Heat Transfer / Hot Oil Systems - Integrated Flow Solutions · Piping Designed to ANSI B31.1/ANSI...
Transcript of Heat Transfer / Hot Oil Systems - Integrated Flow Solutions · Piping Designed to ANSI B31.1/ANSI...
Industries
BenefitsSingle Source AccountabilityPre-Packaged Modular Design Costs Less Than Component Based Site-Built Systems Reducing Overall Project CostMinimizes Field Erection Time -Shorter Overall Project Delivery ScheduleComplete System Function TestingPrior To Shipment24/7 Customer Service
Industry StandardsVessels Code Stamped ASME Section VIII &National Board RegisteredPiping Designed to ANSI B31.1/ANSI B31.3Pipe Fabrication to ASME Section IXStructural Steel Assembly Designed to AWS D1.1
Standard FeaturesSpecial Centerline Mounted or Vertical InlineHigh Temperature Centrifugal Pumps Designedfor Thermal GrowthThermal Pipe Stress Analysis to Prevent PipeRupture & Increase Equipment LifeCellular Glass Insulation for Easy Leak Detectionand Fire Prevention
HTHO-100.0
Integrated Flow Solutions Heat Transfer/Hot Oil Systems aredesigned to store and transfer heat transfer fluids used forindustrial heating. The heat transfer fluid is normally stored inan elevated insulated vessel skid mounted. Special hightemperature centrifugal pumps are used to circulate the heatmedia fluid from the storage tank through an electric processheater, gas fired heater or exhaust heat exchanger. The heattransfer fluid’s elevated temperature is then used to safely heata process system and is then returned to the storage vessel.
Heat Transfer/Hot Oil Systems
Standard Features (Continued)Double Drop and By-Pass Expansion Tank for Venting of Low BoilersINTEGRAHEATTM Electric Process Heaters
Heat Transfer Oils - (15W/In2) To ReduceCoke Buildup and Maximize Oil andHeater LifeWater - (45W/In2) To Minimize Scale Buildupand Maximize Heater LifeTriEthylene Glycol - (12W/In2 - 15W/In2) To Minimize Degradation and ExtendHeater Life
On-Skid Across-the-Line Starting Control PanelWired to Electric Motors
Optional FeaturesMetal Fiber Filters in 5-10% Slip Stream Flowto Prevent Fouling of SystemLadder and Platform for Expansion Tank AccessAir Cooler for Quick ShutdownAPI 610 Centrifugal, Canned Motor or Mag Drive PumpsPLC Control System with Data HighwayIEC/CENELEC/CSA Compliant Control Panel,Conduit and WiringCompliance with Plant/Engineering Specifications
Additional ServicesNationwide Service NetworkInstallation/Training/Start-Up SupervisionEquipment Leasing ProgramExtended Equipment Warranties“Aspen Plus” Process Simulation Software toGuarantee Process Conditions
GENERALPOWER OIL & GAS
www.IFSolutions.com
INTEGRATED FLOW SOLUTIONS 9807 Whithorn Drive Houston, TX 77095 281-855-8125 / Toll-Free USA 800-795-4068
www.IFSolutions.com
Heat Transfer/Hot Oil Systems
INTEGRATED FLOW SOLUTIONS 9807 Whithorn Drive Houston, TX 77095 281-855-8125 / Toll-Free USA 800-795-4068LIT HTHO-100.0 03042004 IFS These materials contain proprietary information and may not be reproduced without prior written permission from Integrated Flow Solutions.
EXPANSION TANK DRY WEIGHTFLOW RATE (GPM) WORKING VOLUME (GALLONS) LENGTH - X WIDTH - Y HEIGHT - Z (LBS.)
50 500 6’ 4’ 12’ 2,000100 1,000 6’ 8’ 14’ 4,000200 2,000 8’ 10’ 16’ 8,000300 3,000 12’ 10’ 18’ 12,000500 5,000 20’ 10’ 20’ 20,000
P L A N V I E W E L E V A T I O N V I E W
"Y" O
VE
RA
LL S
KID
WID
TH
"X" OVERALL LENGTH
"H" O
VE
RA
LL S
KID
HE
IGH
T
www.IFSolutions.com