HEAVY DUTY INDUSTRY FLOW/CONSUMPTION SENSOR S450 / …
Transcript of HEAVY DUTY INDUSTRY FLOW/CONSUMPTION SENSOR S450 / …
FLOW / CONSUMPTION SENSORS FLOW / CONSUMPTION SENSORS www.suto-itec.com
HEAVY DUTY INDUSTRY FLOW/CONSUMPTION SENSOR S450 / S452
www.suto-itec.com
Monitor your flow — optimize process efficiency
S450
S452
INDUSTRIAL DESIGN For outdoor applications
WIRELESS INTERFACE TO SENSOR SETTINGS
EASY TO CLEAN All wetted parts stainless steel
ATEX, IECEX AND GB EX APPROVAL
S450 / S452 FEATURES AT A GLANCE
S450 / S452 OPERATION PRINCIPLE
S450 / S452 FEATURES
The SUTO flow sensor S450 is based on the thermal mass flow principle. It measures volumetric standard flow over a wide measuring range. The result is pressure and temperature independent.
The S450 is designed specifically for harsh environments.
The IP67 casing allows all-weather applications. All parts which come into contact with the measurement medium are made of stainless steel 316L. This allows applications in pharmaceutical and food industry, but also the measurement of corrosive and contaminated gas. Installations in explosive environments can be done through the optional ATEX approval. Various gases can be measured such as air, oxygen, argon, carbon dioxide, natural gas, hydrogen, methane, etc.. Basically any gas mixture can be measured as long the mixing ratio and its components are known and constant.
Direct measurement of mass flow and standard flow without the need of pressure compensation
Wide range of tube sizes are supported with insertion type for big pipe diameters and inline types for small pipe diameters
No moving parts, non clogging
All parts which come into contact with the measurement medium are made of stainless steel 316L
Robust metal enclosure suitable for outdoor applications in harsh environment
Wireless interface for sensor settings on site
Display showing flow rates, consumption, medium temperature and diagnostic results
2 analogue outputs (4 ... 20 mA) and 1 pulse output
Available options:
- Fieldbus interface: HART, Modbus
- Hazardous approval ATEX: II 2 G Ex d IIC T4 IECEx GB Ex
- Bi-directional measurement
- Flow conditioner for R-thread measuring sections
FLOW / CONSUMPTION SENSORS FLOW / CONSUMPTION SENSORS
Insertion type installation through ball valve
Inline type installation through flanges or R thread
Sensor head can be rotated in 90° steps through the screw nut
Enclosure(IP67)
Wireless interface 2-line display
All parts in contact with the medium are of stainless steel 316L, no moving parts, low pressure loss.
Rotatable and removable sensor
2 conduit ports for separation of power and signal
S450 / S452 TECHNICAL DATA
S450 / S452 FEATURES AT A GLANCE
General Specifications
Measuring range: 0.4 ... 92.7 sm/s (standard range calibration)0.8 ... 185 sm/s (max range calibration)1.0 ... 224 sm/s (high speed calibration) (refer to table for flow measurement ranges in different tube diameters)
* sm/s: standard meter per second
Accuracy: ±(1.5 % of reading + 0.3 % full scale)
Stated accuracy at: Ambient/process temperature +23 °C ±3 °CAmbient/process humidity <90%, no condensationProcess pressure at 0.6 MPa
Repeatability: 0.25 % of reading
Response time t95: < 5 seconds
Sampling rate: Display and outputs are refreshed every 200 msec
Tube diameter: Insertion type: DN15 ... DN1500Inline type: DN15 ... DN80
Process connection: Insertion type: Inline type:
½” G-type thread (ISO 228-1) R-thread (ISO 7-1), Flange EN 1092-1, ANSI / B16.5, JIS B2220
Measuring medium: Any gases where the components and the mixing ration are constant and known. See order information for a list of standard gases.
Operatingtemperature:
-40 ... +150 °C (medium temp. insertion type)-40 ... +100 °C (medium temp. inline type)-40 ... +65 °C (ambient temperature)
Operating pressure: S450: 0 ... 1.6 MPa / S452: 0 ... 4.0 MPa
Analogue output: 2 x 4 ... 20 mA, up to 400 R load, active/passive selectable, measurement channel selectable, scaling programmable
Pulse/Alarm output: Either alarm or pulse output. 1 pulse per 1, 10 or 100 consumption units, Alarm programmable
Power supply: 16-30 VDC, 5 W
Enclosure: IP67
Sensor material: Stainless steel 1.4404 (SUS 316L)
Approvals: CE, RoHSATEX: II 2 G Ex d IIC T4 / GB3836 / IECEx(Optional)
Fieldbus:(Optional)
Modbus/RTUHART
www.suto-itec.com
Industrial communication through Modbus, M-Bus, HART
HART M-BusModbus
SCADA
Shaft option L (mm) H (mm)
A 220 469
B 160 409
C 300 549
130.0(max.)(Ex Version )
95.0(max.)
L
114.0(max.)
H(m
ax.)
At other standard conditions and in other gases flow ranges are different and data are available on request.
In larger pipe diameters flow can also be measured.
S452 DIMENSIONS (FLANGE TYPE)
S452 DIMENSIONS (THREAD TYPE)
S450 DIMENSIONS
130.0(max.)(Ex Version )
95.0(max.)
130.0(max.)(Ex Version )
95.0(max.)
AA
L1L
Weld-neckflange
L1L
Weld-neckflange 45º 45º
114.0(max.)
114.0(max.)
R(IS
O 7
-1)
(Ext
erna
l thr
ead)
R(IS
O 7
-1)
(Ext
erna
l thr
ead)
H(m
ax.)
H1(
max
.)H
(max
.)H
1(m
ax.)
Pipe nominal
size inch / (DN)
L total
length (mm)
L1 inlet
length (mm)
H total
height (mm)
H1 from pipe center to
casing top (mm)
R External Thread
1/2” (DN15) 300 210 210.8 200.15 R 1/2”
3/4” (DN20) 475 275 213.6 200.15 R 3/4”
1” (DN25) 475 275 217.0 200.15 R 1”
1¼” (DN32) 475 275 221.35 200.15 R 1¼”
1½” (DN40) 475 275 224.3 200.15 R 1½”
2” (DN50) 475 275 230.3 200.15 R 2”
Pipe nominal
size inch / (DN)
L total
length (mm)
L1 inlet
length (mm)
H total
height (mm)
H1 from pipe
center to casing top (mm)
1/2” (DN15) 300 210 247.65 200.15
3/4” (DN20) 475 275 252.65 200.15
1” (DN25) 475 275 257.65 200.15
1¼” (DN32) 475 275 270.15 200.15
1½” (DN40) 475 275 275.15 200.15
2” (DN50) 475 275 282.65 200.15
2½” (DN65) 475 275 300.55 208.05
3” (DN80) 475 275 314.45 214.45
Stated measuring ranges under following conditions: Standard flow in air Reference pressure: 1000 hPa Reference Temperature: +20 °C
Inch DN S-Range (m3/h)
M-Range (m3/h)
HS-Range (m3/h)
½” DN15 0.2 ... 45.6 0.4 ... 91.0 0.48 ... 110.16
¾” DN20 0.4 ... 89.1 0.9 ... 177.8 1.09 ... 215.3
1” DN25 0.6 ... 147.7 1.2 ... 294.7 1.82 ... 356.85
1½” DN40 1.5 ... 366.7 2.9 ... 731.9 4.36 ... 886.18
2” DN50 2.4 ... 600 4.8 ... 1198 7.26 ... 1450.04
2½” DN65 4.1 ... 1027 8.2 ... 2049 12.1 ... 2480.44
3” DN80 5.7 ... 1424 11.4 ... 2841 16.94 ... 3441.91
4” DN100 8.7 ... 2183 17.4 ... 4357 24.2 ... 5275.71
5” DN125 20 ... 3419.6 38 ... 6824.4 45.9 ... 8263.09
6” DN150 20 ... 4930 39 ... 9839 70.18 ... 11913.10
8” DN200 35 ... 8786 70 ... 17533 106.48 ... 21229.51
10” DN250 55 ... 13744 110 ... 27429 165.77 ... 33210.69
12” DN300 79 ... 19815 158 ... 39544 239.58 ... 47880.39
S450 / S452 VOLUMETRIC FLOW RANGES
FLOW / CONSUMPTION SENSORS
Inte
rnat
iona
l Edi
tion
(EN
) - 0
1/21
. ©
202
1 SU
TO iT
EC G
mb
H.
ww
w.su
to-it
ec.c
om
S450 / S452 ORDERING
Please use the following tables to assist in placing your order with our sales staff.
Visit our website or e-mail us:www.suto-itec.com [email protected]
Attention:* Measuring section connection and size must be combined to get the order number. Example: A1306 = R-thread DN50
Order No. DescriptionR200 0005 Oil- & grease-free cleaned option for flow sensors (for Oxygen it is already included in A 1009)
A553 0121 Sensor cable, 6-poles, AWG22, 7.5 mm outer diameter, w/shielding, black (per meter)
A553 0123 RS-485 cable, 2-poles, AWG (per meter)
S452 Flow sensor (In-line type)Order No. Code DescriptionS695 0452 S0452 S452, flow sensor, inline type
Process connection *
A130X A R-thread (ISO 7-1)
A132X B Flange EN 1092-1, PN40
A134X C Flange ANSI 16.5
Measuring section size *
1 A DN15 (1/2”)
2 B DN20 (3/4”)
3 C DN25 (1”)
4 D DN32 (1.25”)
5 E DN40 (1.5”)
6 F DN50 (2”)
7 G DN65 (2.5”)
8 H DN80 (3”)
Gas type
A1007 A Air
A1008 B CO2
A1009 C O2 (Oil- & grease-free cleaned)
A1010 D N2
A1011 E N2O
A1012 F Argon
A1013 G Natural Gas
A1014 H H2 (real gas calibration)
A1015 I Other gas (please specify)
A1016 J He (real gas calibration)
A1017 K C3H8
A1041 L O2, Ar, CO2 (real gas calibration)
Range
A Standard
A1271 B Max range
A1274 E High speed
Hazardous area approval
A1279 A None
A1280 B ATEX / GB3836 / IECEx
Output
A1284 A 2 x 4 ... 20 mA + pulse
A1285 B 1 x 4 ... 20 mA + HART + pulse
A1286 C 1 x 4 ... 20 mA + Modbus + pulse
Display
A1294 A Without display
A1295 B With display
S450 Flow sensor (Insertion type)Order No. Code DescriptionS695 0450 S0450 S450, flow sensor insertion type
Shaft length
A1200 A 220 mm Standard
A1201 B 160 mm
A1202 C 300 mm
Process connection
A G 1/2” Standard
A1006 B PT 1/2” Adapter
A1005 C NPT 1/2” Adapter
Gas type
A1007 A Air
A1008 B CO2
A1009 C O2 (Oil- & grease-free cleaned)
A1010 D N2
A1011 E N2O
A1012 F Argon
A1013 G Natural Gas
A1014 H H2 (real gas calibration)
A1015 I Other gas (please specify)
A1016 J He (real gas calibration)
A1017 K C3H8
A1041 L O2, Ar, CO2 (real gas calibration)
Range
A Standard
A1271 B Max range
A1272 CBi-directional standard range
A1273 DBi-directional max. range
A1274 E High speed
Hazardous area approval
A1279 A None
A1280 B ATEX / GB3836 / IECEx
Output
A1284 A 2 x 4 ... 20 mA + pulse
A1285 B 1 x 4 ... 20 mA + HART + pulse
A1286 C 1 x 4 ... 20 mA + Modbus + pulse
Display
A1294 A Without display
A1295 B With display
FLOW / CONSUMPTION SENSORS FLOW / CONSUMPTION SENSORS www.suto-itec.com
EUROPEAN OFFICE CHINA OFFICE ASIA / PACIFIC OFFICE
SUTO iTEC GmbH
Grißheimer Weg 2179423 HeitersheimGermanyTel: +49 (0) 7634 504 88-00Fax: +49 (0) 7634 504 88-19Email: [email protected]
SUTO iTEC (China) Co. Ltd
D3 Building, Unit A, 11/F, TCL International E City1001 Zhongshanyuan Road, Nanshan Shenzhen, ChinaTel: +86 (0) 755 8619 3164Fax: +86 (0) 755 8619 3165 Email: [email protected]
SUTO iTEC (ASIA) Co. Limited
Room 10, 6/F, Block B, Cambridge Plaza 188 San Wan Road, Sheung Shui, N.T. Hong KongTel: +852 2328 9782Fax: +852 2671 3863Email: [email protected]