Heavy Duty Vertical Cantilever Slurry

4
www.keystonepumps.com Heavy Duty Vertical Cantilever Slurry Pumps For Industrial Applications

Transcript of Heavy Duty Vertical Cantilever Slurry

Page 1: Heavy Duty Vertical Cantilever Slurry

www.keystonepumps.com

Heavy Duty Vertical Cantilever Slurry Pumps For Industrial Applications

HDV OPTIONS

Control Panel

Simplex / Duplex

Ground Fault & Ground Check Monitoring

Custom Designs Available

Jet Ring

Settled solids are induced into suspension by the water jetting action of the nozzles

HDV FEATURES & ACCESSORIES

Unit 307 – 2999 Underhill AveBurnaby, B.C. V5A 3C2

Toll-free: 1.888.875.3323Phone: 604.227.3555

Fax: 604.229.0494Email: [email protected]

www.keystonepumps.com2014 Keystone Pumps, All rights reserved

HDV Agitator

Solids are propelled into suspension by the mixing

action of the blades

Direct Drive

The electric motor is mounted vertically, directly coupled to the bearing housing. The motor drives the pump using a coupling assembly

V-Belt Drive

The electric motor is mounted vertically to the bearing housing frame on an adjustable motor mounting plate. The motor drives the pump using a V-belt drive assembly

Agitator Open Suction

OR

OR

Tailpipe / Strainer

The suction extends deeper into the sump for operation at greater sump depths

Page 2: Heavy Duty Vertical Cantilever Slurry

Keystone HDV Low-Head Hydraulic Performance

Discharge Size [in. (mm)] 2" (50)Impeller Diameter [in. (mm)] 8.46" (215)Min. Impeller Diameter [in. (mm)] 6.77" (172)Max Solid Size [in. (mm)] 0.63" (16)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F75 / F100Maximum Motor Power HP 30 / 75Maximum Motor Frame Size 286T / 365T

Discharge Size [in. (mm)] 3" (75)Impeller Diameter [in. (mm)] 8.46" (215)Min. Impeller Diameter [in. (mm)] 6.77" (172)Max Solid Size [in. (mm)] 0.86" (22)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F75 / F100Maximum Motor Power HP 30 / 75Maximum Motor Frame Size 286T / 365T

Discharge Size [in. (mm)] 4" (100)Impeller Diameter [in. (mm)] 9.05" (230)Min. Impeller Diameter [in. (mm)] 7.24" (184)Max Solid Size [in. (mm)] 1.26" (32)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F75 / F100Maximum Motor Power HP 30 / 75Maximum Motor Frame Size 286T / 365T

Discharge Size [in. (mm)] 6" (150)Impeller Diameter [in. (mm)] 9.84" (250)Min. Impeller Diameter [in. (mm)] 7.82" (200)Max Solid Size [in. (mm)] 1.26" (32)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F100 / F150Maximum Motor Power HP 75 / 150Maximum Motor Frame Size 365T / 445T

Discharge Size [in. (mm)] 8" (200)Impeller Diameter [in. (mm)] 14.76" (375)Min. Impeller Diameter [in. (mm)] 11.81" (300)Max Solid Size [in. (mm)] 1.58" (40)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F150 / F175Maximum Motor Power HP 150 / 250Maximum Motor Frame Size 445T / 449T

Discharge Size [in. (mm)] 10" (250)Impeller Diameter [in. (mm)] 20.47" (520)Min. Impeller Diameter [in. (mm)] 16.37" (416)Max Solid Size [in. (mm)] 2.2" (56)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F150 / F175Maximum Motor Power HP 150 / 250Maximum Motor Frame Size 445T / 449T

FEET

GPM

100

90

80

70

60

50

40

30

20

10

0

100

HDV

50

L

HDV

75

L

HDV

100

L

HDV

150

L

HDV

200

L

HDV

250

L

200300

400500

7501000

15002000

30005000

7500

POWER GENERATION

– Coal Pile Runoff– Coal Crusher Sumps– Coal Tunnel Sumps– Coal Fines Recovery– FGD Blowdown Sumps– Bottom Ash Transport– Fly Ash Sumps and Ponds– Wastewater and Basement Sumps

SAND & GRAVEL

– Weir Overflow– Dust Suppression– Recycle Water– Wheel Wash Pump– Cyclone Feed– Dredging– Barge Unloading

PULP & PAPER / FOOD PROCESSING

– Wood Yard Runoff– Wastewater and Basement Sumps– Food Processing Waste– Juicer Sumps

MINING / STEEL

– Mine Dewatering– Collection & Runoff Sumps– Emergency Dump Pond– Tailings Pond Cleanout– Kaolin Clay– Red Mud Recovery– Magnetite Recovery– Clarifier Sludge– Slag Pits– Scale Pits– Swarf Boxes– Flume Flushers– Interceptor Pumps

Keystone HDV Medium-Head Hydraulic Performance

The Keystone HDV delivers continuous, heavy-duty performance with a full range of design options. Built to handle your toughest applications!

Keystone LabyrinthSeal / Flinger(Optional Third Party Seals Available)

V-Belt or Direct MotorDriveConfigurations Available

Heavy Duty Cast DuctileIron Bearing Housing

316 Stainless SteelFasteners Standard

316 Stainless Steel & 17-4 PHNon-Cast Wet End Components

Heavy Duty Cylindrical RollerBearing Grease Lubricated

Keystone LabyrinthSeal / Flinger

(Optional Third Party Seals Available)

Heavy Duty Spherical RollerBearing Grease Lubricated

4140 HTSR Shaft(Optional 17-4 PH Available)

150# ANSI “B 16.5” Discharge Flange

Heavy Duty Discharge Hose(Optional Discharge Pipe Available)

Agitator(Optional Open Suction Available)

ASTM A532 CL. III Type AHigh Chrome Constructionfor Liquid End Components(Optional CD4MCU Available)

HDV

50L

HDV

75L

HDV

100

LH

DV 1

50L

HDV

200

L

HDV

100

MH

DV 7

5MH

DV 1

50M

HDV

200

M

HDV

250

L

Discharge Size [in. (mm)] 3" (75)Impeller Diameter [in. (mm)] 13.38" (340)Min. Impeller Diameter [in. (mm)] 10.70" (272)Max Solid Size in. (mm) 1.38" (35)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F100 / F150Maximum Motor Power HP 75 / 150Maximum Motor Frame Size 365T / 445T

Discharge Size [in. (mm)] 4" (100)Impeller Diameter [in. (mm)] 13.38" (340)Min. Impeller Diameter [in. (mm)] 10.70" (272)Max Solid Size [in. (mm)] 1.56" (40)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F100 / F150Maximum Motor Power HP 75 / 150Maximum Motor Frame Size 365T / 445T

Discharge Size [in. (mm)] 6" (150)Impeller Diameter [in. (mm)] 16.93" (430)Min. Impeller Diameter [in. (mm)] 13.60" (345)Max Solid Size [in. (mm)] 2.16" (55)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F150 / F175Maximum Motor Power HP 150 / 250Maximum Motor Frame Size 445T / 449T

Discharge Size [in. (mm)] 8" (200)Impeller Diameter [in. (mm)] 18.50" (470)Min. Impeller Diameter [in. (mm)] 14.80" (376)Max Solid Size [in. (mm)] 2.36" (60)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F150 / F175Maximum Motor Power HP 150 / 250Maximum Motor Frame Size 445T / 449T

FEET

GPM

220

200

180

160

140

120

100

80

60

40

0

100

HDV

75

M

HDV

100

M

HDV

150

M

HDV

200

M

200300

400500

7501000

15002000

25003000

4000

Page 3: Heavy Duty Vertical Cantilever Slurry

Keystone HDV Low-Head Hydraulic Performance

Discharge Size [in. (mm)] 2" (50)Impeller Diameter [in. (mm)] 8.46" (215)Min. Impeller Diameter [in. (mm)] 6.77" (172)Max Solid Size [in. (mm)] 0.63" (16)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F75 / F100Maximum Motor Power HP 30 / 75Maximum Motor Frame Size 286T / 365T

Discharge Size [in. (mm)] 3" (75)Impeller Diameter [in. (mm)] 8.46" (215)Min. Impeller Diameter [in. (mm)] 6.77" (172)Max Solid Size [in. (mm)] 0.86" (22)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F75 / F100Maximum Motor Power HP 30 / 75Maximum Motor Frame Size 286T / 365T

Discharge Size [in. (mm)] 4" (100)Impeller Diameter [in. (mm)] 9.05" (230)Min. Impeller Diameter [in. (mm)] 7.24" (184)Max Solid Size [in. (mm)] 1.26" (32)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F75 / F100Maximum Motor Power HP 30 / 75Maximum Motor Frame Size 286T / 365T

Discharge Size [in. (mm)] 6" (150)Impeller Diameter [in. (mm)] 9.84" (250)Min. Impeller Diameter [in. (mm)] 7.82" (200)Max Solid Size [in. (mm)] 1.26" (32)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F100 / F150Maximum Motor Power HP 75 / 150Maximum Motor Frame Size 365T / 445T

Discharge Size [in. (mm)] 8" (200)Impeller Diameter [in. (mm)] 14.76" (375)Min. Impeller Diameter [in. (mm)] 11.81" (300)Max Solid Size [in. (mm)] 1.58" (40)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F150 / F175Maximum Motor Power HP 150 / 250Maximum Motor Frame Size 445T / 449T

Discharge Size [in. (mm)] 10" (250)Impeller Diameter [in. (mm)] 20.47" (520)Min. Impeller Diameter [in. (mm)] 16.37" (416)Max Solid Size [in. (mm)] 2.2" (56)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F150 / F175Maximum Motor Power HP 150 / 250Maximum Motor Frame Size 445T / 449T

FEET

GPM

100

90

80

70

60

50

40

30

20

10

0

100

HDV

50

L

HDV

75

L

HDV

100

L

HDV

150

L

HDV

200

L

HDV

250

L

200300

400500

7501000

15002000

30005000

7500

POWER GENERATION

– Coal Pile Runoff– Coal Crusher Sumps– Coal Tunnel Sumps– Coal Fines Recovery– FGD Blowdown Sumps– Bottom Ash Transport– Fly Ash Sumps and Ponds– Wastewater and Basement Sumps

SAND & GRAVEL

– Weir Overflow– Dust Suppression– Recycle Water– Wheel Wash Pump– Cyclone Feed– Dredging– Barge Unloading

PULP & PAPER / FOOD PROCESSING

– Wood Yard Runoff– Wastewater and Basement Sumps– Food Processing Waste– Juicer Sumps

MINING / STEEL

– Mine Dewatering– Collection & Runoff Sumps– Emergency Dump Pond– Tailings Pond Cleanout– Kaolin Clay– Red Mud Recovery– Magnetite Recovery– Clarifier Sludge– Slag Pits– Scale Pits– Swarf Boxes– Flume Flushers– Interceptor Pumps

Keystone HDV Medium-Head Hydraulic Performance

The Keystone HDV delivers continuous, heavy-duty performance with a full range of design options. Built to handle your toughest applications!

Keystone LabyrinthSeal / Flinger(Optional Third Party Seals Available)

V-Belt or Direct MotorDriveConfigurations Available

Heavy Duty Cast DuctileIron Bearing Housing

316 Stainless SteelFasteners Standard

316 Stainless Steel & 17-4 PHNon-Cast Wet End Components

Heavy Duty Cylindrical RollerBearing Grease Lubricated

Keystone LabyrinthSeal / Flinger

(Optional Third Party Seals Available)

Heavy Duty Spherical RollerBearing Grease Lubricated

4140 HTSR Shaft(Optional 17-4 PH Available)

150# ANSI “B 16.5” Discharge Flange

Heavy Duty Discharge Hose(Optional Discharge Pipe Available)

Agitator(Optional Open Suction Available)

ASTM A532 CL. III Type AHigh Chrome Constructionfor Liquid End Components(Optional CD4MCU Available)

HDV

50L

HDV

75L

HDV

100

LH

DV 1

50L

HDV

200

L

HDV

100

MH

DV 7

5MH

DV 1

50M

HDV

200

M

HDV

250

L

Discharge Size [in. (mm)] 3" (75)Impeller Diameter [in. (mm)] 13.38" (340)Min. Impeller Diameter [in. (mm)] 10.70" (272)Max Solid Size in. (mm) 1.38" (35)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F100 / F150Maximum Motor Power HP 75 / 150Maximum Motor Frame Size 365T / 445T

Discharge Size [in. (mm)] 4" (100)Impeller Diameter [in. (mm)] 13.38" (340)Min. Impeller Diameter [in. (mm)] 10.70" (272)Max Solid Size [in. (mm)] 1.56" (40)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F100 / F150Maximum Motor Power HP 75 / 150Maximum Motor Frame Size 365T / 445T

Discharge Size [in. (mm)] 6" (150)Impeller Diameter [in. (mm)] 16.93" (430)Min. Impeller Diameter [in. (mm)] 13.60" (345)Max Solid Size [in. (mm)] 2.16" (55)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F150 / F175Maximum Motor Power HP 150 / 250Maximum Motor Frame Size 445T / 449T

Discharge Size [in. (mm)] 8" (200)Impeller Diameter [in. (mm)] 18.50" (470)Min. Impeller Diameter [in. (mm)] 14.80" (376)Max Solid Size [in. (mm)] 2.36" (60)Pump Frame Length [ft (mm)] 3 (900), 4 (1200), 5 (1500), 6 (1800)Bearing Housing Frame Size F150 / F175Maximum Motor Power HP 150 / 250Maximum Motor Frame Size 445T / 449T

FEET

GPM

220

200

180

160

140

120

100

80

60

40

0

100

HDV

75

M

HDV

100

M

HDV

150

M

HDV

200

M

200300

400500

7501000

15002000

25003000

4000

Page 4: Heavy Duty Vertical Cantilever Slurry

www.keystonepumps.com

Heavy Duty Vertical Cantilever Slurry Pumps For Industrial Applications

HDV OPTIONS

Control Panel

Simplex / Duplex

Ground Fault & Ground Check Monitoring

Custom Designs Available

Jet Ring

Settled solids are induced into suspension by the water jetting action of the nozzles

HDV FEATURES & ACCESSORIES

Unit 307 – 2999 Underhill AveBurnaby, B.C. V5A 3C2

Toll-free: 1.888.875.3323Phone: 604.227.3555

Fax: 604.229.0494Email: [email protected]

www.keystonepumps.com2014 Keystone Pumps, All rights reserved

HDV Agitator

Solids are propelled into suspension by the mixing

action of the blades

Direct Drive

The electric motor is mounted vertically, directly coupled to the bearing housing. The motor drives the pump using a coupling assembly

V-Belt Drive

The electric motor is mounted vertically to the bearing housing frame on an adjustable motor mounting plate. The motor drives the pump using a V-belt drive assembly

Agitator Open Suction

OR

OR

Tailpipe / Strainer

The suction extends deeper into the sump for operation at greater sump depths