HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume...

25
HIGH PRECISION TERMITE CONTROL BASF Professional & Specialty Solutions FREDER MEDINA, Kenneth S. Brown, Jeff D. Vannoy, Bob Hickman, Bob Davis, Kyle Jordan, Jason Meyers, Matt Spears, Judy Fersch, Amy Dugger-Ronyak, Anil Menon, Richard Warriner, Jim Cink, John Paddock, and Joe Schuh. Email: [email protected] Cell: 919-475-9922 5/18/2016

Transcript of HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume...

Page 1: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

HIGH PRECISION TERMITE CONTROL

BASF Professional & Specialty Solutions

FREDER MEDINA, Kenneth S. Brown, Jeff D. Vannoy, Bob Hickman, Bob Davis,

Kyle Jordan, Jason Meyers, Matt Spears, Judy Fersch, Amy Dugger-Ronyak, Anil Menon, Richard Warriner,

Jim Cink, John Paddock, and Joe Schuh.

● Email: [email protected] ● Cell: 919-475-99225/18/2016

Page 2: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Termidor® Timeline

2High Precision Termite Control5/18/2016

At BASF, innovation plays an important role and provides Pest Management Professionals (PMPs) with…

…the most advance termite treatment products and tools.

Page 3: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Challenges of termite treatments

Since Termidor® first US registration in 2000 until today, more than six million homes have been successfully treated with our product. However, the efficacy of current control methods relies on a methodology that

involves digging trenches to establish continuous treatment zones around the foundation of the structure.

3High Precision Termite Control5/18/2016

Page 4: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Standard Application MethodDigging trenches to establish continuous treatment zones

Left: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench at2 gal/10 ln.ft.

4High Precision Termite Control5/18/2016

Preventive Pest Control technician using a flow meter.

Page 5: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Challenges of termite treatments

It is extremely difficult to create and maintain uniform horizontal and vertical treatment zones. Although there are many variables that can affect

the efficacy of termite treatments, it is critical to makeuniform and precise applications.

5High Precision Termite Control5/18/2016

Page 6: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Challenges of termite treatments

6High Precision Termite Control5/18/2016

Earth

gra

vity

Terrain slope

Product concentration

LowLow Low LowHigh High High High

Page 7: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Soil propertiesParticle size, water, microcapilarity, air, and organic matter content…

Soil Content (%)

Soil TypesSand Loam Clay

Sand 80-100 25-50 0-45Silt 0-10 30-50 0-45

Clay 0-10 10-30 50-100

12 in

Page 8: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Challenges of termite treatments

With our latest innovations,Termidor® H•P High Precision Termiticide

Termidor® H•P High Precision Injection System,

PMPs are able to inject Termidor® directly into the soil withunrivaled accuracy, precision, minimum disruption to

landscape, and less water consumption.

8High Precision Termite Control5/18/2016

Page 9: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

It is all about precision:

Cellular data transfer from a mobile device (cell phone, tablet, or Ipad™)

Controlled from an onboard computer.

Online and real-time reports

Bluetooth communication

Global Positioning (GPS)Coordinates can be plugged into google earth.

The Future of Termite Treatment

1st Treatment in Phoenix, AZ. Nov 20th 2013

Page 10: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

An evolving technology…

10High Precision Termite Control5/18/2016

Base Unit

PID (Precision Injection Device)

Page 11: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

An evolving technology…Termidor® H•P High Precision Injection System

11High Precision Termite Control5/18/2016

Base UnitWeight: 265 lbs

L45” x W18.5” x H36”

Treatment hosewith electric reel

75-80 lbsL20” x W26” x H20”

PID38 lbs

Page 12: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Termidor® H•P High Precision Injection System

125/11/2017

Mounting options used by PMPs.120 units right now in USA… with

about 90 different PMPs. Info: changes daily.

Intl.: Japan, Australia, & Brazil.

Page 13: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

System ComponentsStandard Application vs. Hydraulic Trenching

300 ftTreatment

Hose

H2O

TermidorTermidor+H2O

Hydraulic Trenching (HT) Mode

Standard Application (SA) Mode

PID =

Page 14: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Communication Process

Base Unit

PID

Termidor®H•PDatabase & Website

WirelessNetwork

Termidor®H•PMobile App

GPS

PMP

Page 15: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Termidor® H•P Websitehttps://www.termidorhpdata.com

1. Assigned person (not a technician) must log in from office computer.

2. Create the work orders for the dayby entering the information. Home address, work order number, and total linear feet to be treated.

15High Precision Termite Control5/18/2016

Page 16: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Android Mobile App.Once a work order has been created in the office…

Log in to the mobile app from your android phone or tablet.

IMPORTANT:PID and Base Unit must be turned ON

Page 17: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Android Mobile App.Sending a new work order to the unit…

Page 18: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

OperationHydraulic Trenching (HT) Mode

HOME SCREEN WORK ORDER SCREEN

Page 19: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Soil SettingsHydraulic Trenching (HT) Mode

75% less water used

Page 20: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Mode SelectionHydraulic Trenching (HT) Mode

MODE SCREEN HT MODE SCREEN

Page 21: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

OperationStandard Application (SA) Mode

HT MODE SCREEN SA MODE SCREEN

Page 22: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Termidor®H•P High Precision

Page 23: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Android Mobile App.To complete a work order…

PID and Base Unit must be ON

NOTE: once a work order has been completed, the data from the base unit is collected by the PID, gathered by the Android Mobile App., and sent to the Termidor® H•Pwebsite. After completing a work order, all information is zeroed out and the unit is ready for a new work order.

Page 24: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

Time and Motion Study (Arizona 2014)Standard vs. Hydraulic Trenching.

13.75.7

0

27.5

12.25.4

41.2

17.9

5.4

0

10

20

30

40

50Se

cond

s / L

inea

r Foo

t TrenchingApplicationTotal Time

Treatment Time savedper linear foot

Time saved per treatment of 200 linear foot home

H•P vs SC 35.8 sec 119 min (~2 hrs)H•P vs HE 12.5 sec 41.7 min

Termidor® SC Termidor® HE Termidor® H•P

Page 25: HIGH PRECISION TERMITE CONTROL: Tony Hilskotter, Clark Pest Control technician, performing a volume displacement vs. time calibration (the bucket method). Center: Tony treating a trench

ADVANTAGESThe most efficient is also the most precise.

25High Precision Termite Control5/18/2016

* Under most conditions. ** As compared to standard liquid applications.

New technology that's revolutionizing the way

termites are treatedwith automated

treatmenttracking.

Stay confident with the time-tested strength

of Termidor®.

Advanced application technology cuts

water usageby 75%.*,**

Provides a more uniform treatment zone around

the structure.**

Considerable time savings with no trenching, no rodding, and minimal

disruption tolandscaping.

*,**

Precisely applies product where it's needed to protect the structure

with reducedexposure.