High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100...

16
A Responsible Enterprise High Quality Vehicle Headlight Tester & Emission Gas Analyzer Zhejiang University Mingquan Scien-Tech Co.,Ltd Tel./Fax:+86-571-87972473 E-mail:[email protected] www.zdmq.com

Transcript of High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100...

Page 1: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

A Responsible Enterprise

High Quality Vehicle Headlight Tester & Emission Gas Analyzer

Zhejiang University Mingquan

Scien-Tech Co.,Ltd

Tel./Fax:+86-571-87972473

E-mail:[email protected]

www.zdmq.com

Page 2: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

Introduction

2. Strategy

About Us

R&D Team and Awards

www.zdmq.com

Founded in Oct 2002,Mingquan combines its own

powerful R&D capacities with strong technical force of

Zhejiang University.

Design, manufacture and market high performance

vehicles Headlight Tester, exhaust gas analyzer, diesel

smoke meter/Opacimeter, engine RPM meter,OEM

products, and other automotive testing and garage

equipments since 1993.

R&D Team

In 2012, our R&D Team awarded the honor of "Zhejiang province High and New

Technology Research and Development Center".

Mingquan was honored as "Zhejiang Province High-tech Enterprise" in 2008 and 2011.

All the core technologies have completely independent intellectual property

rights ,Invention Patents and Utility Model Patents.

Awards& Workshops

Page 3: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

MQD-6A Full Automatic Headlight Tester

2. Strategy

1. Introduction

www.zdmq.com

High-speed DSP6000 image processing system ,quick to track the

headlamp automatically.

Dual CCD camera for accurate and reliable testing operation.

LED display,Powerful on-line adjusting function.

VGA,PAL,RS232 interface, and confidential communication protocol.

Runs fast,at average 40s,and only 25 seconds with dual-lamp test

synchronously.

Test all halogen, xenon, LED headlamps, RHD&LHD cars and trucks.

Suitable for vehicles inspection stations,auto manufacturer and

garages.

Technical Data

Center lens from the ground 350 ~ 1400mm, ±10mm

Luminous Intensity 0 to 120,000 cd, ≤ ±10%

Measurement RangeUp 0-400mm/10m Down 0-560mm/10m

Left 0-560mm/10m Right 0-560mm/10m

Accuracy ±32mm/10m

Power Supply AC220V ±10%,50Hz ±1Hz, 200W/37W

Operating Temperature -5℃ - +40℃

Net Weight 100kg

Dimension(W*H*D) 80*170*67cm

Package Dimension Wooden case: 100*70*180cm

Guide Rail Length:5m Weight:35KG

Test Distance 1m

Page 4: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

MQD-6B Full Automatic Headlight Tester

1. Introduction

High-speed DSP6000 image processing system,dual CCD cameras

and microcomputer inside,accurate control and reliable operation.

Powerful function of self-checking for fault, on-line adjusting

headlamps.

Work for all types of incandescent, halogen, xenon, LED headlamps,

RHD& LHD vehicles.

Run very fast at average 40s,only 20 seconds to finish the test with

dual lamps testing synchronously.

Equipped with Industrial PC and LED display, automatically indicates

the adjustment direction of the headlight.

Red warning light on when the tester working.

Suitable for Top vehicle inspection stations,auto manufacturer and

headlamp manufacturer.

Technical Data

Center lens from the ground 350mm ~ 1400mm, ≤ ±10mm

Luminous Intensity 0 to 120,000 cd, ≤ ±10%

Measurement RangeUp 400mm/10m Down 560mm/10m

Left 560mm/10m Right 560mm/10m

Accuracy ±32mm/10m

Power Supply AC220V ±10%, 50Hz ±1Hz,200W/37W

Operating Temperature -10℃ - +40℃

Net Weight 100kg

Dimension(W*H*D) 80*170*67cm

Package Dimension Wooden case:100*70*180cm

Guide Rail Length:5m Weight:35KG

Test Distance 80cm to 120cm

www.zdmq.com

Page 5: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

QDC-3(G) Manual Headlight Tester

www.zdmq.com

-A counter-weight in the positioned stand allows an easy up-down

movement of the optical box

-Test and adjust high beam, low beam, fog light, and daytime running

lamps.

-Rotatable laser alignment makes it easy to align headlamps

-CCD camera, Big LCD display with smart touch screen.USB mouse

and keyboard are acceptable.

-Test halogen lamps, xenon lamps and LED lamps.

-Test SAE, ECE, and Japanese standard beams, LHD and RHD

vehicles.

-Support handheld devices such as mobile client terminal

-Multi-communication of a serial port, Ethernet, Bluetooth and Wifi.

-Large-capacity lithium battery to ensure the life span of more than 8

hours

-Software to support multi-language switching

-Suitable for vehicle inspection station, garages and auto service

shops.

Technical Data

Center lens from the ground 250mm - 1350mm

Luminous Intensity 0 to 120,000 cd, ±5%

Measurement Range

(except fog light)

Up 0 -600mm/10m Down 0-600mm/10m

Left 0-1000mm/10m Right 0-1000mm/10m

Measurement Range

(fog light)Up 0-600mm/10m Down 0-600mm/10m

Accuracy ± 10mm/10m (±4’)

Power Supply DC12.6V,10.4AH

Operating Temperature -15℃ - +40℃

Net Weight 60kg

Dimension(W*H*D) 70*182*62.5cm

Test Distance 10cm to 100cm

Page 6: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

QDC-3(B) Manual Headlight Tester

2. Strategy

1. Introduction

European styled appearance, CCD camera,DSP 5000 processing &

UPSD single-chip system.

A counter-weight in the positioned stand allows an easy up-down

movement of the optical box.

Battery-operated in low power consumption mode.

Test incandescent, halogen and xenon headlamps.

RS232 interface, LCD display

Easy operation,accurate measurement,500 test records storages.

Optional wireless communication and micro printer.

Suitable for garage and auto service shops.

Technical Data

Center lens from the ground 250mm ~ 1400mm, ±10mm

Luminous Intensity 0 to 120,000 cd, ±10%

Measurement RangeUp 350mm/10m Down 525mm/10m

Left 525mm/10m Right 525mm/10m

Accuracy ±35mm/10m

Power Supply AC220V ±10%,50±1Hz or DC12V,25W/5W

Operating Temperature -5℃ - +40℃

Net Weight 60kg

Dimension(W*H*D) 70*181*61.6cm

Package DimensionCtn#1:72*56*64cm Ctn#2:72*58*33cm

ctn#3:187*41*33cm

Test Distance 0.5m

www.zdmq.com

Page 7: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

QDC-3(C) Manual Headlight Tester

www.zdmq.com

European styled appearance,Laser assited light tracking

system

A counter-weight in the positioned stand allows an easy up-

down movement of the optical box

Battery-operated in low power consumption mode.

Test incandescent, halogen and xenon headlamps.

RS-232 interface,LCD display

Light and flexible,easy operation,easy to move and maintain.

Optional wireless communication and micro printer.

Suitable for mobile testing station, garages and auto service

shops.

Technical Data

Center lens from the ground 300mm ~ 1300mm

Luminous Intensity 0 to 120,000 cd, ±10%

Measurement RangeUp 0-350mm/10m Down 0-525mm/10m

Left 0-525mm/10m Right 0-525mm/10m

Accuracy ±35mm/10m

Power Supply AC220V ±10% 50Hz ±1Hz,DC12V,15W

Operating Temperature -5℃ - +40℃

Net Weight 40kg

Dimension(W*H*D) 68*158*57cm

Package Dimension Ctn#1:75*56*46cm Ctn#2:161*37*24cm

Test Distance 0.5m

Page 8: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

MQ-550 Automotive Exhaust Gas Analyzer

2. Strategy

1. Introduction

Automatic measure the concentration of HC,CO,CO2,O2 and NOx.

NDIR gas sensor,HORIBA bench from Japan,OIML class 1 accuracy.

LCD display

Automatic zero resetting

Automatic calculation and display of Air-Fuel Ratio

Equipped with RPM and oil temperature measure interface.

With functions of License Plate Number Input and time display

500 sets of data storage and intelligent review

RS232 interface,easy operation, accurate measurement and reliable

performance

Small,light and portable to carry with.

Optional micro printer and RPM meter.

Ideal for idle & two-speed idle emission test.

Technical Data

ITEM Method Resolution Measurement RangeAbsolute

Accuracy

Relative Accuracy

HC NDIR 1ppm0-5000ppm ±12ppm ±5%

5001-9999ppm ±10%

CO NDIR 0.01%0.00-10% ±0.06% ±5%

10.01-16.00% ±10%

CO2 NDIR 0.1% 0.0-18.0% ±0.5% ±5%

NO (5 gas

analyzer)EC 1ppm

0-4000ppm ±25ppm ±4%

4001-5000ppm ±8%

O2 EC 0.02% 0.0-25.0% ±0.1% ±5%

Response time: less than 10s(HC,CO,CO2), less than 12s(O2), less than 15s(NO)

Warm-up time less than 15min (1 min warm up for urgent measurement)

Power Supply AC220V ±10% 50Hz ±1Hz,150W

Net Weight 8.5kg

Dimension(W*H*D) 46*23*24m

Package Dimension Carton:59.5*31*34.5cm

www.zdmq.com

Page 9: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

MQW-50A High Precision Five gas Analyzer

2. Strategy

1. Introduction

Automatic measure the concentration of HC,CO,CO2,O2 and NOx.

NDIR gas sensor,HORIBA bench from Japan,OIML class 00 accuracy.

Automatic zero resetting

high-brightness LCD display, automatic linear data process

Automatic calculation and display of Air-Fuel Ratio λ

RPM and oil temperature measurement interface.

With functions of License Plate Number Input and time display

4000 sets of data storage and intelligent review

Update the software by connecting with computer through RS-232

interface

Easy operation, accurate measurement and reliable performance

Optional micro printer and RPM meter.

Suitable for ASM, VMAS emission test.

Technical Data

ITEM Method Resolution Measurement RangeAbsolute

Accuracy

Relative

Accuracy

HC NDIR 1ppm0-2000ppm ±4ppm ±3%

2001-5000ppm ±5%

CO NDIR 0.01%5001-9999ppm ±10%

0.00-10% ±0.02% ±3%

CO2 NDIR 0.1% 10.01-15.00% ±5%

NO EC 1ppm0.0-16.0% ±0.3% ±3%

16.1-18.0% ±5%

O2 EC 0.02% 0-4000ppm ±25ppm ±4%

Response time less than 8s(HC,CO,CO2), less than 12s(O2), less than 15s(NO)

Warm-up time less than 30min (1 min warm up for urgent measurement)

Power Supply AC220V ±10% 50Hz ±1Hz,300W

Net Weight 15kg

Dimension(W*H*D) 55*23*48.5cm

Package Dimension Carton:62*58*37cm

www.zdmq.com

Page 10: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

MQY-200 Diesel Smoke Meter /Opacimeter

2. Strategy

1. Introduction

www.zdmq.com

Separated measure unit and control unit for easy operation.

Advanced divided flow technology,constant temperature control in the testing room

Large LCD screen with reading of opacity and light absorption coefficient.

Fast warm up, automatic zero and calibration check.

With functions of free acceleration test and dynamic measurement

License Plate Number input,500 data storages and intelligent review.

RPM and oil temperature measurement.

RS-232 interface

Optional Micro printer and RPM Meter.

Suitable for free Accelerate & LUGDOWN emission test.

Technical Data

ITEM ResolutionMeasurement Range

Absolute Accuracy Relative Accuracy

Opacity(N) 0.01% 0-99.90% ±2%

Optical Absorption Coefficient(K)

0.01m-1 0- 16.08m-1 0.05m-1

RPM 1rpm 300-9999ppm 50rpm

Oil Temperature 1℃ 0-200℃ ±5℃

Gas Temperature 1℃ 0-150℃ ±5℃

Warm up time Less than 15 min (5 min warm up for urgent measurement)

Power Supply: AC 220V±10%,50±1Hz,250W

Efficient length of

Optical Path215mm

Net Weight 5kg(Control unit) 7kg(Measure unit)

Dimension(W*H*

D)

Control unit: 35.3*21*24.8cm

Measure unit: 43*26*17.5cm

Package

DimensionCarton:51.5*50*36cm

Page 11: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

ML-100 Automotive Exhaust Flow Meter

1. Introduction

www.zdmq.com

Measure the exhaust flow of petrol engine vehicles.

Equipped with advanced imported ultrasonic sensor and

zirconia sensor to make the measure easy and accurate.

Equipped with unique and patented current stabilizer,in

excellent stability and repeatability.

Suitable for VMAS emission test.

Technical Data

ITEM ResolutionMeasurement Range

Absolute Accuracy Relative Accuracy

Exhaust Flow 0.01 m3/min 4-12 m3/min ±4%(F.S)

Oxygen 0.1% vol 0.3- 25% vol ±0.5% ±5%

Internal Temperature

0.1℃ -30℃-150℃ ±1℃

Pressure 0.1k Pa70.0k Pa -110.0kPa

±3%

Warm-up Time less than 3min

Oxygen Response Time 12s

Power Supply AC 220V±10%,50±1Hz, 1KW

Net Weight 65kg

Dimension(W*H*D) 142*90*45cm

Package Dimension Wooden Case:156*75*105cm

Page 12: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

MQL-8201 Fuel Consumption Meter for Commercial Vehicles

2. Strategy

1. Introduction

Test the fuel consumption of 100km with chassis

dynamometer by principle of carbon balance method.

Measure exhaust concentration by NDIR bench, high

accuracy of OIML class 00.

Measure the diluted exhaust flow by V-type cone flow

meter,with high accuracy of 0.5% and self-cleaning

function, excellent stability and durability.

Work for almost all the Petrol and Diesel Commercial

Vehicles.

Equipped with advanced high-pressure & large-flow

fan in variable frequency control technology,to ensure

the accuracy of exhaust flow and concentration in wide

dynamic range.

Suitable for Vehicles Comprehensive Inspection

Stations.

Technical Data

ITEM ResolutionMeasurement Range

Absolute Accuracy

Relative Accuracy

Repeatability

CO 0.001% 0-1% ±0.02% ±2%

CO2 0.01% 0-5% ±0.02% ±2%

HC 1ppm 0-500ppm ±4ppm ±3%

Flow 0.01m3/min 6-20m3/min ±1% ±0.5%

Fuel Consumption

0.01(ml/s) 0-15(ml/s) ±4% ±1.5%

Power Supply

AC220V ±10% ,50±1Hz,300W/AC380V±10% ,50±1Hz,4KW

Pressure 76kPa -106kPa

Dimension (W*H*D)

173*86*60cm

www.zdmq.com

Page 13: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

MQW-5101 Diesel Exhaust NOx Gas Analyzer

2. Strategy

1. Introduction

Measures the Diesel NOx gas concentration

Imported NDIR optical bench, OIML class 00 accuracy.

Multi-filter system, protecting NDIR bench and gas circuit, easy

changeable filter.

Sampling system in constant temperature, to prevent water from

condensation and keep measurement accurate.

Using NOx transfer system at high 90% transfer rate

Built-in Electronic Rapid condensing system

ARM9-based Embedded software, smart-touch buttons and

other interfaces, etc

Also offering data of ambient humidity, pressure, RPM and oil

temperature.

Equipped with flexible trolley, easy operation and convenient.

Smart Protecting and diagnostic functions.

Suitable for Vehicle Inspection stations and auto service shops.

www.zdmq.com

Technical Data

Measurement Range 0 to 5000 ppm VOL

Accuracy0-4000ppm:±25ppm(Absolute Error) ±4%(Relative Error)

4001-5000ppm :±8%

Resolution 1ppm VOL

Response Time Less than 15s

Operating Temperature 0℃-50℃

Power supply AC220V ±10% 50 ±1Hz

Page 14: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

MQZ-2 Cigar-Lighter Engine RPM Meter

2. Strategy

1. Introduction

www.zdmq.com

Measure the Engine speed of most petrol and diesel vehicles.

Easy set and read in the operation interface.

RS232 interface

Easy operation, just plug the cable onto the cigarette socket, RPM directly displayed.

Suitable for MQ-550,MQW-50A Vehicle Exhaust Gas Analyzer and MQY-200 Diesel

Smoke Meter.

Technical Data

Measurement Range 400-9999rpm

Accuracyless than 10rpm(400-2000rpm)

less than 1%(2001-9999rpm)

Initialization Time less than 17s

Refreshing Rate 10 times/second

Power Supply DC12V(9V-15V)

Supply Current less than 500mA

Net Weight 385g

Dimension(W*H*D) 9.8*14.4*4cm

Package Dimension Carton:36*23*12cm

Page 15: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

MQZ-3 Vibration Engine RPM Meter

2. Strategy

1. Introduction

www.zdmq.com

Measure the engine speed of petrol and diesel vehicles by vibration signal

analysis

Vibration sensor,RS232 interface

Continuous testing to avoid repeated initialization,ideal for on-site testing.

Easy operation, just attach the probe on the engine or vehicle rack,RPM directly

displayed.

Suitable for MQ-550,MQW-50A Exhaust Gas Analyzer and MQY-200 Diesel

Smoke Meter.

Technical Data

Measurement Range 400-9999rpm

Accuracyless than 10rpm(400-2000rpm)

less than 1%(2001-9999rpm)

Response Time less than 1s

Refreshing Rate 10 times/second

Baud Rate 9600bps

Power Supply DC12V(9V-15V)

Supply Current 400mA

Net weight 385g

Dimension(W*H*D) 9.8*14.4*4cm

Package Dimension Carton:36*23*12cm

Page 16: High Quality Vehicle Headlight Tester & Emission Gas Analyzer Catalog 201411.pdf · ML-100 Automotive Exhaust Flow Meter 1. Introduction Measure the exhaust flow of petrol engine

Thanks for your

visiting

&

Expect our

cooperation!

Zhejiang University Mingquan Scien-Tech Co.,Ltd

Address:Building 2,No.8 Xiyuan Road,Westlake

District,Hangzhou310030,China.

Tel./Fax:+86-571-87972473

E-mail:[email protected]

www.zdmq.com