 1,000ml/min 5990
NMH2 250-CF 250ml/min 5508
NMH2 300-CF 300ml/min 5999
NMH2 500-CF 500ml/min 5509
NMH2 600-CF 600ml/min 6000
NMH2 1L-CF 1,000ml/min 5991
Optional featuresNMH2-PCI-CC With PC interface and control cable 5510
NMH2-EXT-RC With handheld external remote control unit 5511
NMH2-H2O-RF With automatic water refilling option 5512
Certification: compliant
Consumables/spare partsNMH2-DI-Bag Deionizer bag, replacement 5513
NMH2-RCC-10 Remote control cable (15-conductors) 10m 5514
NMH2-RCC-10 Remote control cable (15-conductors) 25m 5515
NMH2-RCC-10 Remote control cable (15-conductors) 50m 5516
HiQ® hydrogen no-maintenance generator.
HiQ® hydrogen no-maintenance generator in principal.
Water drain port
Checkvalve
Waterreservoir
Over-pressurerelief port
Auto dryerNM system
Solid Polymer Electrolyte (SPE) cell
Pressuregauge
Pressuretransducer
Shut-off valve
Drying tube
H2
H2 outlet
O2
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.The hydrogen pure gas series.Pure gaseous hydrogen is needed in gas analyzers, plasma chambers, isolated environments, or as a fuel gas for flame tools. It is eitherdelivered in classical gas cylinders or produced on site. On-site production ensures a continuous supply, keeping the total hydrogen volumein the lab as low as possible. There are three models of the HiQ® pure gas generator. Apart from the basic model there is one with remotecontrol (PGH2 XXX-RC) and one with cascading flow (PGH2 XXX-CF) allowing from two to a maximum of 32 units to be connected in parallel.
Technical data
Max H2 flow rate 0.10 – 0.60 l/min
Delivery pressure 0.1–7 bar 1–100 psi
H2 purity 99.999% (5.0)
Electrolysis cell Solid polymer membrane
Safety Auto shut-off
Water Deionized
User interface Set points, system status,
user parameter
Display LCD display with set points,
status, alarms
Options
I/O board containing:
• RS232C bi-directional/2 ports RS485
• Cascading up to 32 units
• Potential free relay contacts
Software for PC-control capability (requires I/O board)
Dimensions (W/D/H) 22/33/39.5 cm
8⅔”/13”/15⁵⁄₉”Weights
PGH2 100 – 300 16.5 kg 36 lbs
PGH2 500/600 18 kg 40 lbs
The HiQ® hydrogen generator relies on the newest electrolytic membrane
technology, which is significantly cleaner than conventional hydrogen
generation. This new technology reduces maintenance and cleaning to a
minimum. It permits a chemical-free, trouble-free and long-term produc-
tion of hydrogen – simply from the electrolysis of deionized water. No
free acids or alkalines are used, thus avoiding caustic impurities that
might affect hydrogen quality and degrade the system.
Features:• LCD-based display and membrane control pad for simple operation
• Multiple alarms (low water level, poor water quality, low pressure, in-
sufficient power supply)
• Requires deionized water instead of caustic electrolytic solutions
• Replaceable desiccant cartridge provides final purification step to re-
move moisture
• Cascading flow control allows multiple units to be connected for larger
capacity flows (option)
• Cable interface permits remote computer monitoring of all functions
(option)
Model Description HiQ® codePGH2 100 100ml/min 5517
PGH2 160 160ml/min 5518
PGH2 250 250ml/min 5519
PGH2 300 300ml/min 6001
PGH2 500 500ml/min 5520
PGH2 600 600ml/min 6002
PGH2 100-RC 100ml/min 5521
PGH2 160-RC 160ml/min 5522
PGH2 250-RC 250ml/min 5523
PGH2 300-RC 300ml/min 6003
PGH2 500-RC 500ml/min 5524
PGH2 600-RC 600ml/min 6004
PGH2 250-CF 250ml/min 5525
PGH2 300-CF 300ml/min 6005
PGH2 500-CF 500ml/min 5526
PGH2 600-CF 600ml/min 6006
Optional featuresPGH2-PCI-CC With PC interface and control cable 5527
PGH2-EXT-RC With handheld external remote control unit 5528
PGH2-H2O-RF With automatic water refilling option 5529
Certification: compliant
Consumables/spare partsPGH2-DI-Bag Deionizer bag, replacement 5530
PGH2-DES-Cart Desicant cartridge with fittings, replacement 5531
PGH2-RCC-10 Remote control cable (15-conductors) 10m 5532
PGH2-RCC-10 Remote control cable (15-conductors) 25m 5533
PGH2-RCC-10 Remote control cable (15-conductors) 50m 5534
HiQ® hydrogen pure gas generator.
HiQ® hydrogen pure gas generator in principal.
Water drain port
Checkvalve
Waterreservoir
Over-pressurerelief port
Dryingcartridge
Solid Polymer Electrolyte (SPE) cell
Pressuregauge
Pressuretransducer
Shut-off valve
Drying tube
H2
H2 outlet
O2
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.HOGEN® HGS hydrogen generation system.In today’s challenging business environment, power plant operators must strive for the most efficient operations across multiple aspects ofperformance. In particular they have to take into account: the fuel expense and generation capacity, safety and security, hydrogen avail-ability, emissions reduction, and personnel productivity. Many power plants today are not running optimized. They operate out of OEMspecifications for hydrogen purity, pressure and dewpoint, costing hundreds of thousands of dollars every year in excess fuel costs, lostgeneration revenue, emissions credits, and decreased winding life.
Technical data
Net H2 production rate Nm3/h SCF/h SLPM kg/24h
0°C, 1 bar 70°F, 1 atm 70°F, 1 atm –
HGS S20 0.53 20 9.4 1.14
HGS S40 1.05 40 18.8 2.27
HGS H2m 2.0 76 35.8 4.31
HGS H4m 4.0 152 71.7 8.63
HGS H6m 6.0 228 107.6 12.94
Delivery pressure
HGS S 13.8 bar 200 psi
HGS H 15.0 bar 218 psi
H2 purity 99.9995% (5.5)
Water requirement (deionized)
Pressure 1.5 – 4 bar 21.8 – 58 psi
Consumption rate
HGS S20 0.47 l/h 0.13 gal/h
HGS S40 0.94 l/h 0.25 gal/h
HGS H2m 1.83 l/h 0.50 gal/h
HGS H4m 3.66 l/h 0.96 gal/h
HGS H6m 5.50 l/h 1.42 gal/h
Dimensions (W/D/H)
HGS S 97/79/106 cm 38”/31”/42”
HGS H 180/81/198 cm 71”/32”/78”
Weight
HGS S20 215 kg 475 lbs
HGS S40 215 kg 475 lbs
HGS H2m 700 kg 1500 lbs
HGS H4m 747 kg 1600 lbs
HGS H6m 794 kg 1700 lbs
Electrical specifications
HGS S 205 – 240 VAC, single phase, 50 or 60 Hz
HGS H 380 – 480 VAC, 3 phase, 50 or 60 Hz
Cooling
HGS S Air-cooled
HGS H Liquid-cooled
Linde Gas has introduced two advanced technology systems: the HOGEN®
hydrogen generation system (HGS) and the STABLEFLOW™ hydrogen con-
trol system (HCS), further information on page 140. Together, these sys-
tems ensure automatic and continuous measurement and feedback
control of hydrogen purity and pressure for optimized generator perform-
ance.
The HOGEN® HGS is a proton exchange membrane (PEM) water electroly-
sis system that uses electricity to separate water into hydrogen and oxy-
gen. The hydrogen is produced at 13.8bar/200psi pressure without a
compressor and at a purity of 99.9995% continuously and without opera-
tor intervention.
The compact HOGEN® HGS can be placed on the power plant generator
deck or any other indoor non-classified plant area. Due to its unique de-
sign, the HOGEN® HGS contains virtually no hydrogen, even when gener-
ating hydrogen at up to 6Nm3/228 SCF per hour – enough hydrogen to
cool power plants as large as 1,500MW.
The HOGEN® HGS provides reliable, safe, low-cost hydrogen for generator
blanketing and increases safety and security by eliminating hydrogen
storage, cylinder handling and routine hydrogen delivery.
Standard features• Fully automated, push-button start/stop
• Automatic fault detection and system depressurization
• On-board H2 detection
• Emergency stop
Standard siting requirementsIndoor, level ± 1°, 0 to 90% relative humidity non-condensing, non-haz-
ardous/non-classified environment. Proper ventilation must be provided
from a non-hazardous area.
OptionsLinde Gas offers a wide range of options to tailor your HOGEN® HGS to
your specific operational requirements. Please contact your local Linde
Gas representative to discuss current options available to best fit your
needs.
ReferencesHOGEN® hydrogen generation systems are in place worldwide at power
plants from 35 MW to 3,600 MW capacity.
Please contact us for a current reference list.
Certification: compliant
HOGEN® HGS hydrogen generators (HOGEN® HGS H to the left and HGS S to the right).
Schematic setup of HOGEN® HGS and STABLEFLOW™ HCS at a power plant.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.Nitrogen SIROCCO DS-PSA series.The SIROCCO high purity nitrogen gas generators works with DS-PSA technique. Including integral oil-free air compressors as standard, thegenerators deliver a continuous stream of 99.999%+ pure nitrogen gas with a minimal residual oxygen content without the need forsecondary purification. Version 3A includes a separate and independent compressed instrument air system. The SIROCCO series of nitrogengas generators is ideal for operation as nitrogen gas supply for all kind of laboratory and chromatography applications.
Technical data
Max. N2 flow rate (at 20°C, 1 bar)
DS-PSA-3 3 l/min
DS-PSA-5 5 l/min
Delivery pressure, +-0.5% 5 bar 73 psi
N2 purity ≥99.999%
Oxygen content <10 ppm
Index of protection IP2x (acc. IEC 60529, rev 2.1)
Temperature range 10–40 °C 50–104 °F
Noise level <60 dB(A)
Display Microprocessor controlled
graphic display, 128 x 64 pixels
Power 230V/50Hz 110V/60Hz
Power consumption 820W
Dimensions (W/D/H) 48/83.5/64 cm 19/33/25.2”
Weight 110 kg 242.5 lbs
SIROCCO DS-PSA nitrogen gas generators use a patented DUAL STEP pres-
sure swing adsorption (DS-PSA) system. Pressure swing adsorption is well
known and the DUAL STEP system is a new innovation which is a much
more economical and much more efficient technique compared with the
traditional standard PSA technique. The DS-PSA system remove oxygen,
carbon dioxide and water from compressed air. The resulting stream of
high purity nitrogen gas (99.999%) is ideal for laboratory applications in-
cluding GC carrier gas, make-up gas, and many other applications like ICP
etc. Version DS-PSA-N2-3A also produces a 3 l/min flow at a pressure of 5
bar (73 psi) of clean air for other use. The compressed air system includes
a filtration and drying system and is completely separated from the N2
part of the generator.
All SIROCCO DS-PSA gas generators are designed and manufactured
within a rigorous ISO9001 quality system.
Advantages:
• Nitrogen produced at low pressure and ambient temperature removes
the need for high pressure cylinders or liquid dewars
• A constant, uninterrupted gas supply of guaranteed purity eliminates
interruptions of analyses to change cylinders and reduces the amount
of instrument re-calibrations required
• Up to 99.999%+ pure nitrogen gas produced as standard. No need for
costly downstream secondary filtration
• Integral oil-free air compressor guarantees continuous gas supply, in-
dependent of inhouse compressed air supply
• The gas generators can easily be installed in the laboratory
Model Description HiQ® code
DS-PSA-N2-3 SIROCCO DS-PSA, 3 l/min, 230V 5979
DS-PSA-N2-3A SIROCCO DS-PSA, 3 l/min, air, 230V 5980
DS-PSA-N2-5 SIROCCO DS-PSA, 5 l/min, 230V 5981
DS-PSA-N2-3/110 SIROCCO DS-PSA, 3 l/min, 110V 5982
DS-PSA-N2-3A/110 SIROCCO DS-PSA, 3 l/min, air, 110V 5983
DS-PSA-N2-5/110 SIROCCO DS-PSA, 5 l/min, 110V 5984
MaintenanceDS-PSA-AK Maintenance kit 5985
DS-PSA-4000K 4000 hours maintenance kit 5986
Certification: compliant
HiQ® SIROCCO DS-PSA nitrogen generator.
HiQ® SIROCCO DS-PSA nitrogen generator in principal.
Cooling coils
Separate air feed, version 3A only
Compressedair filter
Checkvalve
Checkvalve
Instrument air outlet
CMS 1 tube
Air inletcompressors
N2 98% outlet
N2 99.999% outlet
CMS 2 tube
Recycle nitrogen
Vacuum pump
Residual O2 in airPurge air
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.BORA nitrogen mini series.The BORA mini nitrogen gas generators includes an integral oil-free air compressor as standard. The generators deliver a continuous streamof pure nitrogen gas with a low residual oxygen content without the need for secondary purification. The BORA series of mini nitrogen gasgenerators is ideal for operation as nitrogen gas supply for all kind of laboratory and chromatography applications.
Technical data
Max. N2 flow rate (at 20°C, 1 bar)
B-PSA-500 500 ml/min
B-PSA-750 750 ml/min
B-PSA-1300 1300 ml/min
Delivery pressure 4 bar 58 psi
N2 purity
B-PSA-500/750 ≥99.999%
B-PSA-1300 ≥99.995%
Oxygen content
B-PSA-500/750 <10 ppm
B-PSA-1300 <50 ppm
Temperature range 10–40 °C 50–104 °F
Noise level <50 dB(A)
Power 230V/50Hz 110V/60Hz
Dimensions (W/D/H) 35/40/30 cm 13.8/15.7/11.8”
Weight 18 kg 40 lbs
The BORA mini nitrogen gas generators use the pressure swing adsorp-
tion (PSA) system, as used in thousands of systems worldwide to remove
oxygen, carbon dioxide and water from compressed air. The resulting
stream of high purity nitrogen gas is ideal for applications including GC
carrier, make-up gas, generally for all low flow applications. The BORA se-
ries of nitrogen gas generators is incredibly miniaturized and very silent,
ideal to be placed in a little space like under or on a bench. The BORA se-
ries is the smallest sized high purity nitrogen generator worldwide.
All BORA gas generators are designed and manufactured within a rigor-
ous ISO9001 quality system.
Advantages:
• Nitrogen produced at low pressure and ambient temperature removes
the need for high pressure cylinders or liquid dewars
• A constant, uninterrupted gas supply of guaranteed purity eliminates
interruptions of analyses to change cylinders and reduces the amount
of instrument re-calibrations required
• 99.999%+ (99.995%+ for model B-PSA-1300) pure nitrogen gas pro-
duced as standard. No need for costly downstream secondary filtration
• Integral oil-free air compressor guarantees continuous gas supply, in-
dependent of inhouse compressed air supply
• The gas generators can easily be installed in the laboratory
Model Description HiQ® code
B-PSA-500 BORA PSA mini, 500 ml/min, 230V 5928
B-PSA-750 BORA PSA mini, 750 ml/min, 230V 5973
B-PSA-1300 BORA PSA mini, 1300 ml/min, 230V 5929
B-PSA-500/110 BORA PSA mini, 500 ml/min, 110V 5974
B-PSA-750/110 BORA PSA mini, 750 ml/min, 110V 5975
B-PSA-1300/110 BORA PSA mini, 1300 ml/min, 110V 5976
MaintenanceB-PSA-AK-500 Maintenance kit/500 ml/min 5930
B-PSA-AK-750/1300 Maintenance kit/750/1300 ml/min 5977
B-PSA-4K-500 4000 h filters kit/500 ml/min 5931
B-PSA-4K-750/1300 4000 h filters kit/750/1300 ml/min 5978
B-PSA-24K-500 24000 h maintenance kit/500 ml/min 5932
B-PSA-24K-750/1300 24000 h maintenance kit/750/1300 ml/min 5994
B-PSA-24TK-500 24000 h tubing kit/500 ml/min 5993
B-PSA-24TK-750/1300 24000 h tubing kit/750/1300 ml/min 5992
Certification: compliant
HiQ® BORA nitrogen mini generator.
HiQ® BORA nitrogen mini generator in principal.
Coolingcoil
Compressedair filter
Check valves
Purge line
CMStubes
Air inletcompressor
PLC
N2 outlet
Nitrogenreservoir
Inletsolenoid
valves
Exhaust solenoid valves N2 pressure pumpand flow control
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.ELSD nitrogen generator without compressor.The ELSD mini nitrogen gas generator deliver a continuous stream of pure nitrogen gas with a low residual oxygen content without the needfor secondary purification. The ELSD mini nitrogen gas generator is ideal as source for inert gas and purge gas including ELSD systems.
Technical data
Max. N2 flow rate
at 20°C, 1 bar 4 l/min (up to)
Delivery pressure 5 bar 73 psi
N2 purity >98%
Compressed air feed specifications
Pressure 7 bar 100 psi
Purity ISO 8573.1, Class 1.2.1
Temperature range 10–40 °C 50–104 °F
Noise level <48 dB(A)
Power 230V/50Hz 110V/60Hz
Dimensions (W/D/H) 35/40/30 cm 13.8/15.7/11.8”
Weight 16 kg 35.5 lbs
The ELSD nitrogen gas generators use the pressure swing adsorption
(PSA) system, as used in thousands of systems worldwide to remove oxy-
gen, carbon dioxide and water from compressed air. The ELSD nitrogen
gas generators is incredibly miniaturized and very silent, ideal to be
placed in a little space like under or on a bench.
The ELSD gas generators are designed and manufactured within a rigor-
ous ISO9001 quality system.
Advantages:• Nitrogen produced at low pressure and ambient temperature removes
the need for high pressure cylinders or liquid dewars
• A constant, uninterrupted gas supply of guaranteed purity eliminates
interruptions of analyses to change cylinders and reduces the amount
of instrument re-calibrations required
• > 98% pure nitrogen gas produced as standard. Requires only com-
pressed air from an external source
• No high pressure cylinder requirement and very little moving part for
long term stable run without frequent maintenance demand. Profit
from in-house compressed air supply
• The gas generators can easily be installed in the laboratory
Model Description HiQ® code
ELSD-4000/230 ELSD PSA without compressor, 4 l/min, 230V 6014
ELSD-4000/110 ELSD PSA without compressor, 4 l/min, 110V 6015
MaintenanceELSD-8000K 8000 hours maintenance kit 6016
Certification: compliant
HiQ® ELSD nitrogen generator.
HiQ® ELSD nitrogen generator in principal.
Compressedair filter
Check valves
Purge line
CMStubes
Airinlet
N2 outlet
Nitrogenreservoir
Inletsolenoid
valves
Exhaust solenoid valves N2 pressure pumpand flow control
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.Nitrogen LC/MS Plus series.The nitrogen LC/MS Plus gas generator works with PSA technique. Including integral oil-free air compressors as standard, the generatordeliver a continuous stream of 99%+ pure nitrogen gas with a residual oxygen content of less than 1% at a flow rate of up to 35 liters perminute. The nitrogen LC/MS Plus gas generator is ideal for laboratory applications like all LC/MS techniques and other inert gas demandedapplications.
Technical data
Max. N2 flow rate (at 20°C, 1 bar and 99% purity)
35 l/min
Delivery pressure 8 bar 120 psi
N2 purity >99%
Oxygen content <1%
Index of protection IP2x (acc. IEC 60529, rev 2.1)
Temperature range 10–40 °C 50–104 °F
Noise level <58 dB(A)
Display Microprocessor controlled
graphic display, 128 x 64 pixels
Power 230V/50Hz 110V/60Hz
Fuse 10A/230V 14A/110V
Dimensions (W/D/H) 48/83.5/64 cm 19/33/25.2”
Weight 110 kg 242.5 lbs
The LC/MS Plus gas generators use a pressure swing adsorption (PSA)
system that removes oxygen, carbon dioxide and water from compressed
air. The standard PSA technology is combined with a dual step pressure
management. This allows to get high flow, high purity and high pressure
all together in a very economical way without stressing the components.
The nitrogen LC/MS Plus gas generators are designed and manufactured
within a rigorous ISO9001 quality system.
Advantages:
• Nitrogen produced at low pressure and ambient temperature removes
the need for high pressure cylinders or liquid dewars
• A constant, uninterrupted gas supply of guaranteed purity eliminates
interruptions of analyses to change cylinders and reduces the amount
of instrument re-calibrations required
• Up to 99%+ pure nitrogen gas produced as standard. No need for
costly downstream secondary filtration
• Integral oil-free air compressor guarantees continuous gas supply, in-
dependent of inhouse compressed air supply
• The gas generator can easily be installed in the laboratory
Model Description HiQ® code
LCMS-Plus-230 LC/MS N2, 35 l/min, 230V 6007
LCMS-Plus-110 LC/MS N2, 35 l/min, 110V 6008
MaintenanceLCMS-Plus-4000K 4000 hours maintenance kit 5986
Certification: compliant
HiQ® LC/MS Plus nitrogen generator.
HiQ® LC/MS Plus nitrogen generator in principal.
Coolingcoil
Compressedair filter
Check valves
Purge line
CMStubes
Air inletcompressor
PLC
N2 outlet
Nitrogenreservoir
Inlet solenoid
valves
Exhaust solenoid valves N2 pressure pumpand flow control
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.The nitrogen LC/MS 4 series.Nitrogen is commonly used in laboratories for different applications. Some demand higher purities, others are less purity-dependent. Suchapplications are typically nebulizing gas for liquid chromatography coupled with mass spectrometry (LC/MS). These are typically used forpolymer identification/determination, protein and peptide analysis/identification and in pharmaceutical research and development. Otherareas of application are specific solvent evaporations and low-purity purge gas requirements.
Technical data
Max. N2 flow rate 15–28 l/min (adjustable)
Delivery pressure 8.5 bar 120 psi
N2 purity 98–99% (adjustable)
Air quality Normal, clean ambient air,
relative humidity < 90%
Temperature range 10–35 °C 50–95 °F
Connections G ¼ / ¼ NPT
Noise level < 58 dB(A)
Flow capacity 10–30 Nl/m
Features
• Flow indication
• Pressure gauge
• Built-in compressors
• Built-in oxygen sensor
Power consumption 900W
Dimensions (W/D/H) 31/90/70 cm 12.2/35.4/27.6”
Weight 92.5 kg 204 lbs
The HiQ® LC/MS 4 laboratory nitrogen generator is specifically designed
to deliver larger capacity flow rates required for LC/MS 4 instrument op-
eration. The generator is a stand-alone unit that makes pure nitrogen out
of ambient air. The system is built around an integral membrane system
and oil-free direct drive compressors that deliver a continuous stream of
pure, dry nitrogen. The system can deliver flow rates from 1 to 30 Nl/m,
with purities ranging from 96% to 99.9%. For optimal floor mobility, the
units are equipped with self-locking caster wheels.
The built-in air compressor (stage 1) compresses the air up to 3.0 bar. The
first membrane tube removes the moisture and most of the oxygen to-
gether with other gases like CO2 (etc.). The permeate from the first mem-
brane tube is released back into the atmosphere. The pre-cleaned air
then passes on to the 2nd and 3rd membrane tube where nitrogen with a
purity higher than 98% is separated. The permeate from membrane tubes
2 and 3, which is moisture-free and reduced in oxygen content, is col-
lected and recycled back to the inlet of the low-pressure pump.
The pure nitrogen collected after tube 3 is then boosted by a second
compressor (stage 2) from 3.0 bar to 8.5 bar (45 psi to 120psi), which is
the outlet pressure specification.
Advantages:
• Flow control valve allows variable flow rates and nitrogen purity levels
• Pressure indication provided for nitrogen supply outlet
• Integral oxygen sensor monitors purity
• Standard integral oil-free direct drive air compressor for turnkey
operation
• Self-locking caster wheels provide mobility for installation
Model Description HiQ® code
LCMS-N2-4 LC/MS nitrogen generator with compressors 5535
Maintenance/spare partsLCMS-4-AK Maintenance kit for LC/MS 4 5536
LCMS-4-O2S Oxygen sensor for LC/MS 4 5537
Certification: compliant
HiQ® nitrogen LC/MS 4 generator.
HiQ® nitrogen LC/MS 4 generator in principal.
Air inlet
Membrane tubes Final pressure N2 pump
End pressure 8 bar (small volume)
Recycling permeate
Air compressor at 4 – 5 bar (high volume)Low pressure air pump
LC/MS 4 generator flow/purity graph
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.The nitrogen LC/MS 0 without compressor series.Nitrogen is commonly used in laboratories for different applications. Some demand higher purities, others are less purity-dependent. Suchapplications are typically nebulizing gas for liquid chromatography coupled with mass spectrometry (LC/MS). Other areas of application arespecific solvent evaporations and low-purity purge gas requirements.
Technical data
Max. N2 flow rate 25; 40; 60 l/min
Max. delivery pressure Inlet pressure ≈minus 1 bar (–15 psi)
N2 purity 98–99% (adjustable)
Compressed air feed specifications
Feed pressure 6–13 bar 90–190 psi
Temperature range 10–40 °C 50–104 °F
Residual oil content ≤ 0.01 mg/m3
Dew point < 5°C < 41°F
Connections G ¼”
Noise level < 45 dB(A)
Dimensions (W/D/H) 28/19/81 cm 11/7.5/31.9”
Weights
LCMS-0-N2-25 22 kg 49 lbs
LCMS-N2-0-40/60 35 kg 77 lbs
The HiQ® LC/MS 0 laboratory nitrogen generator is designed to deliver
larger capacity flow rates required for LC/MS instrument operation. The
generator is intended for use where compressed air is available from an
external source. No electrical installation is required. The system is built
around an integral membrane system and can deliver flow rates from 0 to
25 Nl/min with purities ranging from 98% to 99% (the higher flow the
lower purity and vice versa). The feed pressure must be within the range
of 7–10 bar (100 – 155 psi). For achieving best results the ambient air
pressure should be ~1013 mbar and the air feed temperature between
20–25 °C. The generator is delivered in a wall mounting cabinet.
Model Description HiQ® code
LCMS-N2-0-25 LC/MS N2 generator excl. compressor, 25 l/min 5924
LCMS-N2-0-40 LC/MS N2 generator excl. compressor, 40 l/min 6013
LCMS-N2-0-60 LC/MS N2 generator excl. compressor, 60 l/min 5926
MaintenanceLCMS-0-25-AK Filter kit for LCMS-N2-0-25 5925
LCMS-0-60-AK Filter kit for LCMS-N2-0-60 5927
Certification: compliant
HiQ® nitrogen LC/MS 0 generator without compressor.
HiQ® nitrogen LC/MS 0 generator without compressor in principal.
Air inlet10 bar (150 psi g) Nitrogen outlet
7 bar g (100 psi g)
Membrane tubes
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.The Ultra Zero Air series.Pure air is commonly used in the chromatographic world mainly as fuel for flames in detectors such as Flame Ionization Detectors (FIDs) andFlame Photometric Detectors (FPDs). The advantage with the Ultra Zero Air series is that it helps creating a truly flat baseline. The pure aircan be delivered in classic gas cylinders or be produced on site from oil-free compressed air. Designed with safety and convenience in mind,this system will generate purified and hydrocarbon-free air from an existing in-house oil-free compressed air supply.
Technical data
Max outlet flow 1.5; 3.0; 6.0; 15; 30 l/min
Max outlet pressure 6.5 bar 94 psi
Inlet air pressure range 4.5–10 bar 65–145 psi
Product outlet purity
Hydrocarbons < 0.1 ppm
Carbon dioxide < 5ppm
Carbon monoxide < 0.1 ppm
Nitrogen oxides < 0.1ppm
Sulfur oxide < 0.1ppm
Ozone < 0.1ppm
Dew point (< 2.5ppm) < 70°C < 158°F
Particles (>0.5 micron removed) 99.99%
Max inlet impurities
Hydrocarbons 100 ppm
Carbon dioxide 500ppm
Carbon monoxide 100 ppm
Nitrogen oxides 50ppm
Connections (compr. fitting) Out = ⅛” In = ¼”
Outlet air temperature (ambient) +15°C +59°F
Max inlet temperature +40°C +104°F
Dimensions (W/D/H) 47/25/40 cm
18/10/16”
Weights
ZAU 1500/3000 15 kg 33 lbs
ZAU 6000 21 kg 46 lbs
ZAU 15000/30000 25 kg 55 lbs
The Linde “ZAU” Ultra Zero Air generators reduce hydro carbons, nitrogen
oxides and sulphur dioxide pollutants to less than 0.1ppm, carbon diox-
ide to less than 5ppm and remove all kinds of particles. In the lab, they
provide several advantages. Eliminating the need to use and store high-
purity air in cylinders saves valuable laboratory floor space. The generator
can also be wall-mounted, providing yet another way of saving space.
Using an on-site gas generator also eliminates the need to recalibrate in-
struments after replacing empty cylinders with full ones. The operation of
the generator requires low levels of electrical power. This complete
turnkey system is engineered with the highest quality components, is
easy to install, and requires only minimal annual maintenance. The “ZAU”
Ultra Zero Air generator models utilize a 5-stage process to purify ambi-
ent air into high-purity analytical grade air. All main components are
manufactured with high-grade stainless steel and installed systematically
in cabinets for easy access and service.
Product features:
• Compact size requires minimal space
• Wall-mountable
• Built-in security lock on external housing
• Green, yellow and red indicating lights indicate power, warm-up,
ready and fault notification of low/high catalyst temperature,
low/high inlet pressure, and life expectancy/expiration of catalyst
• A digital thermal switch automatically shuts off the power supply to
the catalyst in the event that the inlet compressed air is turned off,
preventing catalyst damage due to overheating
Model Description HiQ® code
ZAU 1500 Ultra Zero Air generator 1,500ml/min 5765
ZAU 3000 Ultra Zero Air generator 3,000ml/min 5766
ZAU 6000 Ultra Zero Air generator 6,000ml/min 5767
ZAU 15000 Ultra Zero Air generator 15,000ml/min 5768
ZAU 30000 Ultra Zero Air generator 30,000ml/min 5769
Maintenance/optionsZA-FILT Replacement ext. air filter, housing and element 5770
ZA-XCART Replacement cartridge for external air filter 5771
ZA-ICART Replacement cartridge for internal air filter 5772
ZA-ACC-6 Active carbon column for models 1.5–6 l/min 5987
ZA-ACC-30 Active carbon column for models 15–30 l/min 5988
Certification: compliant
HiQ® Ultra Zero Air generator.
HiQ® Ultra Zero Air generator in principal.
Ultra ZeroAir outlet
Air inlet
CO2/CO/H2O remover
Filter
NOxremover
Filter
Catalytic
converter
480°C
Cooler
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.Zero Air generator with integral compressor.Pure air is commonly used in the chromatographic world mainly as fuel for flames in detectors such as Flame Ionization Detectors (FIDs) andFlame Photometric Detectors (FPDs). The pure air can be delivered in classic gas cylinders or be produced on site. Designed with safety andconvenience in mind, this system will generate purified and hydrocarbon-free air without the need of connecting to an external compressor.
Technical data
Max outlet flow 2.5 l/min
Max outlet pressure 5 bar 73 psi
Product outlet purity
Hydrocarbons < 0.1 ppm
Carbon monoxide < 0.1 ppm
Particles (>0.5 micron removed) 99.99%
Max inlet impurities
Hydrocarbons 100 ppm
Carbon monoxide 50 ppm
Outlet connection ⅛” NPTOutlet air temperature (ambient) +15° C +59° F
Max inlet temperature 40° C 104° F
Dimensions (W/D/H) 47/25/40 cm
18/10/16”
Weight 17 kg 37.5 lbs
The Linde “NGC” Zero Air generators reduce hydro carbon pollutants to
less than 0.1ppm and remove all kinds of particles. In the lab, they pro-
vide several advantages. Eliminating the need to use and store high-purity
air in cylinders saves valuable laboratory floor space. There is no need
to continually buy replacement high-purity air in cylinders. Using an on-
site gas generator also eliminates the need to recalibrate instruments
after replacing empty cylinders with full ones. The operation of the gen-
erator requires low levels of electrical power. This complete turnkey sys-
tem is engineered with the highest quality components, is easy to install,
and requires only minimal annual maintenance. The “NGC“ Zero Air gen-
erator models utilize a 3-stage process to purify ambient air into analytical
grade air. All main components are manufactured with high-grade stainless
steel and installed systematically in cabinets for easy access and service.
Product features:
• Compact size requires minimal space
• Wall-mountable
• Built-in security lock on external housing
• Green, yellow and red indicating lights indicate power, warm-up,
ready and fault notification of low/high catalyst temperature,
low/high inlet pressure, and life expectancy/expiration of catalyst
Model Description HiQ® code
NGC 2500 Zero Air generator with integral compressor 6009
MaintenanceNGC-AM Annual maintenance kit 6010
ZA-ACC-6 Active carbon column 5987
Certification: compliant
HiQ® Zero Air generator with compressor.
HiQ® Zero Air generator with integral compressor in principal.
Catalytic
Converter
480°C
Filter
Cooler
Condensor
CoolerFilter
Zero air outlet
Air compressor
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® specialty gas generators.The Zero Air series.Pure air is commonly used in the chromatographic world mainly as fuel for flames in detectors such as Flame Ionization Detectors (FIDs) andFlame Photometric Detectors (FPDs). The pure air can be delivered in classic gas cylinders or be produced on site from oil-free compressedair. Designed with safety and convenience in mind, this system will generate purified and hydrocarbon-free air from an existing in-house oil-free compressed air supply.
Technical data
Max outlet flow 1.5; 3.0; 6.0; 15; 30 l/min
Max outlet pressure 6.5 bar 94 psi
Inlet air pressure range 3–10 bar 45–145 psi
Product outlet purity
Hydrocarbons < 0.1 ppm
Carbon monoxide < 0.1 ppm
Particles (>0.5 micron removed) 99.99%
Max inlet impurities
Hydrocarbons 100 ppm
Carbon monoxide 100 ppm
Connections (compr. fitting) Out = ⅛” In = ¼”Outlet air temperature (ambient) +15° C 59° F
Max inlet temperature 40° C 104° F
Dimensions (W/D/H) 47/25/40 cm
18/10/16”
Weights
ZAGC 1500/3000 13 kg 29 lbs
ZAGC 6000 15 kg 33 lbs
ZAGC 15000/30000 22 kg 49 lbs
The Linde “ZAGC” Zero Air generators reduce HC pollutants to less than 0.1
ppm and remove all kinds of particles. In the lab, they provide several ad-
vantages. Eliminating the need to use and store high-purity air in cylinders
saves valuable laboratory floor space. There is no need to continually buy
replacement high-purity air in cylinders. Using an on-site gas generator
also eliminates the need to recalibrate instruments after replacing empty
cylinders with full ones. The operation of the generator requires low lev-
els of electrical power. This complete turnkey system is engineered with
the highest quality components, is easy to install, and requires only mini-
mal annual maintenance. The “ZAGC“ Zero Air generator models utilize a
3-stage process to purify ambient air into analytical grade air. All main com-
ponents are manufactured with high-grade stainless steel and installed
systematically in cabinets for easy access and service.
Product features:
• Compact size requires minimal space
• Wall-mountable
• Built-in security lock on external housing
• Green, yellow and red indicating lights indicate power, warm-up,
ready and fault notification of low/high catalyst temperature,
low/high inlet pressure, and life expectancy/expiration of catalyst
• A digital thermal switch automatically shuts off the power supply to
the catalyst in the event that the inlet compressed air is turned off,
preventing catalyst damage due to overheating
Model Description HiQ® code
ZAGC 1500 Zero Air generator 1,500ml/min 5760
ZAGC 3000 Zero Air generator 3,000ml/min 5761
ZAGC 6000 Zero Air generator 6,000ml/min 5762
ZAGC 15000 Zero Air generator 15,000ml/min 5763
ZAGC 30000 Zero Air generator 30,000ml/min 5764
Maintenance/optionsZA-FILT Replacement ext. air filter, housing and element 5770
ZA-XCART Replacement cartridge for external air filter 5771
ZA-ICART Replacement cartridge for internal air filter 5772
ZA-ACC-6 Active carbon column for models 1.5–6 l/min 5987
ZA-ACC-30 Active carbon column for models 15–30 l/min 5988
Certification: compliant
HiQ® Zero Air generator.
HiQ® Zero Air generator in principal.
Catalytic
Converter
480°C
Zero air outlet
Air inlet
Filter
Filter
Cooler
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Portable gas solutions.
In today’s industry, a broad range of gasesand chemicals are used. Especially at thechemical, pharmaceutical and biotech cus-tomers, a wide range of products isconsumed. Many of them are used as astarting point for chemical synthesis. Othersare used as intermediate product bringingbuilding blocks or might be used to catalystin chemical reactions.
Most processes and synthesis are first devel-
oped and tested on a lab scale. After proven
success, up-scaling is made by a pilot scale be-
fore it is produced on industrial scale. Both for
the lab scale as well as for the pilot scale,
smaller amounts of gases and chemicals are
used. These gases have often toxic or haz-
ardous properties, which require detailed
knowledge regarding storage, user conditions,
waste handling etc., both at the customers as
well as at the supplier.
Normally, these products are supplied in high
pressure or disposable gas cylinders. Depend-
ent on the consumption and the requested mo-
bility, the size of the cylinder might vary from
0.4 up to 10 liter water content. Mostly, only
very small amounts of product are needed.
Therefore, the smallest cylinder size available
(1 litre or less) contains normally more than
sufficient product.
With the Linde product line of small cylinders
we offer total solutions wherever light con-
tainer weight or only very small quantities of
gas is required. The product family:
• ECOCYL®RSH – portable calibration gas cylin-
der with integrated regulator
• ECOCYL® VAH-E/VSH-E – portable chemical
gas cylinder with integrated flow valve
Most suitable standard gases and gas mixtures
are available in small cylinders from current
production at short notice. To save both time
and expense, they are often shipped directly
from supplying plant or where and when per-
missible, by mail.
For you to find out what applies in your market
contact your local Linde representative.
HiQ® Specialty gas program.Equipment & gas distribution systems.
ECOCYL® RSH. Portable gas cylinder with integratedpressure regulator and flow valve.ECOCYL® RSH is the ultimate in safety, convenience and economics in portable calibration gas containers and delivery systems. The integratedvalve, regulator and flow meter is protected by a tough cowling made of polyacetal material.
Technical data
Max filling pressure 150 bar 2,200 psi
Outlet pressure 3.8 bar 55 psi
Outlet flow (fixed) 0.25, 0.3, 0.5, 1.0, 1.5, 2.5, 8.0 LPM
Outlet gauge range 0–200 bar 0–3,000 psi
Outlet connection 6 and 8 mm hose connection
Operating temperature –20 – +70°C –4 – +158°F
Cylinder volume 1 l
Weight (empty) 2.4 kg 5.3 lb
Diameter (max) 9.5 cm 3.7”
Height (overall) 44 cm 17”
Material
Cylinder Aluminum
Housing Stainless steel and aluminum
Seals Viton®
Piston Brass
Seating PCTFE
The refillable high capacity cylinder holds 50% more product than most
disposables, making the ECOCYL® RSH system an environmentally as well
as economically unsurpassed alternative.
The ECOCYL® RSH units are suited for non-corrosive pure gases as well as
gas mixtures that contain non-corrosive as well as corrosive components.
The ECOCYL® RSH units are not suited for pure oxygen, oxidizing gases or
oxidizing gas mixtures as well as liquefied flammable gases. The ECOCYL®
RSH can also be delivered with a convenient shoulder strap.
For full program and additional information of this supply solution, please
contact your local Linde representative.
ECOCYL® RSH
HiQ® Specialty gas program.Equipment & gas distribution systems.
ECOCYL® VAH and ECOCYL® VSH. Portable chemicalgas cylinder with integrated flow valve.Linde has developed a unique, small, refillable cylinder equipped with an integrated cylinder valve that has direct flow regulatingcapabilities. The unique design of the valve allows direct accurate flow adjustment without an additional flow regulator. This special is fullyintegrated into the cylinder’s protection cap. The result is a safe, easy and ready-to-use system. The user only needs to open the cylindervalve until the required flow has been reached. The ECOCYL® VAH and ECOCYL® VSH can also be delivered with a convenient shoulder strap.
Technical data
Max filling pressure 150 bar 2,200 psi
Max outlet pressure 150 bar 2,200 psi
Outlet flow variable and adjustable
by the main valve, gas dependent
Outlet connection 6 and 8 mm hose connection
Operating temperature –20 – +70°C –4 – +158°F
Cylinder volume 1 l
Weight (empty) 2.9 kg 6.4 lb
Diameter (max) 9.5 cm 3.7”
Height (overall) 39 cm 15.4”
Material
Cylinder Seemless stainless steel
Housing VAH Aluminum silicon bronze
Housing VSH Stainless steel
Seals VAH SIMRIZ®
VSH EPDM
Needle VAH SS 316
VSH NITRONIC® 50
ECOCYL® VAH is basically suited for all acid gases where the model
ECOCYL®VSH is suited for alkaline related gases. Both of them are suited
for most remaining gases, including those with an oxidizing potential.
With the ECOCYL® VAH and ECOCYL® VSH, Linde covers the business area
of truly portable cylinders with integrated equipment, fully protected by
a proper cylinder cowling.
The special regulating valves as used in Linde’s ECOCYL® VAH and
ECOCYL® VSH must be tested like normal cylinder valves, according EN-ISO
10297, to comply with the transportable pressure equipment directive
(TPED, European Council directive 1999/36/EC). Approved units are
signed with the Greek letter Π (pi), often followed by 4 digits.
For full program and additional information of this supply solution, please
contact your local Linde representative.
ECOCYL® VAH
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Cylinder types.
Gas cylinders are pressure vessels, and therefore governed by local authority rules and regulations.For full information, please contact your local Linde representative.
Seamless high-pressure cylinders, of steel or
aluminum, are used for compressed gases or
liquefied gases under pressure whose critical
temperature is TC <70 °C.
Cylinder bundlesCylinder bundles are larger transport units con-
sisting of 10 to 16 high-pressure cylinders fixed
in a steel frame and connected by pipes. Gas
filling and withdrawal is done through one com-
mon valve. A trailer contains of a large number
of firmly mounted cylinders on a coach.
Welded low-pressure cylinders, of sheet steel,
are used for liquefied gases under pressure
whose TC ≥70 °C when this is permitted.
Welded steel casks are also available for these
gases. They are clamped in a steel frame and
may be transported by road.
Returnable cylindersFollowing is a selection of different returnable
cylinders that Linde Gas can provide. For pre-
cise information on what is valid for your mar-
ket, contact your local Linde representative.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Int. volumelitre
Material TypeTare weight Pressure rating
HiQ® codekg lb bar(a) psi(g)
0.4 NS HD 1.7 200 001
0.4 NS LB 1.8 200 002
1.0 NS LBS 1.0 124 003
1.0 AL A01 3.03 2216 004
1.0 AL AL001 2.1 200 005
1.0 TS HD/S 2.0 200 006
1.0 TS OTC-1 2.0 200 007
1.0 AL OTM-1 1.5 200 008
1.5 NS LBR 2.41 1800 009
2.0 NS 02C 2.87 1800 010
2.0 AL AL002 3.2 200 011
2.0 TS B02 3.5 200 012
2.0 AL B02A 2.4 200 013
2.0 TS HD 5.3 200 014
2.0 AL HD/S 4.7 200 015
2.0 AL OTM-2 3.0 200 016
2.5 TS OTC-2.5 3.0 200 017
3.0 TS 003 9.5 2015 018
3.0 NS GFL-3 5.0 150 019
4.0 TS OTC-4 42.0 200 020
4.6 SG L04 12 240 021
5.0 TS 005 13.5 2015 022
5.0 AL AC5-150 3.7 150 023
5.0 NS GFL-5 8.0 150 024
5.0 NS SC5-150 7.4 150 025
5.0 TS AG5 9.0 200 026
5.0 AL AL005 7.5 200 027
5.0 TS B05 8.5 200 028
5.0 AL B05A 7.4 200 029
5.0 AL BALU05 7.0 200 030
5.0 TS OTC-5 7.0 200 031
5.0 AL OTM-5 7.0 200 032
5.0 TS ST005 8.5 200 033
5.0 TS T05 8.0 200 034
5.8 SG A07 10.0 15 035
6.0 AL 3AL2265 6.6 150 036
7.0 SG ND 4.0 21 037
7.0 NS DOT3A2015 5.0 139 038
7.0 TS 007 29 2015 039
7.0 NS IRAM2525-7 5.0 150 040
7.0 AL A07 14.43 2215 041
10.0 TS HD/A 21.0 18 042
10.0 SS ND/S 21.0 40 043
10.0 AL AL-10 14.0 140 044
10.0 NS GFL-10 13.0 150 045
10.0 NS HD/K 19.0 150 046
Cylinder types.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Int. volumelitre
Material TypeTare weight Pressure rating
HiQ® codekg lb bar(a) psi(g)
10.0 TS AG10 14.0 200 047
10.0 TS AL010 12.0 200 048
10.0 TS B10 17.5 200 049
10.0 AL B10A 138.0 200 050
10.0 TS BACE10 20.0 200 051
10.0 AL BALU10 13.0 200 052
10.0 TS HD 16.0 200 053
10.0 AL HD/S 11.5 200 054
10.0 SS HD/S 32.0 200 055
10.0 TS OTC-10 15.0 200 056
10.0 AL OTM-10 12.0 200 057
10.0 TS ST010 14.0 200 058
13.4 TS B13,4 17.5 200 059
14.0 SG P-6 10.4 25 060
15.0 AL B15A 16.2 200 061
16.0 NS DOT3AA2015 5.0 134 062
16.0 TS 016 53 2015 063
16.0 AL A16 30 2015 064
20.0 TS HD/A 38.0 18 065
20.0 SS ND/S 17.0 43 066
20.0 AL 3AL2015 10.6 140 067
20.0 NS GFL-20 32.0 150 068
20.0 TS AG20 33.0 200 069
20.0 AL AL020 30.0 200 070
20.0 AL AL020HO 26.0 200 071
20.0 TS B20 30.0 200 072
20.0 AL B20A 21.6 200 073
20.0 TS B20MB 30.0 200 074
20.0 AL B2ALU20 23.0 200 075
20.0 TS BACE20 37.0 200 076
20.0 TS OTC-20 27.0 200 077
20.0 AL OTM-20 24.0 200 078
20.0 TS ST020 28.0 200 079
20.0 TS T20 30.0 200 080
20.0 TS T20MB 30.0 200 081
21.3 NS 3AL2015 18.0 140 082
21.7 SG L20 17 240 083
22.0 NS AC22-150 17.6 150 084
23.0 SG DG-ETNº2 25.0 22 085
26.0 SG P-11 14.0 25 086
26.7 TS B26,6 38.0 200 087
26.7 TS OTC-26.7 25.8 200 088
27.0 SG ND 12.0 21 089
29.4 AL 3AL2015 21.6 140 090
30.6 SG P13 20.0 30 091
31.0 AL AL-31 24.0 140 092
MaterialAL: aluminumNS: steel with minimum
yield point of 390 N/mm2
SG: sheet steel, weldedSS: stainless steelTS: temper hardened steel
HiQ® Specialty gas program.Equipment & gas distribution systems.
Cylinder types.
Int. volumelitre
Material TypeTare weight Pressure rating
HiQ® codekg lb bar(a) psi(g)
31.0 AL A31 49 2015 093
40.0 SG A60 50.0 15 094
40.0 TS HD/A 60.0 19 095
40.0 NS AC40 45.0 60 096
40.0 NS HD/K 78.0 150 097
40.0 TS HD/S 48.0 150 098
40.0 NS SC40-150 71.0 150 099
40.0 NS ST040 70.0 150 100
40.0 TS B40 61.0 200 101
40.0 TS BACE40 65.0 200 102
40.0 TS GFL-40 58.0 200 103
40.0 AL HD/S 45.0 200 104
40.0 SS HD/S 81.0 200 105
40.0 TS IN40 45.0 200 106
40.0 TS IRAM2525-4 58.0 200 107
40.0 TS OTC-40 55.0 200 108
40.0 AL OTM-40 45.0 200 109
40.0 TS TW40 51.4 200 110
40.0 TS B-40 67.0 201 111
43.0 TS 043 187 3500 112
43.4 SG L40 33.6 240 113
44.0 AL E10047 54.0 150 114
44.0 NS SC44-150 74.9 150 115
44.0 NS 3AA2265 53.0 156 116
44.0 TS 044 110 2265 117
45.0 SG P-19 21.0 25 118
46.0 TS 046 300 6000 119
47.0 SS ND/S 50.0 40 120
49.0 NS 3AA2400 64.0 165 121
49.0 TS 049 143 2400 122
50.0 SG R50H 100.0 0.5 123
50.0 SG A70 75.0 15 124
50.0 SG ACET50 85.0 18 125
50.0 SG L-50 26.0 25 126
50.0 SS ND/S 31.0 43 127
50.0 NS 3AA2900 73.0 200 128
50.0 TS AG50 63.0 200 129
50.0 AL AL050 58.0 200 130
50.0 TS B50 61.0 200 131
50.0 AL B50A 49.2 200 132
50.0 TS B50MB 61.0 200 133
50.0 AL BALU50 56.0 200 134
50.0 TS BS/5045/1 60.0 200 135
50.0 TS GFL-50 68.0 200 136
50.0 TS HD 67.0 200 137
50.0 TS IRAM2525-5 63.0 200 138
HiQ® Specialty gas program.Equipment & gas distribution systems.
MaterialAL: aluminumNS: steel with minimum
yield point of 390 N/mm2
SG: sheet steel, weldedSS: stainless steelTS: temper hardened steel
Int. volumelitre
Material TypeTare weight Pressure rating
HiQ® codekg lb bar(a) psi(g)
50.0 TS OTC-50 65.0 200 139
50.0 AL OTM-50 57.0 200 140
50.0 TS SC50-165 65.0 200 141
50.0 TS SC50-200 65.0 200 142
50.0 TS ST050 70.0 200 143
50.0 AL B50C 33.6 250 144
50.0 TS HD/S 93.0 300 145
53.6 TS OTC-53.6 50.5 200 146
54.0 SG 054 85 480 147
56.0 SG CS56-Acet 34.0 20 148
61.0 SG 061 177 480 149
64.8 SG L60 48 240 150
67.0 TS B67 70.0 200 151
79.0 SG ND 35.0 21 152
83.0 SG P35 50.0 30 153
84.0 SG B84 50.0 30 154
102.6 SG R20H 120.0 0.5 155
107.0 SG P-45 38.0 25 156
108.0 SG L-108 50.0 25 157
110.0 SG DOT4BW240 10.0 16 158
110.0 SG 110 68 240 159
126.0 SG D126 47.0 21 160
126.0 SG 126 150 480 161
160.0 SG VGL160-11 115.0 11 162
175.0 SG R20MP 175.0 10 163
180.0 SS VGL180--11 115.0 11 164
200.0 SG DOT 4L292 127.0 20 165
400.0 TS Maxi 850.0 200 166
450.0 TS 450 1108 1800 167
454.0 SG DOT4BW240 170.0 16 168
454.0 SG 454 315 240 169
480.0 AL BL/E/S 960.0 200 170
480.0 AL BL/M/S 960.0 200 171
500.0 TS PKT-10x50L 750.0 200 172
600.0 SG CP6MP 560.0 10 173
600.0 TS BL/M 1057.0 200 174
600.0 TS PKT-12x50S 950.0 200 175
600.0 TS BL/E/S 1100.0 300 176
650.0 AL PAK13X50 1130.0 200 177
761.0 SG 761 1077 500 178
800.0 TS PAK16X50 1370.0 200 179
800.0 TS SuperMaxi 1450.0 200 180
950.0 TS F 566.0 22 181
Note that low pressure cylinders are often filled by weight and therefore the internal volume and work pressure is not an
indication of filling volume.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Equipment connections, tubings and fittings.
Washer valve
Washer
Outletthread
Diaphragm valve
Diaphragm
Outletthread
The purpose of the cylinder valve is to openand shut the gas cylinder, it is not meant toregulate the gas flow.
The cylinder valve is normally made of brass,
unless the chemical properties of the gas de-
mands another material such as steel or stain-
less steel.
The valve can be equipped with a dip tube for
withdrawal of liquid phase from liquefied gases.
For certain liquefied gases the valve is
equipped with a burst disk for safety.
Diaphragm valves are used for high purity gases
and specialty gas mixtures with low component
contents of for example reactive components.
Cylinder valves for highly reactive and toxic
gases are in some countries equipped with a
safety valve. This kind of valve normally has an
incorporated flow restrictor. Certain cylinder
valves are equipped with pneumatic function to
operate them, explosion safe, from a distance.
To avoid gas cylinder being connected to the
wrong gas supply system, the cylinder valves
are equipped with different outlet threads, de-
pending on the gas content of the cylinder. The
rules deciding what threads go with what gas
are governed by local authorities, and differ
from country to country.
On the following 4 pages some of the most
common cylinder valve outlets are described.
The term INT refers to internal outlet threads of
the cylinder connection, if not stated the thread
is external. The term LH refers to left-handed
threads, if not stated the thread is right-handed.
The chemical properties of the gas govern what
cylinder valve material – brass, steel or stainless
steel – is most suitable.
Cylinder valves & inlet connections.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Cylinder connections
Inlet connections.
ABNT 245-1 AFNOR C
ABNT DescriptionHiQ®
inlet code
ABNT 172-1 3/8-18 NSPL 043
ABNT 172-1 hand connector 3/8-18 NSPL 122
ABNT 218-1 W 21.8 x 1/14" 045
ABNT 218-1 hand connector W 21.8 x 1/14" 123
ABNT 218-2 W 21.8 x 1/14" INT 050
ABNT 218-2 hand connector W 21.8 x 1/14" INT 124
ABNT 225-2 0.885" - 14 NGO 046
ABNT 225-2 hand connector 0.885" - 14 NGO 125
ABNT 245-1 0.960" - 14 NGO 044
ABNT 245-1 hand connector 0.960" - 14 NGO 126
ABNT 245-2 0.965" - 14 NGO 049
ABNT 245-2 hand connector 0.965" - 14 NGO 127
ABNT 262-1 1.035" - 14 NGO 048
ABNT 262-1 hand connector 1.035" - 14 NGO 128
ABNT 270-9 W 24.44 x 2" 047
ABNT 270-9 hand connector W 24.44 x 2" 129
ABNT 300-12 W 27.44 x 2" 051
ABNT 300-12 hand connector W 27.44 x 2" 130
AFNOR DescriptionHiQ®
inlet code
NF C SI 21.7 x 1.814 055
NF C hand connector SI 21.7 x 1.814 157
NF D W 24 x 2 056
NF D hand connector W 24 x 2 158
NF E SI 21.7 x 1.814 LH 057
NF E hand connector SI 21.7 x 1.814 LH 159
NF F SI 22.94 x 1.814 INT 059
NF F hand connector SI 22.94 x 1.814 INT 160
NF G SI 26 x 1.5 INT 060
NF G hand connector SI 26 x 1.5 INT 161
NF H W 22.91 x 1.814 LH INT 061
NF H hand connector W 22.91 x 1.814 LH INT 162
NF J W 25.4 x 3.175 062
NF J hand connector W 25.4 x 3.175 163
NF K W 27 x 2 063
NF K hand connector W 27 x 2 164
NF L W 27 x 2 064
NF L hand connector W 27 x 2 165
NF M W 30 x 2 065
NF M hand connector W 30 x 2 166
NF P W 27 x 2 067
NF P hand connector W 27 x 2 167
HiQ® Specialty gas program.Equipment & gas distribution systems.
Cylinder connections
BS 341 No. 8 CGA 170
CGA DescriptionHiQ®
inlet code
CGA 110 0.3125 - 32 UNEF INT 019
CGA 110 hand connector 0.3125 - 32 UNEF INT 014
CGA 170 9/16" - 18 UNF INT 201
CGA 170 hand connector 9/16" - 18 UNF INT 202
CGA 180 5/8" - 18 UNF INT 021
CGA 180 hand connector 5/8" - 18 UNF INT 020
CGA 240 3/8" - 18 NPT 024
CGA 240 hand connector 3/8" - 18 NPT 072
CGA 296 0.803" - 14 UNS INT 203
CGA 296 hand connector 0.803" - 14 UNS INT 204
CGA 300 0.825" - 14 NGO 205
CGA 300 hand connector 0.825" - 14 NGO 206
CGA 320 0.825" - 14 NGO 077
CGA 320 hand connector 0.825" - 14 NGO 028
CGA 326 0.825" - 14 NGO 026
CGA 326 hand connector 0.825" - 14 NGO 131
CGA 330 0.825" - 14 NGO LH 016
CGA 330 hand connector 0.825" - 14 NGO LH 132
CGA 346 0.825" - 14 NGO 176
CGA 346 hand connector 0.825" - 14 NGO 177
CGA 350 0.825" - 14 NGO LH 013
CGA 350 hand connector 0.825" - 14 NGO LH 133
CGA 510 0.855" - 14 NGO LH INT 002
CGA 510 hand connector 0.855" - 14 NGO LH INT 134
CGA 540 0.903" - 14 NGO 078
CGA 540 hand connector 0.903" - 14 NGO 135
CGA 580 0.965" - 14 NGO INT 052
CGA 580 hand connector 0.965" - 14 NGO INT 136
CGA 590 0.965" - 14 NGO LM INT 017
CGA 590 hand connector 0.965" - 14 NGO LM INT 137
CGA 660 1.030" - 14 NGO 018
CGA 660 hand connector 1.030" - 14 NGO 138
CGA 679 1.030" - 14 NGO LH 207
CGA 679 hand connector 1.030" - 14 NGO LH 208
CGA 705 1.125" - 14 UNS LH 178
BS 341 DescriptionHiQ®
inlet code
BS 341 No. 2 G 5/8" LH 179
BS 341 No. 2 hand connector G 5/8" LH 180
BS 341 No. 3 G 5/8" INT 181
BS 341 No. 3 hand connector G 5/8" INT 182
BS 341 No. 4 G 5/8" LH INT 183
BS 341 No. 4 hand connector G 5/8" LH INT 184
BS 341 No. 6 G 5/8" 185
BS 341 No. 6 hand connector G 5/8" 186
BS 341 No. 7 G 5/8" LH 187
BS 341 No. 7 hand connector G 5/8" LH 188
BS 341 No. 8 W 0.860" x 14 TPI 189
BS 341 No. 8 hand connector W 0.860" x 14 TPI 190
BS 341 No. 10 G 1/2" 191
BS 341 No. 10 hand connector G 1/2" 192
BS 341 No. 12 G 1/2" 199
BS 341 No. 12 hand connector G 1/2" 200
BS 341 No. 13 W 11/16" - 20 TPI 193
BS 341 No. 13 hand connector W 11/16" - 20 TPI 194
BS 341 No. 14 G 3/8" 195
BS 341 No. 14 hand connector G 3/8" 196
BS 341 No. 15 G 3/8" LH 197
BS 341 No. 15 hand connector G 3/8" LH 198
HiQ® Specialty gas program.Equipment & gas distribution systems.
DIN 477 DescriptionHiQ®
inlet code
DIN 477 No. 1 W 21.8 x 1/14" LH 001
DIN 477 No. 1 hand connector W 21.8 x 1/14" LH 140
DIN 477 No. 2 W 21.8 x 1/14" LH 209
DIN 477 No. 2 hand connector W 21.8 x 1/14" LH 210
DIN 477 No. 3 Yoke 095
DIN 477 No. 3 hand connector Yoke 147
DIN 477 No. 5 W 1" x 1/8" LH 003
DIN 477 No. 5 hand connector W 1" x 1/8" LH 148
DIN 477 No. 6 W 21.8 x 1/14" 004
DIN 477 No. 6 hand connector W 21.8 x 1/14" 149
DIN 477 No. 7 G 5/8" 005
DIN 477 No. 7 hand connector G 5/8" 151
DIN 477 No. 8 W 1" x 1/8" 006
DIN 477 No. 8 hand connector W 1" x 1/8" 152
DIN 477 No. 9 G 3/4" 007
DIN 477 No. 9 hand connector G 3/4" 153
DIN 477 No. 10 W 24.32 x 1/14" 008
DIN 477 No. 10 hand connector W 24.32 x 1/14" 142
DIN 477 No. 11 G 3/8" 009
DIN 477 No. 11 hand connector G 3/8" 143
DIN 477 No. 12 G 3/4" INT 010
DIN 477 No. 12 hand connector G 3/4" INT 144
DIN 477 No. 13 R 5/8" 011
DIN 477 No. 13 hand connector R 5/8" 145
DIN 477 No. 14 M 19 x 1.5 LH 012
DIN 477 No. 14 hand connector M 19 x 1.5 LH 146
DIN 477 No. 52 M 30 x 1.5 INT 211
Inlet connections.
Cylinder connections
DIN 477 No. 14 IRAM 2539 o
IRAM 2539 DescriptionHiQ®
inlet code
IRAM 2539i 5/8" BSP - INT 053
IRAM 2539i hand connector 5/8" BSP - INT 154
IRAM 2539 C2H2 3/4" BSPx1/14" INT 096
IRAM 2539 N2O 3/8" BSPx1/14" 097
IRAM 2539 N2O hand connector 3/8" BSPx1/14" 155
IRAM 2539 o W 21.8 - 14 054
IRAM 2539 o hand connector W 21.8 - 14 156
ISO 5145 DescriptionHiQ®
inlet code
ISO 5145 No. 0170 M 30 x 2 212
HiQ® Specialty gas program.Equipment & gas distribution systems.
Cylinder connections
NEN 3268 LU1
UNI 4406
UNI DescriptionHiQ®
inlet code
UNI 4405 W 20 x 1/14" Sin. 213
UNI 4405 hand connector W 20 x 1/14" Sin. 214
UNI 4406 W 21.7 x 1/14" 215
UNI 4406 hand connector W 21.7 x 1/14" 216
UNI 4409 W 21.7 x 1/14" 217
UNI 4409 hand connector W 21.7 x 1/14" 218
UNI 4412 W 24.5 x 1/14" 219
UNI 4412 hand connector W 24.5 x 1/14" 220
NEN 3268 DescriptionHiQ®
inlet code
LU 0 M 19 x 1.5 LH 115
LU 0 hand connector M 19 x 1.5 LH 168
LU 1 W 21.8 - 1/14 LH 116
LU 1 hand connector W 21.8 - 1/14 LH 169
LU 4 W 1" LH 117
LU 4 hand connector W 1" LH 170
RI 2 G 5/8" INT 121
RI 2 hand connector G 5/8" INT 171
RU 1 W 21.8 - 1/14 118
RU 1 hand connector W 21.8 - 1/14 172
RU 3 W 24.32 - 1/14 119
RU 3 hand connector W 24.32 - 1/14 173
RU 4 W 1" 120
RU 4 hand connector W 1" 174
3 - MIE - AP7 DescriptionHiQ®
inlet code
MIE B M 30 x 1.75 221
MIE B hand connector M 30 x 1.75 222
MIE C W 21.7 x 1/14" 223
MIE C hand connector W 21.7 x 1/14" 224
MIE E W 21.7 x 1/14" LH 225
MIE E hand connector W 21.7 x 1/14" LH 226
MIE F G 5/8" INT 227
MIE F hand connector G 5/8" INT 228
MIE G M 26 x 1.5 INT 083
MIE G hand connector M 26 x 1.5 INT 175
MIE H G 5/8" LH INT 229
MIE H hand connector G 5/8" LH INT 230
MIE J W 1" 231
MIE J hand connector W 1" 232
MIE M M 19 x 1.5 LH 233
MIE M hand connector M 19 x 1.5 LH 234
MIE S G 5/8" 235
MIE S hand connector G 5/8" 236
MIE T W 31.75 x 1/7" 237
MIE T hand connector W 31.75 x 1/7" 238
MIE U G 3/8" 239
MIE U hand connector G 3/8" 240
3-MIE C
HiQ® Specialty gas program.Equipment & gas distribution systems.
Outlet connections.Linde offers a wide range of outlet connections from the most well acknowledged manufacturers. The table below shows some of the mostcommonly used designs and dimensions. For special arrangements or needs, please contact your local Linde representative.
Outlet connectionsHiQ®
outlet code
3 mm, stainless steel 501
6 mm, stainless steel 502
8 mm, stainless steel 503
10 mm, stainless steel 504
12 mm, stainless steel 505
1/8”, stainless steel 506
1/4”, stainless steel 507
3/8”, stainless steel 508
1/2”, stainless steel 509
3 mm, brass 510
6 mm, brass 511
8 mm, brass 512
10 mm, brass 513
12 mm, brass 514
1/8”, brass 515
1/4”, brass 516
3/8”, brass 517
1/2”, brass 518
Illustration showing a typical straight outlet connection (male NPT – compression fitting).
HiQ® Specialty gas program.Equipment & gas distribution systems.
Tubings.To ensure the integrity of the gas, from thegas cylinder to the point of use, stainlesssteel tubing is used when installing a centralgas supply system for specialty and highpurity gases.
Linde uses AISI 316L SS tubes according to EN
10216-5 and ASTM A 269 in three different
quality classes.
Fittings.For joining various parts and components tothe central gas supply system Linderecommends the use of high quality fittings.
For systems up to a purity of 5.5 Linderecommends tube fittings (e.g. Parker A-LOK®, Swagelok® or Gyrolok®). These fittingsavoids any extra torque on the piping.
For systems above a purity of 5.5 Linde recom-
mends the use of metal gasket face seal fittings
(e.g. VCRR), which enables a tightness equiva-
lent to 10-9 cm3 He/s. The seal of a metal gas-
ket face seal is made when the gasket is
compressed by two polished beads when the
fitting is tightened. A metal gasket face seal can
not be disassembled and reassembled without
replacing the metal gasket.
Quality level
class 1 class 2 class 3
Surface finish Ra 0.2 µm certified Ra 0.4 µm certified Ra 1.0 µm
Electro polish Yes — —
Cleaning– Plugshooting
Flushing with water80°C 18MΩ/cm
Flushing with 0.5MΩ/cm water atroom temperature
Flushing with 0.5MΩ/cm water atroom temperature
Purging Detector nitrogen 5.5 with 0.003 µm filter
TestingMoisture analysis, particlemeasurement
— —
Plugged andpacked
Ends sealed with nylonfilm and PE caps. Packedin double plastic bags inclass 10/100 clean room.
Ends protected withPE caps. Packed inplastic bags.
Ends protected withPE caps. Packed inplastic bags.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Accessories.
To handle gases and gas cylinders, one needfrom time to time some additional items.
Some of these items are found in this chapter.
Please contact your local Linde representative
for your full local accessories program.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Centralized monitoring systems.Monitoring systems can be divided into two components: data collectors, such as contact gauges and pressure transducers, and datapresenters, such as a centralized monitoring system. Data collectors can work without data presenters, but not vice versa. The alarm systemworks as an automatic pressure supervisor. the system is EEx(i)-classified according to EN 500 20, and consists of a central unit, an EEx(e)classified alarm box, an extension box, if necessary, and 1–8 contact gauges.
Technical data
Size (W/H/D) 213/185/113 mm
Material
Casing ABS plastic
Cover Clear polycarbonate
Supply voltage 230 V, 50 Hz
Supply current 0.5 A
Channels 1 (expandable to max. 4)
Indication lights
Green Normal pressure
Red Low pressure/switch-over
Historically, contact gauges connected to a centralized monitoring system
have been dominant, but the use of transducers connected to a PLC-sys-
tem is becoming increasingly common. Linde has wide experience of
working with contact gauges and centralized monitoring systems.
The central unit is placed outside the potentially explosive zone. The unit
incorporates an electronic device that indicates low pressure in the con-
nected gas cylinders. At low pressure a buzzer signal sound and a light
diode is activated.
The alarm box is placed inside the potentially explosive zone. The alarm
incorporates an EExe-classified sealing, with an amplifier for the intrinsic
safe signal. The central unit is connected to the alarm box by a 12-con-
nector cable. The cable supplies the signal amplifier with 24 VDC, and
carries the signal from alarm and contact gauge to the central unit.
There may be an extension box between the alarm box and the contact
gauge, to make it possible to place several gas cylinders at different dis-
tances from the alarm box inside the potentially explosive zone.
The system can be expanded by up to three extra channels.
Product name HiQ® code
Central monitoring system kit 3389
HiQ® Specialty gas program.Equipment & gas distribution systems.
Contact gauges & Pressure transducers.Contact gauges are used to monitor when a pre-set pressure is reached. These can be delivered EEx-classified.
Pressure transducers monitor changes in pressure and can be used in place of contact gauges – necessary if the signal must be connected toa central computer or a PLC. The high output current (4–20 mA) may require the transducer to be isolated if used in an explosive environment.
Technical data – Contact gauge
Accuracy ≤ 2.5% of max pressure
Hysteresis ≤ 2.5% of max pressure
Electrical
Voltage ≤ 24 V
Current ≤ 500 mA
Operating temperatures
Ambient –25 – +60 °C –15 – +140 °F
Media –25 – +100 °C –15 – +210 °F
Connection G ¼”
Pressure range 0–25 bar 0–400 psi
0–60 bar 0–900 psi
0–250 bar 0–3,600 psi
Connection NPT ¼”
Pressure range 0–16 bar 0–250 psi
0–60 bar 0–900 psi
0–250 bar 0–3,600 psi
Product name HiQ® code
Contact gauge 3391
Pressure transducer 6012
Contact gauge
Pressure transducer
HiQ® Specialty gas program.Equipment & gas distribution systems.
Mounting bracket.Primarily for use with the BASELINE™ R 104/1 line regulator (page 126).
Technical data
Material Stainless steel
Product name HiQ® code
Mounting bracket 6011
Mounting bracket
47.1
120.7
25.4
50.8
12.7
All measurements in millimeters.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Wall mounting bracket & gas cylinder trolley.Linde delivers a selection of practical wall mounting brackets and cylinder trolleys for different needs. These might vary depending on yourlocal market. Please contact your local Linde representative for more information.
Wall mounting bracket for gas cylinders
Gas cylinder trolley
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Gas Supply System Installations.
The success of an installation project liesvery much in the planning of the project.There are many details that have to fall inplace to minimize the project time and makeit successful. Linde have prepared some
checklists to aid in planning a gas supplysystem installation projects. They are meantto simplify and make sure that everything iscovered during an installation.
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Gas Supply System Installations. Checklist.
Checklist – Supply
Gas
Type of gas and gas quality
Pressure: – Gas panel
– Main piping system,
standard 10–15 bar
– In- and outlet pressure to point-
of-use regulator
Flow: – Each point-of-use regulator
– Total system
Storage
– Preferably in a separate building or container
– Different kinds of gases shall be separated
– Heating of storage area
– Electrical installation
Checklist – Equipment
Point-of-use
– Type of regulator etc
– Material
– Inlet connection
– Outlet connection
– Safety outlet
Gas panel
– Single or semi-automatic
– Material
– Contact gauges/pressure transducers
– Purging system
– Number of cylinders
– Inlet connection
– Outlet connection
– Outlet pressure
– Flow shut-off valve
– Safety outlet
Checklist – Piping
Tubing
– Quality
– Dimensions
– Number of welding fittings, reducers,
elbows, tees
Valves
– Material
– Main shut off valve
– Section shut off valve
– Relief valves etc
– Check valves
Other equipment
– Filters
– Purifiers
– Monitoring central
– Gas cabinets
– Gas detection units
Checklist – Installation
Installation material
– Tube clamps
– Mark tags and signs
– Welding gas
– Purge gas
– Pressure test gas
– Leak detection gas
Installation items
– New or existing building
– Making holes in walls, floors and ceilings
– Electric installation
– Patch up and painting after installation
– Fireproof sealing of holes
– Need of skylift etc.
– Lockable storage room
– Safety outlet tube
– Pressure test
– Leak test
Checklist – Miscellaneous
Miscellaneous
– Inactive time
– Travelling cost
– Hotel
– Allowance for expenses
– Training
– Drawings and documentation
– Operating instructions
– Limit of engagement
– Labor management
– Service
– Guarantee
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Services.
Linde delivers a variety of services, both customer-specific and standardized. Below is someinformation on different services. The service portfolio is often based on the local demandand customer specific ideas and requirements; therefore you should contact your local Linderepresentative to receive all information about the full portfolio for your market and aboutsolutions specifically designed for your needs. Please also contact your local Linde office ifyou have ideas on services not covered here.
eBusiness and web orderingWouldn’t you like more timesaving tools to help
do your job?
• Want to web order with real-time material
availability and see your pricing?
• Need to know how much you spend on a
blanket purchase order?
• How do you know if that credit was given or
not?
• Has your company decided to place orders
through a marketplace or other procurement
solution?
• Do you know your present cylinder balance?
With Linde you can do these things and many
other things whenever you want. We at Linde
have listened to our customers and offer them
access to the features and capabilities most de-
sired. Various eBusiness tools and systems have
been implemented throughout the Linde world,
to more efficiently conduct your business and
provide service. In most cases, these business
tools have been directly integrated with the
local business systems to improve speed, accu-
racy and convenience.
Online ordering is available on many Linde mar-
kets. Online ordering is available for customers
who register for access. With registration, one
or more users at each company are authorized
to be the web administrator. Buyers using the
web ordering get so many advantages:
• Pre-loaded past purchase history organized
into modifiable reorder templates.
• Reorder in less than 1 minute – from old or-
ders or reorder template.
• Pre-negotiated prices and payment terms
are used and shown.
• Material availability shown before placing
order, when applicable.
• Add items from online catalog to an order.
• Delivery instructions specific to the ship-to
location are shown.
• Automatic email confirmation with complete
order details.
Many Linde companies can offer a variety of
eBusiness tools, to find out what is applicable
for you, please contact your local Linde repre-
sentative.
HiQ® Specialty gas program.Equipment & gas distribution systems.
ACCURA®
The new real-time ACCURA® Cylinder Manage-
ment system takes the benefits of cylinder
monitoring even further, bringing them to you
over the Internet!
A new tool for cylinder gas management in
your company
ACCURA® Cylinder Management collects cylin-
der gas data in a format that your company can
easily manage and utilize. It’s a system that can
save your company thousands – maybe tens of
thousands of euros per year.
ACCURA® Cylinder Management operates via
the Internet, and it’s a tool designed for anyone
who needs to know what types of gases they
have in stock, where gas cylinders are located
and also how to develop cylinder procedures.
The service is planned in co-operation with the
customer, and is tailored to the company’s op-
erating model. This ensures that it serves all
departments - Stock, Production and Safety as
well as Purchasing and Finance.
Effective risk management
One of the major benefits of ACCURA® Cylinder
Management is that it will remind and inform
you. If you wish, the system will monitor unin-
terrupted gas availability for you.
With access to real-time information for all your
stock, you can plan for variations in gas con-
sumption and ensure your processes operate
without interruption.
In emergency situations e.g., in the event of a
fire, Cylinder Management will tell you the lo-
cation of your cylinders as well as cylinder
numbers.
Benefits of Cylinder Management
• Gas cylinders are used effectively, which
saves money
• Gas consumption budgeting and planning is
improved
• Cost reporting and internal allocation is easier
• Invoice checking and processing is faster
• Cylinder Management will warn you of any
expiring gases
Clear, versatile reports
– Gas in stock
– Cylinder movement history
– Gas utilization
– Gas consumption
– Gas and rental costs
– Gas costs split per warehouse
– Cylinder rotation
– Daily rental costs
– Rental agreements
– Expiring gases
– Hazardous gases
SECCURA™Consider these questions:
Have you ever experi-
enced running out of gas
because the person re-
sponsible for checking and
ordering simply forgot to
do so? Or failed to do it be-
cause of some misunder-
standing or mix-up? If the
gas you’re dependent on
suddenly ran out, what
problems would it create
for your company, and
your customers?
Increased production
reliability – a real value
SECCURA™ automatic gas
supply is a supply service
that allows you to forget completely how much
gas you have at any given time. As the name
indicates, this service runs automatically. When
a cylinder or a bundle is empty and needs
changing, an automatic ordering signal is sent
directly to Linde. We will see that replacements
are installed. Your staff won’t even have to
know it has been done.
Reducing unnecessary costs – saving real
money
SECCURA™ automatic gas supply completely
eliminates the need to check, order, and re-
place gas cylinders and bundles. In most cases
it also eliminates the need to keep extra cylin-
ders in stock “just in case.”
Increased convenience – a true value
SECCURA™ automatic gas supply lightens your
load by effectively removing the cause of worry
and increasing your convenience. This service
from Linde allows you to spend your resources
where they are most needed. And leaves you
free to focus your energy on production.
Hardly a “luxury”…
Services.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Increased safety – an invaluable value
SECCURA™ automatic gas supply means that
our trained drivers do all the tasks involved
with the changing of cylinders and bundles, in-
cluding testing for leaks and changing gaskets
when required. They do it every day – and they
do it right. Your staff is not concerned and the
task does not interfere with their safety in any
way.
Safety audits, walkthroughs and trainingsConcerned about the safety of your existing
specialty gas distribution system? Wondering if
your system is designed and operated in accor-
dance with today’s standards? Linde can help.
Conduct safety audits and plant walkthroughs
Linde can perform a complete safety assess-
ment of your existing gas system. We will re-
view the overall system’s design, evaluate your
associated operating procedures and training
program, evaluate mitigation and containment
systems, and review maintenance practice. We
provide both recommendations for system im-
provements and identify areas that are out of
compliance with applicable safety codes.
Specialty gas safety training
In order to increase safety, reduce downtime,
and to help prevent unwanted releases, Linde
can offer custom designed specialty gas equip-
ment/system trainings, often including:
• Product safety and equipment training
• Operator training, including theory of opera-
tion
• Maintenance training
To support our training programs, we develop
applicable operating and maintenance proce-
dures and student material. Courses can be
structured as class room/instructor lead, self-
study, and on-the-job. Linde also offers the ad-
ditional services:
• Regulatory compliance/Site surveys
• Technical support
• Emergency response team
• On-Site support
Application safety training
Typically with a new process application, days
of assistance for start-up and training are pro-
vided. This training would be onsite for plant
personnel. Typical the training covers safety,
maintenance and operation.
Gas analysis serviceLinde gas is one of the largest gas suppliers in
the world. As such we have a network of highly
skilled laboratories to verify and secure the
quality of our own production. These can of
course be utilized for gas specific analysis serv-
ices.
The typical assignments are either investiga-
tions of a single gaseous source e.g., a smoke
stack, or periodic measurement for companies
that do not have or can justify the necessary in-
strument park. Many local Linde markets have
access to mobile laboratory units that enable
analysis at customer
location. When this is
impossible, our skilled
chemists know all
about gathering rep-
resentative samples
and bring them back
to the laboratory.
Here follows a selection of available analysis
methods:
• Time-of-flight Atmospheric Pressure Ioniza-
tion Mass Spectrometer to measure down to
ppt range
• A variety of Gas Chromatographs equipped
with general (WLD, TCD, HeID) and specific
detectors (FID, ECD, Argon detector, Hall de-
tector, Helium detector and Chemo lumines-
cent detector)
• Chemo luminescent analyzer for NOX
• Gas chromatographs with cold trap tech-
nique to measure hydrocarbons in the ppb
range
• Laser based particle analyzer
• High resolution FTIR with long path gas cu-
vette
• NDIR analyzers for different gases
• Moisture analyzers (dew point mirror and
capacitive method)
• Pure oxygen analyzers (electrochemical and
phosphor luminescent)
• UV/VIS spectrometry
• AES (Atomic emission spectrometry)
HiQ® Specialty gas program.Equipment & gas distribution systems.
Services.
HiQ® analysis certificateLinde’s gas production and laboratory facilities
perform professional and skillful quality control
and analysis of gas mixtures. It is of vital impor-
tance that the results are correct, since they
often are the base for monitoring/measuring
e.g., process conditions, quality levels and
safety conditions. It is also important that all
the information on the analysis certificate is
correct and easy to understand.
Linde always follows the latest update of the
ISO 6141 standard, specifying the information
on an analysis certificate. The HiQ® Analysis
Certificate from Linde is in accordance with this
standard. The HiQ® Analysis Certificate always
looks the same. The information is easy to lo-
cate and understand. The headings are in the
appropriate language and in English, allowing
the certificate to be used both in the relevant
country and across borders. All gas products are
quality controlled. Where applicable, an analy-
sis certificate is included in the product. If not
included, it can be requested separately. Please
check with your local Linde office to find out
what is applicable for the products you order.
Name HiQ® code
HiQ® Analysis certificate
(Certified standard) 2921
Explanations on the HiQ® Analysis Certificate
1 The date when the certificate was written,
the beginning of the shelf life
2 Identification of the HiQ® Certificate
3 Type of HiQ® certificate e.g., “Certificate of
Analysis,” “Certificate of Conformity”, etc.
4 HiQ® product name and code when applica-
ble
5 Comments on the table
– the unit can be given either in mole, volume
or weight
– the uncertainty refers to the analysis of
each component and is relative
– if an absolute uncertainty is given it is In the
column “Analysis result” (for instance 202 ±
4 ppm)
6 Confidence level is the probability of the
analysis result falling between the uncer-
tainty limits
7 The blend tolerance of a gas mixture speci-
fies how close to the ordered concentration
the final concentration must fall
8 Following the temperature recommendation
improves safety and helps to keep the gas
mixture homogeneous
9 The component concentrations will remain
within the limits stated in the analysis result
down to the recommended minimum pres-
sure of use
10 Use before: In a correctly handled cylinder
the component concentrations will remain
within the limits stated in the analysis result
during the stated shelf life
Reference materialCalibration certificate
National borders no longer define today’s envi-
ronment. Pollutions are monitored on regional
and even global scale. This requires that the re-
sults from the monitoring systems shall not only
be comparable, but also mutually acceptable.
Governments use accreditation as an instru-
ment in these regulatory issues. Also in trading
of goods, a confident and trustful base is
needed to qualify and quantify the value of the
traded goods. Accreditation is widely accepted
as a tool to address issues like competence and
reliability. Calibration certificates are used as a
base to facilitate easy trading.
Reference material with a calibration certificate
is analyzed at a laboratory that has accredited
analysis methods for the components and
ranges in question.
Several Linde facilities have such accredited
analysis methods, especially for components
and ranges used for environmental surveil-
lance. Linde laboratories are accredited as cali-
bration laboratories. Further, several facilities
are accredited as testing laboratories to facili-
tate analytical services.
The reference materials prepared by these pro-
duction facilities are acknowledged as standard
reference material by e.g., CAI, COFRAC, DAR,
ENAC, RVA, SWEDAC, UKAS and many others.
These products are in accordance with ISO
17025. An accreditation proves that the labo-
ratory is competent to perform a certain analy-
sis. The competence of the laboratory is
decisive for the accreditation, and to achieve
an accreditation it is mandatory to have a qual-
HiQ® Specialty gas program.Equipment & gas distribution systems.
ity system. Linde specialty gas plants are ISO
9000 certified.
Please contact your local Linde office for more
information on how Linde can serve you with
reference material and services that are related
to the ISO 17025 standard.
Name HiQ® code
Certificate of calibration reference
material (ISO 17025) 2920
Other reference material
Reference materials and certified materials are
defined in ISO Guide 30. A reference material
(RM) is a material that is sufficiently estab-
lished to be used, for example, for the calibra-
tion of an apparatus.
A certified reference material (CRM) is a refer-
ence material whose property values are certi-
fied by a technically valid procedure and/or
traceable to a certificate or other documenta-
tion that is issued by a certifying body.
Industries such as the automotive industry are
very dependent on clearing their products
against local environmental legislation, for in-
stance the rules of EPA in the US. EPA demands
that calibration mixtures are traceable against
National Institute for Standards and Technology
(NIST). NIST and the Nederlands Meetinstituut
(NMi) have a bilateral agreement on recogni-
tion of each other’s mixtures that is ratified by
EPA. Linde can supply you with products trace-
able to standards from various national certified
bodies such as BAM, NMi, NPL and NIST.
Most of Linde’s mixtures are produced gravi-
metrical and are therefore traceable to the in-
ternational kilo. Should this be one of your
requirements and the product is not produced
in this manner, traceability to the kilo can be
obtained upon request.
Please contact your local Linde office for more
information on how Linde can provide you with
reference material.
Name HiQ® code
Certified body traceable analysis
certificate (Traceable to e.g., BAM, NIST,
NMi, NPL etc.) 2916
Kilogram traceable certificate
(Primary standard) 2918
EPA protocolThe EPA has established the EPA protocol – strict
guidelines for the performance of standard ma-
terials for emission measurements. In addition
to the automotive industry standard product
program EPA protocol mixtures, Linde can de-
liver EPA protocol gases for other purposes.
Please contact your local Linde office for more
information on how Linde can provide you with
EPA protocol gases.
Name HiQ® code
EPA protocol certificate 2919
Certificate of conformitySeveral processes and activities do not require
individual analytical results. However, it might
be important to guarantee that the product
used complies with its nominal specifications.
Linde can provide a certificate of conformity
stating that an individual cylinder or an entire
batch is meeting its specifications. Please con-
tact your local Linde office for more information
on how Linde can serve you with certificates of
conformity.
Name HiQ® code
Certificate of conformity 6322
HiQ® Specialty gas program.Equipment & gas distribution systems.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Physical data.
Physical and chemical information on puregases.
The aim throughout has been to present in a
condensed form as large amount of accurate,
reliable and up-to-date information on the
fields of chemistry and physics for pure gases.
Chemistry and physics, always closely related
sciences, have been brought into more intimate
relations by more recent results and research
discoveries. The information contained herein
can be used for a variety of tasks such as
recalculation between volume and weight at a
fixed temperature.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name Chemical
formula
Molecular
weight
g/mol
Liquid state
Density
(at b.p. 1 atm)
kg/l
Density
(20 °C)
kg/l
Vapor
pressure
(20 °C) bar
Specific
heat
kJ • kg-1 • K-1
Acetylene C2H2 26.038 0.6179 0.3999 43.41 3.64 (15 °C)
Air, synthetic 28.96 — — — —
Ammonia NH3 17.031 0.6814 0.6091 8.56 4.4 (–40 °C)
Argon Ar 39.948 1.3974 — — 1.1 (b.p.)
Arsine AsH3 77.945 1.6205 1.3401 14.75 —
Boron trichloride BCl3 117.17 1.3457 1.3291 1.32
Boron trifluoride BF3 67.806 1.5716 — — —
1,3-Butadiene C4H6 54.092 0.6508 0.6211 2.40 2.22 (15 °C)
n-Butane C4H10 58.123 20.602 0.5788 2.08 2.35 (15 °C)
iso-Butane C4H10 58.123 0.5949 0.5585 3.06 1.92 (15 °C)
1-Butene C4H8 56.107 0.6261 0.5944 2.57 2.25 (15 °C)
cis-2-Butene C4H8 56.107 0.6416 0.6227 1.81 —
iso-Butene C4H8 56.107 0.6274 0.5951 2.64 0.67 (15 °C)
trans-2-Butene C4H8 56.107 0.6275 0.6053 1.99 —
Carbon dioxide CO2 44.01 1.1806 0.774 57.37 1.97 (–20 °C)
Carbon monoxide CO 28.01 0.790 — — 0.68 (b.p.)
Carbonyl sulfide COS 60.076 1.1769 1.0068 11.06 —
Chlorine Cl2 70.905 1.5622 1.4128 6.80 2.06 (b.p.)
Cyanogen chloride CNCl 61.47 1.1969 1.1823 1.35 —
Cyclopropane C3H6 42.081 0.6989 0.626 6.29 —
Deuterium D2 4.032 0.1605 — — —
Diborane B2H6 27.67 0.4288 — — —
Dichlorosilane SiH2Cl2 101.01 1.2014 1.1773 1.52 —
Dimethylamine (CH3)2NH 45.084 0.6704 0.6559 1.69 3.02 (0 °C)
Dimethyl ether C2H6O 46.069 0.7296 0.6633 5.09 —
2,2-Dimethylpropane C5H12 2.59 0.6036 0.5918 1.46 —
Ethane C2H6 30.07 0.5447 0.3385 37.70 3.79 (15 °C)
Ethene C2H4 28.054 0.5698 — — —
Ethylene oxide C2H4O 44.053 0.8827 0.8696 1.47 —
Ethylamine C2H5NH2 45.084 0.6869 0.6828 1.15 —
Ethyl chloride C2H5Cl 64.514 0.9064 0.8967 1.34 —
Fluorine F2 37.997 1.5056 — — —
Helium He 4.003 0.124 — — 4.01 (b.p.)
Hydrogen H2 2.016 0.0705 — — 8.78 (b.p.)
Hydrogen bromide HBr 80.912 2.1521 1.7571 21.80 0.92 (15 °C)
Hydrogen chloride HCl 36.461 1.1933 0.8231 42.02 1.70 (b.p.)
Hydrogen fluoride HF 20.006 0.9552 0.954 1.03 —
Hydrogen sulphide H2S 34.082 0.943 0.7886 18.41 1.06 (21 °C)
Krypton Kr 83.8 2.4186 — — —
Methane CH4 16.043 0.4241 — — 3.45 (b.p.)
Methylamine CH3NH2 31.057 0.6946 0.6617 2.96 3.28 (-14 °C)
Methyl bromide CH3Br 94.939 1.7196 1.6755 1.84 —
Methyl chloride CH3Cl 50.487 1.0073 0.9232 4.96 1.57 (20 °C)
Methyl mercaptan CH3SH 48.109 0.8875 0.8689 1.70 1.85 (b.p.)
Neon Ne 20.18 1.2039 — — 1.85 (b.p.)
Nitric oxide NO 30.006 1.2808 — — 2.61 (b.p.)
Nitrogen N2 28.014 0.8078 — — 2.06 (b.p.)
Nitrogen dioxide NO2 46.006 1.453 1.4552 0.96 1.55 (b.p.)
Nitrogen trifluoride NF3 71.002 1.540 — — —
Nitrous oxide N2O 44.013 1.2225 0.7848 51.27 1.74 (b.p.)
Physical data.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name Chemical
formula
Molecular
weight
g/mol
Liquid state
Density
(at b.p. 1 atm)
kg/l
Density
(20 °C)
kg/l
Vapor
pressure
(20 °C) bar
Specific
heat
kJ • kg-1 • K-1
Octafluoropropane C3F8 188.02 1.6047 1.345 7.69 0.97 (b.p.)
Oxygen O2 31.999 1.142 — — 1.68 (b.p.)
Phosgene COCl2 98.916 1.4021 1.3743 1.59 —
Phosphine PH3 33.998 0.7437 0.5071 35.17 —
Propadiene C3H4 40.065 0.663 0.587 6.34 —
Propane C3H8 44.097 0.583 0.5011 8.39 2.22 (b.p.)
Propene C3H6 42.081 0.6103 0.5112 10.25 2.57 (15 °C)
Propyne C3H4 40.065 0.6721 0.6142 4.94 —
R 11 Trichlorofluoromethane CFCl3 137.37 1.4795 1.4884 0.89 0.89 (30 °C)
R 12 Dichlorodifluoromethane CF2Cl2 120.91 1.4858 1.3251 5.63 0.98 (30 °C)
R 13 Chlorotrifluoromethane CF3Cl 104.46 1.5229 0.9279 31.89 1.04 (-30 °C)
R 13 b1 Bromotrifluoromethane CF3Br 148.91 1.9927 1.5725 14.34 0.88 (25 °C)
R 14 Tetrafluoromethane CF4 88.005 1.6067 — — —
R 21 Dichlorofluoromethane CHFCl2 102.92 1.4057 1.3794 1.53 0.98 (b.p.)
R 22 Chlorodifluoromethane CHF2Cl 86.468 1.4122 1.2125 8.97 1.28 (30 °C)
R 23 Trifluoromethane CHF3 70.014 1.4514 0.8109 41.98 6.50 (25 °C)
R 114 1,2-Dichlorotetrafluorethane C2Cl2F4 170.92 1.5184 1.4706 1.84 1.03 (30 °C)
R 115 Chloropentafluoroethane C2ClF5 154.47 1.5448 1.3114 8.00 1.19 (30 °C)
R 116 Hexafluoroethane C2F6 138.01 1.5979 — — —
R 134a Tetraflouroethane C2H2F4 102.03 1.375 1.224 5.71 1.40 (15 °C)
R 142b 1-Chloro-1,1-difluoroethane C2H3ClF2 100.5 1.2002 1.1213 2.90 —
R 152a 1,1-Difluoroethane C2H4F2 66.051 1.0141 0.9103 5.18 —
Silane SiH4 32.117 0.5826 — — —
Silicon tetrafluoride SiF4 104.08 — — — —
Sulphur dioxide SO2 64.065 1.4628 1.3808 3.36 —
Sulphur hexafluoride SF6 146.06 1.8449 1.3744 21.61 0.67 (21 °C)
Trimethylamine (CH3)3N 59.111 20.6552 0.6349 1.83 —
Tungsten hexafluoride WF6 297.84 3.430 — 1.10 —
Vinyl bromide C2H3Br 106.95 1.523 1.512 1.18 0.90 (15 °C)
Vinyl chloride C2H3Cl 62.499 0.9658 0.9115 3.42 1.35 (20 °C)
Vinyl methyl ether C3H6O 58.08 0.7699 0.7508 1.74 2.14 (0 °C)
Xenon Xe 131.29 2.9537 — — 0.34 (b.p.)
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name Rel. spec. wgt,
air = 1
(15 °C, 1 bar)
Density
(15 °C, 1 atm)
kg/m3
Gaseous state
Specific heat
(15 °C)
kJ • kg-1 • K-1
Thermal
conductivity
µW • cm-1 • K-1
Solubility in water
(at P = 1 bar)
l/kg
Acetylene 0.91 1.109 1.663 187 (0 °C) 0.999 (20 °C)
Air, synthetic 1.0 1.21 1.01 255 (0 °C) 0.018
Ammonia 0.59 0.728 2.071 221 (0 °C) 692 (15 °C)
Argon 1.38 1.691 0.52 175 (0 °C) 0.033 (20 °C)
Arsine 2.73 3.334 0.488 116 (0 °C) 0.20 (20 °C)
Boron trichloride 4.19 5.162 0.526 86 (15 °C) hydrolyzed
Boron trifluoride 2.35 2.882 0.733 157 (0 °C) —
1,3-Butadiene 1.94 2.359 1.447 132 (0 °C) 0.230 (20 °C)
n-Butane 2.09 2.547 1.647 138 (0 °C) 0.034 (20 °C)
iso-Butane 2.08 2.537 1.611 140 (0 °C) 0.032 (20 °C)
1-Butene 2.01 2.449 1.489 130 (0°C) —
cis-2-Butene 2.00 2.457 1.374 125 (15 °C) —
iso-Butene 2.01 2.448 1.553 144 (0 °C) —
trans-2-Butene 2.00 2.455 1.533 134 (15 °C) —
Carbon dioxide 1.53 1.872 0.834 146 (0 °C) 0.851 (20 °C)
Carbon monoxide 0.97 1.185 1.04 232 (0 °C) 0.022 (20 °C)
Carbonyl sulfide 2.11 2.574 0.683 122 (0 °C) —
Chlorine 2.49 3.042 0.477 80 (0 °C) 2.3 (20 °C)
Cyanogen chloride 2.18 2.678 0.733 90 (15 °C) —
Cyclopropane 1.48 1.812 1.27 143 (0 °C) —
Deuterium 0.14 0.171 7.215 1,301 (0 °C) —
Diborane 0.97 1.181 2.031 210 (0 °C) —
Dichlorosilane 3.60 4.426 0.603 97 (15 °C) hydrolyzed
Dimethylamine 1.60 1.965 1.511 157 (15 °C) 119 (60 °C)
Dimethyl ether 1.63 1.988 1.416 141 (0 °C) —
2,2-Dimethylpropane 2.59 3.193 1.614 140 (15 °C) —
Ethane 1.05 1.283 1.723 180 (0 °C) 0.047 (20 °C)
Ethene 0.98 1.194 1.496 180 (0 °C) 0.120 (20 °C)
Ethylene oxide 1.55 1.911 1.054 121 (15 °C) —
Ethylamine 1.61 — 1.572 (20 °C) 162 (20 °C)
Ethyl chloride 2.29 2.819 0.944 108 (15 °C) 1.99 (20 °C)
Fluorine 1.31 1.608 0.819 238 (0 °C) —
Helium 0.14 0.169 5.193 1,460 (0 °C) 0.0083 (20 °C)
Hydrogen 0.07 0.0852 14.242 1,606 (0 °C) 0.0182 (20 °C)
Hydrogen bromide 2.82 3.45 0.36 79 (0 °C) 467 (25 °C)
Hydrogen chloride 1.27 1.552 0.799 134 (0 °C) 440 (20 °C)
Hydrogen fluoride 0.71 — 1.456 (20 °C) — —
Hydrogen sulphide 1.19 1.454 1.00 129 (0 °C) 2.5 (20 °C)
Krypton 2.90 3.552 0.248 88 (0 °C) 0.061 (20 °C)
Methane 0.55 0.68 2.201 300 (0 °C) 0.033 (20 °C)
Methylamine 1.10 1.34 161 191 (0 °C) 757 (25 °C)
Methyl bromide 3.34 4.106 0.439 71 (15 °C) —
Methyl chloride 1.78 2.173 0.791 92 (0 °C) 3.4 (0 °C)
Methyl mercaptan 1.70 2.084 1.028 127 (15 °C) 11.2 (15 °C)
Neon 0.70 0.853 1.03 461 (0 °C) 0.010 (20 °C)
Nitric oxide 1.04 1.27 0.999 235 (0 °C) 0.046 (20 °C)
Nitrogen 0.97 1.185 1.04 235 (0 °C) 0.015 (20 °C)
Nitrogen dioxide 2.75 — 0.815 (25 °C) — hydrolyzed
Nitrogen trifluoride 2.46 3.015 0.75 (25 °C) — —
Nitrous oxide 1.53 1.873 0.868 155 (0 °C) 0.610 (20 °C)
Physical data.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name Rel. spec. wgt,
air = 1
(15 °C, 1 bar)
Density
(15 °C, 1 atm)
kg/m3
Gaseous state
Specific heat
(15 °C)
kJ • kg-1 • K-1
Thermal
conductivity
µW • cm-1 • K-1
Solubility in water
(at P = 1 bar)
l/kg
Octafluoropropane 6.53 8.163 0.769 100 (0 °C) —
Oxygen 1.11 1.354 0.916 242 (0 °C) 0.030 (20 °C)
Phosgene 3.50 4.308 0.577 83 (15 °C) —
Phosphine 1.18 1.449 1.079 192 (0 °C) 1.16 (24 °C)
Propadiene 1.41 1.725 1.467 136 (0 °C) —
Propane 1.56 1.901 1.642 159 (0 °C) 0.039 (20 °C)
Propene 1.48 1.809 1.498 150 (0 °C) 0.182 (20 °C)
Propyne 1.42 1.728 1.487 137 (0 °C) —
R 11 Trichlorofluoromethane 4.92 — 0.567 (25 °C) 78 (25 °C) 0.180 (25 °C)
R 12 Dichlorodifluoromethane 4.29 5.231 0.589 84 (0 °C) 0.051 (25 °C)
R 13 Chlorotrifluoromethane 3.65 4.465 0.629 107 (0 °C) 0.019 (25 °C)
R 13 b1 Bromotrifluoromethane 5.23 6.396 0.457 86 (0 °C) 0.004 (25 °C)
R 14 Tetrafluoromethane 3.05 3.737 0.68 133 (0 °C) 0.004 (25 °C)
R 21 Dichlorofluoromethane 3.65 4.493 0.582 81 (15 °C) 2.070 (25 °C)
R 22 Chlorodifluoromethane 3.04 3.719 0.644 92 (0 °C) 0.775 (25 °C)
R 23 Trifluoromethane 2.44 2.986 0.719 109 (0 °C) 0.313 (25 °C)
R 114 1,2-Dichlorotetrafluorethane 6.12 7.532 0.673 105 (15 °C) 0.017 (25 °C)
R 115 Chloropentafluoroethane 5.48 6.687 0.687 110 (0 °C) 0.008 (25 °C)
R 116 Hexafluoroethane 4.84 5.912 0.755 299 (0 °C) —
R 134a Tetraflouroethane 3.53 4.415 0.827 113 (0 °C) —
R 142b 1-Chloro-1,1-difluoroethane 3.59 4.378 0.804 101 (0 °C) —
R 152a 1,1-Difluoroethane 2.34 2.857 1.002 102 (0 °C) —
Silane 1.12 1.366 1.307 — insoluble
Silicon tetrafluoride 3.61 4.431 0.696 — —
Sulphur dioxide 2.26 2.759 0.617 85 (0 °C) 38.2 (20 °C)
Sulphur hexafluoride 5.12 6.261 0.647 116 (0 °C) 0.005 (25 °C)
Trimethylamine 2.10 2.59 1.514 143 (15 °C) —
Tungsten hexafluoride 10.60 — 0.379 (25 °C) — —
Vinyl bromide 3.72 4.653 0.509 88 (0 °C) —
Vinyl chloride 2.21 2.703 0.841 105 (0 °C) —
Vinyl methyl ether 2.03 2.537 1.334 157 (15 °C) —
Xenon 4.56 5.586 0.158 52 (0 °C) 0.120 (20 °C)
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name
Boiling point (1 atm) Critical point Flammability in air
Temperature
°C
Heat of
vaporization
kJ/kg
Temperature
°C
Pressure
bar
Density
kg/l
Lower
limit
% volume
Upper
limit
% volume
Acetylene –84.15 634.2 35.17 61.391 0.2305 2.2 85.0
Air, synthetic — — –141.7 36.6 0.331 — —
Ammonia –33.43 1,369.8 132.5 112.78 0.235 15.0 27.0
Argon –185.87 161.2 –122.29 48.981 0.5356 n.a. n.a.
Arsine –62.48 211.5 99.85 65.500 0.797 5.8 n.a.
Boron trichloride 12.5 204.3 178.8 38.706 0.7899 n.a. n.a.
Boron trifluoride –99.8 254.3 –12.25 49.852 0.5486 n.a. n.a.
1,3-Butadiene –4.41 415.6 152.22 43.299 0.2449 2.0 12.0
n-Butane –0.5 386 152.03 37.969 0.228 1.8 8.4
iso-Butane –11.72 368.1 134.99 36.480 0.2213 1.8 8.4
1-Butene –6.25 400 146.44 40.196 0.2339 1.6 10.0
cis-2-Butene 3.72 417.6 162.43 42.058 0.2398 1.7 9.7
iso-Butene –6.89 395.9 144.75 39.990 0.2349 1.8 9.6
trans-2-Butene 0.88 408.2 155.48 41.024 0.2356 1.7 9.7
Carbon dioxide — 347.6 31.04 73.815 0.4682 n.a. n.a.
Carbon monoxide –191.45 211 –140.23 34.988 0.3009 12.5 74.0
Carbonyl sulfide –50.15 311.7 105.65 63.490 0.4447 12.0 29.0
Chlorine –34.03 287.9 144 77.108 0.573 n.a. n.a.
Cyanogen chloride 12.85 435 175.85 59.900 0.3771
Cyclopropane –32.78 477.2 124.76 55.749 0.2585
Deuterium –249.5 293.2 –234.8 16.617 0.0669 5.0 75.0
Diborane –92.5 516.8 16.65 40.530 0.1599 0.9 98.0
Dichlorosilane 8.3 249.5 175.85 44.300 0.443 4.1 98.8
Dimethylamine 6.88 590.8 164.5 53.094 0.2411 2.8 14.4
Dimethyl ether –24.84 468.1 126.95 53.702 0.271 3.4 27.0
2,2-Dimethylpropane 9.5 315.2 160.63 31.992 0.2377 1.4 7.5
Ethane –88.6 488.5 32.27 48.801 0.2033 3.0 12.4
Ethene –103.68 479.9 9.21 50.318 0.2174 3.1 32.0
Ethylene oxide 10.7 583.3 196.0 71.941 0.314 3.0 100.0
Ethylamine 16.58 606.6 183.0 56.235 0.2477
Ethyl chloride 12.27 383.6 187.2 52.689 0.3226
Fluorine –188.2 171.7 –128.84 52.152 0.574 n.a. n.a.
Helium –268.93 20.8 –267.95 2.2750 0.0699 n.a. n.a.
Hydrogen –252.76 442.8 –239.97 13.130 0.0314 4.0 74.5
Hydrogen bromide –66.7 223.2 90 85.518 0.807 n.a. n.a.
Hydrogen chloride –85 444.6 51.5 83.087 0.450 n.a. n.a.
Hydrogen fluoride 19.52 49.7 188 64.848 0.2899 n.a. n.a.
Hydrogen sulphide –60.35 554.2 100.38 89.629 0.3461 4.0 44.0
Krypton –153.35 108.4 –63.8 55.020 0.9189 n.a. n.a.
Methane –161.49 508.9 –82.57 46.043 0.1616 5.0 15.0
Methylamine –6.33 840.7 156.9 74.575 0.2017 4.9 20.7
Methyl bromide 3.56 255.7 193.85 80.000 0.6086 10.0 16.0
Methyl chloride –24.22 426.8 143.1 66.793 0.3632 10.7 17.4
Methyl mercaptan 5.96 510.8 196.8 72.346 0.3318 4.0 22.0
Neon –246.06 84.8 –228.75 26.530 0.4839 n.a. n.a.
Nitric oxide –151.77 451.6 –93 64.848 0.520 n.a. n.a.
Nitrogen –195.8 197.9 –147.05 33.944 0.3109 n.a. n.a.
Nitrogen dioxide 20.85 828.5 158.2 101.33 0.5577 n.a. n.a.
Nitrogen trifluoride –129 163 –39.15 42.28 0.568 n.a. n.a.
Nitrous oxide –88.48 390.9 36.42 72.447 0.452 n.a. n.a.
Physical data.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name
Boiling point (1 atm) Critical point Flammability in air
Temperature
°C
Heat of
vaporization
kJ/kg
Temperature
°C
Pressure
bar
Density
kg/l
Lower
limit
% volume
Upper
limit
% volume
Octafluoropropane –36.75 104.8 71.9 26.8 0.6718 n.a. n.a.
Oxygen –182.98 213.3 –118.57 50.430 0.436 n.a. n.a.
Phosgene 7.56 250.5 181.85 56.742 0.520 n.a. n.a.
Phosphine –87.74 412.2 51.6 65.355 0.300
Propadiene –34.5 514.1 120 54.700 0.2473
Propane –42.04 426.3 96.67 42.492 0.2174 2.2 9.5
Propene –47.69 438.8 92.42 46.650 0.2234 2.0 10.5
Propyne –23.21 555.3 129.24 56.276 0.2443 1.7 12.0
R 11 Trichlorofluoromethane 23.82 183.1 198.05 44.076 0.5539
R 12 Dichlorodifluoromethane –29.79 170.4 111.8 41.249 0.5572 n.a. n.a.
R 13 Chlorotrifluoromethane –81.41 149.4 28.81 39.460 0.5794 n.a. n.a.
R 13 b1 Bromotrifluoromethane 57.89 117.7 67 39.719 0.7446 n.a. n.a.
R 14 Tetrafluoromethane –128.06 132.8 –45.65 37.389 0.6286 n.a. n.a.
R 21 Dichlorofluoromethane 8.9 239.4 178.43 51.838 0.5251 n.a. n.a.
R 22 Chlorodifluoromethane –40.83 233.5 96.15 49.710 0.5209 n.a. n.a.
R 23 Trifluoromethane –82.16 237.3 25.74 48.362 0.5252 n.a. n.a.
R 114 1,2-Dichlorotetrafluorethane 3.77 135.4 145.7 32.627 0.582 n.a. n.a.
R 115 Chloropentafluoroethane –39.11 125.1 80 31.573 0.613 n.a. n.a.
R 116 Hexafluoroethane –78.2 116.8 19.65 29.790 0.6161 n.a. n.a.
R 134a Tetraflouroethane –26.0 216.6 101.15 40.64 0.5687 n.a. n.a.
R 142b 1-Chloro-1,1-difluoroethane –10.01 223.5 137.05 41.239 0.4351 9.0 15.0
R 152a 1,1-Difluoroethane –25.8 329 113.45 44.988 0.3649 4.0 18.0
Silane –112.15 387.8 3.450 48.433 0.242 1.0 100
Silicon tetrafluoride — 142.9 –14.15 37.186 0.6308 n.a. n.a.
Sulphur dioxide –10.02 385.4 157.6 78.841 0.5251 n.a. n.a.
Sulphur hexafluoride –63.9 111 45.54 37.600 0.7357 n.a. n.a.
Trimethylamine 2.87 396.6 160.1 40.733 0.2327 2.0 11.6
Tungsten hexafluoride 17.06 87.9 169.85 42.70 1.307 n.a. n.a.
Vinyl bromide 15.8 231.1 199.85 71.8 0.593 — 24.9
Vinyl chloride –13.37 365.2 158.85 56.700 0.3492 4.0 22.0
Vinyl methyl ether 5.5 421.3 163.85 46.7 0.3162 2.6 39.0
Xenon –108.12 96.1 16.59 58.404 1.1126 n.a. n.a.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name Chemical
formula
Molecular
weight
g/mol
Liquid state
Density
(at b.p. 1 atm)
lb/ft3
Density
(70 °F)
lb/ft3
Vapor
pressure
(70 °F) psi
Specific
heat (70 °F)
BTU • lb-1 • °F-1
Acetylene C2H2 26.038 38.539 24.673 646.21
Air, synthetic 28.96 — — — —
Ammonia NH3 17.031 42.500 37.926 128.51 1.150
Argon Ar 39.948 87.158 73.351
Arsine AsH3 77.945 101.074 83.396 219.32
Boron trichloride BCl3 117.17 83.934 82.819 19.91
Boron trifluoride BF3 67.806 98.024 89.022 — —
1,3-Butadiene C4H6 54.092 40.591 38.686 36.07 0.541
n-Butane C4H10 58.123 1,285.0 36.053 31.29 0.577
iso-Butane C4H10 58.123 37.105 34.780 45.81 0.576
1-Butene C4H8 56.107 39.051 37.017 38.58 0.541
cis-2-Butene C4H8 56.107 40.018 38.794 27.26 0.540
iso-Butene C4H8 56.107 39.132 37.064 39.59 0.552
trans-2-Butene C4H8 56.107 39.138 37.706 29.94 —
Carbon dioxide CO2 44.01 73.636 47.583 853.66
Carbon monoxide CO 28.01 49.274 40.831
Carbonyl sulfide COS 60.076 73.405 62.658 164.96 0.328
Chlorine Cl2 70.905 97.437 87.990 101.64
Cyanogen chloride CNCl 61.47 74.653 73.667 20.41 0.360
Cyclopropane C3H6 42.081 43.591 39.011 94.11
Deuterium D2 4.032 10.010 62.179
Diborane B2H6 27.67 26.745 82.819
Dichlorosilane SiH2Cl2 101.01 74.934 73.351 22.90 0.310
Dimethylamine (CH3)2NH 45.084 41.814 40.868 25.47
Dimethyl ether C2H6O 46.069 45.506 41.300 76.35
2,2-Dimethylpropane C5H12 2.59 37.647 21.93
Ethane C2H6 30.07 33.974 20.844 559.92
Ethene C2H4 28.054 35.539 20.844
Ethylene oxide C2H4O 44.053 56.534 54.189 22.13 0.477
Ethylamine C2H5NH2 45.084 55.055 42.541 17.45
Ethyl chloride C2H5Cl 64.514 42.843
Fluorine F2 37.997 93.907 62.179
Helium He 4.003 7.734 73.351
Hydrogen H2 2.016 4.397 76.162
Hydrogen bromide HBr 80.912 134.23 109.30 324.57 0.180
Hydrogen chloride HCl 36.461 74.428 51.028 625.37
Hydrogen fluoride HF 20.006 59.577 59.381 15.48
Hydrogen sulphide H2S 34.082 58.817 49.070 274.52
Krypton Kr 83.8 150.85 73.351
Methane CH4 16.043 26.452 83.442
Methylamine CH3NH2 31.057 43.323 41.218 44.63
Methyl bromide CH3Br 94.939 107.26 104.41 27.76
Methyl chloride CH3Cl 50.487 62.827 57.494 74.28 0.381
Methyl mercaptan CH3SH 48.109 55.355 54.150 25.67
Neon Ne 20.18 75.089 73.351
Nitric oxide NO 30.006 79.886 57.943
Nitrogen N2 28.014 50.384 194.64
Nitrogen dioxide NO2 46.006 90.626 90.668 14.66
Nitrogen trifluoride NF3 71.002 96.053 49.070
Nitrous oxide N2O 44.013 76.250 48.457 761.88
Physical data.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name Chemical
formula
Molecular
weight
g/mol
Liquid state
Density
(at b.p. 1 atm)
lb/ft3
Density
(70 °F)
lb/ft3
Vapor
pressure
(70 °F) psi
Specific
heat (70 °F)
BTU • lb-1 • °F-1
Octafluoropropane C3F8 188.02 100.09 83.586 115.05
Oxygen O2 31.999 71.229 62.179
Phosgene COCl2 98.916 87.452 85.639 24.00
Phosphine PH3 33.998 46.386 31.441 522.11
Propadiene C3H4 40.065 41.352 36.539 94.72
Propane C3H8 44.097 36.363 31.175 125.24 0.630
Propene C3H6 42.081 38.065 31.792 152.86 0.580
Propyne C3H4 40.065 41.920 38.241 74.09
R 11 Trichlorofluoromethane CFCl3 137.37 92.279 92.759 13.50 0.117
R 12 Dichlorodifluoromethane CF2Cl2 120.91 92.672 82.478 84.23 0.231
R 13 Chlorotrifluoromethane CF3Cl 104.46 94.986 56.927 474.18
R 13 b1 Bromotrifluoromethane CF3Br 148.91 124.29 97.681 213.69 0.206
R 14 Tetrafluoromethane CF4 88.005 100.21 56.927
R 21 Dichlorofluoromethane CHFCl2 102.92 87.676 85.949 23.00 0.251
R 22 Chlorodifluoromethane CHF2Cl 86.468 88.082 75.430 134.12 0.294
R 23 Trifluoromethane CHF3 70.014 90.527 49.324 625.58
R 114 1,2-Dichlorotetrafluorethane C2Cl2F4 170.92 94.706 91.599 27.43 0.155
R 115 Chloropentafluoroethane C2ClF5 154.47 96.352 81.543 119.53
R 116 Hexafluoroethane C2F6 138.01 99.664 81.543
R 134a Tetraflouroethane C2H2F4 102.03 85.761 76.162 85.69 0.340
R 142b 1-Chloro-1,1-difluoroethane C2H3ClF2 100.5 74.859 69.809 43.59 0.307
R 152a 1,1-Difluoroethane C2H4F2 66.051 63.251 56.656 77.60 0.391
Silane SiH4 32.117 36.338 31.441
Silicon tetrafluoride SiF4 104.08 — — — —
Sulphur dioxide SO2 64.065 86.004 50.67
Sulphur hexafluoride SF6 146.06 85.116 321.70
Trimethylamine (CH3)3N 59.111 39.548 27.52 0.553
Tungsten hexafluoride WF6 297.84 3.430 — 1.10 —
Vinyl bromide C2H3Br 106.95 94.220 17.74
Vinyl chloride C2H3Cl 62.499 56.785 51.26 0.324
Vinyl methyl ether C3H6O 58.08 46.780 26.27
Xenon Xe 131.29 73.351
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name Rel. spec. wgt,
air = 1
(59 °F, 14.5 psi)
Density
(70 °F)
lb/ft3
Gaseous state
Specific heat
(70 °F)
BTU • lb-1 • °F-1
Thermal
conductivity
BTU • h-1 • ft-1 • °F-1
Solubility
in water
ft3/lb (at °F)
Acetylene 0.91 0.068 0.401 0.0121 0.0160 (68 °F)
Air, synthetic 1.0 0.075 0.239 0.0003 (68 °F)
Ammonia 0.59 0.044 0.497 0.0141 11.0947 (68 °F)
Argon 1.38 0.103 0.124 0.0107 0.0005 (68 °F)
Arsine 2.73 0.204 0.117 0.0074 0.0032 (68 °F)
Boron trichloride 4.19 0.315 0.127 0.0051
Boron trifluoride 2.35 0.176 0.177 0.0094
1,3-Butadiene 1.94 0.144 0.352 0.0088 0.0037 (68 °F)
n-Butane 2.09 0.155 0.400 0.0092 0.0005 (68 °F)
iso-Butane 2.08 0.155 0.392 0.0093 0.0005 (68 °F)
1-Butene 2.01 0.149 0.361 0.0085 —
cis-2-Butene 2.00 0.150 0.333 0.0076 —
iso-Butene 2.01 0.149 0.376 0.0095 —
trans-2-Butene 2.00 0.150 0.371 0.0081 —
Carbon dioxide 1.53 0.114 0.201 0.0093 0.0136 (68 °F)
Carbon monoxide 0.97 0.072 0.248 0.0143 0.0004 (68 °F)
Carbonyl sulfide 2.11 0.157 0.164 0.0077 —
Chlorine 2.49 0.186 0.114 0.0051 0.0369 (68 °F)
Cyanogen chloride 2.18 0.163 0.176 0.0053 —
Cyclopropane 1.48 0.111 0.311 0.0094 —
Deuterium 0.14 0.010 1.723 0.0791 —
Diborane 0.97 0.072 0.494 0.0137 —
Dichlorosilane 3.60 0.217 0.145 0.0058
Dimethylamine 1.60 0.120 0.366 0.0094 1.9079 (140 °F)
Dimethyl ether 1.63 0.121 0.343 0.0094 —
2,2-Dimethylpropane 2.59 0.195 0.394 0.0084 —
Ethane 1.05 0.078 0.418 0.0119 0.0008 (68 °F)
Ethene 0.98 0.073 0.362 0.0117 0.0019 (68 °F)
Ethylene oxide 1.55 0.117 0.257 0.0072 —
Ethylamine 1.61 0.122 0.379 0.0096
Ethyl chloride 2.29 0.0319 (68 °F)
Fluorine 1.31 0.098 0.196 0.0148 —
Helium 0.14 0.010 1.240 0.0882 0.0001 (68 °F)
Hydrogen 0.07 0.005 3.406 0.0983 0.0003 (68 °F)
Hydrogen bromide 2.82 0.211 0.086 0.0050 7.4873 (77 °F)
Hydrogen chloride 1.27 0.095 0.191 0.0083 7.0545 (68 °F)
Hydrogen fluoride 0.71 0.053 0.348 — —
Hydrogen sulphide 1.19 0.089 0.239 0.0082 0.0401 (68 °F)
Krypton 2.90 0.217 0.059 0.0054 0.0010 (68 °F)
Methane 0.55 0.042 0.529 0.0191 0.0005 (68 °F)
Methylamine 1.10 0.082 0.389 0.0124 12.1369 (77 °F)
Methyl bromide 3.34 0.251 0.106 0.0042 —
Methyl chloride 1.78 0.133 0.191 0.0060 0.0545 (32 °F)
Methyl mercaptan 1.70 0.127 0.248 0.0076 0.1796 (59 °F)
Neon 0.70 0.052 0.246 0.0281 0.0002 (68 °F)
Nitric oxide 1.04 0.078 0.239 0.0145 0.0007 (68 °F)
Nitrogen 0.97 0.072 0.248 0.0144 0.0002 (68 °F)
Nitrogen dioxide 2.75 0.121 0.195
Nitrogen trifluoride 2.46 0.184 0.178 0.0122 —
Nitrous oxide 1.53 0.114 0.209 0.0099 0.0098 (68 °F)
Physical data.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name Rel. spec. wgt,
air = 1
(59 °F, 14.5 psi)
Density
(70 °F)
lb/ft3
Gaseous state
Specific heat
(70 °F)
BTU • lb-1 • °F-1
Thermal
conductivity
BTU • h-1 • ft-1 • °F-1
Solubility
in water
ft3/lb (at °F)
Octafluoropropane 6.53 0.498 0.186 0.0066 —
Oxygen 1.11 0.083 0.219 0.0150 0.0005 (68 °F)
Phosgene 3.50 0.263 0.139 0.0049 —
Phosphine 1.18 0.089 0.260 0.0121 0.0186 (75 °F)
Propadiene 1.41 0.105 0.355 —
Propane 1.56 0.116 0.399 0.0104 0.0006 (68 °F)
Propene 1.48 0.111 0.364 0.0099 0.0029 (68 °F)
Propyne 1.42 0.106 0.359 0.0091 —
R 11 Trichlorofluoromethane 4.92 0.135 0.0045 0.0029 (77 °F)
R 12 Dichlorodifluoromethane 4.29 0.319 0.142 0.0054 0.0008 (77 °F)
R 13 Chlorotrifluoromethane 3.65 0.273 0.152 0.0069 0.0003 (77 °F)
R 13 b1 Bromotrifluoromethane 5.23 0.391 0.110 0.0056 0.0001 (77 °F))
R 14 Tetrafluoromethane 3.05 0.228 0.165 0.0085 0.0001 (77 °F)
R 21 Dichlorofluoromethane 3.65 0.274 0.140 0.0048 0.0332 (77 °F)
R 22 Chlorodifluoromethane 3.04 0.227 0.156 0.0060 0.0124 (77 °F)
R 23 Trifluoromethane 2.44 0.182 0.174 0.0069 0.0050 (77 °F)
R 114 1,2-Dichlorotetrafluorethane 6.12 0.459 0.162 0.0063 0.0003 (77 °F)
R 115 Chloropentafluoroethane 5.48 0.408 0.166 0.0071 0.0001 (77 °F)
R 116 Hexafluoroethane 4.84 0.361 0.183 0.0197 —
R 134a Tetraflouroethane 3.53 0.270 0.200 0.0074 —
R 142b 1-Chloro-1,1-difluoroethane 3.59 0.267 0.194 0.0066 —
R 152a 1,1-Difluoroethane 2.34 0.174 0.243 0.0066 —
Silane 1.12 1.115 0.083 0.316
Silicon tetrafluoride 3.61 0.271 0.168 — —
Sulphur dioxide 2.26 0.169 0.148 0.0054 0.6125 (68 °F)
Sulphur hexafluoride 5.12 0.382 0.157 0.0076 0.0001 (77 °F)
Trimethylamine 2.10 0.158 0.367 0.0086 —
Tungsten hexafluoride 10.60 — — —
Vinyl bromide 3.72 0.284 0.123 0.0051 —
Vinyl chloride 2.21 0.165 0.204 0.0068 —
Vinyl methyl ether 2.03 0.155 0.0094 —
Xenon 4.56 0.341 0.038 0.0032 0.0019 (68 °F)
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name
Boiling point (14.5 psi) Critical point Flammability in air
Temperature
°F
Heat of
vaporization
70 °F BTU/lb
Temperature
°F
Pressure
psi(a)
Density
lb/ft3
Lower
limit
% volume
Upper
limit
% volume
Acetylene –119.45 126.391 95.33 890.42 14.39 2.2 85.0
Air, synthetic –317.81 –221.24 547.38 19.54 — —
Ammonia –28.15 508.275 270.52 1,635.77 14.67 15.0 27.0
Argon –302.55 –188.10 710.43 33.44 n.a. n.a.
Arsine –80.44 70.307 211.75 950.02 49.75 5.8 n.a.
Boron trichloride 54.52 85.871 353.86 561.40 49.31 n.a. n.a.
Boron trifluoride –147.62 9.97 723.06 34.24 n.a. n.a.
1,3-Butadiene 24.08 167.210 306.02 628.01 15.29 2.0 12.0
n-Butane 31.12 156.668 305.67 550.71 14.23 1.8 8.4
iso-Butane 10.92 143.318 275.00 529.11 13.81 1.8 8.4
1-Butene 20.77 159.146 295.61 583.01 14.60 1.6 10.0
cis-2-Butene 38.72 171.736 324.39 610.01 14.97 1.7 9.7
iso-Butene 19.62 157.215 292.57 580.02 14.66 1.8 9.6
trans-2-Butene 33.60 166.781 311.88 595.02 14.71 1.7 9.7
Carbon dioxide –69.81 61.891 87.89 1,070.62 29.23 n.a. n.a.
Carbon monoxide –312.59 –220.39 507.47 18.78 12.5 74.0
Carbonyl sulfide –58.25 107.332 222.19 920.87 27.76 12.0 29.0
Chlorine –29.23 108.285 291.22 1,118.38 35.77 n.a. n.a.
Cyanogen chloride 55.20 183.806 348.55 868.80 23.54
Cyclopropane –26.98 176.402 256.59 808.59 16.14
Deuterium –417.07 –390.62 241.01 4.18 5.0 75.0
Diborane –134.48 61.99 587.85 9.98 0.9 98.0
Dichlorosilane 46.96 104.154 348.55 642.53 27.66 4.1 98.8
Dimethylamine 44.40 244.023 328.12 770.08 15.05 2.8 14.4
Dimethyl ether –12.69 177.401 260.53 778.90 16.92 3.4 27.0
2,2-Dimethylpropane 49.12 131.442 1.4 7.5
Ethane –127.46 86.369 90.11 707.81 12.69 3.0 12.4
Ethene –154.60 48.60 729.82 13.57 3.1 32.0
Ethylene oxide 51.28 245.385 384.82 1043.44 19.60 3.0 100.0
Ethylamine 61.86 257.945 361.42 815.64 15.46
Ethyl chloride
Fluorine –306.74 –199.89 756.42 35.83 n.a. n.a.
Helium –452.05 –450.29 33.00 4.36 n.a. n.a.
Hydrogen –422.95 –399.93 190.44 1.96 4.0 74.5
Hydrogen bromide –88.04 69.029 194.02 1,240.36 50.38 n.a. n.a.
Hydrogen chloride –120.98 113.120 124.72 1,205.10 28.09 n.a. n.a.
Hydrogen fluoride 67.16 370.42 940.56 18.10 n.a. n.a.
Hydrogen sulphide –76.61 182.314 212.70 1,299.99 21.60 4.0 44.0
Krypton –244.01 –82.82 798.02 57.36 n.a. n.a.
Methane –258.66 –116.61 667.81 10.09 5.0 15.0
Methylamine 20.63 335.510 314.44 1,081.64 12.59 4.9 20.7
Methyl bromide 38.43 106.708 380.95 1,160.33 37.99 10.0 16.0
Methyl chloride –11.58 164.406 289.60 968.77 22.67 10.7 17.4
Methyl mercaptan 42.75 212.839 386.26 1,049.31 20.71 4.0 22.0
Neon –410.89 –379.73 384.79 30.21 n.a. n.a.
Nitric oxide –241.17 –135.38 940.56 32.46 n.a. n.a.
Nitrogen –320.42 –232.67 492.33 19.41 n.a. n.a.
Nitrogen dioxide 69.55 316.78 1,469.70 34.82 n.a. n.a.
Nitrogen trifluoride –200.29 –38.72 657.02 37.33 n.a. n.a.
Nitrous oxide –127.24 70.666 97.58 1,050.78 28.22 n.a. n.a.
Physical data.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name
Boiling point (14.5 psi) Critical point Flammability in air
Temperature
°F
Heat of
vaporization
70 °F BTU/lb
Temperature
°F
Pressure
psi(a)
Density
lb/ft3
Lower
limit
% volume
Upper
limit
% volume
Octafluoropropane –34.13 33.672 161.44 388.72 39.26 n.a. n.a.
Oxygen –297.34 –181.41 731.44 27.22 n.a. n.a.
Phosgene 45.63 104.449 359.35 822.99 32.46 n.a. n.a.
Phosphine –125.91 116.744 124.90 947.92 18.73
Propadiene –30.08 186.405 248.02 793.37 15.44
Propane –43.65 146.960 206.03 616.31 13.57 2.2 9.5
Propene –53.82 147.470 198.38 676.62 13.94 2.0 10.5
Propyne –9.76 208.082 264.65 816.23 15.25 1.7 12.0
R 11 Trichlorofluoromethane 74.90 79.208 388.51 639.28 34.58
R 12 Dichlorodifluoromethane –21.60 61.154 233.26 598.28 34.78 n.a. n.a.
R 13 Chlorotrifluoromethane –114.52 24.064 83.88 572.33 36.17 n.a. n.a.
R 13 b1 Bromotrifluoromethane –72.18 35.406 152.62 576.09 46.48 n.a. n.a.
R 14 Tetrafluoromethane –198.49 –50.15 542.29 39.24 n.a. n.a.
R 21 Dichlorofluoromethane 48.04 100.250 353.19 751.86 32.78 n.a. n.a.
R 22 Chlorodifluoromethane –41.47 79.594 205.09 721.00 32.52 n.a. n.a.
R 23 Trifluoromethane –115.87 33.395 78.35 701.45 32.79 n.a. n.a.
R 114 1,2-Dichlorotetrafluorethane 38.81 55.491 294.28 473.23 36.33 n.a. n.a.
R 115 Chloropentafluoroethane –38.38 41.375 176.02 457.94 38.27 n.a. n.a.
R 116 Hexafluoroethane –108.74 67.39 432.08 38.46 n.a. n.a.
R 134a Tetraflouroethane –14.78 78.666 214.09 589.45 31.69 n.a. n.a.
R 142b 1-Chloro-1,1-difluoroethane 14.00 87.570 278.71 598.13 27.16 9.0 15.0
R 152a 1,1-Difluoroethane –14.42 121.954 236.23 652.51 22.78 4.0 18.0
Silane –169.85 25.81 702.48 15.11 1.0 100
Silicon tetrafluoride –139.25 6.55 539.35 39.38 n.a. n.a.
Sulphur dioxide 13.98 152.612 315.70 1,143.52 32.78 n.a. n.a.
Sulphur hexafluoride –83.00 28.302 113.99 545.35 45.93 n.a. n.a.
Trimethylamine 37.19 162.632 320.20 590.80 14.53 2.0 11.6
Tungsten hexafluoride n.a. n.a.
Vinyl bromide 60.46 98.433 391.75 1,041.39 33.38 — 24.9
Vinyl chloride 7.95 140.958 317.95 822.38 21.80 4.0 22.0
Vinyl methyl ether 41.92 174.163 326.95 677.34 17.27 2.6 39.0
Xenon –162.60 61.88 847.10 69.46 n.a. n.a.
HiQ® Specialty gas program.Equipment & gas distribution systems.
Conversion tables.
Dew point – Moisture
Dew point Moisture Dew point Moisture
°C °F vpm mg/m3 °C °F vpm mg/m3
–20.0 –4.0 1,030 790 –55.0 –67.0 20.6 15.7–21.0 –5.8 940 710 –56.0 –68.8 18.2 13.8–22.0 –7.6 860 640 –57.0 –70.6 15.9 11.1–23.0 –9.4 765 580 –58.0 –72.4 13.9 10.6–24.0 –11.2 697 527 –59.0 –74.2 12.1 9.2–25.0 –13.0 625 478 –60.0 –76.0 10.6 8.0–26.0 –14.8 553 430 –61.0 –77.8 9.2 7.0–27.0 –16.6 517 390 –62.0 –79.6 8.0 6.2–28.0 –18.4 467 352 –63.0 –81.4 6.98 5.3–29.0 –20.2 426 318 –64.0 –83.2 6.08 4.6–30.0 –22.0 380 288 –65.0 –85.0 5.28 4.0–31.0 –23.8 342 260 –66.0 –86.8 4.58 3.5–32.0 –25.6 309 232 –67.0 –88.6 3.96 3.0–33.0 –27.4 276 210 –68.0 –90.4 3.40 2.6–34.0 –29.2 249 188 –69.0 –92.2 2.94 2.2–35.0 –31.0 222 168 –70.0 –94.0 2.53 1.9–36.0 –32.8 200 151 –71.0 –95.8 2.17 1.7–37.0 –34.6 179 135 –72.0 –97.6 1.87 1.4–38.0 –36.4 162 122 –73.0 –99.4 1.61 1.2–39.0 –38.2 144 109 –74.0 –101.2 1.37 1.0–40.0 –40.0 128 97 –75.0 –103.0 1.17 0.9–41.0 –41.8 114 86 –76.0 –104.8 1.01 0.8–42.0 –43.6 102 77 –77.0 –106.6 0.86 0.7–43.0 –45.4 90 68.5 –78.0 –108.4 0.73 0.6–44.0 –47.2 80 61.0 –79.0 –110.2 0.62 0.5–45.0 –49.0 71.9 54.1 –80.0 –112.0 0.52 0.4–46.0 –50.8 63.5 48.0 –81.0 –113.8 0.50 0.34–47.0 –52.6 56.2 42.5 –82.0 –115.6 0.38 0.29–48.0 –54.4 49.9 37.8 –83.0 –117.4 0.32 0.24–49.0 –56.2 44.0 33.3 –84.0 –119.2 0.26 0.19–50.0 –58.0 39.0 29.5 –85.0 –121.0 0.22 0.17–51.0 –59.8 34.2 26.0 –86.0 –122.8 0.19 0.14–52.0 –61.6 30.4 23.0 –87.0 –124.6 0.16 0.12–53.0 –63.4 26.7 20.3 –88.0 –126.4 0.11 0.10–54.0 –65.2 23.4 17.8 –89.0 –128.2 0.11 0.08
HiQ® Specialty gas program.Equipment & gas distribution systems.
Pressure units (1 bar = 14.5 psi)
psi bar kPa1 0.07 72 0.14 145 0.34 3410 0.69 6920 1.38 13830 2.07 20750 3.45 345100 6.89 690300 20.68 2,068500 34.47 3,447
1,000 68.95 6,8952,000 137.90 13,7904,000 275.79 27,579
bar psi kPa0.1 1.45 100.5 7.25 501 14.50 1002 29.00 2005 72.52 50010 145.03 1,00020 290.06 2,00050 725.15 5,000100 1,450.30 10,000200 2,900.60 20,000300 4,350.90 30,000400 5,801.20 40,000
Tightness – Leakage
cm3/sec. (helium) time for leakage of 1 cm3 helium at 1 atm
1 × 10–1 10.0 seconds1 × 10–2 1.5 minutes1 × 10–3 15.0 minutes1 × 10–4 3 hours1 × 10–5 30 hours1 × 10–6 12 days1 × 10–7 4 months1 × 10–8 3 years1 × 10–9 30 years1 × 10–10 300 years1 × 10–11 3,000 years1 × 10–12 30,000 years
Gas – Mass – Liquid
1 m3 m3 gas(+15 °C,1013 mbar)
kg litre liquid(boiling point,1013 mbar)
Acetylene 1.0 1.11 —Argon 1.0 1.69 1.21Helium 1.0 0.169 1.35Hydrogen 1.0 0.085 1.20Carbon dioxide 1.0 1.87 2.29Nitrogen 1.0 1.19 1.47Oxygen 1.0 1.36 1.19Propane 1.0 1.90 3.28
1 kgAcetylene 0.902 1.0 —Argon 0.591 1.0 0.717Helium 5.91 1.0 7.98Hydrogen 11.74 1.0 14.10Carbon dioxide 0.534 1.0 1.22Nitrogen 0.843 1.0 1.24Oxygen 0.738 1.0 0.876Propane 0.525 1.0 1.72
1 litre liquidAcetylene — — —Argon 0.825 1.39 1.0Helium 0.741 0.125 1.0Hydrogen 0.832 0.071 1.0Carbon dioxide 0.436 0.818 1.0Nitrogen 0.681 0.807 1.0Oxygen 0.842 1.14 1.0Propane 0.305 0.582 1.0
ppm (part per million) – percentage
1 ppm = 0.0001%10 ppm = 0.001%100 ppm = 0.01%
1,000 ppm = 0.1%10,000 ppm = 1.0%100,000 ppm = 10.0%
1,000,000 ppm = 100.0%
HiQ® Specialty gas program.Equipment & gas distribution systems.
Material compatibility.
Gas name Chemical
formula
Acetylene C2H22
Air, synthetic
Ammonia NH31
Argon Ar
Arsine AsH3
Boron trichloride BCl3Boron trifluoride BF3
1 1 1 1
1,3-Butadiene C4H6
n-Butane C4H10
iso-Butane C4H10
1-Butene C4H8
cis-2-Butene C4H8
iso-Butene C4H8
trans-2-Butene C4H8
Carbon dioxide CO2
Carbon monoxide CO 4
Carbonyl sulfide COS 1 1 1 1 1 1
Chlorine Cl2Chlorine trifluoride ClF3
12 10 12 10 10
Cyanogen CNCN
Cyanogen chloride CNCl
Cyclopropane C3H6
Deuterium D2
Diborane B2H6
Dichlorosilane SiH2Cl210 7 11
Dimethylamine (CH3)2NH
Dimethyl ether C2H6O
2,2-Dimethylpropane C5H12
Ethane C2H6
Ethene C2H4
Ethylene oxide C2H4O
Ethylamine C2H5NH2
Ethyl chloride C2H5Cl1 1 1 1 1 1
Fluorine F2Germane GeH4
Helium He
Hydrogen H2
Hydrogen bromide HBr 1 1 5 1
Hydrogen chloride HCl 1 1 10 8 7 1 11
Hydrogen fluoride HF 3 9 10 3 7 11
Hydrogen selenide HSe
Hydrogen sulfide H2S1 1 10 1 11
Krypton Kr
Methane CH4
Methylamine CH3NH2
Methyl bromide CH3Br6 1 1 1
Methyl chloride CH3Cl6 1 1 1
Methyl fluoride CH3F
Methyl mercaptan CH3SH
Neon Ne
Aluminum
Buna®
N
Brass
Butylrubber
Carbon
steel
Copper
Kel-F®
Monel
®
Neoprene®
Nylon
®
Polyethene
PVC
Stainlesssteel
Teflon®
Viton®
HiQ® Specialty gas program.Equipment & gas distribution systems.
Gas name Chemical
formula
Nitric oxide NO 1 1 1 1
Nitrogen N2
Nitrogen dioxide NO21 1
Nitrogen trifluoride NF310 12 10 10
Nitrous oxide N2O
Octafluoropropane C3F8Oxygen O2
Phosgene COCl21 1 7 1
Phosphine PH3
Propane C3H8
Propene C3H6
Propyne C3H4
R 11 Trichlorofluoromethane CFCl3R 12 Dichlorodifluoromethane CF2Cl2R 13 Chlorotrifluoromethane CF3Cl
R 13 b1 Bromotrifluoromethane CF3Br
R 14 Tetrafluoromethane CF4R 21 Dichlorofluoromethane CHFCl2R 22 Chlorodifluoromethane CHF2Cl
R 23 Trifluoromethane CHF3R 114 1,2-Dichlorotetrafluorethane C2Cl2F4R 115 Chloropentafluoroethane C2ClF5
R 116 Hexafluoroethane C2F6
R 142b 1-Chloro-1,1-difluoroethane C2H3ClF2R 152a 1,1-Difluoroethane C2H4F2
7
Silane SiH4
Silicon tetrafluoride SiF49 1 10 3 7 11
Sulphur dioxide SO21 1 1 10 1 1 11
Sulphur hexafluoride SF6Trimethylamine (CH3)3N
Tungsten hexafluoride WF612 10 12 10 10
Vinyl bromide C2H3Br1
Vinyl chloride C2H3Cl1 1 1 1 1 1
Vinyl methyl ether C3H6O
Xenon Xe
Aluminum
Buna®
N
Brass
Butylrubber
Carbon
steel
Copper
Kel-F®
Monel
®
Neoprene®
Nylon
®
Polyethene
PVC
Stainlesssteel
Teflon®
Viton®
Legend
Good
Fair
Avoid
Data missing
1 Avoid in presence of moisture
2 <65% Cu
3 Avoid in presence of oxygen
4 Up to 100 bar (1,450 psi)
5 In absence of oxygen
6 Possible forming of spontaneously
flammable compounds
7 <50 °C (120 °F)
8 <100 °C (210 °F)
9 <150 °C (300 °F)
10 <180 °C (360 °F)
11 <250 °C (480 °F)
12 <400 °C (750 °F)
AAccessories 217
centralized monitoring
systems 218
contact gauges 220
gas cylinder trolley 224
mounting bracket 222
pressure transducers 220
wall mounting bracket 224
ACCURA® cylinder
management system 232
acetylene 72, 238, 252
air, synthetic 72, 238, 252
AISI 316L 215
alarms 12, 151
aluminum 252
ammonia 72, 238, 252
analysis certificate 234
analysis service 233
application safety training 233
argon 72, 238, 252
arsine 72, 238, 252
ASTM A 269 215
automatic gas supply 232
BBASELINE™ 6
C 106/1 102
C 106/2 106
C 106X/1 104
C 106X/2 108
R 104/1 126
boron trichloride 72, 238, 252
boron trifluoride 72, 238, 252
brass 252
Buna® N 252
1,3-butadiene 72, 238, 252
n-butane 72, 238, 252
iso-butane 72, 238, 252
1-butene 72, 238, 252
cis-2-butene 72, 238, 252
iso-butene 72, 238, 252
trans-2-butene 72, 238, 252
butyl rubber 252
Ccarbon steel 252
carbon dioxide 72, 238, 252
carbon monoxide 72, 238, 252
carbonyl sulfide 72, 238, 252
central gas supply 9
certificate of conformity 235
chlorine 72, 238, 252
chlorine trifluoride 72, 252
CleanLine™ 6
B 25 bench/suspended
mounting 86
I 25 inset design 82
P 25 panel mounting 80
W 25 wall mounting 84
compatibility 252
Components 111
R 104/1 126
R 12 122
R 12hv/1 124
R 200/1 112
R 200/2 116
R 200/F 114
R 200hv/2 118
R 40 120
R 480/1 144
V 1315 134
V 200 132
V 40 128
V 50 130
connections 7, 209, 228
contact gauges 220
containers 165
contents 3
conversion tables 250
copper 11, 252
cyanogen 72, 252
cyanogen chloride 72, 238, 252
cyclopropane 72, 238, 252
cylinder bundles 203
Cylinder connections
ABNT 210
AFNOR 210
BS 341 211
CGA 211
DIN 477 212
IRAM 2539 212
ISO 5145 212
MIE 213
NEN 3268 213
UNI 213
cylinder management 232
Cylinder regulators
BASELINE™
C 106/1 102
C 106/2 106
C 106X/1 104
C 106X/2 108
HiQ® REDLINE
C 12hv/1 70
C 200/1 64
C 200/2 66
C 200hv/2 68
Special cylinder regulators
C 421/1 146
C 450/1 mini 148
C 490/1 142
cylinder trolley 224
cylinder types 203
cylinder valves 209
Ddetection 12
deuterium 72, 238, 252
dew point 250
diaphragm valve 209
diborane 72, 238, 252
dichlorosilane 72, 238, 252
dimethylamine 72, 238, 252
dimethyl ether 72, 238, 252
2,2-dimethylpropane 72, 238, 252
documentation 13
EeBusiness 231
ECOCYL® RSH 198
ECOCYL® VAH/VSH 200
EN 10216-5 215
EPA protocol 235
ethane 72, 238, 252
ethene 72, 238, 252
ethylamine 72, 238, 252
ethyl chloride 72, 238, 252
ethylene oxide 72, 238, 252
Ffittings 209, 215
Gyrolok® 215
Parker A-LOK® 215
Swagelok® 215
flow meter 98
fluorine 72, 238, 252
Ggas cabinets 12, 152
gas detector 165
Gas panels
double gas panel
D 204 38
purge gas panels
2-valve purge gas panel 154
HiQ® Specialty gas program.Equipment & gas distribution systems.
Index.
Index.
3-valve process gas panel 156
5-valve process gas panel 158
semi-automatic gas panels
A 208 44
A 209 48
single gas panels
S 200 16
S 201 20
S 202 26
S 203 32
gauge pressure 6
general symbols 6
germane 72, 252
gravimetrical production 235
Hhelium 74, 238, 252
high purity 11
HiQ® Analysis certificate 234
HiQ® codes 7
HiQ® Gas Supply System
Installations 227
HiQ® REDLINE 6
central gas supply 9
components 111
cylinder regulators 63
gas panels 15
points of use 53
the right choice 72
HOGEN® HGS, hydrogen
generator 176
hydrogen 74, 238, 252
hydrogen bromide 74, 238, 252
hydrogen chloride 74, 238, 252
hydrogen fluoride 74, 238, 252
hydrogen selenide 252
hydrogen sulfide 74, 252
hydrogen sulphide 238
Iinlet connections 209
installations - checklist 228
integrated flow valve 197
integrated regulator 197
KKel-F® 252
krypton 74, 238, 252
Lleakage 251
Mmaterial compatibility 252
methane 74, 238, 252
methylamine 74, 238, 252
methyl bromide 74, 238, 252
methyl chloride 74, 238, 252
methyl fluoride 74, 252
methyl mercaptan 74, 238, 252
Monel® 252
monitoring systems 218
mounting bracket (for
BASELINE R 104/1) 222
Nnatural gas 74
neon 74, 238, 252
Neoprene® 252
NIST 235
nitric oxide 74, 238, 253
nitrogen 74, 238, 253
nitrogen dioxide 74, 238, 253
nitrogen trifluoride 74, 238, 253
nitrous oxide 74, 238, 253
Nylon® 252
Ooctafluoropropane 74, 239, 253
on-line ordering 231
operating economy 10
operation monitor 160
origami 1
outlet connections 214
oxygen 74, 239, 253
Pphosgene 74, 239, 253
phosphine 74, 239, 253
physical data 237
pipe systems 12
Points of use
CleanLine™
B 25 bench/suspended
mounting 86
I 25 inset design 82
P 25 panel mounting 80
W 25 wall mounting 84
HiQ® REDLINE
B 40 bench design 56
I 40X inset design 60
L 40 fume cupboard design 58
W 40 wall design 54
Quick Connect
connection points 90
flow meter 98
outlets 94
regulator 96
polyethene 252
Portable gas solutions 197
ECOCYL® RSH 198
ECOCYL® VAH/VSH 200
preface 5
pressure transducers 220
pressure units 251
propadiene 239
propane 74, 239, 253
propene 74, 239, 253
propyne 74, 239, 253
purge time 11
PVC 252
QQuick Connect 6
connection points 90
flow meter 98
outlets 94
pressure regulator 96
RR 11, trichlorofluoro-
methane 74, 239, 253
R 12, dichlorodifluoro-
methane 74, 239, 253
R 13 b1, bromotrifluoro-
methane 74, 239, 253
R 13, chlorotrifluoro-
methane 74, 239, 253
R 14, tetrafluoro-
methane 74, 239, 253
R 21, dichlorofluoro-
methane 74, 239, 253
R 22, chlorodifluoro-
methane 74, 239, 253
R 23, trifluoromethane74, 239, 253
R 32, difluoromethane 76
R 114, 1,2-dichlorotetra-
fluorethane 76, 239, 253
R 115, chloropenta-
fluoroethane 76, 239, 253
R 116, hexafluoro-
ethane 76, 239, 253
R 134a, tetraflouroethane 239
R 142b, 1-chloro-1,1-
difluoroethane 76, 239, 253
R 152a, 1,1-difluoro-
ethane 76, 239, 253
reference material 234
returnable cylinders 203
roller conveyor 165
Ssafety 10
safety audits 233
Safety solutions 151
2-valve purge gas panel 154
3-valve process gas panel 156
5-valve process gas panel 158
containers 165
fully automatic 162
monitoring systems 218
operation monitor 160
standard cabinets 152
safety training 233
SECCURA™ automatic gas
supply 232
service agreement 10
Services 231
silane 76, 239, 253
silicon tetrafluoride 76, 239, 253
Single stage cylinder regulators
C 106/1 102
C 106X/1 104
C 12hv/1 70
C 200/1 64
C 421/1 146
C 450/1 mini 148
C 490/1 142
Special equipment
C 421/1 146
C 450/1 mini 148
C 490/1 142
IntelliSwitch™ 138
R 480/1 144
STABLEFLOW™ HCS 140
Specialty gas generators 171
hydrogen generation system,
HOGEN® HGS 176
hydrogen no-maintenance 172
hydrogen pure gas 174
nitrogen (BORA mini) 180
nitrogen (ELSD generator) 182
nitrogen LC/MS 0 188
HiQ® Specialty gas program.Equipment & gas distribution systems.
nitrogen LC/MS 4 186
nitrogen LC/MS Plus 184
nitrogen SIROCCO DS-PSA 178
Ultra Zero Air generator 190
Zero Air generator 192
specialty gas safety training 233
STABLEFLOW™ HCS 140
stainless steel 11, 252
standard purity 11
STP 6
sulphur dioxide 76, 239, 253
sulphur hexafluoride 76, 239, 253
system design 11
TTeflon® 252
tightness 251
timesaving tools 231
traceabilty 235
training 233
trimethylamine 76, 239, 253
trolley (for gas cylinders) 224
tubings 209, 215
tungsten hexafluoride 76, 239, 253
turnkey deliveries 10
Two stage cylinder regulators
C 106/2 106
C 106X/2 108
C 200/2 66
C 200hv/2 68
Vvinyl bromide 76, 239, 253
vinyl chloride 76, 239, 253
vinyl methyl ether 76, 239, 253
Viton® 252
Wwalkthroughs 233
wall mounting bracket 224
washer valve 209
web ordering 231
working environment 10
Xxenon 76, 239, 253
HiQ® Specialty gas program.Equipment & gas distribution systems.
Getting ahead through innovation.
With its innovative concepts, Linde Gas is playing a pioneering role in the global market. As a technology leader, it is our task
to constantly raise the bar. Traditionally driven by entrepreneurship, we are working steadily on new high-quality products
and innovative processes.
Linde Gas offers more. We create added value, clearly discernible competitive advantages, and greater profitability. Each
concept is tailored specifically to meet our customers’ requirements – offering standardized as well as customized solutions.
This applies to all industries and all companies regardless of their size.
If you want to keep pace with tomorrow’s competition, you need a partner by your side for whom top quality, process
optimization, and enhanced productivity are part of daily business. However, we define partnership not merely as being
there for you but being with you. After all, joint activities form the core of commercial success.
Linde Gas – ideas become solutions.
Linde AG
Linde Gas Division, Seitnerstrasse 70, DE-82049 Pullach, Germany
Phone +49.89.7446-0, Fax +49.89.7446-1230, www.linde-gas.com
15$/
15€
1234
5678
0507
–1.1xy