HARPER CHALICE GROUP LIMITED “PROTECTOR” PulseSecure ™ Fully monitored double pole High and...
-
Upload
ginger-andrews -
Category
Documents
-
view
219 -
download
2
Transcript of HARPER CHALICE GROUP LIMITED “PROTECTOR” PulseSecure ™ Fully monitored double pole High and...
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Fully monitored double poleHigh and Low voltage
Perimeter security system”
HARPER CHALICE GROUP LIMITED
“To maintain our position as a leading manufacturer and supplier of
External Security Systems & Complementary Products”.
Continuous Investment in
Research and Development
Market Research Listen to customers demands, requirements and wishes
Feed back:-Feed back:-
The ability to arm/disarm The ability to arm/disarm zones individually.zones individually.
The ability to monitor The ability to monitor systems with High Voltage systems with High Voltage deterrent switched on or off.deterrent switched on or off.
Detection of wire spreadingDetection of wire spreading Ease of Interface with other Ease of Interface with other
security systems.security systems. Graphic user interfaceGraphic user interface Remote test facilityRemote test facility
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Fully monitor HV/LV“Electrified Perimeter Security system”
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Features:-
High Security, fully monitored, double pole pulsed electrified system.
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Features:- All HT Pulsewire is zinc and aluminium coated for superior
corrosion resistance. Wire spacing - 100mm or 50mm High security Connections – corrosion resistant crimps All insulators designed with dual isolation rings to prevent system
loading due to contamination.
HARPER CHALICE GROUP LIMITED
“PROTECTOR” PulseSecure™
All insulators designed with dual isolation rings to prevent system loading due to contamination.
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Fully compliant with BS1722 part 17 – BS EN60335
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
System wiring:- High and low voltage monitoring of all system wiring.
(Fully monitors the fence detection system with High voltage deterrent on or off)
HV feed
HV return
Ground LV feed
Ground LV return
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored High Voltage and Low voltage
Electrified perimeter security System
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Zones:- Unlimited independent Zone configuration.
(Modular in single or dual zone configuration).
ControlRoom
Zone 1 Zone 2
2
Configuration using 2 zone HVLVI
Power Supply
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
Unlimited multi zone configuration
Zone 3 Zone 4Zone 1 Zone 2 Zone 5 Zone 6 Zone 7
2 2 2
Communication bus to next zones and control systemLow Voltage Power
Supply
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Wiring:- Simplified connection wiring via Belden wire data cable or fibre
Low voltage AC power supplies to HVLV Interfaces for maximum safety and installation cost savings.
Multiple zone configuration
“PROTECTOR” 3GS
Control
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Zones:- Addressable zones Independent arming/disarming of each zone
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Zones:- Addressable remote testing of each zone.
(Fully functional remote testing of each zone).
Multiple zone configuration
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
= High voltage deterrent on
= High voltage deterrent off
All zones are fully monitored and can be independently armed/disarmed with high voltage deterrent
1
= Zone Isolated
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
“PROTECTOR” 3GS
Control
Multiple zone configuration
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
= High voltage deterrent on
= High voltage deterrent off
All zones are fully monitored and can be independently armed/disarmed with high voltage deterrent
1
= Zone Isolated
PROTECTOR” 3GS
Control
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
Multiple zone configuration
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
= High voltage deterrent on
= High voltage deterrent off
All zones are fully monitored and can be independently armed/disarmed with high voltage deterrent
1
= Zone Isolated
PROTECTOR” 3GS
Control
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
Multiple zone configuration
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
All zones are fully monitored and can be independently armed/disarmed with high voltage deterrent
1
= High voltage deterrent on
= High voltage deterrent off
= Zone Isolated
PROTECTOR” 3GS
Control
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
Multiple zone configuration
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
All zones are fully monitored and can be automatically armedwith high voltage deterrent
1
= High voltage deterrent on
= High voltage deterrent off
= Zone Isolated
PROTECTOR” 3GS
Control
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
Multiple zone configuration
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
All zones are fully monitored and can be independently armed/disarmed with high voltage deterrent
1
= High voltage deterrent on
= High voltage deterrent off
= Zone Isolated
PROTECTOR” 3GS
Control
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
1
Multiple zone configuration – All zone HV deterrent ON
2 3 4 5 6
7
8
12 11 10 9
16
15
14 13
High voltage deterrent on High voltage deterrent offZone Isolated
ProtectedPremises
Protectedexternal
area
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
1
Multiple zone configuration – all zone HV deterrent off
2 3 4 5 6
7
8
12 11 10 9
16
15
14 13
High voltage deterrent on High voltage deterrent offZone Isolated
ProtectedPremises
Protectedexternal
area
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
1
Gate zone with HV off during day time
2 3 4 5 6
7
8
12 11 10 9
16
15
14 13
High voltage deterrent on High voltage deterrent offZone Isolated
ProtectedPremises
Protectedexternal
area
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
1
Gate zone and adjacent zones with HV off during day time
2 3 4 5 6
7
8
12 11 10 9
16
15
14 13
High voltage deterrent on High voltage deterrent offZone Isolated
ProtectedPremises
Protectedexternal
area
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
1
Multiple zone configuration – all zone HV deterrent off Zone - 10 detects tamper alarm
2 3 4 5 6
7
8
12 11 10 9
16
15
14 13
High voltage deterrent on High voltage deterrent offAlarmed Zone
ProtectedPremises
Protectedexternal
area
PulseSecure™ “PROTECTOR
PS710 seriesFully Monitored Control System
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Independent zone alarm outputs for High Voltage and Low Voltage
Monitored alarms.
Programmable Normally open or normally closed alarm relays for interfacing with CCTV or other security/monitoring systems.
Outputs
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Features:- Strong, lockable GRP IP65 external housings
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Features:- Compatible with 3GS SEAP Class 4 system.
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Features:- Keypad operated with optional Graphic display and control via PC
HARPER CHALICE GROUP LIMITED
“PROTECTOR”
PulseSecure™
Communications: - Communication system fully net workable over IP or RS485
RS232 output for interfacing directly with most common CCTV protocols.
Full compatibility and functionality of 3GS Integrated security solution.