Headend Power - KABELKON · > Headend Power ToTal Power ... Argus Technologies, ... Tempest Te20b...

104
> Headend Power TOTAL POWER SOLUTIONS BY ALPHA TECHNOLOGIES

Transcript of Headend Power - KABELKON · > Headend Power ToTal Power ... Argus Technologies, ... Tempest Te20b...

> Headend PowerToTal Power SoluTionS by alPHa TecHnologieS

2

Alpha Technologies> Company Overview

Alpha Technologies pioneered the concept of reliable standby power for the cable television industry,

and in the process has set a 30-year precedent for visionary, market-driven power solutions. Today,

Alpha continues to focus on providing the communications industry with the most reliable, innovative

and cost-effective powering solutions available. Hundreds of dedicated Alpha engineers, technicians,

craftspeople and field specialists share this focus. These are inspired people creating proactive

solutions that help shape the future of the industry and Alpha itself - a company where people and

power come together.

> The Alpha GroupThe Alpha Group represents an alliance of independent companies sharing a common philosophy - to

create world-class powering solutions. Collectively, Alpha Group members develop and manufacture

AC and DC power conversion, protection and standby products. Applications for these products

include broadband, telecom, AC/UPS, commercial, industrial and renewable energy for a worldwide

customer base. In addition, our companies provide a range of installation and maintenance services.

Members of The Alpha Group include Alpha Technologies, Alpha Energy, Alpha Industrial Power, Argus

Technologies, Alpha Technologies Services and G.B. Enterprises.

3

Table o

f Co

nten

ts

Table of Contents> DC Power Systems 5-25

Matrix of Cordex™ DC Power Systems ..................6

Cordex Controller Features ...................................7

Cordex Comparison Chart ....................................8

Cordex CXCR/CXCP .............................................9

Cordex CXCM4 ...................................................10

Cordex CXCM2 ...................................................10

Cordex CXCM ..................................................... 11

Cordex CXCI ........................................................ 11

Cordex 400 and 650W ........................................ 12

Cordex 1kW ......................................................... 14

Cordex 1.8kW ......................................................16

Cordex 3.6kW ..................................................... 17

Cordex System .................................................... 18

CXPS 48-1T .........................................................20

CXPS 48-2T .........................................................21

CSM01 and CSM02 ............................................22

Distribution Centers .............................................23

DC Accessories ...................................................24

> Headend batteries 27-31

Headend Batteries ..............................................28

AlphaGuard™ .......................................................30

Battery Testing Equipment ..................................31

> Dc to ac inverters 33-41

SMI 3300 Inverter Series .....................................34

Tebevert Inverter Series .......................................35

INEX Inverter System ...........................................36

S4 Inverter Series ................................................38

DSP Inverter Series .............................................39

S5 Inverter Series ................................................40

MS Power Inverter Series .................................... 41

> netbotz® Monitoring 43

> Single and Three Phase uPS 45-63

SmartUPS® XL.....................................................46

SmartUPS RT ......................................................48

Symmetra® ..........................................................52

Symmetra LX .......................................................53

1600EP Series .....................................................56

Triniti™ 4200 Series ..............................................57

Galaxy..................................................................58

Galaxy 4000 ........................................................59

Symmetra PX .......................................................60

Galaxy PW Series ................................................62

EPS 7000.............................................................63

> alphaTVSS™ Surge Suppression 65

> alpha Technologies Services 67

> FTTx Power 69-77

FlexPoint™ 1230 Series ........................................70

FlexPoint AX Series .............................................71

FlexNet™ FMPS .................................................... 74

FlexNet FiberUPS ................................................75

PMR and GMR Series .........................................76

Radium MiniBay™ ................................................77

> alpha enclosures 79-85

Tempest Te25 / Te25xh .......................................80

Tempest Te15 ......................................................81

Tempest Te17 ......................................................82

Tempest Te20 ......................................................83

Tempest Te20b ....................................................84

Tempest Te21 ......................................................85

> racks and rack accessories 87-93

SX 42RU Rack .....................................................88

SX 48RU Rack .....................................................89

4 Post Open Frame Racks ..................................90

In Row Rack Cooling ...........................................91

Rack Air Distribution Unit .....................................92

Rack Air Removal Unit .........................................92

Rack Hardware and Accessories ........................93

> alphagen™ generators 95-97

AlphaGen 3.5kW to 2MW Systems .....................96

AlphaGen Telecom ..............................................97

> alpha building Systems 99

> notes 100

4

Table o

f Co

nten

ts

5

DC

Po

wer S

ystems

DC Power SystemsThe Alpha Group has more than 30 years of experience providing a wide variety of fully integrated

power system solutions. With options for standardized systems and custom DC system integration,

The Alpha Group has the flexibility to provide DC power solutions perfect for a wide range of power

needs and various site installation requirements.

Integrated shelf systems are available for all small power rectifier models providing a complete power

solution in a single rackmount package. These systems incorporate a Cordex™ controller, rectifiers and

DC distribution options in a compact shelf design. Optional accessories such as LVDs, shunts and

temperature compensation are available.

For medium to large system applications, The Alpha Group can provide both standard and custom DC

system solutions designed to maximize space and cost savings. Systems can be integrated with a

wide array of options including various rack solutions, custom DC distribution configurations, multiple

voltage output designs and front access.

Coupling advanced Cordex power technology with an enormous selection of system components,

The Alpha Group can easily provide optimal system solutions up to 8,000 Amps.

6

DC

Po

wer

Sys

tem

s

48-3.6kwMulti bay

48-3.6kwSingle bay

48-1.8kwSingle shelfwith expansion

48-1kwSingle shelf

48-650wSingle shelfwith expansion

24-400wSingle shelfwith expansion

20a

AMPS (not to scale)

14a

140a

75a

2000a

13a

65a

130a

37a

187a

Dc Power Systems 48V 24V

CXCM4 CXCP

CXCICXCM2CXCR

CXCMCXCR

CXCI

CXCI

500a

8000a

CXCR

6000a

4000a

2000a

450a

900a

1350a

8000

6000

4000

2000

1000

800

600

400

200

175

150

125

100

75

50

25

0

120a

70a

375a

Matrix of Dc Power Systems

7

DC

Co

ntro

llers

cordex™ controller Features

> Main• WebbasedGUIInterface:Webbrowsersupportforlocalor

remote control and monitoring

• Singlepointsetupandcontrol

• Autovoltageadjustmentandloadsharing

• Analogdigitalinputs

• ConfigurableFormCrelayoutputs

• Variouspresetalarmsandabilitytoconfigureupto

20 customized alarms

• Userprogrammablelogicstatements

• LegacyPowerSystemUpgrade:ControlslegacyPathfinder

based systems and can be used as a site monitor for any 3rd

party DC power system

• CANCommunications:Commonplatformforpowerelectronics

and peripherals, rugged and field proven protocol

• FailSafeSystemOperation:IntheeventofCXCfailure,

rectifiers continue to run with default settings, fail alarm is

generated and LVDs (if equipped) remain energized

• PowerSaveFunction:Improvesoperationalefficiencyby

running the minimum number of rectifier modules required

per system load

• SystemStartDelay:AllowsdelayforotherACpowered

equipment to start before rectifiers

• RampTestControl:Disablesfailalarmonno-loadconditions.

• SNMPSupport:Networkmanagementservicesupportfor

managing multiple systems in a single network

• EmailnotificationsviaTCP/IP

• CordexPeripheralSupport:Optionaladd-onsforindividualcell

and temperature monitoring and controller I/O expansion

• MultilanguagesupportincludingChinesecharacters

> Battery Management• TemperatureCompensatedFloatVoltage:Increasesvoltagein

temperatures below 25˚C / 77˚F and decreases charge voltage

above 25˚C / 77˚F. Maximizes life and capacity of battery and

prevents thermal runaway

• BatteryEqualize:Manual,automaticandperiodicequalize

charge modes, optional Battery Current Terminate function to

prevent over charging of battery

• BatteryBoostMode:Offlinehigh-voltageequalizechargewith

interlock safety feature

• DynamicChargeCurrentControl:Limitsbatteryrecharge

current to a fixed value, helps prevent thermal runaway

• BatteryTest:Setsrectifiervoltagelowandperformssafe

discharge of batteries through the connected system loads

• BatteryCapacityPrediction:Calculatescurrentbattery

capacity after a discharge

• BatteryRuntimePrediction:Basedoncurrentbatterycapacity

and system load

• BatteryLogging:Retainupto40recordsofbattery

statistics and events

> Maintenance• DataLogger:Recordanysysteminput(s),andsetsamplerate

of record on deviation, store up to 500 events via manual or

auto start/stop

• Typicaldatalogapplications:Detailedbattery

discharge information, AC voltage watch dog and outdoor

cabinet thermal performance

• EasyRemoteSoftwareUpgrades:Fail-safeprotected

upgrades for controllers, rectifiers and peripherals

> The Cordex CXC is the latest generation of advanced digital controllers for DC power system monitoring and control. Cordex supervisory controllers come in a wide array of modular designs for compact integration into Alpha Group DC systems. Standalone rackmount versions are also available for DC systems, legacy controller upgrades and site monitoring. A graphic LCD display with state-of-the-art touch-screen interface allows simple and convenient set up, control and monitoring. Innovative IP technology allows complete configuration and monitoring from any location via the Internet using a standard web browser.

8

DC

Co

ntr

olle

rs

cordex controller Series

CXCR/CXCP CXCM4 CXCM2 CXCM CXCI

Specifications

Screen:Full Graphic LCD 160 x 160 pixels

Full Graphic LCD 160 x 160 pixels

Full Graphic LCD 160 x 160 pixels

Full Graphic LCD 160 x 160 pixels

Basic Current / Volts Display Only

Inputs

analog: 2V, 2T, 4C, 2BIV 2V, 2T, 4C, 2BIV 1V, 2T, 2C, 4BIV 2V, 2T, 1C, 1BIV 1V, 1C, 2T

Digital: 8 4 6 3 2

alarm relay outputs: 8 Form C 8 Form C 6 Form C 8 Form C 4 Form C

Dimensions

Height x width x Depth (in/mm):

5.1 x 16.9 x 3.9 / 131 x 431 x 100

7 x 3.4 x 10.1 / 177 x 87 x 257

3.4 x 5 x 9.7 / 86.4 x 128 x 247

6.9 x 2.9 x 10 / 177 x 74 x 255

3.5 x 1 x 11 / 88 x 26 x 280

Rectifier Shelf Option Availability

3.6kw (48Vdc): Yes Yes

1.8kw (48Vdc): Yes Yes Yes

1kw (48Vdc): Yes Yes

650w (48Vdc): Yes

400w (24Vdc): Yes

cordex™ comparison chart

> Cordex Controllers come standard with several advanced battery management features to allow for significant savings of capital and operational expenses. Some additional features include user definable alarms with custom algorithms, digital and analog input monitoring, data logging, integrated SNMP and CAN bus communications. The Cordex CXC is designed for effortless operation of the Cordex rectifier family, making time consuming and complicated set up and monitoring of DC power systems a thing of the past.

9

DC

Co

ntro

llers

cordex cXcr/cXcP

Features

Display:LCD Touchscreen Display (160 x 160 Pixels), “OK/Major/Minor”3-Color,LEDDisplay,WebBased GUI Via Ethernet

communication Ports:RJ45 Ethernet Port (Front Accessible Rear Port), RS232 Craft Port (Front), RS232 Modem Port (Optional)

Controller I/O

Voltage inputs: 2

Temperature inputs: 2

current inputs: 4

bi Voltage inputs: 2

Digital inputs: 8

relay outputs: 8

Electrical

input Voltage: 17 to 65Vdc

current: <100mA @ 48Vdc or < 200mA @ 24Vdc

Mechanical

Dimensions (Plus 19" or 23" Mounting bracket) (in/mm):

5.1 x 16.9 x 3.9 / 131 x 431 x 100

Mounting:CXCR with 19" or 23" rackmounting CXCP panel mount

weight (lb/kg): 13.8 / 6.2

cordex™ cXcr/cXcPSystem Controller

> LCD touch-screen user interface

> Internet ready, integrated SNMP

> High reliability CAN bus communication

> User definable alarms

> Flexible battery management features

> Smart peripheral monitoring features

> 19" and 23" Universal rack or panel mount configurations

CXCR Rackmount Controller

Environmental

extended Temperature: -40 to 65°C / -40 to 149°F

Humidity: 0 to 95% non-condensing

Standards

Safety:

CSA C22.2 No 60950-1-03 UL 60950-1 1st Edition CE marked IEC/EN 60950-1

eMc: ETSI 300 386

emissions:

CFR47 (FCC) Part 15 Class B ICES-03 Class B EN55022 (CISPR 22) Class B C-tick (Australia)

immunity:

EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6

10

DC

Co

ntr

olle

rs

cordex cXcM2

Features

Display:LCD Touchscreen Display (160x160 pixels), “OK / Major/Minor”3-Color,LEDDisplay,WebBasedGUI Via Ethernet

communication Ports: RJ45 Ethernet Port (Front)

Controller I/O

Voltage inputs: 1 + 1 Internal

Temperature inputs: 2

current inputs: 2

Digital inputs: 6

relay outputs: 6

Electrical

input Voltage: 17 to 65Vdc

current: <100mA @ 48Vdc or <200mA @ 24Vdc

Mechanical

Dimensions (in/mm): 3.4 x 5 x 9.7 / 96.4 x 128 x 247

Mounting: Modular controller for 1.8kW shelves

Environmental

extended Temperature: -40 to 65°C / -40 to 149°F

Humidity: 0 to 95% non-condensing

Standards

Safety:CSA C22.2 No 60950-1-03 UL 60950-1 1st Edition CE marked

cordex cXcM2System Controller

> LCD touch-screen user interface

> Internet ready, integrated SNMP

> High reliability CAN bus communication

> 2RU modular CXC for 1.8kW rectifiers

CXCM2

cordex™ cXcM4System Controller

> User definable alarms and data logging

> Flexible battery management features

> Smart peripheral monitoring features

> 4RU modular CXC for 3.1/3.6kW rectifiers

cordex cXcM4

Features

Display:LCD Touchscreen Display (160x160 pixels), “OK / Major/Minor”3-Color,LEDDisplay,WebBasedGUI Via Ethernet

communication Ports: RJ45 Ethernet Port, RS232 Craft Port (Front)

Controller I/O

Voltage inputs: 1 + 1 Internal

Temperature inputs: 2

current inputs: 4

bi Voltage inputs: 2

Digital inputs: 4

relay outputs: 8

Mechanical

Dimensions (in/mm): 7.0 x 3.4 x 10.1 / 177 x 87 x 257

weight (lb/kg): 3.9 / 1.8

Mounting: Modular controller for 3.1kW and 3.6kW shelves

Environmental

extended Temperature: -40 to 65°C (-40 to 149°F)

Humidity: 0 to 95% non-condensing

Standards

Safety:

CSA C22.2 No 60950-1-03 UL 60950-1 1st Edition CE marked IEC/EN 60950-1

eMc: ETSI 300 386

emissions:

CFR47 (FCC) Part 15 Class B ICES-03 Class B EN55022 (CISPR 22) Class B C-tick (Australia)

immunity:

EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6

CXCM4

11

DC

Co

ntro

llers

cordex™ cXcMSystem Controller

> LCD touch-screen user interface

> Internet ready, integrated SNMP

> High reliability CAN bus communication

> User definable alarms and data logging

> 4RU modular CXC for 1kW rectifiers

cordex cXci

Features

integrated option on 1.8kw, 650w, 400w, and 250w shelves

Display:4LCDforV/IDisplay,“OK/Major/Minor”3-Color, LED Display, Web Based GUI Via Ethernet

communication Ports:RJ45 Ethernet Port (Front), RS232 Modem Port (Front)

Controller I/O

Voltage inputs: 1 + 1 Internal

Temperature inputs: 2

current inputs: 1

Digital inputs: 4

relay outputs: 4

Electrical

input Voltage: 17 to 65Vdc

current: <100mA @ 48Vdc or < 200mA @ 24Vdc

Mechanical

Dimensions (in/mm): 3.5 x 1 x 11 / 88 x 26 x 280

Mounting: Integrated on Cordex 2RU series 19" and 23" shelves

Environmental

Temperature: -40 to 65°C / -40 to 149°F

Humidity: 0 to 95% non-condensing

Standards

Safety:CSA C22.2 No 60950-1-03UL 60950-1 1st EditionCE marked

> Control and monitor via Internet Explorer browser

> Flexible battery management features

> Smart peripheral monitoring features

> Integrated controller for 2RU rectifiers

cordex cXciSystem Controller

CXCI

cordex cXcM

Features

Display:LCD Touchscreen Display (160 x 160 Pixels), “OK/Major/Minor”3-Color,LEDDisplay, Web Based GUI Via Ethernet

communication Ports:RJ45 Ethernet Port (Front Accessible Rear Port) RS232 Craft Port (Front) RS232 Modem Port (Optional)

Controller I/O

Voltage inputs: 1 + 1 Internal

Temperature inputs: 2

current inputs: 1

bi Voltage inputs: 1

Digital inputs: 3

relay outputs: 8

Mechanical

Dimensions (in/mm): 6.9 x 2.9 x 10 / 177 x 74 x 255

weight (lb/kg): 3.9 / 1.8

Mounting: Modular controller for 1kW rectifier

Environmental

extended Temperature: -40 to 65°C / -40 to 149°F

Humidity: 0 to 95% non-condensing

Standards

Safety:

CSA C22.2 No 60950-1-03 UL 60950-1 1st Edition CE marked IEC/EN 60950-1

eMc: ETSI 300 386

emissions:

CFR47 (FCC) Part 15 Class B ICES-03 Class B EN55022 (CISPR 22) Class B C-tick (Australia)

immunity:

EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6

CXCM

12

DC

Rec

tifi

ers

cordex™ 400 and 650wModular Switched Mode Rectifier

Mechanical

Dimensions (in/mm): 3.4 x 2.8 x 9.5 / 88.4 x 71.6 x 242

weight (lb/kg): 3 / 1.4

Features

indicators:AC mains OK — green LED Module alarm — red LED

cooling: Natural convection

adjustments(via cXci controller):

Float and equalize voltageBattery test voltage High and low voltage alarms High voltage shutdown Current limit Start delay time Slope %

Protection:

Current limit/short circuit Input/output fuses Output high voltage shutdown Output power limiting Thermal foldback/shutdown Input transient AC low line foldback/shutdown AC high voltage shutdown

Environmental

operation Temperature: -40 to 50°C / -40 to 122°F (power derated up to 70°C / 158°F)

Storage Temperature: -40 to 85°C / -40 to 185°F

Humidity: 0 to 95% non-condensing

elevation: -500 to 3000m / -1640 to 9840ft

Heat Dissipation: <94BTU per hour

Standards

Safety:

CSA C22.2 No 60950-1-03 UL 60950-1 1st Edition CE marked IEC/EN 60950-1

eMc: ETSI 300 386

emissions:

CFR47 (FCC) Part 15 Class BICES-03 Class BEN55022 (CISPR 22) Class BC-tick (Australia)EN 61000-3-2EN 61000-3-3

immunity:

EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-11 ANSI/IEEE C62.41 Cat B3

CXRC 24-400W

> Available in 13.5A @ 48Vdc and 14A @ 24Vdc

> High power density

> Power limiting and wide range AC input

> 91% efficiency and power factor correction

> Hot swappable, 2RU ultra compact design

cordex 400w rectifier Module

Electrical

input Voltage: 90 to 320Vac

Power output: 400W

input Frequency: 45 to 70Hz

Power Factor: >99%

THD: <5%

efficiency: >90%

output Voltage: 20 to 29Vdc

output current: 14A @ 27Vdc (14A max)

load regulation:Static <±0.5%, Dynamic <±2% for 50 to 100%

load step, 2ms recovery time

line regulation:Static <±0.1%. Dynamic <±1% for any change

within rated limitsNoise

wide band noise: <30mVrms, <150mVp-p

Psophometric noise: <1mV

cordex 650w rectifier ModuleElectrical

Input Voltage (120Vac model)

operating: 90 to 140Vac (output power 650W)

extended: 90 to 70Vac (derated output power)

Power output: 650W at nominal 120Vac

Input Voltage (Universal 100 to 240Vac model)

operating: 176 to 320Vac (output power 650W)

extended: 176 to 90Vac (derated output power)

operating: 100 to 140Vac (output power 500W)

Power output: 650W at nominal 208 to 240Vac and 500W at nominal 120Vac

Nominal Specifications

input Frequency: 45 to 70Hz

Power Factor: >99%

THD: <5%

efficiency: >91% (1% loss for 120Vac model)

output Voltage: 42 to 58Vdc

output current: 12A @ 54Vdc (13.5A max)

load regulation:Static <±0.5%, Dynamic <±2% for 50 to 100%

load step, 2ms recovery time

line regulation:Static <±0.1%. Dynamic <±1% for any change

within rated limits

Noise

wide band noise: <30mVrms, <150mVp-p

Psophometric noise: <1mV

13

DC

Rec

tifiers

cordex 24-400w rectifier ShelvesRectifiers Controllers Distribution

19" 2RU Flush Mount

4 x CXRC 24-400W

1 x CXCI(4) AM Bullet type breakers

19" 2RU Flush Mount

5 x CXRC 24-400W

1 x CXCI

Bulk power for external distribution panel

19" and 23" Shelf Systems

650W Cordex 2.6kW shelf power system with CXCI controller and bullet breaker distribution

650W Cordex 3.2kW bulk power system with CXCI controller. Optional LVD shunt with battery breaker

650W Cordex 2.6kW front access shelf power system with CXCI controller and breaker/fuse distribution

400W Cordex 1.6kW shelf power system with CXCI controller and bullet breaker distribution

400W Cordex 2kW bulk power system with CXCI controller

cordex 48-650w rectifier ShelvesRectifiers Controllers Distribution

19" 2RU Flush Mount

4 x CXRC 48-650W

1 x CXCI(4) AM bullet type breakers

19" 2RU Flush Mount

5 x CXRC 48-650W

1 x CXCI

Bulk power for external distribution panel

23" 2RU Center Mount Front Access

4 x CXRC 48-650W

1 x CXCI(4) AM bullet(10) GMT fuse

19" Shelf SystemsMechanical

Dimensions (in/mm): 3.5 x 17.1 x 11.9 / 89 x 435 x 302

weight (lb/kg): 15.5 / 6.9

Note:Weights DO NOT include modules. Dimensions DO NOT include mounting bracket.

23" Shelf Systems

Mechanical

Dimensions (in/mm): 3.5 x 21.4 x 12 / 89 x 544 x 307

Mounting: Center mount; 1.75" and 1" racks

weight (lb/kg): 37 / 16.8 (Fully equipped with four rectifiers)

Note:Weights DO NOT include modules. Dimensions DO NOT include mounting bracket.

Communication Ports

can: Interface to control rectifiers. Smart peripherals.

ethernet: 10/100 Base-T for TCIP/SNMP features.

Environmental

operating Temperature: -40 to 50°C / -40 to 122°F

Storage Temperature: -40 to 85°C / -40 to 185°F

Humidity: 0 to 95% non-condensing

elevation: -500 to 3000m / -1640 to 9840ft

cooling: Natural or forced convection, vertical airflow

cordex™ 400w/650wRectifier Shelf Systems

> Integrated DC distribution with optional LVD

> Integrated 24 and 48Vdc shelf power systems up to 2.6kW

> Bulk 24 and 48Vdc power systems up to 3.2kW

> 19" and 23" rackmounting solutions

> Designed for CSA, UL, CE, FCC and C-tick standards

Cordex 48V-2.6kW Shelf System

Cordex 24V-1.6kW Shelf System

14

DC

Rec

tifi

ers

cordex™ 1kwModular Switched Mode Rectifier

cordex 1kw

Electrical

nominal input Voltage: 208 to 277Vac

operating input Voltage: 150 to 320Vac

extended input Voltage: 150 to 90Vac (derated power)

input Frequency: 45 to 66Hz

Power output: 1000W continuous/module

Power Factor: >0.99

efficiency: >92%

output Voltage: 42 to 60Vdc

output current: 18.5A @ 54Vdc (20.8A maximum)

load regulation: <±0.5% (static)

line regulation: <±0.1% (static)

Transient response: ±1% for 50 to 100% load step, 2ms recovery time

Noise

Voice band: <32dBrnC

wide band: <5mVrms, <100mVp-p

Psophometric: <1mV

Mechanical

Dimensions (in/mm): 6.9 x 2.8 x 9.8 / 177 x 71 x 250

weight (lb/kg): 6.4 / 2.9

Features

indicators:AC mains OK — green LED Module OK — green LED Module alarm — red LED

cooling: Natural convection

adjustments (via cXc controller):

Float and equalize voltage Battery test voltage High and low voltage alarms High voltage shutdown Current limit Start delay timers Slope %

Protection:

Current limit/short circuit Start delay Input/output fuses Output high voltage shutdown Output power limiting Thermal foldback/shutdown Input transient AC low line foldback/shutdown AC high voltage shutdown

Environmental

operation Temperature: -40 to 50°C / -40 to 122°F (with short periods up to 70°C / 158°F)

Storage Temperature: -40 to 85°C / -40 to 185°F

Humidity: 0 to 95% non-condensing

elevation: -500 to 4000m / -1640 to 13120ft

Heat Dissipation: <295BTU per hour

Standards

Safety:

CSA C22.2 No 60950-1-03 UL 60950-1 1st Edition CE marked IEC/EN 60950-1

eMc: ETSI 300 386

emissions:

CFR47 (FCC) Part 15 Class B ICES-03 Class B EN55022 (CISPR 22) Class B C-tick (Australia) EN 61000-3-2 EN 61000-3-3

immunity:

EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-11 ANSI/IEEE C62.41 Cat B3

> Available in 20.8A @ 48Vdc

> Power limiting and wide range AC input

> 92% efficiency and power factor correction

> Convection cooled

> Hot swappable, 4RU ultra compact design

CXRC 48-1kW

15

DC

Rec

tifiers

cordex™ 1kwModular Rectifier Shelf Systems

> Integrated 48Vdc shelf power systems up to 4kW

> Bulk 48Vdc power systems up to 6kW

> Distribution modules available for DIN or bullet type breakers

> 19" and 23" rackmounting solutions

> Designed for CSA, UL, CE and C-tick standards

cordex 1kw rectifier Shelves

Rectifiers Controllers Distribution

19" Flush Mount 5 x CXRC 48-1kW CXCM Bulk power for external distribution panel

19" Flush Mount 6 x CXRC 48-1kW Requires CXCR rackmount controller Bulk power for external distribution panel

23" Center Mount 4 x CXRC 48-1kW CXCM Integrated bullet type breakers and GMT fuse option

19" Shelf Systems

(Flush Mount) Cordex 5kW bulk power system with plug in controller.

(Flush Mount) Cordex 6kW bulk power system.

23" Shelf Systems

(Center Mount) Cordex 4kW shelf power system with plug in controller and bullet type breaker distribution.

19" Shelf Systems

Mechanical

Dimensions (in/mm): 6.9 x 17.5 x 11.9 / 177 x 444 x 302

weight (lb/kg): 16.5 / 7.5

Note:Shelf P/Ns DO NOT include rectifier modules or distribution breakers.Weights DO NOT include modules.Dimensions DO NOT include mounting brackets.

23" Shelf SystemsMechanical

Dimensions (in/mm): 6.9 x 21.4 x 11.9 / 177 x 543 x 302

weight (lb/kg): 22.5 / 10.2

Note:Shelf P/Ns DO NOT include rectifier modules or distribution breakers.Weights DO NOT include modules.Dimensions DO NOT include mounting brackets.

Communication Ports

can: Interface to control rectifiers

ethernet: 10/100 Base-T for TCIP/SNMP features

Cordex 48V-1kW Shelf System

16

DC

Rec

tifi

ers

cordex™ 1.8kwModular Switched Mode Rectifier and Shelf

> Available in 37.5A @ 48Vdc

> High power density, fan cooled

> Power limiting and wide range AC input

> 91% efficiency and power factor correction

> Bulk 48Vdc power systems up to 9kW

cordex 1.8kw

Electrical

nominal input Voltage: 208 to 277Vac

operating input Voltage: 176 to 312Vac

extended input Voltage: 176 to 90Vac (derated power)

input Frequency: 45 to 66Hz

Power output: 1800W continuous/module

Power Factor: >0.99 (50 to 100% load)

THD: <5%

efficiency: >91%

output Voltage: 42 to 60Vdc

output current: 33.3A @ 54Vdc (37.5A max 48V)

load regulation: <±0.5% (static)

line regulation: <±0.1% (static)

Transient response: ±2% for 50 to 100% load step, 2ms recovery time

Noise

Voice band: <32dBrnC

wide band:<30mVrms (10kHz to 10MHz), <150mVp-p (10kHz to 100MHz)

Psophometric: <1mV

acoustic: <60dBA @ 1m / 3ft

Mechanical

Dimensions (in/mm): 3.3 x 3.94 x 9.25 / 84 x 100 x 235

weight (lb/kg): 6.2 / 2.8

Features

indicators:AC mains OK — green LEDModule OK — green LEDModule fail — red LED

controls: CAN interface to CXC Controller

adjustments (via cXc controller):

Float voltage, Equalize voltage, High voltage alarm, Low voltage alarm, High voltage shutdown, Current limit, Slope, Start delay timers

Protection:

Current limit/short circuit, Start delay, Input/output fuses, Output high voltage shutdown, Power limiting, Thermal foldback/shutdown, Input transient, AC low line foldback/shutdown, AC high voltage shutdown

Environmental

operating Temperature: -40 to 65°C / -40 to 149°F

Storage Temperature: -40 to 85°C / -40 to 185°F

Humidity: 0 to 95% non-condensing

elevation: -500 to 2800m / -1640 to 9186ft

Heat Dissipation: <608BTU per hour

Standards

Safety:

CSA C22.2 No 60950-1-03UL 60950-1 1st EditionCE markedIEC/EN 60950-1

eMc: ETSI 300 386

emissions:

CFR47 (FCC) Part 15 Class BICES-03 Class BEN55022 (CISPR 22) Class BC-tick (Australia)EN 61000-3-2EN 61000-3-3

immunity:

EN 61000-4-2EN 61000-4-3EN 61000-4-4EN 61000-4-5EN 61000-4-6EN 61000-4-11ANSI/IEEE C62.41 Cat B3

19" and 23" Shelf Systems

Mechanical

Dimensions (in/mm): 3.5 x 17.2 x 12.2 / 89 x 438 x 310

Mounting: 19" flush or center mount, 23" center mount only

weight (lb/kg): 19 / 8.5

23" Shelf Systems

Mechanical

Dimensions (in/mm): 3.5 x 21.3 x 12.2 / 89 x 541 x 310

Mounting: 23" flush or center mount

weight (lb/kg): 22 / 10

Connections

input: Terminal Block. Mini-fit connectors (23" only)

output: Bus adapters with ⅜" on 1" centers

chassis ground: ¼" studs on ⅝" centers

can communication: RJ12 offset

Rectifiers Controllers Distribution

19" Flush Mount 3 x CXCR 48-1.8kW CXCM

Bulk power for external distribution panel

19" Flush Mount 4 x CXCR 48-1.8kW CXCI

23" Center Mount 4 x CXCR 48-1.8kW CXCM

23" Center Mount 5 x CXCR 48-1.8kW CXCI

Cordex 48-1.8kW

Typical 7.2kW 23" Shelf with CXCM2

17

DC

Rec

tifiers

cordex™ 3.6kwModular Switched Mode Rectifier

cordex 3.6kw

Electrical

nominal input Voltage: 208 to 277Vac

operating input Voltage: 176 to 312Vac

extended input Voltage: 176 to 90Vac (derated power)

input Frequency: 45 to 70Hz

Power output: 3600W continuous/module

Power Factor: >0.99 (50 to 100% load)

THD: <5%

efficiency: >92%

output Voltage: 42 to 60Vdc

Flood Voltage: 48 to 58Vdc

output current: 66A @ 54Vdc (75A max 48V)

load regulation: <±0.5% (static)

line regulation: <±0.1% (static)

Transient response: ±2% for 50 to 100% load step, 2ms recovery time

Noise

Voice band: <32dBrnC

wide band:<30mVrms (10kHz to 10MHz), <150mVp-p (10kHz to 100MHz)

Psophometric: <1mV

acoustic: <60dBA @ 1m / 3ft

Mechanical

Dimensions (in/mm): 6.3 x 3.4 x 11.8 / 160 x 87 x 300

weight (lb/kg): 10 / 4.6

Features

indicators:AC mains OK — green LED Module OK — green LED Module fail — red LED

controls: CAN interface to CXC Controller

adjustments (via cXc controller):

Float voltage, Equalize voltage, High/Low voltage alarm, High voltage shutdown, Current limit, Slope, Start delay

Protection:

Current limit/short circuit, Start delay, Input/output fuses, Output high voltage shutdown, Power limiting, Thermal foldback/shutdown, Input transient, AC low line foldback/shutdown

Environmental

operating Temperature: -40 to 65°C / -40 to 149°F

Storage Temperature: -40 to 85°C / -40 to 185°F

Humidity: 0 to 95% non-condensing

elevation: -500 to 4000m / -1640 to 13120ft

Heat dissipation: <1176BTU per hour

Standards

Safety:

CSA C22.2 No 60950-1-03UL 60950-1 1st EditionCE markedIEC/EN 60950-1

eMc: ETSI 300 386

emissions:

CFR47 (FCC) Part 15 Class BICES-03 Class BEN55022 (CISPR 22) Class BC-tick (Australia)EN 61000-3-2EN 61000-3-3

immunity:

EN 61000-4-2EN 61000-4-3EN 61000-4-4EN 61000-4-5EN 61000-4-6EN 61000-4-11ANSI/IEEE C62.41 Cat B3

nebS:GR-1089 CORE GR-69 CORE

> Available in 75A @ 48Vdc

> High power density, over 21kW per 23" shelf

> Power limiting and wide range AC input

> High efficiency and power factor correction

> Hot swappable, 4RU ultra compact design

Cordex 48-3.6kW

18

DC

Po

wer

Sys

tem

s

> 2000 to 8000A Capacity

> Designed for central offices and cable headend facilities

> Cordex 3.6kW modular rectifiers

> Circuit breaker and TPL fuse options

> Internal Bay-to-Bay copper busswork

> Expandable power and distribution bays

cordex 48V 8000a Power Systems

Electrical

ac input:Single Phase, 208 to 277Vac Dual 3 Phase, 208 to 240Vac (w/o neutral) Dual 3 Phase, 360 to 480Vac (with neutral)

rectifier Voltage:208 to 277Vac45 to 70Hz

Max. bus capacity:8000A system bus 2000A per bay

Distribution

Fuses - TPl: 2 position, 100 to 800A

Breakers

gJ/gJ1P:1 pole up to 225A 2 pole 250 to 400A 3 pole 450 to 700A

Output termination

TPl Fuse:2 hole ½" dia. on 1¾" centers or 2 hole ⅜" dia. on 1" centers

gJ breaker: 1 pole and 2 pole are ⅜” on 1” centers, 3 pole are 2 hole, ½” dia. on 1¾” centers or ⅜” dia. on 1” centers

ground bar:Overhead buss ground, 15 sets of 2 hole ½" dia. on 1¾" centers (basic system)

Mechanical

enclosure: 1.095mm (14 gauge) steel

Mounting:Standard 23" relay rack (flush rackmount) in box bay

Dimensions (in/mm): 84 x 28 x 28 / 2133 x 710 x 710

weight (lb/kg): Approx. 600 / 272 per bay (no rectifiers)

Environmental

Temperature: 0 to 50°C / 32 to 122°F

Humidity: 0 to 95% non-condensing

elevation: -500 to 2800m / -1640 to 9186ft

Features

System level alarms/controls:Alarms/control parameters are user-programmable through built-in digital supervisory unit

indicators:

LCD with touch screen System OK — green LED System minor alarm — yellow LED Systemmajoralarm—redLED

load Disconnect: 48Vdc/1200A x N mounted on load side

Alarm

connections: 0.34 to 2.5mm2 (14 to 22AWG)

Smart Peripheral Modules

Shunt Mulitplexer: 16 shunts per module

battery cell Monitor: 1 string, 2V cells per module

battery cell Monitor: 4 strings, 12V blocks per module

cordex™ System48V 8000A Power Systems

Cordex 48V 4000A

19

DC

Po

wer S

ystems

> Up to 2000A systems

> Cordex modular rectifiers

> User-configurable, modular distribution tiers

> Intelligent system control and communication

cordex 48V 2000a Power Systems

Electrical

ac input:Single Phase, 208 to 277Vac Dual 3 Phase, 208 to 240Vac (w/o neutral) Dual 3 Phase, 360 to 480Vac (with neutral)

rectifier Voltage: 208 to 277Vac 45 to 70Hz

output Voltage: 42 to 58Vdc (Cordex rectifiers)

output current: 66A @ 54Vdc per 3.6kW rectifier

Power: 21.6kW per rectifier shelf

Max. bus capacity:2000A system bus 600A max. per distribution tier

Mechanical

Dimensions (in/mm): 84 x 28.1 x 19 / 2133 x 714 x 483

weight (lb/kg):Approx. 902 / 410 with 4 tier distribution center and 5 fully loaded Cordex shelves

Environmental

Temperature: 0 to 50°C / 32 to 122°F

Humidity: 0 to 95% non-condensing

elevation: -500 to 2800m / -1640 to 9186ft

Related Components

rectifiers:

Choose up to six Cordex 48V rectifiers per shelf Choose up to six field-expandable shelves per system

low Voltage Disconnect:LVD optional 48Vdc/600A (one per distribution tier)

Distribution:Choose distribution center for 1 tier, 2 tier or 4 tierTerminations (breaker options for tiers 1 through 4)

aM-type/TPS bullet Style: 2 x ¼-20 studs on ⅝" centers per pole

gJ breaker:2 x ⅜-16 studs on 1" centers per pole; i.e., 2-pole breaker will have two sets

cordex controller: The system’s monitoring and control center

battery options:2V Battery cell monitor (1 string) 12V Battery cell monitor (4 strings) Battery tray with breaker (12V blocks)

Tier 1 can be equipped with:24-position AM-type bullet style breakers * 20-position bullet style breakers* with LVD

Tiers 2 to 4 can be equipped with:24-position AM-type bullet style breakers* 20-position bullet style breakers* with LVD 3-position GJ (with or without LVD)

* Bullets style TPS fuse holder and GMT fuse blocks available

cordex™ System48V 2000A Power Systems

Cordex 48V 2000A

3 positions gJ breaker tier rated at 600 amps

3 positions gJ breaker tier with lVD rated at 600 amps

24 position bullet breaker tier rated at 600 amps

20 position bullet breaker tier with lVD rated at 600 amps

20

DC

Po

wer

Sys

tem

s

cXPS 48-1T48V 375A Power Systems

> 48Vdc systems using high density 3.6kW rectifiers

> Front access DC connections

> CXCM4 advanced modular controller

> Flexible integrated rack options

> Optional DC to DC converter upgrade kits

> Integrated system shunt and LVD

cXPS 48-1T

Configurations

053-392-20-000: Base system with 23" mounting

053-392-20-010: System mounted in 22RU (½ height) battery mount rack

053-392-20-020: System mounted in 44RU Zone 4 seismic rack

053-392-20-030: System mounted in 44RU Zone 4 seismic rack with 3x battery trays for 3x 48V strings

rectifier: Up to 5x 48V-3.6kW rectifier positions

Distribution:

18x AM plug-in breaker positions 10x GMT type fuse positions Shunt Low voltage disconnect

controller: CXCM4 modular controller

Electrical

input Voltage: 176 to 320Vac

current: 16.8A @ 240Vac nominal (per rectifier module)

Frequency: 45 to 66Hz

Power Factor: >0.99

output Voltage: 42 to 60Vdc

current:System:375A (expandable to 600A with additional CXRF shelf) Rectifier:75A@48Vdc

Power:System:18kW (expandable to 28.8kW with additional CXRF shelf) Rectifier:3600Wmax

Environmental

Temperature:-40 to 65°C / -40 to 146°F -40 to 75°C / -40 to 167°F derated output

Humidity: 0 to 95% non-condensing

elevation:-500 to 2800m / -1640 to 9186ft -500 to 4000m / -1640 to 13124ft with derated output

Mechanical

Dimensions (in/mm): 19.25 x 23 x 18.8 / 488 x 584 x 477

Mounting: 23" center mount

weight (lb/kg): 110 / 49.8

Connections

load breaker:Hot:¼"-20studson⅝" centers Return:¼"holeson⅝" centers

gMT Fuses: Screw terminal 1.31mm2 to 0.128mm2 (#16 to #26 AWG)

battery Terminations:⅜" holes on 1" centers 4x Sets per polarity

rectifier input: ⅜" holes on 1" centers

alarm connections: Screw terminal 1.31mm2 to 0.128mm2 (#16 to #26 AWG)

access:Cable:toporbottom User:frontaccessafterinstallation

Related Components

010-567-20: Cordex 48V-3.6kW rectifier

038-276-20: CSM02 DC-DC converter kit

CXPS 48-1T Internal Distribution

CXPS 48V 375A

21

DC

Po

wer S

ystems

cXPS 48-2T48V 825A Power Systems

> 48Vdc systems using high density 3.6kW rectifiers

> Front access DC connections

> CXCM4 advanced modular controller

> Flexible integrated rack options

> Optional DC to DC converter upgrade kits

> Integrated system shunt and LVD

cXPS 48-2T

Configurations

053-392-20-000: Base system with 23" mounting

053-392-20-010: System mounted in 22RU (½ height) battery mount rack

053-392-20-020: System mounted in 44RU Zone 4 seismic rack

053-392-20-030: System mounted in 44RU Zone 4 seismic rack with 3x battery trays for 3x 48V strings

rectifier: Up to 11 x 48V-3.6kW rectifier positions

Distribution:

38x AM plug-in breaker positions 10x GMT type fuse positions Shunt Low voltage disconnect

controller: CXCM4 modular controller

Electrical

input Voltage: 176 to 320Vac

current: 16.8A @ 240Vac nominal (per rectifier module)

Frequency: 45 to 66Hz

Power Factor: >0.99

output Voltage: 42 to 60Vdc

current:System:825A (expandable to 1200A with additional CXRF shelf) Rectifier:75A@48Vdc

Power:System:39.6kW (expandable to 57.6kW with additional CXRF shelf) Rectifier:3600Wmax

Environmental

Temperature:-40 to 65°C / -40 to 146°F -40 to 75°C / -40 to 167°F derated output

Humidity: 0 to 95% non-condensing

elevation:-500 to 2800m / -1640 to 9186ft -500 to 4000m / -1640 to 13124ft with derated output

Mechanical

Dimensions (in/mm): 29.7 x 23 x 18.8 / 755 x 584 x 477

Mounting: 23" center mount

weight (lb/kg): 155 / 70.3

Connections

load breaker:Hot:¼"-20studson⅝" centers Return:¼"holeson⅝" centers

gMT Fuses: Screw terminal 1.31mm2 to 0.128mm2 (#16 to #26 AWG)

battery Terminations:⅜" holes on 1" centers 4x Sets per polarity

rectifier input: ⅜" holes on 1" centers

alarm connections: Screw terminal 1.31mm2 to 0.128mm2

(#16 to #26 AWG)

access:Cable:toporbottom User:frontaccessafterinstallation

Related Components

010-567-20: Cordex 48V-3.6kW rectifier

038-276-20: CSM02 DC-DC converter kit

CXPS 48-2T Internal Distribution

CXPS 48V 825A

22

DC

Co

nver

ters

cSM01 and cSM02Modular DC to DC Converters

> 48Vdc to 24Vdc, 10A output

> 24Vdc to 48Vdc, 5A output

> Accommodates up to six, 10A power modules per system

> Isolated input and output

> Optional supervisory control module

> Scalable hot plug-in operation

> Convection cooled

cSM01 and cSM02 nominal Specifications

Noise

Voice band: <22dBrnC

wide band:<10mVrms (10kHz to 10MHz), <150mVp-p (10kHz to 100MHz)

acoustic: 45dBA at 1m (3ft)

Environmental

Temperature:0 to 50°C / 32 to 122°F with specified ventilation, -40 to 50°C / -40 to 122°F (optional)

Humidity: 0 to 95% non-condensing

elevation: -500 to 2800m / -1640 to 9186ft

Features

indicators:

Power on Output over voltage protection trip Bar graph output current Converter fail Current limit Circuit breaker trip

alarms:Converter fail alarm* Circuit breaker trip alarm*

adjustments: Output voltage

Distribution Fuse

indicators: Output fuse fail

alarms: Output fuse alarm*

Fuse block: 8 position 0 to 10A GMT fuses (50 and 60A versions), 4 position 0 to 10A GMT fuses (20A version)

connections: Terminal block 0.75 mm2 to 4 mm2 (#18 to #12 AWG)

Protection:

Input fuse Input inrush current limiting Over temperature limiting Input high and low voltage shutdown Output paralleling diode Current limit/short circuit protection

Analog Supervisory

indicators:

System over voltage protection trip System high voltage alarm Majoralarm System low voltage alarm Test mode Digital voltmeter/ammeter

alarms:Majoralarm* Low voltage alarm* High voltage alarm*

adjustments:

Over voltage protection High voltage alarm Low voltage alarm Test/normal selector

* Jumper selectable form A/B contacts

Mechanical

input/output: Two ¼" studs on ⅝" centers

alarm/control: Terminal block, 0.5mm2 to 1.5mm2 (#20 to 16AWG)

10A (2 Module Horizontal 19")

weight (lb/kg): 18.5/8.4 w/ 2 power modules

Dimensions (in/mm): 3.5 x 17 x 12 / 90 x 432 x 305

15A (3 Module Horizontal 23")

weight (lb/kg): 24/10.9 w/ 3 power modules

Dimensions (in/mm): 3.5 x 20 x 12 / 90 x 508 x 305

20A (2 Module Horizontal 19"

weight (lb/kg): 18.5/8.4 w/ 2 power modules

Dimensions (in/mm): 3.5 x 17 x 12 / 90 x 432 x 305

25A (5 Module Horizontal 19")

weight (lb/kg): 36/16.6 w/ 5 power modules

Dimensions (in/mm): 7 x 17 x 12 / 178 x 432 x 305

30A (6 Module Horizontal 23")

weight (lb/kg): 43/19.5 w/ 6 power modules

Dimensions (in/mm): 7 x 20 x 12 / 178 x 508 x 305

30A (3 Module Horizontal 23")

weight (lb/kg): 24/10.9 w/ 3 power modules

Dimensions (in/mm): 3.5 x 20 x 12 / 90 x 508 x 305

50A (5 Module Horizontal 19")

weight (lb/kg): 36/16.6 w/ 5 power modules

Dimensions (in/mm): 7 x 17 x 12 / 178 x 432 x 305

60A (6 Module Horizontal 23")

weight (lb/kg): 43/19.5 w/6 power modules

Dimensions (in/mm): 7 x 20 x 12 / 178 x 508 x 305

Electrical

input Voltage: 20 to 30Vdc 40 to 60Vdc

output Voltage: 44 to 52Vdc 22 to 26Vdc

output current: 5A 10A

efficiency: >85% (100% load) >85% (100% load)

regulation:-1%, ±0.1% load (static), ±0.1% line (static), <2%

deviation for 50 to 100% load step (dynamic)

response Time: 2 ms to 0.1% of output for 50 to 100% load step

Standards

en: 55022 - Class A (radiated)

Fcc: Part 15 Class A (radiated)

CSM02

23

Distribution centers

> Various modular distribution configurations

> Complete front access

> Integrated Cordex™ system controller

> Integrated shunt and LVD options

> AM plug-in breaker, GJ breaker and GMT fuse options

Distribution Panel overview

Part Number

Fuse Position

Fuse Type

Breaker Position

Breaker Type

Capacity MountingFront Access

RUAdditional Options

universal Distribution centers

020-584-20 16* TPS* 16AM Plug-In

400A 19/23 Partial 4Controller, LVD, Shunt, Batt Disconnect

Vista Distribution centers

020-645-2020-24* 10

TPS* GMT

20-24AM Plug-In**

800A 23 Yes 7Controller, LVD, Shunt

020-646-2040-48* 10

TPS* GMT

40-48AM Plug-In**

1000A 23 Yes 9Controller, LVD, Shunt

020-635-2080-96* 10

TPS* GMT

80-96AM Plug-In**

2000A 23 Yes 17Controller, LVD, Shunt

Modular Distribution Tier Options

Single Voltage:

24 Position AM plug-in (TPS plug in available) 20 Position AM plug-pn w/ 600A LVD 3 Position GJ 3 Position GJ w/ 600A LVD

Dual Voltage:

12x Primary and 10x secondary (AM plug-in) 16x Primary and 6x secondary (AM plug-in) 8x Primary (w/ LVD) and 10x secondary (AM plug-in) 12x Primary (w/ LVD) and 6x secondary (AM plug-in)

Notes:* TPS Fuses with AM plug-in breaker cartridges may be used as alternative to breakers** Compatible with multiple pole AM plug-in breakers (110 to 250A)

Vista Two Tier UDC

Universal Distribution Center

DC

Distrib

utio

n Cen

ters

24

DC

Acc

esso

ries

Dc accessories

gMT Fuse Panels

GMT 50 Series

19"/23" rackmount, 1RU highFlush mount and center positionsStandardcapacity:50AperinputBright, color coded LED indicators for A/B input power status, A/B fuse failure alarmsForm-C alarm contacts for A/B input power fail, A/B fuse fail (4 relays)Singleinputanddualinput: •10GMToutput •10A/10Boutput •20GMToutput

GMT 100/High Capacity Series

19"/23" rackmount, 1RU highFlush mount and center positionsBright, color coded LED indicators for A/B input power status, A/B fuse failure alarmsSingle input, A/B insolated input and A/B/C redundant configuration availableIncluded LED indicators, form-C alarm contacts

100 SeriesHighpowerdensityandampacity: •100Aperinput:(singleinput,A/Binput) •70A:(A/B/C-source)Form-C alarm•16GMToutputs •16A/16BGMToutputs C-output diode routed, 32 fused redundant outputs

High capacity Series24 GMT fuse sockets150A input bus ratingConfigurationsinclude:•Singleinput,24fuses•A/Binput,12A/12B fuses, A/B/C version, 24 fuses

TPA Fuse Panel

1RU, 19"/23" rackmountSingle input, A/B isolated input and A/B/C redundant configurations available12 TPA fuse sockets200A input bus ratingIncludes LED indicators, form-C alarm contacts

curcuit breaker Panel

KTK Fuse Panel

19"/23" rackmount, 1RU highHigh power densityHighampacity:120AperA/BinputBright, color coded LED indicators for A/B input power status, A/B fuse failure alarmsForm-C alarm contacts for A/B input power fail, A/B fuse fail (4 relays)Dualinput:4A/4BandKTK30Afuseoutputs

HDDC: High Density

19"/23" rackmount, 3RU highSingle inputA/B isolated inputA/B inputC-output redundant diode routedHigh breaker count to support VOD server redundant power supply circuit requirements and combined high current loadHighpowerdensityandampacity: •200Aperinput:(singleinput,A/Binput) •200Acombinedload:(A/B/C-source)Accepts up to 22 plug-in bullet terminal circuit breakersAlphanumeric LCD display for voltage, load current per bus, breaker status Form-CalarmcontactsforMajorandMinoralarms

> Rackmount power sources including integrated distribution fuses save space and provide flexibility

> Distribution systems from 50A GMT fuse panels to 800A circuit breaker distribution centers

> 19"/23" universal rackmount

HDDC:HighDensity

25

DC

Accesso

ries

Dc accessories

DCX Series

400, 600, 800, 1000 and 1200A modelsDirect Battery Terminal mounting options for most battery configurations. Bus adapter and hardware kits provided for individual battery cell size configurations.LED indicators for On Line/Off Line status, EPO trip and general fault alarm statusForm-C relay contact output for remote monitoring of statusIntegrated EPO function for remote trip

Super HDX

2RU, 19"/23" rackmountSingle input, A/B insolated input configurations available300A input bus ratingUses AM series bullet terminal circuit breakers (Breaker choices available from 5A to 100A)16 circuit breaker positionNo GMT fuses (unlike standard HDX)Targeted at Cisco 7609 installations

Matrix Breaker Panel

1RU, 19"/23" rackmountSingle input, A/B insolated input and A/B/C redundant configurations available200A input bus ratingUsesnew“slimline”1RUcircuitbreakers(Breakerchoicesavailablefrom 5A to 100A)Includes LED indicators, form-C alarm contactsConfigurationsinclude:•Singleinput,20breakers•A/Binput,10A/10Bbreakers,A/B/Cversion,16breakers

HDX Compact

19"/23" rackmount, 2RU highSingle inputA/B isolated inputHighpowerdensityandampacity: •300Aperinput:(singleinput,A/Binput) •300Acombinedload:(A/B/C-source) •Acceptsupto12plug-inbulletterminalcircuitbreakersStandard unit includes front panel with A and B input LED indicators and breaker/fuse trip indicator LEDForm-CalarmcontactsforMajorandMinoralarms

> Compact, high power density DC distribution fuse panels and circuit breaker panels

> High current, high fuse/breaker count in a small RU footprint

> Battery disconnect for circuit breaker protection of the entire facility DC plant

HDX Compact

26

DC

Accesso

ries

27

Batteries

Headend BatteriesAlpha’s Headend battery line includes three distinct types of models: 20-year batteries, 10-year

telecom front and top terminal, and flame retardant UPS batteries. These batteries provide

improved performance, longer runtimes and extended service life. The front terminal models allow

for easier access to the batteries during installation and routine maintenance. Alpha’s Headend

batteries are ideal for broadband, cellular, electric utility, PCS, customer premise, long distance

and distributed power.

> AlphaGuard™

AlphaGuard monitors and protects your batteries by spreading the charge voltage equally across all

the batteries in the string, ensuring that every battery, whether old or new, is properly charged. With an

ideal voltage across each battery, life and runtime are optimized. Individual batteries in a string can be

replaced as they fail, allowing batteries to be left in service longer.

> Battery Testing EquipmentA fast, reliable and affordable testing process is now available with the development of conductance

based battery measurement technology. By coupling conductance testing with a simple utility load

test, the system operator is armed with the quality of data necessary to know the status of their

installed standby batteries and budget their replacement with confidence.

28

Bat

teri

es

Headend batteries

> 20-year design life batteries with VRLA technology

> 10-year design life batteries with front or top terminals

> High rate flame retardant AGM UPS batteries for all standby applications

10 and 20 year life batteries

C&D MS Endur 345 to 2038Ah

Part number# cells/Module

# Plates/cell

nom ah cap(8hr)

System # of cells

System Voltage

Model Volts

Dimensions (in/mm)weight(lb/kg)

cell layout w x H

raa64024ce01 3 7 345 24 48 6 21.4 x 44.7 x 23.1 / 545 x 1136 x 587.5 1970 / 894 6 X 4

rbb46024ce01 3 9 480 24 48 6 18.7 x 64.5 x 23.1 / 476 x 1642 x 587.5 2470 / 1120 4 X 6

rbb64024ce01 3 9 480 24 48 6 26.1 x 44.7 x 23.1 / 664 x 1136 x 587.5 2410 / 1093 6 X 4

rcc46024ce01 3 11 599 24 48 6 21.4 x 64.5 x 23.1 / 545 x 1642 x 587.5 2920 / 1324 4 X 6

rDF38024ce01 3 15 839 24 48 6 30.4 x 44.7 x 23.1 / 773 x 1136 x 587.5 2850 / 1293 3 X 8

rDF46024ce01 3 15 839 24 48 6 21.4 x 84.4 x 23.1 / 545 x 2148 x 587.5 3860 / 1751 4 X 6

reH38024ce01 3 19 1079 24 48 6 27.9 x 64.5 x 23.1 / 708 x 1642 x 587.5 3790 / 1719 3 X 8

reH46024ce01 3 19 1079 24 48 6 26.1 x 84.4 x 23.1 / 664 x 2148 x 587.5 4740 / 2150 4 X 6

rFK38024ce01 3 23 1319 24 48 6 33.5 x 64.5 x 23.1 / 850 x 1642 x 587.5 4670 / 2118 3 X 8

rFK46024ce01 3 23 1319 24 48 6 30.4 x 84.5 x 23.1 / 773 x 2148 x 587.5 5620 / 2549 4 X 6

rHP38024ce01 3 27 1559 24 48 6 39.5 x 64.5 x 23.1 / 1004 x 1642 x 587.5 5550 / 2517 3 X 8

rHP46024ce01 3 27 1559 24 48 6 34.4 x 84.4 x 23.1 / 875 x 2148 x 587.5 6550 / 2971 4 X 6

rJS38024ce01 3 35 2038 24 48 6 45.5 x 64.5 x 23.1 / 1157 x 1642 x 587.5 6540 / 2966 3 X 8

rJS46024ce01 3 35 2038 24 48 6 43.6 x 84.4 x 23.1 / 1108 x 2148 x 587.5 8320 / 3774 4 X 6

East Penn Unigy II 760 to 2000Ah

Part number# cells/Module

# Plates/cell

nom ah cap(8hr)

System # of cells

System Voltage

Model Volts

Dimensions (in/mm)weight(lb/kg)

cell layout w x H

24aVr95-17 3 17 760 24 48 6 21.9 x 68.3 x 27.1 / 556 x 1735 x 689 3260 / 1479 3 x 8

24aVr95-19 3 19 855 24 48 6 24.2 x 68.3 x 27.1 / 613 x 1735 x 689 3612 / 1638 3 x 8

24aVr95-21 3 21 950 24 48 6 26.4 x 68.3 x 27.1 / 671 x 1735 x 689 3956 / 1794 3 x 8

24aVr95-23 3 23 1045 24 48 6 28.7 x 68.3 x 27.1 / 728 x 1735 x 689 4308 / 1954 3 x 8

24aVr95-25 3 25 1140 24 48 6 30.1 x 68.3 x 27.1 / 785 x 1735 x 689 4652 / 2110 3 x 8

24aVr95-27 3 27 1235 24 48 6 33.2 x 68.3 x 27.1 / 842 x 1735 x 689 4972 / 2255 3 x 8

24aVr95-29 3 29 1330 24 48 6 35.4 x 38.3 x 27.1 / 899 x 1735 x 689 5348 / 2426 3 x 8

24aVr95-31 3 31 1425 24 48 6 37.7 x 68.3 x 27.1 / 956 x 1735 x 689 5668 / 2571 3 x 8

24aVr95-33 3 33 1520 24 48 6 39.9 x 68.3 x 27.1 / 1013 x 1735 x 689 6020 / 2737 3 x 8

24aVr125-33 2 33 2000 24 48 4 53.2 x 71.4 x 28.6 / 1351 x 1814 x 727 8616 / 3908 (2x6)x2

Note:Add“S”forStandardPolypropyleneor“L”forFlameRetardantPolypropylenes,suffixtomodulenumber.(ex.24AVR95-17-S)

GNB Absolyte IIP 696 to 1600Ah

Part number# cells/Module

# Plates/cell

nom ah cap(8hr)

System # of cells

System Voltage

Model Volts

Dimensions (in/mm)weight(lb/kg)

cell layout w x H

100a-15 3 15 696 24 48 6 22.2 x 72.7 x 26.4 / 563 x 1846 x 670 2992/1357 3 x 8

100a-17 3 17 800 24 48 6 24.5 x 72.7 x 26.4 / 622 x 1846 x 670 3392/1539 3 x 8

100a-19 3 19 896 24 48 6 26.8 x 72.7 x 26.4 / 679 x 1846 x 670 3760/1706 3 x 8

100a-21 3 21 1000 24 48 6 29 x 72.7 x 26.4 / 737 x 1846 x 670 4120/1869 3 x 8

100a-23 3 23 1096 24 48 6 31.3 x 72.7 x 26.4 / 794 x 1846 x 670 4488/2036 3 x 8

100a-25 3 25 1200 24 48 6 33.5 x 72.7 x 26.4 / 851 x 1846 x 670 4864/2206 3 x 8

100a-27 3 27 1296 24 48 6 35.8 x 72.7 x 26.4 / 908 x 1846 x 670 5224/2370 3 x 8

100a-29 3 29 1400 24 48 6 38 x 72.7 x 26.4 / 965 x 1846 x 670 5632/2555 3 x 8

100a-31 3 31 1496 24 48 6 40.3 x 72.7 x 26.4 / 1022 x 1846 x 670 6000/2722 3 x 8

100a-33 3 33 1600 24 48 6 42.5 x 72.7 x 26.4 / 1080 x 1846 x 670 6360/2885 3 x 8

Note:Add“L”forFlameRetardantPolypropylenes,suffixtomodulenumber(ex.100A-31-L).

MsEndur

29

Batteries

Headend batteries

> Take advantage of your cable buying power on batteries

> Alpha offers cable companies the most competitive pricing on UPS and DC plant batteries including C&D, GNB and East Penn 10 and 20 year VRLA batteries

> Alpha Technical Services offers removal, replacement and recycling of UPS Batteries

> Most UPS brands serviced

Front and Top Terminal batteries

East Penn ET Series

Part number Model Volts capacity @ 8hr rate @ 1.75V/c Dimensions (in/mm) weight (lb/kg) Terminal Type

12aVr100-3eT 12 96 20.1 x 4.3 x 9.4 / 510.5 x 109.2 x 238.7 75 / 34 Threaded Insert

12aVr150-eT 12 150 22 x 4.9 x 11.75 / 558.8 x 124.5 x 298.5 115 / 52 Threaded Insert

GNB Marathon

Part number Model Volts capacity @ 8hr rate @ 1.75V/c Dimensions (in/mm) weight (lb/kg) Terminal Type

M12V90FT 12 90 156 x 4.1 x 10.6 / 395 x 105 x 270 68 / 31 Threaded Insert

M12V105FT 12 104 20.1 x 4.3 x 9.4 / 511 x 110 x 238 79 / 35.8 Threaded Insert

M12V125FT 12 125 22 x 4.9 x 11.1 / 559 x 124 x 283 105 / 47.6 Threaded Insert

M12V155FT 12 155 22 x 4.9 x 11.1 / 559 x 124 x 283 119 / 53.8 Threaded Insert

AlphaCell™ SMU-F

Part number Model Volts capacity @ 8hr rate @ 1.75V/c Dimensions (in/mm) weight (lb/kg)Top access Stud Hole Size

Front access Stud Size

SMu12-155Fr 12 150 21.9 x 4.9 x 11.1 / 558 x 125 x 283 119 / 54 8mm 6mm

SMu12-170Fr 12 172 21.9 x 4.9 x 12.2 / 558 x 124 x 310 129.8 / 59 8mm 6mm

Tel Series 10 Year Batteries - Top Terminal

Part number Model Volts capacity @ 8hr rate @ 1.75V/c Dimensions (in/mm) weight (lb/kg) Terminal Type

Tel12-30 12 30 7.8 x 5.2 x 6.8 / 197.4 x 131.9 x 172.7 27 / 12 Threaded Insert

Tel12-45 12 46 8.9 x 5.4 x 8.1 / 228.3 x 138.9 x 205.6 40 / 18 Threaded Insert

Tel12-70 12 69 10.3 x 6.8 x 8 / 260.5 x 173.4 x 203.6 55 / 25 Threaded Insert

Tel12-80 12 79 12.0 x 6.8 x 8.1 / 305.8 x 173.4 x 205.3 68 / 31 Threaded Insert

Tel12-90 12 88 13.5 x 6.8 x 8.5 / 343.1 x 171.7 x 216.2 72 / 33 Threaded Insert

Tel12-105 12 102 20.1 x 4.3 x 9.4 / 511 x 110 x 238 79 / 36 Threaded Insert

Tel12-125 12 127 13.6 x 6.8 x 10.9 / 344.7 x 171.7 x 277.7 100 / 45 Threaded Insert

Note:SLCversionsavailablewithCableAssemblyTerminalType.Modelnumbersinclude/SLCafterthemodel(ex.Tel12-30/SLC)

AGM UPS - Flame Retardant High Rate Series

Part number Model Volts watts per cell Dimensions (in/mm) weight (lb/kg) Terminal Type

uPS12-100Mr 12 91 6.5 x 5.2 x 6.9 / 166.2 x 131.3 x 174.3 21 / 10 Flag terminal

uPS12-150Mr 12 148 7.8 x 5.2 x 6.8 / 197.1 x 131.9 x 172.7 27 / 12 Threaded Insert

uPS12-210Mr 12 206 9.0 x 5.5 x 8.1 / 228.6 x 139.2 x 205.1 40 / 18 Threaded Insert

uPS12-300Mr 12 300 10.3 x 6.8 x 8.0 / 260.9 x 173.4 x 203.5 57 / 26 Threaded Insert

uPS12-350Mr 12 350 12.0 x 6.8 x 8.1 / 305.8 x 173.4 x 204.8 67 / 30 Threaded Insert

uPS12-400Mr 12 400 13.4 x 6.8 x 8.5 / 340.9 x 172.7 x 216.4 74 / 34 Threaded Insert

uPS12-490Mr 12 488 13.6 x 6.8 x 10.9 / 344.7 x 172.7 x 277.7 10 / 45 Threaded Insert

uPS12-540Mr 12 537 12.6 x 6.9 x 8.9 / 320.8 x 177 x 227.2 100 / 45 Threaded Insert

uPS6-620Mr 6 620 12.6 x 6.9 x 9.9 / 321 x 177 x 253 72 / 33 Threaded Insert

12AVR100-3ET

30

alphaguard

Models

ag-cMT-4: AlphaGuard Charge Management SC, 48V —including 48Vdc battery string interface cable

Configuration

Quantity: One (1) AlphaGuard is required per battery string

Service location: With the battery string

Mechanical

Housing Material: High impact plastic

Dimensions (in/mm): 1.44 x 4.82 x 4.25 / 36 x 122 x 108

weight (lb/kg): 0.8 / .36

Electrical

batteries: Individual 12Vdc nominal batteries configured into 36 or 48Vdc strings

circuit Protection: Single blow fuse, reverse polarity protected

environmental: -40 to 55°C / -40 to 131°F, 5 to 95% humidity

Quiescent current Draw: 1mA max (Current consumed by AlphaGuard after low voltage total shutdown)

charge Management: Most effective during float period of charge

Max current: 2A @ 25°C / 77°F

Quality of Final balance: ±100mV max between any two (2) batteries

charging efficiency: 80 to 90%

charge balance: ±100mV typical

low Voltage cutoff: 34.5Vdc/46Vdc ±5%

communication to XM2: AlphaGuard configured DSM status monitoring card

Voltage Sense regulation: ±100mV

warranty: 5 years

The AlphaGuard employs a patented Charge Management

Technology (CMT) to shuttle excess charge current to batteries

requiring a greater charge. The entire unit is contained in a

small plastic enclosure that installs directly on top of one the

batteries in the string. A short service cable connects the

AlphaGuard to each of the batteries in the string. One

AlphaGuard is required per string.

An AlphaGuard configured with the optional voltage sense

cabling and interface module (DSM, ESM, EDSM or External

DOCSIS®) allows the AlphaGuard to interface with a status-

monitoring module. Two AlphaGuard modules can be

connected to an interface module. Refer to individual interface

module documentation for additional information.

alphaguard™

Battery Charge Management System

> Extends battery life

> Replace single batteries, not the entire string

> Spreads charge voltage equally across batteries

> Compensates for battery differences as they age

> Safe unattended operation designed to CSA C22.2 No. 107.1 and UL 1778 standards

> Optional Potted AlphaGuard available

Optional Battery Cable

48V 6ft

AlphaGuard CMT-4

Bat

teri

es

31

Batteries

battery Testing equipmentAlphaCell™ Battery Testing Equipment

> Complete battery life trending through conductance tests

> Non-intrusive conductance measurements do not reduce string life

> Quick, accurate measurements and data recording reduce on-site time

> Simple pinpoint testing requires only access to two battery posts or straps

> Enables early detection of questionable batteries in the network

battery Testing equipment

Model: Celltron Ultra Celltron Advanced™

Model number:CTU-6000 (w/ temp. sensor)

CTA-4000 (kit) CTA-2000 (analyzer only)

applications:

Tests individual lead acid cells or monoblocs (up to 16V) in any common configuration, approximately 10-6000Ah

Tests individual lead acid cells or monoblocs (up to 16V) in any common configurations

Voltage: 1.5 to 20Vdc 1 to 20Vdc

conductance: 100 to 19990 Siemens 100 to 19990 Siemens

Test Data Storage:500 string locations of 480 test results stored internally

16 string locations of 480 test results stored internally

accuracy: +2% across test range +2% across test range

Voltmeter resolution: 5mVdc 5mVdc

environmental: 0 to 40°C / 32 to 104°F, 95% non-condensing

Conductance Technology/Industry Approvals and Recommendations:

IEEE Standards 1188 and 484EPRI Guide for testing stationary batteries International Telecommunications Energy ConferenceBellcore T1Y1Presentation for American National Standards InstituteInternational Lead Zinc Research OrganizationBattery Council International

Applications

Cable TV/Broadband Power Networks

•OutsidePlantBatteries•HeadendDC/ACBatteries•PremiseBackup Supplies (FTTx)

6/12V, 5 to 600Ah Stationary Batteries

Security system batteries

Emergency lighting batteries

Features and Benefits

Simple - One-steptesting,noinstrumentinputsoradjustmentsrequired.

Quick - Battery voltage and conductance displayed in less than 10 seconds.

Test an entire 48V string in less than 1 minute.

Safe - Utilizes patented conductance technology, a passive method that

minimizes technician risk.

accurate - Field test proven to ±2% accuracy across test range. Conductance

method recognized by IEEE standard for the testing of lead-acid batteries with

proven correlation to battery capacity.

economical - Efficient and accurate battery tester priced to fit into every

technician’s tool kit.

Kit contents

Celltron Ultra Kit CTA-6000AT Celltron Advanced Kit CTA-4000ATcontains:Digital multimeterInfrared strip printerLighted probesClamps and probes

contains:Protective bootRechargeable battery packInfrared PC data receiver and softwareInfrared printerInfrared temperature sensorProtective carrying caseBoth clamp and probe cablesSpare fuses, printer paper, probe tips

Optional Equipment:

Handheld PrinterInfrared Module for PC

Celltron UltraCTU-6000

32

DC

to

AC

Inve

rter

s

33

DC

to A

C Inverters

DC to AC InvertersAlpha Technologies offers a full line of modular inverter systems providing a new level of scalability, maintainability, compactness, reliability and performance. Alpha’s scalable DC to AC inverter is recognized as the industry standard for critical AC power by many of the world’s leading communications companies.

> SMI 3300 Inverter SeriesSMI 3300 inverter modules are hot swappable and readily accessible, leading to an extremely low mean time to repair and easy system expansion for increased power and/or redundancy. Advanced PWM switchmode technology as well as thorough input and output filtering results in a highly efficient, compact and quiet telecom grade inverter system with excellent dynamic response characteristics.

> TEBEVERT Inverter SeriesThe TEBEVERT DSP inverter system featuring Digital Signal Processing technology can be used in a wide array of telecommunications and industrial applications. The introduction of enhanced DSP controls and higher semi-conductor switching frequencies improves power density and operating efficiency while dramatically reducing physical size and weight.

> INEX Inverter SystemINEX inverter series is an integrated telecommunication power system, including inverter, static switch, LCDdisplaycontroller,andinterfacemodules.Withversatile“buildingblock”designandN+1redundant configuration, the INEX inverter system facilitates complex telecommunication and industrial power demands and provides ultimate flexibility for your current and future requirements. N+1 parallel redundancyallowspowercapacityexpandableupto24kVA.INEX“allmaster”dynamicmechanismautomatically shares and re-organizes critical loads to prevent interruption should any inverter module fail. The DSP-microprocessing controller gives real-time system status through comprehensive LCD display, and allows program settings through the display panel. With a communication interface module installed, you can further control and monitor the system remotely.

> S4 Inverter SeriesAlpha’s S4 3.5kVA inverter power modules can be stacked in an N+1 redundant configuration for optimum reliability up to 21kVA. This modular scalability makes the S4 ideal for overlay applications wherefuturepowergrowthisanticipated.Allmodulesarepackagedintoa“hotswap”receivercabinetallowing rapid and safe exchange of any component without interruption to the critical load.

> DSP Inverter SeriesThe DSP inverter system is designed to address the critical AC powering requirements of telecommunications applications, Voice over Internet Protocol (VoIP) and servers. The system can be scaled in 1kVA or 2.5kVA increments up to 27.5kVA in an N+1 redundant configuration. These units have been NEBS Level 3 Certified by a nationally recognized testing lab to meet the stringent requirements of the telecommunications industry.

> S5 Inverter SeriesAlpha’s S5 is designed for telecommunication, IT and industrial applications. The S5 inverter packs 1500W of power into a light and compact package that is 19" rackmountable and 1RU, with four models for different input (24 and 48Vdc) and output (115 and 230Vac) voltage combinations. Features include an integrated controller and an optional internal Static Transfer Switch, enabling flexible and scalable systems for true plug and play with no external subsystems needed.

> MS Power Inverter SeriesMS Inverters feature an integrated utility bypass, and can be cascaded for redundancy. Designed for long mean time between failure, these inverters provide the dependable AC power your networks demand. The compact 2RU mounting package makes this model the right selection for limited space applications. These intelligent, dependable inverters provide economical AC power for all of your network needs.

34

SMi 3300 inverter Series3.3 to 52.8kVA Inverter System

> Scalable system size from 3.3 to 52.8kVA

> Hot swappable and readily accessible

> Advanced PWM switchable technology

SMi 3300 inverter Series

Electrical

output waveform:True sine wave, <1% distortion (unity PF) <3% distortion(3:1crestfactortestload)

output Voltage/frequency

SMi-3300-12060: 120Vac/60Hz nominal

SMi-3300-24050: 240Vac/50Hz nominal

output Power:3300VA / 2750W, with 120% continuous overload capability

load-line regulation: Within ±2.5% combined

crest Factor Handling: 3:1

input Voltage: -48Vdc nom; accepts 42 to 60Vdc range

input current: Nominalfullload:60A@54Vdc

battery Feedback noise: <30dBrnC

efficiency: >90% from 50 to 100% full load

Protection :

Reverse DC polarity protection, output short circuit/ over current protection, over temperature, DC input magnetic circuit breaker, DC input low voltage shutdown

leD indicators:Battery On/Reversed, Inverter On/Fail, Tri-level inverter loading indicator

approvals:UL 1778 Listed, CE Mark on 50Hz version FCC Class A subpart 15J, EN55022 Class A

Mechanical

Module Dimensions (in/mm): 5.13 x 9.38 x 14.25 / 130 x 238 x 362

Mounting: “MSeries”cageassemblies

Module weight (lb/kg): 20.5 / 9.3

Finish: Black fine texture powder coat

Environmental

operating Temperature: 0 to 50°C / 32 to 122°F (Forced-air fan cooling)

Humidity: 0 to 95% non-condensing

elevation: 3000m / 10000ft before derating

noise: <51dBA at 1 meter

Heat output: 1403BTU/hr per module at full load

Cage Assemblies and Other Inverter System Components

Cages to Fit in Any 19/23" Rack Space

“M Series” cage assemblies are available that house up to 2, 3, or 4 SMi3300 inverter modules. The M6.6 is a low profile, 23" rackmount, module unit. The M9.9 is a 19" rackmount, 3 module unit and the M13.2 is a 23" rackmount, 4 module unit. all cage assemblies are 22" (559 mm) deep.

Fully Equipped Single Cage Inverter Systems

The “-F” cage assemblies are fully equipped with automatic bi-directional transfer logic, a fast “eTS” transfer switch and alarm logic to comprise a single cage inverter system. all Dc input, ac in/out and alarm connections are made via rear access terminal blocks and connections in the “-F” cage assemblies. alarm outputs include inverter Module Failure, overload and Transfer Switch Status. The following single phase fully equipped cages are available: M6.6- 12060-F, M9.9-12060-F and M13.2-12060-F. a dual phase split-cage system can be configured (specify M13.2-24060-F). it accommodates single and dual phase loads together.

Multi-Cage Inverter Systems

The “-S” cage assemblies, M9.9-12060-S and M13.2-12060-S, are not equipped with a transfer switch or alarm logic. They are used with a junction control panel or transfer and metering panel which combines the ac output from all cages in multi-cage systems. The system transfer, metering and alarm functions are located in these panels. Single phase systems can utilize up to 3 “-S” cage assemblies for a maximum capacity of 39.6kVa. Dual phase systems can utilize either 2 or 4 “-S” cage assemblies for a capacity of up to 52.8kVa. The l1-n-l2 output will accommodate single phase 120Vac and dual phase 240Vac loads together.

SMI 3300

DC

to

AC

Inve

rter

s

SMI 3300 Inverter System

35

DC

to A

C Inverters

TebeVerT inverter Series5 to 25kVA Inverter System

> NEBs level 3 certified to assure compatibility with the telecommunications environment

> Hot swap 5kVA inverter modules

> Hot swap static switch module

> Integrated maintenance bypass switch

> Automatic master-slave operation

> Up to five inverter modules can be paralleled as load increases

TebeVerT DSP inverter Series

60Hz Models

output capacity: 5 to 25kVA

Maximum number of Modules: 5

Input

nominal bypass ac input: 120Vac 208, 220, 240, 480Vac

number of bypass ac Phases:

1 2

bypass ac input wiring: L, N, PE L1, L2, PE

nominal Dc input: -48Vdc or 120Vdc (requires different inverter modules)

Dc input range: -15% +20%

reflected Dc ripple (48Vdc) (120Vdc):

<2mV reverse smoothing, <5% RMS

<2mV reverse smoothing, <5% RMS

Output

nominal ac output Voltage: 120Vac 120Vac

optional ac output Voltage: 120/240Vac 120/240Vac

output Voltage regulation: ±5% for all combinations of line, load and temperature

output Power Factor: 0.7 lagging to 0.8 leading

output Voltage waveform: PWM Sine wave PWM Sine wave

output crest Factor: 2.8:1 2.8:1

output Voltage Distortion: <3% @ 100% rated linear load

output overcurrent Protection: Electronic current limiting

overload rating (inverters): 200% for approx. 75 cycles (1.25 seconds)

overload rating (Static bypass): 500% for 100ms 500% for 100ms

System operating efficiency: >85% (on-line mode) / >97% (off-line mode)

Frequency Stability: ±0.1% free running, ±3% when AC present

Module capacity: 5kVA/4kW 5kVA/4kW

Static Switch Transfer Time: <2ms <2ms

60Hz Models

120, 208, 220, 240, 480Vac

output capacity: 5 to 25kVA

cooling: Temperature controlled fans

Maintenance bypass Switch:

Standard make-before-break mechanically interlocked switch provided on all models equipped with the static bypass module

remote alarming:(1) Form-C Summary Alarm, Optional Relay Card (8 Alarms), Optional SNMP

leD indicators (inverter Modules):

Output present, fault, overload, AC synchronized, parallel operation

leD indicators (Static bypass Module):

Power flow diagram, normal, fault, AC present, DC present, overload, load on bypass, load on inverter

Metering:(4) segment LCD display switchable between output voltage and current

cabinet Dimensions (in/mm): 84 x 23.6 x 23.6 / 2134 x 600 x 600

Standards

radio interference: Certified to Telecordia GR-1089

Safety listing: UL60950, UL, cUL Pending

Product certification: NEBS Level 3

Environmental

Seismic rating: NEBS Level 3, Seismic Zone 4 Optional

elevation: 1800m / 6000ft, 4000m / 1300ft at 30°C/86°F

operating Temperature: -5 to 50°C / 23 to 122°F

operating Humidity: 0 to 95% non-condensing

Module Data: 5kVA

Power rating: 5000VA / 4000W

nominal input current (-48Vdc): 98A

Max. input current (-48Vdc): 115.4A

output current (120Vac): 41.6A

TEBEVERT DSP

36

DC

to

AC

Inve

rter

s

> Hot-pluggable operation allows module addition or removal without powering down

> High power density and high efficiency (89%)

ineX System 48V Modular inverter System

Electrical

Inverter Module DC Input

nominal Voltage: 48Vdc

operating range: 40.5Vdc to 58Vdc

input Protection: Reverse Polarity Protection

Psophometric noise Voltage: <1.0mV ITU-T O.41 (16.66~6000Hz)

Inverter Module AC Output

Power rating: 1000VA / 800W, 1500VA / 1200W

waveform: Pure sine wave

Power Factor: 0.8

nominal output Voltage: 110/115/120Vac, 208/220/230/240Vac

Voltage Variation: Max ±2%

output Frequency: 50/60Hz

crest Factor: 3:1

THD:<3%, linear load<5%, non-linear load

efficiency: Min 89%

isolation ac-enclosure: Basic isolation (Pri-Gnd) 2121Vdc/1min

Dynamic response: <±10%

over load Protection:1.5*Inom >20s1.25*Inom temperature controlled

STS Module Input

over Voltage Threshold:

120Vac-Adjustablebetween127 to 138Vac, default 132Vac

220Vac-Adjustablebetween233 to 252Vac, default 242Vac

under Voltage Threshold:

120Vac-Adjustablebetween100 to 114Vac, default 108Vac

220Vac-Adjustablebetween176 to 209Vac, default 198Vac

backfeed Protection: Comply with safety requirement

redundant Power: Startup power-on by priority

Design: Source or alternative

STS Module Output

nominal output Voltage:Same as utility or the output ofInverter modules

Permissible Frequency area: Max. ±/-2.5% (inverter synchronization)

Transfer Time: Typical 1/4cycle

rated Power:50A for 110/115/120Vacand 208/220/230/240Vac

operation Methods: Inverter priority/Mains priority

Standards

ul, ce, roHS

Environmental

operating Temperature:-20 to 70°C / -4 to 158°F-5 to 58°C / 23 to 122°Fwith full performance

Storage Temperature: -40 to 85°C / -40 to 185°F

Humidity: 90% non-condensing

noise: 55dBa

Controller Module

Input

nominal Voltage: 48Vdc

operating range: 30 to 72Vdc

over current Protection: 2A Fuse

Human Interface

lcDResolution (Line X Array)4 x 16 Charactor

leD indicator3 Colored indicators for normal, warning and fault display

alarm Audio alarm when inverter, STS, controller module

System Parameter

baud rate: Setting controller com port baud rate

Keypad Tones: Setting keypad tones

Time and Date: Setting current time and date

Setting Password: Setting system password

brightness: Setting LCD brightness

Default: Change current system parameters to default value

battery calibration: Calibration battery voltage

Mechanical

Dimensions (in/mm) weight (lb/kg)

inverter Module: 10.6 x 8.5 x 1.7 / 270 x 215 x 43.8 5.5 / 2.5

STS Module: 10.6 x 8.5 x 1.7 / 270 x 215 x 43.8 4.4 / 2

controller Module: 10.9 x 3.5 x 1.7 / 277 x 88 x 43.5 2.2 / 1Hot-Swap chassis:19/23" Mouning bracketsinverter chassis

12.6 x17.3 x 1.7 / 320 x 440 x 44 5.5 / 2.5

STS and controller chassis: 12.6 x 17.3 x 1.7 / 320 x 440 x 44 7.5 / 3.4

Communication Interface

rS-232x1: Communicate with PC

rS-485x2: Communicate with supervision

Dry contactx5: Communicate with external Monitor

uSbx1: Communicate with PC

ineX inverter System48V Modular Inverter System

INEX Inverter System

37

DC

to A

C Inverters

> Versatile modular design provides flexibility for different power applications

> Expandable capacity up to 24kVA with N+1 redundancy configuration

>“Allmaster”dynamicmechanismeliminatessingle point failure to optimize reliability

INEX Inverter Module

ineX inverter System48V Modular Inverter System

ineX 48V Modular inverter System

Inverter Module

INEX inverter module provides pure sine wave AC power output for critical telecommunication equipment. Adopting N+1 redundancy design, INEX Inverter can operate up to 24 units in parallel. INEX inverter module is specially designed with compact size of maximized power density and can reach up to 5.57W/inch3 for INEX 1000 and 8.36W/inch3 for INEX1500. 1RU height designallows the module to be installed onto a standard ETSI 300mm Rack. INEX module provides the revolutionary telecom power solution in terms of maximum flexibility and reliability.

INV-4810E

Pure sine waveHot-swap replacement in shelfHigh efficiency >89%DSP design for higher system reliabilityLower audible noise <55dBASmart fan speed controlN+1 redundancy system, load sharing difference < 5%High power densityEmergency Power Off function embeddedCAN Bus interface embedded-48Vdc Telecom system applicationWide operation temperature range, -20 to 70˚C / -4 to 158˚F

STS Module

INEX STS (Static Transfer Switch) module increases system reliability by automatic power transfer between the inverter output and the AC mains. By setting up the priority of operation mode, users can change the systemstatus of “on line mode” or “off line mode”. The on line mode will keep the input power provided by inverter line and when inverter fails, the line will switch to AC utility line. In off line mode, the system power is always connected to the AC utility line and will switch to inverter power line when AC utility fails. The transfer time is less than 1/4 cycle which prevents the power interruption.The reliable performance of INEX STS module will provide the maximum protection to the connected telecommunication equipment against possible damage caused by the system power failure.

STS-050

Universal input rangeHot-swap replacement in shelfBack-feed protectionRedundant fan designRedundant power supply designOperation Priority Setup of transfer side by setting in Control ModuleFast transfer time, typically less than 1/4 cycleWide operation temperature range, -20 to 70˚C / -4 to 158˚FLower audible noise <55dBAEmergency Power Off function embeddedNo-cross connectOptional maintenance bypass switch functionCAN Bus interface embedded

Controller Module

INEX controller module allows users to monitor the system status in real time. The superior design enables users to manage the inverter and STS module status including voltage, current, frequency, capacity and temperature. With a user-friendly interface design, users can easily manage the inverter and STS module settings including voltage, frequency, redundancy (for inverter module), and priority (STS module). The controller module can also record the alarm history which can help to understand the operating status while maintaining the system or making further adjustments to improve system performance.

CAN Bus protocol for module communicationRelay contact output for customized alarmsHot-swappable designReal time clock embeddedComprehensive LCD & LED for status displayAudible alarm function

Communication Interface

The communication interface includes several options for wider applications which facilitates the remote managing to the system. The standard portsinclude relay contacts, RS-232, RS-485, USB. Relay contacts provide five programmable settings to display customized information. RS-232 & USB ports provide the serial connection to PC for software monitoring. RS-485 provides long distance connection for direct monitoring. The optional SNMP offers remote monitoring capability using a browser interface. The communication interface provides powerful monitoring and managing solutions to the system manager.

Relay contactsRS-232RS-485SNMP (Optional)USB

Telecom Power Monitoring Software

TelecomPower is a monitoring software which supports either stand alone computer or network connected computers.

Monitoring to each module in the inverter system in real timeProvides panoramic view of all the related information of utility power, system status, STS statusAuto search function with any inverter power modules in LANPassword security protectionInstall and uninstall is easy and clear

INV-4810E

38

DC

to

AC

Inve

rter

s

S4 inverter

Electrical

input Voltage: -48Vdc (40 to 60Vdc)

output Voltage:100, 110, 115, 120, 200, 220, 230, 240 (user selectable)

Output Frequency

user-Selectable: 50 or 60Hz (±0.02%)

output waveform: High resolution PWM sine wave

inverter Technology: IGBT PWM

regulation: <±1%

Static Switch

Transfer Time: <3ms

efficiency:88% typical (online mode) to 97% typical(off line eco mode)

Transient response: 5% deviation with 1ms recover from zero to full load

overload capability: 120% of continuous rated VA/W at 20˚C/68˚F

Short circuit current (Scc): 300% for more than 4 cycles

audible noise: Less than 50dBA

eMi emission: <30dBmc

Total Harmonic Distortion:<1% for linear loads, <3% for crest factor loads upto3:1

Monitoring:LCD with true RMS metering and LED status display, dry contacts, RS232

calibration: Digitally controlled/automatic

Altitude

operating Temperature:0 to 55°C / 32 to 131°F -40 to 75°C / -40 to 167°F shipping

operating Humidity: 0 to 90% relative, without non-condensing

operating altitude: <3000m / 10000ft without derating

Standards

agency approvals:UL/CSA 60950 (listed) and European Standard EN60950, CE, TUV, FCC class A certified

installation: 19", 23", 25" rack or floor mounted

Finish: RAL 902 off-white

System Height 17"W x 18.5"D*

Receiver Cabinet Capacity kVA

Inverter Capacity kVA/kW

Quantity Inverters

Power kVA/kW

DC Input (A) max

Output (A) @ 115Vac*

Approx. System Weight (lb)

Max BTU

DC Breaker (A) Suggested

AC Input Breaker (A) at 115Vac

21" 7 3.5 1 3.5/3 88 26 114 1,807 125 30

(min./max Inverter qty 1-2) 7 2 7/6 176 52 182 3,614 250 60

31.5" 14 10.5 3 10.5/9 265 78 241 5,421 375 100

(min./max Inverter qty 2-4) 14 4 14/12 353 104 299 7.227 500 125

42" 21 17.5 5 17.5/15 441 130 357 9.034 650 150

(min./max Inverter qty 3-6) 21 6 21/18 529 157 418 10.841 750 200

* Transformer will add to system weight

S4 receiver cabinet Size

Model: 7kVA 14kVA 21kVA

Dimensions (in/mm):

21 x 17 x 19 / 553.4 x 431.8 x 482.6

31 x 17 x 19 / 787.4 x 431.8 x 482.6

42 x 17 x 19 / 1066.8 x 431.8 x 482.6

Min. inverters:

1 x 3.5kVA (3.5kVA) 2 x 3.5kVA (7kVA) 3 x 3.5kVA (10.5kVA)

Max inverters:

2x3.5kVA (7kVA) 4 x 3.5kVA (14kVA) 6 x 3.5kVA (21kVA)

S4 inverter Series7 to 21kVA Inverter System

> Constructed to NEBS/Telecom industry standards

>Truemodularscalability:3.5to21kVA(3.5kVAmodules) — add modules as your system grows

> Parallel for N+1 redundancy or capacity

> Full front accessibility

> LCD status display module S4 Inverter with maintenance bypass and AC distribution

panel

S4 Inverter

39

DC

to A

C Inverters

DSP inverter Series1 to 15kVA Inverter System

> Nebs level 3 certified to assure compatibility with the telecommunications environment

> Fourth generation DSP architecture utilizing SMD for high reliability and MTBF

> Hot swap EUE static switch and inverter modules

> 6 or 15kVA EUE static switch available

DSP inverter Series

Inverter Module Rating: 1kVA 2.5kVA

nominal System output capacity with one rack Shelf: 1 to 5kVA (6kVA w/o EUE) 2.5 to 12.5kVA (15kVA w/o EUE)

nominal bypass ac input: 120Vac 120Vac

number of bypass ac Phases: 1 1

bypass ac input wiring: L, N, PE L, N, PE

bypass Voltage Tolerance: ±10%(Adjustable±5%to±15%) ±10%(Adjustable±5%to±15%)

Maximum System capacity with Two rack Shelves, without eue:

12kVA 30kVA

nominal Dc input: -48Vdc -48Vdc

Dc input range: 40.8 to 60Vdc 40.8 to 60Vdc

Output

nominal ac output Voltage: 120Vac 120Vac

output Voltage regulation: ±5% for all combinations of line, load and temperature

output Power Factor: 0.7 lagging to 0.8 leading 0.7 lagging to 0.8 leading

output Voltage waveform: DSP Sine wave DSP Sine wave

output crest Factor: 2.8:1 2.8:1

output Voltage Distortion: <3% @ 100% rated linear load <3% @ 100% rated linear load

output overcurrent Protection: Electronic current limiting Electronic current limiting

overload rating (inverters): 110% continuous, 120% for ~1 minute, 200% for ~4 seconds

overload rating (Static bypass): 500% for 100mS 500% for 100mS

optional Maintenance bypass Switch:Internally mounted, Make-before-break mechanically interlocked switch provided on all models equipped with the EUE

static bypass module

inverter Module rating: 1kVA 2.5kVA

remote alarming: (1) Form-C Inverter fault, (1) Form-C Static Switch fault

leD indicators (inverter Modules): On, Output present, DC Input OK, Inverter Fault, Parallel Operation, Overload, Bar graph for output power

Display/Metering (eue, Static bypass Module): Graphic Display (Menu Driven, password protected), Power flow diagram, LED’s (Normal, fault)

Mechanical

rack Shelf Dimensions (in/mm): 12.25 x 23 x 19.8 / 311 x 584 x 503 12.25 x 23 x 25.25 / 311 x 584 x 590

radio interference: Certified to Telecorodia GR-1089 Certified to Telecorodia GR-1089

Safety listing: UL60950 UL60950

Product certification: NEBS Level 3, Seismic Zone 4 NEBS Level 3, Seismic Zone 4

elevation: <3000m / 10000ft without derating <3000m / 10000ft without derating

operating Temperature: 0 to 55°C / 32 to 131°F 0 to 55°C / 32 to 131°F

operating Humidity: 0 to 95% non-condensing 0 to 95% non-condensing

Power rating: 1000VA / 800W 2500VA / 2000W

nominal input current (-48Vdc): 19A 47A

Maximum input current: 22.5A 55A

output current (120Vac): 8.33A 20.83A

weight (lb/kg): 11 / 5 17.6 / 8

DSP inverter

40

DC

to

AC

Inve

rter

s

S5 inverter Series1500W Inverter System

> Ultra, compact 1RU module, 19" rackmountable

> Paralleable output with current share and synchronization of multiple inverters working in parallel (N+1)

> Split phase output (120/240Vac)

S5 inverter

Input Characteristics

input Voltage range: 40A to 72Vdc (48Vdc); 20A to 36Vdc (24Vdc)

input current: 48A at 36Vdc (48Vdc); 100A at 18Vdc (24Vdc)

inrush current: ETSI EN 300 132-2 V2.1.2 clause 4.7

input over current Protection:

Internal fuse, 70A (48Vdc), Internal fuse, 140A (24Vdc)

input over Voltage Protection: 74V (48Vdc); 37V (24Vdc)

input under Voltage Protection: 36V (48Vdc); 18V (24Vdc)

Output Characteristics

output Power: 1500W

output Voltage range:230Vacmodels:200to240Vac 115Vacmodels:110to120Vac

Frequency: 50 or 60Hz

overload:230Vacmodels:1800VA 115Vacmodels:1650VA

Surge:230Vacmodels:2300VAfor200ms 115Vacmodels:1650VAfor200ms

efficiency: up to 93%

load Power Factor: 0.33 lagging or leading

load crest Factor: 4

regulation load: -3 to 1% over full operating range

regulation line: ±0.1% over full operating range

output noise and ripple: 2% Vp-p (20Hz/20MHz)

Distortion: <2% on resistive load

over Voltage Protection: All outputs set at 115% ±2% of nominal

under Voltage Protection: All outputs set at 85% ±2% of nominal

over current Protection: 230Vacmodels:1to8Aselectable 115Vacmodels:2to15Aselectable

Safety Over Current Protection

by Safety circuit breaker: 230Vacmodels:10A,115Vacmodels:15A

Short-circuit Protection: 230Vacmodels:30A,115Vacmodels:60A

over Temperature Protection:

at Tamb >65˚C / 149˚F and Tint>100˚C / 212˚F (visual and acoustic indication 5˚C / 41˚F before shutdown)

Protection restore Modes:The restore mode of each protection can be individuallyselectedto“latch”or“autorestart”

Signal and Controls

lcD Panel: 2 line LCD panel with keypad for menu navigation

leD indicator:4:Green(powerON),Red(genericfault,OT,fanfail), Input OV, UV, OC Output OV, V, OC

general alarm Signal: By a photo-relay (open if in fault mode)

communications: RS-485 or CANBUS communications interface

Environmental

operating Temperature range: -25 to 55˚C / -13 to 131˚F

operating Humidity: 0 to 90% non-condensing

Storage: -40 to 85˚C / -40 to 185˚F

MTbF: >250000hrs at 40˚C / 104˚F

Altitude

operating: 3963m / 13000ft

non operating: 12192m / 40000ft

Output Voltage

Power Derating @ 75w/˚c: 55 to 65˚C / 131 to 149˚F

Temperature coefficient: 0.02% per C˚ within rated load

Safety agency compliance: cCSAus, Kema, CB report, CE mark

Isolations

Pri-Sec: 3000Vrms

Sec-gnD: 1500Vrms

Pri-gnD: 1000Vrms

Signal-gnD: 0Vrms

Mechanical Specifications

Dimensions (in/mm): 19 x 1.71 x 14.94 / 482.6 x 43.5 x 379.5

weight (lb/kg): 12.34 / 5.6

Warranty

2 years from date of shipment, standard product only

DC in AC out

Sync

DC

AC

DC

AC

DC

AC

S5 1500W Inverter

41

DC

to A

C Inverters

MS Power inverter Series1 and 2kVA Inverter System

> Standard 19"/23", 2RU rackmount

> 1kVA/800W and 2kVA/1600W

> Pure sine wave output

> Utility bypass function

> UL/cUL approved

> RS-232 communication

>Internal“overtemperature”protection

> Input reverse polarity protection

> Output overload protection

Majorsine Power inverter

Models Majorsine1000-24-2U Majorsine1000-48-2U Majorsine2000-48-2U

DC Input

Voltage: 20 to 30Vdc 40 to 60Vdc 40 to 60Vdc

rated current: 50A 25A 50A

Protection: Fuse and DC Breaker Fuse and DC Breaker Fuse and DC Breaker

efficiency: >85% (full linear load), 24Vdc I/P, 120Vac O/P

Output (Backup)

capacity: 1kVA / 800W 1kVA / 800W 2kVA / 1600W

Voltage: 110, 115, 120, 125Vac 110, 115, 120, 125Vac 110, 115, 120, 125Vac

Voltage regulation: ±2% ±2% ±2%

Frequency: 50/60Hz ±0.2Hz 50/60Hz ±0.2Hz 50/60Hz ±0.2Hz

waveform: Pure sine wave Pure sine wave Pure sine wave

THD (linear load): 3% 120V/100% 3% 120V/100% 3% 120V/100%

THD (SPS load): 5% 120V/100% 5% 120V/100% 5% 120V/100%

crest Factor: 3:1 3:1 3:1

receptacles: (4) NEMA 5-15R outlets (4) NEMA 5-15R outlets (4) NEMA 5-20R outlets

Utility Power (Bypass)

Voltage (nominal): 120Vac 120Vac 120Vac

Frequency: 60 ±5Hz 60 ±5Hz 60 ±5Hz

Protection: AC Circuit Breaker AC Circuit Breaker AC Circuit Breaker

Interface

communication: RS232 / Dry-contact RS232 / Dry-contact RS232 / Dry-Contact

leD Display: Inverter ON, Overload, DC Abnormal Inverter ON, Overload, DC Abnormal Inverter ON, Overload, DC Abnormal

lcD Display:Inverter ON, Output Voltage and Frequency, Input Voltage, Load Percentage, DC Voltage, System Model, Internal Environment Temp., Utility

status, Short circuit, Over Temp.

Protection

Short: For 1 second; Switch to Bypass, then shutdown

overload: 105 to 125% for 3 minutes; 126 to 150% for 3 seconds; >150% for 1 second; Switch to bypass

Temperature: 55˚ ±5˚C (Inside the case) 131˚ ±41˚F 55˚ ±5˚C (Inside the case) 131˚ ±41˚F 55˚ ±5˚C (Inside the case) 131˚ ±41˚F

Environment

operating Temperature: 0 to 50˚C / 32 to 122˚F 0 to 50˚C / 32 to 122˚F 0 to 50˚C / 32 to 122˚F

Storage Temperature: -20 to 70˚C / -4 to 158˚F -20 to 70˚C / -4 to 158˚F -20 to 70˚C / -4 to 158˚F

Humidity: 0 to 90˚C / 32 to 194˚F non-condensing 0 to 90˚C / 32 to 194˚F non-condensing 0 to 90˚C / 32 to 194˚F non-condensing

acoustic noise: 46dBA @ 1 M 46dBA @ 1 M 46dBA @ 1 M

Safety: UL / cUL UL / cUL UL / cUL

eMi / rFi: FCC Class A FCC Class A FCC Class A

Mechanical

Dimensions (in/mm): 17.32 x 11.81 x 3.46 / 440 x 300 x 88, 2RU

weight (lb/kg): 17.6 / 8 15.4 / 7 15.4 / 7

MS Power Inverter

42

DC

to A

C Inverters

43

NetBotz® Monitoring

> Improve response time to incident via troubleshooting, early detection and automated threat response

> Reduce staffing requirements by augmenting with remote eyes and ears

> Reduce operating costs with early problem detection

> Reduce operating costs through fewer service calls

> Improve business decision support via trend monitoring

> Improve customer service through increased system and information availability

The NetBotz system includes a base station appliance, environmental sensors, color camera and

integrated software that assess the severity of threats and provides notification. The Centralized

Management console is a central station platform that can communicate with, configure, manage,

archive and provide trend analysis on data coming from as many as 500 NetBotz appliances

throughout a distributed enterprise. Users receive alarms and notification via e-mail, phone or

pager, and in the form of text messages or video clips. NetBotz is the only product available today

that leverages your current IT infrastructure and the power of the Web. Our award-winning,

patented IP-based technology means no custom install, no hassles and no extra expense. The

solution integrates fully with industry-leading network monitoring systems.

Top Three risk Factors for your network

> EnvironmentalThe #1 cause of downtime for remote locations, environmental problems go beyond worries of

fires and floods. Cooling and power are key points of exposure that become more important as

equipment density increases.

> Human ErrorWecallthisthe“unspokenepidemic”becausenoonelikestodiscusshumanerrorandthe

tremendous impact it can have on availability. But the fact is, it’s the second greatest cause of

downtimeinremoteorunsupervisedlocationsbecausesystemsareoftenhousedinjanitorclosets,

wiring closets or other less than optimal settings.

> Physical TheftAs assets become smaller and more efficient with hot swappable drives, they become more attractive

targets that are easier to steal. Physical attacks against digital assets are often overlooked and are a

source of real concern.

NetB

otz M

on

itorin

g

44

AC

UP

S

45

Sin

gle an

d T

hree P

hase U

PS

Single and Three Phase UPS> SmartUPS® XL

The SmartUPS XL protects your data by supplying reliable, network-grade power and scalable runtime in tower or rackmount form. Typical applications requiring longer runtime include critical application servers and storage, IP and PBX based voice networks, and enterprise network switches and hubs. The SmartUPS XL adds the advantage of unsurpassed runtime capability for those business applications that demand continual uptime.

> SmartUPS RTThe SmartUPS RT is a family of high-density, performance UPSs for voice and data networks, medical labs and light industrial applications. Capable of supporting 10kVA in a 6RU rack/tower convertible form, users can support power hungry blade servers or heavily loaded equipment racks. Customers with harsh power environments looking for extremely tight voltage and frequency regulation, internal bypass and input power factor correction typical of double conversion online topology will get them in the SmartUPS RT.

> Symmetra®

Engineered to deliver the highest level of business continuity possible, Symmetra uses a modular, redundant architecture that can scale power and runtime as demand increases or when higher levels of availability are required. Typical applications include Web and other key application servers, IP based and traditional PBX voice solutions, and enterprise type network switches.

> Symmetra LXWith built-in network manageability, rack-optimization and tower models available from 4 to 16kVA N+1 redundant, the online Symmetra LX is the ideal choice to protect high-performance IT and Telecom equipment in business-critical server and network rooms. A flexible rack/stack design offers unmatched runtime and power capacity in space-constrained environments.

> 1600EP SeriesAlpha’s 1600EP Series incorporates dual conversion technology that provides power conditioning for sensitive headend electronics, regardless of the quality of utility or generator input power. This topology has power factor correction on the input circuit that provides compatibility with all generators, even when the UPS is sized near generator capacity.

> Triniti™ 4200 SeriesThe Alpha Triniti Series three phase UPS incorporates dual conversion technology designed to provide power conditioning for sensitive headend electronics, regardless of the quality of the utility or generator input power. Its unique active front end design provides power factor correction. In addition to providing utility cost savings, this feature provides compatibility with most existing headend generators, including those with mechanical governors running at near capacity.

> GalaxyThe Galaxy Series is the world’s first data-center grade UPS designed specifically for mid-range enterprise level applications. The AlphaSource Galaxy delivers the optimum level of reliability, availability and scalability demanded by the new generation of critical enterprise applications.

> Symmetra PXThe Symmetra PX is a world class, redundant and scalable power protection system. Seamlessly integrating into today’s state-of-the-art data center designs, the Symmetra PX is a true modular system. Made up of dedicated and redundant modules-power, intelligence, battery and bypass, this architecture can scale power and runtime as demand grows or as higher levels of availability are required.

> EPS 7000The EPS 7000 has unparalleled reliability and performance with time tested architecture and one of the smallest footprints in the industry. Engineered with high output power, fault tolerant architecture and redundant paralleling logic, the robust EPS 7000 incorporates the best innovative technology in the three phase UPS marketplace.

46

Sin

gle

Ph

ase

UP

S

SmartuPS Xl

Models: Smart-UPS 750T Smart-UPS 1000T Smart-UPS 1400RM Smart-UPS 1500RMT Smart-UPS 2200RM Smart-UPS 2200RMT

configuration: Tower Tower Rackmount Rackmount/Tower Rackmount Rackmount/Tower

Output

output Power capacity: 750VA / 600W 1000VA / 800W 1400VA / 1050W 1440VA / 1425W 1850VA / 1850W 1850VA / 1850W

Max configurable Power: 750VA / 600W 1000VA / 800W 1400VA / 1050W 1440VA / 1425W 2200VA / 1980W 2200VA / 1980W

nominal output Voltage: 120V 120V 120V 120V 120V 120V

waveform Type: Sine wave Sine wave Sine wave Sine wave Sine wave Sine wave

output connections: (8) NEMA 5-15R (8) NEMA 5-15R (6) NEMA 5-15R (8) NEMA 5-15R (9) NEMA 5-15R, (2) NEMA 5-20R

Input

nominal input Voltage: 120V 120V 120V 120V 120V 120V

input Frequency (auto sensing): 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz

input connections: NEMA 5-15P NEMA 5-15P NEMA 5-15P NEMA 5-15P NEMA 5-20P NEMA 5-20P

cord length: 1.8m / 5.9ft 1.8m / 5.9ft 1.8m / 5.9ft 3.1m / 10.2ft 2.4m / 7.9ft 2.4m / 7.9ft

bypass: - - - - - -

Batteries and Runtime

battery Type: Maintenance-free sealed Lead-Acid, leakproof VRLA Maintenance-free sealed Lead-Acid, leakproof

Typical recharge Time (hrs): 3 2 3 3 3 3

replacement battery cartridge: RBC7 RBC7 RBC25 RBC43 RBC105 RBC55

rbc™ Quantity: 1 1 1 1 1 1

runtime Full / Half load (min): 16.6 / 50.6 9.6 / 33.3 6.6 / 23.5 11.9 / 28.3 8.2 / 29.4 7.4 / 27.1

Communication and Management

interface Port(s): DB-9, RS-232, SmartSlot, USB DB-9, RS-232DB-9, RS-232, RJ-45 10/100 Base-T, USB

DB-9, RS-232, SmartSlot, USB

SmartSlot™ interface Qty: 1 1 1Network Mgmt Card w/ Environmental Monitoring

1 1

control Panel: LED status display with load and battery bar-graphs and On Line, On Battery, Replace Battery, and Overload Indicators

audible alarm: Alarm when on battery, low battery alarm

Mechanical

Dimensions (in/mm):8.5 x 6.7 x 17.3 / 216 x 170 x 439

8.5 x 6.7 x 17.3 / 216 x 170 x 439

5.1 x 17 x 15.5 / 130 x 431.8 x 394

3.4 x 17 x 26.7 / 86.4 x 431.8 x 678.2

5.2 x 19 x 26 / 133 x 483 x 660

17 x 7.7 x 19.8 / 431.8 x 196 x 503

rack Height: - - 3RU 2RU 3RU 5RU

net weight (lb/kg): 53 / 24 60 / 27.2 70 / 31.8 103 / 46.7 124 / 56.2 121 / 54.9

Environmental

Temperature: 0 to 40˚C / 32 to 104˚F

Humidity: 0 to 95% 0 to 95% 0 to 85% 0 to 95% 0 to 95% 0 to 95%

elevation: 0 to 1524m / 0 to 5000ft 0 to 3000m / 0 to 10000ft

Storage Temperature: -15 to 56.1˚C / 5 to 133˚F -5 to 55˚C / 23 to 131˚F -15 to 56.1˚C / 5 to 133˚F

audible noise at 1 Meter: 42dBA 42dBA 48dBA 55dBA 53dBA 53dBA

online Thermal Dissipation: 100BTU/hr 120BTU/hr 155BTU/hr 300BTU/hr 375BTU/hr 305BTU/hr

Conformance

regulatory approvals: BSMI, CSA, FCC Part 15 Class A, UL 1778 BSMI, CSA, UL 1778BSMI, CSA, FCC Part 15 Class A, UL 1778, NOM, VCCI

CSA, FCC Part 15 Class A, UL 1778, UL 1449

CSA, FCC Part 15 Class A, UL 1778

reference: SUA750XL SUA1000XL SU1400RMXLB3U SU1500RMXL2U SUA2200RMXL3U SUA2200XL

Options:extendedbatteryruntimes,interfacecables,NetBotz® accessories and sensors, SmartSlot expansion chassis, UPS dry-contact management, UPS environmental monitoring card, UPS interface expanders, UPS network management cards, UPS out-of-band management, rack enclosures and accessories, NetShelter 2 post open frame racks, NetShelter 4 post open frame racks, NetShelter SX enclosures, NetShelter VX enclosures, rack fan tray, basic rack PDU, metered rack PDU, power cords, rack automatic transfer switch, switched rack PDU, replacement batteries, extended warranty, installation services, on site service, remote monitoring service, StruXure manager, powerchute business edition, and UPS remote power off interface

SmartuPS® XlSingle Phase UPS

> Scalable runtime

> Boost and trim Automatic Voltage Regulation (AVR)

> Temperature-compensated battery charging

> Automatic restart of loads after UPS shutdown

> Standard 2 year warrantySUA1000XL

47

Sin

gle P

hase U

PS

SmartuPS® XlSingle Phase UPS

> Hot-swappable batteries

>Adjustablevoltage-transferpoints

> LED status indicators

> Generator compatible

SUA1000XL

SmartuPS Xl

Models:Smart-UPS 2200 RMT208

Smart-UPS 3000 RMTSmart-UPS 3000 RMT208

Smart-UPS 3000 RMTMOD

Smart-UPS 3000 RM

configuration: Rackmount Rackmount/Tower Rackmount/Tower Rackmount/Tower Rackmount

Output

output Power capacity: 2200VA / 1600W 3000VA / 2700W 3000VA / 2700W 3000VA / 2850W 2700VA / 3000W

Max configurable Power: 2200VA / 1600W 3000VA / 2700W 3000VA / 2700W 3000VA / 2850W 2700VA / 3000W

nominal output Voltage: 208V 120V 208V 120V 120Vwaveform Type: Sine wave Sine wave Sine wave Sine wave Sine wave

output connections:(2) NEMA 5-15R, (1) NEMA L6-20R, (2) NEMA L6-30R

(9) NEMA 5-15R, (2) NEMA 5-20R

(2) NEMA L6-20R, (2) NEMA L6-30R

(6) NEMA 5-15R, (2) NEMA 5-20R

(9) NEMA 5-15R, (2) NEMA 5-20R

Input

nominal input Voltage: 208V 120V 208V 120V 120V

input Frequency (auto sensing): 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz

input connections: NEMA L6-20P NEMA L5-30P NEMA L6-20P NEMA L5-30P NEMA L5-30P

cord length: 2m / 6.6ft 2.4m / 7.9ft 2m / 6.6ft 3.1m / 10.2ft 2.4m / 7.9ft

bypass: - - - Internal Bypass (Auto/man) -

Batteries and Runtime

battery Type: Maintenance-free sealed Lead-Acid, leakproof VRLAMaintenance-free sealed

Lead-Acid, leakproof

Typical recharge Time (hrs): 3 3 3 3 3replacement battery cartridge: RBC11 RBC55 RBC55 RBC43 APCRBC105rbc™ Quantity: 1 1 1 1 1runtime Full / Half load (min): 9.7 / 34.3 5.5 / 13.6 5.5 / 13.5 3.5 / 11.9 5.4 / 15

Communication and Management

interface Port(s):DB-9, RS-232, SmartSlot

DB-9, RS-232, SmartSlot

DB-9, RS-232, SmartSlot

DB-9, RS-232, RJ-45 10/100 Base-T, USB

DB-9, RS-232, SmartSlot

SmartSlot™ interface Qty: 1 1 1Network Mgmt Card w/ Environmental Monitoring

1

control Panel: LED status display with load and battery bar-graphs and On Line, On Battery, Replace Battery, and Overload Indicators

audible alarm: Alarm when on battery, low battery alarm

Mechanical

Dimensions (in/mm):8.8 x 19 x 17.8 / 223.5 x 482.6 x 452.1

17 x 7.7 x 19.8 / 431.8 x 196 x 503

17 x 7.7 x 19.8 / 431.8 x 196 x 503

3.4 x 17 x 26.7 / 86.4 x 431.8 x 678.2

5.3 x 19 x 26 / 134.6 x 482.6 x 660.4

rack Height: 5RU 5RU 5RU 2RU 3RU

net weight (lb/kg): 132 / 59.9 121 / 54.9 121 / 54.9 103 / 46.7 124 / 56.2

Environmental

Temperature: 0 to 40˚C / 32 to 104˚F

Humidity: 0 to 95% 0 to 95% 0 to 95% 0 to 95% 0 to 95%

elevation: 0 to 3000m / 0 to 10000ftStorage Temperature: -15 to 56.1˚C / 5 to 133˚F -5 to 55˚C / 23 to 131˚F -15 to 56.1˚C / 5 to 133˚F

audible noise at 1 Meter: 53dBA 53dBA 53dBA 55dBA 53dBA

online Thermal Dissipation: 305BTU/hr 305BTU/hr 275BTU/hr 300BTU/hr 375BTU/hr

Conformance

regulatory approvals: CSA, FCC Part 15 Class A, UL 1778BSMI, CSA, FCC Part 15 Class A, UL 1778, NOM, VCCI

CSA, FCC Part 15 Class A, UL 1778, UL 1449

reference: SU2200RMXLTNET SUA3000XL SUA3000XLT SUM3000RMXL2U SUA3000RMXL3U

Options:extendedbatteryruntimes,interfacecables,NetBotz® accessories and sensors, SmartSlot expansion chassis, UPS dry-contact management, UPS environmental monitoring card, UPS interface expanders, UPS network management cards, UPS out-of-band management, rack enclosures and accessories, NetShelter 2 post open frame racks, NetShelter 4 post open frame racks, NetShelter SX enclosures, NetShelter VX enclosures, rack fan tray, basic rack PDU, metered rack PDU, power cords, rack automatic transfer switch, switched rack PDU, replacement batteries, extended warranty, installation services, on site service, remote monitoring service, StruXure manager, powerchute business edition, and UPS remote power off interface

48

Sin

gle

Ph

ase

UP

S

SmartuPS® rTSingle Phase UPS

> Automatic internal bypass

> Intelligent battery management

> Hot-swappable batteries

> Standard 2 year warranty

SURTA2000XL

SmartuPS rT

Models:Smart-UPS RT 1500T Smart-UPS RT 1500RM

Smart-UPS RT 2000T Smart-UPS RT 2000RM

Smart-UPS RT 3000T Smart-UPS RT 3000RM

Smart-UPS RT 3000T208 Smart-UPS RT 3000RM208

configuration: Rackmount/Tower Rackmount/Tower Rackmount/Tower Rackmount/Tower

Output

output Power capacity: 1500VA / 1050W 2000VA / 1400W 3000VA / 2100W 3000VA / 2100W

Max configurable Power: 1500VA / 1050W 2000VA / 1400W 3000VA / 2100W 3000VA / 2100W

nominal output Voltage: 120V 120V 120V 208V or 240V

waveform Type: Sine wave Sine wave Sine wave Sine wave

output connections: (6) NEMA 5-15R (6) NEMA 5-15R (6) NEMA 5-15R, (2) NEMA 5-20R (2) NEMA L6-20R, (2) NEMA L6-30R

Input

nominal input Voltage: 120V 120V 120V 208V

input Frequency (auto sensing): 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz

input connections: NEMA 5-15P NEMA 5-20P NEMA L5-30P NEMA L6-30P

cord length: 1.8m / 5.9ft 1.8m / 5.9ft 3.1m / 10.2ft 3.1m / 10.2ft

bypass: Built-in Bypass Built-in Bypass Internal Bypass (Automatic and Manual)

Batteries and Runtime

battery Type: Maintenance-free sealed Lead-Acid, leakproof

Typical recharge Time (hrs): 3 3 2.5 2.5

replacement battery cartridge: RBC57 RBC57 RBC44 RBC44

rbc™ Quantity: 1 1 1 1

runtime Full / Half load (min): 8.6 / 22.2 5 / 15.2 14.1 / 33.9 14.1 / 33.9

Communication and Management

interface Port(s): DB-9, RS-232, SmartSlot, USB

SmartSlot™ interface Qty: 1 1 1 1

control Panel: LED status display with load and battery bar-graphs and On Line, On Battery, Replace Battery, Overload and Bypass Indicators

audible alarm: Alarm when on battery, low battery alarm, overload alarm

emergency Power off (ePo): Yes Yes Yes Yes

Mechanical

Dimensions - rackmount (in/mm): 3.4 x 17 x 22 / 86.4 x 431.8 x 558.8 5.1 x 17 x 26 / 129.5 x 431.8 x 660.4

rack Height: 2RU 2RU 3RU 3RU

net weight (lb/kg): 53 / 24 60 / 27.2 70 / 31.8 103 / 46.7

Environmental

Temperature: 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F

Humidity: 0 to 95% 0 to 95% 0 to 95% 0 to 95%

elevation: 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft

Storage Temperature: -20 to 50˚C / -4 to 122˚F -20 to 50˚C / -4 to 122˚F -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F

audible noise at 1 Meter: 45dBA 45dBA 55dBA 55dBA

online Thermal Dissipation: 393BTU/hr 700BTU/hr 655BTU/hr 655BTU/hr

Conformance

regulatory approvals: BSMI, CSA, FCC Part 15 Class A, UL 1778 CSA, FCC Part 15 Class A, UL 1778

reference: SURTA1500RMXL, SURTA1500XL SURTA2000RMXL, SURTA2000XL SURTA3000RMXL, SURTA3000XL SURTD3000RMXLT, SURTD3000XLT

Options:extendedbatteryruntimes,interfacecables,NetBotz® accessories and sensors, SmartSlot expansion chassis, UPS dry-contact management, UPS environmental monitoring card, UPS interface expanders, UPS network management cards, UPS out-of-band management, rack enclosures and accessories, NetShelter 2 post open frame racks, NetShelter 4 post open frame racks, NetShelter SX enclosures, NetShelter VX enclosures, rack fan tray, basic rack PDU, metered rack PDU, power cords, rack automatic transfer switch, switched rack PDU, replacement batteries, extended warranty, installation services, on site service, remote monitoring service, StruXure manager, powerchute business edition, and UPS remote power off interface

49

Sin

gle P

hase U

PS

SmartuPS® rTSingle Phase UPS

> Automatic restart of loads after UPS shutdown

> Temperature-compensated battery charging

> LED Status IndicatorsSURT6000RMXLT

SmartuPS rT

Models:Smart-UPS RT 3000T208/120 Smart-UPS RT 3000RM208/120

Smart-UPS RT 5000T Smart-UPS RT 5000RM

Smart-UPS RT 5000T208/120 Smart-UPS RT 5000RM208/120

configuration: Rackmount/Tower Rackmount/Tower Rackmount/Tower

Output

output Power capacity: 3000VA / 2100W 5000VA / 3500W 5000VA / 3500W

Max configurable Power: 3000VA / 2100W 5000VA / 3500W 5000VA / 3500W

nominal output Voltage: 120 / 280, 240V 208V or 240V 120 / 280, 240V

waveform Type: Sine wave Sine wave Sine wave

output connections:(12) NEMA 5-20R, (2) NEMA L6-20R, (1) NEMA 5-20R

(2) NEMA L6-20R, (2) NEMA L6-30R(12) NEMA 5-20R, (2) NEMA L6-20R, (1) NEMA 5-20R

Input

nominal input Voltage: 208V 208V 208V

input Frequency (auto sensing): 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz

input connections: NEMA L6-30P NEMA L6-30P NEMA L6-30P

cord length: 3.1m / 10.2ft 3.1m / 10.2ft 3.1m / 10.2ft

bypass: Internal Bypass (Automatic and Manual)

Batteries and Runtime

battery Type: Maintenance-free sealed Lead-Acid, leakproof

Typical recharge Time (hrs): 2.5 2.5 2.5

replacement battery cartridge: RBC44 RBC44 RBC44

rbc™ Quantity: 1 1 1

runtime Full / Half load (min): 14.4 / 33.9 5 / 15.4 5 / 15.4

Communication and Management

interface Port(s): DB-9, RS-232, SmartSlot, USB

SmartSlot™ interface Qty: 1 UPS Network Management Card w/ Environmental Monitoring

control Panel: LED status display with load and battery bar-graphs and On Line, On Battery, Replace Battery, Overload and Bypass Indicators

audible alarm: Alarm when on battery, low battery alarm, overload alarm

emergency Power off (ePo): Yes Yes Yes

Mechanical

Dimensions - rackmount (in/mm): 8.6 x 19 x 26 / 218.4 x 482.6 x 660.4 5.1 x 17 x 26 / 129.5 x 431.8 x 660.4 8.6 x 17 x 26 / 218.4 x 431.8 x 660.4

rack Height: 5RU 3RU 5RU

net weight (lb/kg): 221 / 100.2 120 / 54.4 221 / 100.2

Environmental

Temperature: 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F

Humidity: 0 to 95% 0 to 95% 0 to 95%

elevation: 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft

Storage Temperature: -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F

audible noise at 1 Meter: 55dBA 55dBA 55dBA

online Thermal Dissipation: 655BTU/hr 1040BTU/hr 1040BTU/hr

Conformance

regulatory approvals: CSA, FCC Part 15 Class A, UL 1778 CSA, FCC Part 15 Class A, UL 1778 CSA, FCC Part 15 Class A, UL 1778

reference: SURTD3000RMXLT-1TF5, SURTD3000XLT-1TF5 SURTD5000RMXLT, SURTD5000XLT-1TF5 SURTD5000RMXLT-1TF5, SURTD5000XLT-1TF5

Options:extendedbatteryruntimes,interfacecables,NetBotz® accessories and sensors, SmartSlot expansion chassis, UPS dry-contact management, UPS environmental monitoring card, UPS interface expanders, UPS network management cards, UPS out-of-band management, rack enclosures and accessories, NetShelter 2 post open frame racks, NetShelter 4 post open frame racks, NetShelter SX enclosures, NetShelter VX enclosures, rack fan tray, basic rack PDU, metered rack PDU, power cords, rack automatic transfer switch, switched rack PDU, replacement batteries, extended warranty, installation services, on site service, remote monitoring service, StruXure manager, powerchute business edition, and UPS remote power off interface

50

Sin

gle

Ph

ase

UP

S

SmartuPS® rTSingle Phase UPS

> Flash-upgradeable firmware

> Frequency and voltage regulation

> Input power factor protectionSURT8000RMXLT

SmartuPS rT

Models:Smart-UPS RT 6000T Smart-UPS RT 6000RM

Smart-UPS RT 6000T208/120 Smart-UPS RT 6000RM208/120

Smart-UPS RT 8000T Smart-UPS RT 8000RM

configuration: Rackmount/Tower Rackmount/Tower Rackmount/Tower

Output

output Power capacity: 6000VA / 4200W 6000VA / 4200W 8000VA / 6400W

Max configurable Power: 6000VA / 4200W 6000VA / 4200W 8000VA / 6400W

nominal output Voltage: 208V or 240V 120 / 280, 240V 208V or 240V

waveform Type: Sine wave Sine wave Sine wave

output connections: (2) NEMA L6-20R, (2) NEMA L6-30R(12) NEMA 5-20R, (2) NEMA L6-20R, (1) NEMA L6-30R

(1) Hard Wire 3-wire, (2) NEMA L6-20R, (2) NEMA L6-30R

Input

nominal input Voltage: 208V 208V 208V

input Frequency (auto sensing): 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz

input connections: NEMA L6-30P NEMA L6-30P Hard Wire 3-wire

cord length: 3.1m / 10.2ft 3.1m / 10.2ft 3.1m / 10.2ft

bypass: Internal Bypass (Automatic and Manual)

Batteries and Runtime

battery Type: Maintenance-free sealed Lead-Acid, leakproof

Typical recharge Time (hrs): 2.5 2.5 2.5

replacement battery cartridge: RBC44 RBC44 RBC44

rbc™ Quantity: 1 1 2

runtime Full / Half load (min): 5.3 / 15.8 5.3 / 15.8 6.3 / 17.9

Communication and Management

interface Port(s): DB-9, RS-232, SmartSlot, USB DB-9, RS-232, RJ-45 10/100 Base-T, SmartSlot

SmartSlot™ interface Qty: UPS Network Management Card w/ Environmental Monitoring

control Panel: LED status display with load and battery bar-graphs and On Line, On Battery, Replace Battery, Overload and Bypass Indicators

audible alarm: Alarm when on battery, low battery alarm, overload alarm

emergency Power off (ePo): Yes Yes Yes

Mechanical

Dimensions - rackmount (in/mm): 5.1 x 17 x 26 / 129.5 x 431.8 x 660.4 8.6 x 17 x 26 / 218.4 x 431.8 x 660.4 10.4 x 17 x 26.1 / 264.2 x 431.8 x 663.4

rack Height: 3RU 5RU 6RU

net weight (lb/kg): 120 / 54.4 221 / 100.2 244 / 110.7

Environmental

Temperature: 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F

Humidity: 0 to 95% 0 to 95% 0 to 95%

elevation: 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft

Storage Temperature: -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F

audible noise at 1 Meter: 55dBA 55dBA 55dBA

online Thermal Dissipation: 1040BTU/hr 1040BTU/hr 1535BTU/hr

Conformance

regulatory approvals: CSA, FCC Part 15 Class A, UL 1778

reference: SURT6000RMXLT, SURT6000XLT SURT6000RMXLT-1TF5, SURT6000XLT-1TF5 SURT8000RMXLT, SURT8000XLT

Options:extendedbatteryruntimes,interfacecables,NetBotz® accessories and sensors, SmartSlot expansion chassis, UPS dry-contact management, UPS environmental monitoring card, UPS interface expanders, UPS network management cards, UPS out-of-band management, rack enclosures and accessories, NetShelter 2 post open frame racks, NetShelter 4 post open frame racks, NetShelter SX enclosures, NetShelter VX enclosures, rack fan tray, basic rack PDU, metered rack PDU, power cords, rack automatic transfer switch, switched rack PDU, replacement batteries, extended warranty, installation services, on site service, remote monitoring service, StruXure manager, powerchute business edition, and UPS remote power off interface

51

Sin

gle P

hase U

PS

SmartuPS® rTSingle Phase UPS

> Generator compatible

> Cold-start capable

> Resettable circuit breakers SURT8000XLT

SmartuPS rT

Models:Smart-UPS RT 8000T208/120 Smart-UPS RT 8000RM208/120

Smart-UPS RT 1000T Smart-UPS RT 1000RM

Smart-UPS RT 1000T208/120 Smart-UPS RT 1000RM208/120

configuration: Rackmount/Tower Rackmount/Tower Rackmount/Tower

Output

output Power capacity: 8000VA / 6400W 10000VA / 8000W 10000VA / 8000W

Max configurable Power: 8000VA / 6400W 10000VA / 8000W 10000VA / 8000W

nominal output Voltage: 120 / 280, 240V 208V or 240V 120 / 280, 240V

waveform Type: Sine wave Sine wave Sine wave

output connections:(1) Hard Wire 3-wire, (12) NEMA 5-20R, (2) NEMA L6-20R, (1) NEMA L6-30R

(1) Hard Wire 3-wire, (2) NEMA L6-20R, (1) NEMA L6-30R

(24) NEMA 5-20R, (2) NEMA L6-20R

Input

nominal input Voltage: 208V 208V 208V

input Frequency (auto sensing): 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz

input connections: Hard Wire 3-wire Hard Wire 3-wire Hard Wire 3-wire

cord length: 3.1m / 10.2ft 3.1m / 10.2ft 3.1m / 10.2ft

bypass: Internal Bypass (Automatic and Manual)

Batteries and Runtime

battery Type: Maintenance-free sealed Lead-Acid, leakproof

Typical recharge Time (hrs): 2.2 2.2 2.2

replacement battery cartridge: RBC44 RBC44 RBC44

rbc™ Quantity: 2 2 2

runtime Full / Half load (min): 6.3 / 17.9 4 / 13.2 4 / 13.2

Communication and Management

interface Port(s): DB-9, RS-232, RJ-45 10/100 Base-T, SmartSlot

SmartSlot™ interface Qty: UPS Network Management Card w/ Environmental Monitoring

control Panel: LED status display with load and battery bar-graphs and On Line, On Battery, Replace Battery, Overload and Bypass Indicators

audible alarm: Alarm when on battery, low battery alarm, overload alarm

emergency Power off (ePo): Yes Yes Yes

Mechanical

Dimensions - rackmount (in/mm): 13.9 x 17 x 26 / 353.1 x 431.8 x 663.4 10.4 x 17 x 26.1 / 264.2 x 431.8 x 663.4 17.4 x 17 x 26.1 / 442 x 431.8 x 663.4

rack Height: 8RU 6RU 10RU

net weight (lb/kg): 345 / 156.5 224 / 110.7 440 / 199.6

Environmental

Temperature: 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F

Humidity: 0 to 95% 0 to 95% 0 to 95%

elevation: 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft

Storage Temperature: -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F

audible noise at 1 Meter: 55dBA 55dBA 55dBA

online Thermal Dissipation: 1535BTU/hr 2216BTU/hr 2216BTU/hr

Conformance

regulatory approvals: CSA, FCC Part 15 Class A, UL 1778

reference: SURT8000RMXLT-1TF5, SURT8000XLT-1TF5 SURT10000RMXLT, SURT10000XLT SURT10000RMXLT-2TF5, SURT10000XLT-2TF5

Options:extendedbatteryruntimes,interfacecables,NetBotz® accessories and sensors, SmartSlot expansion chassis, UPS dry-contact management, UPS environmental monitoring card, UPS interface expanders, UPS network management cards, UPS out-of-band management, rack enclosures and accessories, NetShelter 2 post open frame racks, NetShelter 4 post open frame racks, NetShelter SX enclosures, NetShelter VX enclosures, rack fan tray, basic rack PDU, metered rack PDU, power cords, rack automatic transfer switch, switched rack PDU, replacement batteries, extended warranty, installation services, on site service, remote monitoring service, StruXure manager, powerchute business edition, and UPS remote power off interface

52

Sin

gle

Ph

ase

UP

S

SYH4K6RMT-P1

Symmetra®

Single Phase UPS

> Configurable for N+1 internal redundancy> Hot-swappable power modules and batteries> Power modules and battery modules connected in parallel> Standard 2 year warranty> Automatic internal bypass> Emergency power off

Symmetra

Models: Symmetra 2000RMSymmetra 2000RM120/208

Symmetra 4000RMSymmetra 4000RM120/208

Symmetra 6000RM

Symmetra 6000RM120/208

configuration: Rackmount Rackmount Rackmount Rackmount Rackmount Rackmount

Output

output Power capacity: 2000VA / 1400W 2000VA / 1400W 4000VA / 2800W 4000VA / 2800W 6000VA / 4200W 6000VA / 4200W

Max configurable Power: 6000VA / 4200W 6000VA / 4200W 6000VA / 4200W 6000VA / 4200W 6000VA / 4200W 6000VA / 4200W

nominal output Voltage: 208V, 240V 120V, 208 / 240V 208V, 240V 120V, 208 / 240V 208V, 240V 120V, 208 / 240V

waveform Type: Sine wave Sine wave Sine wave Sine wave Sine wave Sine wave

output connections:(2) NEMA L6-20R, (1) NEMA L6-30R

(12) NEMA 5-20R, (2) NEMA L6-20R

(2) NEMA L6-20R, (1) NEMA L6-30R

(12) NEMA 5-20R, (2) NEMA L6-20R

(2) NEMA L6-20R, (1) NEMA L6-30R

(12) NEMA 5-20R, (2) NEMA L6-20R

Input

nominal input Voltage: 208V 208V 208V 208V 208V 208V

input Frequency (auto sensing): 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz 50/60Hz ±3Hz

input connections: Hard Wire 3-wire, NEMA L6-30P

cord length: 1.8m / 5.9ft 1.8m / 5.9ft 1.8m / 5.9ft 1.8m / 5.9ft 1.8m / 5.9ft 1.8m / 5.9ft

bypass: Internal Bypass (Auto and Manual)

Batteries and Runtime

battery Type: Maintenance-free sealed Lead-Acid, leakproof

Typical recharge Time (hrs): 4 4 4 4 4 3

replacement battery cartridge: SYBT2 SYBT2 SYBT2 SYBT2 SYBT2 SYBT2

rbc™ Quantity: 1 to 4 1 to 4 1 to 2 1 to 2 - -

runtime Full / Half load (min): 12.6 / 29.8 12.3 / 28.4 12.7 / 30.2 12.5 / 29.5 12.7 /30.3 12.6 / 29.8

Communication and Management

interface Port(s):DB-9, RS-232, RJ-45 BaseT ethernet for webb/SNMP mgmt

UPS Network Management Card w/ Environmental Monitoring, DB-9, RS-232, RJ-45 Base-T ethernet for web/ SNMP management

SmartSlot™ interface Qty: 2 1 1 1 1 1

control Panel: LED status display with load and battery bar-graphs and On Line, On Battery, Replace Battery, and Overload Indicators

audible alarm: Alarm when on battery, low battery alarm

Mechanical

Dimensions (in/mm):14 x 19 x 28.8 / 355.6 x 482.6 x 731.5

17.5 x 19 x 28.8 / 444.5 x 482.6 x 731.5

14 x 19 x 28.8 / 355.6 x 482.6 x 731.5

17.5 x 19 x 28.8 / 444.5 x 482.6 x 731.5

14 x 19 x 28.8 / 355.6 x 482.6 x 731.5

17.5 x 19 x 28.8 / 444.5 x 482.6 x 731.5

rack Height: 8RU 10RU 8RU 10RU 8RU 10RU

net weight (lb/kg): 164 / 74.4 259 / 117.5 229 / 103.9 324 / 147 294 / 133.4 389 / 176.4

Environmental

Temperature: 0 to 40˚C / 32 to 104˚F

Humidity: 0 to 95% 0 to 95% 0 to 85% 0 to 95% 0 to 95% 0 to 95%

elevation: 0 to 3000m / 0 to 10000ft

Storage Temperature: -15 to 45˚C / 5 to 113˚F

audible noise at 1 Meter: 60dBA 60dBA 60dBA 60dBA 60dBA 60dBA

online Thermal Dissipation: 430BTU/hr 843BTU/hr 1181BTU/hr 1686BTU/hr 1771BTU/hr 2529BTU/hr

Conformance

regulatory approvals: CSA, FCC Part 15 Class A, UL 1778

reference: SYH2K6RMT SHY2K6RMT-P1 SYH4K6RMT SHY4K6RMT-P1 SYH6K6RMT SHY6K6RMT-P1

Options:extendedbatteryruntimes,interfacecables,NetBotz® accessories and sensors, SmartSlot expansion chassis, UPS dry-contact management, UPS environmental monitoring card, UPS interface expanders, UPS network management cards, UPS out-of-band management, rack enclosures and accessories, NetShelter 2 post open frame racks, NetShelter 4 post open frame racks, NetShelter SX enclosures, NetShelter VX enclosures, rack fan tray, basic rack PDU, metered rack PDU, power cords, rack automatic transfer switch, switched rack PDU, replacement batteries, extended warranty, installation services, on site service, remote monitoring service, StruXure manager, powerchute business edition, and UPS remote power off interface

53

Sin

gle P

hase U

PS

Symmetra® lXSingle Phase UPS

> Modular design

> Power modules and battery modules connected in parallel

> Standard 2 year repair or replace

> Emergency power off SYA12K16P

Symmetra lX

Models: Symmetra 4/8KLX Symmetra 4/8LX-RM Symmetra 8/8KLX Symmetra 8/8KLX-RM Symmetra 8/16KLX

configuration: Tower Rackmount Tower Rackmount Tower

Output

output Power capacity: 4000VA / 3200W 4000VA / 3200W 8000VA / 6400W 8000VA / 6400W 8000VA / 6400W

Max configurable Power: 8000VA / 6400W 8000VA / 6400W 8000VA / 6400W 8000VA / 6400W 16kVA / 12.8kW

nominal output Voltage: 120V, 208V, Configurable for 120/208 or 120/240 output voltage

waveform Type: Sine wave Sine wave Sine wave Sine wave Sine wave

output connections:(1) Hard Wire 4-wire (2PH+N+G)

(1) Hard Wire 4-wire (2PH+N+G), (2) NEMA L14-30R, (4) NEMA L5-20R

(1) Hard Wire 4-wire (2PH+N+G)

(1) Hard Wire 4-wire (2PH+N+G), (2) NEMA L14-30R, (4) NEMA L5-20R

(1) Hard Wire 4-wire (2PH+N+G)

Input

nominal input Voltage: 208V, 240V 208V, 240V 208V, 240V 208V, 240V 208V, 240V

input Frequency (auto sensing): 45 to 65Hz 45 to 65Hz 45 to 65Hz 45 to 65Hz 45 to 65Hz

input connections: Hard Wire 4-wire (2PH+N+G)

bypass: Internal Bypass (Auto and Manual)

Batteries and Runtime

battery Type: Maintenance-free sealed Lead-Acid, leakproof

included battery Modules: 1 1 2 2 2

available battery Slots: 1 1 2 2

Typical recharge Time (hrs): 3 3 3 3 3

replacement battery cartridge: SYBT5 SYBT5 SYBT5 SYBT5 SYBT5

runtime Full / Half load (min): 5.9 / 16.9 5.9 / 16.9 5.9 / 17 5.9 / 17 5.9 / 17

Communication and Management

interface Port(s): DB-9 RS-232, Smart-Slot DB-9 RS-232, Smart-Slot DB-9 RS-232, Smart-Slot DB-9 RS-232, Smart-Slot DB-9 RS-232, Smart-Slot

SmartSlot™ interface Qty: UPS Network Management Card w/ Environmental Monitoring

control Panel: Multi-function LCD status and control console

audible alarm: Audible and visible alarms prioritized by severity

Mechanical

Dimensions (in/mm):26 x 4 x 28.6/ 660 x 483 x 726

22.5 x 18.6 x 27.1 / 572 x 472 x 688

23.7 x 19 x 28.6 / 602 x 483 x 726

22.5 x 18.6 x 27.1 / 572 x 472 x 688

36.8 x 19 x 28.6 / 937 x 483 x 726

rack Height: - 13RU - 13RU -

net weight (lb/kg): 347.7 / 157.7 295.6 / 134.1 444.9 / 201.8 392.8 / 178.2 484 / 219.6

Environmental

Temperature: 0 to 40˚C / 32 to 104˚F

Humidity: 0 to 95% 0 to 95% 0 to 95% 0 to 95% 0 to 95%

elevation: 0 to 3000m / 0 to 10000ft

Storage Temperature: -15 to 45˚C / 5 to 113˚F

audible noise at 1 Meter: 62dBA 62dBA 62dBA 62dBA 62dBA

online Thermal Dissipation: 3485BTU/hr 3707BTU/hr 3485BTU/hr 3707BTU/hr 4995BTU/hr

Conformance

regulatory approvals: CSA, FCC Part 15 Class A, UL 1778

reference: SYA4K8P SYA4K8RMP SYA8K8P SYA8K8RMP SYA8K16P

Options:extendedbatteryruntimes,interfacecables,NetBotz® accessories and sensors, SmartSlot expansion chassis, UPS dry-contact management, UPS environmental monitoring card, UPS interface expanders, UPS network management cards, UPS out-of-band management, rack enclosures and accessories, NetShelter 2 post open frame racks, NetShelter 4 post open frame racks, NetShelter SX enclosures, NetShelter VX enclosures, rack fan tray, basic rack PDU, metered rack PDU, power cords, rack automatic transfer switch, switched rack PDU, replacement batteries, extended warranty, installation services, on site service, remote monitoring service, StruXure manager, powerchute business edition, and UPS remote power off interface

54

Sin

gle

Ph

ase

UP

S

Symmetra® lXSingle Phase UPS

> Configurable for N+1 internal redundancy

> Hot-swappable power modules and batteries

> Automatic internal bypass

SYA4K8P

Symmetra lX

Models: Symmetra 8/16KLX-E Symmetra 8/16KLX-RM Symmetra 12/16KLX Symmetra 12/16KLX-E

configuration: Tower Rackmount Tower Tower

Output

output Power capacity: 8000VA / 6400W 8000VA / 6400W 12kVA / 9600W 12kVA / 9600W

Max configurable Power: 16kVA / 12.8kW 16kVA / 12.8kW 16kVA / 12.8kW 16kVA / 12.8kW

nominal output Voltage: 120V, 208V, Configurable for 120/208 or 120/240 output voltage

waveform Type: Sine wave Sine wave Sine wave Sine wave

output connections:(1) Hard Wire 4-wire (2PH+N+G)

(1) Hard Wire 4-wire (2PH+N+G), (4) NEMA L14-30R, (8) NEMA L5-20R

(1) Hard Wire 4-wire (2PH+N+G)

Input

nominal input Voltage: 208V, 240V 208V, 240V 208V, 240V 208V, 240V

input Frequency (auto sensing): 45 to 65Hz 45 to 65Hz 45 to 65Hz 45 to 65Hz

input connections: Hard Wire 4-wire (2PH+N+G)

bypass: Internal Bypass (Auto and Manual)

Batteries and Runtime

battery Type: Maintenance-free sealed Lead-Acid, leakproof

included battery Modules: 9 2 3 9

available battery Slots: 4 2 1 4

Typical recharge Time (hrs): 7.5 3 3 7.5

replacement battery cartridge: SYBT5 SYBT5 SYBT5 SYBT5

runtime Full / Half load (min): 49.3 / 106.4 5.9 / 17 6 / 17.1 30.1 / 66.9

Communication and Management

interface Port(s): DB-9 RS-232, Smart-Slot DB-9 RS-232, Smart-Slot DB-9 RS-232, Smart-Slot DB-9 RS-232, Smart-Slot

SmartSlot™ interface Qty: UPS Network Management Card w/ Environmental Monitoring

control Panel: Multi-function LCD status and control console

audible alarm: Audible and visible alarms prioritized by severity

Mechanical

Dimensions (in/mm): 59.7 x 19 x 28.6 / 1516 x 483 x 726 32.9 x 18.6 x 27.1 / 836 x 472 x 688 36.8 x19 x 28.6 / 937 x 483 x 726 59.7 x 19 x 28.6 / 1516 x 483 x 726

rack Height: - 19RU - -

net weight (lb/kg): 1044.2 / 473.6 438 / 198.7 581.2 / 263.6 1077.3 / 488.6

Environmental

Temperature: 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F

Humidity: 0 to 95% 0 to 95% 0 to 95% 0 to 95%

elevation: 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft

Storage Temperature: -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F

audible noise at 1 Meter: 62dBA 62dBA 62dBA 62dBA

online Thermal Dissipation: 4995BTU/hr 4995BTU/hr 4995BTU/hr 4995BTU/hr

Conformance

regulatory approvals: CSA, FCC Part 15 Class A, UL 1778

reference: SYA8K16PXR SYA8K16RMP SYA12K16P SYA12K16PXR

Options:extendedbatteryruntimes,interfacecables,NetBotz® accessories and sensors, SmartSlot expansion chassis, UPS dry-contact management, UPS environmental monitoring card, UPS interface expanders, UPS network management cards, UPS out-of-band management, rack enclosures and accessories, NetShelter 2 post open frame racks, NetShelter 4 post open frame racks, NetShelter SX enclosures, NetShelter VX enclosures, rack fan tray, basic rack PDU, metered rack PDU, power cords, rack automatic transfer switch, switched rack PDU, replacement batteries, extended warranty, installation services, on site service, remote monitoring service, StruXure manager, powerchute business edition, and UPS remote power off interface

55

Sin

gle P

hase U

PS

Symmetra® lXSingle Phase UPS

> Automatic restart of loads after UPS shutdown

> Field-replaceable power distribution panel

> Scalable power capacity and runtime

Symmetra lX

Models: Symmetra 12/16KLX-RM Symmetra 16/16KLX Symmetra 16/16KLX-E Symmetra 16/16KLX-RM

configuration: Rackmount Tower Tower Rackmount

Output

output Power capacity: 12kVA / 9600W 16kVA / 12.8kW 16kVA / 12.8kW 16kVA / 12.8kW

Max configurable Power: 16kVA / 12.8kW 16kVA / 12.8kW 16kVA / 12.8kW 16kVA / 12.8kW

nominal output Voltage: 120V, 208V, Configurable for 120/208 or 120/240 output voltage

waveform Type: Sine wave Sine wave Sine wave Sine wave

output connections:(1) Hard Wire 4-wire (2PH+N+G), (4) NEMA L14-30R, (8) NEMA L5-20R

(1) Hard Wire 4-wire (2PH+N+G)

(1) Hard Wire 4-wire (2PH+N+G)

(1) Hard Wire 4-wire (2PH+N+G), (4) NEMA L14-30R, (8) NEMA L5-20R

Input

nominal input Voltage: 208V, 240V 208V, 240V 208V, 240V 208V, 240V

input Frequency (auto sensing): 45 to 65Hz 45 to 65Hz 45 to 65Hz 45 to 65Hz

input connections: Hard Wire 4-wire (2PH+N+G)

bypass: Internal Bypass (Auto and Manual)

Batteries and Runtime

battery Type: Maintenance-free sealed Lead-Acid, leakproof

included battery Modules: 3 4 9 4

available battery Slots: 1 - 4 -

Typical recharge Time (hrs): 3 3 7.5 3

replacement battery cartridge: SYBT5 SYBT5 SYBT5 SYBT5

runtime Full / Half load (min): 6 / 17.1 6 / 17.1 20.8 / 47.8 6 / 17.1

Communication and Management

interface Port(s): DB-9 RS-232, Smart-Slot DB-9 RS-232, Smart-Slot DB-9 RS-232, Smart-Slot DB-9 RS-232, Smart-Slot

SmartSlot™ interface Qty: UPS Network Management Card w/ Environmental Monitoring

control Panel: Multi-function LCD status and control console

audible alarm: Audible and visible alarms prioritized by severity

Mechanical

Dimensions (in/mm): 32.9 x 18.6 x 27.1 / 836 x 472 x 688 36.8 x 19 x 28.6 / 726 x 483 x 726 59.7 x 19 x 28.6 / 726 x 483 x 726 36.8 x 19 x 28.6 / 726 x 483 x 726

rack Height: 19RU - - 19RU

net weight (lb/kg): 535.1 / 242.7 678.4 / 307.7 1110.3 / 503.6 632.3 / 286.8

Environmental

Temperature: 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F 0 to 40˚C / 32 to 104˚F

Humidity: 0 to 95% 0 to 95% 0 to 95% 0 to 95%

elevation: 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft 0 to 3000m / 0 to 10000ft

Storage Temperature: -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F -15 to 45˚C / 5 to 113˚F

audible noise at 1 Meter: 62dBA 62dBA 62dBA 62dBA

online Thermal Dissipation: 4995BTU/hr 4995BTU/hr 4995BTU/hr 4995BTU/hr

Conformance

regulatory approvals: CSA, FCC Part 15 Class A, UL 1778

reference: SYA12K16RMP SYA16K16P SYA16K16PXR SYA16K16RMP

Options:extendedbatteryruntimes,interfacecables,NetBotz® accessories and sensors, SmartSlot expansion chassis, UPS dry-contact management, UPS environmental monitoring card, UPS interface expanders, UPS network management cards, UPS out-of-band management, rack enclosures and accessories, NetShelter 2 post open frame racks, NetShelter 4 post open frame racks, NetShelter SX enclosures, NetShelter VX enclosures, rack fan tray, basic rack PDU, metered rack PDU, power cords, rack automatic transfer switch, switched rack PDU, replacement batteries, extended warranty, installation services, on site service, remote monitoring service, StruXure manager, powerchute business edition, and UPS remote power off interface

SYA8K16RMP

56

Sin

gle

Ph

ase

UP

S

1600eP SeriesSingle Phase UPS

> Freestanding configurations 3.6 to 22kVA

> Compact footprint and high-power density

> Hot swappable batteries and slide-out battery trays

> Standard external battery connector for extended runtime

> Optional features include modular receptacle panel and Internal SNMP/web browser interface

1600eP Series

1600EP Series Dual Conversion

3600EP 6000EP 8000EP 10000EP 14000EP 18000EP 22000EP

output Power rating: 3.6kVA / 3.06kW 6kVA / 5.1kW 8kVA / 6.8kw 10kVA / 8.5kW 14kVA / 11.9kW 18kVA / 15.3kW 22kVA / 18.7kW

output Power Factor: 0.85 0.85 0.85 0.85 0.85 0.85 0.85

input Voltage: 208/240Vac 208/240Vac 208/240Vac 208/240Vac 208/240Vac 208/240Vac 208/240Vac

output Voltage: 120/208/240Vac 120/208/240Vac 120/208/240Vac 120/208/240Vac 120/208/240Vac 120/208/240Vac 120/208/240VacTypical efficiency- ac/ac 100% load:

85% 85% 85% 85% 85% 85% 85%

Typical Heat output (bTu/hr): 1588 2610 3482 4352 6092 7832 9600

Mechanical

Dimensions (in/mm):10 x 27.5 x 33 / 254 x 698.5 x 838.2

10 x 27.5 x 33 / 254 x 698.5 x 838.2

13 x 28.3 x 33.5 / 330.2 x 717.6 x 222.3

13 x 28.3 x 33.5 / 330.2 x 717.6 x 850.9

17.5 x 39 x 34.8 / 444.5 x 993 x 883.9

17.5 x 39 x 34.8 / 444.5 x 993 x 883.9

17.5 x 39 x 34.8 / 444.5 x 993 x 883.9

weight (lb/kg): 365 / 169.6 385 / 174.6 490 / 222.3 490 / 222.3 620 / 281.2 750 / 340.2 755 / 343

Internal Battery Runtime

Full load @ .85 Power Factor: 14min 7min 7min 5min 7min 5min 3min

Half load @ .85 Power Factor: 42min 21min 21min 15min 21min 15min 9minNote:Internalruntimeat.7powerfactorisapproximately30%more.Externalbatteryruntimeoptionsareavailablefrom30minutesto8hours.PleasecontactyourAlphasalesrepresentativeformore information.

Specifications

input Frequency: 45 to 65Hz Auto sensing

output Frequency: 60Hz, ±0.1%

operating input Voltage range: -30 to 10%

output Voltage regulation: ±3% Max., ±1% Typical

overload capacity: 125% for 10min, 150% for 10sec, 1000% for 1 Cycle

Status and control Features:

LCDReadout:ACinputandoutputvoltage, input and output frequency, output current, battery voltage and test results, number of discharges and faultsTouch pad UPS/Bypass operationEmergency power off terminalsUPS inverter/bypass mode

Standard Features:

UPS operation Alarm reset operation Slide out battery trays LED display with key pad status LEDs Hot swappable batteries Internal SNMP device with optional SNMP/Web slide in cardRS-232 interface External battery interface

optional Features:Maintenance bypass Internal SNMP/Web slide-in card Modular receptacle

Warranty

uPS:Three-year parts and labor on-site in continental US only

batteries: Two-year full

1600EP Series

57

Th

ree Ph

ase UP

S

Triniti™ 4200 SeriesThree Phase UPS

Triniti 4200 Series

Power Ratinginput Power Factor correction:

>0.95 PF (lagging)

input Harmonic currents: <3% THD (typical)

input Frequency range: 60Hz, ±5%

load crest Factor: ≤3

overload capacity inverter: 125% for 90sec, 150% for 30sec

overload capacity bypass: 125% for 10ms, 1000% for 1 cycle

neutral conductor Size: 1.73 x conductor

load inrush current Protection:Automatically transfers to bypass then retransfers to inverter

Typical efficiency ac/ac: 87%

output Frequency: 60Hz, ±0.1%

Status and Control

ac input Present: Input and output frequency

inverter operating: Operating status menu

uPS on bypass: Diagnostic status menu

uPS on battery: DB9 dry contact interface

Fault: RS232 communications

input and output Voltage: Emergency power off switch

output current indicator: Run/Stop key switch

battery Voltage indicator:Terminal block (input/output power connector) Internal maintenance bypass (except on 80kVA)

optional Features: External maintenance bypass, SNMP

Warranty

3 year parts and labor, 2 years on batteries. See warranty statement for further details, conditions and limitations.

Model Triniti 15 Triniti 25 Triniti 50 Triniti 80

output Power rating: 15kVA / 12kW 25kVA / 20kW 50kVA / 40kW 80kVA / 64kW

input Voltage (-15 to 10%; -30% if derated): 208/120 4 wire + gnd 208/480 3 wire + gnd 208/480 3 wire + gnd 208/480 3 wire + gnd

output Voltage (±2% regulation balanced load): 208/120 4 wire + gnd 208/120 4 wire + gnd 208/120 4 wire + gnd 208/120 4 wire + gnd

input circuit breaker @ 208V: 60A 90A 175A 300A

output current Per Phase @ 208/120V: 41.7A 69.4A 138A 222A

Typical Heat output (KbTu/Hr): 5.73 7.6 17.73 24.27

audible noise at 1 Meter From Front Panel: <60dBA <60dBA <65dBA <65dBA

Internal Battery Runtime

Full load @ 0.7 Power Factor: 10min 5min 5min External Battery

Half load @ 0.7 Power Factor: 30min 15min 15min Pack Options*

Mechanical

Dimensions (in/mm): 20 x 36.3 x 59.8 / 508 x 922 x 1518.9

20 x 36.3 x 59.8 / 508 x 922 x 1518.9

35.6 x 37.6 x 59.8 /904.2 x 939.8 x 1518.9

44 x 31 x 74 / 1117.6 x 787.4 x 1879.6

weight (lb/kg): 900 / 408.2 910 / 412.7 2548 / 1155.8 2450 / 111.3

* 4 to 64min runtime options

> 15, 25, 50 and 80kVA power ratings

> 100% front access

> Internal maintenance bypass (except on 80kVA)

>“ActiveFrontEnd”providestotalpowerfactor correction and utility cost savings

> Internal batteries reduce footprint for easy installation (except on 80kVA)

Triniti 80kVA

Triniti 15kVA

58

Th

ree

Ph

ase

UP

S

galaxyThree Phase UPS

> Power ranges 10, 15, 20 and 30kVA

> True online double conversion technology

> Network-based power management

> Input Power Factor Correction (PFC)

> All-in-one complete solution

> Parallel Ready

galaxy

Output Power Rating 10kVA 15kVA 20kVA 30kVA

Input

Voltage: 208 / 220 / 480 / 600V 208 / 220 / 480 / 600V 208 / 220 / 480 / 600V 208 / 220 / 480 / 600V

Frequency: 60Hz (-25 to 8%) 60Hz (-25 to 8%) 60Hz (-25 to 8%) 60Hz (-25 to 8%)

Power Factor: <0.99 <0.99 <0.99 <0.99

current Distortion (THD): <3% <3% <3% <3%

current (a @ 208V): 28 42 56 83

breaker (@208): 40 60 80 125

Output

Voltage: 208 (220 / 480 / 600) 208 (220 / 480 / 600) 208 (220 / 480 / 600) 208 (220 / 480 / 600)

Frequency: 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable)

Transient response: ±3% for 0 to 100% to 0% ±3% for 0 to 100% to 0% ±3% for 0 to 100% to 0% ±3% for 0 to 100% to 0%

Voltage Distortion THD: <3% L-L and L-N <3% L-L and L-N <3% L-L and L-N <3% L-L and L-N

inverter overload: 120% for 1min - 145% for 30 sec 120% for 1min, 145% for 30 sec 120% for 1min, 145% for 30 sec 120% for 1min, 145% for 30 sec

bypass overload: 10x nominal current - 1 cycle 10x nominal current - 1 cycle 10x nominal current - 1 cycle 10x nominal current - 1 cycle

output current (a @ 208V): 28 42 56 83

Heat rejection (max bTus): 4,821 7,232 8,895 13,342

Batteries

backup Time (minutes)1: 11 / 39 / 60 7 / 22 / 35 / 55 15 / 24 / 38 8 / 12 / 21

Mechanical

cabinet Mechanical Dimensions (in/cm):32.8 x 40.1 x 62.4 / 83.8 x 101.8 x 158.5

32.8 x 40.1 x 62.4 / 83.8 x 101.8 x 158.5

32.8 x 40.1 x 62.4 / 83.8 x 101.8 x 158.5

32.8 x 40.1 x 62.4 / 83.8 x 101.8 x 158.5

Max. weight2 (lb/kg): 2565 / 1163.5 2565 / 1163.5 2565 / 1163.5 2565 / 1163.5

Micro Cabinet3 Dimensions

Micro cabinet3 Dimensions (in/cm):23 x 35.5 x 48.5 / 58.4 x 90.2 x 123.2

23 x 35.5 x 48.5 / 58.4 x 90.2 x 123.2

— —

Max. weight (lb/kg): 830 / 376.5 830 / 376.5 — —

Auxiliary Cabinets

Maintenance bypass cabinet (in/cm):18.8 x 41.1 x 62.4 / 47.7 x 104.4 x 158.5

18.8 x 41.1 x 62.4 / 47.7 x 104.4 x 158.5

18.8 x 41.1 x 62.4 / 47.7 x 104.4 x 158.5

18.8 x 41.1 x 62.4 / 47.7 x 104.4 x 158.5

battery cabinet (in/cm): 23 x 35.5 x 62.4 / 58.4 x 90.2 x 158.5

23 x 35.5 x 62.4 / 58.4 x 90.2 x 158.5

23 x 35.5 x 62.4 / 58.4 x 90.2 x 158.5

23 x 35.5 x 62.4 / 58.4 x 90.2 x 158.5

Max. weight (lb/kg): 2723 / 1235 2723 / 1235 2723 / 1235 2723 / 1235

Standards

Standards: UL 1778, cUL, FCC Class A parts, 15 sub part J Class A, IEC 1000 level 4, IEEE C62.41-B3, NEC, ISO 9001

Notes: 1 11/7min battery times only applicable for micro cabinet. 2 Weight will vary based on battery runtime and input volt options. 3 Micro Cabinet only available in 208/208V. External maintenance bypass distribution options not available with micro cabinet.

Standard Features:

True double conversion online topology, Low audible noise fans (<53dBA), Input power factor correction (IGBT) rectifier, Casters with leveling feet, Input distortion management, Network based software for multi-server control, Digital power quality management system, Dry contact i/o card, (PWM/IGBT inverter), SNMP manageable, Step load voltage stabilization, Intelligent battery management system, color graphic display with multilingual user interface, Fault tolerant architecture, Bottom or top entry, Scalable architecture (10 and 20kVA models), Integrated maintenance bypass (single module only), No extra cabinet for isolation transformer, Four communications ports, Integrated battery bank, 12 month warranty.

Galaxy

59

Th

ree Ph

ase UP

S

galaxy 4000Three Phase UPS

> Power ranges 40, 50, 65 and 75kVA

> True online double conversion technology

> Low UPS to generator sizing

> Power surge stabilization system

> Power factor corrected input SNMP and network based power management options

galaxy 4000

Output Power Rating 40kVA / 32kW 50kVA / 40kW 65kVA / 52kW 75kVA / 60kW

Input

Voltage: 208V 208V 208V 208V

input Frequency: 60Hz (±5%) 60Hz (±5%) 60Hz (±5%) 60Hz (±5%)

Power Factor: >0.98 >0.98 >0.98 >0.98

current Distortion (THD): <3% @ Full load <3% @ Full load <3% @ Full load <3% @ Full load

current (a @ 208V): 102 127 166 191

Output

Voltage: 208V 208V 208V 208V

Frequency: 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable)

Transient response: ±5% for 0 to 100% to 0% ±5% for 0 to 100% to 0% ±5% for 0 to 100% to 0% ±5% for 0 to 100% to 0%

Voltage Distortion THD: <1% L-L and L-N <1% L-L and L-N <1% L-L and L-N <1% L-L and L-N

inverter overload 130%: 1min 1min 1min 1min

inverter overload 145%: 30 sec 30 sec 30 sec 30 sec

bypass overload: 10x nominal current - 1 cycle 10x nominal current - 1 cycle 10x nominal current - 1 cycle 10x nominal current - 1 cycle

output current (a @ 208V): 111 139 180 208

Heat rejection (max bTus): 14,900 18,700 24,200 28,000

Runtimes @ 100% Load

1 x 285w/cell: 12 9 6 -

1 x 370w/cell: 20 14 9 8

1 x 500w/cell: 28 22 15 11

2 x 370w/cell: 47 36 25 22

2 x 500w/cell: 67 52 38 31

3 x 500w/cell: 98 85 60 53

4 x 500w/cell: 136 115 85 72

Mechanical Specifications

Standard cabinet Dimensions (in/mm):33.5 x 35.6 x 72.1 / 850 x 901 x 1831

33.5 x 35.6 x 72.1 / 850 x 901 x 1831

33.5 x 35.6 x 72.1 / 850 x 901 x 1831

33.5 x 35.6 x 72.1 / 850 x 901 x 1831

weight (lb/kg): 1235 / 560 1235 / 560 1235 / 560 1235 / 560

battery cabinet Dimensions (in/mm):26.5 x 35.5 x 72.1 / 673 x 901 x 1831

26.5 x 35.5 x 72.1 / 673 x 901 x 1831

26.5 x 35.5 x 72.1 / 673 x 901 x 1831

26.5 x 35.5 x 72.1 / 673 x 901 x 1831

weight (lb/kg): 2045 / 928 2045 / 928 2045 / 928 2045/928

battery cabinet Dimensions (in/mm):33.5 x 35.6 x 72.1 / 850 x 901 x 1831

33.5 x 35.6 x 72.1 / 850 x 901 x 1831

33.5 x 35.6 x 72.1 / 850 x 901 x 1831

33.5 x 35.6 x 72.1 / 850 x 901 x 1831

weight (lb/kg): 2745 / 1245 2745 / 1245 2745 / 1245 2745 / 1245

Standards

Standards: ISO 9001, UL 1778, cUL, FCC Part 15, subpart J, Class A, NEMA PE 1, NEMA 250, NFPA 70, IEC 10000 (801) level 4, OSHA

Standard Features:

True double conversion online topology, Input power factor correction (IGBT rectifier), Dual input, Input distortion management, Digital power quality management system (PWM/IGBT inverter), Step load voltage stabilization, Intelligent battery management system, Fault tolerant architecture, Casters with stabilizing feet, Network based software for multi-server control, Dry contact I/O card, SNMP manageable, Graphic display with multilingual user interface, Bottom or top entry, Four communications ports.

Galaxy 4000

60

Th

ree

Ph

ase

UP

S

Symmetra® PXThree Phase UPS

> Configurable for N+1 internal redundancy

> Redundant intelligence modules

> Power modules and battery modules connected in parallel

> Scalable power capacity and runtime

> Emergency power off SY10K40F

Symmetra PX

Models:Symmetra 80/80PX

Symmetra 70/80PX

Symmetra 60/80PX

Symmetra 50/80PX

Symmetra 40/80PX

Symmetra 40/40PX

Output

output Power capacity: 80kVA / 80kW 70kVA / 70kW 60kVA / 60kW 50kVA / 50kW 40kVA / 40kW 40kVA / 40kW

Max configurable Power: 80kVA / 80kW 80kVA / 80kW 80kVA / 80kW 80kVA / 80kW 80kVA / 80kW 40kVA / 40kW

nominal output Voltage: 120V, 208V, 208V 3PH 120V, 208V, 208V 3PH 120V, 208V, 208V 3PH 120V, 208V, 208V 3PH 120V, 208V, 208V 3PH 120V, 208V, 208V 3PH

waveform Type: Sine wave Sine wave Sine wave Sine wave Sine wave Sine wave

output Frequency (sync to mains): 57 to 63Hz for 60Hz nominal

output connections: (1) Hard Wire 5-wire (3PH + N + G), (1) Screw Terminal

output Voltage Tolerance: - - - - - -

Input

nominal input Voltage: 208V 3PH 208V 3PH 208V 3PH 208V 3PH 208V 3PH 208V 3PH

input Frequency (auto sensing): 50/60Hz ±5Hz 50/60Hz ±5Hz 50/60Hz ±5Hz 50/60Hz ±5Hz 50/60Hz ±5Hz 50/60Hz ±5Hz

input connections: Hard Wire 5-wire (3PH + N + G)

bypass: Built-in Static Bypass Built-in Static Bypass Built-in Static Bypass Built-in Static Bypass Built-in Static Bypass Built-in Static Bypass

Max bypass input current: 162A 162A 162A 162A 162A 162A

bypass Protection Device: 175A 175A 175A 175A 175A 175A

Batteries and Runtime

battery Type: No internal battery - uses external battery system Maintenance-free sealed Lead-Acid, leakproof

included battery Modules: 8 7 6 5 4 4available battery Slots: - 1 2 3 4 -Typical recharge Time (hrs)**: 2 2 2 2 2 2replacement battery cartridge: SYBT4 SYBT4 SYBT4 SYBT4 SYBT4 SYBT4

runtime Full / Half load (min): 3.5 / 13.7 3.5 / 13.7 3.5 / 13.7 3.5 / 13.7 3.6 / 13.9 3.5 / 14

Communication and Management

interface Port(s): Contact Closure, RJ-45 10 Base-T ethernet for web/ SNMP/ Telnet management, Smart-Slot

Pre-installed SmartSlot: AP9617 AP9617 AP9617 AP9617 AP9617 AP9617

control Panel: - - - - - Multi-function LCD status and control console

audible alarm: Alarm when on battery, distinctive low battery alarm, configurable delays

Mechanical

Dimensions (in/mm):81.5 x 48 x 35.5 / 2070 x 1219 x 902

81.5 x 48 x 35.5 / 2070 x 1219 x 902

81.5 x 48 x 35.5 / 2070 x 1219 x 902

81.5 x 48 x 35.5 / 2070 x 1219 x 902

81.5 x 48 x 35.5 / 2070 x 1219 x 902

81.5 x 23.6 x 35.5 / 2070 x 600 x 902

rack Height: 42RU 42RU 42RU 42RU 42RU 42RUnet weight (lb/kg): 3262.8 / 1480 3005.3 / 1363.2 2747.8 / 1246.4 2490.2 / 1129.6 2232.7 / 1012.7 1708.6 / 775

EnvironmentalTemperature: 0 to 40˚C / 32 to 104˚F -50 to 40˚C / -58 to 104˚F 0 to 40˚C / 32 to 104˚FHumidity: 0 to 95% 0 to 95% 0 to 95% 0 to 95% 0 to 95% 0 to 95%

elevation: 0 to 3000m / 0 to 10000ft

Storage Temperature: -15 to 40˚C / 5 to 104˚Faudible noise at 1 Meter: 71dBA 71dBA 71dBA 71dBA 64dBA 64dBAonline Thermal Dissipation: 22744BTU/hr 20797BTU/hr 17826BTU/hr 14855BTU/hr 11884BTU/hr 11611BTU/hr

Conformance

regulatory approvals: cUL Listed, CSA, FCC Part 15 Class A, ISO 14001, ISO 9001, UL 1778

cUL Listed, EN 50091-1, EN 50091-2, FCC Part 15 Class A, ISO 14001, ISO 9001, UL 1778, UL 60950

reference: SY80K80F SY70K80F SY60K80F SY50K80F SY40K80F SY40K40F

**The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.

61

Th

ree Ph

ase UP

S

Symmetra® PXThree Phase UPS

> Front-access servicing

> Programmable frequency

> LED Status indicators

> LCD display

> Standard 1 year repair or replaceSY10K80F

Symmetra PX

Models:Symmetra 30/80PX

Symmetra 30/40PX

Symmetra 20/80PX

Symmetra 20/40PX

Symmetra 10/80PX

Symmetra 10/40PX

Output

output Power capacity: 30kVA / 30kW 30kVA / 30kW 20kVA / 20kW 20kVA / 50kW 10kVA / 10kW 10kVA / 10kW

Max configurable Power: 80kVA / 80kW 40kVA / 40kW 80kVA / 80kW 40kVA / 40kW 80kVA / 80kW 40kVA / 40kW

nominal output Voltage: 120V, 208V, 208V 3PH 120V, 208V, 208V 3PH 120V, 208V, 208V 3PH 120V, 208V, 208V 3PH 120V, 208V, 208V 3PH 120V, 208V, 208V 3PH

waveform Type: Sine wave Sine wave Sine wave Sine wave Sine wave Sine wave

output Frequency (sync to mains): 57 to 63Hz for 60Hz nominal

output connections: (1) Hard Wire 5-wire (3PH + N + G), (1) Screw Terminals

output Voltage Tolerance: - - - - - ±1% static and ±5% at 100% load step

Input

nominal input Voltage: 208V 3PH 208V 3PH 208V 3PH 208V 3PH 208V 3PH 208V 3PH

input Frequency (auto sensing): 50/60Hz ±5Hz 50/60Hz ±5Hz 50/60Hz ±5Hz 50/60Hz ±5Hz 50/60Hz ±5Hz 50/60Hz ±5Hz

input connections: Hard Wire 5-wire (3PH + N + G)bypass: Built-in Static Bypass Built-in Static Bypass Built-in Static Bypass Built-in Static Bypass Built-in Static Bypass Built-in Static BypassMax bypass input current: 162A 162A 162A 162A 162A 162Abypass Protection Device: 175A 175A 175A 175A 175A 175A

Batteries and Runtime

battery Type: No internal battery - uses external battery system

Maintenance-free sealed Lead-Acid, leakproof

No internal battery - uses external battery system

Maintenance-free sealed Lead-Acid, leakproof

No internal battery - uses external battery system

Maintenance-free sealed Lead-Acid, leakproof

included battery Modules: 3 3 2 2 1 1available battery Slots: 5 1 6 2 7 3Typical recharge Time (hrs)**: 2 2 2 2 2 2replacement battery cartridge: SYBT4 SYBT4 SYBT4 SYBT4 SYBT4 SYBT4runtime Full / Half load (min): 3.5 / 13.7 3.7 / 14.2 3.5 / 13.6 3.5 / 13.5 3.6 / 13.8 3.4 / 13.5

Communication and Management

interface Port(s): Contact Closure, RJ-45 10 Base-T ethernet for web/ SNMP/ Telnet management, Smart-Slot

RJ-45 10 Base-T ethernet for web/ SNMP/ Telnet management, SmartSlot

Contact Closure, RJ-45 10 Base-T ethernet for web/ SNMP/ Telnet management, Smart-Slot

Pre-installed SmartSlot: AP9617 AP9617 AP9617 AP9617 AP9617 AP9617

control Panel: - Multi-function LCD status and control console - Multi-function LCD status

and control console - Multi-function LCD status and control console

audible alarm: Alarm when on battery, distinctive low battery alarm, configurable delays

Mechanical

Dimensions (in/mm):81.5 x 48 x 35.5 / 2070 x 1219 x 902

81.5 x 23.6 x 35.5 / 2070 x 600 x 902

81.5 x 48 x 35.5 / 2070 x 1219 x 902

81.5 x 23.6 x 35.5 / 2070 x 600 x 902

81.5 x 48 x 35.5 / 2070 x 1219 x 902

81.5 x 23.6 x 35.5 / 2070 x 600 x 902

rack Height: 42RU 42RU 42RU 42RU 42RU 42RU

net weight (lb/kg): 1975.1 / 895.9 1438 / 652.27 1717.6 / 779.1 1167.5 / 529.6 1460.1 / 662.3 897 / 406.8

Environmental

Temperature: 0 to 40˚C / 32 to 104˚F -50 to 40˚C / -58 to 104˚F 0 to 40˚C / 32 to 104˚F

Humidity: 0 to 95% 0 to 95% 0 to 95% 0 to 95% 0 to 95% 0 to 95%

elevation: 0 to 3000m / 0 to 10000ft

Storage Temperature: -15 to 40˚C / 5 to 104˚Faudible noise at 1 Meter: 64dBA 64dBA 64dBA 64dBA 64dBA 64dBAonline Thermal Dissipation: 8913BTU/hr 8913BTU/hr 5942BTU/hr 5942BTU/hr 3381BTU/hr 3381BTU/hr

Conformance

regulatory approvals:

cUL Listed, CSA, FCC Part 15 Class A, ISO 14001, ISO 9001, UL 1778

cUL Recognized, EN 50091-1, EN 50091-2, FCC Part 15 Class A, ISO 14001, ISO 9001, UL 1778, UL 60950

cUL Listed, CSA, FCC Part 15 Class A, ISO 14001, ISO 9001, UL 1778

cUL Listed, EN 50091-1, EN 50091-2, FCC Part 15 Class A, ISO 14001, ISO 9001, UL 1778, UL 60950

cUL Listed, CSA, FCC Part 15 Class A, ISO 14001, ISO 9001, UL 1778

cUL Listed, EN 50091-1, EN 50091-2, EN 50091-3, FCC Part 15 Class A, ISO 14001, ISO 9001, UL 1778, UL 60950

reference: SY30K80F SY30K40F SY20K80F SY20K40F SY10K80F SY10K40F**The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.

62

Th

ree

Ph

ase

UP

S

galaxy Pw SeriesThree Phase UPS

> Parallel modules for capacity or redundancy

> 0.9 output power factor

> Modular design for easy upgrading or expansion

> Field upgradeable power output**

> Generator friendly for low UPS to generator sizing ratios

> Advanced battery management system with automatic self testing

** on 100-200 kVA modules only

galaxy Pw Series

Power Rating 100 kVA/90kW 130 kVA/117kW 150 kVA/135kW

input Voltage: 208 480 480 600 208 480 480 600 208 480 480 600

output Voltage: 208 208 480 600 208 208 480 600 208 208 480 600

nominal input current: 312 135 135 108 415 180 180 144 485 210 210 168

nominal output current: 279 279 121 97 362 362 157 126 418 418 181 145

Dccurrent at nominal Voltage: — — 219 — — 283 — — — — 331 —

efficiency at 100%: — — 92.5% — — 93% — — — — 93% —

Full load Heat rejection (bTus): 40,185 33,929 27,673 40,185 49,661 41,258 33,396 49,661 57,301 47,917 38,534 57,301

uPS Module weight (lb/kg): — — 3050*/1383* — — 3050*/1383* — — — — 3050*/1383* —

Module width (75"H x 33"D): — — 48" — — 48" — — — — 48" —

180 kVA/162kW 200 kVA/180kW 225 kVA/202.5kW

input Voltage (V): 208 480 480 600 208 480 480 600 208 480 480 600

output Voltage (V): 208 208 480 600 208 208 480 600 208 208 480 600

nominal input current (a): 600 260 260 208 692 300 300 240 692 300 300 240

nominal output current (a): 501 501 217 174 556 556 241 217 625 625 271 217

Dc current at nominal Voltage (a): — — 392 — — 438 — — — — 442 —

efficiency at 100%: — — 93% — — 93.5% — — — 93.5% — —

Full load Heat rejection (bTus): 68,762 57,501 46,240 68,762 72,477 59,965 47,453 72,477 73,383 60,715 48,046 73,383

uPS Module weight (lb/kg): — — 3050*/1383* — — 3050*/1383* — — — — 3050*/1383* —

Module width (75"H x 33"D): — — 48" — — 48" — — — — 48" —

*UPS module only, including 50lb. pallet ~ does not include transformer and auxiliary cabinets.

Battery Cabinets 100kVA 130kVA 150kVA 180kVA 200kVA 225kVA

1 x 285w 7 – – – – –

1 x 370w 12 8 6 – – –

1 x 500w 16 10 7 – – –

2 x 285w 21 14 11 8 7 6

2 x 370w 30 22 19 14 12 12

3 x 285w 38 26 21 16 14 13

2 x 500w 45 31 26 19 17 16

3 x 370w 51 37 32 24 22 22

4 x 285w 54 38 32 26 21 21

3 x 500w 75 448 45 37 31 31

4 x 370w 82 54 46 36 33 32

4 x 500w 105 77 63 51 45 44

Standards

Standards: ISO 9001, UL 1778, cUL, NEMA PE 1, NEMA 250, NFPA 70, IEEE 587-1980/ANSI C62.41, OSHA

Standard Features:IGBT/PWM inverter, Low kVAR input filter, LED mimic diagram, Guided operator interface, Advanced battery management system, Modular power assemblies, Front access design, Computer aided self diagnostics, Dry contact relay status array, Top to bottom access models.

Galaxy PW

63

Th

ree Ph

ase UP

S

ePS 7000Three Phase UPS

> High output power factor (0.9 pƒ)

> Low kVAR input filter

> No leading power factor

> High energy efficiency

> Reduced footprint

> High power density

> Fault tolerant architectur

Standard Features

IGBT/PWM inverter, Low kVAR solid state input filter, K-20 output transformer, Redundant fans, Advanced battery management system, Detailed metering system, Fault current management circuitry, Two stage input current limit, Serial and dry contact interface, Local and remote E.P.O circuit, High capacity 100% rated static transfer switch

DC Rating

nominal Voltage: 480Vdc

Environmental Specifications

acoustical noise level: 75dBA at 5ft

operating Temperature: 0 to 40°C / 32 to 104°F

Storage Temperature: -20 to 45°C / -4 to 113°F

Humidity: 0 to 90% non-condensing

Dimensions uPS Module (in/mm):

69 x 82 x 39 / 1752.6 x 2082.8 x 990.6

weight (lb/kg): 6900 / 3129.8

Maintenance bypass cabinet (in/mm) (lb/kg):

22.75 x 82 x 39 / 557.9 x 2082.8 x 990.6 540 / 224.9

bottom entry cabinet (in/mm) (lb/kg):

14 x 82 x 39 / 355.6 x 2082.8 x 990.6 190 / 86.2

Transformer cabinet (in/mm) (lb/kg):

44.75 x 82 x 39 / 1136.7 x 2082.8 x 990.6 3600 / 1632.9

Options:inputisolationtransformer,outputdistribution,externalmaintenancebypass,bottomcable entry, remote alarm status panel, seismic anchors, battery monitoring, battery disconnect, SNMP/Network management card, critical bus synchronization module, graphical user interface with network connection, continuous duty and momentary duty static switch cabinets (SSC)

Input

Voltage: 480 or 600Vac, ±10%, 3 phase, 3 wire + ground

Frequency: 60Hz + 5%

Power Factor: 0.9 lagging with filter

THDi: 7% THDI at full load

reactive current (kVar): <15% of nominal input current

inrush current: up to 600% nominal current for less than one cycle

Power walk-in: 0 to 100% over a 10 second period

Bypass Input

Voltage:Must match rectifier input, ±10% UPS Output Voltage (3 phase, 3/4 wire + ground)

Frequency: 60Hz (±0.25Hz up to 2Hz)

Output

Voltage: 480 or 600Vac, ±3%, 3 Phase, 3 or 4 wire + ground

Power Factor: 0.9 at nominal kVA/up to unity at rated nominal kW

Frequency:60Hz + 0.1% free running synchronized with bypass (selectable in 0.25Hz increments)

Voltage regulation: ±0.5% steady state

Voltage recovery Time: ±1% of the steady state value within 1 cycle

Voltage Distortion: 2% L-L (4% L-N) THDI max

inverter overload: 125% for 10min, 150% for 1min

unbalanced load:Up to 100% 120° ±3% maximum angle displacement, ±3% maximum voltage deviation

ePS 7000

300kVA/270kW 400kVA/360kW 500kVA/450kW 300kVA/270kW 400kVA/360kW 500kVA/450kW

input/output Voltage: 480/480V 480/480V 480/480V 600/600V 600/600V 600/600V

nominal input current: 371A 508A 656A 322A 441A 569A

Maximum input current: 543A 688A 840A 466A 586A 711A

nominal bypass current: 361A 481A 601A 289A 385A 481A

uPS output current: 361A 481A 601A 289A 385A 481A

input cb Trip/Frame Size: 1000/1200A 1000/1200A 1000/1200A 1000/1200A 1000/1200A 1000/1200A

Maintenance bypass Trip / Frame Size (a):

800/1200A 800/1200A 800/1200A 700/1200A 700/1200A 700/1200A

Dc current (Max): 721 962 1195 721 962 1195

Dc breaker Trip/ Frame Size (a):

700/1200A 1000/1200A 1200/1200A 700/1200A 1000/1200A 1200/1200A

System efficiency: 94% 94% 93% 94% 94% 93%

Full load Heat rejection (bTus):

59400 78100 110750 65000 86000 112000

EPS 7000

Su

rge

Pro

tec

tio

n

64

65

Su

rge S

up

pressio

n

AlphaTVSS™

Transient Voltage Surge Suppression

> Safe operation – no explosions, no smoke, no fumes and no flames

> Isolates the load from damaging transients and other abnormal line conditions

> Lifetime of 20+ years

> NEMA 4X rated enclosure

> UL recognized surge suppression component (UL 1449 2nd edition Feb. 2007)

The Strikesorb™ surge suppression module incorporates state-of-the-art developments in metal oxide

technology to provide superior protection throughout its long service life. It has been designed to

withstand repeated surges, providing cost-effective and maintenance-free operation in harsh

environments. Strikesorb is the only UL (1449 – 2nd edition) recognized surge protection module rated for

safe operation without the use of additional internal fuses. This technology, combined with the capability

to be connected directly on the power lines (feed-through connection) make Strikesorb the most reliable

surge protection device available.

alphaTVSS

Models ATVSS-2-120 ATVSS-3-120/240 ATVSS-4-120/208 ATVSS-2-240 ATVSS-4-220/380

Electrical Characteristics

nominal operation Voltage: 120V 120V/240V 120V/208V 240V 220V/380V

Maximum continuous operating Voltage:

150V 150V 150V 300V 480V

Vref (Peak) @ 5ma ac (Peak): 263V 263V 263V 526V 833V

operating Frequency range: 25 to 500Hz 25 to 500Hz 25 to 500Hz 25 to 500Hz 25 to 500Hz

leakage current at Vn: 0.30mA 0.30mA 0.30mA 0.35mA 0.45mA

Surge Protection Levels

Surge Voltage rating: 500V 500V 500V 800V 1500V

response Time: <1ns <1ns <1ns <1ns <1ns

Maximum Surge current: 140kA 140kA 140kA 140kA 140kA

Maximum lightning current: 7.5kA 7.5kA 7.5kA 7.5kA 7.5kA

Let through Voltage

For Surge current 10ka (8/20): 435V 435V 435V 895V 1355V

Enclosure IP65-NEMA4 IP65-NEMA4 IP65-NEMA4 IP65-NEMA4 IP65-NEMA4

Dimensions (in/mm):6 x 8 x 6 / 152 x 203 x 152

10 x 12 x 6 / 254 x 305 x 152

10 x 12 x 6 / 254 x 305 x 152

6 x 8 x 6 / 152 x 203 x 152

10 x 12 x 6 / 254 x 305 x 152

operating Temperature: -40 to 85°C / -40 to 185°F

large Thermal capacity electrodes:Absorb heat generated during surges and decelerate MOV ageing

Strong aluminum Housing:Prevents explosions

1500+ Pounds of Pressure:Results in very low dynamic resistance

no Fuel to burn:Prevents fire and smoke emission

Single, Distribution-grade Varistor:Contributes to reliability, long lifetime, avoiding parallel connected MOVs

Coaxial symmetry and uniform surge current distributionStrikesorb Module

66

Alp

ha

Tech

no

log

ies

Ser

vice

s

67

Alp

ha Tech

no

log

ies Services

> Turn-Key Installation Alpha’s complete power system integration and turn-key installation services include right-of-way and

easement procurement, site preparation, equipment installation, utility hookup coordination, system

turn-up and system testing.

• Alpha performs all site negotiations

• Alphacoordinatesutilitiesandconstructionpermittingprocess

• CorrectinstallationandmaintenanceofHeadend,DCPlantandOutsidePlantpowersolutions

• CustomersbenefitfromAlpha’sprofessionalprojectmanagementandqualitycontrol

> Turn-Up and Test Services Turn-up and test services for Headend, DC Plant and Outside Plant installations performed by Alpha

specialists represent a significant first step in ensuring long-term system reliability. Services include

verification of proper installation, completion of Alpha start-up procedures and system testing.

• Turn-up and test completed by Alpha technicians

• Certifiedinstallationinspections

• Coordinatedproductandserviceordering,trackingandbilling

• Extendedwarrantyavailability

• Allowscustomerstofocusonfiberandtransmissionequipment

> Field Service Calls Trained Alpha field service engineers are dispatched 24 hours per day, 7 days per week in

specially equipped and stocked Alpha service vehicles to perform routine system

maintenance or emergency repair service.

> Preventative Maintenance An on-going preventative maintenance program helps ensure optimum system reliability and equipment

life. Alpha’s service plan options include performing routine scheduled maintenance, testing of local and

remote alarm operation, and analyzing local data for special requirements. Local service logs are

updated and information is uploaded to Alpha’s central database.

• Develophistorical data file for each power system component

• Completepreventativemaintenancechecklists

• Performmechanicalmaintenance

• Checkaccuracyofmonitoringsystemreadoutsandalarmsetpoints

• Documentroutine service or callouts

> Alpha Depot Repair Services Alpha’s repair depots are located across the country to easily serve our customers. Alpha’s repair and

development laboratories are designed for product repair and refurbishment, product improvement,

research and modification, to assist with our customer’s specific needs.

• Warranty and non-warranty repair

• CompleterepairandrefurbishmentofallAlphaproductlines

• EasyonlineRMAprocess(withlinktoonlinepart)

• RepairofnonAlphaproductsfor:cable,headend,fiberoptics,linegear,powersupplies and test equipment

• Onsitecalibrationandrepairoftestequipment

• Alphacertifiedtechnicians

• Multiplelocations:Bellingham,Washington;Suwanee,Georgia;andGarland,Texas

Alpha Technologies Services

68

Alp

ha Tech

no

log

ies Services

69

Fib

er Po

wer S

ystems

FTTx PowerAlpha Technologies offers a complete portfolio of fiber-to-the-home powering options with the

FlexPoint™ line of 12Vdc single-family solutions (SFU) and the FlexNet™ line of 48Vdc multiple dwelling

(MDU) and small office home office (SOHO) power supplies.

> FlexPoint 1230 Series The FlexPoint 1230, 30W, 12Vdc standby power supply is an environmentally hardened standby power

supply intended to be placed in indoor or outdoor sheltered locations providing the service provider

flexibility in locating the product. The FP1230 is compact allowing placement in the most densely

populated structured media enclosures. The FP1230 includes a unique emergency battery reserve

function that provides greater lifeline service availability by preserving 25% of the usable battery

capacity for user initiated emergency telephone calls.

> FlexPoint AX Series Alpha’s FlexPoint AX Series fiber-to-the-premises optical network terminal (ONT) power supply system,

provides network operators a highly reliable, scalable set of solutions for full or partial outdoor

installations. This system provides service technicians 24/7 access to the power system FlexPoint AX

home converters and power ring converters provide 12Vdc support for indoor and outdoor

applications not requiring standby power. As voice or critical data services are subscribed 7.2 or 17Ah

battery backup power supplies (BBPS) can be easily added.

> FlexNet FMPS The FTTx Multipurpose Power Supply (FMPS) is an outdoor or indoor system providing 150W of 48Vdc

power to MDU and SOHO optical network terminals. The FlexNet FMPS is an environmentally

hardened wall mount enclosure system with dual ONT connections supported with one or two 48Vdc

strings of 7.2Ah batteries. The system includes one or two parallel outputs and alarm connections,

supporting distances of up to 100ft between the FMPS and ONT, allowing the FMPS to be located

close to existing power outlets.

> FlexNet FiberUPS The FlexNet FiberUPS is a 300W, 48Vdc battery backup power module supporting a variety of indoor

and outdoor applications. Installed in pole, wall or ground mount rainproof enclosures along with

Alpha’s 85GXL 50Ah batteries, the FlexNet FiberUPS will keep field distributed electronics up and

running during power disturbances and outages.

> FlexNet PMR and GMR Series The FlexNet PMR and GMR series is comprised of two sizes of pole mount and two sizes of ground

mount factory configured and regulatory certified rainproof enclosure systems. PMR and GMR are

highlyconfigurablesystemsincluding19"adjustableorpulloutswingracks,ACserviceentranceand

distribution, surge suppression, fiber management, power bypass cabling, FiberUPS DC power

supply, DC distribution and 50Ah AlphaCell™ batteries.

> Radium MiniBay™ Series The Radium MiniBay is a highly configurable enclosure system supporting a wide range of applications

including bulk power, hub, secondary hub and remote terminal. Also ideal for remote optical transition

applications including optical amplification, downstream DWDM demultiplexing, narrowcast combining

and return path aggregation providing services to remote communities. The Radium MiniBay is

configured to order.

70

Fib

er P

ow

er S

yste

ms

FlexPoint™ 1230 SeriesIndoor 12Vdc 30W UPS

> Telecommunications grade power system provides 30W of 12Vdc primary and standby power for FTTx actives

> Easy customer replaceable hot swappable 7.2 or optional 12Ah battery

> Emergency battery reserve for greater E911 availability

> Battery management system engineered to provide optimum service life and runtime

> Coax F-Style packet cable interface options

FlexPoint 1230 Series

Models Description

FP-1230-01-a: 120Vac US Domestic 3-conductor power cord (NEMA 5-15)

FP-1230F-01-a: 120Vac US Domestic 3-conductor power cord (NEMA 5-15) F-connector output

Input OPS

ac input Voltage: 120Vac or 240Vac

ac input Frequency: 50/60Hz

Surge Protection:ANSI/IEEE Std. C62.41 to Category A, B, orCrequirements,usinga“RingWave”or“Combination”waveform,atalevelof6kV

Output

operational output Power:30W max continuous (ONT load + battery charge + heater*)

output Voltage: 12Vdc Nominal (Battery voltage upon loss of AC)

output Power loading:Following GR-909 telephone lines in various states, e.g., ringing, off-hook, on-hook, data, and video operation requirements

auxiliary input Voltage: 10.5 to 20Vdc

Physical

Housing Size (in/cm): 8.75 x 7.75 x 3 / 22.4 x 17.7 x 7.62

weight (lb/kg): 3 / 1.4

battery 7.2ah (lb/kg): 5.7 / 2.6

battery 12ah (lb/kg): 8.4 / 3.8

Battery

battery Type: Maintenance free, leak-proof, sealed VRLA (valve regulated lead acid)

Visual Indicators

System: Green LEDPower is available at the output (AC, battery or auxiliary)

battery: Green LEDBattery discharging to 25% SOC (main or auxiliary)

Green FlashAt 40% SOC (main battery) the indicator begins to flash

replace battery: Red LED Battery not present or failed self test

auxiliary Power Source: Green LED Valid auxiliary power source connected

Audible Status Indicators

loss of input Power: Single, one second chirp

low battery: Single chirp every 15 seconds at 40% SOC

replace battery: Double chirp spaced fifteen minutes apart

Push Buttons

Silence alarm: Suppresses the audible alarm for 24 hours

battery emergency use: Accesses reserve battery capacity

Standards

System:FCC part 15 Class B, CSA-NRTL\C (CSA60950), CE, C-Tic, RoHS to EU 2002/95/EC, Seismic Zone 4 rated per GR-63

Environmental

Storage Temperature: -40 to 55°C / -40 to 127°F

operating Temp w/out Heater: -20 to 55°C / -4 to 127°F

operating Temp w/ Heater: -30 to 55°C / -22 to 127°F

Note:OperatingtemperaturesbasedonAX-LONGBAT-7.

Humidity: 0 to 95%

operating elevation Max: 3000m / 10000ft Derate at 2°C per 1000ft above 6000ft

Storage elevation Max: 15000m / 50000ft

Interface

Dc output and alarm:Removable Screw Terminal Plug accepts seven (2) 16AWG and (7) 24AWG wires

auxiliary Dc input:3.5mm (OD), 1.3mm (Pin, positive) coaxial barrel connector

ac input: IEC320/C6 Receptacle

line cord:NEMA 1 to 15 to IEC 320 C5 (Other cords available upon request)

Warranty

FlexPoint 1230: 3 years repair or replace

batteries available: 1 year or 3 year

Supporting Options

aX-STDbaT-7 — Battery 7.2AH AGM, 1 year warrantyaX-longbaT-7 — Battery 7.2AH AGM, 3 year warrantyaX-STDbaT-12 — Battery 12AH AGM, 1 year warrantyFP1230-cVr — FlexPoint 1230 12AH battery cover with strapFP1230-HK — FlexPoint 1230 heater kitFTTH-cbl — ONT hook-up cable, 2x16AWG and 5x24AWG, CMX UL listedauX-cbl — Cable, auxiliary power plug 3m long

FlexPoint 1230 shown with cover removed, battery, auxiliary power cable

and ONT hook-up cable

FlexPoint 1230 withCoax F-Style Interface

FlexPoint 1230 connector interface and cable strain relief

FlexPoint 1230

71

Fib

er Po

wer S

ystems

FlexPoint™ aX SeriesOutdoor/Indoor 12Vdc 30W UPS

> Scalable FTTP/FTTx power supply systems with and without standby

> Full or partial outdoor configurations

> Outdoor rated including battery for 24/7 availability

> Utility meter base provides most reliable source of AC power at home

> No homeowner appointments needed for access

> Safe, low-voltage distribution

> 30W with battery module, 24W without battery module

FlexPoint aX Series

Input

ac input Voltage (aX30-12D-Hc): 85 to 132Vac (120Vac Nominal)

ac input Voltage (aX-30-12D-Pc): 170 to 264Vac (230Vac Nominal)

ac input Frequency: 50 to 60Hz

Note:International AC selections and line cords available.

Output

DC Output Voltage

Pc/Hc + bbPS (uPS System): 10.5 to 14.4Vdc

Pc/Hc (non uPS): 11.6Vdc

Continuous Output Power

Pc/Hc + bbPS (uPS System): 30W at nominal battery float voltage

Pc/Hc (non uPS): 24W

Max output Power (uPS System): (<10s) 45W

Max output Power (non uPS): 2.4A current limit (HC/PC)

Short circuit Protection: Electronic

Dc ripple: 150mV

Environmental

Operating Temperature Range

aX-30-12D-Pc + bbPS: -40 to 65°C / -40 to 149°F

aX-30-12D-Hc + bbPS:HC:-40to45°C/-40to113°F, BBPS:-40to65°C/-40to149°F

aX-30-12D-Hc: -40 to 45°C / -40 to 113°F

Humidity: 0 to 95%

battery Storage: -15 to 65°C / 5 to 149°F, 0 to 95% humidity

operating elevation Max: 3000m / 10000ft

Storage elevation Max: 15000m / 50000ft

FlexPoint UPS Runtimes (minutes) over Temperature

7.2Ah

load/Temp. -40°c/-40°F -20°c/-4°F 25°c/77°F

7w 360 560 800

10w 160 360 500

15w 110 195 320

18w 80 156 240

20w 60 130 210

25w 50 100 170

30w 30 80 130

Battery

Type:Maintenance-free, leak-proof, sealed VRLA (valve regulated lead acid)

recharge Time:AX-12D-BBPS-7.2:<16hrswith24W

AX-12D-BBPS-17 load <36hrs with 24W load

Regulatory Approvals

Home converter: UL-Listed System, FCC Part 15, Class B, EN55022, Class B

Power ring: UL-Recognized Components

Power ring converter: UL-Recognized Components

bbPS Modules: CSA

Warranty

electronics: 2 years

battery–Standard: 1 years

battery–long life: 3 years

Status Alarms

Local (LED Indicators)

green Steady Output OK

green blinking Standby Operation

red Steady Replace Battery

red blinking Battery Missing/Battery Low

Remote (Status Alarms – PacketCable Compliant)

ac Fail Output Power drawn from battery

replace battery Battery has failed periodic self-test

battery Missing Battery is disconnected

battery low Battery has 20% remaining runtime

FlexPoint UPS Runtimes (minutes) over Temperature

17Ah

load/Temp. -40°c/-40°F 20°c/-4°F 25°c/77°F

10w 750 1080 1240

15w 400 680 940

20w 60 440 680

25w 160 340 480

30w 140 232 400

FlexPoint PowerRing converter with 7.2Ah Battery Enclosure

72

Fib

er P

ow

er S

yste

ms

FlexPoint™ aX SeriesOutdoor/Indoor 12Vdc 30W UPS

Module Descriptions

Power-Ring

Compatible with ring and ringless style meter sockets it provides a receiving socket for the FlexPoint AC to DC Power-Ring Converter module. Depending on the model the Power-Ring can tap the AC power before or after the meter and comes supplied with a blanking plate.

Models: 200A Continuous, 240A RatedAX-POWER-RING-A (power tap after meter) —P/N 021-053-21AX-POWER-RING-B (power tap before meter) — P/N 021-053-20

320A Continuous, 400A RatedAX-400ARING-A (power tap after meter) — P/N 021-053-30 AX-400ARING-B (power tap before meter) — P/N 021-053-31

Dimensions (in/mm): 4.75H x 7Dia / 120H x 178Dia

weight (lb/kg): 1.5 / 0.68

Power-Ring Converter

Contains highly-reliable environmentally-hardened 240Vac to 12Vdc converter circuitry in a pluggable housing. Outputs 24W and 11.6Vdc as a stand-alone module, or supports 30W and 11.6 to 16Vdc battery backup power supply (BBPS) module output

Model: AX30-12D-PC — P/N 010-318-31

Dimensions (in/mm): 8 x 2 x 2 / 209 x 51 x 51

weight (lb/kg): 0.7 / 0.32

Home Converter

Contains highly-reliable environmentally-hardened 120Vac to 12Vdc converter circuitry in a wall mount housing. Comes with a two-conductor AC line cord and should be mounted in locations sheltered from rain or snow. Outputs 24W and 11.6Vdc as a stand-alone module or supports 30W and 11.6 to 16Vdc battery backup power supply (BBPS) module output.

Model: AX30-12D-HC — P/N 010-318-37

Dimensions (in/mm): 8.25 x 2.75 x 1.5 / 209 x 70 x 38

weight (lb/kg): 0.7 / 0.32

The UPS Modules

Provides the Network Operator the capability to place the battery management element inside other enclosures located at the subscriber’s home. UPS modules contain the same electronics used in the AX-12D-BBPS products without the battery heater and are to be used with FlexPoint Home Converter and Power-Ring Converter.

Models: AX-12D-7.2Ah (for 7.2Ah battery) — P/N 745-816-21

AX-12D-17Ah (for 17Ah battery) — P/N 745-816-20

Module Descriptions

Battery Modules

The Battery Backup Power Supply (BBPS) module outputs 30W of continuous power and includes a microprocessor-based battery charge management system providing the correct charge voltage to the battery over a wide temperature range, while performing periodic battery capacity testing and status reporting to the ONT and customer. The onboard battery heater provides extended standby runtimes in cold conditions to -40°C. The 7.2Ah battery model provides standard runtimes and the 17Ah model provides extended runtimes.

Models: AX-12D-BBPS-7.2 — P/N 031-264-20

Dimensions (in/mm): 8 x 9 x 4 / 203 x 230 x 102

weight (lb/kg): 1.5 / .68

AX-12D-BBPS-17 — P/N 031-192-30

Dimensions (in/mm): 14 x 9.5 x 5 / 355 x 241 x 127

weight (lb/kg): 4.5 / 2.04

Batteries

The FlexPoint AX battery modules use maintenance-free sealed-lead acid.

Models: AX-STDBAT-7 — P/N 181-036-10Standard-Life 7.2AH AGM Battery, 1-year Warranty

AX-LONGBAT-7 — P/N 181-063-10Long-Life 7.2AH AGM Battery, 3-year Warranty

weight (lb/kg): 5 / 2.27

AX-STDBAT-17 — P/N 181-022-10Standard Life 17AH AGM Battery, 1-year Warranty

weight (lb/kg): 13 / 5.9

73

Fib

er Po

wer S

ystems

FlexPoint™ aX SeriesOutdoor/Indoor 12Vdc 30W UPS

Applications

Indoor Powering – Non-UPS

OperationalTemperatureRange:-40to45°C/-40to113°F

11.6Vdc Nominal

Indoor Powering – UPS

OperationalTemperatureIndoorRange:-40to45°C/-40to113°FOperationalTemperatureOutdoorRange:-40to65°C/-40to149°F

Outdoor Powering – Non-UPS

OperationalTemperatureRange:-40to65°C/-40to149°F

Outdoor Powering – UPS

OperationalTemperatureRange:-40to65°C/-40to149°F

74

Fib

er P

ow

er S

yste

ms

Flexnet™ FMPSOutdoor 48Vdc 150W UPS

> Fiber-to-the-Premise UPS for Multiple Dwelling, Multiple Tenant and Small Business Unit applications

> Supports one or two MDU/SBU ONTs located up to 100ft from FMPS

> Battery management performs periodic battery capacity testing and status reporting to the ONT and customer

> Battery heater option provides extended runtime for applications in cold weather conditions

> Hybrid 16AWG and alarm cable minimizes installation labor

> Status indicators and audible alarm provide local status

Flexnet FMPS

Input

ac input Voltage: 90 to 320Vac

ac input Frequency: 45 to 66Hz

Surge Protection: ANSI/IEEE Std. C62.41 to Category A, B, or C requirements,usinga“RingWave”or“Combination”waveform, at a level of 6kV

Output

operational output Power: 150W continuous to 170W, 10sec max

output Voltage: 48 to 58Vdc w/AC power, 42 to 58Vdc with battery

output current: 3.1A typical (crowbar limited beyond 5A DC)

output Power loading:Following GR-909 telephone lines in various states, e.g., ringing, off-hook, on-hook, data, and video operation requirements.

ripple: Less than 3mVrms

noise: Less than 100mVp-p

output connection:Two terminal blocks accepting 16AWG, parallel connections

Local Alarms

System leD: Green Steady = System Output Normal, DC OutputOff = No AC or Battery Power

battery leD: Yellow Steady = System on BatteryOff = Normal Mode

replace battery:Red Steady = Replace One or Two Battery StringsOff = Batteries Within Parameters

replace battery a and b (internal):

Steady Red = Replace One or Both Battery StringsOff = Batteries Within Parameters

Remote Alarms

connection: Two five position IDC 24AWG, parallel connections

Pin 1 alarm return: Open collector return reference

Pin 2 ac Fail: On battery

Pin 3 replace battery: One or both battery strings failed periodic self test

Pin 4 Missing battery: Less than eight batteries

Pin 5 battery low: Battery string voltage is less than 46.8Vdc

Local - Audible Indicator

alarm on:“AlarmEnable/Disable”toggleswitchlocatedonUPS Batteries Below Voltage Parameters

Mechanical

FMPS

Dimensions(in/mm): 14 x 23.75 x 5.5 / 355.6 x 603.3 x 139.7

Weight(lb/kg): 25 / 11.3

FMPS + Shipping Carton

Dimensions(in/mm): 17 x 28.5 x 11.75 / 431.8 x 723.9 x 298.5

Weight(lb/kg): 30 / 13.6

Battery

BatteryType:Four or eight 7.2Ah Valve Regulated Lead Acid (VRLA) (Batteries sold separately)

Environmental

operating (with heater option): -40 to 46°C / -40 to 115°F plus solar loading, 0 to 95%

(without heater option):-10 to 46°C / 14 to 115°F plus solar loading, 0 to 95% humidity, 0 to 3000m / 0 to 10000ft elevation

Storage:-15 to 85°C / -5 to 185°F, 0 to 95% humidity, 0 to 15000m / 0 to 50000ft elevation

Standards

CSA/UL 60950, EN 60950, EN 55022 Class B, FCC Part 15 Class B, GR 63 Sect 4.2 Fire Resistance, GR-1089 Sect 3 Emissions, Sect 4 Lightning and AC Power Fault, Sect 7 Electrical Safety

Warranty

3 year repair or replace

FMPS with cover removed and two 7.2Ah battery strings installed

FlexNet FMPS

75

Fib

er Po

wer S

ystems

Flexnet™ FiberuPSOutdoor/Indoor 48Vdc 300W UPS

> Power modules can be used in a variety of Alpha enclosures

> Rugged 48Vdc UPS for outdoor or indoor applications

> Temperature compensated battery charging for extended battery life

> Visual and electrical indicators for on-site and remote reporting

> Flexible cabinet mounting

Flexnet FiberuPS

Model ELPM 300 – 48D

Input

Voltage range: 85 to 170 or 132 to 264Vac (selectable)

Frequency: 50 or 60Hz

Output

Voltage: 48Vdc (42 to 54Vdc)

output Power Max: 300W

Transfer characteristics: Uninterrupted output

Dc ripple: 500mV

Battery

String Voltage: 48Vdc

Typical capacity: Four 50Ah (85GXL)

Type: Sealed lead acid GEL, maintenance free

battery charging: Temperature compensated

backup Time approx.: 8hrs @ 275W load

Mechanical

Dimensions (in/mm): 6 x 10.1 x 3.25 / 152 x 256.5 x 82.6

weight (lb/kg): 10 / 4.5

Mounting configuration: Bracket mounted inside enclosure

Environmental

operating Temperature: -40 to 65°C / -40 to 149°F

Storage Temperature: -50 to 70°C / -58 to 158°F

Humidity: 0 to 95% non-condensing

LED Indicators

green: Output

green blinking: Standby

red blinking: Low/missing battery

red: Replace battery

Alarm Indicators

AC FAIL (TELM 1)Replace Battery (TELM 2)Battery Missing (TELM 3)Battery Low (TELM 4)

Note: Compliant with PacketCable™ UPS Specifications. Embedded MTA Primary Line Support Specification (PKT-SP-EMTA-Primary-101-001128)

Standards

FCC part 15 Class B CSA–NRTL\C (CSA950)

Standard Features

No audible noise Reverse battery polarity protection

Warranty

3 years repair or replace

FlexNet FiberUPS

FlexNet FiberUPS withMounting Hardware

76

Fib

er P

ow

er E

ncl

osu

res

PMR

GMR

PMr and gMr SeriesPole and Ground Mount Enclosures

> Supports field deployment of FTTx Optical Line Terminals (OLT)

> FlexNet™ 300W UPS provides over 10hrs of runtime

> Thermostatically controlled 48 or 120Vdc fan and heater options

>Adjustable19"EIAequipmentracks

> All aluminum construction, durable powdercoat finish, stainless steel hardware

PMr and gMr Series

Enclosure Weight and Dimensions

Models: PMr-S1 gMr-S1 PMr-S2 gMr-S2

Mounting: Pole Ground Pole Ground

Dimensions (in/mm):

26 x 32.2 x 19.2 / 660 x 818 x 489

27.5 x 31 x 20 / 699 x 787 x 508

30 x 37 x 19.25 / 762 x 940 x 489

31 x 38 x 20 / 787 x 965 x 508

weight (lb/kg): 40 / 18 49 / 22 47 / 21 63 / 29

Material: Powdercoated aluminum

Vent Screen (in/mm):

Stainless steel fabric with .005 x .005 / .12 x .12 opening size to minimize snow, water and dust ingress

Door and lid Seal:

Poron gasketing

Hardware: Stainless steel

color: Gray (Custom colors available)

Tamper Switch: Optional

Grounding

internal ground bar: Five usable lugs

Safety ground:AdjacenttoACoutlets (Optional stainless steel ground stud)

lid: Removable (PMR Series includes lanyard)

Door(s)

PMr Series: Hinged removable with stainless steel spring latch and door open prop rod

gMr Series: Removable lift-off front and rear door

Enclosure Mounting

PMr Series:Galvanized steel brackets for wood, and concrete Pole-mount and wall mount

gMr Series:Precast polymer concrete pad or PS-6/PS-6XL pedestal systems

Thermal Management

cooling: 120Vac and 48Vdc fan options

Heating: 120Vac and 48Vdc heater options

Internal Mounting Rails

rackmounting: EIA 19" mounting rails using Tinnerman mounting clips

grounding: Rails grounded to chassis

adjustment: 1" increments over 6" when batteries are not installed.

Enclosure Environmental Rating

equipment Mounting area:

Designed to IP X5 per IEC 529 Dust Ingress controlled by screen opening IP X5 applies to the equipment mounting area The service entrance is rated 3R

Fiber Management Options

Fiber Strain relief Tie bar (optional):

19" mounting provides ability to strain relief fiber cable plugged into the front of communications equipment

Splice Tray (optional):

Splice Tray Kit (12 count), includes Splice tray with Elastomer Splice Block, Felt Tape, Tie Wraps, Cover and Recording Label

Fiber Management Panel (optional):

Provides fiber slack storage and secures a splice tray using a Velcro strap. Tie wrap slots on sides permit securing fiber cables to panel

Power Supply and Batteries

Model:

FlexNet300-48/48Vdc UPS Power Supply Module - including 60" output power cable, remote temp sensor, wall mounting brackets and alarm output connector

batteries:48Vdc string of 85 GXL (50Ah) positioned on ends (negative terminal side down) with battery retaining bar option

battery cable Kit: Fused

battery Heater: Optional

ac Service:External 70A rainproof SUSE rated breaker box with internal 120Vac 20A receptacles

regulatory: CSA-NRTL/C (CSA 60950)Notes: 1. Additional rack space capacity if batteries are not installed2. Runtime of 10hrs based on 212W load and new batteries discharged to 1.75VPC at 25°C/77°F

Shown with FTTX actives installed

77

Fib

er Po

wer E

nclo

sures

radium Minibay™

Environmentally Controlled Enclosures

> Highly configurable, scalable, environmentally controlled enclosure system

> Factory integrated power with agency certification

> Ideal for remote optical transition applications

> High reliability 24 or 48Vdc high efficiency air conditioner

> Natural gas or propane DC generator system for indefinite operation in emergency conditions

> Powdercoated aluminum construction for long life

> Installation and service programs available

The Radium MiniBay is a modular, highly configurable Telecom

grade enclosure system including fully scalable power to 4,000W

and 1240Ah of battery capacity with ample rack space for

communications electronics. The MiniBay system benefits from

more than 30 years of Alpha’s Outside Plant (OSP) powering

experience. The MiniBay integrates Alpha’s comprehensive line of

power solutions for today’s complex Hub and environmentally

controlled enclosure requirements including Alpha’s AC UPS,

Cordex™ rectifiers, and the AlphaGen™ series of telephony grade

DC generators. Features for the Radium MiniBay include: front and

rear accessible 19" or 23" equipment racks providing up to 46

rackmount spaces, durable powdercoated aluminum construction,

battery storage modules isolated from the equipment section each

supporting up to four 155Ah batteries for a 19A load for 8hrs.

Typical CSA-NRTL marked configurations include integrated AC

service entrance, surge protection, AC distribution, DC distribution,

standby generator interface, heat exchanger, fan/filter or air

conditioner thermal management, rectifiers or AC UPS equipment.

Standards

environmental rating:

NEMA 3R when configured with door mounted fans and filter system. Designed to meet IP55 when configured with heat exchanger or air conditioning system.

Seismic rating:Consult factory. A seismic rating is based on a set system configuration with defined mounting locations and equipment types.

Design Standards:Following NEC and Telcordia Technologies (Bellcore) GR-487, GR-63 and GR-108 guidelines.

compliance:Third party approval from National Recognized Testing Laboratory (NRTL).

Material: High strength corrosion resistant aluminum

Finish: Almond color powdercoat finish

Weight and Dimensions

weight (lb/kg): Dimensions (in/cm):

equipment enclosure: 195 / 88.5 32 x 44 x 30 / 81.3 x 106.7 x 76.2

battery Storage Module: 130 / 59 32 x 14 x 30 / 81.3 x 35.6 x 76.2

riser Module: 102 / 46.3 32 x 14 x 30 / 81.3 x 35.6 x 76.2

Side chamber Sc1: 100 / 45.4 12 x 72 x 32 / 30.5 x 81.3 x 131.1

Side chamber Sc2: 89 / 40.4 12 x 72 x 32 / 30.5 x 81.3 x 131.1

Fans and Filters

The most basic thermal management system supporting the MiniBay utilizes conformal-coated, variable speed and alarm monitored 48Vdc fans with electrostatic air filters. This configuration has a NEMA 3R rating.•48Vdcfansprovideupto1000Wthermaldissipationwitha15°C/59°Frise over ambient with 32W maximum power draw•VariablespeedcontrolledDCfanscontinuetooperateduringautilityoutage•Conformal-coatedfans•Electrostaticandwashableairfilters•Fieldreplaceablefans•FormCdrycontactalarmreportfanfail,openonalarm•ACsystemsavailable•ACthermalmanagementoptionsavailable

Heat Exchanger

An airtight rear door and a heat exchanger equipped hinged front door. This configuration is designed to meet the IP55 standard and has a NEMA 3R rating.•Coolingcapacityof690Wdissipatedwith15°C/59°Friseoverambientwitha maximum power draw 120W.•Variablespeedfantemperaturecontrolandlowvoltagedisconnect.Fans turn off below 23°C Fans turn on at 25°C and run from 25% to 100% with increased enclosure temperature from 25 to 45°C / 77 to 113°F.•FormCdrycontactalarms(Minor:Fanfail,openonalarmandMajor: Enclosure over-temp fixed at 60°C/140°F, open on alarm). •Variablespeed48Vdcfanscontinuetooperateduringautilityoutage•Fieldreplaceablefans•ACheatexchangesavailable

DC Air Conditioner

The MiniBay is supported by 48Vdc or 24Vdc variable speed highly efficient variable speed air conditioner systems for applications requiring reliable below ambient cooling and dehumidifying support with seamless performance through extended utility outages.•Coolingcapacityof878Wdissipatedat43°C/109°Foutdoorambientand maximum internal ambient temperature of 40°C/104°F.•Variablespeedbrushlessmotorcompressortemperaturecontrolandlow voltage disconnect•Adjustableenclosuretemperaturesetpoints•FormCdrycontactalarms(Minor:Highcondensingtempand/orenclosure over-temp,openonalarmandMajor:coolingsystemfailed,openonalarm).•Maximumpowerdraw500W.

MiniBay with Fiber Management

Rack space for customer supplied equipment

RSM 48/10 Rectifiers with distribution

Battery drawer

48Vdc air conditioner

Radium MiniBay

78

Fib

er Po

wer E

nclo

sures

79

DC

Po

wer E

nclo

sures

Alpha EnclosuresTempest brings convenience, strength and versatility to outdoor power system enclosures. The fully

integrated modular design combines AC, DC and backup battery power into one space. All are

designed to serve ASDL, TI and fiber optic transmission system (FOTS) facility applications.

> Tempest Te25 SeriesThe Te25 is designed to meet the requirements for service providers with remote outdoor or

secure indoor applications. Welded aluminum construction provides structural integrity that

will withstand seismic events and harsh weather conditions.

> Tempest Te15The Tempest Te15’s compact footprint is an ideal, economical solution for microwave, fiber and E911

applications. The optional integrated solar shield, heater, and air conditioner protect the batteries and

equipment from severe environmental conditions. Fully secure pad-lockable doors and intrusion

alarms keep equipment safe and secure.

> Tempest Te17Tempest brings convenience and versatility to outdoor power system enclosures. In addition to ADSL,

TI and fiber optic transmission system (FOTS) facility applications, the Te17 is designed to meet the

requirements of WiMax service providers.

> Tempest Te20 SeriesMore battery power in a compact cabinet. The Tempest Te20 Series is an innovative environmentally

controlled outdoor enclosure system that provides maximum backup power. Service providers will

save money and valuable lease space with this cabinet’s ability to house up to 20 batteries in a single,

secure cabinet solution.

> Tempest Te21The Tempest Te21’s compact footprint is an ideal, economical solution for microwave, fiber and E911

applications. Lower compartment air conditioning protects the batteries and customer equipment from

severe environmental conditions. Upper compartment fan cooling provides adequate cooling for

65˚C/149˚F temperature hardened power systems.

80

DC

Po

wer

En

clo

sure

s

Tempest Te25 / Te25xhOutdoor System Enclosure

> Designed for outdoor or secure indoor applications

> Easily transportable

> Durable aluminum construction

> Pedestal, wall, pole or rackmount

> Compact footprint

Tempest Te25 / Te25xh

Electrical

Contact Alpha for AC load center options for specific equipment requirements

Mechanical

Te25 cabinet Dimensions (in/mm):

20.3 x 21.4 x 20.4 / 516 x 544 x 518

Te25 weight (lb/kg): 65 / 29 approx without customer equipment

Te25xh cabinet Dimensions (in/mm):

36 x 21.4 x 20.4 / 914 x 544 x 518

Te25xh weight (lb/kg): 90/41 approx. without customer equipment

options:

Wall mount Pole mount Pedestal mount Rackmount AC distribution Meter base Generator connector and transfer switch GMT fuse block Surge arrestor

Dc connections: Multiple connection

chassis ground: Multiple connection Buss bar located in cabinet

Security: Lockable front door

Alarm

connection: Terminal block

Description: Intrusion

Tempest Te25xh

Standards

cSa:C22.2 No 60950-01-03Std. No 60950-01 NEMA Type 3R (CSA C22.2 No 94-M91)

Seismic: Designed to meet Zone 4 requirements

Related Components

Heating and cooling: Optional DC fan cooling option (standard design is vented with filters)

Tempest Te25 (with batteries)

Tempest Te25xh (open)

Tempest Te25

81

DC

Po

wer E

nclo

sures

Tempest Te15Modular Enclosure

> Modular design for single or multiple

> Cabinet configurations

> Welded aluminum construction

> 39RU of rack space

> Heating and cooling options

> Compact footprint

Tempest Te15

Electrical

input Voltage:120/240Vac 200A single phase 120Vac 100A single phase

number of breakers: 18 maximum

Transfer Switch/generator connector:

Optional

TVSS: Optional

Mechanical

Top Compartment

Dimensions (in/mm): 8 x 32 x 32 / 203 x 813 x 813

Main Compartment

Dimensions (in/mm): 69 x 32 x 32 / 1753 x 813 x 813

Bottom Compartment

Dimensions (in/mm): 8 x 32 x 32 / 203 x 813 x 813

Solar Shield

Dimensions (in/mm): 2 x 32 x 32 / 76 x 813 x 813

Dc connections: Multiple connection

chassis ground: Multiple connection Buss bar located in cabinet

Security: Lockable front door

rack Space: 23" rails, 39RU

Alarm

connection: Terminal block

Description: High/Low Temperature Intrusion

Standards

cSa:C22.2 No 60950-01-03Std. No 60950-01 NEMA Type 3R (CSA C22.2 No 94-M91)

Seismic: Designed to meet Zone 4 requirements

Related Components

Heating and cooling: 600W

air conditioning: Up to 8000BTU

Fan cooling: Optional

Heat exchanger: Optional

Tempest Te15 (open)

Tempest Te15 Side mounted

AC distribution

82

DC

Po

wer

En

clo

sure

s

Tempest Te17Outdoor Enclosure

> Designed for outdoor network applications

> Easily transportable

> Durable welded aluminum construction

> Variety of configurations possible with 23RU of space

> Compact footprint

Tempest Te17

Electrical

Consult factory on AC load center options for specific equipment requirements

Mechanical

Main Compartment

Dimensions (in/mm): 43 x 30 x 28 / 1092 x 762 x 711

Bottom Compartment

Dimensions (in/mm): 14 x 30 x 28 / 356 x 762 x 711

Enclosure Assembly

Dimensions (in/mm): 58 x 30 x 28 / 1473 x 762 x 711

Solar Shield

Dimensions (in/mm): 1 x 30 x 28 / 25 x 762 x 711

rack units: 23" rack 23RU

weight (lb/kg): 450 / 204 (approx without customer equipment)

Dc connections: Multiple connection

chassis ground: Multiple connection Buss bar located in cabinet

Security: Lockable front door

Alarm

connection: Terminal block

Description: High/low temperature intrusion

Standards

cSa:C22.2 No 60950-01-03Std. No 60950-01 NEMA Type 3R (CSA C22.2 No 94-M91)

Seismic: Designed to meet Zone 4 requirements

Related Components

Heating and cooling:Contact factory on HVac options for specific environmental conditions

Tempest Te17 (shown configured to customer specification)

Tempest Te17 (shown with 5000BTU air conditioner,

bottom compartment, and solar shield)

83

DC

Po

wer E

nclo

sures

Tempest Te20Power Enclosure

> Available in 24 and 48Vdc, 1200A

> Designed for outdoor applications

> Air conditioned battery and customer equipment compartment

> Fan cooled DC power equipment compartment

> NEMA 3R rating

> Compatible with base mounting and cable interface

Tempest Te20Tempest Te20

Electrical

input Voltage:120/240Vac, connected direct to site AC distribution panel, option to mount external AC panel

Mechanical

Dimensions (in/mm):: 84 x 30 x 30 / 2137 x 762 x 762

weight (lb/kg): 828 / 379 (no batteries)

chassis ground: Multiple connection Buss bar located in cabinet

Security: Lockable front door

Dc Distribution:1 x 1200A 20 position bullet breaker, 4 x 600A load shedding capability

batteries: 3 shelves 4 battery/shelf

customer equipment: 7RU available

Alarm

connection: Terminal block

Description: High/low temperature intrusion

Cabinet Backup Capacity

number of batteries: 12

battery amp Hour: 150Ah each

runtime (@ 25 to 175°c / 77 to 347°F VPc 24V)

20 min: 1246A

2 hrs: 332A

4 hrs: 185A

Standards

Safety:C22.2 No 60950-01-03Std. No 60950-01 NEMA Type 3R (CSA C22.2 No 94-M91)

Seismic: Designed to meet Zone 4 requirements

Related Components

Heater: 600W (optional)

air conditioning: Up to 58000BTU

Fan cooling: Power component

Tempest Te20

84

DC

Po

wer

En

clo

sure

s

Tempest Te20bBattery Enclosure

> 10 strings @ 24Vdc, 5 strings @ 48Vdc

> 1200A Bus

> Designed for outdoor network applications

> Optimum backup power source

> Environmentally controlled

> Compact footprint

Tempest Te20b

Electrical

input Voltage: 120 or 240Vac single phase (air conditioner)

output Voltage: Battery cabinet, 24 or 48Vdc

recommended Feeder breaker: 15A time delay breaker

Mechanical

Cabinet

Dimensions (in/mm): 84 x 30 x 30 / 2137 x 762 x 762

weight (lb/kg): 700 / 318

Enclosure: Aluminium shell, Steel internal battery shelving

Battery Shelf Dimensions

Dimensions (in/mm):: 11.8 x 21.6 x 21.5 / 300 x 549 x 546

Dc connections: Multiple connection

chassis ground: Multiple connection Buss bar located in cabinet

Security: Lockable front door

Environmental

outdoor Temperature: -40 to 46˚C / -40 to 115˚F

Alarm

connection: Terminal block

Description:High/Low Temperature Intrusion

Standards

cSa:C22.2 No 60950-00Std. No 60950-2000NEMA 3R (UL50)

Seismic: Designed to meet Zone 4 requirements

Related Components

Heater: 600W

air conditioning: Up to 50000BTU

Tempest Te20b

Tempest Te20b (open)

85

DC

Po

wer E

nclo

sures

Tempest Te21Modular Enclosure

> Modular design for single or multiple cabinet configurations

> Welded aluminum construction

> Dual compartment system

> Compact footprint

> Up to 39.6kW @ 48V

> Multiple point cable access

Tempest Te21

Electrical

input Voltage:120/240Vac, connected direct to site AC distribution panel

Mechanical

Dimensions (in/mm): 84 x 30 x 30 / 2137 x 762 x 762

weight (lb/kg): 863 / 392 (no batteries)

chassis ground: Multiple connection Buss bar located in cabinet

Security: Lockable front door

Dc Distribution:2 x 1200A 20 position bullet breaker 4 x 600A load shedding capability

batteries: 2 shelves 4 battery/shelf

customer equipment: 8RU available

Alarm

connection: Terminal block

Description: High/low temperature intrusion

Standards

cSa:C22.2 No 60950-01-03Std. No 60950-01 NEMA Type 3R (CSA C22.2 No 94-M91)

Seismic: Designed to meet Zone 4 requirements

Related Components

Heater: 600W

air conditioning: Up to 58000BTU

Fan cooling: Optional

Tempest Te21

Tempest Te21 (open)

86

DC

Po

wer E

nclo

sures

87

Racks and Rack Accessories> SX Rack

The SX Rack is the next generation rack enclosure solution influenced by 10 years of customer

feedback, addressing current IT market trends for high-density server and networking applications.

With a strong focus on cooling, power distribution, cable management and environmental monitoring,

the SX Rack provides a reliable rackmounting environment for mission-critical equipment.

> 4 Post Open Frame Rack4 Post Open Frame Racks provide simple, low cost mounting for rackmount equipment in IT

environments. Ideal for rackmount servers, networking and telecom equipment where security at the

individual rack level is not required, open frame racks provide unobstructed airflow and fast, easy

access to installed equipment.

> Rack AccessoriesRack accessories include cable management, thermal management, shelving, keyboards, keyboard

drawers and stabilization accessories required for a complete enclosure solution.

> Rack HardwareMounting hardware includes light and heavy-duty shelves, bolt-down brackets, stabilization plates,

grounding kits, keyboard drawers, mounting rails, brackets and associated hardware.

Racks an

d R

ack Accesso

ries

88

SX 42ru rack19" and 23" Rack Enclosure

AR3150AR3100

> Tool free installation and removal of roof

>Rapidadjustmentoflevelingfeet

> Tool free PDU mounting provisions

> Numbered RU positions

> Light-weight, half-height side panels

> Tool free cable management options

> 42RU models roll through 2 meter doorways

> Cable openings for overhead or underfloor applications

SX 42ru rack

AR3100

weight (lb/kg): 275.2 / 125.09

Dimensions (in/mm):42.13 x 23.62 x 78.4 / 1070 x 600 x 1991

weight capacity - Static load (lb/kg): 3000 / 1363.6

weight capacity - Dynamic load (lb/kg): 2250 / 1022.7

SX 42ru rack

AR3150

weight (lb/kg): 343.10 / 155.95

Dimensions (in/mm):42.13 x 29.53 x 78.4 / 107 x 75 x 1991

weight capacity - Static load (lb/kg): 3000 / 1363.6

weight capacity - Dynamic load (lb/kg): 2250 / 1022.7

Rac

ks

Features

compatibility: Door ventilation exceeds 919 in2 (5933 cm2);CaptiveadjustmentofVerticalMountingRails;Fits-Like-A-Gloveguaranteedcompatibility

Safety: Integrated grounding; UBC Zone 4 stabilization provisions

Protection:Lockable doors and side panels; Door access monitoring; Static weight load rating of 3000lb; Serviceability; Quick release doors; Quick release side panels; Split rear doors

adaptability:Reversible doors; Scalable cooling options; Seamless integration of environmental monitoring devices; External baying for easy deployment in rows

89

SX 48ru rack19" and 23" Rack Enclosure

> Tool free installation and removal of roof

>Rapidadjustmentoflevelingfeet

> Tool free PDU mounting provisions

> Numbered RU positions

> Light-weight, half-height side panels

> Tool free cable management options

> 48RU models roll through 2 meter doorways

> Cable openings for overhead or underfloor applications

Enclosures providing cooling, power distribution, cable management and environmental monitoring for applications in IT environments.NetShelter®

SX is the next generation rack enclosure solution influenced by 10 years of customer feedback addressing current IT market trends for high-density

server and networking applications. The NetShelter SX provides a reliable rackmounting environment for mission-critical equipment.

SX 48ru rack

AR3107

weight (lb/kg): 304.1 / 138.23

Dimensions (in/mm):42.13 x 23.62 x 88.9 / 1070 x 600 x 2258

weight capacity - Static load (lb/kg): 3000 / 1363.6

weight capacity - Dynamic load (lb/kg): 2250 / 1022.7

SX 48ru rack

AR3157

net weight (lb/kg): 372 / 169.09

Dimensions (in/mm):42.13 x 29.53 x 88.9 / 1070 x 750 x 2258

weight capacity - Static load (lb/kg): 3000 / 1363.6

weight capacity - Dynamic load (lb/kg): 2250 / 1022.7

AR3157AR3107

Racks

90

Rac

ks

4 Post open Frame racksRack Enclosure

> Numbered RU positions

> Optimized width

> Reversible stabilization plates

> Advanced power distribution and cable management features

> For server, networking and telecom applications in secure IT environments

> Unobstructed airflow and fast, easy access to installed equipment

4 Post open Frame racks

AR3100

weight (lb/kg): 275.2 / 125.09

Dimensions (in/mm):42.13 x 23.62 x 78.4 / 1070 x 600 x 1991

weight capacity - Static load (lb/kg): 3000 / 1363.6

weight capacity - Dynamic load (lb/kg): 2250 / 1022.7

NetShelter Enclosure and Rack Accessory SKUs

Description Color

Rack Enclosures Open Frame Racks

ar3100 ar3150 ar3107 ar3157 ar2105blKar100 and ar100HD

ar200 and ar201

ar203 and ar204

ar7503: NetShelter® SX 42RU 19" Wide Recessed Rail Kit Black •

ar7504: NetShelter SX 48RU 19" Wide Recessed Rail Kit Black •

ar7505: Cable Tree for NetShelter SX Black • • • •

ar7508: NetShelter SX 42RU 23" Wide Recessed Rail Kit Black •

ar7578: NetShelter SX 48RU 23" Wide Recessed Rail Kit Black •

ar7707: NetShelter SX Wide Cable Ring Set Black • •

ar8006a: Equipment Support Rails 600mm wide White-Zinc • • •

ar8013a: NetShelter SX HP Adapter Kit – L Class/RP54xx Series Black • •

ar8113a: Cable Management Rings Black • • • • • • • •

ar8122blK: Fixed Shelf 250lb/114kg Black Black • • • • • AR203 only

ar8123blK: Sliding Shelf 100lb/45kg Black Black • • • • • •

ar8136blK: 1RU Plastic Blanking Panel Kit 19" Black (Qty – 10) Black • • • • • AR203 only

ar8136blK200: 1RU Plastic Blanking Panel Kit 19" Black (Qty – 200) Black • • • • • AR203 only

ar8425a: 1RU Horizontal Cable Organizer Black • • • • • • • •

ar8426a: 2RU Horizontal Cable Organizer Black • • • • • • • •

ar8442: Vertical Cable Organizer for NetShelter 0RU Channel Black • • • • •

Rack Cooling SKUs

Description Color

Rack Enclosures Open Frame Racks

ar3100 ar3150 ar3107 ar3157 ar2105blKar100 and ar100HD

ar200 and ar201

ar203 and ar204

acF400:Rack Air Removal Unit 100-240V 50/60Hz for NetShelter SX 19" Wide Rack

Black • •

acF402:Rack Air Removal Unit 100-240V 50/60Hz for NetShelter SX 23" Wide Rack

Black • •

acF201blK: Rack Side Air Distribution 2RU 115V 60Hz Black • • • • •

acF202blK: Rack Side Air Distribution 2RU 208/230 50/60Hz Black • • • • •

91

Rack C

oo

ling

in row rack coolingAir or Water Rack Cooling

> In row precision air conditioning for medium to large data centers

> Air or water cooling options

> Ideal for high density application

> Field replaceable components

> Rack inlet temperature controlACRP100

in row rack cooling

Specifications: ACRC100 ACRP100

cooling options: Chilled water Air

air Discharge Patterns: Horizontal Horizontal

intake air: Rear return Rear return

air Flow: 2900CFM 4800CFM

condensate Pump capacity: 1.30gal/hour 8.45gal/hour

Minimum water inlet Temperature:

7°C / 45°F -

Total System waterside Pressure Drop (psi/kpa):

6.9 / 48 -

required water Flow rate (gpm/lps):

13.2 / 0.84 -

Humidification Value: - 6.6lb/hour

compressor Type: - Reciprocating

refrigerant: - R407C

cooling capacity options: - 29kW

Input ACRC100 ACRP100

nominal input Voltage: 100V,120V 200V 3PH,208V 3PH

input Power: 1100W 13.737kW

input Frequency: 50/60Hz 50/60Hz

rack Height: 42RU 42RU

input connections:NEMA L5-20P

Hard Wire 4-wire (3PH + G)

Communications and Management

control Panel: Multi-function LCD status and control console

audible alarm:Audible and visible alarms

prioritized by severity

Dimensions (in/mm):78.4 x 11.8 x 42.1 / 1991 x 300 x 300

78.4 x 23.6 x 42.1 / 1991 x 600 x 1070

weight (lb/kg): 358 / 162.73 833 / 378.64

units per Pallet: 1

Conformance

regulatory approvals:cUL Listed,FCC Part 15 Class A,ICES-

003,Industry Canada,MEA,UL Listed,VCCI

warranty 1 year (parts only)

92

Rac

k C

oo

ling

> Air distribution for networking equipment with side-to-side airflow

> Pulls air from the front of the rack and distributes it to the side air intake

> Extends equipment life by providing proper inlet temperatures

> Performance heat removal for high density equipment in rack enclosures

> Captures exhaust heat, eliminating hot spots

> Unit-mounted LCD display to monitor alarm conditionsandadjustunitsetpoints

Conformance

regulatory approvals:cUL Listed, CE, EN 55022 Class A, EN 55024, FCC Part 15 Class A, ICES-003, IEC 61000-3-2, IEC 61000-3-3, UL Listed, VDE, VCCI

Standard warranty: 2 years repair or replace

Part Number Description

acF400:100–240V 50/60Hz for NetShelter® SX 600mm wide rack

acF402:100–240V 50/60Hz for NetShelter SX 750mm wide rack

acF126: ARU Ducting kit for 24" ceiling tiles

acF127: ARU Ducting kit for 600mm ceiling tiles

acF122: ARU Door Grille Kit

Communications & Management

control Panel: Power on/off indicator

Mechanical

Dimensions (in/mm): 3.44 x 16.98 x 26.34 / 87 x 431 x 669

weight (lb/kg): 32 / 14.55 32 / 14.55

Conformance

regulatory approvals: UL recognized CE, UL recognized

Standard warranty: 2 years repair or replace

Part Number Description

acF201blK: 115Vac, 60Hz

acF202blK: 208/230Vac, 50/60HZ

ACF400

rack air Distribution unit

rack air removal unit

Specifications ACF400 ACF402

cooling capacity options: 16.5kW 16.5kW

air Discharge Patterns: Upflow, Ducted Upflow, Ducted

air Flow: 2000CFM 2000CFM

Input

nominal input Voltage: 100V,120V, 200V, 208V, 230V

input Power: 1200W 1200W

input Frequency: 50/60Hz 50/60Hz

input connections: IEC-320 C14, NEMA 5-15P

Communications

control Panel: Multi-function LCD status and control console

Mechanical

Dimensions (in/mm):75.5 x 23.5 x 10 / 1918 x 597 x 254

75.5 x 29 x 10 / 1918 x 737 x 254

weight (lb/kg): 148 / 67.27 170 / 77.27

rack air Distribution unitSpecifications ACF201BLK ACF202BLK

air Flow: 260CFM 260CFM

amp Draw nominal: 2A 1A

Input

nominal input Voltage: 120V 200V, 208V, 230V

input Power: 150W -

input Frequency: 60Hz +/- 5Hz 50/60Hz

rack Height: 2RU 2RU

input connections: C-13, NEMA 5-15P C-13, IEC-320 C14

rack air removal unit

ACF201

93

Rack A

ccessories

rack Hardware and accessoriesCable and Mounting Accessories

> Blanking panels

> Cable management rings

> SX cable ring set and cable tree

> Vertical or horizontal cable organizer

> SX recessed rail kit and support rails

> SX HP adapter kit

> Fixed and sliding shelves

1RU Blanking Panels

AR8136BLK (Qty 10)/AR8136BLK200 (Qty 200)

Modular 1RU plastic blanking panels allow

quick and easy installation in any EIA-310-D

compliant square hole mounting rail rack or

enclosure, tool free mounting.

Cable Management

Cable Management Rings AR8113A

Facilitates side/vertical cable management.

Organizes data and power cables. Includes

mounting hardware and velcro mounting straps.

SX Cable Ring Set AR7707

Deep cable management rings to facilitate

vertical cable management in typically

networking environments.

SX Cable Tree

AR7505

Cable management accessory to facilitate

rear cable management within an enclosure

or a rack. Helps to eliminate cable stress and

maintain a neat, organized cable layout. Works

in both 42RU and 48RU racks.

Cable Organizers

Vertical Cable Organizer AR8442 Tool Free, vertical cable management accessory that allows for quick installation and takes up zero RU of space within the rack. It helps to eliminate cable stress and to organize the cable layout within the rear channels of the NetShelter® enclosure.

1RU and 2RU-U Horizontal Cable OrganizerAR8425A, AR8426A Facilitates front cable management. Integrated front cable hoops. Occupies 1RU of rack space. Includes Installation Guide, Mounting hardware.

SX Recessed Rail Kit

AR7503, AR7504, AR7508, and AR7578

Enables users to mount networking and server

equipment in the same rack or enclosure.

Includes:Installationguide,mounting

hardware, rackmounting hardware.

Support Rails for 600mm Enclosures

AR8006A

The Equipment Support Rails will support

any non-Rackmount piece of equipment that

measures 16.75" (43cm) to 17.7" (45cm) wide

and has a maximum weight of 200 lb/91kg. The

Support Rails attach to the side mounting

holes of the vertical mounting rails.

SX HP Adapter Kit

AR8013A

This adapter kit allow HP’s L Class/RP54xx Series

servers to be installed in the NetShelter® SX

enclosure. This kit is configured for the

installationofoneserver.Includes:Installation

guide, mounting hardware.

Shelves

Fixed Shelf AR8122BLK (Black) (X-CertifieD)Occupies 1RU of rack space, 4 post mounting,adjustablemountingdepth, ventilated. Includes installation guide and mounting hardware. Supports 250lb / 114kg

Sliding Shelf AR8123BLK (Black)Occupies 1RU of rack space, 4 post mounting, adjustablemountingdepth,ventilated.Includesfriction pads, installation guide, mounting hardware and user manual. Supports 100lb / 45.5kg

Sliding Shelf

94

Rack A

ccessories

95

Gen

erators

AlphaGen™ GeneratorsAdding a generator to any type of power system provides additional peace of mind. For outside plant

communication networks, a generator serves as assurance that even in severe conditions, you will be

able to keep your system up and functioning. All AlphaGen systems are engineered to have significantly

reduced noise levels, high power density, and status monitoring.

> AlphaGen 8kW-2MW SystemsCritical power applications are part of every industry; protecting them starts with reliable generators,

available in diesel, gas and LP configurations. Our EPA-compliant diesel models deliver dependable

power to a wide range of output requirements. From small-load hub and small business to large

Headend or facility backup, every generator is engineered to provide maximum power, performance,

flexibility and fuel efficiency.

> AlphaGen TelecomThe AlphaGen curbside generator system is specifically designed for outside plant communication

networks. Every AlphaGen system incorporates industry leading power technology, including natural

gas or propane powered engine generators, exclusive audible noise baffling, remote status monitoring

features and durable weather resistant enclosures.

96

Gen

erat

ors

alphagen™ 3.5kw to 2Mw SystemsGenerator Systems

> Generator solutions to most CRT and Facility Requirements

> 3.5kW to 2MW

> LP/NG/Diesel

> Single phase or Three phase

> Fixed or portable

> Communications options

> Automatic Transfer Switch

Alpha has the capability to design, install and maintain industrial generators to meet your power supply needs.

Contact an Alpha represenative for more details.

AlphaGen System

97

Gen

erators

alphagen™ TelecomGenerator Systems

alphagen Telecom

Model 3.5kW 5kW 7.5kW

Dc output Voltage:39V ±0.5V @ no load 36V configuration 39V ±0.5V @ no load 36V configuration 52V ±0.5V @ no load 48V configuration

52V ±0.5V @ no load 48V configuration 52V ±0.5V @ no load 48V configuration 104V ±0.5V @ no load 96V configuration

Dc output load regulation: 0.5V 0.5V 0.5V

output current: 39V @ 90A max / 52V @ 67A max 39V @ 128A max / 52V @ 96A max 52V @ 144A max / 104V @ 72A max

engine: 398cc, Air cooled, Single OHV 10.5hp (using natural gas fuel) 642cc, Air cooled, Twin OHV 15hp (using natural gas)

rPM: (Variable Speed): 2800 to 3600RPM 2800 to 3600RPM 2800 to 3600RPM

Acoustical Noise

dba 10' @ 100% rated load: 68.7 68.5 70.3

dba 20' @ 100% rated load: 63 62.5 64.3

dba 10' @ 70% rated load: 68.3 66.9 66.4

dba 20' @ 70% rated load: 62.6 60.9 60.4

Mechanical: CE-3x2 CE-9x2 CE-3x2 CE-9x2 PN-6x

Dimensions (in/cm):44 x 26 x 24 / 111.2 x 66 x 61

52 x 52 x 24 / 132.1 x 132.1 x 61

44 x 26 x 24 /111.2 x 66 x 61

52 x 52 x 24 / 132.1 x 132.1 x 61

39 (57 with optional pedestal) x 39.25 x 24 / 99 (144) x 100 x 61

weight (lb/kg): 383 / 174 413 / 187 383 / 174 413 / 187 338 / 174 (370/168 with optional pedestal)

APU Fuel Consumption

natural gas: 1000bTu/ft.3: 60ft3/hr 80ft3/hr 156ft3/hr

Propane gas: 2520bTu/ft.3: 0.82 gal/hr to 30ft3/hr to 3.46lb/hr 1.10gal/hr to 40ft3/hr to 4.62lb/hr 1.48gal/hr to 54ft3/hr to 6.24lb/hr

exterior Surface Temperature: Meets requirements of UL/CSA

All Models

gas inlet Pressure: 0.5 to 2 PSI Inlet Pressure (Contact Alpha Engineering for additional supply resources)

ign charger Voltage: 13.5Vdc

ign charger current: 6A max

remote interface length: 75ft max Distance depends upon installation, derating and wire gauge

Standards: UL1778, UL2200, NFPA 37/54/58 and 70, CSA C22.2 No.107.1, EMC/FCC Part 15 Class A

Features

Fuel System, controls and Monitoring:

The controls and fuel system meet applicable sections of NFPA 37, 54 and 58 for automatic unattended operation of remotely located generators. Full System Control and Status Monitoring included.

Sensors: Gas Hazard, Pad Shear, Water Intrusion and Tamper

Safety Shutdowns:Low Oil Pressure, Low Fuel Pressure Shutdown (Propane only), Over Temp, Water Intrusion,

Pad Shear, Gas Hazard (Propane or Natural Gas), Over-Speed, Over-Crank

optional Feature: ColdStartKit:Providesadditionalstartingcapabilityattemperaturesbelow-18°C/0°F

Configuration Options:

CE-3x2 3.5 or 5kW CE-9x2 3.5 or 5kWCE-3/9G Propane Storage for Generator

(For 3.5 and 5kW)

PN-6x 7.5kW

(PN-6x is not compatible with CE-3/9G)

> Cost effective extended runtime solution for outdoor powering applications

> Quiet operation, small size, and low profile allow for easier installation in populated areas

> Eliminates large quantities of batteries otherwise required for extended runtime

> Telecom grade 48Vdc outputAlphaGen Telecom

98

Gen

erators

99

Alp

ha B

uild

ing

System

s

Alpha Building SystemsBy MBSI

> Steel construction

> Reinforced concrete

> Professional workmanship

> On-site installation

> Environmentally sound

> Versatile finishing

We build the best, most diverse, line of equipment shelters, telecom equipment cabinets and

hazardous material storage buildings available. Whether you need wood, steel, fiberglass or bullet-

proofconcrete,youcancountonacost-efficientcustomsolution.Alphaprovides“turnkey”site

construction - nationwide - including tower and equipment installation.

Each concrete shelter is hand-built in a climate controlled environment, keeping materials dry and

construction on schedule. Your shelter will move down an assembly line where skilled workers

meticulously complete tasks they have perfected through ongoing training, repetition and strict

quality control. In addition, periodic inspections are performed by State or third-party building

inspectors. The result brings you an equipment shelter well capable of protecting your valuable

contents for many decades.

100

No

tes

notes

notes

102

No

tes

alpha Technologies Due to continuing product development, Alpha reserves the right to change specifications without notice. Copyright © 2008 Alpha Technologies Inc. All Rights Reserved. Alpha is a registered trademark of Alpha Technologies. (2/2008)

www.alpha.com

Alpha Technologies Ltd.4084 McConnell CourtBurnaby BC V5A 3N7CanadaTel: +1 604 430 1476Fax: +1 604 430 8908

Alpha Technologies Europe Ltd.Twyford House Thorley Bishop’s Stortford, HertfordshireCM22 7PAUnited KingdomTel: +44 1279 501110Fax: +44 1279 659870

Alpha Technologies GmbHHansastrasse 8D 91126 SchwabachGermanyTel: +49 9122 79889 0Fax: + 49 9122 79889 21

AlphaTec Ltd.339 Saint Andrews StreetSuite 101 Andrea Chambers3307 Limassol CyprusTel: +357 25 375675Fax: +357 25 359595

AlphaTEK oooKhokhlovskiy Pereulok 16Stroenie 1 Office 403 109028 MoscowRussiaTel: +7 495 916 1854Fax: +7 495 916 1349

Alpha TechnologiesUnit 504, 5/F, Fourseas Bldg.No. 208-212 Nathan RoadKowloon, Hong KongChinaTel: +852 2736 8663Fax: +852 2199 7988

Alpha Technologies Inc.3767 Alpha WayBellingham WA 98226USATel: +1 360 647 2360Fax: +1 360 671 4936

Visit www.alpha.com for additional headend power information.