Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used...

16
Heating REFERENCE GUIDE Experience Our Innovation

Transcript of Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used...

Page 1: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

Heating

REF

EREN

CE

GU

IDE

Experience Our Innovation

Page 2: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

CONTENTS02 Introduction

04 RangeOverview

sElEctIng tHE rIgHt HEatEr

06 Heaterselector

07 Importanttips

FEaturEs

08 Genericheatingfeatures andfunctions

sPEcIFIcatIOns

10 PortableHeaters

11 FluedHeaters

12 GasLogFlameFires

FluEIng

13 AspirationGasLogFlameFire SymmetryGasLogFlameFire

14 RoyaleGasLogFlameFire SlimfireGasLogFlameFire

15 SapphireGasLogFlameFire Energysaver®PowerFlueing

OtHEr

16 Service&WarrantyISO 9001 Lic 4983

SAI Global

N10378

Experience our Innovation

For 40 years Australians have been enjoying the comfort, convenience andreliabilityofRinnaigasappliances.Ourinnovativeproductsaredesignedwiththeenvironmentinmind,withlowemissiontechnologyandhighefficiencies,aswellasahostofothergreatfeatures.

Rinnaiiscommittedtoongoinginnovation-deliveringefficient,welldesignedand engineered lifestyle solutions offering a host of benefits includingambience,versatility,controlandreliability.Backedwithextensivewarrantiesandaftersalesserviceteams,RinnaiisproudtobetheNo.1choiceforgasspaceheatinginAustralia

Throughinnovation,wewillendeavourtocontinueofferingsuperiorrangesofhome appliances that provide a clear insight into what the future holds forAustralianhomes.

About this BrochureThis‘HeaterReferenceGuide’ is tobeused inconjunctionwiththeconsumerbrochure.Thecontentsofthisbrochurearemoreofatechnicalnatureandithasbeen produced in relevant technical sections rather than by specific productpagesasintheconsumerbrochure.

ItisdesignedtobeaquickreferenceguidetoquestionsthatmaybeaskedtoensureselectionofthecorrectRinnaiheatingapplianceforanapplication.Ifyouneedtofindadimensionyougotothespecificationtables,ifyouneedtofindwhataspecificfeatureis,yougotothefeaturesandfunctionspageswhereallfeaturesofallheatersarelisted. Need additional help?PleasecontacttheRinnaiHelpLineon1300555545MondaytoFriday8.00am–5.30pmEST Associations & Certificates

Page 3: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

Energysaver® 559F

Page 4: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

Range Overview - Portable Heaters

PortableHeatersareahighlyefficientlowcostandflexiblehomeheatingalternative.Theyrequirenoinstallationandcanbestoredawaywhennotused.Thereare3formsofheatingavailable-Radiantheat,ConvectionheatandcombinedRadiantandConvectionheat.

HANDYHINT

Best positioned away from you for most comfortable operationCool to touch cabinet allows it to be positioned closer to furnitureFan assisted warmth circulates around the room

Convectors• Convectionheat• Advancedlowemissionburnertechnology• Fullythermostaticset’n’forgetoperation• Easytouseasamanualorprogrammableappliance

HANDYHINT

Must be positioned closer to you as there is no fan Needs to be kept away from furniture

Radiants• Radiantheat• Idealforspotheating-feelthewarmth• Simplebatteryignition-noneedforapowerpoint• Simple&easytooperatemanualsettings

HANDYHINT

Best of both heating types - Radiant & Convected warmthCirculates heat throughout your room

Radiant Convectors• RadiantandConvectionheating• Highefficiencypowerfulheaters• Easyoperation-manuallyadjustableforcomfort

Important Installation Guidelines - Portable Heaters

TheinstallationofPortablegasheatersisrestrictedinsomeStatesofAustralia.Restrictionssometimesinclude:

• Minimumroomsizing(volumeofroomincubicmetres)• Minimumventilationrequirements• Limitedtoacertaingastype(VictoriaLPGonly)• Maximumheatersize18MJ’sonNaturalGasand25MJ’sonLPG(SouthAustralia)• Maximum2.5ng/JNO2emissions(Victoria)• Notpermittedinnewinstallations/homes(Victoria)

Someotherkeypointsthatshouldbenotedinclude:

• Portablegasheaterscannotbeinstalledinbedrooms,bathroomsorhallways• Thegashose&powercordcannotbepositionedthroughadoorwayintoanadjoiningroom• PortableheaterscannotbeoperatedfromanLPGgascylinderinthesameroom• ItshouldbenotedthatminimumroomsizingvariesbetweenthermostaticallycontrolledConvectorsand

manuallycontrolledRadiantheaters• Allinstallationofbayonetpoints,roomsizing&ventilationistobeinaccordancewiththeAustralian

StandardAS5601–GasInstallations

04

rang

e O

verv

iew

- Po

rtab

le H

eate

rs

Page 5: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

Range Overview - Flued Heaters

FluedHeatersutiliseflueingtoensuretherearenoindooremissions.Theycanofferpowerfulheatoutputandtherearemanyenergyefficientproductvarieties.Fluedheatersutilise2formsofheating-ConvectionheatorRadiantandConvectionheat.

HANDYHINT

Sizing is really only critical if the Gas Log Fire is the primary heating source. If required for a decorative look only – select a model with a Flame feature only or Flame Override button

Gas Log Flame Fires• RadiantandConvectionheat• Powerfulheatersthatenhancethefeelofahome• Varietyofstylesandflueingoptions• Freestanding,Inbuilt&FalseFireplaceoptions

HANDYHINT

Great option for those who are sensitive to air qualityHumidifier tray offers the ability to enhance indoor air comfort

Energysavers• Convectionheat• Highlyenergyefficientwithfullset’n’forgetoperation• Powerful‘room-sealed’heatersforoptimumindoorairquality• Rangeofsizeswithflexiblepowerflueinstallationoptions

HANDYHINT

Offer cosy radiant warmth whilst still providing the benefit of convected heat. Ideal for replacement of older space heaters – easy changeover

Flued Space Heaters• RadiantandConvectionheat• Powerfulheatoutputinboththermostaticormanualoperationmodels• Suitsstandard‘offtheshelf’flueing–suppliedbytheinstaller

Important Installation Guidelines - Flued Heaters

AllFluedgasheatersmustbeinstalledbyalicensedplumber/gasfitter.

OtherguidelinesforFluedheatersinclude:

• ItismandatorytouseRinnaiproprietaryflueingforallRinnaiEnergysaver®&GasLogFlameFireheaters.Useofunauthorisedflueingwillnotonlycompromiseperformanceandvoidwarranty,butcouldhaveserioussafetyrelatedconsequences

• All Flued Space Heaters (Ultima II, Spectrum & 2001) use standard ‘off-the-shelf’ flueing componentssuppliedbytheinstaller

• Roomsizingisonlydependantontheheatloadrequired• Ifindoubt,itisbesttoslightlyoversizeaFluedHeaterandletthethermostatdoitswork• InstallationofFluedHeatersislimitedtotheflexibilityoftheflueingsystemandthereforeheaterscannot

alwaysbepositionedwheredesired• Some States of Australia require that a certificate of compliance is given to the end-user for both new

andchangeoverinstallations• AllinstallationsofFluedgasheatersmustcomplywiththeAustralianStandardAS5601–GasInstallations

05

rang

e O

verv

iew

- Fl

ued

Hea

ters

Page 6: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

step 1 climate

Pictured on the right is a climatemap of Australia that shows fourwinter climate zones relevant toRinnai Heaters; Mild, Cool, ColdandVeryCold.Itisimportantthatyouchoosethecorrectzonethatsuits an application, as it directlyrelates to the performance ofthe heater. Detailed State mapscan be found on the ‘heaterselector’ page of our website:www.rinnai.com.au.

step 2 heating area

It is also important that youconsider the size of the heatingarea. This includes adjacentrooms through permanentlyopen doorways and hallways.Onpages10-12 youwillfindtheapproximate maximum area thatthe unit will heat based on theclimatezones(ie.Step1).

step 3 heat loss

Notallhomes willhaveallof thefeatures listed in the table tothe right. Consequently, this willaffect the heating capacity. Placea alongside each of the designfeatures if they are relevant toyourhome.Everywherethereisa

,anadjustmenttothe‘Heatsupto’capacitywillneedtobemade.

Pleasenotethatthisisonlyaguideandindividualhousedesignsandlocationsmayvary.

ContacttheRinnaiHelplineifyourequirefurtherassistance1300555545.

calculate on-line in 3 easy steps

As an example, you wish to purchase a Slimfire gas log flame fire, live in the ‘Cool’ zone, and have an area to heat of 65m2. The recommended ‘Heats up to’ capacity for this model is 68m2, however you also have no carpets on the floor and a house built on stumps. The heat loss total percentage is -10% (-5% + -5% = -10%) which is deducted from the 68m2 (the capacity of your heater) as a % to reduce it to 61m2. This will no longer heat your desired 65m2. The next model up is the Royale Inbuilt with a ‘Heats up to’ capacity of 93m2, less the 10% heat loss = 84m2, which will adequately heat the area.

Your area should be less than the Adjusted Capacity

Calculate your selected Rinnai Heater’s Capacity

1. Selected Heater4. ‘Heats up to’ Capacity(see specifications)

2. Climate/Zone5. Less Heat Loss (see specifications)

3. Total area you are going to heat (length x width)

6. Adjusted Capacity

m2

m2

m2

%

Heat Loss Factors Deduct Example

No Ceiling Insulation -10% ______ %

House built on stumps (not a slab) -5% ______ % -5%

No carpets on floors -5% ______ % -5%

No drapes on windows -5% ______ %

Uncurtained window area exceeding 15.0m2 -10% ______ %

Ceiling height exceeding 2.4m

If Yes, height 2.5 - 2.8m -3% ______ %

2.8 - 3.0m -5% ______ %

3.0m + -7% ______ %

Reversible Ceiling Fan (positive) +5% ______ % ______

HEAT LOSS FACTOR TOTAL ______ % -10%

Page 7: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

Energy Star RatingsEnergyStarratingsareanindustrywideindependentratingthatgivesanindicationofhowefficientlyaheateroperates...themorestarsthegreatertheefficiency.TypicallyPortablegasheatershavearound5.9Starswiththemajorityoffluedheatersaround4.0to4.5Stars.Someoldertypeheatersarenot as efficient, however they still perform extremely wellwithlargeheatoutputs.

The EnvironmentInAustralianhomes,heating&coolingamountstoaround23%ofhouseholdenergyuse–secondonlytohotwater.Gas is one of the most greenhouse friendly fuel sourcesavailable and selection of a Rinnai gas heater can assistwith our global need to reduce carbon emissions. Inaddition,thebetterinsulatedyourhome,thelessworktheheaterneedstodo,thelessgasyouwilluseandthelessimpactontheenvironment.

Very Cold Zone: 1kWoutputwillheatapprox8.5m2

Cold Zone: 1kWoutputwillheatapprox10m2

Cool Zone: 1kWoutputwillheatapprox13m2

Mild Zone: 1kWoutputwillheatapprox16m2

i.e. a 7.3 kW output heater in a Cool Zone will heat approx 95m2

Running Costs

Rinnaigasheatersaredesignedtobehighlyefficient,andwhenusedcorrectly,areaveryeconomicalformofhomeheating.Therunningcostofgasheaterscompareverywelltootherformsofheating.Straightelectricheatingisbyfarthemostexpensive,withbothgasheatersandelectricreversecycleheaterscomparativelylessexpensive.

Whencomparingdifferingformsofheatinginrelationtorunningcosts,itisimportantthatthecomparisonisbasedonthesamekWoutputofheat.Oncewearecomparing‘appleswithapples’,thecalculationoftherunningcostisthenbasedontheenergyused(kWinput)toachievethatoutput.Theactualtariffsthatarechargedarelistedonenergybills.

Heating Sizing Itisveryimportantthatcarefulconsiderationisgiventoselectingthecorrectmodel/sizeofanyheater.Criticalfactorssuchastheareatobeheated,alongwithspecificdesignandinsulationcharacteristicsofahomemustallbeconsidered.Ontheoppositepagethereisaheaterselectorrelatingtocorrectsizingoryoucanuseouron-lineversionatwww.rinnai.com.au.

IngeneralheatersizingshouldbebasedonthekWoutputoftheheater.Asaveryroughguidetoheatingperformance(basedonourheatingzones):

07

Impo

rtan

t tip

s

KitchenAppliances

10%

Comparison of Energy use around the home

Fridge Other Heating&Cooling

HotWater

12%18% 23%

37%

Source: Department of Environmental & Climate Change NSW

Important Tips for heater selection

HANDYHINT

The MJ input of heaters should not be used for comparison. The kW output is the only true ‘apples for apples’ method.

As an example, a 25MJ input, 5.9 Star heater has a larger heat output than a 25MJ 3.1 Star heater.

Page 8: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

Generic Heating Features & Functions

TherearemanydifferingfeaturesthatareavailablewithRinnaigasheatingappliances.Thefollowingpagesgiveanoverviewofeachfeature,thebenefitsgainedandabriefexplanationofhowtheywork.Foraspecificlistofwhichfeaturesapplytoaparticularproduct,pleaserefertothespecificationsstartingonpage10.

Preheat FeatureThisfunctionwillautomaticallyoperatetheappliancebeforetheprogrammedstarttime of the timer, in order to heat a room to the pre-set temperature by theprogrammedstarttime.Thismeansthattheheatermayactivateupto1hourpriortotheprogrammedstarttime.

Economy ButtonTheEconomy(ECON) function isanenergysavingfeature. Itgradually reducestheheat settings once the room has maintained the set temperature for a period of 1hour.Manypeopleoperateheatersatahighertemperature initiallywhentheyarecold,butforgettoturnthemdownlater.

Delay OFF TimerThisisalsoacountdowntimerbutthesetperiodisfixedateither30or60minutes.Onceactivatedtheheaterwillautomaticallyshutoffafterthisperiod.Typicallyusedinthemorningswhenpeoplegetoutofbed,itensuresthatiftheyrushoutthedoortheywon’tleavetheheateronallday!

Delay Timer (FDT) This feature isonlyavailablewiththe“FDT”rangeofEnergysaverPowerFluedheatersand isusuallyonlyusedforcommercialapplicationsuchasschoolsetc.Factoryordered&preset,thedelaytimerautomaticallyshutstheheateroffafterapredetermined(programmed)timeofeither1,2,3,6,8,10or12hourintervals.Asanadditionalfeature,acentralrelaytimercanbeprogrammedtooperatemultipleheaters.

Please contact Rinnai on 1300 555 545 for further information on Delay Timer (FDT) programming

Thermostatic Heat ControlOften referred to as set’n’forget, thermostatic control means that the heater will modulateupanddowntoensureasettemperatureismaintained,forgreatercomfort.

Manual Heat ControlThisappliestoheatermodelsthathaveanumberofpredeterminedsettingsthatyoucanselectfrom.SomeheatershaveaLow/Med/Highoptionwhileotherscanhaveupto6manualsettings.

TimersModelswithtimershaveoneofthefollowing:

Dual Weekday & Weekend TimersSet the heater to come on and off in the mornings & evenings for the weekdaysMonday to Friday. Additionally, different times can be set for the weekend whenpeopleprefertogetupalittlelater.

Dual TimersSettheheatertocomeonandoffinthemornings&evenings(oranyotherselecteddualperiods).Timersaresetseparatelyallowingyoutooperatewithboth,justoneornoneatall.

Multiple Timers (4 Periods)Where4periodsperdaycanbesetatvaryingtemperatures.Idealformorningswhenwaking and coming home of an evening, with the other 2 periods usually set as aminimumdesiredtemperatureduringthedayandovernight.Inaddition,eachdayoftheweekcanhaveadifferentsetting,makingthesetimersthemostflexibleavailable

Delay ON TimerThisisacountdowntimerthatallowsyoutoselectinhowmanyhours/minutesyouwishtheheater toswitchon. Itallowsyoutoselectupto9½hours in30minuteincrementsorupto24hoursin60minuteincrements.DelayONtimeristypicallysetbeforegoingtobedandwhenleavinginthemorningtocomeonwhenyougetupandreturnfromwork.

08

Feat

ures

Page 9: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

Auto Off ButtonThe auto-off feature found on some of our Gas Log Flame Fires, Energysavers® and Space Heaters is only relevant when theminimum heat setting of the heater still has too much heat output to maintain the set temperature. If the auto-off button isactivated,theheaterwouldturnoffratherthancontinuetoheattheroomabovethesettemperature.Insimpleterms,theauto-offneedstobeactivated(displayed)inorderfortheheatertobefullythermostaticallycontrolled.

Override ButtonTheoverridebuttonisonlyusedwhenaheaterhasprogrammedtimersset.Itallowsyoutomanuallyactivatetheheateroutsideoftheprogrammedtimeswithoutdisruptiontothesettings(i.e:ifsomeonecomeshomeearlyfromwork/school).

Flame ButtonTheFlamebuttonisonlyfoundonselectedGasLogFlameFiresanditallowstheusertooverridethethermostatandmaintainsaconstantflamepicture.Basicallyitisusedwhenjusttheambienceofafireisrequired.

Lockable PanelThe commercial Energysaver® FDT modelshaveakeylockablecontrolpanellid.Thisisprimarilytoensurethatprogrammedtimesand/or temperature settings are notadjustedbythepublic.

Filter Indicator LightWhenthefanfiltersbecomecoveredwithdust,thefilterindicatorwillflash.Thefiltersonallheatersshouldbevacuumedatregularintervalstooptimiseheatingeffectiveness.

Child Lock or Lock ButtonAfeaturethatensuresthatlittlewanderinghandscannotactivateorplaywiththeheater.IfthelockisactivatedwhentheapplianceisturnedOFFthenallfunctionsarelocked.Ifthelockisactivatedwhentheheaterisinoperation,thenonlytheOFFbuttonwillfunction.Therearetwotypesofchildlockactivations:

1. Singlebuttonwhichmustbehelddownforabout3secondsuntilthereisabeep

2. Somemodelsrequiretheusertopush2buttonssimultaneouslytolockandunlockthefeature

Eithermethodisdifficultforyoungchildrentoaccidentlyactivate.

Additional Safety features

Over heat switchWhentheheatergetstoohotduringoperation(forexamplewhenthefiltersorairoutletlouvresareblocked)thisdeviceturnsthegasoffautomatically

Flame failure sensorThisdeviceautomaticallycutsoffthegassupplytotheheaterintheeventofagasfailure

Oxygen depletion sensorIftheoxygenlevelintheroomdropsbelowapre-setlimit,thisdevicecutsthegassupplytotheheater.Thisfeatureisstandardwithallportableheaters.

Tilt switchOnly found on portable heaters, the tilt switch will immediately cut the gas supply if the heater is accidentallyknockedover.Foradditionalsafety,thefanwillcontinuetooperateensuringtheheateriscooledaswell.

Power failureIntheeventofapowerfailureorpowercut,thegasvalvesonthermostaticmodelswillautomaticallycloseandshutoffthegassupply.

09

Feat

ures

Page 10: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

Model

avenger 25Plus (Gas&

Electric)

capella 18Plus (Gas&

Electric)

avenger 25 Dynamo15

Enduro 13 Econoheat 850

cosyglow650

granada 252

titan 151

Dimen-sions (mm)

H 570 570 485 495 495 410 405 540 540

W 610 610 610 490 490 505 440 620 620

D 245 245 245 245 245 250 250 220 220

colours WhiteorPlatinumSilver PlatinumSilverOffWhiteorPlatinum

Silver

gas type AvailableinbothNaturalGasandLPG

low nOx Yes Yes Yes Yes Yes No No No No

gas Hose length (mm) 1500

Electric cord length (mm) 1500 Nocord 1500

gas Input MJ/h

low 8.5 8.5 8.5 6.0 6.0 7.0 5.5 8.0 7.5

High 25 18 25 15 13 15 11 25 15

kW Output 8.2 6.6 6.2 3.8 3.3 3.5 2.9 6.0 3.7

‘Heats up to’ capacity (m2)

Very cold 70 55 53 32 28 31 23 52 31

cold 83 66 63 38 33 35 28 57 34

cool 113 89 85 52 45 47 37 76 46

Mild 128 102 97 59 51 54 42 87 53

as4553 Efficiency star rating

5.8 5.8 5.8 5.8 5.8 5.9 5.9 5.9 5.9

as4553 Emissions star rating ng/lPg

3.8/3.5 4.6/4.1 3.8/3.5 3.8/3.5 3.6/3.5 2.8/3.0 2.1/2.1 2.3/2.5 2.0/1.6

thermostatic or Manual control

ThermostaticManual

2SettingsManual

2SettingsManual

3SettingsManual

2Settings

Dual Weekday & Weekend timers

Yes Yes

Dual timers Yes Yes

Delay On timer Yes

Delay OFF timer (60 Minute)

Yes

Preheat Feature Yes Yes Yes Yes

Economy Mode Yes Yes Yes Yes Yes

auto Off Mode Yes Yes

Override Button Yes Yes Yes Yes

child lock or lock Button

Yes Yes Yes Yes Yes

240VpowerisrequiredwithallmodelswiththeexceptionofRadiantonlyheaters.Apowercord&plugarefitted.Dimensionsaresubjecttoproductiontolerancesandmayvaryslightlyfromthosegiven.RinnaiAustraliaPty.Ltd.Reservestherighttomakemodificationsandchangespecificationswithoutnotice.Wewillhoweverendeavourtocommunicateanymajorchangeswellbeforeimplementation.

Portable Heating Specifications

10

spec

ifica

tions

- Po

rtab

le H

eate

rs

Page 11: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

Flued Heating Specifications

Model

Energysaver® ultima II 2001 spectrum

309F

t

556F

Dt

559F

t

557F

tr

1004

Ftr

1004

FDt

Inbu

ilt

cons

ole

Inbu

ilt

cons

ole

Inbu

ilt

cons

ole

Dimen-sions(mm)

H 695 554 582 750 670 670 653 653 650 650 650 650

W 465 750 760 550 930 930 910 910 910 910 910 910

D 257 250 257 250 330 330 164 404 125 302 125 302

InbuiltCavityDimen-sions(mm)

H - - - - - - 605-635 - 605-635 - 605-635 -

W - - - - - - 710-805 - 710-805 - 540-805 -

D - - - - - - Min.330 - Min.270 - Min.270 -

Colours White White WhiteWhiteor

SilverWhite

BeigeorGunmetal

BeigeorBrown

GasType NG/LPG NGOnly* NG/LPG NG/LPG NG/LPG NGOnly* NG/LPG NGOnly*

GasInputMJ/h

Low 6 9 9 9 11 11 15 15 7

High 13 23 23 23 37 37 30 30 28

kWOutput 2.9 5.4 5.2 5.4 8.6 8.6 7.0 5.2 5.2

‘Heatsupto’Capacity(m2)

VeryCold 27 47 47 47 75 75 59 45 41

Cold 32 56 56 56 89 89 70 53 49

Cool 42 74 74 74 119 119 95 70 65

Mild 49 85 85 85 138 138 109 81 75

AS4553EfficiencyStarRating

4.6 4.3 4.3 4.2 4.3 4.3 4.4 1.0 2.1

AS4553EmissionsStarRatingNG&LPG

6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0

ThermostaticorManualControl

Thermostatic Manual3Settings

DualTimers Yes Yes Yes Yes

DelayTimer(FDT) Yes Yes Yes Yes

DualWeekday&WeekendTimers

Yes Yes

Preheatfeature Yes Yes Yes Yes Yes Yes

EconomyMode Yes Yes Yes Yes Yes Yes

AutoOffMode Yes Yes Yes Yes Yes Yes Yes Yes

OverrideButton Yes Yes Yes Yes Yes Yes

ChildLockorLockButton

Yes Key Yes Yes Yes Key Yes Yes

*LPGconversionsareavailableatanadditionalcostandaremadetoorder240Vpowerisrequiredwithallmodelsandapowercord&plugisfitted.Inmostcasesthiscordisontherighthandside.Tohidethepowercord,itispermissibletohavetheunit‘hardwired’behindwallcavitiesaslongasitisinaccordancewiththeStandardAS/NZS3000anddonebyaqualifiedelectricaltradespersonsuchasanelectrician.Inshort,thismeansthatitmustbewiredwithanaccessibledoublepoleisolationswitch.

Dimensionsaresubjecttoproductiontolerancesandmayvaryslightlyfromthosegiven.RinnaiAustraliaPty.Ltd.Reservestherighttomakemodificationsandchangespecificationswithoutnotice.Wewillhoweverendeavourtocommunicateanymajorchangeswellbeforeimplementation.

11

spec

ifica

tions

- Fl

ued

Hea

ters

Page 12: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

Gas Log Flame Fire Specifications

12

spec

ifica

tions

- g

as l

og F

lam

e Fi

re

Model

aspiration symmetry royale Etr slimfire sapphire

StyleSlimline

MetalRadiusGlass

InbuiltFree-

standingInbuilt Inbuilt Masonry

ZeroClearance

Console Plinth

VisualDimen-sions(mm)

H 675 675 640 755 695 645 660 660 760 837

W 900 900 1110 650 910 750 865 865 865 865

D 90 126 13 560 167 335 462 462 425 425

InbuiltCavityDimen-sions(mm)

H 660 660 845 N/A 595-675 550-630 600 650 N/A N/A

W 860 860 1100-1125 N/A 600-800 595-700 695 800 N/A N/A

D 450* 450* Min600 N/A Min.405 Min.360 370 420 N/A N/A

Colours

MetallicBlackorStainless

Steel

Black BlackMetallic

BlackMetallic

Black

MetallicBlackorStainless

Steel

BlackouterframewithStainlessSteelinnerframe

GasTypes NGOnly# NGOnly# NG/LPG NG/LPG

GasInputMJ/h

Low 8 8 19 8 8 7.7 14 14 14 14

High 31.5† 31.5† 33 35 33 25 30 30 30 30

kWOutput 6.0 6.0 7.5 7.4 6.6 5.0 6.97 6.97 6.97 6.97

‘Heatsupto’Capacity(m2)

VeryCold 47 47 67 66 58 42 60 60 60 60

Cold 56 56 80 79 69 50 70 70 70 70

Cool 74 74 108 106 93 68 95 95 95 95

Mild 85 85 124 122 109 77 108 108 108 108

AS4553EfficiencyStarRating

4.0†† 4.0†† 4.2 2.5 2.6 2.8 4.1 4.1 4.1 4.1

AS4553EmissionsStarRatingNG&LPG

6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0

ThermostaticorManualControl

ThermostaticManual3Settings

Manual/RemoteThermostat*

DualTimers Yes Yes Yes Yes

MultipleTimers(4Periods) Yes Yes,withoptionalremotecontrol

PreheatFeature Yes Yes Yes Yes

AutoOffMode Yes Yes Yes Yes Yes Yes** Yes** Yes** Yes**

OverrideButton Yes Yes Yes Yes

FlameFunction Yes Yes Yes Yes Yes** Yes** Yes** Yes**

ChildLockorLockButton Yes Yes Yes Yes

Please note:#Lpgconversionsareavailableatanadditionalcostandaremadetoorder*Suitablefordirect,verticalorhorizontalflueing.500mmrequiredfordownandoutflueapplications.Seeinstallationinstructionsforfulldetails†31.5MJ/hwheninstalledwithadirectflue.Gasinput28MJ/hwheninstalledwithanextendedflue††4.0Starswheninstalledwithadirectflue.Increasesto5.2Starswheninstalledwithanextendedflueº4.0StarRatingwheninstalledinasoundbrickormasonryfireplacewithoutaflue

240Vpowerisrequiredwithallmodelsandapowercord&plugisfitted.Inmostcasesthiscordisstandardontherighthandsideoftheappliance.TheRoyale&SlimfireFlameFiresalsoallowyoutohavetheelectricalcordoneithertherightorlefthandside.

Tohidethepowercord,itispermissibletohavetheunit‘hardwired’behindwallcavitiesaslongasitisinaccordancewiththeStandardAS/NZS3000anddonebyaqualifiedelectricaltradespersonsuchasanelectrician.Inshort,thismeansthatitmustbewiredwithanaccessibledoublepoleisolationswitch.

Dimensionsaresubjecttoproductiontolerancesandmayvaryslightlyfromthosegiven.RinnaiAustraliaPty.Ltd.Reservestherighttomakemodificationsandchangespecificationswithoutnotice.Wewillhoweverendeavourtocommunicateanymajorchangeswellbeforeimplementation.

Page 13: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

Aspiration Gas Log Flame Fire Power Flueing

*includescondensatetrap#orderlengthsasrequired

Description Order Code

1 DirectFlueKit ASPDFK

2AVertical‘OnWall’Kit*Co-AxPipe900mm#

RoofCowl

ASPKIT03ESPIPE900ESROOFCOWL

2B

Vertical‘OnWall’Kit*Co-AxPipe900mm#

Bend(2x45º)RoofCowl

ASPKIT03ESPIPE900ESBENDESROOFCOWL

3A

DirectFlueKitCo-AxPipe900mm#

Bend(2x45º)CondensateTrapRoofCowl

ASPDFKESPIPE900ESBENDESCONDKESROOFCOWL

3B

DirectFlueKitCo-AxPipe900mm#

2SetsofBends(2x45º)CondensateTrapWallTerminalKit

ASPDFKESPIPE900ESBENDx2ESCONDKESWTKIT

4Vertical‘OnWall’Kit*Co-AxPipe900mm#

WallTerminalKit

ASPKIT03ESPIPE900ESWTKIT

5

Vertical‘OnWall’Kit*Co-AxPipe900mm#

Bend(2x45º)WallTerminalKit

ASPKIT03ESPIPE900ESBENDESWTKIT

FasciasSlimlineMetallicBlackFasciaSlimlineStainlessSteelFascia

Order CodeFLFASPFFBFLFASPFFSS

FasciasRadiusGlassBlackFascia

Order CodeFLFASPFRBG

Installation ClearancesSidesofappliance 100mmAboveappliance 250mmInfront 1000mm

1.

4.

2. 3.

5.

< false wall

< false wall

< false wall

min. 300mm vertical clearance from base of flue terminal

Flueing

13

Flue

ing

Symmetryflueingcombinationsvaryforeachinstallation.Pleaserefertotheinstallationinstructionsoronlineatwww.rinnai.com.au

Symmetry Gas Log Flame Fire

Installation ClearancesSidesofappliance 400mmAboveappliance 400mmInfront 1000mm

TheDirectFlueKitcoversthemajorityofinstallations.Separatecomponentsareavailableforotherinstallationsasshown.

Description

1. DirectFlueKit

Individual Components

90mmFlueLength230mmFluelength300mmFluelength600mmFluelength1200mmFluelength275-370(adjustable)Fluelength90ºElbow45ºElbowHighWind(Roof)TerminalCapSquareHorizontal(Wall)Cap

Order Code

SYMDFK

RDV903RDV907RDV906RDV904RDV902RDV911BRDV990GRDV945GRDV991RDV984

< elevated installation

< direct flue kit installation

1.

Page 14: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

14

Flue

ing

Royale ETR Gas Log Flame Fire

1. 2. 3. 4.

Freestanding Inbuilt

< false wall

< masonry fireplace

zero clearance

Description OrderCode

1A VerticalTwinSkinFlueKit(3.6m) FLFKIT05*

1B VerticalTwinSkinFlueKit(3.6m)TwinSkinOffset

FLFKIT05*FLFBEND*

2

Thru-wallTwinSkinFlueKit(3.6m)inc.1x900mmPowderCoated&3x900mmGalvanisedTwinSkinFlues,Cowl&WallPenetrationKit

FLFKIT03*

3 FlexilinerFlueKit(5.0m) FLEXLINER05

4A VerticalTwinSkinFlueKit(3.6m) FLFKIT05B

4B VerticalTwinSkinFlueKit(3.6m)TwinSkinOffset

FLFKIT05BFLFBENDB

Freestanding Accessories450mmTwinSkinFlue900mmTwinSkinFlue45ºTwinSkinOffset900mmGalvanisedFlueExtTwinSkin

Order CodeFLF0450M*FLF0900M*FLFBEND*FLFEXT03

Inbuilt AccessoriesFlueAdaptorPlate50mmPlinth45ºTwinSkinOffset40mmExternalTopSurround(BlackOnly)

Order CodeFLFADFLFRP*FLFBENDBFLFRSEXTB

ForThru-Walldoublestoreyapplications,pleaseorderthe3.6metreThru-WallTwinSkinKit(FLFKIT03)andadditionallengthsof900mmGalvanisedFlueExtensions(FLFEXT03)asrequired

Installation ClearancesSidesofappliance 400mmAboveappliance 400mmBackofdraftdiverter 100mmInfront 1000mm

Inbuilt Zero Clearance Frame Dimensions(Seeinstallationinstructionsforfulldetails)

745mmHx810mmWx440mmD(min.)MetallicBlackZeroBox ZEROR1

TitaniumZeroBox ZEROR2T

*NominateMetallicBlackorTitanium

Slimfire Gas Log Flame Fire

#NominateMetallicBlackorStainlessSteel

Description Order Code

1 NoFlue N/A

2 FlexilinerFlueKit FLEXLINER03

3A VerticalTwinSkinFlueKit FLFKIT05

3B VerticalTwinSkinFlueKitTwinSkinOffset

FLFKIT05FLFBEND

4 VerticalTwinSkinFlueKitThru-wallTwinSkinFlueKit

FLFKIT05FLFKIT03

Fascias Order CodeMetallicBlackFascia FLFSFBStainlessSteelFascia FLFSFSS

Sided FasciaInspiration3SidedFascia-Duracote INSP3FDInspiration3SidedFascia-Black INSP3FDInspiration4SidedFascia-Duracote INSP4FDInspiration4SidedFascia-Black INSP4FB

MantlesInspirationMantle-Cherry INSPMCInspirationMantle-Beech INSPMB

Accessories Order CodeFlueboxAdaptor FLFAD150mmPlinth(MasonryFireplacesonly) FLFSP#

90mmExtTop3-sidedSurround(Blackonly) FLFSBEXT

Console KitExtendsprotrusionoftheSlimfireby300mm.Kitincludessides,topandbaseplinth.Allothercomponentssuppliedbyinstallingplumber

MetallicBlackConsoleKit FLFSCBStainlessSteelConsoleKit FLFSCSS

Installation ClearancesFromtopofglass 300mmFromsidesofglass 300mmInfront 1000mm

Inbuilt Zero Clearance Frame Dimensions(Seeinstallationinstructionsforfulldetails)

675mmHx685mmWx370mmD(min.)MetallicBlackZeroBox ZEROS

TitaniumZeroBox ZEROS2

zero clearancezero clearance

1. 2. 3. 4.

< false wall

< false wall

< masonry fireplace

zero clearancezero clearance

1. 2. 3. 4.

< false wall

< false wall

< masonry fireplace

Page 15: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

15

Flue

ing

Energysaver® - Power Flueing

*includescondensatetrap#orderlengthsasrequired

Description Order Code

1 DirectFlueKit ESDFK

2

DirectFlueKitCo-AxPipe900mm*WallPlateBackSpacerKit

ESDFKESPIPE900ESPLATESeebelowright

3A

DirectFlueKitCo-AxPipe900mm*90°Bend(2x45°)CondensateTrapRoofCowl

ESDFKESPIPE900ESBENDESCONDKESROOFCOWL

3B

DirectFlueKitCo-AxPipe900mm*2x90ºBends(4x45°)CondensateTrapWallTerminalKit

ESDFKESPIPE9002XESBENDESCONDKESWTKIT

4

DirectFlueKitWallTerminalKitCo-AxPipe900mm*90°Bend(2x45°)BackSpacerKit

ESDFKESWTKITESPIPE900ESBENDSeebelowright

5A

InWallFlueKitIncludes:CondensateTrapRoofCowl4xCo-AxPipe900mm

ESFKITIW

5B

Bends(2x45º)InWallFlueKit Includes:CondensateTrapRoofCowl4xCo-AxPipe900mm

ESBENDESFKITIW

Back Spacer Kits#

Model Colour Order Code

Energysaver308 White ESBSKA

Energysaver556White ESBSKB

PlatinumSilver ESBSKSB

Energysaver557White ESBSKC

PlatinumSilver ESBSKSC

Energysaver1004 White ESBSKD

OptionalFlueGuard FGM01

*Order lengths as required

#A Back Spacer Kit is required in all installations that are either sideways or down and out (2 & 4)

1. 2. 3.

Min. 300mm vertical clearance from base of flue terminal4. 5.

Installation ClearancesSidesofappliance 50mmAboveappliance 300mmInfront 1000mm

Sapphire Gas Log Flame Fire

Description OrderCode

Inbu

ilt

1 NoFlue N/A

2 FlexilinerFlueKit(5.0m) FLEXILINER05

3A VerticalTwinSkinFlueKit(3.6m) FLFKIT05G

3B VerticalTwinSkinFlueKit(3.6m)TwinSkinOffset

FLFKIT05GFLFBENDG

4 VerticalTwinSkinFlueKitThru-wallTwinSkinFlueKit

FLFKIT05GFLFEXT03BG

Free

stan

ding

5A VerticalTwinSkinFlueKit(3.6m) FLFKIT05G

5B VerticalTwinSkinFlueKit(3.6m)TwinSkinOffset

FLFKIT05GFLFBENDG

6 VerticalTwinSkinFlueKitThru-wallTwinSkinFlueKit

FLFKIT05GFLFEXT03BG

Inbuilt Zero Clearance Cavity Dimensions 650mmHx800mmWx420mmD(min.) ZeroBox SAPZEROCLR

1. 2.Inbuilt Masonry

3. 4.Inbuilt Zero Clearance

5. 6.Freestanding (Console & Plinth)

Accessories Order Code450mmTwinSkinFlue FLF0450MG900mmTwinSkinFlue FLF0900MG1200mmx145mmTwinSkinFlue FLFEXT03

RemoteControlAccessory SAPRMSpigotAssembly(ZeroClearance&Freestanding) SAPFSSA

Page 16: Heating · 2015-09-01 · Rinnai gas heaters are designed to be highly efficient,and when used correctly, are a very economical form of home heating. The running cost of gas heaters

Rinnai Service - Need help with installation?

In most situations Rinnai retailers can assist with the installation of our appliances. Should this not be the case, Rinnai has aninstallationserviceavailabledirecttotheend-user.

Any gas installation, and in particular where flueing is also required, is a specialist process and requires trained professionalinstallerstoensuresafeandefficientoperationoftheappliance.OurRinnaiinstallersarenotonlyveryfamiliarwithourproducts,butarefullyinsuredandOH&Scompliant.BeconfidentinyourinstallationbyemployingRinnaiService.

For further information, please call 1300 555 545

Rinnai Heating Products Warranty

DEFINITIONS

Domestic use:Thewarrantyperiodsinthetableabovethatareallocatedunder“DomesticUse”arebasedontheheatingrequirementsofatypicaldomesticdwelling.

Commercial use:Thewarrantyperiodsthatareallocatedunder“CommercialUse”areforapplicationsotherthandomesticuseandincludepremisessuchascommercialandindustrialbuildings,hotels,motels,caravanparks,cafes,schoolsandsportingcomplexes,butnotlimitedtothese.

Fullwarrantyconditionsincludingexclusions,areavailablewitheachapplianceandcanbeviewedonlineatrinnai.com.au

Table 1

Flued Heaters Portable radiant Heaters

Portable convector Heaters

UltimaII,2001Spectrum

Energysaver®AspirationSapphire

RoyaleSlimfire

Symmetry

Titan151Granada252

Cosyglow650Econoheat850

Avenger25Avenger25Plus

Capella18Capella18Plus

Dynamo15Enduro13

Dom

estic

use

HeatExchanger 10yearsprorata(1) 10yearsprorata(2) 10yearsprorata(3)

Fan 2years 3years 5years

Allotherparts 1year 3years 5years

FreeLabour 1year 3years 5years

com

mer

cial

use HeatExchanger 1year 1year 1year

Fan 1year 1year 1year

Allotherparts 1year 1year 1year

FreeLabour 1year 1year 1year

(1)Fullreplacementcostsinthefirstyear,reducing10%peryearthereafter(2)Fullreplacementcostsinthefirst3years,reducing15%peryearthereafter(3)Fullreplacementcostsinthefirst5years,reducing20%peryearthereafter

ww

w.ri

nnai

.com

.au

RINNAI AUSTRALIA PTY. LTD ABN74005138769

10-11WalkerStreetBraesideVIC3195Forfurtherinformationvisitwww.rinnai.com.au or call 1300 555 545 06.11_MAY