Heavy Photon Search experiment in Hall-B

33
Heavy Photon Search experiment in Hall-B slides/ideas borrowed/stolen from talks of S. Stepanyan, J. Jaros, T. Nelson Special thanks to S. Stepanyan M. Guidal, IPN Orsay

description

Heavy Photon Search experiment in Hall-B. M. Guidal, IPN Orsay. slides/ideas borrowed/stolen from talks of S. Stepanyan, J. Jaros, T. Nelson Special thanks to S. Stepanyan. What is a “Heavy Photon”? aka “Dark Photon”, “Hidden Sector Photon”. - PowerPoint PPT Presentation

Transcript of Heavy Photon Search experiment in Hall-B

Page 1: Heavy Photon Search  experiment in Hall-B

Heavy Photon Search experiment in Hall-B

slides/ideas borrowed/stolen from talks of S. Stepanyan, J. Jaros, T. Nelson

Special thanks to S. Stepanyan

M. Guidal, IPN Orsay

Page 2: Heavy Photon Search  experiment in Hall-B

• A heavy photon (A’) is a conjectured U(1) force particle, a massive (~100 MeV) vector boson with weak couplings to electrons. If it exists, it

kinetically mix with our (SM) photon, inducing small couplings to electric charge.

• is expected to be of order 10-3

• m is expected ~ 10–1000 MeV

(Loops of heavy particles coupling both to A’ and )

What is a “Heavy Photon”?aka “Dark Photon”, “Hidden Sector Photon”

Page 3: Heavy Photon Search  experiment in Hall-B

Does Dark Matter Couple to Heavy Photons?N. Arkani-Hamed, D.P. Finkbeiner, T.R.Slayter, and N. Weiner, Phys. Rev.D79, 015014 (2009)

M. Pospelov and A. Ritz, Phys. Lett. B671, 391 (2009)

• Observation of unexpected fluxes of e± in the cosmic rays prompted explanations involving DM annihilation.

• Dark matter coupling to the A’ could explain DM annihilation into e+e –

theory

PAMELA e+/e- FERMI/HESS e Flux

Page 4: Heavy Photon Search  experiment in Hall-B

Fixed Target Experiments are an Ideal Hunting Ground

Page 5: Heavy Photon Search  experiment in Hall-B

Heavy Photon Signatures• A heavy photon appears as a narrow e+e- resonance on a copious

background of QED tridents.

• The A’ lifetime depends on mass and

c ~ 0.8 cm (E0/10 GeV) (10-4/)2 (100 MeV/mA’)2

Displaced A’ decay vertices can be identified over much of the m- parameter space, distinguishing them from QED tridents.

Trident Background

A’ Signal

Decay Length c

Bump HuntA’ Signal Trident Background

*

Page 6: Heavy Photon Search  experiment in Hall-B

HPS Design evolved from BEST ConceptJ.D. Bjorken, R. Essig, P.Schuster, and N. Toro, Phys. Rev. D80, 2009,075018

• A’ kinematics forward coverage required:EA’ Ebeam

A’ 0decay = mA’/EA’

Want m/m ~ 1% for bump huntWant z ~ 1mm

• Vertexing A’ decays requires detectors close to the target. Bump hunting needs good momentum/mass resolution. Both need tracking and a magnet.

• Trigger with high rate Electromagnetic Calorimeter downstream of the magnet to distinguish e+ and e-.

• Survive beam backgrounds by spreading them out maximally in time and avoiding multiple scattered and degraded electrons

Need CEBAF 100% duty cycleNeed very high rate DAQAvoid “Wall of flame”

e+ and e-

entering ECal

Page 7: Heavy Photon Search  experiment in Hall-B

HPS Overview• Forward, compact spectrometer/vertex detector identifies heavy photon

candidates with invariant mass and decay length (1T analyzing magnet).

• EM Calorimeter provides fast trigger and electron ID.

• Small cross sections and high backgrounds demand large luminosities. HPS survives beam backgrounds by spreading them out maximally in time, capitalizing on 100% CEBAF duty cycle and employing high rate DAQ.

• Muon detector for alternate trigger, muon ID

• All detectors are split above and below the beam to avoid the “wall of flame” from multiple Coulomb scattered primaries, bremsstrahlung, & degraded electrons.

Page 8: Heavy Photon Search  experiment in Hall-B

CEBAF Beam and HPS Beamline• HPS sits behind CLAS in Hall B.

• CEBAF meets Beam Requirements E 2.2, 6.6 GeV p/p 10-4

I 100-1000 nA I/I < 5% x,y < 30 µm halo < 10-5

• Beam position stability (<30 µm) OK using exiting BPMs and Fast Feedback and corrector magnets.

• Mechanical Vibrations not a problem. Measured to be ± 2 µm on forward carriage.

New optics/quadsgives10 µm spots

quads chicane dump

Halo measured <10-5

Expected at 12 GeV

Page 9: Heavy Photon Search  experiment in Hall-B

MC Tracker Studies Radiation Damage in Layer 1 Charged Particle Occupancy ( e± hits/cm2/month ) in Layer 1 Si strip detector

vs height above beam

Large but manageable dose oninnermost strips. They remainfunctional up to 6 x 1015/cm2 (6 mn) .

Occupancies are high, but manageable.Occupancy 1% beyond “dead zone” at Y = 1.5 mm (above electron beam).

DeadZone

400 nA on .25% X0 target

Sensitive Area ≥ 1.5 mm

Need to confirm full GEANT4 and EGS5 Monte Carlo studies

Page 10: Heavy Photon Search  experiment in Hall-B

MC Tracker Performance• Stand-alone pattern recognition is 98% efficient in presence of realistic

backgrounds. Only ~ 1 % of tracks have 1 miss-hits.

• Track, vertex quality, and trajectory cuts nearly eliminate vertex tails.

Before quality cuts

After quality cuts

Tracks with miss-hits make tails

Vertex Resolution along the beam direction, Zv

Page 11: Heavy Photon Search  experiment in Hall-B

Vertex Search Trident rejection is all in the tails!

• Trident vertices originate in the target, Zv = 0.• A’ decays can extend to large Zv.• Count vertices beyond Zcut to minimize trident background.

Ebeam = 5.5 GeV ’/ = 10-8.5

’/ = 10-9.5

Vertex Distribution for mA’ = 200 MeV ± 1.25

Page 12: Heavy Photon Search  experiment in Hall-B

MC Trigger PerformanceFull GEANT4 simulations are used to study trigger occupancies and rates.

• Occupancies OK for 8ns window and 100 MeV threshold

• Cluster, Energy, and Geometry cuts yield a trigger rate < 30 kHz

Trigger (6.6. GeV) 2 clusters 0.5 < E1,2< 5.0 GeV E1 + E2 < Ebeam

E < 4.0 GeV Co-planar

• Can the EM calorimeter efficiently trigger the experiment at <50kHz?

Page 13: Heavy Photon Search  experiment in Hall-B

HPS Reach*6.6 and 2.2 GeV Reach

25

* Small changes since proposal: muons added at high masses, improving reach; low mass cut-off was about 18, now 25 MeV.

Page 14: Heavy Photon Search  experiment in Hall-B

HPS Collaboration

Jlab Hall B & Collaborators, SLAC Group , Fermilab, UCSC 16 Institutions, 58 and counting Physicists and Engineers

Page 15: Heavy Photon Search  experiment in Hall-B

HPS Proposed Run Plan• Stage I Test Run (6 GeV Era)

2 weeks installation 1 week commission 1 week data run 2.2 GeV 1-100 nA 0.125% X0

0.6 x 106 s• Stage II Data Runs (12 GeV Era)

1 month installation ½ month commission 2 x 3* month data runs

2.2 GeV 200 nA 0.125% X0

9 x 106 s *assumes 100% efficiency

6.6 GeV 450 nA 0.25% X0

9 x 106 s

Install Spring 2012 before summerdown for CEBAF 12 GeV Upgrade

Install in CEBAF 12 GeV Era, late 2014 or 2015.

Stage I Test Run approved

PAC37 Approved Stage II Full HPS approved contingent on Test Run results

Page 16: Heavy Photon Search  experiment in Hall-B

Staging a challenging experimentKey environmental questions:• Can Si microstrip detectors be operated downstream of a target with

manageable occupancies and without radiation damage in close proximity to an intense electron beam?

• Can the EM calorimeter trigger the experiment at an acceptable trigger rate (<50kHz)?

• Is detector performance in the presence of realistic backgrounds good enough for the physics?

Two ways to answer these questions. We’ve done one. We need both! Extensive full GEANT4 and EGS5 Monte Carlo studies of trigger rates,

tracker occupancies, tracker pattern recognition efficiencies and purities, and tracker and vertexing performance in the presence of backgrounds.

Stage I Test Run (proposed for Spring 2012) to check MC calculations, measure occupancies and trigger rates, and exercise detector.

Page 17: Heavy Photon Search  experiment in Hall-B

Stage I Develops HPS Hardware, DAQ, Beams HPS Hardware, DAQ, and beams are needed to answer critical environmental

questions for Stage I, but are also an essential investment in full HPS.

• Use existing Hall B beamline and diagnostics (Target - 0.125% r.l. W-target (4mm), 3 wire beam profiler, additional calibration foil 0.25 r.l.).

• Build simplified si tracker system (20 vs 106 modules) (only stereo modules)• Build new Ecal Enclosure for existing (~460) PbWO4 crystal modules.

Ecal will serve for full HPS too (Vacuum chamber between 2 parts of the ECal)• Adapt existing SLAC (tracker) and Jlab (Ecal) architectures for readout and data

acquisition.

Page 18: Heavy Photon Search  experiment in Hall-B

Layout of HPS test setup in Hall B

Standard electron beam line

CLAS

Vacuum chamber between 2 parts of the ECal

Upstream flange with feedthroughs for target and SVT controls

Vacuum chamber through the magnet

Photon beam dump

Off axis by ~4’’

Page 19: Heavy Photon Search  experiment in Hall-B

Beam parameters and beam line configuration

Vacuum through out the system on a way of primary and scattered electrons, and bremsstrahlung photons

The target and the Si-tracker installed inside a vacuum enclosure

Beam profiler at the target location Photon beam dump downstream of the

chicane and adequate shielding Adequate beam diagnostics for beam

profile, position and current measurements and monitoring

Parameter Requirement Unit

E 2200 MeV

δp/p < 10-4

Current ~ 200 nA

Current Instability < 5 %

σX < 300 (< 100) μm

σY < 30 (< 100) μm

Position Stability < 30 μm

Divergence < 100 μrad

Beam Halo (> 5σ) < 10-5

Never was requested for any Hall B experimentsWas not looked at this level

Page 20: Heavy Photon Search  experiment in Hall-B

CEBAF Beam ParametersBeam current measured with using SLM

(from recent Hall B run)

Typical beam size measured in Hall B (from 2.2 GeV run)

Most of requested beam parameters are routinely delivered to Hall B

CW beam, 1497 MHz bunch repetition 499 MHz/hall

Beam energy 0.8 – 6 GeV, energy spread < 10-4

At any requested current, stability < ±5%

Smaller beam sizes (< 30 m) and/or very tight specs on beam position stability (< 30 m) never were requested

Beam position stability, from beam profile scans, is < 50 m for X position, and < 30 m for Y

X≈50 m Y≈90 m

Page 21: Heavy Photon Search  experiment in Hall-B

Optimization of beam opticsOptics program “elegant” (ELEctron Generation ANd Tracking) is used to optimize Hall B beam line for 2.2 GeV (2 pass) beam at the HPS targetEmittances x =1x10-9 m-rad and y = 1x10-9 m-rad are used as input

Arne Freyberger

One of the optimization runs was to get the smallest possible beam sizes in both X and Y. With the existing B-line optics, beam sizes of ~30 m is achievable

Another optimization was run to get an asymmetric beam. Required beam profile X ≈250 m and Y≈20 m is also achievable

Page 22: Heavy Photon Search  experiment in Hall-B

Optimization of Hall B optics Optics optimization was tested during TPE run with a 2.2 GeV (2 pass) electron beam Parameters were set for a beam profile of X≈300 m and Y≈10 m at the Hall B

”tagger” beam profiler (~8 meters upstream of the proposed HPS target location) Several beam profile scans with different speed of wire scanner and data readout

were performed to check systematics

The wire scan speed was 0.1mm/s, beam motion faster than 1Hz is included in the scan.Position stability (from Y-peak position measured in various scans) < 20 m (feedback system was not initiated)

X≈280 m Y≈20 m

Page 23: Heavy Photon Search  experiment in Hall-B

Beam line simulations GEANT4 model of the HPS beam line is ready for optimization of beam line elements

(vacuum tract, flanges, photon beam dump, shielding …) Simulation is based on experience gained from TPE beam line optimization

Maurizio Ungaro Exit of the last vacuum chamber

Electron beam line continues in vacuum

Photon beam exits to He bag to photon dump

Photon beam dump

Page 24: Heavy Photon Search  experiment in Hall-B

Resources and schedule Engineering and design will be done mostly by HPS collaborators (SLAC and ORSAY)

Hall B engineering group will be involved in coordinating of design and engineering efforts from contributing institutions, and in integrating of various new elements into the beam line

Key personal for beam line design: at Jlab Arne Freyberger and Stepan Stepanyan, at SLAC Ken Moffeit, Marco Oriunno, Dieter Walz, and Clive Field, at Orsay Philippe Rosier and Emmanuel Rindel. For beam diagnostics and slow control: Nerses Gevorgyan (Yerevan) and Hovanes Egiyan (JLAB)

Page 25: Heavy Photon Search  experiment in Hall-B

HPS Test Run• Primary HPS Test Run Goal : measure occupancies in detector elements, Si-tracker layers

and Ecal modules, positioned in close proximity to the beam plane. It requires beam transport in vacuum, working si sensors, working Ecal, and DAQ. In the process, we get valuable experience controlling beams and commissioning HPS hardware, and we get a start on HPS.

Page 26: Heavy Photon Search  experiment in Hall-B

• Primary HPS Test Run Goal : measure occupancies in detector elements, Si-tracker layers and Ecal modules, positioned in close proximity to the beam plane. It requires beam transport in vacuum, working si sensors, working Ecal, and DAQ. In the process, we get valuable experience controlling beams and commissioning HPS hardware, and we get a start on HPS.

• Secondary objectives depend on establishing useful running conditions, delivering a si system capable of track finding, and providing a fully functioning and integrated DAQ. This will let us demonstrate full HPS capability (tracker alignment, track finding efficiencies and purities,momentum and vertex resolution, trigger development,…)

HPS Test Run

Page 27: Heavy Photon Search  experiment in Hall-B

• Primary HPS Test Run Goal : measure occupancies in detector elements, Si-tracker layers and Ecal modules, positioned in close proximity to the beam plane. It requires beam transport in vacuum, working si sensors, working Ecal, and DAQ. In the process, we get valuable experience controlling beams and commissioning HPS hardware, and we get a start on HPS.

• Secondary objectives depend on establishing useful running conditions, delivering a si system capable of track finding, and providing a fully functioning and integrated DAQ. This will let us demonstrate full HPS capability (tracker alignment, track finding efficiencies and purities,momentum and vertex resolution, trigger development,…)

• To run the HPS test experiment there is no need for any new major beam line instrumentation. Hall B beam line is adequately equipped for this experiment. Requested beam parameters are comparable to ones routinely delivered to Hall B. Some of critical beam optics parameters are simulated and already tested, and will satisfy needs of the HPS test run. Design of new beam line elements are in progress, critical parts have workable solution.

HPS Test Run

Page 28: Heavy Photon Search  experiment in Hall-B

• Primary HPS Test Run Goal : measure occupancies in detector elements, Si-tracker layers and Ecal modules, positioned in close proximity to the beam plane. It requires beam transport in vacuum, working si sensors, working Ecal, and DAQ. In the process, we get valuable experience controlling beams and commissioning HPS hardware, and we get a start on HPS.

• Secondary objectives depend on establishing useful running conditions, delivering a si system capable of track finding, and providing a fully functioning and integrated DAQ. This will let us demonstrate full HPS capability (tracker alignment, track finding efficiencies and purities,momentum and vertex resolution, trigger development,…)

• To run the HPS test experiment there is no need for any new major beam line instrumentation. Hall B beam line is adequately equipped for this experiment. Requested beam parameters are comparable to ones routinely delivered to Hall B. Some of critical beam optics parameters are simulated and already tested, and will satisfy needs of the HPS test run. Design of new beam line elements are in progress, critical parts have workable solution.

• Fully Commissioned Test Run Apparatus can do physics. * Search for heavy photons in the parameter space domain favored by a “heavy photon” explanation of the muon g-2 anomaly. * Search in the “vertexing” domain.

HPS Test Run

Page 29: Heavy Photon Search  experiment in Hall-B
Page 30: Heavy Photon Search  experiment in Hall-B

Backups

Page 31: Heavy Photon Search  experiment in Hall-B

HPS test setup

S. Stepanyan, HPS review, March 1 (2011) 31

Analyzing magnet operated at 0.5 Tm

• Electromagnetic Calorimeter - 460 PbWO4 modules with APD readout in a temperature controlled enclosure, starting @ 15mrad

• Vacuum chamber between 2 parts of the ECal

• Si tracker - 5 layers, 10 stereo readout planes positioned at 15mrad from the beam plane

• Target - 0.125% r.l. W-target (4m), 3 wire beam profiler, additional calibration foil 0.25 r.l.

Two dipoles, operated at 0.25 Tm, to keep primary electron beam on the nominal beam axis

Page 32: Heavy Photon Search  experiment in Hall-B

Present Limits and Region of InterestJ.D. Bjorken, R. Essig, P.Schuster, and N. Toro, Phys. Rev. D80, 2009,075018 (BEST)

’/

2

Both “naturalness” arguments and fits to astrophysical data suggest ’/ 2 ~ 10-4 – 10-10

mA’ ~ MeV - GeV

Both resonance-bump and separated decay vertex signatures are needed to explore this region

Page 33: Heavy Photon Search  experiment in Hall-B

HPS Test Run Goals• Primary HPS Test Run Goal (measuring occupancies and trigger rates) requires

beam transport in vacuum, working si sensors, working Ecal, and DAQ. In the process, we get valuable experience controlling beams and commissioning HPS hardware, and we get a start on HPS.

• Secondary objectives depend on establishing useful running conditions, delivering a si system capable of track finding, and providing a fully functioning and integrated DAQ. This will let us demonstrate full HPS capability. * Tracker alignment * Track finding efficiencies and purities * Momentum and vertex resolution * Trigger development Modest extra expense gives greatly expanded capability

• Fully Commissioned Test Run Apparatus can do physics. * Search for heavy photons in the parameter space domain favored by a “heavy photon” explanation of the muon g-2 anomaly. * Search in the “vertexing” domain.