High Performance Concrete Building Design Insulating Concrete Forms – a solution to current and future Energy and Building Codes in North America
Kevin Davis Director of Sales
Quad-Lock Building Systems
![Page 2: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/2.jpg)
CICFI.org
A consortium operating under the auspices of the Ontario Ready Mix Association.
![Page 3: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/3.jpg)
Environmental Role of Buildings
FACT #1: Our buildings consume the largest percentage of our total energy use
Source: US Energy Information Agency
![Page 4: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/4.jpg)
Environmental Role of Buildings
FACT #2: The “Appetite for Energy” of our buildings is driven
50% by space heating & cooling demands
Source: US Energy Information Agency
Residential Building
![Page 5: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/5.jpg)
Current Residential Energy Code Adoption Status
![Page 6: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/6.jpg)
Can We Change Cultural Priorities?
Change a culture that is
focused on the glittering
amenities?
Change a culture that is
focused on “first-cost” vs
total cost of ownership?
Not very likely!
![Page 7: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/7.jpg)
The Secret Is In Our Name
“Insulating” “Concrete” “Forms”
Two layers of high value EPS insulation provide continuous thermal barrier
Reinforced concrete provides durable structure & protection of occupants
Lightweight EPS forms are easily shaped & adapted to architectural designs
![Page 8: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/8.jpg)
Two ICF Use-Categories:
• Two-sided ICFs
Vertical concrete structures Flat, pitched or tilt-up concrete structures
• One-sided ICFs
![Page 9: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/9.jpg)
Strategic use of 3 unique
qualities:
9
Zero Porosity
Concrete Air Barrier
High R-Value &
Unbroken Insulation
Layers
High Mass for
Thermal Storage
9
How do ICFs control heat gain/loss?
![Page 10: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/10.jpg)
ICF vs. Neighbors
![Page 11: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/11.jpg)
ICF vs. Neighbors
11
![Page 12: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/12.jpg)
ICF Progress in the Market
12
![Page 13: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/13.jpg)
Available Insulation Options
![Page 14: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/14.jpg)
ICF Complete Concrete Building Enclosure
Walls Floors
Roofs
14
© 2013 Quad-Lock Building Systems, Ltd
![Page 15: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/15.jpg)
Desired Characteristics of Building Shells
$$ Yes Yes
Desired Characteristics ** Code Mandated
Moisture Resistant**
Wind Resistant**
Seismic Resistant**
Thermal Continuity**
Fire Resistant**
Safe/Non-toxic**
Impact Resistant
Adaptable to Design &
Utilities
$$ $ Yes Yes
$ $$ $$ Yes
$$ Yes Yes
$$ $ Yes Yes
$ $$ $$ Yes
Yes Yes Yes Yes
Yes Yes
Wood
Frame
Steel
Frame
Conv.
Concrete
ICF
Concrete
15
![Page 16: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/16.jpg)
ICF/Concrete Wall Reinforcement
Prescriptive Designs
to 150 mph (all exposures)
IRC Prescriptive Designs
16
![Page 17: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/17.jpg)
Lateral Strength Comparison
Wood Frame
ICF & Concrete
Concrete % Advantage
Global Lateral Stiffness (lbs/in)
18,500 708,000 +3,827%
Load at First Major Damage (lbs)
3,500 8,500 +243%
Displacement at First Major Damage
(in) 0.51 0.06 +850%
Maximum Lateral Resistance (lbs)
4,553 34,254 +752%
Displacement at Max. Lateral Resist.
(in) 0.89 2.66 +299%
Test performed by PCA based on ASTM E564-95
17
![Page 18: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/18.jpg)
Relevant Codes and Standards: USA
International Residential Code • Chapters 3, 6 & 11
International Building Code • Chapters 16 & 19
International Energy Conservation
Code
ASCE 24-05 • Flood Resistant Design & Construction
ACI 318 • Building Requirements for Structural Concrete
18
![Page 19: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/19.jpg)
Relevant Codes and Standards: Canada
National Building Code of Canada or Provincial Codes • Parts 3, 4, 5 & 9
• Post-Disaster Category
CAN/CSA A23.3
• Design of Concrete Structures
ASCE 24-05 • Flood Resistant Design & Construction
19
2011 National Model Energy Code for
Buildings
ASCE 7 • Minimum Design Loads for Buildings
![Page 20: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/20.jpg)
Disaster Resistant ICF/Concrete Designs
20
![Page 21: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/21.jpg)
Community Centres Custom Homes
Elevated Single Family Residence
Schools
ICF Designs For Efficiency and Survivability
Building Types
21
![Page 22: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/22.jpg)
Construction Time With ICF.
Thermal Resistance.
ICFs are considered by ICC and IECC as mass walls
with continuous insulation
Typical whole wall ICF assembly has an R value of
R24
ICFs exceed the requirements for all climate zones
for commercial thermal envelopes above and below
grade.
![Page 23: High Performance Concrete Building Design Insulating ...](https://reader031.fdocuments.net/reader031/viewer/2022012022/6169b91511a7b741a34aa47f/html5/thumbnails/23.jpg)
CICFI.org