Critical Facility Grounding - John Howard - Lyncole XIT Grounding
HARSH & HAZARDOUS RECEPTACLE SOLUTIONS€¦ · KILLARK VERSAMATE® RECEPTACLES R6 EXCLUSIVE...
Transcript of HARSH & HAZARDOUS RECEPTACLE SOLUTIONS€¦ · KILLARK VERSAMATE® RECEPTACLES R6 EXCLUSIVE...
HARSH & HAZARDOUS RECEPTACLE SOLUTIONS
Class I, Div. 1 & 2Class I, Div. 2; Type 4XZones 1 & 2
RECEPTACLES MINI-CATALOGScan QR Code withyour mobile device
EXPANDING RANGE OF HARSH & HAZARDOUS RECEPTACLE DEVICES
Ranging from 20A blade style to 200AMP pin & sleeve devices, Killark provides numerous and field proven solutions for safely supplying power to fixed and portable equipment in hostile environments.
Interchangeability with other manufacturers configurations provides user flexibility for real world applications. The range also has exclusive convenience features like breech-lock caps with "3rd Hand" notch.
Devices include plugs, receptacles, panel receptacles, and connectors to extend the reach of portable equipment. For personnel safety, ground fault protected receptacles, both portable and fixed, are available.
QUICK LOCATOR TO PRODUCTS IN THIS MINI-CATALOG
VersaMate®
Series VSQ-FSSwitched ReceptaclePage R13
VersaMate®
Series N4X30A Plug & ReceptaclePage R7
ACCEPTOR® Series UGRCConnectorsPage R19
VersaMate®
Series N4X150A Plug & ReceptaclePage R10
ACCEPTOR® Series UGRFGFI ProtectedPage R21
ACCEPTOR® Series UGRPPanel Mount ReceptaclesPage R20
VersaMate®
Series N4X200A Plug & ReceptaclePage R11
ACCEPTOR® Series UGFIGFCI ProtectedPage R22
ACCEPTOR® Series UGRBladed Type Plug & ReceptaclePage R17
VersaMate®
Series N4X100A Plug & ReceptaclePage R9
ACCEPTOR® Series UGRSSquare ReceptaclesPage R21
VersaMate®
Series VSQSwitched ReceptaclePage R12
Installation AccessoriesPage R23
Receptacle Product Range From Killark - Back Cover
VersaMate®
Series VBQBreaker ProtectedPage R14
VersaMate®
Series N4X60A Plug & ReceptaclePage R8
NEW!
NEW!
Quick Wiring Plug
NEW VERSAMATE ® RECEPTACLES
KILLARK VERSAMATE® RECEPTACLES
R4
INTRODUCTION
Plugs:Octagonal style (Patented) for a firm and sure grip when connecting or disconnecting is fea-tured on both plug and cable connector bodies. Insulators have high mechanical and dielectric strength and “Low Arc Tracking.” “Increased Safety” type box terminals with gripper ribs securely clamp around conductors. Funneled conductor entry chambers lead all properly stripped conductors into terminals simultaneously. NEMA 4X rating when inserted into VersaMate receptacle and locking ring is tightened. Includes suitability for Type P marine cable.
Receptacles:Exclusive Patented “Breech-Lock” cap serves as either flip lid or screw cover. Receptacle is NEMA 3R with lid snapped shut or NEMA 4X with lid turned shut or when VersaMate plug is inserted and locking ring tightened. Patented notch in cap arm holds cap open for easy plug insertion or maintenance. Patented pin design uses slot-ted spring clip which avoids excessive wear while providing con-tinuous electrical pin to sleeve contact. VersaMate® receptacles use the same “Increased Safety” terminals and funnel design as VersaMate® plugs.
Cable Clamping Assembly:Plugs and cable connectors are supplied with an exclusive neo-prene “Onion Skin” peel-away type grommet. The VersaMate® cable clamp system captures cable with four grip points using only two tightening screws. Clamp guide assembly provides a firm fit over a wide range of cable diameters. Non-removable set screws prevent clamp guide assembly from backing out. Clamps have smooth contoured shoulder design to prevent snags or damage when moving equipment.
Back Boxes:VersaMate back boxes come in a variety of mounting styles. Exclusive “blind” recep-tacle mounting holes prevent moisture from entering box via thread cavities. Boxes come with a green grounding screw.
THE FIRST NEMA 4X RATED LINE OF METALLIC PLUGS & RECEPTACLES.
VersaMate® metallic pin & sleeve plugs & receptacles are designed for heavy duty industrial use. These devices sup-ply power to both fixed and portable electrical equipment including pumps, generators, welders, vacuums, blowers and similar apparatus. Suitable for indoor or outdoor use. Applications include the wet, cold, hosedown, hazardous or corrosive areas in such industrial applications as: • Pulp & Paper Mills • Breweries• Electrical Power Plants • Refineries• Petrochemical Plants • Chemical Plants• Wastewater Treatment • Grain Facilities • Marine, Docks, Ports • Textile Manufacturing• Construction Sites • Food Processing Facilities
Standard Materials:Copper-free aluminum construction with electrostatically applied epoxy/polyester finish. Contacts are brass with a patented beryllium copper spring tensioner. External screws are 316 stainless steel.
Features:The VersaMate product line includes 30, 60, 150j, 100 and 200 Amp plugs, receptacles and connectors with a full range of back boxes. Popular options include reverse service and polarization. The VersaMate line is FULLY INTERCHANGEABLEj with UL1686 configured and listed devices such as Crouse-Hinds® Arktite® or Appleton® Powertite®. Standard location receptacle bolt hole patterns match competitive back boxes so users can upgrade to VersaMate without changing back boxes in instances where changing the conduit system is difficult.
600 VAC/250VDC; 50-400 HertzNEMA 3, 4, 4XClass I, Div. 1 & 2, Groups B,C,D; NEMA 7 B,C,DkClass l, Zones 1 & 2, llB+H2, llAkClass ll, Div. 1 & 2, Groups F & G;NEMA 9 F,GkClass lllk
jVersaMate® components are UL classified and intermateable with other UL 1686-C1 configured devices (when installed in accordance with instructions furnished with device). Assemblies containing components from other manu-facturers would have the NEMA type rating of the lowest rated device. 150A models UL intermateable w/Appleton® Powertite® only.
kSee product pages for specific ratings.Arktite® is a registered trademark of Crouse-Hinds®.
Powertite® is a registered trademark of Appleton®.
VSQ VBQVR/VP
NEWALLEN/SLOTTERMINALS
FEATURES-SPECIFICATIONS
KILLARK RECEPTACLES
KILLARK VERSAMATE® RECEPTACLES
WWW.HUBBELL-KILLARK.COM R5
FEATURES/COMPARISONS
New Allen/slot terminal screws do not contact or machine conductor. Allows higher torque values typical in the oil industry.
VersaMate original Phillips/slot “Increased Safety” type terminals reduce connection fatigue. Screws do not contact or machine conduc-tor and are under spring tension to reduce loosening and pullout due to vibration.
Conventional screw type terminals. Screws“machine” (grind or fray) conductor. Screws are not under tension and more easily loos-en from heating and cooling cycles or from vibration. Screws can fall out (and be lost) during initial ship-ment - requires reassembly.
“Breech-Lock” design serves as both flip lid or screw cover style. Special notch in lid arm holds cover open to ease plug insertion or maintenance.
Conventional caps: user must choose between flip lid’s convenience or screw cover’s better sealing capa-bilities. Broken chains can mean lost covers.
Multiple gaskets require trial & error sizing to be sure of best fit and seal.
*Slip pencil or screwdriver into notch.
TERMINALS
GASKET
ALLEN/SLOTTERMINALS
• Exclusive Onion-Skin Gasket - Perfect Cable Fit• Exclusive 4-Point Cable Grip - Uses only 2 Recessed Screws• Exclusive Breech-Lock Cap - Flip or Screw-On - Notch to hold open
NEW!KILLARK BRAND
• First NEMA 4X - Still the BEST!
• Exclusive interior gasketing
• Exclusive Terminal Designs - No conductor machining - Allen or Phillips types
OTHER BRANDS
CAP
REVERSE SERVICE: S39Add suffix S39 for factory Reverse Service of recep-tacles, plugs or connectors. Receptacles or connectors are assembled with plug interiors while plugs are assembled with receptacle interiors. For applications where the plug is energized (i.e. from a genera-tor) to feed a non-energized receptacle. Prevents easy contact with energized ex-posed pins. This conversion can be performed in the field with a complementary plug and receptacle (30A to 150A devices shown on pages R7-R10). 200A Amp devices shown on page PR7 are a factory-only option. Reverse Service is not for hazardous locations.
POLARIZED OPTION: S37Add suffix S37 for special polarity.Can prevent connection between mismatched voltages or frequencies in areas where devices of the same amperage, poles and grounding style are used. Receptacle or connector interiors are rotated 22-1/2° to the right; plug is rotated oppo-site to match. This is a factory only option.
Standard S37 Option
Exclusive “Onion Skin” style gasket assures a tight seal around cable. Skin layers are removed from a single gasket to adjust for various cable diam-eters.
KILLARK VERSAMATE® RECEPTACLES
R6
EXCLUSIVE FEATURES/GROUNDING
EXCLUSIVE FEATURES & GROUNDING METHODSPatented Exclusive “Breech-Lock” cap serves as either flip lid or screw cover
PatentedSpecial notch is designed to hold cap open for easy field service or plug insertion with two free hands
Custom pin design using slotted spring clip to provide superior contact and reliability
Exclusive neoprene “Onion Skin” peel-away type gasket for the ultimate in sealing a variety of cable sizes
The VersaMate® Cable clamp system captures cable with four grip points using only two tightening screws. Provides secure grip without damaging the cable insulation
Smooth shoulder contour prevents snags & hang ups
Funneled wiring chamber design for fast and accurate conductor insertion to speed assembly. All wires can be inserted at one time
Patented Body style with octagonal shape for easy grip
P
P
Style I
In a Style I plug, the cable’s ground conductor is bonded to the plug housing by means of solderless connector. The receptacle is grounded by being part of a grounded conduit system. Upon insertion, detent springs in the receptacle housing contact and ground the plug housing before current carrying poles. All poles are current carrying.
GROUNDING: To minimize the danger of electrical shock when utiliz-ing portable equipment, the National Electrical Code requires exposed metal parts be grounded if operated at more than 150 volts to ground. The VersaMate® plug & receptacle system is available in two ground-ing styles. Please note Style I and II devices cannot be intermated.
Style II
In a Style II plug, the cable’s ground conductor is bonded to the extra grounding pole and to the plug housing via a bonding jumper. The receptacle has a matching grounding pole connected to the sys-tem ground conductor which is further tied to the grounded conduit system via a bonding jumper. Upon insertion, detent springs in the receptacle housing contact and ground the plug housing; then the extra long ground pole connects before the cur-rent carrying poles engage. The Style II ground pole makes first and breaks last.
3W4P Illustrated
3W3P Illustrated
Denotes Patented Feature
Unique VersaMate® Feature The VersaMate Line is designed for the industrial customer based on engineering and user surveys
P
Exclusive O-ring seals
Exclusive O-ring seals
• NEMA 3R Rating: When receptacle cap is snapped shut
• NEMA 4X Rating: When receptacle cap is turned shut or with VersaMate® plug inserted and ring tightened
Allen/Slot type box terminals provide secrue clamping of conductors (200A Version is Patented)
P
Allen/Slot type box terminals provide secrue clamping of conductors (200A Version is Patented)
KILLARK RECEPTACLES
KILLARK VERSAMATE® RECEPTACLES
WWW.HUBBELL-KILLARK.COM R7
30A SELECTION IN FORMATION
30 amp 2
• 30 Amp 600VAC/250VDC; 50-400 Hertz NEMA 3, 4, 4Xj• PLUGS ONLYk: Class I, Div. 1 & 2, Groups B,C,D; NEMA 7 B,C,D Class l, Zones 1 & 2, llB+H2, llA Class ll, Div. 1 & 2, Groups F & G; NEMA 9 F,G; Class lll
C D ReceptacleEConnector
F i l e No . E10757 Wire Range Regular Stranding: #10 - #6 original style or “AT” type (Includes Type P marine) Extra flex: #10 - #8 original style or “AT” type
Plug
Original or AT Terminals.See R5 for more information
Certified File No. LR111846
3 0 A M P R E C E P T A C L E S & B A C K B O X E S
CATALOG NUMBER
*See page R5 for more information on these options.
3116
2316
314223
32
31332
31332 223
32
Plug
Connector
Receptacle
Back Box Dimensions
GROUND STYLE
Sty l e I
S t y l e I I
2W2P
3W3P
4W4P
2W3P
3W4P
VR321E2VR331E2VR341E2VR332E2VR342E2VRE23
VR321C2VR331C2VR341C2VR332C2VR342C2
VRC23
VR321D2VR331D2VR341D2VR332D2VR342D2VRD23
VR321
VR331
VR341
VR332
VR342
–
CIRCUIT El TYPE ORIG. AT
Cl TYPE ORIG. AT
DlTYPE ORIG. AT
RECEPTACLE ONLY ORIG. AT
Splice box onlyl
l30 Amp Back Boxes are available in 1/2”, 3/4” and 1” conduit sizes. Size listed for 3/4”. For other available sizes, change the BOLD “2” in either the assembly or box only number to: 1=1/2”, 2=3/4”, 3=1”. Assembly catalog numbers are listed for ease of ordering or specification and devices are shipped as compo-nents.
Sty l e I
S t y l e I I
2W2P
3W3P
4W4P
2W3P
3W4P
.55 - 1.20 IN
.55 - 1.20 IN
.55 - 1.20 IN
.55 - 1.20 IN
.55 - 1.20 IN
VP3275
VP3375
VP3475
VP3385
VP3485
GROUND STYLE CIRCUIT GROMMET
RANGE PLUG ORIG. AT
VPR3255
VPR3355
VPR3455
VPR3365
VPR3465
CONNECTOR ORIG. AT
VRD
VRC
VRE
jComponents are intermateable & UL classified with other UL1686 config ured devices (when installed in accordance with instructions furnished with device). Assemblies containing components from other manufactur ers would have the NEMA type rating of the lowest rated device.kPlugs are hazardous suitable when mated with properly rated receptacles configured to use UL1686 type plugs, such as VersaMate VSQ/VBQ.– Note, 2, 3 & 4 pole device dimensions are the same.
M O D I F I C A T I O N S *
Reverse service for receptacles, plugs & connectors
Polarizat ion for receptacles, plugs & connectors
S39
S37
CATALOG NUMBER DESCRIPTION
CATALOG NUMBER
VersaMate® clamps provide a firm fit for one plug (or con-nector) over a wide range of cable diameters (competitors often need two – requiring additional sizing decisions).
VP3022
VP3033
VP3044
VP3023
VP3034
VPR3022
VPR3033
VPR3044
VPR3023
VPR3034
VR3022E2VR3033E2VR3044E2VR3023E2VR3034E2
VRE23
VR3022C2VR3033C2VR3044C2VR3023C2VR3034C2
VRC23
VR3022
VR3033
VR3044
VR3023
VR3034
–
VR3022D2VR3033D2VR3044D2VR3023D2VR3034D2
VRD23
FEATURES-SPECIFICATIONS
3 0 A M P P L U G S & C O N N E C T O R S
RETURN to
Index
KILLARK VERSAMATE® RECEPTACLES
R8
60A SELECTION INFORMATION
6 0 A M P P L U G S & C O N N E C T O R S
• 60 Amp 600VAC/250VDC; 50-400 Hertz NEMA 3, 4, 4Xj• PLUGS ONLYk: Class I, Div. 1 & 2, Groups B,C,D; NEMA 7 B,C,D Class l, Zones 1 & 2, llB+H2, llA Class ll, Div. 1 & 2, Groups F & G; NEMA 9 F,G; Class lll
C D ReceptacleEConnector
F i l e No . E10757 Wire Range Regular Stranding: #6 - #2 original style or “AT” type (Includes Type P marine) Extra flex: #6 - #4 original style or “AT” type
Plug
Original or AT Terminals.See R5 for more information
Certified File No. LR111846
Receptacle
Plug
Connector
Back Box Dimensions
jComponents are intermateable & UL classified with other UL1686 config- ured devices (when installed in accordance with instructions furnished with device). Assemblies containing components from other manufacturers would have the NEMA type rating of the lowest rated device.kPlugs are hazardous suitable when mated with properly rated receptacles configured to use UL1686 type plugs, such as VersaMate VSQ/VBQ.mDimensions in ( ) are 3 pole devices; balance are 4 pole.
l60 Amp Back Boxes are available in 1”, 1-1/4” and 1-1/2” conduit sizes. Size listed above is 1-1/4”. For other available sizes, change the BOLD “4” in either the assembly or box only number as follows: 3=1”, 4=1-1/4”, 5=1-1/2”. Assembly catalog numbers are listed for ease of ordering or specification and devices are shipped as components. Note: 60 Amp receptacles also fit 100 Amp mounting boxes – see Notem (100 Amp) on R5.
612
81316
31116 217
32 3(33
8) (214)
�
478
�
VRC
VRE
VRD
*See page R5 for more information on these options.
M O D I F I C A T I O N S *
Reve rse se rv i ce fo r r ecep tac l es , p lugs & connec to rs
Po la r i z a t i on fo r r ecep tac l es , p lugs & connec to rs
S39
S37
CATALOG NUMBER DESCRIPTION
VersaMate® clamps provide a firm fit for one plug (or con-nector) over a wide range of cable diameters (competitors often need two – requiring additional sizing decisions).
m
6 0 A M P R E C E P T A C L E S & B A C K B O X E S
GROUND STYLE
Sty l e I
S t y l e I I
2W2P
3W3P
4W4P
2W3P
3W4P
VR621E4VR631E4VR641E4VR632E4VR642E4VRE46
VR621C4VR631C4VR641C4VR632C4VR642C4
VRC46
VR621D4VR631D4VR641D4VR632D4VR642D4VRD46
VR621
VR631
VR641
VR632
VR642
–
CIRCUIT El TYPE ORIG. AT
Cl TYPE ORIG. AT
DlTYPE ORIG. AT
RECEPTACLE ONLY ORIG. AT
Splice box onlyl
CATALOG NUMBER
VR6022E4VR6033E4VR6044E4VR6023E4VR6034E4
VRE46
VR6022C4VR6033C4VR6044C4VR6023C4VR6034C4
VRC46
VR6022
VR6033
VR6044
VR6023
VR6034
–
VR6022D4VR6033D4VR6044D4VR6023D4VR6034D4
VRD46
CATALOG NUMBER
Sty l e I
S t y l e I I
2W2P
3W3P
4W4P
2W3P
3W4P
.65 - 1.50 IN
.65 - 1.50 IN
.65 - 1.50 IN
.65 - 1.50 IN
.65 - 1.50 IN
VP6275
VP6375
VP6475
VP6385
VP6485
GROUND STYLE CIRCUIT GROMMET
RANGE PLUG ORIG. AT
VPR6255
VPR6355
VPR6455
VPR6365
VPR6465
CONNECTOR ORIG. AT
VP6022
VP6033
VP6044
VP6023
VP6034
VPR6022
VPR6033
VPR6044
VPR6023
VPR6034
FEATURES-SPECIFICATIONS
KILLARK RECEPTACLES
RETURN to
Index
KILLARK VERSAMATE® RECEPTACLES
WWW.HUBBELL-KILLARK.COM R9
100A SELECTION INFORMATION
FEATURES-SPECIFICATIONS
• 100 Amp 600VAC/250VDC; 50-400 Hertz NEMA 3, 4, 4Xj• PLUGS ONLYk: Class I, Div. 1 & 2, Groups B,C,D; NEMA 7 B,C,D Class l, Zones 1 & 2, llB+H2, llA Class ll, Div. 1 & 2, Groups F & G; NEMA 9 F,G; Class lll
E C ReceptacleConnector
F i l e No . E10757 Wire Range Regular Stranding: #4 - #2 original style or “AT” type (Includes Type P marine) Extra flex: #4 - #2 original style or “AT” type
Plug
Original or AT Terminals.See R5 for more information
Certified File No. LR111846
Back Box Dimensions
j Components are intermateable & UL classified with other UL1686 config-ured devices (when installed in accordance with instructions furnished with device). Assemblies containing components from other manufacturers would have the NEMA type rating of the lowest rated device.kPlugs hazardous suitable when mated with properly rated receptacles configured to use UL1686 type plugs, such as VersaMate VBQ.nDimensions in ( ) are 3 pole devices; balance are 4 pole.
* Angle adapter onlyl100 Amp Back Boxes are available in 1”, 1-1/4”, 1-1/2” & 2” conduit sizes. Size listed above is 1-1/2”. For other available sizes, change the BOLD “5” in either the assembly or box only number as follows:3=1”, 4=1-1/4”, 5=1-1/2”, 6=2”. Assembly catalog numbers are listed for ease of ordering or specification and devices are shipped as components.
m100 Amp Boxes & Adapters also fit 60 Amp receptacles. Adapter only can be used to attach receptacle at an angle to a standard sheet metal box.
�
� VJC
*See page R5 for more information on these options.
M O D I F I C A T I O N S *
Reve rse se rv i ce fo r r ecep tac l es , p lugs & connec to rs
Po la r i z a t i on fo r r ecep tac l es , p lugs & connec to rs
S39
S37
CATALOG NUMBER DESCRIPTION
Receptacle
Plug
Connector
n
Feed through style shown
VersaMate® clamps provide a firm fit for one plug (or connector) over a wide range of cable diameters (competitors often need two – requir-ing additional sizing decisions).
CATALOG NUMBER
1 0 0 A M P P L U G S & C O N N E C T O R S
Sty l e I
S t y l e I I
2W2P
3W3P
4W4P
2W3P
3W4P
.88 - 1 .68 IN
.88 - 1 .68 IN
.88 - 1 .68 IN
.88 - 1 .68 IN
.88 - 1 .68 IN
VP10277
VP10377
VP10477
VP10387
VP10487
GROUND STYLE CIRCUIT GROMMET
RANGE PLUG ORIG. AT
VPR10257
VPR10357
VPR10457
VPR10367
VPR10467
CONNECTOR ORIG. AT
VP1022
VP1033
VP1044
VP1023
VP1034
VPR1022
VPR1033
VPR1044
VPR1023
VPR1034
1 0 0 A M P R E C E P T A C L E S & B A C K B O X E S
GROUND STYLE
Sty l e I
S t y l e I I
2W2P
3W3P
4W4P
2W3P
3W4P
VR1021E5VR1031E5VR1041E5VR1032E5VR1042E5
VJ57
VR1021C5VR1031C5VR1041C5VR1032C5VR1042C5
VJC57
VR1021
VR1031
VR1041
VR1032
VR1042
VJA100*
CIRCUIT El TYPE ORIG. AT
ClTYPE ORIG. AT
RECEPTACLE ONLY ORIG. AT
Splice box onlyl
CATALOG NUMBER
VR1022E5VR1033E5VR1044E5VR1023E5VR1034E5
VJ57
VR1022
VR1033
VR1044
VR1023
VR1034
VJA100*
VR1022C5VR1033C5VR1044C5VR1023C5VR1034C5
VJC57
RETURN to
Index
KILLARK VERSAMATE® RECEPTACLES
R10
150A SELECTION INFORMATION
FEATURES-SPECIFICATIONS
• 150 Amp 600VAC/250VDC; 50-400 Hertz NEMA 3, 4, 4X
E C Receptacle
F i l e No . E10757 Wire Range Building #2-2/0 (Includes Type P marine) Extra Flex #2-2/0
Pending
KILLARK RECEPTACLES
ALLENTERMINALSNEW!
ConnectorPlug
Back Box Dimensions
j Components are intermateable & UL classified with Appleton® Powertite® (when installed in accordance with instructions furnished with device). Assemblies containing components from other manufacturers would have the NEMA type rating of the lowest rated device.
* Angle adapter onlyl150 Amp Back Boxes are available in 1-1/4”, 1-1/2” & 2” conduit sizes. Size listed above is 2”. For other available sizes, change the BOLD “6” in either the assembly or box only number as follows: 4=1-1/4”, 5=1-1/2”, 6=2”. Assembly catalog numbers are listed for ease of ordering or specification and devices are shipped as components. m100/150 Amp Boxes & Adapters also fit 60 Amp receptacles. Adapter only can be used to attach receptacle at an angle to a standard sheet metal box.
�
� VJC
*See page R5 for more information on these options.
M O D I F I C A T I O N S *
Reverse service for receptacles, plugs & connectors
Po la r i z a t i on fo r r ecep tac l es , p lugs & connec to rs
S39
S37
CATALOG NUMBER DESCRIPTION
Receptacle
Plug
ConnectorFeed through style shown
VersaMate® clamps provide a firm fit for one plug (or connector) over a wide range of cable diameters (competitors often need two – requir-ing additional sizing decisions).
CATALOG NUMBER
1 5 0 A M P P L U G S & C O N N E C T O R S
4W4P
3W4P
Sty l e I
S t y l e I I S t y l e I
S t y l e I I
. 88 - 1 .91 IN
.88 - 1 .91 INVPA15044
VPA15034
GROUND STYLE CIRCUIT GROMMET
RANGE PLUG
VCA15044
VCA15034
CONNECTOR
1 5 0 A M P R E C E P T A C L E S & B A C K B O X E S
GROUND STYLE
4W4P
3W4P
VRA15044E6VRA15034E6
VJ67
VRA15044C6VRA15034C6
VJC67
VRA15044
VRA15034
VJA100*
CIRCUITE TYPE C TYPE RECEPTACLE
ONLY
Sp l i ce box on ly w /adap te rlm
CATALOG NUMBER
RETURN to
Index
KILLARK VERSAMATE® RECEPTACLES
WWW.HUBBELL-KILLARK.COM R11
200A SELECTION INFORMATION
FEATURES-SPECIFICATIONS
• 200 Amp 600VAC/250VDC; 50-400 Hertz NEMA 3, 4, 4Xj
E C ReceptacleConnector
File No. E10757
Wire Range Regular Stranding: #1 - 250 (Includes Type P marine Extra flex: #1 - 250 (.653 max conductor diameter) Certified File No. LR111846
Plug
ALLENTERMINALS
Receptacle
Connector
Back Box Dimensions
Sty l e I
S t y l e I I
3W3P
4W4P
2W3P
3W4P
1 .0 - 2 .5 IN
1 .0 - 2 .5 IN
1 .0 - 2 .5 IN
1 .0 - 2 .5 IN
VP203512
VP204513
VP203612
VP204612
GROUND STYLE CIRCUIT GROMMET
RANGE PLUG CATALOG NUMBER
VPR203112
VPR204113
VPR203212
VPR204212
CONNECTOR
j Components are intermateable & UL classified with Appleton® Powertite® or Crouse-Hinds® Arktite® devices (when installed in accordance with instructions furnished with device. Assemblies con taining components from other manufacturers would have the NEMA type rating of the lowest rated device.
m Dimensions in ( ) are 3 pole devices; balance are 4 pole.
n 200A 3W4P Reverse Service configured “W” Series and VersaMate® are not intermateable. However, the VersaMate VR20422-S39 recepta- cle ships with instructions to permanently convert for use with existing PW-6402X SU39 plugs. Factory only configured plugs to fit old RW64C- SU39 receptacles may be ordered as VP-PW64026 SU39.
200 Amp Back Boxes are available in dead-end sizes 1-1/2”, 2” & 2-1/2” conduit sizes. Dead-end box shown is 2”. For other available dead-end box sizes, change the BOLD “6” in either the dead-end assembly or box only number as follows: 5=1-1/2”, 6=2”, 7=2-1/2”. Feed through boxes are available in 2-1/2”; use “R” series adapters as required for smaller sizes (sold separately). Assembly catalog numbers are listed for ease of ordering or specification and devices are shipped as components.
Adapter only can be used to attach receptacle at an angle to a standard sheet metal box.
NOTE: 200A VersaMate receptacle lids secure with wingnuts for N4X environ-ments when not in use. VersaMate plugs secure with wingnuts and/or lock-ring collar. This exclusive dual method allows retention of competi-tive plugs that use either wingnuts or a lock-ring collar.
VJC
*See page R5 for more information on these options.
M O D I F I C A T I O N S *
Reve rse se rv i ce fo r r ecep tac l es , p lugs & connec to rs
Po la r i z a t i on fo r r ecep tac l es , p lugs & connec to rs S39n
S37
CATALOG NUMBER DESCRIPTION
2 0 0 A M P R E C E P T A C L E S & B A C K B O X E S
GROUND STYLE
Sty l e I
S t y l e I I
3W3P
4W4P
2W3P
3W4P
VR20312E6VR20412E6VR20322E6VR20422E6
VJ68
VR20312C7VR20412C7VR20322C7VR20422C7
VJC78
VR20312
VR20412
VR20322
VR20422
Ang le adap te ron ly VJA200
CIRCUIT EkTYPE
CkTYPE
RECEPTACLE ONLY
Sp l i ce box on ly w /adap te rkl
CATALOG NUMBER
VersaMate®
clamps provide a firm fit for one plug (or connector) over a wide range of cable diameters (competitors often need two – requir-ing additional sizing decisions).
Plug
k
l
m
2 0 0 A M P P L U G S & C O N N E C T O R S
RETURN to
Index
V S Q & V W S Q R E C E P T A C L E S
KILLARK VERSAMATE® RECEPTACLES
KILLARK RECEPTACLESR12
VSQ SWITCHED RECEPTACLES
• VSQ Hazardous Location Ratings Class I, Div. 1 & 2, Groups B,C,D Class I, Zones I & 2, Groups IIB+H2, IIA Class II, Div. 1 & 2, Groups F & G Class lll NEMA 3, 4, 4X, 7 (B,C,D), 9 (F,G)
VersaMate VSQ & VWSQ Receptacles use VersaMate Style II plugs found on pages PR6 & PR7 and are compatible with appropriately configured Crouse-Hinds® Arktite® or Appleton® Powertite® plugs (when installed in accordance with instructions fur-nished with device)
Arktite® is a registered trademark of Crouse-Hinds®.
Powertite® is a registered trademark of Appleton®.
Features• N4X with receptacle lid turned shut or
with plug locking ring tightened • Copper-free aluminum construction
with electrostatically applied polyes-ter/epoxy finish. Handle mechanism is chemical resistant Valox®
(TM General Electric).
• Compact size and footprint• Plug Interlock Mechanism for Dead-
front construction. Switch cannot be turned “ON” without fully inserted plug. Plug cannot be removed with switch in “ON” position
• Plug held in place when switch is “Off” for convenience. Pull operated release mechanism. Plug and wiring do not have to be twisted or held to operate switch
• Factory Wired Receptacle; easy to wire line side of switch
• Easily visible “On-Off” indicator handle
• “Off” position is padlockable for maintenance safety
HORSEPOWER 120 240 480 600RATINGS (VAC)j
1Ø 2 5 10 15
3Ø 3 7.5 15 20
1Ø – 10 15 20
3Ø – 10 25 30
30A
60A
NOTES: VSQ/VWSQ 30 Amp models come standard with 1” drilled and tapped conduit openings top and bottom plus two 1” x 3/4” reducers and one 3/4” close-up plug for maximum flexibility.
60 amp models come with 1-1/2” openings top and bottom and one 1-1/2” close-up plug.
VSQ & VWSQ Receptacle covers are NOT interchangeable.
jRefers to internal switch only.
CATALOG NUMBERAMPS CIRCUIT
*See page R5 for more information on this option
M O D I F I C A T I O N S *
Po la r i z a t i on fo r r ecep tac l es , p lugs
S37
CATALOG NUMBER DESCRIPTION
F i l e No . LR14667
F i l e No . E216488
• VWSQ for Wet & Corrosive Locations NEMA 3, 4, 4X
Wire Range30 Amp Regu la r S t r and ing Max #1060 Amp Regu la r S t r and ing Max #4
Dimensions shown are in inches for 30 AMP: 60 Amp dimensions in ( ). NOTES: Devices have adjustable ductile lugs (vertical or side) for attachment to uneven surfaces. Ordinary twist type wire connectors are used for final connections on 30A, 60A devices have terminal blocks.
Dimensions
VSQ
VWSQ
FEATURES-SPECIFICATIONS
• Auxiliary Contact (late-make early-break) contact rated 10 Amp, 1/3 HP at 125/250 VAC. Can be used for operating pilot lights or starter coils (standard model only)
• Feed-through construction• Horsepower Rated • Internal switch horsepower rated as “motor disconnect”
VSQ HAZARDOUS VWSQ N4X ONLY VERSAMATE PLUG
30
2W3P VSQ3023 VWSQ3023 VP3385
3W4P VSQ3034 VWSQ3034 VP3485
60
2W3P VSQ6023 VWSQ6023 VP6385
3W4P VSQ6034 VWSQ6034 VP6485
RETURN to
Index
FACTORY SEALED SOLUTION
KILLARK VERSAMATE® RECEPTACLES
WWW.HUBBELL-KILLARK.COM R13
VSQ -FS FACTORY SEALED
Class I, Div. 1 & 2, Groups B,C,DClass I, Zones I & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F & G Class lllNEMA 3, 4, 4X, 7 (B,C,D), 9 (F,G)
Dimensions shown are in inches for 30 AMP. 60 AMP Dimensions in ( ).
Features – same as VSQj plus:• Factory Sealed Construction elimi-
nates need for conduit sealing at the device
• Saves Installation Time & Labor – facilitates rework
• Switch has factory wired line and load terminals. Load terminals feed sealed receptacle as in a standard VSQ. Line wiring is passed from the sealed compartment into the wiring chamber
• Receptacles may be loosened from black box and turned 180 degrees to adjust for top or bottom feed.
• Ordinary twist type wire connec-tors are used for final connections on 30A. 60A devices have terminal blocks
NOTES: VSQ-FS 30 Amp models come standard with one 1” drilled and tapped conduit open-ings into the wiring chamber plus one 1” x 3/4” reducer.
60 amp models come with one 1” opening. jVSQ-FS models do not have auxiliary contacts.
VSQ-FS VERSAMATE HAZARDOUS PLUG
30 2W3P VSQ3023FS VP3385
30 3W4P VSQ3034FS VP3485
60 2W3P VSQ6023FS VP6385
60 3W4P VSQ6034FS VP6485
V S Q - F S R E C E P T A C L E S
Dimensions
*See page R5 for more information on this option.
M O D I F I C A T I O N S *
Polar iza t ion for receptac les & plugs S37
CATALOG NUMBER DESCRIPTION
CATALOG NUMBERAMPS CIRCUIT
Cer t i f i ed F i l e No . LR14667
Wire Range30 Amp Regu la r S t r and ing Max #1060 Amp Regu la r S t r and ing Max #4
FEATURES-SPECIFICATIONS
EXCLUSIVE
RETURN to
Index
KILLARK VERSAMATE® RECEPTACLES
KILLARK RECEPTACLESR14
VBQ BREAKER PROTECTED
VersaMate VBQ Receptacles use VersaMate Style II plugs found on 30, 60 and 100 amp pages and are compatible with appropriately configured Crouse-Hinds® Arktite® or Appleton® Powertite® plugs (when installed in accordance with instruc-tions furnished with device).
Arktite® is a registered trademark of Crouse-Hinds®.
Powertite® is a registered trademark of Appleton®.
FeaturesReceptacle:• N4X with receptacle lid turned shut
or with plug locking ring tightened• Plug held in place when switch is
“Off” for convenience. Pull button operated release mechanism. Plug does not have to be twisted to oper-ate switch
• Dead-front construction when recep-tacle is off. Switch cannot be turned “ON” without fully inserted plug. Plug cannot be removed with switch in “ON” position
• Wire Connections do not bend when opening and closing door – minimizes loosening during installation or maintenance procedures
• For ground fault option, contact factory
Dimensions
Enclosure:• Spacious wiring room. Meets the
latest NEC wire bending require-ments for circuit breaker enclosures
• Ductile Mounting Lugs to adjust to uneven surfaces
• Copper-free construction with 316 grade Stainless Steel External Hardware
• Quick Release Cover Bolts with Triple Leads – only 3-1/2 turns to disengage
• Recessed Flange Notches – Allows easier cover opening with prying instrument without flange damage
• Electrostatically applied polyester/epoxy finish
• Visible “ON” external Breaker Handle has provisions for locking “ON” or “OFF” with up to three Padlocks
• Internal Lock-Off provision for main-tenance when no hazardous materi-als are present
3
3
334
�12
Replacement Parts:• Enclosure gasket VBQ-535 • External handle kit CBHK-100H
See instruction sheet included with device for other available replace-ment parts.
FEATURES-SPECIFICATIONS
F i l e No . E184637
Receptacle assembly is field replaceable for maintenance.
Ordering information listed in the instruction sheets provided with the product.
Class I, Div. 1 & 2, Groups B,C,DClass I, Zones I & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F & G Class lllNEMA 3, 4, 4X, 7 (B,C,D), 9 (F,G)
RETURN to
Index
SQUARE D SQUARE D CUTLER-HAMMER CUTLER-HAMMER VERSAMATE FAL (480 VAC MAX.) FHL (600 VAC MAX.) EHD (480 VAC MAX.) FD (600 VAC MAX.) PLUG 20 VBQ3023SN20 VBQ3023SH20 VBQ3023CN20 VBQ3023CH20 VP3385 30 VBQ3023SN30 VBQ3023SH30 VBQ3023CN30 VBQ3023CH30 VP3385 2W3P 40 VBQ3023SN40 VBQ3023SH40 VBQ3023CN40 VBQ3023CH40 VP3385 30 50 VBQ3023SN50 VBQ3023SH50 VBQ3023CN50 VBQ3023CH50 VP3385 20 VBQ3034SN20 VBQ3034SH20 VBQ3034CN20 VBQ3034CH20 VP3485 30 VBQ3034SN30 VBQ3034SH30 VBQ3034CN30 VBQ3034CH30 VP3485 3W4P 40 VBQ3034SN40 VBQ3034SH40 VBQ3034CN40 VBQ3034CH40 VP3485 50 VBQ3034SN50 VBQ3034SH50 VBQ3034CN50 VBQ3034CH50 VP3485 50 VBQ6023SN50 VBQ6023SH50 VBQ6023CN50 VBQ6023CH50 VP6385 60 VBQ6023SN60 VBQ6023SH60 VBQ6023CN60 VBQ6023CH60 VP6385 2W3P 70 VBQ6023SN70 VBQ6023SH70 VBQ6023CN70 VBQ6023CH70 VP6385 90 VBQ6023SN90 VBQ6023SH90 VBQ6023CN90 VBQ6023CH90 VP6385 100 VBQ6023SN100 VBQ6023SH100 VBQ6023CN100 VBQ6023CH100 VP6385 60 50 VBQ6034SN50 VBQ6034SH50 VBQ6034CN50 VBQ6034CH50 VP6485 60 VBQ6034SN60 VBQ6034SH60 VBQ6034CN60 VBQ6034CH60 VP6485 3W4P 70 VBQ6034SN70 VBQ6034SH70 VBQ6034CN70 VBQ6034CH70 VP6485 90 VBQ6034SN90 VBQ6034SH90 VBQ6034CN90 VBQ6034CH90 VP6485 100 VBQ6034SN100 VBQ6034SH100 VBQ6034CN100 VBQ6034CH100 VP6485 50 VBQ1023SN50 VBQ1023SH50 VBQ1023CN50 VBQ1023CH50 VP10387 70 VBQ1023SN70 VBQ1023SH70 VBQ1023CN70 VBQ1023CH70 VP10387 2W3P 90 VBQ1023SN90 VBQ1023SH90 VBQ1023CN90 VBQ1023CH90 VP10387 100 VBQ1023SN100 VBQ1023SH100 VBQ1023CN100 VBQ1023CH100 VP10387 100 50 VBQ1034SN50 VBQ1034SH50 VBQ1034CN50 VBQ1034CH50 VP10487 70 VBQ1034SN70 VBQ1034SH70 VBQ1034CN70 VBQ1034CH70 VP10487 3W4P 90 VBQ1034SN90 VBQ1034SH90 VBQ1034CN90 VBQ1034CH90 VP10487 100 VBQ1034SN100 VBQ1034SH100 VBQ1034CN100 VBQ1034CH100 VP10487
KILLARK VERSAMATE® RECEPTACLES
WWW.HUBBELL-KILLARK.COM R15
VBQ BREAKER PROTECTED
Internal Lock-Offprovision formaintenance whenno hazardousmaterials are present
Ci rcu i t B reake r Wi re Range
Squa re D To 30 Amp #14-4 cu . ; 35-100 Amp #14-1 /0 cu .
Cu t l e r -Hammer To 20 Amp #14-10 cu . ; 30-100 Amp #14-1 /0 cu .
Consult Breaker Manufacturer literature for Horsepower Ratings.
†DC ra t i ngs app ly t o subs tan t i a l l y non- induc t i ve c i r cu i t s .
CATALOG NUMBER
M O D I F I C A T I O N Sj
Polar i za t ion fo r recep tac les & p lugsDra in
Brea the r
Dra in and B rea the r (CSA Groups C & D)
S37
SU10
SU11
SU3
CATALOG NUMBER DESCRIPTION
jSee page R5 and price sheet for more information on these options.
F i l e No . E184637
Class I, Div. 1 & 2, Groups B,C,DClass I, Zones I & 2, IIB+H2, IIAClass II, Div. 1 & 2, Groups F & G Class lllNEMA 3, 4, 4X, 7 (B,C,D), 9 (F,G)
Ci rcu i t B reake r 208/240 480 VAC 600 VAC 250 VDC†In t e r rup t ing Ra t ings VAC
Squa re D FAL 25 ,000 18 ,000 —— 10 ,000
Squa re D FHL 65 ,000 25 ,000 18 ,000 10 ,000
Cu t l e r -Hammer EHD 18 ,000 14 ,000 —— 10 ,000
Cu t l e r -Hammer FD 65 ,000 25 ,000 18 ,000 10 ,000
RECEPTACLE CIRCUIT BREAKER
FEATURES-SPECIFICATIONS
V B Q R E C E P T A C L E S
Contact factory for VBQ with ground fault option
ACCEPTOR ® RECEPTACLES
EXCLUSIVE QUICK WIRING PLUG
Old style insulator requires miniture screwdriver
Single piece shell for fewer parts
Built-in wirestrip gauge
Wire guides enables easy conductor installation
Side tighting terminals use full sized #2 screwdriver (either flat or Phillips)
UGPQW Plug
Insulator fits one way only
Centered cable grip
KILLARK ACCEPTOR® RECEPTACLES
WWW.HUBBELL-KILLARK.COM R17
UGR/UGP BLADED RECEPTACLES
FEATURES-SPECIFICATIONS
The ACCEPTOR® UGP/UGR Plug and Receptacle system, with its unique, patented design, is interchange-ablej with other NEMA bladed type explosion-proof and dust ignition proof devices. The series has been tested and classified for use with Crouse-Hinds® Ark-Gard®2 and Appleton® U-Line® plugs and receptacles in hazardous locations.j No w available in GFCI versions. See pages R21-R22 How The Acceptor System WorksACCEPTOR receptacles contain an integral switch which must be closed to energize the circuit. The design permits only an approved plug to be energized. To actuate the switch, the plug must be inserted and rotated clockwise approximately 45o. The plug will lock into this position preventing accidental disengagement. To remove, simply push in then turn the plug coun-terclockwise and pull straight out.Plugs and receptacles may be used where interchangeable bladed devices are needed in locations made hazard-ous by the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers and flyings.Plug can serve to provide power for portable equipment used in both hazardous and non-hazardous areas.
Applications• Petroleum Refineries, Chemical Plants• Wet/Damp/Corrosive Areas• Grain Elevators/Feed Mills
Features• All external hardware is 316 stainless steel
to provide low maintenance and long life• Factory sealed chamber in UGR recep-
tacle contains switch’s arcing components• No additional external seals are required,
except in Group B applications
Class I, Div. 1 & 2, Groups Bk,C,DClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F,GClass IIINEMA 3, 7 (B,C,D), 9 (F,G)
L is t ed F i l e No . E91049 and/o r E53660
Cer t i f i ed F i l e No . LR14667
• Receptacles are U.L. Listed as raintight. Proper sealing against moisture is assured
• Spring loaded receptacle cover closes when plug is removed to provide protection when not in use
• Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion
• Electrostatically applied and baked powder epoxy/polyester finish
PLUGACCEPTOR® plugs conform to NEMA configurations and can be used with standard receptacles in non-hazardous areas to maximize equipment utilization. The system’s “turn to engage” feature
1.51" 1.69"
2.55"
kPlugs Rated Group B when used with properly rated & installed receptacles. See next page.
1/4"
45/8"
3"
j Exact models classified for interchangeability are listed in the information sheet provided with the products. Ark-Gard® is a registered trademark of Crouse-Hinds®. U-Line® is a registered trademark of Appleton Electric Company®.
UGP-15231 UGP-15231QW
UGP-15232 UGP-15232QW
NEMA CONFIGURATION
locks in plug and can be used to pre-vent accidental disengagement of critical equipment. Plugs for use with type S, SO, ST or STO heavy duty cord.
15 AMP PLUGW/QUICK WIRING
15 AMP PLUG
CATALOG NUMBER
20 AMP PLUGW/QUICK WIRING
20 AMP PLUG
CATALOG NUMBER
UGP-20231 UGP-20231QW
UGP-20232 UGP-20232QW
NEMA CONFIGURATIONVOLTAGE
125VAC
250VAC
NEW!
UGPQW PlugUGR Receptacle
QWQuick Wiring Plug
• Single piece shell for fewer parts• Transparent wiring entrance holes for
easy conductor insertion• Screws tighten from side with “full sized”
screwdriver• Insulator fits "one way"• Centered cable grip
EXCLUSIVE QUICK WIRING PLUG
Single piece shell for fewer parts
QUICK WIRING
PLUG43/16"
4 5/8"
15/8"
60O
6"
RETURN to
Index
KILLARK ACCEPTOR® RECEPTACLES
KILLARK RECEPTACLESR18
UGRC SELECTION INFORMATION
R E C E P T A C L E S A N D A S S E M B L I E Sm
—
1/2”
3/4”
1”
1 /2”
3 /4”
1”
—
1/2”
3 /4”
1”
1 /2”
3 /4”
1”
HUB SIZE
RECEPTACLE ONLY
DEAD END
FEED-THRU
RECEPTACLE ONLY
DEAD END
FEED-THRU
ENCLOSURESTYLE
NEMA RATING& CONFIGURATION
j Items in this column are suitable for Class I, Group B in addition to Class I, Groups C, D. Also suitable for Class I, Zone 1, Groups IIB+H2, IIA.k Seals must be installed within 6 inches of conduit opening.l Items in this column may also be used in Class I, Zone 1, Groups IIB, IIA.
Assembly numbers not rated for Group B are shipped as receptacle & back box components. m Refer to Killark catalog for additional SWB Series Back Box configurations.n Canada only configurationoCanadian Codes now allow “T” combination slots for 15A or 20A plugs. Check breaker and wire feed size for proper application ratings.NOTE: For replacement receptacle cover and hinge, order KIT-173.
2 POLE
3 WIRE
2 POLE
3 WIRE
—
1/2”
3 /4”
1”
1 /2”
3 /4”
1”
RECEPTACLE ONLY
DEAD END
FEED-THRU
2 POLE
3 WIRE
—
1/2”
3 /4”
1”
1 /2”
3 /4”
1”
RECEPTACLE ONLY
DEAD END
FEED-THRU
2 POLE
3 WIRE
20 Amp125 Volt
15 Amp125 Volt
5-20R
5-15R
15 Amp250 Volt
6-15R
20 Amp250 Volt
6-20R
UGRO-20231
UGR7-20231
UGR8-20231
UGR9-20231
UGR10-20231
UGR11-20231
UGR12-20231
UGROC-15231
UGR7C-15231
UGR8C-15231
UGR9C-15231
UGR10C-15231
UGR11C-15231
UGR12C-15231
UGRO-20232
UGR7-20232
UGR8-20232
UGR9-20232
UGR10-20232
UGR11-20232
UGR12-20232UGROC-15232
UGR7C-15232
UGR8C-15232
UGR9C-15232
UGR10C-15232
UGR11C-15232
UGR12C-15232
UGRO-20231
UGR1-20231
UGR2-20231
UGR3-20231
UGR4-20231
UGR5-20231
UGR6-20231
UGROC-15231
UGR1C-15231
UGR2C-15231
UGR3C-15231
UGR4C-15231
UGR5C-15231
UGR6C-15231
UGRO-20232
UGR1-20232
UGR2-20232
UGR3-20232
UGR4-20232
UGR5-20232
UGR6-20232UGROC-15232
UGR1C-15232
UGR2C-15232
UGR3C-15232
UGR4C-15232
UGR5C-15232
UGR6C-15232
—
UGRB1-20231
UGRB2-20231
UGRB3-20231
UGRB4-20231
UGRB5-20231
UGRB6-20231
—
UGRB1C-15231
UGRB2C-15231
UGRB3C-15231
UGRB4C-15231
UGRB5C-15231
UGRB6C-15231
—
UGRB1-20232
UGRB2-20232
UGRB3-20232
UGRB4-20232
UGRB5-20232
UGRB6-20232—
UGRB1C-15232
UGRB2C-15232
UGRB3C-15232
UGRB4C-15232
UGRB5C-15232
UGRB6C-15232
SINGLE GANGjkGROUPS B, C, D, F & G
SINGLE GANGlmGROUPS C, D, F, & G
DOUBLE GANGlmGROUPS C D, F, & G
SWB-1, 2, 3 SWB-4, 5, 6 Single Gang Double Gang
n
o
n
o
FEATURES-SPECIFICATIONS
KILLARK ACCEPTOR® RECEPTACLES
WWW.HUBBELL-KILLARK.COM R19
UGRC CONNECTORS
FEATURES-SPECIFICATIONS
NEMA CONFIGURATION CATALOG NUMBER WEATHER RATING125V CONNECTOR CAP STYLE
250V CONNECTOR CAP STYLE
20 Amp125 Volt
2 POLE3 WIRE
20 Amp250 Volt
2 POLE3 WIRE
6-20R with T-slots
Breech-Lock with Notch Flip Type
5-20R with T-slots
Breech-Lock with Notch Flip Type
Killark 250V Plugs20 Amp15 Amp
Killark 125V Plugs20 Amp15 Amp
UGRC-20231BUGRC-20231F
lUGP-20231QWUGP-15231QW
UGRC-20232BUGRC-20232F
lUGP-20232QWUGP-15232QW
N4X*N3**
N4X*N3**
Connector with Breech-Lock Cap “3rd Hand” Plug Operation
Class I, Div. 1 & 2, Groups B,C,DjClass I, Zones 1 & 2, Groups IIB+H2, IIAjClass II, Div. 1 & 2, Groups F,GkClass IIINEMA 3, 4X*
Cer t i f ied F i le No. LR14667
UGRC ConnectorBreech cap model shown, Flip cap model dimensions are
similar
CONNECTORSThe ACCEPTOR® UGRC Connector complements UGP/UGR Plugs and Receptacles, as well as Ground Fault Protected UGFI and UGRGF Models. Used with Acceptor plugs, connectors can extend the reach for hazardous location rated portable equipment such as hand lamps. Connectors eliminate the need for user created corded box mounted receptacles. UGRC Connectors are interchangeable and classified for use with other NEMA bladed type explosion-proof and dust ignition proof plugs, including Crouse-Hinds® Ark-Gard®2 and Appleton® ULine®. Features• Available with the exclusive Breech-Lock
Cap (see R5 for more info) - patented notch provides “3rd hand” plug operation (holds lid open while one hand operates plug, and other holds connector).
• Factory Sealed Construction • Suitable for 14 or 12 gauge SOOW or
similar cable • Copper-free aluminum (less than 4/10 of
1%) alloy resists corrosion • Electrostatically applied and baked pow-
der epoxy/polyester finish • Dead Front Construction with integral
switch - requires Hazardous Rated NEMA Bladed plug for operation
Ark-Gard® is a registered trademark of Crouse-Hinds® U-Line® is a registered trademark of Appleton Electric Company®
Industrial Applications• Petroleum Refineries • Chemical/Petrochemical Plants • Oil Rigs & Platforms • Wet/Corrosive Environments • Grain Elevators
Dimensions
j
k
Connector shown with Acceptor UGRP receptacle mounted in explosion proof Quantum® enclosure
8.25
2.883.69
*Breech cap models N4X with lid closed and turned, N3 When Plug inserted Hinge Up**Flip Lid models N3 with hinge in UP position with or without plugReplacement Cap and Hinge Kits: Breech KIT-173B, Flip KIT-173 jCSA certified Class I Div.I for Canada and/or other jurisditions accepting CSA.kCCSAUS Class II, Groups F & G for US and Canada.lRemove QW in catalog number for Standard Wiring type plug.
Flip Cap
Cer t i f ied F i le No. LR14667
UGP Plug
RETURN to
Index
KILLARK ACCEPTOR® RECEPTACLES
KILLARK RECEPTACLESR20
UGRP PANEL RECEPTACLES
FEATURES-SPECIFICATIONS
* UGRP Receptacles are available “Factory Installed” in the following series:Enclosures - Series EXB, B7E Distribution Equipment-Series D2L, B7L Lighting Panelboards* Contact factory for ordering information
Class I, Div. 1 & 2, Groups B,C,DjClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F,GClass IIINEMA 3, 4X*
Cer t i f i ed F i l e No .
LR14667kC US
Typical InstallationBreech Cap Model
Typical CLI Div. Iapplication
Typical CLI Div. 2application2-3/8” K.O.
Breech Caps
Flip Lids
*Breech cap models N4X with lid closed and turned, N3 When Plug inserted Hinge Up **Flip Lid models N3 with hinge in UP position with or without plug ***See R17 for Plug NEMA Diagram and DimensionsReplacement Cap and Hinge Kits: Breech KIT-173B, Flip KIT-173jClass I Div.1 B,C,D in enclosures certified to 325 explosive PSI (2”-11½ NPSM threads). Class I Div. 2 in standard location enclosures using only non-arcing components.kcCSAus Certified for United States, Canada, and other jurisdictions accepting the mark.lRemove QW in catalog number for Standard Wiring type plug.
NEMA CONFIGURATION CATALOG NUMBER WEATHER RATING125V PANEL RECEPTACLE CAP STYLE
250V PANEL RECEPTACLE CAP STYLE
20 Amp125 Volt2 POLE3 WIRE
6-20R with T-slots
Breech-Lock with Notch Flip Type
5-20R with T-slots
Breech-Lock with Notch Flip Type
Killark 250V Plugs***20 Amp15 Amp
Killark 125V Plugs***20 Amp15 Amp
UGRP-20231BUGRP-20231F
lUGP-20231QWUGP-15231QW
UGRP-20232BUGRP-20232F
lUGP-20232QWUGP-15232QW
N4X*N3**
N4X*N3**20 Amp
250 Volt2 POLE3 WIRE
Flip Cap
Breech Cap model shown.Flip Cap model dimensions are similar
PANEL RECEPTACLES The ACCEPTOR® UGRP Panel Receptacle complements UGP/UGR Plugs and Receptacles, as well as Ground Fault Protected UGFI and UGRGF Models. Used with Acceptor plugs, panel recep-tacles provide local power for hazardous location rated portable equipment such as hand lamps. Units are suitable for Class I Div. 1 or Class I Div.2 depending on the enclosure type usedj. UGRP Panel Receptacles are inter-changeable and classified for use with other NEMA bladed type explosion-proof and dust ignition proof plugs, includ-ing Crouse-Hinds® Ark-Gard®2 and Appleton® ULine®.
Features• Available with the exclusive Breech-Lock
Cap (see R5 for more info) - patented notch provides “3rd hand” plug opera-tion (holds lid open while one hand operates plug, and other holds connector).
• Factory Sealed Construction • Copper-free aluminum (less than 4/10 of
1%) alloy resists corrosion • Electrostatically applied and baked
powder epoxy/polyester finish • Dead Front Construction with integral
switch - requires Hazardous Rated NEMA Bladed plug for operation
Ark-Gard® is a registered trademark of Crouse-Hinds® U-Line® is a registered trademark of Appleton Electric Company®
Industrial Applications• Petroleum Refineries • Chemical/Petrochemical Plants • Oil Rigs & Platforms • Wet/Corrosive Environments • Grain Elevators
Breech Lid
Dimensions4.50
3.692.94
RETURN to
Index
UGRS RECEPTACLE & BACKBOXESj
KILLARK ACCEPTOR® RECEPTACLES
WWW.HUBBELL-KILLARK.COM R21
UGRS/UGRGF RECEPTACLES
FEATURES-SPECIFICATIONS
UGRGFNEW!
NEMA CONFIGURATION CATALOG NUMBER125V SQUARE RECEPTACLE CAP STYLE
250V SQUARE RECEPTACLE CAP STYLE
20 Amp125 Volt2 POLE3 WIRE
6-20R with T-slots
Breech-Lock with Notch* Flip Lid Type**
5-20R with T-slots
Breech-Lock with Notch* Flip Lid Type**
Killark 250V Plugs***20 Amp15 Amp
Killark 125V Plugs***20 Amp15 Amp
UGRS-20231BUGRS-20231F
UGP-20231QWUGP-15231QW
UGRS-20232BUGRS-20232F
UGP-20232QWUGP-15232QW
*Breech cap models N4X with lid closed and turned, N3 When Plug inserted Hinge Up**Flip Lid models N3 with hinge in UP position with or without plug***See R17 for Plug NEMA Diagram and Dimensions
20 Amp250 Volt2 POLE3 WIRE
C D ReceptacleE
Flip Cap
Class I, Div. 2, Groups B,C,DClass I, Zone 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F,GClass IIINEMA 3, 4X
Pend ing
Pend ing
SQUARE RECEPTACLEUGRS Receptacles utilize VERSAMATE® 30A mounting boxes and are designed to provide "ROTATABLE" configurations enabling cover hinge location to be in most convenient position for application. May also be utilized with sheet metal enclosures.
Features• Factory Sealed • Test and Reset push buttons are provided on cover assembly, with optional pilot light availablej Unit should be tested monthly• Includes new GFCI to meet latest
UL943 GFCI standards revisions• Exterior gasket provides NEMA 3
weatherproof protection• Ground boss for grounding in the
splice box• Color coded wiring and stainless steel
cover bolts• Receptacle used is UGRO-20231.
See page PR23
Class I, Div. 1 & 2, Groups C,DClass l, Zones 1 & 2, Groups llB,llAClass lI, Div. 1 & 2, Groups F,GClass IIINEMA 3, 7(C,D) 9(F,G)
Cer t i f i ed LR11714
See f i l es fo r de ta i l s o r ca l l K i l l a rk .
jFor Red LED pi lot l ight ind icator of l ive
c i rcu i t , add “-PL” to cata log number.
Example - UGRGF107-PL.
GFI PROTECTED RECEPTACLE Utilizes FXS GFI and ACCEPTOR®
receptacle to interrupt a circuit, when a ground fault is detected on equipment which may be handled by personnel in hazardous locations.
Electrical RatingGFI units are rated at 20A, 120 VAC, 60Hz. Class A.4-6 miliamp trip settingTrip Time-UL Curve
20A, 125V,
2P, 3W
ENCLOSURESTYLEDead EndDead EndDead EndFeed ThruFeed ThruFeed Thru
HUBSIZE1/2”3/4”1”1/2”3/4”1”
CATALOGNUMBERUGRGF107UGRGF108UGRGF109UGRGF110UGRGF111UGRGF112
NEMA RATING &CONFIGURATION
E Type k C Type k D Type k RECEPT ONLY
20A 125V UGRS-20231BE2 UGRS-20231BC2 UGRS-20231BD2 UGRS-20231B
20A 250V UGRS-20232BE3 UGRS-20232BC3 UGRS-20232BD3 UGRS-20232B
j Receptacles listed are with Breech cap; for Flip Cover change B to F.k Boxes listed are for 3/4"; for 1/2" change last digit to 2, for 1" change last digit to 3.
Breech Cap model shown.Flip Cap model dimensions are similar
Dimensions
RETURN to
Index
G F C I R E C E P T A C L E A D A P T E R ( W / C O R D S E T )
KILLARK ACCEPTOR® RECEPTACLES
KILLARK RECEPTACLESR22
UGFI GROUND FAULT PROTECTOR
NEW!2P 250V GFI
1/2” HUB UGFI202C3
3/4” HUB UGFI202C3
1” HUB UGFI202C3
1/2” HUB UGFI152C3
3/4” HUB UGFI152C3
1” HUB UGFI152C3
The GFCI protected ACCEPTOR® is the solution to OSHA’s requirements for GFCI protection when using portable equipment in hazardous and wet loca-tions. For use with 125V, or125/250Vl 15 or 20 amp receptacles without GFCI protection, the Adapter Unit provides GFCI and circuit protection to connect-ed apparatus by simply being plugged into an existing receptacle.
The Hard-Wired Unit provides the same protection and is used directly as a GFCI protected device. Units are feed-through with one close-up plug.
L is t ed F i l e No . E91049k
Cer t i f i ed F i l e No . LR14667k
Typical Application with XHL Series Hand Lamp
7 3/86
6 1/8
7 7/8
Hard-Wired Unit
• Adapter Unit Class I, Div. 2, Groups B,C,D Class I, Zone 2, Groups IIB+H2, IIA Class II, Div. 1 & 2, Groups F,G Class III, Div. 1 & 2
• Hard-Wired Unit Class I, Div. 1 & 2, Groups B,C,D Class I, Zones 1 & 2, Groups IIB+ H2, IIA Class II, Div. 1 & 2, Groups F,G Class III, Div. 1 & 2
NEMA 3 ENCLOSURE TYPE(Adapter or Hard-Wired units)
Adapter Unit • No need to permanently alter existing
installations; Portable Unit can be temporarily hung using included strap near an existing receptacle wherever protection is required
• Factory Sealed Unit• Acceptor® plug and cord set included
with Adapter Unit. Cord is 36” Hard-Wired Unit • provides GFCI and circuit protection in
new installations, or as an upgrade or replacement for non-GFCI receptacles
• Factory Sealed, except Group BAdapter and Hard-Wired Unit• GFCI device also provides circuit
protection, for connected apparatus, against current overload and short circuits
• Acceptor® receptacles and plugs are intermateable with both Crouse-Hinds® Ark-Gard®2 and Appleton® U-Line® products
• Amber pilot light provides indication that the receptacle is energized.
• Units can be Padlocked OFF for main-tained safety
• Fully gasketed GFCI compartment prevents moisture from damaging electronic components
• Same high quality materials as the standard ACCEPTOR®
j Hard-Wired assemblies in Group B areas require sealing within 6” of enclosure.
k125VAC & 250 VAC devices are CCSAUS certified;125VAC devices are also UL Listed.
l 2P 250V units are for 2 “hot line” applications and include 2P 5mA GFI breakers. 2P Units are for 120/240V or 120/208Y Grounded Power Supply Systems ONLY. Do NOT use with Delta supply systems.
Ark-Gard® is a registered trademark of Crouse-Hinds® U-Line® is a registered trademark of Appleton Electric Company®.
Adapter Unit
UGFI GROUND FAULT PROTECTOR
5-20R
5-15R
6-20R
6-15R
20A
125V k
15A
125V k
1/2” HUB UGFI20C1
3/4” HUB UGFI20C2
1” HUB UGFI20C3
1/2” HUB UGFI15C1
3/4” HUB UGFI15C2
1” HUB UGFI15C3
5-20R
5-15R
6-20R
6-15R
20A
250V kl
15A
250Vkl
HARD WIRED (PERMANENTLY MOUNTED) GFCI RECEPTACLE
20A
125V k
15A
125V k
20A
250V kl
15A
250V kl
UGFI20AD
UGFI15AD
UGFI202AD
UGFI152AD
FEATURES-SPECIFICATIONS
C US
RETURN to
Index
FITTINGS
WWW.HUBBELL-KILLARK.COM R23
INSTALLATION ACCESSORIES
DURALOY® 8 SERIES
Iron conduit bodies. Use with threaded rigid conduit - steel or aluminum.
STANDARD LOCATION FITTINGS
DURALOY® 7 SERIES
Aluminum or Iron conduit bodies. Use with threaded rigid conduit - steel or aluminum.
MC AND CMCA SERIES
Metal clad cable connectors. Use with jacketed metal clad cable types.
Z SERIES
Used to secure & seal cords entering enclosures or raceways.
K SERIES
Liquidtight connectors. Use with flex-ible metallic and Type B liquidtight flex-ible nonmetallic conduit.
PCC/ECC/RACC SERIES
Conduit clamps. Use with threaded rigid conduit - steel or aluminum.
O SERIES
Aluminum conduit bodies. Use with threaded rigid conduit - steel or aluminum.
DURALOY® 5 SERIES
Malleable Iron conduit bodies. Use with threaded rigid conduit - steel or aluminum.
STANDARD LOCATION CONNECTORS
GEB/GE/GR SERIES
Aluminum and Iron outlet bodies. Use with threaded rigid condyit - steel or aluminum.
ENY/EY/EYS/EYD SERIES
Sealing Fittings and materials. Use with threaded rigid condyit - steel or aluminum.
PLUG/CUP/AN SERIES
Threaded Insert Plugs and rigid conduit nipples. Use to close up a tapped hole or hub.
UNF/UNY SERIES
Expansion Conduit Unions. Use to provide for slight expansion and contraction of conduit runs.
GU/UN SERIES
Aluminum and Iron unions. Use with threaded rigid conduit - steel or aluminum.
X/XALB SERIES
Aluminum conduit bodies. Use with threaded rigid condyit - steel or aluminum.
HAZARDOUS LOCATION FITTINGS HAZARDOUS LOCATION FITTINGS
FF/MF/MM/BL/GUFS/Y & EYMF SERIES
Aluminum and Iron elbows. Use to change direction in rigid or IMC conduit systems, or to join conduit at angles.
R/RE/ADUP SERIES
Reducing bushings and adapters. Use to reduce trade size of a tapped hole or hub.
CTCA, MCX & CMCXA SERIES
Metal clad cable connectors. Use with jacketed metal clad cable types in hazardous areas
EKJ SERIES
Stainless steel flexible coupling. Use where movement or vibration requires a flexible connection.
ECFUF/EKJUF/ECF/EKT SERIES
Bronze flexigle couplings with and without female steel unions. Use where movement or vibration requires a flexible connection.
HAZARDOUS LOCATION CONNECTORS
For Full Product Information go to
www.hubbell-killark.com
RETURN to
Index
MCVAR 04-14
PLUGS AND RECEPTACLES RANGE FROM KILLARKSee catalog data for complete ratings, certifications and series features
RACO® BELL® KILLARK® HAWKE® CHALMIT® WIEGMANN® VNATAGE® VICTOR® TAYMAC®
ELECTRICAL SYSTEMSA DIVISION OF HUBBELL INCORPORATED (DELEWARE)
3902 M. L. KING Dr. St. Louis, MO 63113Tel. (314) 531-0460 Fax. (314) 531-7164www.hubbell-killark.com
DISTRIBUTED BY:
SERIES HIGHLIGHTS SUITABILITY
NEW!150A MODEL
VP/VR/VPRNEMA 4X
VSQ/VSQ-FS/VBQHAZARDOUS LOCATIONSINTERLOCKED
KR SERIESHAZARDOUS LOCATIONSDELAYED ACTION
UGP/UGRHAZARDOUS LOCATIONSBLADE STYLE
NEW!QW
QUICK WIRING PLUG
UGRC/UGRPHAZARDOUS LOCATIONS
UGRSHAZARDOUS LOCATIONS
UGRF/UGFIHAZARDOUS LOCATIONS
Plug Connector
UGFI Adapter Unit Class I, Div. 2, Groups B,C,D Class I, Zone 2, Groups IIB+H2, IIA Class II, Div. 1 & 2, Groups F,G Class III, Div. 1 & 2
UGRF Class I, Div. 1 & 2, Groups C,DClass l, Zones 1 & 2, Groups llB,llAClass lI, Div. 1 & 2, Groups F,GClass IIINEMA 3, 7(C,D) 9(F,G)
Class I, Div. 2, Groups B,C,DClass I, Zone 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F,GClass IIINEMA 3, 4X
Class I, Div. 1 & 2, Groups B,C,DClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F,GClass IIINEMA 3, 4X*
Class I, Div. 1 & 2, Groups B,C,DClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F,GClass IIINEMA 3, 7 (B,C,D), 9 (F,G)
Class I, Div. 1 & 2, Groups B,C,DClass I, Zones I & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F & G Class lllNEMA 3, 4, 4X, 7 (B,C,D), 9 (F,G)
NEMA 3, 4, 4X, Receptacles
See product pages for plug ratings
• VSQ Hazardous or VWSQ (NEMA 4X only)• VSQ-FS is Factory Sealed (EXCLUSIVE)• VBQ Breaker Protected Interlocked Receptacle
Class I, Div. 1 & 2, GroupsC,DClass I, Zones I & 2, IIB, IIANEMA 7 (C,D)
• Heavy Duty Construction• Factory Sealed• Delayed Action Contacts
• 30, 60, 100, 150, 200 AMP Models• Allen/Slot Terminals• Interchangeability
• Interchangeable with other NEMA Bladed Explosion-proof Devices• Quick Wiring Plug for Easy Installation
• Used with Acceptor Plugs, Connectors & Panel Receptacles Extend Reach and Provide Local Access for Portable Equipment
• Square Receptacles Provide 'ROTATABLE' Configurations to Allow Cover Hinge to be in Convenient Location
• GFCI Devices Provide Circuit Protection for Con- nected Apparatus Against Overloads & Short Circuits• UGFI Available in Adapter & Hardwired Units
Flip Cap
NEW!
RETURN to