high efficiency cast iron oil-fired...
Transcript of high efficiency cast iron oil-fired...
•OfferedexclusivelybyFerguson®
•87%AFUE,ENERGYSTAR®certified•0.6to1.35GPHinfoursizes•Chimneyvented,optionaldirectventkitavailable(sizes147,189)
•Integratedboilercontrol•3-passcastironheatexchanger•Fully-opening,reversible,castironswingdoor
•Returnwatermixingtube•Castironsectionconnectors•Lifetimelimitedwarrantyonheatexchanger
Standard Features
TM
high efficiencycast iron oil-fired boiler
112"NPT SYSTEM RETURN
CONNECTION
19" MIN.BURNER SWING
DOOR CLEARANCE(FULLY OPEN)(SEE NOTE 3)
FRONT SERVICECLEARANCE
(FLUEWAY CLEANING)
DRAIN VALVE
CLEANOUT COVER
SMOKEBOX COLLAR
COLLARDIA.
FLAMEOBSERVATION
PORT
BURNERSWINGDOOR
TEMP/PRESSUREGAUGE
RELIEFVALVE
BECKETT AFGBURNER(SHOWN)
SPANNER BAR W/ADJUSTABLE LEGS
112"NPT SYSTEM
SUPPLYCONNECTION
2138"
3178"
BOILERCONTROL
NOTES: 1. THIS DIMENSION INCREASES AND IS CONTROLLED BY SMOKEPIPE ARRANGEMENT. 2. DRAIN VALVE AND RELIEF VALVE/FITTINGS SHIPPED LOOSE. 3. BOILER SHIPPED WITH STANDARD RIGHT HAND HINGE CONFIGURATION, BUT CAN BE CONVERTED TO LEFT HAND HINGE. APPLY CLEARANCE ACCORDINGLY.
12" MINREAR SERVICE
CLEARANCE(SEE NOTE 1)
1314"
20 "34 5 "3
4
SMOKEBOXPRESURETAPPING
31116"
IMMERSIONWELL
Technical Information
Additional Standard Features
Model
Dimensions (Inches)
AFUE%
Burner Capacity
Net AHRI
Ratings (MBH)
WaterContent(Gal.)
Heating Transfer Surface
Area(Sq. Ft.)
Approximate Shipping Weight (lbs.)GPH MBH
DOE HeatingCapacity(MBH)A B C
FORCEOL084 17 24 5 87 0.60 84 73 63 7.7 13.29 430FORCEOL115 17 24 5 87 0.80 115 100 87 7.7 13.29 430FORCEOL147 23 24 6 87 1.05 147 129 112 11.08 20.29 545FORCEOL189 29 30 6 87 1.35 189 166 144 14.46 27.29 658
ASM
E
H
TheNetAHRIRatingsshownarebasedonapipingandpickupallowanceof1.15.
• Fullypackaged• Integratedboilercontrolsystem• 3450RPMflameretention Beckettoilburner• BeckettGeniSYSprimarycontrol• Returnwatermixingtube• GrundfosUPS15-58circlulator
• Electronicignitor14KV• Cleancutfuelpump• Tridcator• Reliefvalve• Drainvalve• Integratedliftinglegs (forlevelinstallation)
Model
Min. Chimney Requirements Direct Vent SystemRound Inch
Diam.Rectangle(Inches)
Height(Feet)
Kit PartNumber
Vent Connector Diameter (In.)
FORCEOL084 6 8x8 15 N/A N/AFORCEOL115 6 8x8 15 N/A N/AFORCEOL147 6 8x8 15 106401-01 5FORCEOL189 7 8x8 15 106401-01 5
Note:Returnfittingsanddrainvalveshippedloose.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepiping,etc.