Page 1: HEATING | FLOOR | SCREED · ThermoSphere screed heating cable is designed for use in 40 - 100mm screed layers. In screed heating systems are ideal for new build projects where floor

HEATING | FLOOR | SCREED

Excellence in heating solutions.

Page 2: HEATING | FLOOR | SCREED · ThermoSphere screed heating cable is designed for use in 40 - 100mm screed layers. In screed heating systems are ideal for new build projects where floor

HEATING | FLOOR | SCREED

2

Perimeter insulation foam acts as a thermal break and expansion gap around the screed

Twisted Twin heating cable

Heavy duty heating cable designed for use in screed

Hard wearing in screed heating cable with advanced protection

Pre spaced galvanised fixing profile for secure cable installation

ThermoSphere screed heating cable is versatile and designed for installation in the screed layer of new builds or renovation projects. It creates a convenient heating system by warming the screed slab as a slow release thermal mass which allows freedom of choice of floor finish at a later stage in the project.

10 YEARWARRANTY

ThermoSphere screed heating solutions are covered by our 10 year warranty for total peace of mind.

Page 3: HEATING | FLOOR | SCREED · ThermoSphere screed heating cable is designed for use in 40 - 100mm screed layers. In screed heating systems are ideal for new build projects where floor

HE

AT

ING

| FL

OO

R | S

CR

EE

D

3

Robust, hard wearing cable

The advanced protective PVC coating on ThermoSphere screed heating cable protects the heating element during installation and provides a long product life span.

In screed heating

Suitable for installation in concrete screeds of 40mm to 100mm. For optimum efficiency, cables should be fixed to foil faced insulation boards before screeding.

Efficient storage heating effect

In screed systems have a slower heat up and cool down time and are suited to rooms that are in constant use. Take advantage of cheaper low cost energy tariffs such as off peak Economy 7 by heating up the floor construction during off peak times.

Primary or secondary heating

ThermoSphere screed heating cable is suitable for both primary and supplementary heating applications, in insulated properties.

Flexible cable spacing

The heating output per m² can be adjusted by varying the cable spacing to achieve your designed heating output.

ThermoSphere screed heating cable is designed for use in40 - 100mm screed layers.

In screed heating systems are ideal for new build projects where floor height is not an issue. ThermoSphere screed heating cable allows you to construct floor surfaces than can be finished later in the project allowing you freedom of choice in floor covering.

Page 4: HEATING | FLOOR | SCREED · ThermoSphere screed heating cable is designed for use in 40 - 100mm screed layers. In screed heating systems are ideal for new build projects where floor
Page 5: HEATING | FLOOR | SCREED · ThermoSphere screed heating cable is designed for use in 40 - 100mm screed layers. In screed heating systems are ideal for new build projects where floor

HE

AT

ING

| FL

OO

R | S

CR

EE

D

5

Engineered timber or laminate floor finish

40-100mm sand and cement or flow screed

ThermoSphere screed heating cable

Fixing profile or staples

Substrate insulation layer

Sub floor

Compatible with ThermoSphere SmartHome Control

A heated concrete screed can be covered with almost any floor finish, subject to manufacturers’ guidelines on maximum floor temperatures.

Our recommended solution

SHC-B-01

SHC-W-01

Page 6: HEATING | FLOOR | SCREED · ThermoSphere screed heating cable is designed for use in 40 - 100mm screed layers. In screed heating systems are ideal for new build projects where floor

6

HEATING | FLOOR | SCREED

Fixing optionsThermoSphere screed heating cable can be fixed in position with one of two fixing methods.You can use the cable staples and tacker gun to fix to foil faced insulation or use the galvanised fixing profile for installing onto other substrates.

Screed cable fixing profileA 25m roll of galvanised steel fixing profile. Can be mechanically fixed to timber or concrete substrates.

Screed cable staple and gunFor easy installation onto foil faced insulation boards with 8mm staples.

SC-STA-0600

Useful calculations

1. How much heating cable do I need?Calculate your total heated area and multiply by the heat output required (eg 120W/m²). Then choose the relevant cable from the list.

Example: 21m² x 120W/m² = 2520W required.

Therefore choose the 144Lm cable (2600W).

2. How many staples do I need?Allow 4 staples per linear metre of cable

Example: 144Lm x 4 = 576 staples

3. How much fixing profile do I need?Cable Lm / 6 = Lm of fixing profile required.

Example: 144Lm / 6 = 24Lm of fixing cable for cable stock code 3062 (144 Lm)

4. How do I work out my cable spacing?Take the total heated area (m²) and multiply by 100. Then divide by the length of cable you have chosen. This gives you your cable spacing in cm.

Example: 21m² x 100 / 144Lm = 14.5cm.

Please note: The lower the output per m², the greater the cable spacing will be.

ThermoSphere do not recommend spacing further than 15cm or closer than 5cm.

Page 7: HEATING | FLOOR | SCREED · ThermoSphere screed heating cable is designed for use in 40 - 100mm screed layers. In screed heating systems are ideal for new build projects where floor

HE

AT

ING

| FL

OO

R | S

CR

EE

D

7

ThermoSphere screed cable can be controlled with any ThermoSphere control, for installations with an Economy 7 energy tariff, we recommend a manual control to switch the heating on and off in conjunction with the floor temperature sensor.

ThermoSphere screed heating cableSelect a cable that provides the required heat output based on the calculations and your desired heat output per sqm opposite.

Stock Code Description Length (m) Output (W) Resistance (Ω)

SC-011-0200 Screed Cable 200W 11.0 200 264.5

SC-016-0300 Screed Cable 300W 16.5 300 176.3

SC-022-0400 Screed Cable 400W 22.0 400 132.2

SC-027-0500 Screed Cable 500W 27.5 500 105.8

SC-033-0600 Screed Cable 600W 33.0 600 88.2

SC-039-0700 Screed Cable 700W 39.0 700 75.6

SC-045-0850 Screed Cable 850W 45.0 850 62.2

SC-055-1000 Screed Cable 1000W 55.0 1000 52.9

SC-069-1250 Screed Cable 1250W 69.0 1250 42.3

SC-076-1375 Screed Cable 1375W 76.0 1375 38.5

SC-094-1700 Screed Cable 1700W 94.0 1700 31.1

SC-116-2100 Screed Cable 2100W 116.0 2100 25.2

SC-144-2600 Screed Cable 2600W 144.0 2600 20.4

SC-183-3300 Screed Cable 3300W 183.0 3300 16.0

Installation accessories

Stock Code Description Size Unit

SC-STA-0600 Plastic Cable Staple 8mm (4 per lm) Pk 600

SC-STG Tacker Gun Ea

SC-GFP-025 Screed Cable Fixing Profile 20mm x 25m Roll

PIF-80-050 Perimeter Insulation Foam 5mm x 80mm x 50m Roll

SCM-W-01 Manual Thermostat Ea

Page 8: HEATING | FLOOR | SCREED · ThermoSphere screed heating cable is designed for use in 40 - 100mm screed layers. In screed heating systems are ideal for new build projects where floor

8

HEATING | FLOOR | SCREED

Your fixing strips should be laid at a right angle to your Thermoduo cable and spaced in intervals approx 0.75m apart.Install 2 floor temperature sensors within a conduit at this point

Starting from a corner, roll the insulation around the perimeter of the room. Also insulate all pipes and fixed obstacles.

This allows the screed to expand and contract when heated. Failure to allow for this expansion could result in a breakage in the screed.

You can simply screed directly over ThermoSphere screed heating cable but take extra care not to damage the yellow cable in any way. Screed over the floor in accordance with industry standards and manufacturer guidelines.

Allow the screed to fully cure before switching your new ThermoSphere screed heating cable system on.

Always follow screed manufacturer’s guidelines.

Starting from the position of your thermostat to lay your ThermoSphere cable. The cable should run at 900 to the fixing profile. It is essential to have an even 50mm (absolute minimum)spacing between each run of cable to ensure even distribution of heat.

Lay fixing profile

Perimeter insulation Screeding your system

Lay cable from the thermostat position

1 2

3 4

Installation overview

Page 9: HEATING | FLOOR | SCREED · ThermoSphere screed heating cable is designed for use in 40 - 100mm screed layers. In screed heating systems are ideal for new build projects where floor

HE

AT

ING

| FL

OO

R | S

CR

EE

D

9

Install the cable the width of your installation area in one run.

Extend each run as it widens laying a new fixing profile with each new area.

Use smaller sections of fixing profile to secure the cable where required.

Use smaller sections of fixing profile to secure the cable where required.

Standard areas Staggered areas Angled areas Avoiding obstacles

Foil faced installation is recommended before installing the cable. Use the galvanised fixing profile to hold the cable in place.Minimum spacing of 50mm should be observed.

Always install a floor temperature sensor in a conduit. An extra floor sensor is recommended.

Foil faced installation is recommended before installing the cable. Use the staples to hold the cable in place.Minimum spacing of 50mm should be observed.

Always install a floor temperature sensor in a conduit. An extra floor sensor is recommended.

Concrete Slab or Block & Beam Concrete Slab or Block & Beam

Floor finish Floor finishFixing profile Staples

Screed ScreedFoil faced insulation Foil faced insulation

ThermoSphere screedheating cable Cable

ThermoSphere screedheating cable Cable

Concrete substrate Concrete substrate

! !

Fixing profile installation Cable staple installation

1 1

6 6

5 5

4 4

2 2

1 1

3 3

4 4

2 25 5

3 36 6

Cable layout options

Page 10: HEATING | FLOOR | SCREED · ThermoSphere screed heating cable is designed for use in 40 - 100mm screed layers. In screed heating systems are ideal for new build projects where floor

10

CONTROL | TOUCH | SINGLE

Manual

Simple on/off switch

Temperature control

Easy to use touch display

Ambient & floor temperature sensing

Stock Code Colour Size (mm) IP Rating Max Load

SCM-W-01 White Glass 85 x 85 x 46 (31mm in wall) IP30 16A

SCM-B-01 Black Glass 85 x 85 x 46 (31mm in wall) IP30 16A

SCM-B-01

SCM-W-01

Technical data

Supply voltage 230V 50/60Hz

Maximum load 16A (3600W)

Temperature range 5 ~ 80°C (0.5°C increments)

Accuracy ±0.5°C

Sensor rating NTC 10kΩ @ 25°C

Consumption 2W

Warranty 3 years

Protection rating IP30

Width 85mm

Height 85mm

Depth 46mm (31mm in wall)

Box contents

1 x Manual Control

1 x Installation guide

1 x 3m floor temperature sensor probe

1 x 2m sensor conduit

2 x Fixing screws

ThermoSphere manual control8

5

50

17 3185

Page 11: HEATING | FLOOR | SCREED · ThermoSphere screed heating cable is designed for use in 40 - 100mm screed layers. In screed heating systems are ideal for new build projects where floor

CO

NT

RO

L | T

OU

CH

| SM

AR

TH

OM

E

11

Stock Code Description Wifi Colour Size (mm) IP Rating Max Load

SHC-W-01 SmartHome Control Yes White 87 x 87 x 14 IP21 16A

SHC-B-01 SmartHome Control Yes Black 87 x 87 x 14 IP21 16A

SHH-01 SmartHome Hub Yes White 95 x 95 x 20 IP30

ThermoSphere SmartHome controls that work with Alexa

SHH-01

Works with Alexa via the ThermoSphere SmartHome Hub

7 day programmable underfloor heating schedule

Tracks your energy use to help save money

Can be used as a standalone electric underfloor heating thermostat

Control from anywhere with the ThermoSphere iOS & Android app

Wireless connection requires:

• Thermosphere Smarthome Hub

• Thermosphere Smarthome control

• Broadband internet

• An available port on your router

• Thermosphere app on a compatible iOS or Android device

• Approximate range limit 20m open field

• Amazon Echo device required for Alexa voice control

ThermoSpherecloud

Alexacloud

AmazonEcho

App

Router Hub

ThermoSpherecontrols

°C °C

°C

SHC-B-01

SHC-W-01

CONTROL | TOUCH | SMARTHOME

Page 12: HEATING | FLOOR | SCREED · ThermoSphere screed heating cable is designed for use in 40 - 100mm screed layers. In screed heating systems are ideal for new build projects where floor

TS_S

B_H

FS01

Excellence in heating solutions.

0800 019 [email protected]

ThermoSpherePattenden LaneMardenKentTN12 9QJ