high efficiency fire tube boiler - JMaterials Corporation Boiler/Taijune Fire Tube Steam... ·...
Transcript of high efficiency fire tube boiler - JMaterials Corporation Boiler/Taijune Fire Tube Steam... ·...
ECAT-EN-HEF-V1.0 2009.11
high efficiency
fire tube boiler
A professional engineer designer and manufacturer ofboilers and pressure vessels with over 30 years of experience
,
ASME S & U STAMP . ISO 9001 . CHINA SQL SHOP
fire tube boiler
HEF type three-pass fire tube boilers assure continuous operation at 1:5 of turn down ratio andstill maintain boiler efficiency as high as 88~90%. Besides it is possible to increase efficiency tomore than 92% by adding heat recovery equipment.
HEF type boilers have sufficient heating surface and wet-back design ensuring high durability.
Advanced combustion system with wide variety of fuel, such as heavy oil, diesel oil, gas andwaste liquid improves efficiency greatly and easy maintenance and operation.
Multi boiler water level control devices ensure safety operation for the boilers.
Start-up time is short. It takes about 15 minutes from cold ignition to generating steam.
Simple and durable construction and combustion system allow users to easily handle theoperation and maintenance.
All data and images shown in this brochure are for reference only. The manufacturerreserves the right to modify it without notifications.
With over 30 years of experience and precise engineering and strictquality control system, Taijune Boiler has created world-class boilers,pressure vessels and energy-saving equipment and built its’ reputationin high product efficiency, high safety and stability trusted by users fromwide variety of industries.
Oil & gas fired types
1
cut-away view of 3-pass fire tube boilerand the diagram of gas flow
B
C
AD
L
M
E
G
A
F
K
J
H
I
burner port
left front smoke box
A
F
E
D
C
B
DESCRIPTION
right front smoke box
corrugated furnace(1st pass)
G
2nd pass smoke tubes
2nd pass smoke tubes
boiler shell
hot insulation
steam drum manhole
H
M
L
K
J
I
combustion chamber manhole
wet-back furnace end
rear smoke box
exhaust outlet connection
burner
blower motor
steam pressuregauge
front smokebox door
pressure regulator
level column & gaugelevel controller
steam outlet valve
safety relief valve
rear smokebox door
feed water pumps
exhaust outletconnection
2
3
Remarks: 1. The above data is based on 1.0MPa boiler design pressure.2. The above data may be changed without notifications.3. Hot water boilers are available upon requests.
boiler performance curve
20 40 60 80 100
150
175
200
225
250
275
300
exh
au
stg
as
tem
p.℃
boiler load %
CO %2
10
11
12
13
14
15
16
75
80
85
90
95
bo
ile
re
ffic
ien
cy
CO2
exhaust gas temp.
boiler efficiency
specification table
fuel properties
Remarks: Fuel properties may vary by geographical locations and countries.
saturation table - pressure increment
4
A
B
C
D
E
F
G
H
I
J
KL
A B C D��
��
DE
SC
RIP
TIO
N
oil
ma
ke
-up
pu
mp
fue
ld
ay
tan
k
fue
lb
oo
stp
um
p
pre
ssu
rea
tom
izin
gb
urn
er
bo
ile
rp
rop
er
ch
imn
ey
fee
dw
ate
rp
um
p
E F G H
fore
dd
raf t
fan
so
f tw
ate
rsto
rag
eta
nk
wa
ter
so
f te
ne
r
sa
ltb
ath
I J K L
ch
em
ica
ld
osin
gp
um
p
refe
ren
ce
flo
wd
iag
ram
Re
ma
rks:
Th
efu
elfl
ow
inth
isd
iag
ram
isfo
rp
ressu
rea
tom
izin
gh
ea
vy
oil
fire
db
urn
ers
.
5
DISTRIBUTOR:
high efficiency fire tube boiler
ASME S & U STAMP . ISO 9001 . CHINA SQL SHOP
TAIJUNE ENTERPRISE CO LTD., .ADDRESS NO 6 WUNMING 2ND ST KUEISHANHSIANG TAOYUAN HSIEN 333 TAIWANTEL 886 3 3281406 FAX 3 3283632
E MAIL sales taijune com tw
GLOBAL SITE http://www.taijune.comCHINA OFFICIAL SITE: http://www.taijune.net
: . .
, , ,
:+ - - : -
- : . .
:
+886-
@
Copyrights © 2009 Taijune Enterprice Co., Ltd. All rights reserved.This brochure may not be copied or re-produced in whole or in partswithout the permission of the manufacturer.