Heat Transfer / Hot Oil Systems - Integrated Flow Solutions · heater, gas fired heater or exhaust...

2
Industries Benefits Single Source Accountability Pre-Packaged Modular Design Costs Less Than Component Based Site-Built Systems Reducing Overall Project Cost Minimizes Field Erection Time - Shorter Overall Project Delivery Schedule Complete System Function Testing Prior To Shipment 24/7 Customer Service Industry Standards Vessels Code Stamped ASME Section VIII & National Board Registered Piping Designed to ANSI B31.1/ANSI B31.3 Pipe Fabrication to ASME Section IX Structural Steel Assembly Designed to AWS D1.1 Standard Features Special Centerline Mounted or Vertical Inline High Temperature Centrifugal Pumps Designed for Thermal Growth Thermal Pipe Stress Analysis to Prevent Pipe Rupture & Increase Equipment Life Cellular Glass Insulation for Easy Leak Detection and Fire Prevention HTHO-100.0 Integrated Flow Solutions Heat Transfer/Hot Oil Systems are designed to store and transfer heat transfer fluids used for industrial heating. The heat transfer fluid is normally stored in an elevated insulated vessel skid mounted. Special high temperature centrifugal pumps are used to circulate the heat media fluid from the storage tank through an electric process heater, gas fired heater or exhaust heat exchanger. The heat transfer fluid’s elevated temperature is then used to safely heat a process system and is then returned to the storage vessel. Heat Transfer/ Hot Oil Systems Standard Features (Continued) Double Drop and By-Pass Expansion Tank for Venting of Low Boilers INTEGRAHEAT TM Electric Process Heaters Heat Transfer Oils - (15W/In2) To Reduce Coke Buildup and Maximize Oil and Heater Life Water - (45W/In2) To Minimize Scale Buildup and Maximize Heater Life TriEthylene Glycol - (12W/In2 - 15W/In2) To Minimize Degradation and Extend Heater Life On-Skid Across-the-Line Starting Control Panel Wired to Electric Motors Optional Features Metal Fiber Filters in 5-10% Slip Stream Flow to Prevent Fouling of System Ladder and Platform for Expansion Tank Access Air Cooler for Quick Shutdown API 610 Centrifugal, Canned Motor or Mag Drive Pumps PLC Control System with Data Highway IEC/CENELEC/CSA Compliant Control Panel, Conduit and Wiring Compliance with Plant/Engineering Specifications Additional Services Nationwide Service Network Installation/Training/Start-Up Supervision Equipment Leasing Program Extended Equipment Warranties “Aspen Plus” Process Simulation Software to Guarantee Process Conditions GENERAL POWER OIL & GAS www.IFSolutions.com INTEGRATED FLOW SOLUTIONS 9807 Whithorn Drive Houston, TX 77095 281-855-8125 / Toll-Free USA 800-795-4068 www.IFSolutions.com

Transcript of Heat Transfer / Hot Oil Systems - Integrated Flow Solutions · heater, gas fired heater or exhaust...

Page 1: Heat Transfer / Hot Oil Systems - Integrated Flow Solutions · heater, gas fired heater or exhaust heat exchanger. ... “Aspen Plus” Process Simulation Software to Guarantee Process

Industries

BenefitsSingle Source AccountabilityPre-Packaged Modular Design Costs Less Than Component Based Site-Built Systems Reducing Overall Project CostMinimizes Field Erection Time -Shorter Overall Project Delivery ScheduleComplete System Function TestingPrior To Shipment24/7 Customer Service

Industry StandardsVessels Code Stamped ASME Section VIII &National Board RegisteredPiping Designed to ANSI B31.1/ANSI B31.3Pipe Fabrication to ASME Section IXStructural Steel Assembly Designed to AWS D1.1

Standard FeaturesSpecial Centerline Mounted or Vertical InlineHigh Temperature Centrifugal Pumps Designedfor Thermal GrowthThermal Pipe Stress Analysis to Prevent PipeRupture & Increase Equipment LifeCellular Glass Insulation for Easy Leak Detectionand Fire Prevention

HTHO-100.0

Integrated Flow Solutions Heat Transfer/Hot Oil Systems aredesigned to store and transfer heat transfer fluids used forindustrial heating. The heat transfer fluid is normally stored inan elevated insulated vessel skid mounted. Special hightemperature centrifugal pumps are used to circulate the heatmedia fluid from the storage tank through an electric processheater, gas fired heater or exhaust heat exchanger. The heattransfer fluid’s elevated temperature is then used to safely heata process system and is then returned to the storage vessel.

Heat Transfer/Hot Oil Systems

Standard Features (Continued)Double Drop and By-Pass Expansion Tank for Venting of Low BoilersINTEGRAHEATTM Electric Process Heaters

Heat Transfer Oils - (15W/In2) To ReduceCoke Buildup and Maximize Oil andHeater LifeWater - (45W/In2) To Minimize Scale Buildupand Maximize Heater LifeTriEthylene Glycol - (12W/In2 - 15W/In2) To Minimize Degradation and ExtendHeater Life

On-Skid Across-the-Line Starting Control PanelWired to Electric Motors

Optional FeaturesMetal Fiber Filters in 5-10% Slip Stream Flowto Prevent Fouling of SystemLadder and Platform for Expansion Tank AccessAir Cooler for Quick ShutdownAPI 610 Centrifugal, Canned Motor or Mag Drive PumpsPLC Control System with Data HighwayIEC/CENELEC/CSA Compliant Control Panel,Conduit and WiringCompliance with Plant/Engineering Specifications

Additional ServicesNationwide Service NetworkInstallation/Training/Start-Up SupervisionEquipment Leasing ProgramExtended Equipment Warranties“Aspen Plus” Process Simulation Software toGuarantee Process Conditions

GENERALPOWER OIL & GAS

www.IFSolutions.com

INTEGRATED FLOW SOLUTIONS 9807 Whithorn Drive Houston, TX 77095 281-855-8125 / Toll-Free USA 800-795-4068

www.IFSolutions.com

Page 2: Heat Transfer / Hot Oil Systems - Integrated Flow Solutions · heater, gas fired heater or exhaust heat exchanger. ... “Aspen Plus” Process Simulation Software to Guarantee Process

Heat Transfer/Hot Oil Systems

INTEGRATED FLOW SOLUTIONS 9807 Whithorn Drive Houston, TX 77095 281-855-8125 / Toll-Free USA 800-795-4068LIT HTHO-100.0 03042004 IFS These materials contain proprietary information and may not be reproduced without prior written permission from Integrated Flow Solutions.

EXPANSION TANK DRY WEIGHTFLOW RATE (GPM) WORKING VOLUME (GALLONS) LENGTH - X WIDTH - Y HEIGHT - Z (LBS.)

50 500 6’ 4’ 12’ 2,000100 1,000 6’ 8’ 14’ 4,000200 2,000 8’ 10’ 16’ 8,000300 3,000 12’ 10’ 18’ 12,000500 5,000 20’ 10’ 20’ 20,000

P L A N V I E W E L E V A T I O N V I E W

"Y" O

VE

RA

LL S

KID

WID

TH

"X" OVERALL LENGTH

"H" O

VE

RA

LL S

KID

HE

IGH

T