HARTING D-Sub Selection Guidebackend.harting.com/.../I_O/HARTING_D-Sub_Selection_Guide_-_EN.… ·...

10
HARTING D-Sub Selection Guide

Transcript of HARTING D-Sub Selection Guidebackend.harting.com/.../I_O/HARTING_D-Sub_Selection_Guide_-_EN.… ·...

Page 1: HARTING D-Sub Selection Guidebackend.harting.com/.../I_O/HARTING_D-Sub_Selection_Guide_-_EN.… · HARTING D-Sub Device Connectivity HARTING D-Sub Selection Guide Harting Connectivity

HARTINGD-Sub Selection Guide

Page 2: HARTING D-Sub Selection Guidebackend.harting.com/.../I_O/HARTING_D-Sub_Selection_Guide_-_EN.… · HARTING D-Sub Device Connectivity HARTING D-Sub Selection Guide Harting Connectivity

HARTING D-Sub Device Connectivity

HARTING D-Sub Selection Guide

Harting Connectivity & Networks generates solutions throughout the triad of Installation Technology, Device Connectivity, and Smart Network Infrastructure for all automation lifelines – namely data, signals and power. In line with this strategic course, the Harting D-Sub connectors provide universal solutions for specific user

applications. A consistent, ongoing innovation process ensures that users of Harting’s continuously expanding D-Sub product range always benefit from the latest interface technology.

The Harting D-Sub range consists of:

Accessories like hoods and tools

HARTING has added an entire series of rectangular D-Sub SMT connectors to its product range. This new series allows customers to use both the reflow process and the standard vacuum pick-and-place systems.The design has been optimized with a view to a reliable processing and a long service life.

HARTING’s D-Sub IP 67 connector series is fully dedicated to water resistant applications and fulfils the rigorous requirements of IP 67.This product family is aimed at equipment placed in harsh environments, indoors and outdoors, where connectors are exposed to moisture, dust and dirt.

HARTING’s range of D-Sub Filter connectors offers complete flexibility in filtering capability through the use of a unique technology. The filter elements are mounted on a PCB integrated into the connector allowing the combination of different filters in one connector.The complete D-Sub Filter connector range can be used with reflow soldering processes (Surface Mount Compatible / SMC).

HARTING’s D-Sub Mixed connector range combines the advantages of an industry standard I/O interconnect product with the customisation flexibility for any application.

The main benefit of HARTING’s D-Sub High Density connectors is to provide a higher density within the standard D-Sub shell pattern. It allows design engineers to enhance their equipment by including more data paths with the same panel cut out.15, 26, 44, 62 and 78 pins are respectively designed in a 9, 15, 25, 37 and 50 pin standard D-Sub size shell.

HARTING’s D-Sub Standard connectors‘ range includes connectors with 9 to 50 straight, right-angled, right-angled low profile or US foot print style contacts. Most connectors are offered alternatively with turned or stamped contacts.

All part numbers listed in the selection guide refer to connectors in performance level 2 (performance level 3 for High Density connectors) and are only a small extract of our huge D-Sub range. You can find more detailed information at www.HARTING.com.

D-Sub accessories

D-Sub SMT connectors

D-Sub Waterproof IP 67 connectors

D-Sub Filter connectors

D-Sub Mixed connectors

D-Sub High Density connectors

D-Sub Standard connectors

Page 3: HARTING D-Sub Selection Guidebackend.harting.com/.../I_O/HARTING_D-Sub_Selection_Guide_-_EN.… · HARTING D-Sub Device Connectivity HARTING D-Sub Selection Guide Harting Connectivity

915253750

9152537

9152537

9152537

9152537

915253750

9152537

9152537

9152537

9152537

9152537

915253750

09 67 009 475509 67 015 475509 67 025 475509 67 037 475509 67 050 4755

09 66 111 650x09 66 211 650x09 66 311 650x09 66 411 650x

09 67 118 650x09 67 218 650x09 67 318 650x09 67 418 650x

09 66 112 660x09 66 212 660x09 66 312 660x09 66 412 660x

09 66 112 660x09 66 212 660x09 66 312 660x09 66 412 660x

09 66 114 650x09 66 214 650x09 66 314 650x09 66 414 650x09 66 514 650x

09 68 153 561x09 68 253 561x09 68 353 561x09 68 453 561x

09 66 151 651x09 66 251 651x09 66 351 651x09 66 451 651x

09 66 108 000109 66 208 000109 66 308 000109 66 408 0001

09 66 152 661x09 66 252 661x09 66 352 661x09 66 452 661x

09 66 152 661x09 66 252 661x09 66 352 661x09 66 452 661x

09 66 154 651x09 66 254 651x09 66 354 651x09 66 454 651x09 66 554 651x

09 67 009 565509 67 015 565509 67 025 565509 67 037 565509 67 050 5655

09 65 121 670x09 65 221 670x09 65 321 670x09 65 421 670x

09 66 128 670x09 66 228 670x09 66 328 670x09 66 428 670x

09 65 122 680x09 65 222 680x09 65 322 680x09 65 422 680x

09 65 122 680x09 65 222 680x09 65 322 680x09 65 422 680x

09 66 124 670x09 66 224 670x09 66 324 670x

09 68 163 581x09 68 263 581x09 68 363 581x09 68 463 581x

09 65 161 671x09 65 261 671x09 65 361 671x09 65 461 671x

09 66 108 000109 66 208 000109 66 308 000109 66 408 0001

09 65 162 681x09 65 262 681x09 65 362 681x09 65 462 681x

09 65 162 681x09 65 262 681x09 65 362 681x09 65 462 681x

09 66 164 671x09 66 264 671x09 66 364 671x

D-Su

b ST

ANDA

RD

Turned solder pins, straight

Stamped solder pins, straight without grounding board locks

IDC termination

Stamped solder pins, angled without grounding board locks

Low profile stamped solder pins, angled without grounding board locks

Press-fit stamped, straight without board locks, flange height 5.7 mm

US footprint stamped solder pins with board locks

Stamped solder pins, straight with grounding board locks

Cable clamp

Stamped solder pins, angled with grounding board locks

Low profile stamped solder pins, angled with grounding board locks

Press-fit stamped, straight with board locks, flange height 5.7 mm

Please insert digit x for flange thread or fitted female screw locks for M3 x = 1 for 4-40 UNC x = 2 for fitted screw locks 4-40 UNC x = 3

Please insert digit x for flange thread or fitted female screw locks for through holes x = 0 for M3 x = 1 for 4-40 UNC x = 2

Please insert digit x for flange thread or fitted female screw locks for M3 x = 1 for 4-40 UNC x = 2 for fitted screw locks 4-40 UNC x = 3

Please insert digit x for flange thread or fitted female screw locks for M3 x = 5 for 4-40 UNC x = 6 for fitted screw locks 4-40 UNC x = 7

Please insert digit x for flange thread or fitted female screw locks for M3 x = 5 for 4-40 UNC x = 6 for fitted screw locks 4-40 UNC x = 7

Please insert digit x for flange thread or fitted female screw locks for M3 x = 1 for 4-40 UNC x = 2 for fitted screw locks 4-40 UNC x = 3

Pictures Characteristics No. of contacts male female

Page 4: HARTING D-Sub Selection Guidebackend.harting.com/.../I_O/HARTING_D-Sub_Selection_Guide_-_EN.… · HARTING D-Sub Device Connectivity HARTING D-Sub Selection Guide Harting Connectivity

915253750

1526446278

1526446278

1526446278

915253750

1526446278

 5W1 7W2 9W411W113W313W617W221W121WA424W725W327W236W443W2

1526446278

09 67 009 471509 67 015 471509 67 025 471509 67 037 471509 67 050 4715

09 56 100 470409 56 200 470409 56 300 470409 56 400 470409 56 500 4704

09 56 151 750009 56 251 750009 56 351 750009 56 451 750009 56 551 7500

09 56 152 761x09 56 252 761x09 56 352 761x09 56 452 761x09 56 552 761x

09 67 009 470109 67 015 470109 67 025 470109 67 037 470109 67 050 4701

09 67 000 347609 67 000 847609 67 000 547609 67 000 7476

09 56 100 470109 56 200 470109 56 300 470109 56 400 470109 56 500 4701

09 69 101 505109 69 201 507209 69 301 509409 69 201 511109 69 301 513309 69 401 513609 69 301 517209 69 301 521109 69 401 521409 69 501 524709 69 401 525309 69 401 527209 69 501 536409 69 501 5432

09 56 151 751x09 56 251 751x09 56 351 751x09 56 451 751x09 56 551 751x

09 67 000 82x809 67 000 72x8

09 67 000 82x7

09 67 009 561509 67 015 561509 67 025 561509 67 037 561509 67 050 5615

09 56 100 560409 56 200 560409 56 300 560409 56 400 560409 56 500 5604

09 56 161 770009 56 261 770009 56 361 770009 56 461 770009 56 561 7700

09 56 162 781x09 56 262 781x09 56 362 781x09 56 462 781x

09 67 009 560109 67 015 560109 67 025 560109 67 037 560109 67 050 5601

09 67 000 357609 67 000 857609 67 000 557609 67 000 7576

09 56 100 560109 56 200 560109 56 300 560109 56 400 560109 56 500 5601

09 69 111 505109 69 211 507209 69 311 509409 69 211 511109 69 311 513309 69 411 513609 69 311 517209 69 311 521109 69 411 521409 69 511 524709 69 411 525309 69 411 527209 69 511 536409 69 511 5432

09 56 161 771x09 56 261 771x09 56 361 771x09 56 461 771x09 56 561 771x

09 67 000 81x809 67 000 71x8

09 56 000 81x7

D-S

ub

STAN

DARD

D-S

ub

HIG

H D

eNSI

TyD-

Sub

MIx

eD

Turned solder cups

High Density, solder cups

High Density, solder pins, straight

High Density, solder pins, angled with board locks

Crimp terminal

Turned crimp contacts, performance level 1AWG 22-18AWG 24-20AWG 26-22AWG 28-24

High Density, crimp terminal

Mixed shells with signal solder cup contacts

High Density, solder pins, straightwith spacer and board locks

Stamped crimp contactsAWG 24-20AWG 28-24

High Density, stamped crimp contactsAWG 26-24

Please insert digit x for flange thread or fitted female screw locks for 4-40 UNC x = 2 for fitted screw locks 4-40 UNC x = 3

Please insert digit x for flange thread or fitted female screw locks for 4-40 UNC x = 2 for fitted screw locks 4-40 UNC x = 3

Please insert digit x for 500 pieces bulk x = 7 for 500 pieces / reel x = 6 for 10,000 pieces / reel x = 5

Please insert digit x for 500 pieces bulk x = 7 for 500 pieces / reel x = 6 for 10,000 pieces / reel x = 5

Pictures Characteristics No. of contacts male female

Page 5: HARTING D-Sub Selection Guidebackend.harting.com/.../I_O/HARTING_D-Sub_Selection_Guide_-_EN.… · HARTING D-Sub Device Connectivity HARTING D-Sub Selection Guide Harting Connectivity

 5W1 7W211W113W317W221W121WA436W4

10 A20 A30 A40 A

RG 174RG 178RG  58

10 A20 A30 A40 A

RG 179RG  59RGD 179

2W22W2C3W33W3C5W57W78W8

09 69 102 005109 69 202 007209 69 202 011109 69 302 013309 69 302 017209 69 302 021109 69 402 021409 69 502 0364

09 69 181 542009 69 181 542109 69 181 542209 69 181 5423

09 69 181 514009 69 181 514109 69 181 5143

09 69 187 006009 69 187 006109 69 187 006209 69 187 0063

09 69 182 542009 69 182 542109 69 182 542209 69 182 5423

09 69 182 523009 69 182 523209 69 182 5233

09 69 181 2550

09 69 182 2550

09 69 100 052209 69 100 002209 69 200 003309 69 200 063309 69 300 005509 69 400 007709 69 400 0088

09 69 112 005109 69 212 007209 69 212 011109 69 312 013309 69 312 017209 69 312 021109 69 412 021409 69 512 0364

09 69 281 542009 69 281 542109 69 281 542209 69 281 5423

09 69 281 514009 69 281 514109 69 281 5143

09 69 287 006009 69 287 006109 69 287 006209 69 287 0063

09 69 282 542009 69 282 542109 69 282 542209 69 282 5423

09 69 282 523009 69 282 523209 69 282 5233

09 69 281 2550

09 69 282 2550

09 69 110 052209 69 110 002209 69 210 003309 69 210 063309 69 310 005509 69 410 007709 69 410 0088

HARTING D-Sub Selection Guide

D-Su

b M

IxeD

SPeC

IAl

CoN

TACT

S

Mixed shells for signal crimp contactsand special contacts

Signal crimp contacts see page 3

Power contacts, solder cup

Coaxial contacts for 50 Ω

Many other coaxial contacts are available on request

Pneumatic contacts

Power contacts, crimp

Coaxial contacts for 75 Ω

Many other coaxial contacts are available on request

High voltage contacts, solder version

High voltage contacts, crimp

Mixed shells for special contacts

2 mm2.6 mm3 mm4 mm

Pictures

Pictures

Pictures

Pictures

Characteristics

Characteristics

Characteristics

Characteristics

No. of contacts

Rating

for cables

inner Ø air tube

male

male

male

male

female

female

female

female

Page 6: HARTING D-Sub Selection Guidebackend.harting.com/.../I_O/HARTING_D-Sub_Selection_Guide_-_EN.… · HARTING D-Sub Device Connectivity HARTING D-Sub Selection Guide Harting Connectivity

HARTING D-Sub Selection Guide

91525

9152537

9152537

9152537

9152537

09 64 112 780009 64 212 780009 64 312 7800

09 64 111 780009 64 211 780009 64 311 780009 64 411 7800

09 64 113 780209 64 213 780209 64 313 780209 64 413 7802

09 64 112 72xy09 64 212 72xy09 64 312 72xy09 64 412 72xy

09 64 111 72xy09 64 211 72xy09 64 311 72xy09 64 411 72xy

09 64 122 780009 64 222 780009 64 322 7800

09 64 121 780009 64 221 780009 64 321 780009 64 421 7800

09 64 123 780209 64 223 780209 64 323 780209 64 423 7802

09 64 122 72xy09 64 222 72xy09 64 322 72xy09 64 422 72xy

09 64 121 72xy09 64 221 72xy09 64 321 72xy09 64 421 72xy

9152537

09 64 100 72xx09 64 200 72xx09 64 300 72xx09 64 400 72xx

9152537

09 64 114 72xy09 64 214 72xy09 64 314 72xy09 64 414 72xy

09 64 124 72xy09 64 224 72xy09 64 324 72xy09 64 424 72xy

D-Su

b FI

lTeR

Filter, turned solder pins, straight with through holes

Filter, turned solder buckets with through holes

Filter, turned solder pins, right angled, with 4-40 UNC flange thread

Filter, turned solder pins, straight, with grounding board locks

Filter, turned solder buckets with through holes / clinch nut

Please insert digits x and y for   47 pF x = 1 for 4-40 UNC y = 5 for  470 pF x = 2 for M3 y = 6 for 1000 pF x = 3 for 3900 pF x = 4

Please insert digits x and y for   47 pF x = 1 for through holes y = 0 for  470 pF x = 2 for 4-40 UNC y = 7 for 1000 pF x = 3 for M3 y = 8 for 3900 pF x = 4

Pictures Characteristics No. of contacts male female

C-FI

lTeR

FeRR

ITe-

FIlT

eR

Please insert digits xx for   47 pF xx = 10 for  470 pF xx = 20 for 1000 pF xx = 30 for 3900 pF xx = 40

Male / female filter adapters

Please insert digits x and y for   47 pF x = 1 for through holes y = 1 for  470 pF x = 2 for 4-40 UNC y = 2 for 1000 pF x = 3 for M3 y = 3 for 3900 pF x = 4 for 4-40 UNC female screw locks y = 4 for M3 female screw locks y = 5

Filter, turned solder pins, right angled, with brackets and board locks

Page 7: HARTING D-Sub Selection Guidebackend.harting.com/.../I_O/HARTING_D-Sub_Selection_Guide_-_EN.… · HARTING D-Sub Device Connectivity HARTING D-Sub Selection Guide Harting Connectivity

91525

91525

91525

91525

915253750

915253750

915253750

915253750

915253750

915253750

09 67 509 y71509 67 515 y71509 67 525 y715

09 67 709 y71509 67 715 y71509 67 725 y715

09 67 509 y77509 67 515 y77509 67 525 y775

09 67 509 y75809 67 515 y75809 67 525 y758

09 67 609 y71509 67 615 y71509 67 625 y71509 67 637 y71509 67 650 y715

09 67 809 y71509 67 815 y71509 67 825 y71509 67 837 y71509 67 850 y715

09 67 609 y77509 67 615 y77509 67 625 y77509 67 637 y77509 67 650 y775

09 67 609 y75809 67 615 y75809 67 625 y75809 67 637 y75809 67 650 y758

09 67 509 x61509 67 515 x61509 67 525 x615

09 67 709 x61509 67 715 x61509 67 725 x615

09 67 509 x67509 67 515 x67509 67 525 x675

09 67 509 x65809 67 515 x65809 67 525 x658

09 67 009 043x09 67 015 043x09 67 025 043x09 67 037 043x09 67 050 043x

09 67 609 x61509 67 615 x61509 67 625 x61509 67 637 x61509 67 650 x615

09 67 809 x61509 67 815 x61509 67 825 x61509 67 837 x61509 67 850 x615

09 67 609 x67509 67 615 x67509 67 625 x67509 67 637 x67509 67 650 x675

09 67 609 x65809 67 615 x65809 67 625 x65809 67 637 x65809 67 650 x658

09 67 009 053x09 67 015 053x09 67 025 053x09 67 037 053x09 67 050 053x

915253750

09 67 409 471509 67 415 471509 67 425 471509 67 437 471509 67 450 4715

09 67 409 561509 67 415 561509 67 425 561509 67 437 561509 67 450 5615

D-Su

b W

ATeR

PRo

oF

IP 6

7

IP 67, turned solder cups with rear plastic mounting frame

IP 67, turned solder cups with front plastic mounting frame

IP 67, turned straight to PCB, spacer and board lock rear plastic mounting frame

IP 67, turned angled to PCB, spacer and board lock rear plastic mounting frame

IP 67, black plastic hood

IP 67, turned solder cups with rear metal mounting frame

IP 67, turned solder cups with front metal mounting frame

IP 67, turned straight to PCB, spacer and board lock rear metal mounting frame

IP 67, turned angled to PCB, spacer and board lock rear metal mounting frame

IP 67, metallized plastic hood

Please insert digits x and y for 4-40 UNC x = 7; y = 6 for M3 x = 9; y = 8

Please insert digits x and y for 4-40 UNC x = 7; y = 6 for M3 x = 9; y = 8

Please insert digits x and y for 4-40 UNC x = 7; y = 6 for M3 x = 9; y = 8

Please insert digits x and y for 4-40 UNC x = 7; y = 6 for M3 x = 9; y = 8

Please insert digit x for locking screws 4-40 UNC x = 8 for locking screws M3 x = 9

Pictures Characteristics No. of contacts male female

IP 67, turned solder cups

Page 8: HARTING D-Sub Selection Guidebackend.harting.com/.../I_O/HARTING_D-Sub_Selection_Guide_-_EN.… · HARTING D-Sub Device Connectivity HARTING D-Sub Selection Guide Harting Connectivity

9152537

9152537

9152537

915253750

915253750

9152537

9152537

09 67 009 043009 67 015 043009 67 025 043009 67 037 0430

09 67 009 043109 67 015 043109 67 025 043109 67 037 0431

09 55 156 66xx 74109 55 256 66xx 74109 55 356 66xx 74109 55 456 66xx 741

09 55 156 66xx 74109 55 256 66xx 74109 55 356 66xx 74109 55 456 66xx 741

09 55 115 66xx 74109 55 215 66xx 74109 55 315 66xx 74109 55 415 66xx 741

09 67 009 043409 67 015 043409 67 025 043409 67 037 0434

09 67 009 043509 67 015 043509 67 025 043509 67 037 0435

09 55 166 68xx 74109 55 266 68xx 74109 55 366 68xx 74109 55 466 68xx 741

09 67 009 044209 67 015 044209 67 025 044209 67 037 044209 67 050 0442

09 67 009 044309 67 015 044309 67 025 044309 67 037 044309 67 050 0443

09 55 166 68xx 74109 55 266 68xx 74109 55 366 68xx 74109 55 466 68xx 741

09 55 129 68xx 74109 55 229 68xx 74109 55 329 68xx 74109 55 429 68xx 741

09 67 001 996509 67 000 9971

915253750

09 67 009 057309 67 015 057309 67 025 057309 67 037 057309 67 050 0573

09 67 001 996509 67 000 9971

D-Su

b SM

TD-

Sub

ACCe

SSo

RIeS

Plastic hood top and side entry metallized

Plastic hood top and side entry black

SMT standard, stamped solder pins, angledwith grounding board locks

Plastic hood top entryblack

Plastic hood top entrymetallized

SMT low profile, stamped solder pins, angledwith grounding board locks

SMT standard, stamped solder pins, straightwithout grounding board locks

Please insert digits xx for M3 nut xx = 11 for 4-40 UNC nut xx = 12 for fitted M3 female screw locks xx = 21 for fitted 4-40 UNC female screw locks xx = 22

Please insert digits xx for M3 nut xx = 15 for 4-40 UNC nut xx = 16 for fitted M3 female screw locks xx = 19 for fitted 4-40 UNC female screw locks xx = 20

Please insert digits xx for M3 nut xx = 11 for 4-40 UNC nut xx = 12 for fitted M3 female screw locks xx = 21 for fitted 4-40 UNC female screw locks xx = 22

Pictures

Pictures

Characteristics

Characteristics

No. of contacts

No. of contacts

male

Screws 4-40 uNC

female

Screws M3

Plastic hood side entrygrey, with internal metal screening

Knurled screw with grey head

thread M3 thread 4-40 UNC

Page 9: HARTING D-Sub Selection Guidebackend.harting.com/.../I_O/HARTING_D-Sub_Selection_Guide_-_EN.… · HARTING D-Sub Device Connectivity HARTING D-Sub Selection Guide Harting Connectivity

HARTING D-Sub Selection Guide

915253750

91525

9 - 379 - 379 - 37

50

915253750

915253750

61 03 001 y01061 03 001 y01661 03 001 y01761 03 001 y01861 03 001 y019

61 03 001 y01361 03 001 y01461 03 001 y015

09 67 009 033509 67 015 033509 67 025 033509 67 037 033509 67 050 0335

09 67 009 034909 67 015 034909 67 025 034909 67 037 034909 67 050 0349

61 03 001 x01061 03 001 x01661 03 001 x01761 03 001 x01861 03 001 x019

61 03 001 x01361 03 001 x01461 03 001 x015

61 03 000 014161 03 000 014461 03 000 014361 03 000 0145

09 99 000 050909 99 000 050409 99 000 0512

09 99 000 050109 99 000 050709 99 000 050309 99 000 050809 99 000 051509 99 000 051809 99 000 0519

09 99 000 017509 99 000 053509 99 000 050109 99 000 053109 99 000 017109 99 000 0513

09 67 009 033409 67 015 033409 67 025 033409 67 037 033409 67 050 0334

09 67 009 034409 67 015 034409 67 025 034409 67 037 034409 67 050 0344

915253750

09 67 009 034809 67 015 034809 67 025 034809 67 037 034809 67 050 0348

09 67 009 034309 67 015 034309 67 025 034309 67 037 034309 67 050 0343

915253750

09 67 009 033609 67 015 033609 67 025 033609 67 037 033609 67 050 0336

09 67 009 033309 67 015 033309 67 025 033309 67 037 033309 67 050 0333

D-Su

b AC

CeSS

oRI

eS

PoW

eRCo

AxIA

lSI

GNAl

Metal hood top and side entrywith different screw options

Metal hood side entrywith different screw options

Cable clamp

Hand crimp tool for the power contactsLocator for the power contacts 10 A to 40 AInsertion / Removal tool

Hand crimp tool for the inner contactLocator for the inner coaxial contactHand crimp tool for the outer ferruleDie for the outer ferruleDie for the outer ferruleDie for the outer ferruleDie for the outer ferrule

Hand crimp tool for the standard contactsHand crimp tool for the high density contactsHand crimp tool for turned signal contactsLocator for turned signal contactsInsertion / Removal tool for the standard contactsInsertion / Removal tool for the high density contacts

Metal hood side entry with cable clamp

Metal hood top entry with cable clamp

Please insert digits x and y for knurled screw x = 0; y = 3 for hexagonal screw with

captive washer x = 2; y = 1

Pictures Characteristics No. of contacts Screws 4-40 uNC Screws M3

Metal hood top entrywith grommet

Metal hood side entrywith grommet

Cable diameter  5 -  7 mmCable diameter  7 - 10 mmCable diameter 10 - 12 mmCable diameter 11 - 14 mm

Page 10: HARTING D-Sub Selection Guidebackend.harting.com/.../I_O/HARTING_D-Sub_Selection_Guide_-_EN.… · HARTING D-Sub Device Connectivity HARTING D-Sub Selection Guide Harting Connectivity

HARTING Technology GroupMarienwerderstr. 3, 32339 Espelkamp – GermanyP.O. Box 11 33, 32325 Espelkamp – GermanyPhone +49 5772 47-0, Fax +49 5772 [email protected]

MO/

2013

-05-

31/1

.0

98

32 0

12 0

201

vers

ion

2