High Pressure Filters 15P/30P Series - H & P...

34
High Pressure Filters 15P/30P Series MAX 200 I/min - 207 bar High pressure filters 103

Transcript of High Pressure Filters 15P/30P Series - H & P...

Page 1: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

15P/30P SeriesMAX 200 I/min - 207 bar

High pressure filters103

Page 2: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

15P/30P SeriesFeatures & Benefits

Parker HannifinFilter Division EuropeFDHB200UK. Section 13

104

The Parker Filtration 15P/30P SeriesHigh Pressure Filters.These application examples have one thing incommon...the need for clean hydraulic fluid.

Modern high pressure hydraulic systems aredemanding. Better controls and long componentlife are expected. To deliver the high standards ofperformance, hydraulic components are built withtighter tolerances which increases their sensitivityto contamination.

That’s where Parker pressure filters come into play.They filter out ingressed contamination before itjams a valve or scores a cylinder. They block pumpgenerated debris before it gets to servo orproportional valves. Parker pressure filters are akey ingredient in meeting today’s system demands.

Put your hydraulic systems in the care of ParkerFiltration. We are committed to designing andbuilding the best filters available to industry.

Features

Compact aluminium housing

Two head sizes and two bowllengths

Large ports and wide flow paths

Microglass III replacement elements

Visual, electrical and electronicindicators available

Advantages

Light weight but still robust design

Optimised sizing

Low differential pressure across housing and element

Multi-layered design produced high capacity and efficiency

Wire support reduces pleat bunching, keepsperformance consistent

Check element condition at a glance

Right style for the application

Benefits

Reliable and continuous operation bothin mobile and industrial applications

Efficient filtration

Right filter for each application

Higher flow rates possible

Less lost energy

Great performance value

Reliable performance throughoutelement life

Reduces downtime, maximises element life

Optimise element life, prevent bypassing

Matches your system electricalconnections

Typical Applications

Saw millsAircraft ground support equipmentAsphalt paversHydraulic fan drivesPower steering circuitsDomestic refuse vehiclesCement trucksServo control protectionLogging equipment

Page 3: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High pressure filters

Installation Details

Specification

Pressure ratings:Maximum allowable operating pressure 207 bar.Filter housing pressure pulse fatigue tested: 138 bar.Connections:Inlet and outlet connections are threaded.Connection style Model

15P 30PBSPF(G) 3/4” 1”ISO 6149 M27 M33

Filter housing:Head material extruded aluminium (anodised 6061-T6).Bowl material impacted aluminium (anodised 6061-T6).Seal material:Nitrile or Fluoroelastomer.Operating temperature range:-20°C to +100°C.Bypass valve:Opening pressure 3.5 bar.Filter element:Degree of filtration:Determined by multipass-test according to ISO 16889, see Box 3 in the product configurator.

Flow fatigue characteristics:Filter media is supported so that the optimal fatigue life is achieved (ISO 3724).Microglass III:Supported with epoxy coated metal wire mesh, end cap materialreinforced composite and metal inner core. Collapse rating 24 bar (ISO 2941).High collapse elements:High collapse elements available. For details please contact Parker Filtration.Indicator options:Indicating differential pressure: 2.5 ± 0.2 bar.- visual M3.- electrical T1.- electronic F1(PNP).- electronic F2(NPN).For indicator details see catalogue section 6.Weights (kg):Model Length 1 Length 215P 1.6 2.130P 2.9 3.9Fluid compatibility:Suitable for use with mineral and vegetable oils, and some synthetic oils. For other fluids, please consult Parker Filtration.

105

Bottom View

64.32.53

23.9.94

49.01.93

155.36.11

15P-1

15P-1

173.5-2.36.83-0.9

50.82.00

Minimumcartridge removal

clearance

Optional 5/16 SAE-5drain porttorque 20-27 Nm(15-20 ft lbs)

Torque 40-48 Nm

Torque 74-95 Nm(55-70 Ft lbs)

101.64.0023.0

.91

50.51.99

46.01.81

79.431.3

Dia.

21.8.86

25.41.000

62.52.46

6.22.25

250.49.86

15P-2268.7–.2.310.58–.09

15P-2

6.8–.13.266–.005

79.4–.133.125–.005

15P Series

Page 4: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

15P/30P SeriesInstallation Details (cont.)

Parker HannifinFilter Division EuropeFDHB200UK. Section 13

106

1 Head2 Bypass assembly3 Element See chart in product configurator4 Bowl O-ring – buna N92138 N92151

Bowl O-ring – fluoroelastomer V92138 V921515 Bowl6 Drain plug – c/w buna seal

Drain plug – c/wFluoroelastomer seal

7 Nameplate10 Blank indicator kit11 Indicators

M3 – Visual auto reset indicator FMUM3KVAU14MT1 – Electrical indicator FMUT1KVAU14MF1 – Electronic indicatorPNP with 4 LED FMUF1KVAU14MF2 – Electronic indicatorNPN with 4 LED FMUF2KVAU14M

Index Description 15P 30P

66.72.63

90.13.55

Torque 74-95 Nm (55-70 Ft lbs)

3.0.12

51.42.02

210.08.27

30P-1 30P-1

229.69.04

Torque 88-95 Nm(65-70 Ft lbs)

Optional str thd drain port5/16 SAE-5 (11/2-20 UNF-2B)Torque 20-27 Nm (15-20 Ft lbs)

101.64.00

Minimumcartridgeremoval

clearance

Side view

69.92.750

34.91.375 10.3

.406dia thru 2 total

19.1.75

31.81.25

Optional mounting bracket (925563)

101.64.000

Port to port

52.32.06

92.13.63

dia

28.81.12

Hex

Bottom view104.84.13

dia

24.4.96

338.813.34

30P-2

75.22.96

319.312.5730P-2

mm(inches)

30P Series

1

2

3

4

5

6

6

5

4

3

1

7

10

11

Page 5: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High pressure filters

Pressure Drop Curves

107

The recommended level of the initial pressure drop is max. 1.2 bar.If the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows:Δp = (Δp30 x viscosity of medium used) / 30 cSt.

15P-1 Elements

15P-2 Elements

15P Empty Housing

25

20

15

5

0

10

Flow (US GPM)

Flow (l/min)20 40 60

0.0

Δp (b

ar)

0.5

1.0

1.5

0

10 15 20 2550

80 100

02Q

05Q

20Q

10Q

Δp (P

SID

)

Δp (b

ar)

0 20 40 60 80

Flow (l/min)

Flow (US GPM)

Δp (P

SID

)

0 5 10 15 20 2525

20

15

10

5

0

1.5

1.0

0.5

0.0

15P-115P-2

25

20

15

5

0

10

Flow (US GPM)

Flow (l/min)20 40 60

0.0

Δp (b

ar)

0.5

1.0

1.5

0

10 15 20 2550

80 100

02Q

05Q

20Q10Q

Δp (P

SID

)

30P-1 Elements

30P Empty Housing

25

20

15

5

0

10

Flow (US GPM)

Δp (P

SID

)

Flow (l/min)

0.0

Δp (b

ar)

0.5

1.0

1.502Q

05Q

20Q

10Q

0 13 26 66

50 100 2502000

53

150 300

39 79

Δp (b

ar)

0 50 100 150 200

Flow (l/min)

Flow (US GPM)

Δp (P

SID

)

0 10 20 40 50 6025

20

15

10

5

0

1.5

1.0

0.5

0.0

30P-130P-2

30

30P-2 Elements

25

20

15

5

0

10

Flow (US GPM)

Δp (P

SID

)

Flow (l/min)

0.0

Δp (b

ar)

0.5

1.0

1.5

02Q

05Q

20Q

10Q

0 13 26 66

50 100 2502000

53

150 300

39 79

Page 6: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

15P/30P SeriesOrdering Information

Parker HannifinFilter Division EuropeFDHB200UK. Section 13

108

Note: Filter assemblies ordered from the product configurator below are on extended lead times. Where possible, please make your selection from the table above.

Part number

15P110QBM3KG12115P110QBT1KG12115P210QBM3KG12115P210QBT1KG12130P110QBM3KG16130P110QBT1KG16130P210QBM3KG16130P210QBT1KG161

Supercedes

15P-1-10Q-M2-50-B2B2-115P-1-10Q-TW3-50-B2B2-115P-2-10Q-M2-50-B2B2-115P-2-10Q-TW3-50-B2B2-130P-1-10Q-M2-50-C2C2-130P-1-10Q-TW3-50-C2C2-130P-2-10Q-M2-50-C2C2-130P-2-10Q-TW3-50-C2C2-1

Flow(l/min)

45457070120120170170

Modelnumber

15P15P15P15P30P30P30P30P

Elementlength

Length 1Length 1Length 2Length 2Length 1Length 1Length 2Length 2

Mediarating (μ)

1010101010101010

Seals

NitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrile

Indicator

VisualElectrical

VisualElectrical

VisualElectrical

VisualElectrical

Bypasssettings

3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar

Replacementelements

939102Q939102Q939106Q939106Q939110Q939110Q939114Q939114Q

Ports

G3/4"G3/4"G3/4"G3/4"G1"G1"G1"G1"

Product configuratorBox 1

Code12

LengthLength 1Length 2

Filter typeBox 2

15PBox 2

1Box 3

10QBox 4

BBox 5

M3Box 6

KBox 7

G12Box 8

1

CodeBV

Seal materialNitrileFluoroelastomer

Seal typeBox 4

Bypass valve3.5 bar

Bypass and indicator settingsIndicator

2.5 barCode

K

Box 6

CodeP

M3T1NF1F2F3F4

Plugged with steel plugVisual indicatorElectrical indicatorNo indicator portElectronic 4 LED, PNP, N.O.Electronic 4 LED, NPN, N.O.Electronic 4 LED, PNP, N.C.Electronic 4 LED, NPN, N.C.

IndicatorBox 5

CodeG12M27G16M33

Connections15P: Thread G13/4

Thread M27, ISO 614930P: Thread G 1

Thread M33, ISO 6149

Filter connectionBox 7

Code14

OptionsStandardDrain port on bowl

OptionsBox 8

Code15P30P

ModelHigh pressure filter, T-portHigh pressure filter, T-port

CodeBox 1

Standard products table

Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.

Media02Q05Q10Q20Q

Replacement elements with nitrile seals15P-1

939100Q939101Q939102Q939103Q

15P-2939104Q939105Q939106Q939107Q

30P-1939108Q939109Q939110Q939111Q

30P-2939112Q939113Q939114Q939115Q

Filter model15P-115P-230P-130P-2

Nominal flow (I/min) at viscosity 30 cSt02Q254070120

05Q306090

150

10Q4570

120170

20Q7090170200

When filter includes a bypass valve but not an indicator,code denotes bypass setting.

Item is standardItem is standard with “green” optionsItem is semi standardItem is non standard

123123123123

Highlights Key (Denotes part number availability)

Note: Standard items are in stock, semi standard items are available within four weeks

Box 3

Element media

Microglass III element20μ media

20Q10μ media

10Q5μ media

05Q2μ media

02Q

Glass fibre

Degree of filtration

Average filtration beta ratio ß (ISO 16889) / particle size μm [c]

% efficiency, based on the above beta ratio (ßx)ßx(c)=2

50.0%N/AN/AN/A6

Degree of filtrationCode

ßx(c)=10

90.0%N/AN/A611

ßx(c)=75

98.7%N/A4.58.517

ßx(c)=100

99.0%N/A5918

ßx(c)=200

99.5%N/A61020

ßx(c)=1000

99.9%4.571222

02Q05Q10Q20Q

DisposableMicroglass III

Page 7: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

100P SeriesMAX 1000 I/min - 414 bar

High pressure filters109

Page 8: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

100P Series

Typical Applications

Drilling rigsPower packsOil/gas industryFlight simulatorsTest rigs

The Parker Filtration Model 100P High Pressure Filters.The 100P Series is designed to meet the growingdemand for high-pressure filters with a flow rate capacityof up to 1000 l/min at 414 bar working pressure. For systems where reverse flow can be expected, anoptional integrated reverse flow valve avoids back washof contamination. When changing the element, only theend cap of the bowl has to be removed. The filter isideal for applications where space is at a premium. Thefilter media used in the elements is high qualityMicroglass III glass fibre.

Features & Benefits

Parker HannifinFilter Division EuropeFDHB200UK. Section 14

110

Features

High 414 bar pressure rating

Flow rates up to 1000 l/min

Optional reverse flow valve

Bottom access bowl

Microglass III replacement elements

Visual and electrical indicatorsavailable

Advantages

Strong and robust housing for heavy dutyapplications

Pressure filtration possible for high flow rates

Allows reverse flow and prevents back wash of element

Only bottom of the bowl must be opened forelement change

Multi-layered design produced high capacity and efficiency

Wire support reduces pleat bunching, keepsperformance consistent

Check element condition at a glance

Right style for the application

Benefits

Reliable and continuous operation foropen and closed loop applications

Excellent protection of highperformance machinery

Ideal for applications where back flowis expected

Easy service

Great performance value

Reliable performance throughoutelement life

Reduces downtime, maximises element life

Optimises element life, preventsbypassing

Matches your system electricalconnections

Page 9: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

1

2

3/3A

3/3A

4

5

6

7

8

9

1013

11

12

14

15

Ø169

Ø125

Ø145

Ø145

107.

510

588

35

235

15

SAE 646 A/F

Min

imum

ele

men

tcl

eara

nce

330/

580

L1=

563

L2=

813

10055A/F

High pressure filters

Installation Details

Specification

Pressure ratings:Maximum allowable operating pressure 414 bar.Filter housing pressure pulse fatigue tested: 3*106 pulses 0 - 276 bar.Connections:Inlet and outlet connections are threaded internally or flange faced.Threads G11/2”, G2” (ISO 228/1), SAE 24, SAE 32.or flanges 11/2" SAE 6000, 2” SAE 6000, 11/2" SAE 6000-M, 2” SAE 6000-M.*6000-M is a SAE style with appropriate metric fixing threads.Filter housing:Head material cast iron (GSI).Bowl material extruded steel, max torque 200 Nm.Seal material:Nitrile or Fluoroelastomer, Neoprene.Operating temperature range: - 20°C to +100°C.Bypass valve:Opening pressure 7.0 bar.Options:Reverse flow valve, which directs back flow from port to port.

Filter element:Degree of filtration:Determined by Multipass-test according to ISO 16889, see Box 3 in the product configurator.Flow fatigue characteristics:Filter media is supported so that the optimal fatigue life is achieved (ISO 3724).Microglass III:Supported with epoxy coated metal wire mesh, end cap material reinforced composite and metal inner core. Collapse rating 20 bar (ISO 2941).High collapse elements:High collapse elements available. For details please contact Parker Filtration.Indicator options:Indicating differential pressure: 5.0 bar.- visual indicator.- electrical indicator.Weights (kg):100P-1: 37 kg.100P-2: 47 kg.Fluid compatibility:Suitable for use with mineral and vegetable oils, and some synthetic oils. For other fluids, please consult Parker Filtration.

111

1 Filter head2 Filter element3 Bowl seal

3A Bowl back-up ring4 Housing5 Cover6 Indicator seal7 Bypass set8 Visual indicator9 Electrical indicator10 Bypass seal11 Reverse flow set12 Adaptor13 Adaptor/reverse flow seal14 Cover seal15 Drain plug16 Mounting clamp

Type H model 1000

Steel (Zinc plated)

M12x75(2x)(81.21.022.20)

188

138100

EPDM

2.5

Ø125

70

3

308

13

3

Mounting Clamp Item 16

Page 10: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

100P SeriesAdditional Information

Parker HannifinFilter Division EuropeFDHB200UK. Section 14

112

Flow (l/min)

Δp (b

ar)

0

0.2

0.4

0.6

0.8

1

1.2

1.6

1.4

2

1.8

0 100 200 300 400 500 600 700 800

RFV

Flow (US GPM)

159132 185 21179 106260 53

Δp (P

SID

)

02.95.8

11.68.7

14.517.420.323.226.129

Normalhousing

Flow (l/min)

Δp (b

ar)

0

0.2

0.4

0.6

0.8

1

1.2

1.6

1.4

2

1.8

0 100 200 300 400 500 600 700 800

Flow (US GPM)

159132 185 21179 106260 53

Δp (P

SID

)

02.95.8

11.68.7

14.517.420.323.226.129

02Q

05Q10Q

20Q

100P-1 Empty Housing (G11/2”, SAE 24, SAE 11/2”)

100P-1 Elements

Flow (l/min)

Δp (b

ar)

0

0.2

0.4

0.6

0.8

1

1.2

1.6

1.4

2

1.8

0 100 200 300 400 500 600 700 800 900 1000

RFV

Flow (US GPM)

159132 211185 238 26479 106260 53Δp

(PS

ID)

02.95.8

11.68.7

14.517.420.323.226.129

Normalhousing

Flow (l/min)

Δp (b

ar)

0

0.2

0.4

0.6

0.8

1

1.2

1.6

1.4

2

1.8

0 100 200 300 400 500 600 700 800 900 1000

Flow (US GPM)

159132 211185 238 26479 106260 53

Δp (P

SID

)

02.95.8

11.68.7

14.517.420.323.226.129

02Q

05Q

10Q

20Q

100P-2 Empty Housing (G2”, SAE 32, SAE 2”)

100P-2 Elements

Circuit symbol

Filter withReverse Flow Valve

Normal Flow Condition

Reverse Flow Condition

Valve housing

Valve housing

Sleeve

Central stem

Pressure Drop Curves

The recommended level of the initial pressure drop is max. 2.3 bar.If the medium used has a viscosity different from 30 cSt, pressure drop can be estimated as follows:The total Δp = housing Δph + (element Δpe x working viscosity/30).

Page 11: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High pressure filters

Ordering Information

113

Note: Filter assemblies ordered from the product configurator below are on extended lead times. Where possible, please make your selection from the table above.

Part number

100P105QBM4MF241100P110QBM4MF241100P120QBM4MF241100P205QBM4MF321100P210QBM4MF321100P220QBM4MF321

Supercedes

1074A.2HN70.FZ12101074A.2HN70.FZ12201074A.2HN70.FZ12301074A.2HN70.TZ22101074A.2HN70.TZ22201074A.2HN70.TZ2230

Flow(l/min)

600700800840920

1000

Modelnumber

100P100P100P100P100P100P

Elementlength

Length 1Length 1Length 1Length 2Length 2Length 2

Mediarating (μ)

5102051020

Seals

NitrileNitrileNitrileNitrileNitrileNitrile

Indicator

VisualVisualVisualVisualVisualVisual

Bypasssettings

7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar

Replacementelements

939061Q939062Q939063Q939065Q939066Q939067Q

Supercedes

1070Z121A1070Z122A1070Z123A1070Z221A1070Z222A1070Z223A

Ports

SAE flange 11/2" 6000SAE flange 11/2" 6000SAE flange 11/2" 6000SAE flange 2" 6000SAE flange 2" 6000SAE flange 2" 6000

Product configuratorBox 1

Code12

LengthLength 1Length 2

Filter typeBox 2

100PBox 2

2Box 3

10QBox 4

BBox 5

M4Box 6

MBox 7

F32Box 8

1

CodeBV

Seal materialNitrileFluoroelastomer

Seal typeBox 4

Bypass valve7.0 bar

Bypass and indicator settingsIndicator

5.0 barCode

M

Box 6

CodeN

M4T2T3T4T5

No indicator portVisual indicatorElectrical indicatorElectrical indicator with red lamp 28 Vdc, N.O.Electrical indicator with red lamp 110 VAC, N.O.Electrical indicator with red lamp 250 VAC, N.O.

IndicatorBox 5

CodeG24G32S24S32F24H24F32H32

ConnectionsThread G 11/2

Thread G 2Thread SAE 24Thread SAE 32SAE flange 11/2" 6000SAE flange 11/2" 6000-MSAE flange 2" 6000SAE flange 2" 6000-M

Filter connectionBox 7

Code13

OptionsStandardReverse flow valve

OptionsBox 8

Code100P

ModelLarge HP filter, L-port

CodeBox 1

Standard products table

Media02Q05Q10Q20Q

Replacement elements with nitrile sealsLength 1939060Q939061Q939062Q939063Q

Length 2939064Q939065Q939066Q939067Q

Filter port size100P-1, 11/2"100P-2, 2"

Nominal flow (I/min) at viscosity 30 cSt02Q540700

05Q600840

10Q700920

20Q800

1000

Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.

Seal kit (nitrile) order code: 8069000070Mounting clamp order code: 84.47.265.01

When filter includes a bypass valve but not an indicator,code denotes bypass setting.

Average filtration beta ratio ß (ISO 16889) / particle size μm [c]

% efficiency, based on the above beta ratio (ßx)ßx(c)=2

50.0%N/AN/AN/A6

Degree of filtrationCode

ßx(c)=10

90.0%N/AN/A611

ßx(c)=75

98.7%N/A4.58.517

ßx(c)=100

99.0%N/A5918

ßx(c)=200

99.5%N/A61020

ßx(c)=1000

99.9%4.571222

02Q05Q10Q20Q

DisposableMicroglass III

Box 3

Element media

Microglass III element20μ media

20Q10μ media

10Q5μ media

05Q2μ media

02Q

Glass fibre

Degree of filtration

Item is standardItem is standard with “green” optionsItem is semi standardItem is non standard

123123123123

Highlights Key (Denotes part number availability)

Note: Standard items are in stock, semi standard items are availablewithin four weeks

Page 12: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

Parker HannifinFilter Division EuropeFDHB200UK.

114

Notes

Page 13: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

18/28/38P SeriesMAX 700 I/min - 414 bar

High pressure filters115

Page 14: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

18/28/38P Series

Typical Applications

Injection mouldingDie castingServo controlsMachine toolsMobile equipment

The Parker Filtration 18/28/38P SeriesHigh Pressure FiltersParker Filtration engineered the 18/28/38P series of high pressure filtersto satisfy demanding applications in the mobile and industrial marketsthroughout the world. With metric mounting and optional ISO 6149ports, this new series is truly a global design.

Installed downstream of the pump, this new series with their wide rangeof high capacity Microglass III elements, offer excellent protection tosystem components.

Standard filters come complete with industry proven spool type bypassvalve. For more critical applications such as servo or proportionalcontrols, a no bypass high strength element combination ensuresmaximum protection.

The modular low hysteresis differential pressure indicator fitted to thisseries is unrivaled in its performance. Tests prove its accuracy andfoolproof design to be a major advance in indicator technology.

Features & Benefits

Parker HannifinFilter Division EuropeFDHB200UK. Section 15

116

Features

Fatigue tested to full pressure rating

Several head sizes

Several connection options

Microglass III replacement elements

Visual, electrical and electronicindicators available

Advantages

Strong and robust housing for heavy dutyapplications

Optimised sizing

Easy mounting

Multi-layered design produced high capacity andefficiency

Wire support reduces pleat bunching, keepsperformance consistent

Check element condition at a glance

Right style for the application

Benefits

Reliable and continuous operation bothin mobile and industrial applications

Efficient filtrationCovers wide flow range

Global design, global acceptanceRight filter for each application

Great performance valueReliable performance throughoutelement lifeReduces downtime, maximises element lifeOptimises element life, preventsbypassingMatches your system electricalconnections

Page 15: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

18P 28P 38P

B C

Torque22-27Nm

(15-20 ft/lbs)

A Length 1

A Length 2

Hex. E

Bowl removalF

CB

A Length 1

A Length 2

Bowl removalF

Hex.

Torque35-40 Nm

(25-30 ft/lbs)

B C

A Length 1

A Length 2

Bowl removalF

Torque80-95 Nm

(60-70 ft/lbs)

Hex.

K

H

J

LN

M

15°

4 mounting holes (P)

G

H

J

K

LM

N

4 mounting holes (P)

15°R30 R3

5

G

JH

NM

15°

LK

4 mounting holes (P)

mm(inches)

D DD

G

R38

EE

High pressure filters

Specification

Pressure ratings:Maximum allowable operating pressure 414 bar.Filter housing pressure pulse fatigue tested: 106 pulses 0 - 414 bar.Connections:Inlet and outlet connections are threaded internally or flange faced.Connection style Model

18P 28P 38PBSPF(G) 3/4” 1” 11/4”, 11/2”SAE 12 16 20, 24ISO 6149 M27 M33 M42, M48Flange SAE 6000 3/4” 1” 11/4”Flange SAE 6000-M* 3/4” 1” 11/4”*6000-M is a SAE style with appropriate metric fixing threads.Filter housing:Head material cast iron (GSI).Bowl material steel.Seal material:Nitrile or Fluoroelastomer.Operating temperature range:-20°C to +100°C.Bypass valve & indicator settings:Table below gives bypass valve and corresponding indicator setting.Bypass Indicator3.5 bar 2.5 bar7.0 bar 5.0 bar

117

Filter element:Degree of filtration:Determined by multipass-test according to ISO 16889, see Box 3 in theproduct configurator.Flow fatigue characteristics:Filter media is supported so that the optimal fatigue life is achieved (ISO 3724).Microglass III:Supported with epoxy coated metal wire mesh, end cap material reinforcedcomposite and metal inner core. Collapse rating 20 bar (ISO 2941).High collapse elements:(to be used when no bypass function in filter housing).Microglass III media supported with epoxy coated metal wire mesh onupstream and stainless steel on downstream, end cap material steel.Strong metal inner core. Collapse rating 210 bar (ISO 2941).Indicator options:Indicating differential pressure: 2.5 ± 0.2 bar or 5.0 ± 0.4 bar.- visual M3.- electrical T1.- electronic F1(PNP).- electronic F2(NPN).For indicator details see catalogue section 6.Weights (kg):Model Length 1 Length 218P 4.2 5.728P 6.7 9.238P 15.8 20.3Fluid compatibility:Suitable for use with mineral and vegetable oils, and some synthetic oils. For other fluids, please consult Parker Filtration.

Model

198(7.79)293

(11.53)228

(8.97)337

(13.26)329

(12.95)448

(17.64)

32(1.26)

40(1.57)

44(1.73)

26(1.02)

29(1.14)

35(1.38)

75(2.95)

93(3.66)

128(5.04)

24(0.94)

24(0.94)

36(1.42)

100(3.94)

98(3.86)

120(4.72)

160(6.30)

40(1.57)

55(2.16)

50(1.97)

20(0.79)

27.5(1.07)

25(0.98)

80(3.15)

90(3.54)

120(4.72)

40(1.57)

45(1.77)

60(2.36)

55(2.16)

62(2.44)

81(3.19)

110(4.33)

124(4.88)

162(6.38)

M8 x 1.25x12

deep

M10 x 1.5x11

deep

M10 x 1.5x12

deep

18P-1

18P-2

28P-1

28P-2

38P-1

38P-2

A B C D E F G H J K L M N P(A/F)

Page 16: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

18/28/38P SeriesFlange Face Details

Parker HannifinFilter Division EuropeFDHB200UK. Section 15

118

Modelmm (inches)

11.9

(0.47)

14

(0.55)

15.7

(0.62)

23.8

(0.94)

27.8

(1.09)

31.7

(1.25)

25.4

(1.00)

28.0

(1.10)

33.0

(1.30)

50.8

(2.0)

57.1

(2.25)

66.7

(2.62)

M10 x 1.5-6H x 18 Deep

M12 x 1.75-6H x 20 Deep

M14 x 2-6H x 20 Deep

3/8-16 UNC-2B x 18 deep

7/16-14 UNC-2B x 20 deep

1/2-13 UNC-2B x 20 deep

19.0

(0.75)

25.4

(1.0)

31.8

(1.25)

18P (3/4”)

28P (1”)

38P (11/4”)

A B C D E F G

C

D

AB

ØG

Thread E metricF SAE

Page 17: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High pressure filters

Pressure Drop Curves

119

18P-1 Empty Housing and High Collapse

28P-1 Elements

18P-1 Elements

18P-2 High Collapse Elements

28P-2 Elements

43.5

29.0

0

0 5 11 21

Flow (US GPM)

Flow (l/min)20 40 8060

0.0

Δp (b

ar)

20QH1.0

2.0

3.0

0

0.5

1.5

2.5

16

14.5

Δp (P

SID

)

10QH

05QH

02QH

Empty Housing

100

26

43.5

29.0

0

0 5 11 21

Flow (US GPM)

Flow (l/min)20 40 8060

0.0

Δp (b

ar)

20QH

1.0

2.0

3.0

0

0.5

1.5

2.5

16

14.5

Δp (P

SID

)

10QH05QH

02QH

100

26

43.5

29.0

0

0 13 26 66

Flow (US GPM)

Flow (l/min)50 100 250200

0.0

Δp (b

ar)

20Q1.0

2.0

3.0

0

0.5

1.5

2.5

53

14.5

Δp (P

SID

)

10Q

05Q

02Q

150 300

39 79

43.5

29.0

0

0 5 11 21

Flow (US GPM)

Flow (l/min)20 40 8060

0.0

Δp (b

ar)

20Q

1.0

2.0

3.0

0

0.5

1.5

2.5

16

14.5

Δp (P

SID

)

10Q05Q

02Q

100

26

18P-2 Elements

43.5

29.0

0

0 5 11 21

Flow (US GPM)

Flow (l/min)20 40 8060

0.0Δp

(bar

)20Q

1.0

2.0

3.0

0

0.5

1.5

2.5

16

14.5

Δp (P

SID

)

10Q05Q

02Q

100

26

43.5

29.0

0

0 13 26 66

Flow (US GPM)

Flow (l/min)50 100 250200

0.0

Δp (b

ar)

20Q1.0

2.0

3.0

0

0.5

1.5

2.5

53

14.5

Δp (P

SID

)

10Q05Q

02Q

150 300

39 79

28P-1 Empty Housing and High Collapse 28P-2 High Collapse Elements

43.5

29.0

0

0 13 26 66

Flow (US GPM)

Flow (l/min)50 100 250200

0.0

Δp (b

ar)

20QH

1.0

2.0

3.0

0

0.5

1.5

2.5

53

14.5

Δp (P

SID

)

10QH05QH02QH

150 300

39 79

Empty Housing

43.5

29.0

0

0 13 26 66

Flow (US GPM)

Flow (l/min)50 100 250200

0.0

Δp (b

ar) 20QH

1.0

2.0

3.0

0

0.5

1.5

2.5

53

14.5

Δp (P

SID

)

10QH05QH02QH

150 300

39 79

With 3.5 bar bypass the recommended initial pressure drop is max 1.2 bar.With 7.0 bar bypass the recommended initial pressure drop is max 2.3 bar.If the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows:The total Δp = housing Δph + (element Δpe x working viscosity/30).

Page 18: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

18/28/38P Series

Element Service

Pressure Drop Curves (cont.)

Parker HannifinFilter Division EuropeFDHB200UK. Section 15

120

38P-1 Empty Housing and High Collapse

38P-1 Elements

38P-2 High Collapse Elements

43.5

29.0

0

0 26 53 132

Flow (US GPM)

Flow (l/min)100 200 500400

0.0

Δp (b

ar)

20QH

1.0

2.0

3.0

0

0.5

1.5

2.5

106

14.5

Δp (P

SID

)

10QH

05QH

02QH

300

79

Empty Housing

159

600

43.5

29.0

0

0 26 53 132

Flow (US GPM)

Flow (l/min)100 200 500400

0.0

Δp (b

ar)

20QH

1.0

2.0

3.0

0

0.5

1.5

2.5

106

14.5

Δp (P

SID

)10QH

05QH

02QH

300

79 159

600

43.5

29.0

0

0 26 53 132

Flow (US GPM)

Flow (l/min)100 200 500400

0.0

Δp (b

ar)

20Q1.0

2.0

3.0

0

0.5

1.5

2.5

106

14.5

Δp (P

SID

)

10Q

05Q

02Q

300

79 159

600

38P-2 Elements

43.5

29.0

0

0 26 53 132

Flow (US GPM)

Flow (l/min)100 200 500400

0.0

Δp (b

ar)

20Q

1.0

2.0

3.0

0

0.5

1.5

2.5

106

14.5

Δp (P

SID

)

10Q

05Q

02Q

300

79 159

600

A. Stop the system’s power unit.B. Relieve any system pressure in the filter line.C. Drain the filter bowl if drain port option is provided.D. Rotate the bowl clockwise (left) and remove.E. Remove element by pulling downward with a

slight twisting motion and discard.F. Check bowl o-ring and anti-extrusion ring for

damage and replace if necessary.G. Lubricate element o-ring with system fluid and

locate element in filter head.H. Install bowl by rotating counter-clockwise (right)

and tighten to specified torque.18P – 22-27 Nm28P – 35-40 Nm38P – 80-95 Nm

I. Confirm there are no leaks after powering the system.

Head AssemblyElementBowlIndicatorsM3 – Visual auto reset; 2.5 barM3 – Visual auto reset; 5.0 barT1 – Electrical; 2.5 bar with

DIN 43650 ConnectorT1 – Electrical; 5.0 bar with

DIN 43650 ConnectorF1 – Electronic PNP; 2.5 bar with 4 LEDF2 – Electronic NPN; 2.5 bar with 4 LEDF1 – Electronic PNP; 5.0 bar with 4 LEDF2 – Electronic NPN; 5.0 bar with 4 LEDBowl SealBowl Anti-extrusion RingSeal KitsSeal kit 18P (std) – NitrileSeal kit 18P (F3) – FluoroelastomerSeal kit 28P (std) – NitrileSeal kit 28P (F3) – FluoroelastomerSeal kit 38P (std) – NitrileSeal Kit 38P (F3) – Fluoroelastomer

see table on next page

S04350S04351S04352S04353S04354S04355

123

4

5

67

Index Description Part number

Parts List

Page 19: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

6

7

2

1

5 4

High pressure filters

Element Service (cont.)

121

Replacement element part numbers

18P-1G04242G04243G04244G04245G04290G04291G04292G04293

18P-2G04250G04251G04252G04253G04298G04299G04300G04301

28P-1G04258G04259G04260G04261G04306G04307G04308G04309

28P-2G04266G04267G04268G04269G04314G04315G04316G04317

38P-1G04274G04275G04276G04277G04322G04323G04324G04325

38P-2G04282G04283G04284G04285G04330G04331G04332G04333

Model02Q05Q10Q20Q

02QH05QH10QH20QH

Elements with Nitrile seals

18P-1G04236G04237G04238G04239G04294G04295G04296G04297

18P-2G04254G04255G04256G04257G04202G04203G04304G04305

28P-1G04262G04263G04264G04265G04310G04311G04312G04313

28P-2G04270G04271G04272G04273G04318G04319G04320G04321

38P-1G04278G04279G04280G04281G04326G04327G04328G04329

38P-2G04286G04287G04288G04289G04334G04335G04336G04337

Model02Q05Q10Q20Q

02QH05QH10QH20QH

Elements with Fluoroelastomer seals

Ordering Information

Note: Filter assemblies ordered from the product configurator on the next page are on extended lead times. Where possible, please make your selection from the table above.

Part number

18P110QBT1MG12118P110QBM3MG12118P120QBT1MG12118P120QBM3MG12118P210QBT1MG12118P210QBM3MG12118P220QBT1MG12118P220QBM3MG12128P110QBT1MG16128P110QBM3MG16128P120QBT1MG16128P120QBM3MG16128P210QBT1MG16128P210QBM3MG16138P110QBT1MG20138P110QBM3MG20138P120QBT1MG20138P120QBM3MG20138P210QBT1MG20138P210QBM3MG20138P220QBT1MG20138P220QBM3MG201

Supercedes

18P-1-10Q-TW6-98-B2B2-118P-1-10Q-M2-98-B2B2-118P-1-20Q-TW6-98-B2B2-118P-1-20Q-M2-98-B2B2-118P-2-10Q-TW6-98-B2B2-118P-2-10Q-M2-98-B2B2-118P-2-20Q-TW6-98-B2B2-118P-2-20Q-M2-98-B2B2-128P-1-10Q-TW6-98-C2C2-128P-1-10Q-M2-98-C2C2-128P-1-20Q-TW6-98-C2C2-128P-1-20Q-M2-98-C2C2-128P-2-10Q-TW6-98-C2C2-128P-2-10Q-M2-98-C2C2-138P-1-10Q-TW6-98-D2D2-138P-1-10Q-M2-98-D2D2-138P-1-20Q-TW6-98-D2D2-138P-1-20Q-M2-98-D2D2-138P-2-10Q-TW6-98-D2D2-138P-2-10Q-M2-98-D2D2-138P-2-20Q-TW6-98-D2D2-138P-2-20Q-M2-98-D2D2-1

Flow(l/min)

8080

100100130130150150120120150150250250340340420420560560700700

Modelnumber

18P18P18P18P18P18P18P18P28P28P28P28P28P28P38P38P38P38P38P38P38P38P

Elementlength

Length 1Length 1Length 1Length 1Length 2Length 2Length 2Length 2Length 1Length 1Length 1Length 1Length 2Length 2Length 1Length 1Length 1Length 1Length 2Length 2Length 2Length 2

Mediarating (μ)

10102020101020201010202010101010202010102020

Seals

NitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrile

Indicator

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

Bypasssettings

7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar

Replacementelements

G04244G04244G04245G04245G04252G04252G04253G04253G04260G04260G04261G04261G04268G04268G04276G04276G04277G04277G04284G04284G04285G04285

Ports

G3/4"G3/4"G3/4"G3/4"G3/4"G3/4"G3/4"G3/4"G1"G1"G1"G1"G1"G1"

G11/4"G11/4"G11/4"G11/4"G11/4"G11/4"G11/4"G11/4"

Standard products table

Page 20: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

Parker HannifinFilter Division EuropeFDHB200UK. Section 15

122

High Pressure Filters

18/28/38P SeriesOrdering Information (cont.)

Product configuratorBox 1

Code12

LengthLength 1Length 2

Filter typeBox 2

38PBox 2

1Box 3

10QBox 4

BBox 5

M3Box 6

MBox 7

G20Box 8

1

CodeBV

Seal materialNitrileFluoroelastomer

Seal typeBox 4

Bypass valve3.5 bar7.0 barNo bypassNo bypass

Bypass and indicator settingsIndicator

2.5 bar5.0 bar5.0 bar

No indicator+ Box 8: code 2+ Box 8: code 2

CodeKMMX

Box 6

CodeN

M3T1PF1F2F3F4

No indicator portVisual indicatorElectrical indicatorPlugged with steel plugElectronic 4 LED, PNP, N.O.Electronic 4 LED, NPN, N.O.Electronic 4 LED, PNP, N.C.Electronic 4 LED, NPN, N.C.

IndicatorBox 5

Code12

OptionsStandardNo bypass

OptionsBox 8

Code18P28P38P

ModelSmall size high pressure filter, T-portMedium size high pressure filter, T-portLarge size high pressure filter, T-port

CodeBox 1

CodeG12S12M27H12F12G16S16M33H16F16G20G24S20S24M42M48H20F20

Ports18P: Thread G 3/4

Thread SAE 12Thread M27, ISO 6149SAE flange 3/4" 6000-MSAE flange 3/4" 6000

28P: Thread G 1 Thread SAE 16Thread M33, ISO 6149SAE flange 1" 6000-MSAE flange 1" 6000

38P: Thread G 1 1/4

Thread G 1 1/2

Thread SAE 20Thread SAE 24Thread M42, ISO 6149Thread M48, ISO 6149SAE flange 1 1/4" 6000-MSAE flange 1 1/4" 6000

Filter connectionBox 7

Filter model18P-118P-228P-128P-238P-138P-2

Nominal flow (I/min) at viscosity 30 cSt02Q357080

140140320

05Q60110100200220440

10Q80

130120250340560

20Q100150150300420700

Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.

When filter includes a bypass valve but not an indicator,code denotes bypass setting.

Item is standardItem is standard with “green” optionsItem is semi standardItem is non standard

123123123123

Highlights Key (Denotes part number availability)

Note: Standard items are in stock, semi standard items are available within four weeks

Box 3

Element media

Microglass III elementHigh collapse element

20μ media20Q

20QH

10μ media10Q

10QH

5μ media05Q

05QH

2μ media02Q

02QH

Glass fibre

Degree of filtration

Average filtration beta ratio ß (ISO 16889) / particle size μm [c]

% efficiency, based on the above beta ratio (ßx)ßx(c)=2

50.0%N/AN/AN/A6

Degree of filtrationCode

ßx(c)=10

90.0%N/AN/A611

ßx(c)=75

98.7%N/A4.58.517

ßx(c)=100

99.0%N/A5918

ßx(c)=200

99.5%N/A61020

ßx(c)=1000

99.9%4.571222

02Q05Q10Q20Q

DisposableMicroglass III

02QH05QH10QH20QH

High collapseelement

Page 21: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

70/70 Eco SeriesMAX 450 I/min - 420 bar

High pressure filters

FEATURING

123

Page 22: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

70/70 Eco Series

Typical Applications

Forestry equipmentIndustrial power unitsPulp and paperPort handling equipmentMining and quarryingequipment

The Parker Filtration 70/70 Eco Series High Pressure Filters.High quality 420 bar in-line pressure filters designed tooffer high levels of protection at flows up to 450 l/min.

Dirt sensitive systems can be protected with confidenceusing the 70 Series high pressure filters.

The 70 Series also available with environmentallyfriendly Ecoglass III elements.

Features & Benefits

Parker HannifinFilter Division EuropeFDHB200UK. Section 16

124

Features

Fatigue tested to full pressure rating

Several head options andconnection sizes

Several bowl lengths

Microglass III replacement elements

Coreless Ecoglass III replacementelements

Visual, electrical and electronicindicators available

Advantages

Strong and robust housing for heavy dutyapplications

Easy mounting

Optimised sizing

Multi-layered design produced high capacity andefficiency

Wire support reduces pleat bunching, keepsperformance consistent

No metal content in elementReduced overall weight of 50%Easy compaction of used elementsEco adaptors available

Check element condition at a glance

Right style for the application

Benefits

Reliable and continuous operation bothin mobile and industrial applications

Reduced space and pipingRight filter for each application

Efficient filtration

Great performance valueReliable performance throughoutelement lifeReduces downtime, maximises element lifeEnvironmentally friendly disposal byincinerationLower element replacement costsLower disposal costsRetrofit coreless design to housingsalready installed

Optimise element life, prevent bypassing

Matches your system electricalconnections

Page 23: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High pressure filters

Specification

Pressure ratings:Maximum allowable operating pressure 420 bar. Filter housing pressure pulse fatigue tested: 106 pulses 0 - 414 bar.

Connections:Threads G1, G11/4, G11/2 (ISO 228/1).or flanges 11/4" SAE 3000-M, 11/2" SAE 3000-M, 11/4" SAE 6000-M,11/2" SAE 6000-M.

Filter housing:Head material cast iron (GSI). Bowl material steel. Max torque 40 Nm.

Seal material:Nitrile or Fluoroelastomer.

Operating temperature range:- 20°C to +100°C.

Bypass valve:Opening pressure 3.5 bar.

Filter element:Degree of filtration:Determined by Multipass-test according to ISO 16889, see Box 3 inthe product configurator.

Flow fatigue characteristics:Filter media is supported so that the optimal fatigue life is achieved(ISO 3724).

Microglass III:Supported with epoxy coated metal wire mesh, end cap materialreinforced composite and metal inner core. Collapse rating 20 bar (ISO 2941).

Ecoglass III:Supported with plastic net, end cap material reinforced composite. No metal parts.Collapse rating 10 bar (ISO 2941).Filter element can only be used together with reusable FEA Eco-adapter. Note: Ecoglass III contributes to ISO 14001 quality.

High collapse elements:(To be used when no bypass function in filter housing).Microglass III media supported with epoxy coated metal wire mesh on upstream and stainless steel on downstream, end cap materialsteel. Strong metal inner core. Collapse rating 210 bar (ISO 2941).

Indicator options:Indicating differential pressure: 2.5 ± 0.2 bar or 7.0 ± 0.5 bar.2.5 bar indicators to be used with 3.5 bar bypass valve and 7.0 bar indicators with no bypass function.- visual M3.- electrical T1.- electronic F1(PNP).- electronic F2(NPN).For indicator details see catalogue section 6.

Fluid compatibility:Suitable for use with mineral and vegetable oils, and some synthetic oils. For other fluids, please consult Parker Filtration.

125

Page 24: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

70B 70T 70L

62(2.44)

129(5.08)

60

B

41 HEX(1.61)

A

Out

In

D

137(5.39)

43(1.69)

M10 depth 20 (0.78)

Note: Nofasteningholes withSAE flangeoption

Out In

D D

Option (for all models)plug G1/4

Optionplug M12x1.5

M10 depth 10

Vent port

Δp indicator

30(1.18)

140

Internal dia. 32/external dia. 41

4 mounting holes 21 dia.

Outlet

O-ring size 220

52(2.04)

190(7.48)

58(2.28)

B

Inlet

60(2.36) 41 HEX

(1.61)

137(5.39)

144

(5.6

7)

100

(3.9

4)

56(2.20)

41 HEX

D

Ø103(4.05)

142

(5.6

0)

mm(inches)

953.74

43(1.69)

High Pressure Filters

70/70 Eco SeriesSpecification

Parker HannifinFilter Division EuropeFDHB200UK. Section 16

126

Length 1

Length 2

Length 3

Length 4

116 (4.57)

208 (8.19)

329 (12.95)

428 (16.85)

249 (9.80)

342 (13.46)

462 (18.19)

562 (22.12)

295 (11.61)

390 (15.35)

510 (20.08)

610 (24.01)

235 (9.25)

330 (13.00)

450 (17.72)

550 (21.65)

420 bar

350 bar

G1, G11/4 or G11/2

Flange 11/2 SAE 3000-MFlange 11/4 SAE 3000-MFlange 11/2 SAE 6000-MFlange 11/4 SAE 6000-M

Type A B B B Max working Portpressure D70B 70L70T

Type 70T 70L 70BLength 1 14 10.5 11.5Length 2 16.5 13 14Length 3 19 15.5 16.5Length 4 22 18.5 19.5

Weights (kg)89

(3.50)

75(2

.95)

60

129(5.08)

70

B

Page 25: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High pressure filters

Pressure Drop Curves

127

70-1 Elements with Microglass III

70-3 Elements with Microglass III

70 Series Empty Housing

70-2 Elements with Microglass III

70-4 Elements with Microglass III

With 3.5 bar bypass the recommended initial pressure drop is max 1.2 bar.If the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows:The total Δp = housing Δph + (element Δpe x working viscosity/30).

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

02Q

Δp (b

ar)

05Q 10Q 20Q

Δp (P

SID

)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

02Q

Δp (b

ar)

05Q

10Q

20Q

Δp (P

SID

)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

02Q

Δp (b

ar)

05Q

10Q

20Q Δp (P

SID

)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

D

E

A

B C

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

Δp (b

ar)

0

0.2

0.4

1.4

1.2

1

0.6

0.8

Flow (US GPM)

0 53 79 106 13226

Δp (P

SID

)

0

2.9

5.8

11.6

17.4

20.3

14.5

11992663913

8.7

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

02Q

Δp (b

ar) 05Q

10Q

20Q Δp (P

SID

)

Flow (US GPM)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.30 13 26 39 53 66 79 92 106 119 132

A: 70T with G16 connectionsB: 70T with G20 connections

70L with G16 connectionsC: 70T with G20 connections

70BD: 70T with G24 connectionsE: 70L with G24 connections

Page 26: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

70/70 Eco SeriesPressure Drop Curves (cont.)

Parker HannifinFilter Division EuropeFDHB200UK. Section 16

128

70-1 Elements with Ecoglass III

70-3 Elements with Ecoglass III 70-4 Elements with Ecoglass III

70-2 Elements with Ecoglass III

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

02QE

Δp (b

ar)

05QE

10QE20QE

Δp (P

SID

)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

02QE

Δp (b

ar)

05QE10QE

20QE

Δp (P

SID

)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

02QE

Δp (b

ar) 05QE

10QE

20QE

Δp (P

SID

)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500

Flow (l/min)

02QE

Δp (b

ar) 05QE

10QE

20QE

Δp (P

SID

)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

Page 27: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High pressure filters

Ordering Information

129

Note: Filter assemblies ordered from the product configurator on next page are on extended lead times. Where possible, please make your selection from the table above.

Part number

70L110QBPKG16170L120QBPKG16170L210QBPKG20170L220QBPKG20170L310QBPKG24170L320QBPKG24170L410QBPKG24170L420QBPKG24170L110QEBPKG16170L120QEBPKG16170L210QEBPKG20170L220QEBPKG20170L310QEBPKG24170L320QEBPKG24170L410QEBPKG24170L420QEBPKG24170T110QBPKG16170T120QBPKG16170T210QBPKG20170T220QBPKG20170T310QBPKG24170T320QBPKG24170T410QBPKG24170T420QBPKG24170T110QEBPKG16170T120QEBPKG16170T210QEBPKG20170T220QEBPKG20170T310QEBPKG24170T320QEBPKG24170T410QEBPKG24170T420QEBPKG241

Supercedes

FF7005.Q010.BS35.GL16FF7005.Q020.BS35.GL16FF7006.Q010.BS35.GL20FF7006.Q020.BS35.GL20FF7007.Q010.BS35.GL24FF7007.Q020.BS35.GL24FF7008.Q010.BS35.GL24FF7008.Q020.BS35.GL24FF7005.QE10.BS35.GL16FF7005.QE20.BS35.GL16FF7006.QE10.BS35.GL20FF7006.QE20.BS35.GL20FF7007.QE10.BS35.GL24FF7007.QE20.BS35.GL24FF7008.QE10.BS35.GL24FF7008.QE20.BS35.GL24FF7005.Q010.BS35.GT16FF7005.Q020.BS35.GT16FF7006.Q010.BS35.GT20FF7006.Q020.BS35.GT20FF7007.Q010.BS35.GT24FF7007.Q020.BS35.GT24FF7008.Q010.BS35.GT24FF7008.Q020.BS35.GT24FF7005.QE10.BS35.GT16FF7005.QE20.BS35.GT16FF7006.QE10.BS35.GT20FF7006.QE20.BS35.GT20FF7007.QE10.BS35.GT24FF7007.QE20.BS35.GT24FF7008.QE10.BS35.GT24FF7008.QE20.BS35.GT24

Flow(l/min)

150230280300400430430450150230280300400430430450150200260280360380360380150200260280360380360380

Modelnumber

70L70L70L70L70L70L70L70L70L70L70L70L70L70L70L70L70T70T70T70T70T70T70T70T70T70T70T70T70T70T70T70T

Elementlength

11223344112233441122334411223344

Mediarating (μ)

1020102010201020102010201020102010201020102010201020102010201020

Seals

NitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrile

Indicator

PluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPluggedPlugged

Bypasssettings

3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar

Replacementelements

938773Q938774Q938777Q938778Q938781Q938782Q938785Q938786Q938789Q938790Q938793Q938794Q938797Q938798Q938801Q938802Q938773Q938774Q938777Q938778Q938781Q938782Q938785Q938786Q938789Q938790Q938793Q938794Q938797Q938798Q938801Q938802Q

Supercedes

FC7005.Q010.BKFC7005.Q020.BKFC7006.Q010.BKFC7006.Q020.BKFC7007.Q010.BKFC7007.Q020.BKFC7008.Q010.BKFC7008.Q020.BKFC7005.QE10.BKFC7005.QE20.BKFC7006.QE10.BKFC7006.QE20.BKFC7007.QE10.BKFC7007.QE20.BKFC7008.QE10.BKFC7008.QE20.BKFC7005.Q010.BKFC7005.Q020.BKFC7006.Q010.BKFC7006.Q020.BKFC7007.Q010.BKFC7007.Q020.BKFC7008.Q010.BKFC7008.Q020.BKFC7005.QE10.BKFC7005.QE20.BKFC7006.QE10.BKFC7006.QE20.BKFC7007.QE10.BKFC7007.QE20.BKFC7008.QE10.BKFC7008.QE20.BK

Ports

G1"G1"

G11/4"G11/4"G11/2"G11/2"G11/2"G11/2"G1"G1"

G11/4"G11/4"G11/2"G11/2"G11/2"G11/2"G1"G1"

G11/4"G11/4"G11/2"G11/2"G11/2"G11/2"G1"G1"

G11/4"G11/4"G11/2"G11/2"G11/2"G11/2"

Standard products table

Page 28: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Filters

70/70 Eco SeriesOrdering Information (cont.)

Parker HannifinFilter Division EuropeFDHB200UK. Section 16

130

Product configuratorBox 1

Code1234

LengthLength 1Length 2Length 3Length 4

Filter typeBox 2

70LBox 2

3Box 3

10QBox 4

BBox 5

M3Box 6

KBox 7

G24Box 8

1

CodeBV

Seal materialNitrileFluoroelastomer

Seal typeBox 4

Bypass valve3.5 barNo bypassNo bypass

Bypass and indicator settingsIndicator

2.5 bar7.0 bar

No indicator (P)+ Box 8: code 2+ Box 8: code 2

CodeKNX

Box 6

CodeP

M3T1F1F2F3F4

Plugged with steel plugVisual indicatorElectrical indicatorElectronic 4 LED, PNP, N.O.Electronic 4 LED, NPN, N.O.Electronic 4 LED, PNP, N.C.Electronic 4 LED, NPN, N.C.

IndicatorBox 5

Code1268

OptionsStandardNo bypass70T: side indicator ports70T: options 2 + 6

OptionsBox 8

Code70L70T70B

ModelHigh pressure filter with L-portHigh pressure filter with T-portHigh pressure filter with side manifold mounting

CodeBox 1

Options 6 and 8: in 70T model there is an optionfor 2 x indicator ports on filter outlet flange(standard indicator port not machined)P: both side indicator ports plugged with steel plugM3 or other indicator chosen: right side (in flowdirection) port plugged with a plastic plug, left witha steel plug

Note: When using Ecoglass III elements reusable Eco-adaptor is required

CodeG16G20G24R20R24H20H24X32

ConnectionsThread G 1Thread G 1 1/4

Thread G 1 1/2

SAE flange 1 1/4" 3000-MSAE flange 1 1/2" 3000-MSAE flange 1 1/4" 6000-MSAE flange 1 1/2" 6000-MSide manifold (70B only)

Filter connectionLength 1

SSxxxxxx

Length 2SSSxxxxx

Length 3xSSxxxxx

Length 4xSSxxxxx

Box 7

Availability: S = standard productx = non-standard, ask for availability

Filter lengthLength 1

Length 2

Length 3

Length 4

Nominal flow (I/min) at viscosity 30 cSt

Media02Q/02QE05Q/05QE10Q/10QE20Q/20QE02Q/02QE05Q/05QE10Q/10QE20Q/20QE02Q/02QE05Q/05QE10Q/10QE20Q/20QE02Q/02QE05Q/05QE10Q/10QE20Q/20QE

G16 T-port80120150200160180220240200220240250220230250260

G16 L-port &G20 T-port

80120150230160200260280220250280300250260280300

G20 L-port &Side manifold

80120150230160200280300220280300320270300330350

G24 T-port80120150230160200300330220280350380270330360380

G24 L-port80

120150230160200320350220280400430270330430450

Media02Q05Q10Q20Q

02QE05QE10QE20QE02QH05QH10QH20QH

Replacement elements with nitrile sealsLength 1938771Q938772Q938773Q938774Q938787Q938788Q938789Q938790Q938803Q938804Q938805Q938806Q

Length 2938775Q938776Q938777Q938778Q938791Q938792Q938793Q938794Q938807Q938808Q938809Q938810Q

Length 3938779Q938780Q938781Q938782Q938795Q938796Q938797Q938798Q938811Q938812Q938813Q938814Q

Length 4938783Q938784Q938785Q938786Q938799Q938800Q938801Q938802Q938815Q938816Q938817Q938818Q

Note 1: Part numbers featured with boldhighlighted codes will ensure a ‘standard’product selection.Note 2: Alternate displayed part numberselection will require you to contact ParkerFiltration for availability.

When filter includes a bypass valve but not an indicator,code denotes bypass setting.

Item is standardItem is standard with “green” optionsItem is semi standardItem is non standard

123123123123

Highlights Key (Denotes part number availability)

Note: Standard items are in stock, semi standard items are available withinfour weeks

Box 3

Element media

Microglass III elementEcoglass III elementHigh collapse element

20μ media20Q

20QE20QH

10μ media10Q

10QE10QH

5μ media05Q

05QE05QH

2μ media02Q

02QE02QH

Glass fibre

Degree of filtration

Average filtration beta ratio ß (ISO 16889) / particle size μm [c]

% efficiency, based on the above beta ratio (ßx)ßx(c)=2

50.0%N/AN/AN/A6

Degree of filtrationCode

ßx(c)=10

90.0%N/AN/A611

ßx(c)=75

98.7%N/A4.58.517

ßx(c)=100

99.0%N/A5918

ßx(c)=200

99.5%N/A61020

ßx(c)=1000

99.9%4.571222

02Q05Q10Q20Q

DisposableMicroglass III

02QE05QE10QE20QE

Metal freeEcoglass III

02QH05QH10QH20QH

High collapseelement

Page 29: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Duplex Filters

22PD/32PD SeriesMAX 260 I/min - 210 bar

High pressure filters131

Page 30: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Duplex Filters

22PD/32PD Series

Typical Applications

Ship steering systemsContinuous operationindustrial systemsHigh flow flushing systems

The Parker Filtration 22PD/32PD SeriesHigh Pressure Duplex Filters.Specially designed to offer continuous operation,even during element change.

A changeover valve operates on the upstream sideof the filter, ensuring a contamination free system.

Features & Benefits

Parker HannifinFilter Division EuropeFDHB200UK. Section 17

132

Features

Duplex design

Integrated balancing valve

Vent ports

Microglass III replacement elements

Visual, electrical and electronicindicators available

Advantages

Element service possible during operation

No external piping required

Purges all trapped air in filter

Multi-layered design produced high capacity and efficiency

Wire support reduces pleat bunching, keepsperformance consistent

Check element condition at a glance

Right style for the application

Benefits

Allows to keep machine running withfull contamination protection

Safety and reliability

Get the maximum performance fromthe elements

Prevents a "flabby" system

Great performance value

Reliable performance throughoutelement life

Reduces downtime, maximises element life

Optimises element life, preventsbypassing

Matches your system electricalconnections

Page 31: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High pressure filters

Specification

Pressure ratings:Maximum allowable operating pressure 210 bar.Filter housing pressure pulse fatigue tested: 106 cycles 210 bar.Connections:Inlet and outlet connections are threaded.Connection style Model

22PD 32PDBSPF(G) 1” 11/4”Flange SAE 3000-M 11/4” 11/2”*3000-M is a SAE style with appropriate metric fixing threads.Filter housing:Head material cast iron (GSI).Bowl material steel.Seal material:Nitrile or Fluoroelastomer.Operating temperature range:-20°C to +100°C.Bypass valve:Opening pressure 3.5 barFilter element:Degree of filtration:Determined by multipass-test according to ISO 16889, see Box 3 in the product configurator.

Flow fatigue characteristics:Filter media is supported so that the optimal fatigue life is achieved (ISO 3724).Microglass III:Supported with epoxy coated metal wire mesh, end cap materialreinforced composite and metal inner core. Collapse rating 20 bar (ISO 2941).High collapse elements:(to be used when no bypass function in filter housing).Microglass III media supported with epoxy coated metal wire mesh onupstream and stainless steel on downstream, end cap material steel.Strong metal inner core. Collapse rating 210 bar (ISO 2941).Indicator options:Indicating differential pressure: 2.5 ± 0.2 bar.- visual M3.- electrical T1.- electronic F1(PNP).- electronic F2(NPN).For indicator details see catalogue section 6.Weights (kg):Model Length 1 Length 222PD 22 2732PD 44 50Fluid compatibility:Suitable for use with mineral and vegetable oils, and some synthetic oils. For other fluids, please consult Parker Filtration.

133

240(9.45)306

(12.05)

35(1.38)

42(1.65)

92(3.62)130

(5.12)

18(0.71)

20(0.79)

55(2.16)

78(3.07)

150(5.91)170

(6.69)

150(5.90)165

(6.49)

96(3.70)120

(4.72)

192(7.56)240

(9.45)

60(2.36)

75(2.95)

30(1.18)

36(1.42)

59(2.32)

70(2.75)

22PD-122-PD-232PD-132PD-2

236 (9.29)345 (13.58)317 (12.48)437 (17.20)

Dimensions mm (inches)

Model A B C D E F G H I J K L M N

Flange face detail

L

K

Both 22PD & 32PDM12x1.72 pitch

x20 deep

M

30.75Ø

38Ø

A

BIn Out

C

Hexagon22PD

24 A/F32PD

36 A/F

Bowlremoval100mm(3.93)

mm(inches)

N

D

E

F

JG

H

I

2 bleedholesG1/8

Bleed valveBalance valve

Indicator location

Changeoverhandle

40 mounting holes22PD: M8x1.2 pitchx12 deep32PD: M10x1.5 pitchx15 deep

Page 32: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Duplex Filters

22PD/32PD SeriesPressure Drop Curves

The recommended level of initial pressure drop is max. 1.2 bar.If the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows:Δp = (Δp30 x viscosity of medium used) / 30 cSt. The total Δp = housing Δph + (element Δpe x working viscosity/30).

Parker HannifinFilter Division EuropeFDHB200UK. Section 17

134

0.0

0.5

1.0

1.5

2.0

0 50 100 150 200 250 300 350 400

Flow (l/min)

Δp (b

ar)

22PD

Flow (US GPM)

0 39 92 106

Δp (P

SID

)

0

7.3

14.5

21.8

29.013 26 53 7966

32PD

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0 50 100 150 200 250 300 350 400

Flow (l/min)

Δp (b

ar) Cracking

Pressure

Flow (US GPM)

0 39 92 106

Δp (P

SID

)

0

7.3

14.5

21.8

29.0

36.3

43.513 26 53 7966

0.0

0.5

1.0

1.5

2.0

2.5

3.0

Flow (l/min)

Δp (b

ar)

02Q

Flow (US GPM)

Δp (P

SID

)

0

7.3

14.5

21.8

29.0

36.3

43.5

05Q

10Q

20Q

0 13 26 66

50 100 2502000

53

150 300

39 79

0.0

0.5

1.0

1.5

2.0

2.5

3.0

Flow (l/min)

Δp (b

ar)

02Q

Flow (US GPM)

Δp (P

SID

)

0

7.3

14.5

21.8

29.0

36.3

43.5

05Q

10Q

20Q

0 13 26 66

50 100 2502000

53

150 300

39 79

22PD/32PD Empty Housing

22PD-1 Elements

22PD/32PD Bypass Valve

22PD-2 Elements

0.0

0.5

1.0

1.5

2.0

2.5

3.0

Flow (l/min)

Δp (b

ar)

02Q

Flow (US GPM)

Δp (P

SID

)

0

7.3

14.5

21.8

29.0

36.3

43.5

05Q

10Q20Q

0 13 26 66

50 100 2502000

53

150 300

39 79

0.0

0.5

1.0

1.5

2.0

2.5

3.0

Flow (l/min)

Δp (b

ar) 02Q

Flow (US GPM)

Δp (P

SID

)

0

7.3

14.5

21.8

29.0

36.3

43.5

05Q

10Q

20Q

0 13 26 66

50 100 2502000

53

150 300

39 79

32PD-1 Elements 32PD-2 Elements

Page 33: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High pressure filters135

0.0

0.5

1.0

1.5

2.0

2.5

3.0

Flow (l/min)

Δp (b

ar)

02 QH

Flow (US GPM)

Δp (P

SID

)

0

7.3

14.5

21.8

29.0

36.3

43.5

05 QH 10 QH

20 QH

0 13 26 66

50 100 2502000

53

150 300

39 79

0.0

0.5

1.0

1.5

2.0

2.5

3.0

Flow (l/min)Δp

(bar

)

02 QH

Flow (US GPM)

Δp (P

SID

)

0

7.3

14.5

21.8

29.0

36.3

43.5

05 QH

10 QH

20 QH

0 13 26 66

50 100 2502000

53

150 300

39 79

0.0

0.5

1.0

1.5

2.0

2.5

3.0

Flow (l/min)

Δp (b

ar)

02 QH

Flow (US GPM)

Δp (P

SID

)

0

7.3

14.5

21.8

29.0

36.3

43.5

05 QH

10 QH

20 QH

0 13 26 66

50 100 2502000

53

150 300

39 79

0.0

0.5

1.0

1.5

2.0

2.5

3.0

Flow (l/min)

Δp (b

ar)

02 QH

Flow (US GPM)

Δp (P

SID

)

0

7.3

14.5

21.8

29.0

36.3

43.5

05 QH

10 QH

20 QH

0 13 26 66

50 100 2502000

53

150 300

39 79

22PD-1 High Collapse Elements

32PD-1 High Collapse Elements

22PD-2 High Collapse Elements

32PD-2 High Collapse Elements

Ordering Information

Note: Filter assemblies ordered from the product configurator on the next page are on extended lead times. Where possible, please make your selection from the table above.

Part number

22PD210QBM3KG16122PD210QBT1KG16122PD220QBM3KG16122PD220QBT1KG16132PD210QBM3KG20132PD210QBT1KG20132PD220QBM3KG20132PD220QBT1KG201

Supercedes

0-22-PD-2-10Q-V-50-C-10-22-PD-2-10Q-TW3-50-C-10-22-PD-2-20Q-V-50-C-10-22-PD-2-20Q-TW3-50-C-10-32-PD-2-10Q-V-50-D-10-32-PD-2-10Q-TW3-50-D-10-32-PD-2-20Q-V-50-D-10-32-PD-2-20Q-TW3-50-D-1

Flow(l/min)

120120140140240240260260

Modelnumber

22PD22PD22PD22PD32PD32PD32PD32PD

Elementlength

Length 2Length 2Length 2Length 2Length 2Length 2Length 2Length 2

Mediarating (μ)

1010202010102020

Seals

NitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrile

Indicator

VisualElectrical

VisualElectrical

VisualElectrical

VisualElectrical

Bypasssettings

3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar

Replacementelements

G01315QG01315QG01938QG01938QG01098QG01098QG01954QG01954Q

Ports

G1"G1"G1"G1"

G11/4"G11/4"G11/4"G11/4"

Standard products table

Page 34: High Pressure Filters 15P/30P Series - H & P Servicesparkerdenisonpk.com/hydraulic_filtration/FDHB200UK_high_filters.pdf · High Pressure Filters 15P/30P Series Features & Benefits

High Pressure Duplex Filters

22PD/32PD SeriesOrdering Information (cont.)

Parker HannifinFilter Division EuropeFDHB200UK. Section 17

136

Product configuratorBox 1

Code12

LengthLength 1Length 2

Filter typeBox 2

22PDBox 2

2Box 3

10QBox 4

BBox 5

M3Box 6

KBox 7

G16Box 8

1

CodeBV

Seal materialNitrileFluoroelastomer

Seal typeBox 4

Bypass valve3.5 barNo bypassNo bypass

Bypass and indicator settingsIndicator

2.5 bar5.0 bar

No indicator+ Box 8: code 2+ Box 8: code 2

CodeKMX

Box 6

CodeM3T1PNF1F2F3F4

Visual indicatorElectrical indicatorPlugged with steel plugNo indicator portElectronic 4 LED, PNP, N.O.Electronic 4 LED, NPN, N.O.Electronic 4 LED, PNP, N.C.Electronic 4 LED, NPN, N.C.

IndicatorBox 5

Code12

OptionsStandardNo bypass

OptionsBox 8

Code22PD32PD

ModelSmall high pressure duplex filterLarge high pressure duplex filter

CodeBox 1

Note 1: Part numbers featured with bold highlighted codeswill ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection willrequire you to contact Parker Filtration for availability.

CodeG16R20G20R24

Ports22PD: Thread G 1

SAE flange 1 1/4" 3000-M32PD: Thread G 1 1/4

SAE flange 1 1/2" 3000-M

Filter connectionBox 7

Media02Q05Q10Q20Q

02QH05QH10QH20QH

Replacement elements with nitrile seals22PD-1

G01282QG02721QG01281QG01930QG01442QG03737QG01441QG01932Q

22PD-2G01316QG02724QG01315QG01938QG01448QG03738QG01447QG01940Q

32PD-1G01069QG02567QG01068QG01946QG01454QG03739QG01453QG01948Q

32PD-2G01099QG02727QG01098QG01954QG01460QG03740QG01459QG01956Q

Media02Q05Q10Q20Q

02QH05QH10QH20QH

Replacement elements with fluoroelastomer seals22PD-1

G01302QG02723QG01301QG01934QG01446QG04235QG01445QG01935Q

22PD-2G01336QG02726QG01335QG01942QG01452QG04236QG01451QG01943Q

32PD-1G01089QG02569QG01088QG01950QG01458QG04237QG01457QG01951Q

32PD-2G01119QG02729QG01118QG01958QG01464QG04238QG01463QG01959Q

Filter model22PD-122PD-232PD-132PD-2

Nominal flow (I/min) at viscosity 30 cSt02Q70

100100180

05Q80

110150210

10Q100120210240

20Q120140230260

Filter model22PD32PD

Seal kitsNitrile

S04233S02373

FluoroelastomerS04234S02375

When filter includes a bypass valve but not an indicator,code denotes bypass setting.

Item is standardItem is standard with “green” optionsItem is semi standardItem is non standard

123123123123

Highlights Key (Denotes part number availability)

Note: Standard items are in stock, semi standard items are available within four weeks

Box 3

Element media

Microglass III elementHigh collapse element

20μ media20Q

20QH

10μ media10Q

10QH

5μ media05Q

05QH

2μ media02Q

02QH

Glass fibre

Degree of filtration

Average filtration beta ratio ß (ISO 16889) / particle size μm [c]

% efficiency, based on the above beta ratio (ßx)ßx(c)=2

50.0%N/AN/AN/A6

Degree of filtrationCode

ßx(c)=10

90.0%N/AN/A611

ßx(c)=75

98.7%N/A4.58.517

ßx(c)=100

99.0%N/A5918

ßx(c)=200

99.5%N/A61020

ßx(c)=1000

99.9%4.571222

02Q05Q10Q20Q

DisposableMicroglass III

02QH05QH10QH20QH

High collapseelement