1 Heat Transfer Equipments The transfer of heat to and from process fluid is an essential part of most chemical processes. The word exchanger really applies to all types of equipments in which heat is exchanged. There are many types of heat transfer equipment such: One of the simplest and cheapest types, it is a concentric pipe arrangement as shown below, it is only used for a small heat transfer area. 1-Double pipe exchangers: Fig. (1) Double pipe heat exchanger Hair pin exchangers are another types of double pipe heat exchangers, and it is formed by inserting one or more U-tubes into two pipe section welded to a large flanged, these exchangers are cheaper than shell and tube at very small sizes and can be specified for 7 to 170 m 2 area. It is consist of banks of finned tubes over which air is blown or drawn by fan mounted blown or above the tubes, it is a package unit. 2- Air Cooled Exchangers: Application: air cooled exchangers used if a- Water is expansive or there is shortage in cooling water. b- Process temperature above 65 0 c- Climate with high humidity, so air cooling will be cheaper than cooling tower. C.

Transcript of Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical...

Page 1: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

1

Heat Transfer Equipments The transfer of heat to and from process fluid is an essential part of most chemical processes. The word exchanger really applies to all types of equipments in which heat is exchanged.

There are many types of heat transfer equipment such:

One of the simplest and cheapest types, it is a concentric pipe arrangement as shown below, it is only used for a small heat transfer area.

1-Double pipe exchangers:

Fig. (1) Double pipe heat exchanger

Hair pin exchangers are another types of double pipe heat exchangers, and it is formed by inserting one or more U-tubes into two pipe section welded to a large flanged, these exchangers are cheaper than shell and tube at very small sizes and can be specified for 7 to 170 m2 area.

It is consist of banks of finned tubes over which air is blown or drawn by fan mounted blown or above the tubes, it is a package unit.

2- Air Cooled Exchangers:

Application: air cooled exchangers used if

a- Water is expansive or there is shortage in cooling water. b- Process temperature above 650

c- Climate with high humidity, so air cooling will be cheaper than cooling tower.

C.

Page 2: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

2

d- It is needs to avoid increasing the existing cooling tower load.

• The tubes used in air coolers are usually finned provide additional surface area.

Design Information:

• The ratio of finned tube to bare tube 20:1 • Standard tube length are used, the tube welded to a header at each end

of the exchanger. • The height of the tube bank above the ground must be at least half of

the tube length to give an inlet velocity equal to the face velocity. • The air temperature considerations (in design calculations) the highest

temperature that exceeded for 400 h/year. • The fan mounted into ways.

A-Above the tube racks (Induced draft) see fig.(2) :

1. A good air distribution across the tube racks. Advantages:

2. Less air recirculation. 3. The housing around the fan is similar to chimney effects.

1. The maintenance across is difficult. Disadvantages:

B-Below the tube racks (forced draft) see fig.(2) :

1. Easier access for maintenance. Advantage:

2. Reduce power requirements. 3. In winter air recirculation will may offset the effect of lower

ambient temperature. 4. Less expensive than induced draft.

Page 3: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

3

1. Air recirculation may happen during normal operation.

Disadvantages:

Fig. (2) Typical induced draft air-cooled exchanger showing two exchanger section and two fans.

In direct-contact heat exchangers the hot and cold streams are brought into contact without any separating wall.

3- Direct-Contact Heat Exchangers:

1. High rates of heat transfer are achieved. Advantages:

2. The equipment is simple and cheap. 3. It may use for heavily fouling fluids and liquid containing solids. 4. The size of the exchangers is not critical.

Page 4: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

4

Applications:

it is applied when the process stream and coolant are compatible cooling towers, reactor off-gas quenching.

Fig. (3) Typical direct-contact cooler (baffle plates)

Page 5: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

5

It is the most common type of heat transfer equipment used:

4- Shell and tube Exchangers:

1- The configuration gives a large surface area in small volume.

Advantages:

2- Good mechanical lay-out.

3- Well-established fabrication techniques.

4- Well-established design procedure.

5- Constructed from a wide range of materials.

6- Easily cleaned.

Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell –side and tube-side fluids. Baffles are provided in the shell to direct the fluid flow and support the tube.

Note: - temperature approach in shell and tube exchangers are between 5 -10 ºC.

Types of Shell and Tubes:

A- Fixed tube shell (TEMA type BEM) see Fig. (4)

1- Simple, cheap.

Advantages:

2- May be used for high pressure.

Page 6: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

6

1- Difficult to cleaning.

Disadvantages:

2- No provision of thermal expansion so the limiting temperature differences 80 0

C (between fluid in shell and tubes).

Fig. (4) Fixed tube shell

Page 7: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

7

B-U-tubes U bundle (TEMA type BEU) see Fig. (5)

Cheaper than floating head.

Advantages:

1- The fluid in tube must be relatively clean.

Disadvantages:

2- It is difficult to replace tubes.

Fig. (5) U-tubes U bundle

Page 8: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

8

C- Floating Head see Fig. (6)

1- Internal floating head (TEMA type AET and AES)

1- Very suitable for high temperature differential.

Advantages:

2-The tubes can be ridden from end to end and the bundle removed.

3- Can be used for fouling liquids.

1- The clearance between the tubes and the shell may allowing fluids to fluids to bypass the tubes.

Disadvantages:

2- External floating head (TEMA type AEP)

The same as internal floating head.

Advantages:

1-Is limiting for 20 bar pressure.

Disadvantages:

2- Flammable and toxic materials should not used in shell side.

Page 9: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

9

Fig. (6) Floating Head

Page 10: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

10

5- Plate Heat Exchangers:

Gasketed-Plate Heat Exchangers:

It is consists of a stack of closed spaced thin plates clamped together in a frame, a thin gasket seals the plates around their edge.

1- Low approach temperature can be used as 1

Advantages: 0

2- The exchangers more flexible easy to add extra plates. C.

3- Suitable for highly viscous materials. 4- The temperature correction factor higher than shell and tube.

1-The limitation of pressure not exceeds 30 bar.

Disadvantages:

2-The selection of suitable gasket is critical.

3-The maximum operating temperature is limited to about 250 0

4- Expansion than other types.

C.

5- The maximum flow rates of fluid 2500 m3/hr.

Page 11: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

11

Fig. (7) Casketed-plate heat exchanger

The plate surface area 0.3 – 1.5 m

Design Information:

The plate width /length ratio 2-3

2

The plate thickness 0.3 – 3mm

The gas between plates 1.5 – 3mm

Material of construction material and alloys

Page 12: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

12

They are directly heated by the products of combustions of a fuel

6 – Fired heaters furnaces and boilers:

They are constructed either rectangular or cylindrical steel chamber lined with refractory bricks

Tubes are arranged around the wall horizontally or vertically the fluid to be heated flows through the tubes.

UDesign Information

Tube diameter 75 -150 mm

Typical tube velocity's 1 -2 m/s

The fuel used: - natural gas, fuel oil, off-gases from the process

Excess air:- 20% for gaseous fuels

25% for liquid fuel

Fig. (8) Fired heater (a) Vertical-cylindrical, all radiant. (b) Vertical-cylindrical, helical coil. (c) Vertical-cylindrical with convection section.

Page 13: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

13

U7- Heat transfer to vessels:

A- UJacket vessels:-

The commonly used type is consists of an outer cylinder that surrounded part of the vessel.

The heating or cooling medium circulates in the annular space between the jacket and the vessel wall.

The space between the jacket and vessel wall typically a range from 50 to 300 mm

There are other types of jacket such as spirally baffled jacket, half pipe jacket.

UJacket selection factors:-

1-Cost 2- heat transfer rate required 3- Pressure

Fig. (9) Jacketed vessels. (a) Spirally baffled jacket. (b) Dimple jacket. (c) Half-pipe jacket. (d) Agitation nozzle.

Page 14: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

14

The prime objective in the design of an exchange is to determine the surface area required for the specified duty using the temperature differences available.

Design procedure:

The general equation for heat transfer across a surface is:-

𝑄𝑄 = 𝑈𝑈 𝐴𝐴 𝛥𝛥𝛥𝛥Rm

Where:-

Q = heat transferred per unit time, W.

U = the overall heat transfer coefficient W/m².ºC.

Δ TRmR = the mean temperature difference (driving force) ºC

The overall coefficient is the reciprocal of the overall resistance to heat transfer.

where UR0R = the overall coefficient based on the outside area of the tube, W/m2°C, hR0R = outside fluid film coefficient, W/m2°C, hRiR = inside fluid film coefficient, W/m2°C, hRodR = outside dirt coefficient (fouling factor), W/m2°C, hRidR = inside dirt coefficient, W/m2°C, kRwR = thermal conductivity of the tube wall material, W/m°C, dRiR = tube inside diameter, m, dR0R= tube outside diameter, m.

Page 15: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

15

Overall Heat Transfer Coefficient

Typical values for various types of heat exchangers can be found in the following.

1-TEMA Tubular heat Exchanger Manufactures Association

2-Ludwig ę 1965 “ Applied process Design for chemical and petrochemical plants” vol.3 by Gulf publishing company

3- Green .D.W and Perry .R.H 2007” Perry's Chemical Engineers hand book|” 8 edition McGraw-Hill

4-Sinnott R and Tower G 2009” Chemical Engineering Design” 5 th edition by Butterworth-Heinemann.

Fouling Factors (Dirt Factors)

Fluids (process and service) will foul, the deposited materials normally have allow thermal conductivity and thus normally reduce the overall coefficient.

Fouling factors are a heat transfer resistance and not as safety factor in exchanger design.

Mean temperature Differences

∆TRlm calculated from the differenc in the fluid temp.

At the inlet and outlet & the exchanger. (logarithmic mean)

The assumption used:-

• It is only applicable to sensible heat transfer in co- current or counter current flow.

• Linear temp – enthalpy curve.- • Heat capacities & both stream are constant.- • There is on phase change.- • There is no heat losses-

Page 16: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

16

For counter current

For shell and tube the flow will be a mixture of co- current counter-current and cross flow.

To estimate the true temperature difference FRtR have been, use which called the temperature correction factor.

FRtR =

shell and tube fluid temperatureno .tube and shell passes

R = shell side fluid flowrate ∗specific heattube side fluid flowrate ∗specific heat

= T1−T2t2−t1

S= t2−t1T1−t1

the temp. efficiency of the exchanger

Assumptions to calculate FRt

1- Equal heat transfer area.

2- A constant overall heat transfer coeff. in each pass .

3-The temp of the shell side in any pass is constant across section.

4-there is no leakage of fluid between shell passes.

FRt Rwill fall it there is a temp. cross where it is occur if the outlet temp. of cold stream is greater than the outlet temp. of the hot stream.

For economic reason FRtR must be not less than 0.75

Page 17: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

17

Shell and Tube Exchangers construction Details

Shell and tube consist of a bundle of tubes. enclosed in a cylindrical shell , the ends of the tubes are fitted into tube sheets which separate the shell side and tube side fluids .

Tubes in Exchangers

Tube used ¼ -2 in recommended 5/8 -1 in

Because they give a more compact exchangers larger diam. May use to heavily fouling fluids

Tube Thickness

Depends on internal and external pressure and corrosion allowance.

Tube length

Actually it is need to know the tube length available in local market.

Notes:- Using longer tubes will reduce shell diameter lower cost and better heat transfer rate, but pressure drop will be high

Tube Arrangement

1- Equilateral triangular. Pattern

2-Squrare Pattern

3-Rotated Square .Pattern

The recommended tube pitches 1.25 times the tube outside diam.

Tube Side passes

To increase tube side design velocity the tube arranged in parallel and directed the fluid in the tube to flow back(𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝) usually, To 16 passes

Page 18: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

18

The recommended velocities in tubes are:-

For liquids, 1 to 2 m/s, max 4 m/s

Vapor at atmosphere pressure 10-30 m/s

High pressure 5-10 m/s

Vacuum 50 -70 m/s

Shell side 0.3 to 1 m/s

Shells

Shell diameter from 10 in t0 6o inch it is preferred to use pipe if available.

Shell Thickness

Shell are considers as pressure vessels so the thickness may estimate by :-

T= 𝑃𝑃𝑃𝑃 𝐷𝐷𝑃𝑃2𝑝𝑝𝛿−1.2𝑝𝑝𝑃𝑃

+ c

Where:-

T= the minimum thickness required, mm

Pi= Internal pressure, N/ mmP

2

Di=Internal Diam., mm

S= maximum allowable stress, N/ mmP

2

𝛿 = Welded joint efficiency.

C=corrosion allowances.

Estimation & heat transfer Coefficient Inside tubes hRi

ℎ𝑃𝑃 𝑑𝑑𝑃𝑃𝑘𝑘𝑘𝑘 = 𝑗𝑗ℎ 𝑅𝑅𝑝𝑝 𝑝𝑝𝑝𝑝^0.33 �

µµ𝑤𝑤�

Where jh can be obtained from figures

Page 19: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

19

Viscosity Correction Factor

It used only for viscous liquids

1-calculate the coefficient without correction 2-hi (tw-t) = U(T-t) Where:- t=tube side bulk temp mean. T=shell side bulk temp mean. tw=estimated wall temp. 3- Made a trial and error to get the actual tw.

Estimation of Heat Transfer Coeff. in shell side ho

𝐷𝐷𝑝𝑝 = 1.1

𝑑𝑑𝑜𝑜 (𝑝𝑝𝑘𝑘2 − 0.917 𝑑𝑑𝑜𝑜2 )

Gs= Re =

As=

Where:-

PRtR=tube pitch.

dRoR=tube outside diam.

DRsR=shell inside diam.

Page 20: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

20

Pressure Drop Calculation in tube Side

There are two sources for pressure drop

1- friction loss in the tubes.

2- loss due to sudden contraction and expansion flow reversal in the headers.

The optimum P

Allowable press. drop viscosity

For liquid

<1 mNs/mP

2 P35 kN/mP

2 P P

1to 10 mNs/mP

2 P50-70 kN/mP

2 P

For gases or Vapors.

High vac. 0.4-0.8 kN/mP

2

Medium vac. 0.1*absolute press.

1-2 Bar 0.5*system gauge pressure

above 10 bar 0.1*system gauge pressure

pRt R=Np

m=for laminar flow R

for turbulent flow Re 2100 =0.14

Np=No.& tube side passes

URtR=tube side velocity .m/s

Pressure Drop. Calculation in shell side

Ps= 8jf

Page 21: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

21

CONDENSERS

This section covers the design of shell and tube exchangers used as

condensers.

The construction of a condenser will be similar to other shell and tube

exchangers, but with a wider baffle spacing, typically IB = D

Four condenser configurations are possible:

1. Horizontal, with condensation in the shell, and the cooling medium in the

tubes.

2. Horizontal, with condensation in the tubes.

3. Vertical, with condensation in the shell.

4. Vertical, with condensation in the tubes.

Horizontal shell-side and vertical tube-side are the most commonly used

types of condenser. A horizontal exchanger with condensation in the tubes is

rarely used as a process condenser, but is the usual arrangement for heaters

and vaporisers using condensing steam as the heating medium.

The normal mechanism for heat transfer in commercial condensers is film

wise condensation. Using Kern's method, the mean coefficient for a tube bundle is given by:

Page 22: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

22

and L = tube length,

Wc

N

= total condensate flow,

t

N

= total number of tubes in the bundle,

r

N

= average number of tubes in a vertical tube row.

r

can be taken as two-thirds of the number in the central tube row.

(ℎ𝑐𝑐) 𝑝𝑝 = 0.76𝑘𝑘𝐿𝐿 � 𝜌𝜌𝐿𝐿 (𝜌𝜌𝐿𝐿−𝜌𝜌𝑣𝑣 ) 𝑔𝑔

𝜇𝜇𝐿𝐿 𝛤𝛤ℎ � 1/3

Steam is frequently used as a heating medium. The film coefficient for

condensing steam can be calculated using the methods given in the previous

sections; it is customary to assume a typical, conservative, value for design

purposes. For air-free steam a coefficient of 8000 W/m2°C (1500 Btu/h

ft2

A pure, saturated, vapour will condense at a fixed temperature, at constant

pressure. For an isothermal process such as this, the simple logarithmic

mean temperature difference can be used in the equation 12.1; no correction

factor for multiple passes is needed. The logarithmic mean temperature

difference will be given by:

°F) can be used.

where Tsat

t

= saturation temperature of the vapor,

1 = inlet coolant temperature,

Page 23: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

23

t2

Reboilers and vaporizers

= outlet coolant.

Three principal types of reboiler are used: 1. Forced circulation, Fig. 10: in which the fluid is pumped through the

exchanger, and the vapour formed is separated in the base of the

column. When used as a vaporiser a disengagement vessel will have

to be provided.

Fig. (10) forced-circulation reboiler

2. Thermosyphon, natural circulation, Fig. 11: vertical exchangers with

vaporization in the tubes, or horizontal exchangers with vaporisation

in the shell. The liquid circulation through the exchanger is

maintained by the difference in density between the two-phase

mixture of vapour and liquid in the exchanger and the single-phase

liquid in the base of the column. As with the forced-circulation type, a

disengagement vessel will be needed if this type is used as a

vaporiser.

3. Kettle type, Fig. 12: in which boiling takes place on tubes immersed

in a pool of liquid; there is no circulation of liquid through the

Page 24: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

24

exchanger. This type is also, more correctly, called a submerged

bundle reboiler.

Choice of type

The choice of the best type of reboiler or vaporiser for a given duty will

depend on the following factors:

1. The nature of the process fluid, particularly its viscosity and propensity to

fouling,

2. The operating pressure: vacuum or pressure.

3. The equipment layout, particularly the headroom available.

Forced-circulation reboilers are especially suitable for handling viscous and

heavily fouling process fluids. The major disadvantage of this type is that a

pump is required and the pumping cost will be high.

Fig. (11) horizontal thermosyphon reboiler

Page 25: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

25

Fig. (12) kettle reboiler

Fig. (13) internal reboiler

Thermosyphon reboilers are the most economical type for most applications,

but are not suitable for high viscosity fluids or high vacuum operation. A

Page 26: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

26

disadvantage of this type is that the column base must be elevated to provide

the hydrostatic head required for the therrnosyphon effect.

Kettle reboilers have lower heat-transfer coefficients than the other types, as

there is no liquid circulation. They are not suitable for fouling materials, and

have a high residence time. They will generally be more expensive than an

equivalent therrnosyphon type as a larger shell is needed, but if the duty is

such that the bundle can be installed in the column base, the cost will be

competitive with the other types.

Design of kettle reboilers

1. The tube arrangement, triangular or square pitch, will not have a

significant effect on the heat-transfer coefficient.

2. A tube pitch of between 1.5 to 2.0 times the tube outside diameter

should be used to avoid vapour blanketing. Long thin bundles will be

more efficient than short fat bundles.

3. The shell should be sized to give adequate space for the

disengagement of the vapour and liquid. The shell diameter required

will depend on the heat flux.

can be used as a guide:

Heat flux W/m Shell dia./Bundle dia. 2 25,000 1.2 to 1.5 25,000 to 40,000 1.4 to 1.8 40,000 1.7 to 2.0

The freeboard between the liquid level and shell should be at least 0.25 m.

Page 27: Heat Transfer Equipments · Shell and tube consists of a bundle of tubes enclosed in a cylindrical shell. The ends of the tubes are fitted into tube shell, which separate the shell

27

Mean temperature differences When the fluid being vaporised is a single component and the heating

medium is steam (or another condensing vapour), both shell and tubes side

processes will be isothermal and the mean temperature difference will be

simply the difference between the saturation temperatures. If one side is not

isothermal the logarithmic mean temperature difference should be used. If

the temperature varies on both sides, the logarithmic temperature difference

must be corrected for departures from true cross- or counter-current flow.