Hansen House (Passive house Miguel Salgado)

33
PASSIVE HOUSE Group: 19 Miguel Salgado Pedro Rico Adam Marko

description

"Hansen House" is a Passive House design for a single falmily house in Denmark. This house follows the Passive House Standard guidelines and also fullfils the criteria taking into consideration the needs of the family.

Transcript of Hansen House (Passive house Miguel Salgado)

Page 1: Hansen House (Passive house Miguel Salgado)

PASSIVE HOUSE

Group: 19

Miguel SalgadoPedro RicoAdam Marko

Page 2: Hansen House (Passive house Miguel Salgado)

1. INTRODUCTION LOCATION

Galgehøj, 8700 Horsens Plot 33

Page 3: Hansen House (Passive house Miguel Salgado)

2. DESIGN A/V FACTOR

NUMBER OF FLOORS 2

A (GROSS FLOOR AREA) 154m2

A (BUILDING ENVELOPE) 420m2

V (GROSS ENVELOPE) 539m3

A/V 0,78m2/m3

Page 4: Hansen House (Passive house Miguel Salgado)

2. DESIGN AREAS

Ground floor

Page 5: Hansen House (Passive house Miguel Salgado)

2. DESIGN AREAS

1st floor

Page 6: Hansen House (Passive house Miguel Salgado)

2. DESIGN DIMENSIONS

Ground floor

Page 7: Hansen House (Passive house Miguel Salgado)

2. DESIGN DIMENSIONS

1st floor

Page 8: Hansen House (Passive house Miguel Salgado)

2. DESIGN U-VALUES

Assembly No. Building assembly description Interior insulation?

1 External Wall

Heat transfer resistance [m²K/W] interior Rsi : 0,13exterior Rse : 0,04

Area section 1l [W/(mK)] Area section 2 (optional)

l [W/(mK)] Area section 3 (optional)l [W/(mK)] Thickness [mm]

1. Brick 0,600 108

2. Insulation 0,032 350

3. Finish layer 0,250 10

4.

5.

6.

7.

8.Percentage of Sec. 2 Percentage of Sec. 3 Total

46,8 cm

U-Value: 0,088 W/(m²K)

Page 9: Hansen House (Passive house Miguel Salgado)

2. DESIGN U-VALUES

Assembly No. Building assembly description Interior insulation?

2 Roof

Heat transfer resistance [m²K/W] interior Rsi : 0,26

exterior Rse : 0,04

Area section 1 l [W/(mK)] Area section 2 (optional) l [W/(mK)] Area section 3 (optional) l [W/(mK)] Thickness [mm]

1. Tile 1,000 20

2. Mortar 0,100 100

3. Insulation 0,034 400

4. Mortar 0,100 50

5. Concrete 1,600 200

6.

7.

8.Percentage of Sec. 2 Percentage of Sec. 3 Total

77,0 cm

U-Value: 0,073 W/(m²K)

Page 10: Hansen House (Passive house Miguel Salgado)

2. DESIGN U-VALUES

Assembly No. Building assembly description Interior insulation?

3 Ground Floor supporter floor

Heat transfer resistance [m²K/W] interior Rsi : 0,17

exterior Rse: 0,00

Area section 1l [W/(mK)] Area section 2 (optional)

l [W/(mK)] Area section 3 (optional)l [W/(mK)] Thickness [mm]

1. Parquet 0,200 20

2. concrete 1,600 100

3. Hard insulation 0,037 350

4. Light clincker 0,085 250

5. Light clincker 0,102 75

6.

7.

8.Percentage of Sec. 2 Percentage of Sec. 3 Total

79,5 cm

U-Value: 0,074 W/(m²K)

Page 11: Hansen House (Passive house Miguel Salgado)

2. DESIGN ORIENTATION AND WINDOWS

WINDOWS

NORTH 9,5%

EAST 22,1%

SOUTH 44,9%

WEST 23,5%

Page 12: Hansen House (Passive house Miguel Salgado)

2. DESIGN ORIENTATION AND WINDOWS

Glazing.

Frame

Page 13: Hansen House (Passive house Miguel Salgado)

2. DESIGN SHADINGS

Page 14: Hansen House (Passive house Miguel Salgado)

2. DESIGN ELEVATIONS (SOUTH)

Page 15: Hansen House (Passive house Miguel Salgado)

2. DESIGN ELEVATIONS (EAST)

Page 16: Hansen House (Passive house Miguel Salgado)

2. DESIGN ELEVATIONS (WEST)

Page 17: Hansen House (Passive house Miguel Salgado)

2. DESIGN ELEVATIONS (NORTH)

Page 18: Hansen House (Passive house Miguel Salgado)

2. DESIGN SECTIONS (A-A’)

A’

A

B’B

Page 19: Hansen House (Passive house Miguel Salgado)

2. DESIGN SECTIONS (B-B’)

A’

A

B’B

Page 20: Hansen House (Passive house Miguel Salgado)

2. DESIGN DETAILS

Wall-Window

Page 21: Hansen House (Passive house Miguel Salgado)

2. DESIGN DETAILS

Roof-Wall

Air thingt layer

Page 22: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION

Passive House Standard

Supply air:30m3/h/person * 4 person = 120m3/h

Extract air:

1 Kitchen: 60 m3/h3 Bathrooms: 40 m3/h * 3 = 120 m3/h2 Storage room: 40 m3/h

Total= 220 m3/h

Minimun ari change of 0,3/h:

0,3/h*144 m2*2,5= 108 m3/h

Page 23: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION

INNOAIR 300 DC (max. 300 m³/h bei 100 Pa.)

Page 24: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION (SUPPLY)

Room No qbasic

(l/s)qbasic

(m3/s)Ʃq dimensioning

(m3/s)Type (M, B, C)

Velocity(m/s)

Duct dimension (calculated) (m)

Final duct dimension (mm)

Living room

12,5 0,0125 0,0125 C 2,5 75 75

Dinnigroom

12,5 0,0125 0,0125 C 2,5 75 75

Branch1

25 0,0250 0,0250 B 3,5 90 90

Room 1 11,2 0,0112 0,0112 C 2,5 75 75

Room2

11,2 0,0112 0,0112 C 2,5 75 75

Branch2

22,4 0,024 0,024 B 3,5 100 100

Room3

17 0,017 0,017 C 2,5 100 100

Branch3

39,4 0,0394 0,0394 B 3,5 125 125

Main 64,4 0,0644 0,0644 M 4 150 150

Page 25: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION (EXTRACTION)

Room No qbasic

(l/s)qbasic

(m3/s)Ʃq dimensioning

(m3/s)Type (M, B, C)

Velocity(m/s)

Duct dimension (calculated) (m)

Final duct dimension (mm)

Kitchen 20 0,020 0,020 C 2,5 90 90

Bathroom1

15 0,015 0,015 C 2,5 75 75

Branch1

35 0,0350 0,0350 B 3,5 110 110

Storage1

10 0,01 0,01 C 2,5 75 75

Brach2

45 0,045 0,045 B 3,5 125 125

Bathroom2

15 0,015 0,015 C 2,5 75 75

Storage2

10 0,01 0,01 C 2,5 75 75

Bathroom3

15 0,015 0,015 C 2,5 75 75

Brach3

40 0,04 0,04 B 3,5 125 125

Main 85 0,085 0,085 M 4 175 175

Page 26: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION (PLANS)

Ground floor

Suppy

Extract

Page 27: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION (PLANS)

1st floor

Suppy

Extract

Page 28: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS VENTILATION

Suppy

Extract

Page 29: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS DOMESTIC HOT WATER

Ground floor

Page 30: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS DOMESTIC HOT WATER

1st floor

Page 31: Hansen House (Passive house Miguel Salgado)

3. INSTALATIONS DOMESTIC HOT WATER

Page 32: Hansen House (Passive house Miguel Salgado)

4. CONCLUSIONS VERIFICATION

Page 33: Hansen House (Passive house Miguel Salgado)

THATS ALL!!THANKS!!

Group: 19