H600/H1000 Series - Winkler-Stiefel

32
H600/H1000 Series High Pressure In-Line Filters3 Max 1000 l/min - 414 bar Global Filtration Technology

Transcript of H600/H1000 Series - Winkler-Stiefel

Page 1: H600/H1000 Series - Winkler-Stiefel

H600/H1000 SeriesHigh Pressure In-Line Filters3

Max 1000 l/min - 414 bar

Global Filtration Technology

03 HIGH PRESSURE FILTERS 28/6/02 9:41 am Page 97

Page 2: H600/H1000 Series - Winkler-Stiefel

High Pressure In-Line FiltersH600/H1000 Series

TYPICAL APPLICATIONS

Drilling Rigs

Power Packs

Oil/Gas Industry

Flight Simulators

Test Rigs

The Parker Filtration Model H600/H1000 High Pressure In-Line Filters.

The H600/H1000 Series is designed to meet the growing demand for high-pressure

filters with a flow rate capacity of up to 1000 l/min at 414 bar working pressure. A

wide range of elements is available to offer system-matched protection of the hydraulic

system. For systems where reverse flow can be expected, an optional integrated reverse

flow valve avoids back wash of contamination. The elements and filter media used

include high-quality materials such as HPFE glass fibre and stainless steel mesh as well

as high strength mesh cleanable elements and high strength fibre disposable elements.

When changing the element, only the end cap of the bowl has to be removed. The filter

is ideal for applications where space is at a premium.

TYPICAL APPLICATIONS

98

03 HIGH PRESSURE FILTERS 28/6/02 9:41 am Page 98

Page 3: H600/H1000 Series - Winkler-Stiefel

High Pressure In-Line FiltersH600/H1000 Series

SPECIFICATION

Assembly:In-Line filter, filter housing pressure pulse fatigue test:3,000,000 cycles 0-276 bar

Operating Pressure:Max. 414 bar

Connections:Threads G11/2, G2 (ISO228), SAE 24, SAE 32, Flanges (rating6000psi) SAE 11/2”, SAE 2”

Seal Material:Nitrile, Neoprene, Fluoroelastomer

Operating Temperature Range:-40°C to 100°C

Degree of Filtration:Determined by multipass test according to ISO 16889

Filtration Media:HPFE glass fibre GDH multi layer glass fibre. (See Table A).

Flow Fatigue Characteristics:Filter media is supported so that the optimal fatigue life is achieved

Element Collapse Rating:20 bar (ISO 2941), 210 bar for high strength element

Bypass Setting:7.0 bar

Differential Pressure Indicator:5.0 barDifferential indicator visualDifferential indicator electrical

Options:Reverse flow valve

Filter Housing:Head S.G. Iron casting, Bowl extruded steel

Filter Element:Element with steel end capsHigh strength element on request only

1 Filter head2 Filter element3 Bowl seal

3A Bowl back-up ring4 Housing5 Cover6 Indicator seal7 Bypass set8 Visual indicator9 Electrical indicator10 Bypass seal11 Reverse flow set12 Adaptor13 Adaptor/reverse flow seal14 Cover seal15 Drain plug

TYPE H MODEL 1000

1

2

3/3A

3/3A

4

5

6

7

8

9

1013

11

12

14

15

Ø169

Ø125

Ø145

Ø145

107.

510

588

35

235

15

SAE 646 A/F

MIN

IMU

M E

LEM

EN

TC

LEA

RA

NC

E

330/

580

L1=

563

L2=

813

10055A/F

99

03 HIGH PRESSURE FILTERS 28/6/02 9:41 am Page 99

Page 4: H600/H1000 Series - Winkler-Stiefel

High Pressure In-Line FiltersH600/H1000 Series

Flow (l/min)

∆p (

bar

)

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

0 100 200 300 400 500 600

RFV

Flow (US GPM)

0 79 106 132 1595326

∆p (

psi

d)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

23.2

Adapter

Flow (l/min)

∆p (

bar

)

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

0 100 200 300 400 500 600

GDH3

GDH6

GDH10GDH20

Flow (US GPM)

0 79 106 132 1595326

∆p (

psi

d)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

23.2

600 Housing (G11/2”, SAE 24, SAE 11/2”)

600 ElementsFlow (l/min)

∆p (

bar

)

0

0.5

1

1.5

2

2.5

0 200 400 600 800 1000

Adapter

RFV

∆p (

psi

d)

0

7.3

14.5

21.8

29.0

36.3

Flow (US GPM)

0 106 159 211 26453

Flow (l/min)

∆p (

bar

)

0

0.5

1

1.5

2

2.5

3

0 200 400 600 800 1000

GDH3

GDH6

GDH10

GDH20

∆p (

psi

d)

0

7.3

14.5

21.8

36.3

43.5

29.0

Flow (US GPM)

0 106 159 211 26453

1000 Housing (G2”, SAE 32, SAE 2”)

1000 Elements

PRESSURE DROP CURVES

ADDITIONAL INFORMATION

CIRCUIT SYMBOL

Filter withReverse Flow Valve

Normal Flow Condition

Reverse Flow Condition

VALVE HOUSING

VALVE HOUSING

SLEEVE

CENTRAL STEM

100

03 HIGH PRESSURE FILTERS 28/6/02 9:41 am Page 100

Page 5: H600/H1000 Series - Winkler-Stiefel

High Pressure In-Line FiltersH600/H1000 Series

Ordering Code1074A2HN70-FZ12101074A2HN70-FZ12201074A2HN70-FZ12301074A2HN70-TZ22101074A2HN70-TZ22201074A2HN70-TZ2230

Ordering Code Flow (l/min)600600600100010001000

Flow (l/min) Micron RatingGDH 06GDH 10GDH 20GDH 06GDH 10GDH 20

Media Rating Ports11/2” SAE Flange11/2” SAE Flange11/2” SAE Flange2” SAE Flange2” SAE Flange2” SAE Flange

Ports IndicatorVisualVisualVisualVisualVisualVisual

Indicator Replacement Elements1070Z121A1070Z122A1070Z123A1070Z221A1070Z222A1070Z223A

Replacement Elements

PREFERRED PRODUCTS TABLE

ORDERING EXAMPLE

1 2 Std 8 9 10 4

Element

Filter Assembly

1 2 3 4 5 5A 6 7 8 9 10 11

10 7 4 A 2H N 70 – B Z 1 23 0

10 7 0 Z 1 23 A

Element TypeHigh strength fibre (210 bar)HPFE glass fibre GDH

CODE57

CODE10

HousingModel 1000

Element TypeFilter Type

Table 1

Table 10

Table 2

VarietyStandard flowReverse flow valve (RFV)

CODE42

Flow Direction

Table 3

OptionsStandard

CODE0

Options

Table 11

High strength fibre ßx≥ 75

GDH glass fibre ßx≥ 75

Filtration fineness

3µm

FF

20

6µm

21

10µm

22

15µm

10

20µm

23

Degree of Filtration

Seal MaterialNitrile (Buna) (NBR)Neoprene (CR)Fluoroelastomer (FPM)

CODEABH

Seal Type

Table 4

Bypass differential pressure settingNo bypassBypass setting 7.0 bar

CODE0070

Bypass Valve

Table 6

PortsISO 228- G11/2 (BSP)ISO 228- G2 (BSP)SAE 24SAE 3211/2” SAE Flange 414 bar2” SAE Flange 414 bar

CODEBESHFT

Filter Connection

Table 7

Element length600 l/min1000 l/min

CODE12

Element Length

Table 9

Element typesAll fluids exc. phosphate esters,water glycols and ammoniacontaining oils.

CODEAll

ratingsZ

Element Information

Table 8

Table 5ATable 5

Bypass typeNo bypass portBypass valveBypass valveNo bypass valve

Bypass valve

No bypass valve

Indicator code

No indicator

Standard visual indicator

Electrical Din 43650 28V=/ 250 V ~ No lampsElec./Visual indicator 250 V ~ Green lamps N.C.Elec./Visual indicator 250 V ~ Red lamps N.O.Elec./Visual indicator 110 V ~ Green lamps N.C.Elec./Visual indicator 110 V ~ Red lamps N.O.Elec./Visual indicator 28 V = Green lamps N.C.Elec./Visual indicator 28 V = Red lamps N.O.

Setting

5.0 bar

5.0 bar

0H1H2H4H

3H

5H

N

N

THKCMER

Bypass Indicators

Note: Filter assemblies ordered from the Part Number Matrix below are on extended lead times.Where possible, please make your selection from the table above.

Average filtration Beta Ratio (ISO 16889) / particle size µm(c)

2 10 75 100 200 1000

N/A 3.0 4.1 4.4 4.9 6.7

N/A 4.0 6.7 7.0 7.9 10.0

3.1 6.2 9.9 10.4 11.6 14.6

6.7 12.6 17.8 18.5 20.0 22.6

CODE

GDL3/GDH3

GDL6/GDH6

GDL10/GDH10

GDL20/GDH20

Degree of FiltrationTable A

101

03 HIGH PRESSURE FILTERS 28/6/02 9:41 am Page 101

Page 6: H600/H1000 Series - Winkler-Stiefel

18/28/38P SeriesHigh Pressure Filters

Max 520 l/min - 414 bar

Global Filtration Technology

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 103

Page 7: H600/H1000 Series - Winkler-Stiefel

High Pressure Filters18/28/38P Series

TYPICAL APPLICATIONS

Injection Moulding

Die Casting

Servo Controls

Machine Tools

Mobile Equipment

Parker Filtration engineered the 18/28/38P series of high pressure filters to

satisfy demanding applications in the mobile and industrial markets

throughout the world. With metric mounting and optional ISO 6149 ports,

this new series is truly a global design.

Installed downstream of the pump, this new series with their wide range of

high capacity Microglass III elements, offer excellent protection to system

components.

Standard filters come complete with industry proven spool type bypass

valve. For more critical applications such as servo or proportional controls, a

no bypass high strength element combination ensures maximum protection.

The modular low hysteresis differential pressure indicator fitted to this series

is unrivaled in its performance. Tests prove its accuracy and foolproof design

to be a major advance in indicator technology.

TYPICAL APPLICATIONS

104

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 104

Page 8: H600/H1000 Series - Winkler-Stiefel

High Pressure Filters18/28/38P Series

SPECIFICATION

Maximum Allowable Operating Pressure:414 bar (6000 psi). Factor safety 3:1Operating Temperature Range:-40° to 120°C (-30°F to +250°F)Materials of Construction:SG iron head, steel bowlPorts:Inlet and outlet ports are threaded internally or flange facedPort Style Model

18P 28P 38PBSPF(G) 3/4” 1” 11/4”, 11/2”SAE 12 16 20, 24ISO 6149 M27 M33 M42, M48SAE 6000-config 3/4” 1” 11/4”Metric 6000-M config* 3/4” 1” 11/4”*6000-M is SAE style with appropriate metric fixing threadsBypass Valve & Indicator Settings:Table below gives bypass valve and corresponding indicatorsettingBypass Indicator3.5 bar 2.5 bar7.0 bar 5.0 bar

Weights (kg):Model Length 1 Length 218P 4.2 5.728P 6.7 9.238P 15.8 20.3Fluid Compatibility:Suitable for use with mineral oils, most water glycols and other waterbased fluids. For other fluids, please consult Filter Division EuropeSeals:Head to bowl, diametral with anti-extrusion ring.Materials - Nitrile or Fluoroelastomer*Element Condition Indicators: (Differential Pressure Type)Cartridge type visual, with auto reset. Cartridge type electrical,with auto reset and socket to DIN43650, protection class IP65Electrical Ratings:Power - 5 VA max, Current - 0.25 A max (resistive), Voltage -28 VDC max, 28 VAC (50-60Hz) max, Contacts - normallyopen and normally closed, wired to DIN plug pin codeFilter Elements:Microglass III supported with epoxy coated steel mesh. (See Table 4).Element Collapse Rating:Standard; 20 bar differential minimum. High collapse; 210 bardifferential minimum*Fluoroelastomers are available under various registered trademarks, includingViton (a registered trademark of DuPont) and Fluorel (a registered trademark of 3M)

Model

198(7.79)293

(11.53)228

(8.97)337

(13.26)329

(12.95)448

(17.64)

32(1.26)

40(1.57)

44(1.73)

26(1.02)

29(1.14)

35(1.38)

75(2.95)

93(3.66)

128(5.04)

24(0.94)

40(1.14)

36(1.42)

100(3.94)

98(3.86)

120(4.72)

160(6.30)

40(1.57)

55(2.16)

50(1.97)

20(0.79)

27.5(1.07)

25(0.98)

80(3.15)

90(3.54)

120(4.72)

40(1.57)

45(1.77)

60(2.36)

55(2.16)

62(2.44)

81(3.19)

110(4.33)

124(4.88)

162(6.38)

M8 x 1.25x12

(0.47)deep

M10 x 1.5x11

(0.43)deep

M10 x 1.5x12

(0.47)deep

18P-1

18P-2

28P-1

28P-2

38P-1

38P-2

A B C D E F G H J K L M N P(A/ F )

18P 28P 38P

B C

Torque15-20 ft/lbs.(22-27Nm)

Single Length(A)

Double Length(B)

Hex. 23.324.0 A/FBowl Removal

F

CB

Single Length(A)

Double Length(B)

Bowl RemovalF

Hex. 23.324.0 A/F

Torque25-30 ft/lbs.(34-40 Nm)

B C

Single Length(A)

Double Length(B)

Bowl RemovalF

Torque60-70 ft/lbs.(81-95 Nm)

Hex. 35.3836.0 A/F

K

GH

J

LN

M

15°

4 Mounting Holes (P)

G

H

J

K

LM

N

4 Mounting Holes (P)

15°R30 R3

5

G

JH

NM

15°

LK

R38

4 Mounting Holes (P)

mm(inches)

D DD

105

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 105

Page 9: H600/H1000 Series - Winkler-Stiefel

Note: For full indicator specifications see Section 6.

Element Condition Indicators:

VISUAL AUTO RESETCODE M2

48 VAC ELECTRICAL VISUAL INDICATORCODE E2

FLANGE FACE DETAILS

High Pressure Filters18/28/38P Series

INDICATOR DETAILS

B

N/A

Pin 1 – CommonPin 2 – Normally ClosedPin 3 – Normally Open

N/A

2.90 (73.7)

1.44 (36.6)

1.44 (36.6)

Option Description Connection/Voltage Wiring “A” “B”

M2

E2

Visual Auto Reset

Electrical – Visual

N/A

Din 43650 3 Pole + Earth5A@48 VAC, 3A@28VDC

A

B

1

3

2

Modelmm (inches)

11.9

(0.47)

14

(0.55)

15.7

(0.62)

23.8

(0.94)

27.8

(1.09)

31.7

(1.25)

25.4

(1.00)

28.0

(1.10)

33.0

(1.30)

50.8

(2.0)

57.1

(2.25)

66.7

(2.62)

M10 x 1.5-6H x 18 Deep

M12 x 1.75-6H x 20 Deep

M14 x 2-6H x 20 Deep

3/8-16 UNC-2B x 18 Deep

7/16-14 UNC-2B x 20 Deep

1/2-13 UNC-2B x 20 Deep

19.0

(0.75)

25.4

(1.0)

31.8

(1.25)

18P

28P

38P

A B C D E F G

C

D

AB

Ø G

Thread E metricF SAE

106

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 106

Page 10: H600/H1000 Series - Winkler-Stiefel

High Pressure Filters18/28/38P Series

18P-1 Empty Housing and High Collapse

28P-1 Element Only

18P-1 Element Only

18P-2 High Collapse Elements Only

28P-2 Element Only

43.5

29.0

0

0 5 11 21

Flow (US GPM)

Flow (l/min)20 40 8060

0.0

∆p (

bar

)

20QH1.0

2.0

3.0

0

0.5

1.5

2.5

16

14.5

∆p (

psi

d)

10QH

05QH

02QH

Empty Housing

100

26

43.5

29.0

0

0 5 11 21

Flow (US GPM)

Flow (l/min)20 40 8060

0.0

∆p (

bar

)

20QH

1.0

2.0

3.0

0

0.5

1.5

2.5

16

14.5

∆p (

psi

d)

10QH

05QH

02QH

100

26

43.5

29.0

0

0 13 26 66

Flow (US GPM)

Flow (l/min)50 100 250200

0.0

∆p (

bar

)

20Q

1.0

2.0

3.0

0

0.5

1.5

2.5

53

14.5

∆p (

psi

d)10Q

05Q02Q

150 300

39 79

43.5

29.0

0

0 5 11 21

Flow (US GPM)

Flow (l/min)20 40 8060

0.0

∆p (

bar

)

20Q1.0

2.0

3.0

0

0.5

1.5

2.5

16

14.5

∆p (

psi

d)

10Q

05Q

02Q

100

26

18P-2 Element Only

43.5

29.0

0

0 5 11 21

Flow (US GPM)

Flow (l/min)20 40 8060

0.0

∆p (

bar

)

20Q

1.0

2.0

3.0

0

0.5

1.5

2.5

16

14.5

∆p (

psi

d)

10Q

05Q

02Q

100

26

43.5

29.0

0

0 13 26 66

Flow (US GPM)

Flow (l/min)50 100 250200

0.0

∆p (

bar

)

20Q1.0

2.0

3.0

0

0.5

1.5

2.5

53

14.5∆p

(p

sid

)10Q

05Q

02Q

150 300

39 79

28P-1 Empty Housing and High Collapse 28P-2 High Collapse Elements Only

43.5

29.0

0

0 13 26 66

Flow (US GPM)

Flow (l/min)50 100 250200

0.0

∆p (

bar

)

20QH

1.0

2.0

3.0

0

0.5

1.5

2.5

53

14.5

∆p (

psi

d)

10QH05QH

02QH

150 300

39 79

Empty Housing

43.5

29.0

0

0 13 26 66

Flow (US GPM)

Flow (l/min)50 100 250200

0.0

∆p (

bar

) 20QH

1.0

2.0

3.0

0

0.5

1.5

2.5

53

14.5

∆p (

psi

d)

10QH05QH02QH

150 300

39 79

PRESSURE DROP CURVESIf the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows :-

p = ( p30 x viscosity of medium used) / 30 cSt

107

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 107

Page 11: H600/H1000 Series - Winkler-Stiefel

High Pressure Filters18/28/38P Series

38P-1 Empty Housing and High Collapse

38P-1 Element Only

38P-2 High Collapse Elements Only

43.5

29.0

0

0 26 53 132

Flow (US GPM)

Flow (l/min)100 200 500400

0.0

∆p (

bar

)

20QH

1.0

2.0

3.0

0

0.5

1.5

2.5

106

14.5

∆p (

psi

d)

10QH05QH

02QH

300

79

Empty Housing

159

600

43.5

29.0

0

0 26 53 132

Flow (US GPM)

Flow (l/min)100 200 500400

0.0

∆p (

bar

) 20QH

1.0

2.0

3.0

0

0.5

1.5

2.5

106

14.5

∆p (

psi

d)

10QH

05QH

02QH

300

79 159

600

43.5

29.0

0

0 26 53 132

Flow (US GPM)

Flow (l/min)100 200 500400

0.0

∆p (

bar

)

20Q1.0

2.0

3.0

0

0.5

1.5

2.5

106

14.5

∆p (

psi

d)

10Q

05Q02Q

300

79 159

600

38P-2 Element Only

43.5

29.0

0

0 26 53 132

Flow (US GPM)

Flow (l/min)100 200 500400

0.0

∆p (

bar

)

20Q

1.0

2.0

3.0

0

0.5

1.5

2.5

106

14.5

∆p (

psi

d)

10Q

05Q

02Q

300

79 159

600

02Q05Q10Q20Q

02QH05QH10QH20QH

74

78

67

60

57

61

56

54

111

105

101

100

87

88

80

78

28

28

24

24

24

27

23

22

48

50

48

48

38

38

38

37

7.4

9.4

8.0

8.6

6.3

8.8

7.2

7.2

22.7

23.5

17.2

17.7

17.8

19.6

16.1

12.6

Media 38P-1 38P-2 28P-1 28P-2 18P-1 18P-2Code (98 psid) (98 psid) (98 psid) (98 psid) (98 psid) (98 psid)

CAPACITY IN GRAMS

108

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 108

Page 12: H600/H1000 Series - Winkler-Stiefel

High Pressure Filters18/28/38P Series

Element ServiceA. Stop the system s power unit.

B. Relieve any system pressure in the filter line.

C. Drain the filter bowl if drain port option is provided.

D. Rotate the bowl clockwise (left) and remove.

E. Remove element by pulling downward with a slight twisting motion

and discard.

F. Check bowl o-ring and anti-extrusion ring for damage and replace

if necessary.

G. Lubricate element o-ring with system fluid and locate element in

filter head.

H. Install bowl by rotating counter-clockwise (right) and tighten to

specified torque.

18P — 15-20ft. lbs (22-27 Nm)

28P — 25-30ft. lbs (34-40 Nm)

38P — 60-70ft. lbs (81-95 Nm)

I. Confirm there are no leaks after powering the system.

Head AssemblyElementBowlSingle lengthDouble lengthIndicatorsM2 – Visual autoresetE2 – Elecrical/Visualw/DIN connectionBowl SealBowl Anti-extrusion Ring*Seal Kit – (Nitrile)*Seal Kit – (Fluoroelastomer)

123

45

67

Index Description

Parts List

6

7

3

2

1

5

4

109

* Includes bowl o-ring, bowl anti-extrusion washerand indicator o-rings

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 109

Page 13: H600/H1000 Series - Winkler-Stiefel

Part Number18P-1-02Q-M2-98-B2B2-118P-1-05Q-M2-98-B2B2-118P-1-10Q-M2-98-B2B2-118P-1-20Q-M2-98-B2B2-118P-2-02Q-M2-98-B2B2-118P-2-05Q-M2-98-B2B2-118P-2-10Q-M2-98-B2B2-118P-2-20Q-M2-98-B2B2-128P-1-02Q-M2-98-C2C2-128P-1-05Q-M2-98-C2C2-128P-1-10Q-M2-98-C2C2-128P-1-20Q-M2-98-C2C2-128P-2-02Q-M2-98-C2C2-128P-2-05Q-M2-98-C2C2-128P-2-10Q-M2-98-C2C2-128P-2-20Q-M2-98-C2C2-138P-1-02Q-M2-98-D2D2-138P-1-05Q-M2-98-D2D2-138P-1-10Q-M2-98-D2D2-138P-1-20Q-M2-98-D2D2-138P-2-10Q-M2-98-D2D2-1

Part Number18P-1-02Q-E2-98-B2B2-118P-1-05Q-E2-98-B2B2-118P-1-10Q-E2-98-B2B2-118P-1-20Q-E2-98-B2B2-118P-2-02Q-E2-98-B2B2-118P-2-05Q-E2-98-B2B2-118P-2-10Q-E2-98-B2B2-118P-2-20Q-E2-98-B2B2-128P-1-02Q-E2-98-C2C2-128P-1-05Q-E2-98-C2C2-128P-1-10Q-E2-98-C2C2-128P-1-20Q-E2-98-C2C2-128P-2-02Q-E2-98-C2C2-128P-2-05Q-E2-98-C2C2-128P-2-10Q-E2-98-C2C2-128P-2-20Q-E2-98-C2C2-138P-1-02Q-E2-98-D2D2-138P-1-05Q-E2-98-D2D2-138P-1-10Q-E2-98-D2D2-138P-1-20Q-E2-98-D2D2-138P-2-10Q-E2-98-D2D2-1

Flow (l/min)356090

100609011013080

100150200120160200240130250360450500

Media Rating02Q05Q10Q20Q02Q05Q10Q20Q02Q05Q10Q20Q02Q05Q10Q20Q02Q05Q10Q20Q10Q

PortsG3/4

G3/4

G3/4

G3/4

G3/4

G3/4

G3/4

G3/4

G1G1G1G1G1G1G1G1

G11/4

G11/4

G11/4

G11/4

G11/4

Replacement ElementsG04242G04243G04244G04245G04250G04251G04252G04253G04258G04259G04260G04261G04266G04267G04268G04269G04274G04275G04276G04277G04284

PREFERRED PRODUCTS TABLE

The following filters are supplied with 7.0 bar bypass and Nitrile seals.

High Pressure Filters18/28/38P Series

PART NUMBER MATRIXTable 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9

F3 28P 1 10Q M2 98 C2C2 1 –

Note: Indicator Differential Pressure Settings2.5 bar with 3.5 bar bypass5.0 bar with 7.0 bar bypass5.0 bar with no bypass

MODEL18P

28P

38P

SYMBOLB2B2M4M4B3B3Y3Y3

Y9Y9

C2C2N4N4C3C3Y3Y3

Y9Y9

D2D2E2E2O4O4P4P4D3D3E3E3Y3Y3

Y9Y9

DescriptionG3/4” Thread12, SAE ThreadM27, ISO 61493/4” 6000-M Flange Face3/4” 6000-M Config.Flange FaceG116 SAE ThreadM33, ISO 61491” 6000-M Flange Face1” 6000-M Config.Flange FaceG11/4” ThreadG11/2” Thread20 SAE Thread24 SAE ThreadM42, ISO 6149M48, ISO 614911/4” 6000-M Flange Face11/4” 6000-M Config.Flange Face

SYMBOL

N

M2

V6

E2

TW6

FW6

Description

None

Visual (Auto reset)

FPC Visual (Auto reset)

Visual Electrical Din Plug

FPC Electrical Din Plug

FPC Electronic L.E.D.

SYMBOLOF3

DescriptionNitrileFluoroelastomer*

PortsIndicator OptionsSeals

Table 1

SYMBOL12

DescriptionSingle LengthDouble Length

Housing Length

Table 3

Symbol18P28P38P

Model Number

Table 2 Table 5 Table 7

SYMBOL5098X

Description3.5 bar7.0 barNo bypass

Bypass Indicator Setting

Table 6

SYMBOLIII

DescriptionNoneNo Bypass

Options

Table 8

Applied to the filter assembly by ParkerFiltration.

Design Number

Table 9

Note: Filter assemblies ordered from the Part Number Matrix below are on extended lead times.Where possible, please make your selection from the table above.

Table 4

Average filtration ratio ß (ISO 16889) / particle size µm(c)

2 10 75 100 200 1000

N/A N/A N/A N/A N/A 4.5

N/A N/A 4.5 5 6 7

N/A 6 8.5 9 10 12

6 11 17 18 20 22

CODE

02Q

02QH

05Q

05QH

10Q

10QH

20Q

20QH

Degree of Filtration

110

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 110

Page 14: H600/H1000 Series - Winkler-Stiefel

7000 SeriesHigh Pressure Filters

Max 450 l/min - 420 bar

Global Filtration Technology

FEATURING

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 111

Page 15: H600/H1000 Series - Winkler-Stiefel

With the courtesy of:Kalmar Industries Inc.

With the courtesy of:Ponsse Oyj

High Pressure Filters7000 Series

TYPICAL APPLICATIONS

Forestry Equipment

Industrial Power Units

Pulp and Paper

Port Handling Equipment

Mining and Quarrying Equipment

The Parker Filtration 7000 Series HighPressure Filter Range.

High quality 420 bar in-line pressure

filters designed to offer high levels of

protection at flows up to 450 l/min

Dirt sensitive systems can be protected

with confidence using the 7000 Series

high pressure filters.

TYPICAL APPLICATIONS

112

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 112

Page 16: H600/H1000 Series - Winkler-Stiefel

High Pressure Filters7000 Series

SPECIFICATION

Assembly:In-line filter

Operating Pressure:Max 420 bar, type 7008: 350 bar, filter housing pressure pulsefatigue tested: 106 pulses 0-414 bar

Connections:Threads G1, G11/4, G11/2 (ISO 228/1) or flanges 11/2” SAE 3000psi, 11/2 SAE 6000 psi, 11/4” SAE 6000 psi

Seal Material:Nitrile (ordering B code) or Fluoroelastomer (ordering code V)

Operating Temperature Range:-20° to +100°C

Degree of Filtration:Determined by multipass test according to ISO 16889

Filtration Media:Microglass III supported with epoxy coated metal wire mesh orEcoglass III supported with plastic net (no metallic parts)(See table 2)

Flow Fatigue Characteristics:Filter media is supported so that the optimal fatigue life isachieved (ISO 3724)

Bypass Valve:Opening pressure 3.5 bar or optionally no bypass valve

Indicator Options:Indicating differential pressure:2.5 ± 0.2 bar or 7.0 ± 0.5 bar; 2.5 bar indicators to be used with3.5 bar bypass valve and 7.0 bar indicators with no bypass option

– electronic indicator FPC.F (10 to 36 VDC)– electrical indicator FPC.T (max 250 VAC)– visual indicator (FPC.V)

Indicator Housing:Standard material brass. Max torque 15Nm (11.25 Ft lbs)

Filter Housing:Head material, cast iron (GSI). Bowl material steel. Max torque 40Nm (30 Ft lbs)

Filter Element; and Collapse Ratings:7000 Series (Q0XX)Microglass III media, end cap material reinforced composite(code K) and metal inner core. Collapse rating 20 bar (ISO2941).

7000 Eco (QEXX)Ecoglass III media, end cap material reinforced composite (codeK), no metallic parts. Filter element can only be used together withre-usable FEA Eco-adaptor. Collapse rating 10 bar (ISO 2941).

Note: Ecoglass III elements contributes to ISO 14001 quality standards

7000 High Collapse Element (A0XX)(to be used when no bypass function in filter housing)Microglass III media supported with epoxy coated steel wire onupstream and stainless steel wire on downstream side. End cap material

With the courtesy of:Sandvik Tamrock

113

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 113

Page 17: H600/H1000 Series - Winkler-Stiefel

High Pressure Filters7000 Series

SPECIFICATION

7005700670077008

116 (4.57)208 (8.19)329 (12.95)428 (16.85)

249 (9.80)342 (13.46)462 (18.19)562 (22.12)

295 (11.61)390 (15.35)510 (20.08)610 (24.01)

235 (9.25)330 (13.00)450 (17.72)550 (21.65)

420 bar(6000 psi)

350 bar (5000 psi)

G1, G11/4 or G11/2

Flange: SAE 11/2 3000 psiFlange: SAE 11/2 6000 psiFlange: SAE 11/4 6000 psi

TYPE A B B B M AX WORKING PORTPRESSURE D(block

assembly) L PORTT PORT

BLOCK ASSEMBLY T PORT L PORT

62(2.44)

129(5.08)

60

B

41 HEX(1.61)

A

OUT

IN

D

137(5.39)

43(1.69)

M10 DEPTH 20 (0.78)

NOTE: NOFASTENING HOLESWITH SAEFLANGEOPTION

OUT IN

D D

OPTION (FOR ALL MODELS)PLUG M12x1.5

PLUG M12x1.5

M10 DEPTH 10

B

VENT PORT

p INDICATOR

30(1.18)

140

INTERNAL DIA. 32/EXTERNAL DIA. 41

4 MOUNTING HOLES 21 DIA.

OUTLET

O-RING SIZE 220

52(2.04)

190(7.48)

58

B

INLET

60(2.36) 41 HEX

(1.61)

137(5.39)

144

(5.6

7)

100

(3.9

4)

56(2.20)

OPTIONALINDICATORPORT

D

Ø103(4.05)

142(5.60)

mm(inches)

953.74

43(1.69)

114

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 114

Page 18: H600/H1000 Series - Winkler-Stiefel

Electronic & Electrical DifferentialPressure Indicator

CODE FPC.F & FPC.T

Visual DifferentialPressure Indicator

CODE FPC.V

High Pressure Filters7000 Series

INDICATOR DETAILS

70(2.75) 29

(1.14)

N/A

N/A

FPC.F25.BM

FPC.T25.VM

FPC.V25.BM

FPC.F70.BM

FPC.T70.VM

FPC.V70.BM

Option Description Connection/Voltage Wiring P/N

F25

T25

V25

F70

T70

V70

Electronic Indicator(2.5 bar)

Electrical Indicator(2.5 bar)

Visual Indicator(2.5 bar)

Electronic Indicator(7.0 bar)

Electrical Indicator(7.0 bar)

Visual Indicator(7.0 bar)

+10 to 36 VDC

Max 250 VACMax 250 VDC

N/A

+10 to 36 VDC

Max 250 VACMax 250 VDC

N/A

Load

Load

+V

0Vmax 300 mA -10...36 VDC

+10...36 VDC

3

1

2

4

FPC.FNPNNormallyopen(N.O.)

Load

Load

+V

0Vmax 300 mA -10...36 VDC

+10...36 VDC

3

1

2

4

FPC.FPNPNormallyopen(N.O.)

Load

Load

+V

0Vmax 300 mA -10...36 VDC

+10...36 VDC

3

1

2

4

FPC.FNPNNormallyopen(N.O.)

Load

Load

+V

0Vmax 300 mA -10...36 VDC

+10...36 VDC

3

1

2

4

FPC.FPNPNormallyopen(N.O.)

NoConnect

P1-P2

Pin 2 3 1

COM

Indi

catio

n (N

.O.)

Norm

ally

Clos

ed (N

.C.)

NoConnect

P1-P2

Pin 2 3 1

COM

Indi

catio

n (N

.O.)

Norm

ally

Clos

ed (N

.C.)

Note: For full indicator specifications see Section 6.

115

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 115

Page 19: H600/H1000 Series - Winkler-Stiefel

7005 Series with Microglass III Elements

7007 Series with Microglass III Elements

7000 Series Filter Housing

7006 Series with Microglass III Elements

7008 Series with Microglass III Elements

High Pressure Filters7000 Series

PRESSURE DROP CURVESIf the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows :-

p = ( p30 x viscosity of medium used) / 30 cSt

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

Q002

∆p (

bar

)

Q005 Q010 Q020

∆p (

psi

d)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

Q002

∆p (

bar

)

Q005

Q010

Q020

∆p (

psi

d)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

Q002

∆p (

bar

)

Q005

Q010

Q020 ∆p (

psi

d)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

GT24

GL24

GT16

GL16GT20

GL20Block

0 50 100 150 200 250 300 350 400 450 500

Flow (l/min)

∆p (

bar

)

0

0.2

0.4

1.4

1.2

1

0.6

0.8

Flow (US GPM)

0 53 79 106 13226

∆p (

psi

d)

0

2.9

5.8

11.6

17.4

20.3

14.5

11992663913

8.7

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

Q002

∆p (

bar

) Q005Q010

Q020 ∆p (

psi

d)

Flow (US GPM)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.30 13 26 39 53 66 79 92 106 119 132

116

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 116

Page 20: H600/H1000 Series - Winkler-Stiefel

High Pressure Filters7000 Series

PRESSURE DROP CURVESIf the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows :-

p = ( p30 x viscosity of medium used) / 30 cSt

7005 Series with Ecoglass III Elements

7007 Series with Ecoglass III Elements 7008 Series with Ecoglass III Elements

7006 Series with Ecoglass III Elements

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

QE02

∆p (

bar

)

QE05

QE10QE20

∆p (

psi

d)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

QE02

∆p (

bar

)

QE05QE10

QE20

∆p (

psi

d)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500Flow (l/min)

QE02

∆p (

bar

) QE05

QE10

QE20

∆p (

psi

d)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

0

0.2

0.4

0.6

0.8

1

1.2

1.4

0 50 100 150 200 250 300 350 400 450 500

Flow (l/min)

QE02

∆p (

bar

) QE05

QE10

QE20

∆p (

psi

d)

0

2.9

5.8

8.7

11.6

14.5

17.4

20.3

Flow (US GPM)

0 13 26 39 53 66 79 92 106 119 132

117

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 117

Page 21: H600/H1000 Series - Winkler-Stiefel

Part Number

L-PORT

FF7005.Q005.BS35.GL16

FF7005.Q005.BS35.GL20

FF7005.Q010.BS35.GL16

FF7005.Q010.BS35.GL20

FF7005.Q020.BS35.GL16

FF7005.Q020.BS35.GL20

FF7006.Q005.BS35.GL16

FF7006.Q005.BS35.GL20

FF7006.Q010.BS35.GL16

FF7006.Q010.BS35.GL20

FF7006.Q020.BS35.GL16

FF7006.Q020.BS35.GL20

FF7007.Q005.BS35.GL20

FF7007.Q005.BS35.GL24

FF7007.Q010.BS35.GL20

FF7007.Q010.BS35.GL24

FF7007.Q020.BS35.GL20

FF7007.Q020.BS35.GL24

FF7008.Q005.BS35.GL24

FF7008.Q010.BS35.GL24

FF7008.Q020.BS35.GL24

T-PORT

FF7005.Q005.BS35.GT16

FF7005.Q005.BS35.GT20

FF7005.Q010.BS35.GT16

FF7005.Q010.BS35.GT20

FF7005.Q020.BS35.GT16

FF7005.Q020.BS35.GT20

FF7006.Q005.BS35.GT20

FF7006.Q010.BS35.GT20

FF7006.Q010.BS35.GT24

FF7006.Q020.BS35.GT20

FF7006.Q020.BS35.GT24

FF7007.Q005.BS35.GT24

FF7007.Q010.BS35.GT24

FF7007.Q020.BS35.GT24

FF7008.Q005.BS35.GT24

FF7008.Q010.BS35.GT24

FF7008.Q020.BS35.GT24

Flow (l/min)

90

90

120

120

140

140

150

150

200

220

220

240

200

220

240

300

240

380

250

380

450

90

90

120

120

140

140

150

200

230

220

270

220

270

300

250

280

320

Media Rating

Q005

Q005

Q010

Q010

Q020

Q020

Q005

Q005

Q010

Q010

Q020

Q020

Q005

Q005

Q010

Q010

Q020

Q020

Q005

Q010

Q020

Q005

Q005

Q010

Q010

Q020

Q020

Q005

Q010

Q010

Q020

Q020

Q005

Q010

Q020

Q005

Q010

Q020

Ports

G1

G11/4

G1

G11/4

G1

G11/4

G1

G11/4

G1

G11/4

G1

G11/4

G11/4

G11/2

G11/4

G11/2

G11/4

G11/2

G11/2

G11/2

G11/2

G1

G11/4

G1

G11/4

G1

G11/4

G11/4

G11/4

G11/2

G11/4

G11/2

G11/2

G11/2

G11/2

G11/2

G11/2

G11/2

Replacement Elements

FC7005.Q005.BK

FC7005.Q005.BK

FC7005.Q010.BK

FC7005.Q010.BK

FC7005.Q020.BK

FC7005.Q020.BK

FC7006.Q005.BK

FC7006.Q005.BK

FC7006.Q010.BK

FC7006.Q010.BK

FC7006.Q020.BK

FC7006.Q020.BK

FC7007.Q005.BK

FC7007.Q005.BK

FC7007.Q010.BK

FC7007.Q010.BK

FC7007.Q020.BK

FC7007.Q020.BK

FC7008.Q005.BK

FC7008.Q010.BK

FC7008.Q020.BK

FC7005.Q005.BK

FC7005.Q005.BK

FC7005.Q010.BK

FC7005.Q010.BK

FC7005.Q020.BK

FC7005.Q020.BK

FC7006.Q005.BK

FC7006.Q010.BK

FC7006.Q010.BK

FC7006.Q020.BK

FC7006.Q020.BK

FC7007.Q005.BK

FC7007.Q010.BK

FC7007.Q020.BK

FC7008.Q005.BK

FC7008.Q010.BK

FC7008.Q020.BK

PREFERRED PRODUCTS TABLEThe following standard filters are supplied with 3.5 bar bypass and Nitrile seals.NB An indicator if required should be ordered separately.

High Pressure Filters7000 Series

118

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 118

Page 22: H600/H1000 Series - Winkler-Stiefel

PREFERRED PRODUCTS TABLE

High Pressure Filters7000 Series

Part Number

L-PORT

FF7005.QE05.BS35.GL16

FF7005.QE05.BS35.GL20

FF7005.QE10.BS35.GL16

FF7005.QE10.BS35.GL20

FF7005.QE20.BS35.GL16

FF7005.QE20.BS35.GL20

FF7006.QE05.BS35.GL16

FF7006.QE05.BS35.GL20

FF7006.QE10.BS35.GL16

FF7006.QE10.BS35.GL20

FF7006.QE20.BS35.GL16

FF7006.QE20.BS35.GL20

FF7007.QE05.BS35.GL20

FF7007.QE05.BS35.GL24

FF7007.QE10.BS35.GL20

FF7007.QE10.BS35.GL24

FF7007.QE20.BS35.GL20

FF7007.QE20.BS35.GL24

FF7008.QE05.BS35.GL24

FF7008.QE10.BS35.GL24

FF7008.QE20.BS35.GL24

T-PORT

FF7005.QE05.BS35.GT16

FF7005.QE05.BS35.GT20

FF7005.QE10.BS35.GT16

FF7005.QE10.BS35.GT20

FF7005.QE20.BS35.GT16

FF7005.QE20.BS35.GT20

FF7006.QE05.BS35.GT20

FF7006.QE10.BS35.GT20

FF7006.QE10.BS35.GT24

FF7006.QE20.BS35.GT20

FF7006.QE20.BS35.GT24

FF7007.QE05.BS35.GT24

FF7007.QE10.BS35.GT24

FF7007.QE20.BS35.GT24

FF7008.QE05.BS35.GT24

FF7008.QE10.BS35.GT24

FF7008.QE20.BS35.GT24

Flow (l/min)

90

90

120

120

140

140

150

150

200

220

220

240

200

220

240

300

240

380

250

380

450

90

90

120

120

140

140

150

200

230

220

270

220

270

300

250

280

320

Media Rating

Q005

Q005

Q010

Q010

Q020

Q020

Q005

Q005

Q010

Q010

Q020

Q020

Q005

Q005

Q010

Q010

Q020

Q020

Q005

Q010

Q020

Q005

Q005

Q010

Q010

Q020

Q020

Q005

Q010

Q010

Q020

Q020

Q005

Q010

Q020

Q005

Q010

Q020

Ports

G1

G11/4

G1

G11/4

G1

G11/4

G1

G11/4

G1

G11/4

G1

G11/4

G11/4

G11/2

G11/4

G11/2

G11/4

G11/2

G11/2

G11/2

G11/2

G1

G11/4

G1

G11/4

G1

G11/4

G11/4

G11/4

G11/2

G11/4

G11/2

G11/2

G11/2

G11/2

G11/2

G11/2

G11/2

Replacement Elements

FC7005.QE05.BK

FC7005.QE05.BK

FC7005.QE10.BK

FC7005.QE10.BK

FC7005.QE20.BK

FC7005.QE20.BK

FC7006.QE05.BK

FC7006.QE05.BK

FC7006.QE10.BK

FC7006.QE10.BK

FC7006.QE20.BK

FC7006.QE20.BK

FC7007.QE05.BK

FC7007.QE05.BK

FC7007.QE10.BK

FC7007.QE10.BK

FC7007.QE20.BK

FC7007.QE20.BK

FC7008.QE05.BK

FC7008.QE10.BK

FC7008.QE20.BK

FC7005.QE05.BK

FC7005.QE05.BK

FC7005.QE10.BK

FC7005.QE10.BK

FC7005.QE20.BK

FC7005.QE20.BK

FC7006.QE05.BK

FC7006.QE10.BK

FC7006.QE10.BK

FC7006.QE20.BK

FC7006.QE20.BK

FC7007.QE05.BK

FC7007.QE10.BK

FC7007.QE20.BK

FC7008.QE05.BK

FC7008.QE10.BK

FC7008.QE20.BK

ECO Range

Note: Filter assemblies ordered from the Part Number Matrix on the next page are on extendedlead times. Where possible, please make your selection from the tables above and on theprevious page.

119

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 119

Page 23: H600/H1000 Series - Winkler-Stiefel

FB block assembly XC32

High Pressure Filters7000 Series

Filter Assembly:

Filter Element:

p Indicator:

Eco-adaptor:

Seal Kit:

FEA

FPC

FC

FF** Block assy = FB

PART NUMBER MATRIXTable 1 Table 2 Table 3 Table 4 Table 5 Table 6

Table 1 Table 2 Table 3

Table 8 Table 7M

Table 1 Table 3

FD7000-Table 3

Indicator Type Options*

Visual indicator2.5 bar

Electronic indicator2.5 bar (10...36 VDC)

Electrical indicator2.5 bar (max 250 VAC)

Visual indicator7.0 bar

Electronic indicator7.0 bar (10...36 VDC)

Electrical indicator7.0 bar (max 250 VAC)

CODE

V25

F25

T25

V70

F70

T70

CODE3500

Connection Type, T-model3.5 barNO BYPASS

CODEBV

Seal MaterialNitrileFluoroelastomer

CODEL

GL16GL20GL24SL24VL24VL20

TGT16GT20GT24ST24VT24VT16

Connection Type Options,Filter HousingG1 ThreadG11/4 ThreadG11/2 ThreadFlange 11/2” SAE, 3000 psiFlange 11/2” SAE, 6000 psiFlange 11/4” SAE, 6000 psi

CODE*

A005A010A020

QE02QE05QE10QE20

Q002Q005Q010Q020

Average filtration ratio ß (ISO 16889) / particle size µm(c)2 10 75 100 200 1000

N/A N/A N/A N/A N/A 4.5N/A N/A 4.5 5 6 7N/A 6 8.5 9 10 126 11 17 18 20 22

CODE7005700670077008

Element Length116mm208mm329mm428mm

p Indicator

Bypass Valve Filter Connection

Seal Type (Filter)Degree of FiltrationFilter Type

Table 1 Table 2 Table 3

Table 5

CODEBV

Indicator OptionV25, F25, V70, F70T25, T70

Seal MaterialNitrileFluoroelastomer

Seal Type (Indicator)*

Table 7

*Standard options.For other options contact Parker Filtration

ORDERING EXAMPLES:Please note that when choosing the right size of the filter assembly, choose first the desired connectionsand the degree of filtration. The element length (Table 1) can be decided last according to the p demandsof the system.

COMPLETE FILTER: FF7007.Q010.BS35.GL20This code is for complete filter assembly with 329mm long element made of Microglass III/Q010 filtermedia, supported with epoxy coated metal wire mesh and metal inner core. Seal material is nitrile and thefilter housing is steel. Filter includes 3.5 bar bypass valve and G11/4 threads for connection. Degree offiltration see Table 2.

FILTER ELEMENT: FC7005.QE02.VKThis filter element is 116mm long with FEA adaptor and it is made of Ecoglass III/QE02 filter media. Theseal material is fluoroelastomer and element caps are of re-inforced composite.

For additional drain and vent plug options, please contact Parker Filtration.

Table 4

–IS

Standard on topOn side only

Indicator Port Position T-Model

Table 6

Table 8

K (S FOR 210 BAR ELEMENT)

S —

*Note: When using Eco-element Eco-adapter FEA is required *Q0XX = Microglass III: conventional element, collapse rating 20 bar

QEXX = Ecoglass III: Eco-element without metallic parts, collapse rating 10 barA0XX = Microglass III: high collapse element, collapse rating 210 bar

*7.0 bar indicator for use without bypass valve

120

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 120

Page 24: H600/H1000 Series - Winkler-Stiefel

HPA SeriesMini Pressure Filters

Max 33 l/min - 280 bar

Global Filtration Technology

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 127

Page 25: H600/H1000 Series - Winkler-Stiefel

Mini Pressure FiltersHPA Series

TYPICAL APPLICATIONS

Low Flow Servo Systems

Pilot Lines

Small Mobile Equipment

Lubrication Systems

High Pressure Water Systems

The Parker Filtration HPA Series MiniPressure Filters.

Small and easy to install, the Mini Pressure

Filter is a robust solution to the low flow

applications that larger filters are unable to

effectively handle.

Made from high strength brass stampings and

supplied with a wide range of media options,

reliable, high efficiency protection is the result

of using the Mini Pressure Filter.

TYPICAL APPLICATIONS

The machine pictured is the“Compact 40” precinct

sweeper from the JohnstonCompact range of self

propelled suction sweepers.Photograph courtesy of

Johnston Engineering Ltd.

Alternative head mounting.For details please contactParker Filtration.

Photographs courtesy ofNifty Lift Ltd.

128

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 128

Page 26: H600/H1000 Series - Winkler-Stiefel

Mini Pressure FiltersHPA Series

SPECIFICATION

INSTALLATION DETAILS (FOR NEW HEAD DETAILS CONSULT PARKER FILTRATION)

Construction:Brass stampings

Max. working pressure:280 bar

Working temperature:-30°C to +90°C

Thread:G1/4 and G3/8

Filtration media:Microglass III; see Table A10µ, 25µ, 40µ, 80µ and 125µ (nominal) stainless steel

Seals:Nitrile/Nitrile composite

Weight:Length 1: 0.88 KgLength 2: 1.2 Kg

Note: For Length 1 and Length 2 filter housing and element media pressure drop against flow curves consult Parker Filtration.

Length 1 Length 2

CIRCUIT SYMBOL

29

22 A/F HEX

6248

8237

1611.1

62.7

INLET PORT G1/4 OUTLET PORT G1/419

MIN

IMUM

FO

RBO

WL

REM

OVA

L

63

21 A/F

G3/8

Ø48

Ø62

1913

8

37

11

129

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 129

Page 27: H600/H1000 Series - Winkler-Stiefel

PREFERRED PRODUCTS TABLE

Mini Pressure FiltersHPA Series

Consult Parker Filtration for

flow specifications

HPR.1229

HPR.1329

HPR.1429

HPR.1529

HPR.1629

HPR.1729

HPR.1829

HPR.1929

2µ Absolute pressure filter

3µ Absolute pressure filter

5µ Absolute pressure filter

10µ Absolute pressure filter

25µ Absolute pressure filter

40µ Absolute pressure filter

80µ Absolute pressure filter

125µ Absolute pressure filter

HPA.2225.100

HPA.2325.100

HPA.2425.100

HPA.2525.100

HPA.2625.100

HPA.2725.100

HPA.2825.100

HPA.2925.100

Part Number Description Replacement Element

Consult Parker Filtration for

flow specifications

2µ Absolute pressure filter

3µ Absolute pressure filter

5µ Absolute pressure filter

10µ Absolute pressure filter

25µ Absolute pressure filter

40µ Absolute pressure filter

80µ Absolute pressure filter

125µ Nominal pressure filter

HP.1229.10

HP.1229.25

HP.1229.40

HP.1229.125

HPR.1219

HPR.1319

HPR.1419

HPR.1519

HPR.1619

HPR.1719

HPR.1819

HPR.1919

HPA.1219.100

HPA.1319.100

HPA.1419.100

HPA.1519.100

HPA.1619.100

HPA.1719.100

HPA.1819.100

HPA.1919.100

Part Number Description Supersedes Replacement Element

Length 2 G3/8 Port, 5 bar by-pass

Length 1 G1/4 Port No by-pass

Note: Length 1, 10 bar by-pass version available – contact Parker Filtration.

Average filtration Beta Ratio (ISO 16889)

2 10 75 100 200 1000

– – – – – 4.5

– – 3.0 – – –

– – 4.5 5.0 6.0 7.0

– 6.0 8.5 8.0 10.0 12.0

– – – – – –

– – 40.0 – – –

– – 80.0 – – –

– – 125.0 – – –

ASSEMBLY NUMBER

HPA.1219.100

HPA.1319.100

HPA.1419.100

HPA.1519.100

HPA.1619.100

HPA.1719.100

HPA.1819.100

HPA.1919.100

Degree of FiltrationTable A

130

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 130

Page 28: H600/H1000 Series - Winkler-Stiefel

SH100 SeriesHigh Pressure Filters

Max 100 l/min - 690 bar

Global Filtration Technology

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 131

Page 29: H600/H1000 Series - Winkler-Stiefel

High Pressure In-Line Stainless Steel FiltersSH100 Series

TYPICAL APPLICATIONS

Hydraulic Start-Up Systems

Flushing Filter

Offshore Cranes

Oil/Gas Industry

Mine Hunters

The Parker Filtration Model SH100 HighPressure In-Line Stainless Steel Filters.

The stainless steel SH100 high-pressure filter is

designed for heavy-duty and critical applications. It

features a flow capacity of 100 l/min at 690 bar working

pressure. A wide range of elements, including high-

strength versions is available. The elements and filter

media used include high-quality materials such as HPFE

glass fibre and stainless steel mesh as well as high

strength mesh cleanable elements and high strength fibre

disposable elements.

TYPICAL APPLICATIONS

132

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 132

Page 30: H600/H1000 Series - Winkler-Stiefel

High Pressure In-Line Stainless Steel FiltersSH100 Series

SPECIFICATION

Assembly:In-line filter

Operating Pressure:Max 690 bar

Connections:Threads G1/2, G3/4” (ISO228), 1/2”NPT, 3/4”NPT, 3/4” SAE

Seal Material:Nitrile, Neoprene, Fluoroelastomer

Operating Temperature Range:-40°C to 100°C

Degree of Filtration:Determined by multipass test according to ISO 16889

Filtration Media:HPFE glass fibre GDH multi layer glass fibre or StainlessSteel mesh

Flow Fatigue CharacteristicsFilter media is supported so that the optimal fatigue life isachieved

Element Collapse Rating:20 bar (ISO 2941) or 210 bar for high strength version

Bypass Setting:3.5 bar ± 0.2

Differential Pressure Indicator:2.8 barDifferential indicator visualDifferential indicator electrical

Filter Housing:Stainless steel

Filter Element:Element with steel end caps

Options:High strength elements

40(1

.57)

34(1

.34)

22.5

(0.8

8)

Ø100 (3.94)

30 sq.

Ø95(3.74)

PORT TYPE ‘B’ILLUSTRATED

LEN

GT

H 1

– 1

46 (

5.75

)

LEN

GT

H 2

– 2

02 (

7.95

)

13(0.51)

1.5(0.06)

64 (2.52)

16.5

(0.6

5)14

(0.5

5)

93 A

/F (

3.66

)

3 HOLES FOR FIXING BOLTSM8 x 12 DEEP ON FILTERS WITH BSPPORTS AND 5/16” UN x 12 DEEP ONFILTERS WITH SAE OR NPT PORTS

mm(inches)

133

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 133

Page 31: H600/H1000 Series - Winkler-Stiefel

High Pressure In-Line Stainless Steel FiltersSH100 Series

PRESSURE DROP CURVES

Flow (l/min)

∆p (

bar

)

0

0.5

1

1.5

2

2.5

3

3.5

4

0 10 20 30 40 50 60 70 80

Flow (US GPM)

0 3 5 8 11 13 16 18 21

∆p (

psi

d)

0

7.3

14.5

21.8

36.3

43.5

50.8

58.0

29.0GDH1

GDH3

GDH6 GDH10

GDH20

Flow (l/min)

∆p (

bar

)

0

0.5

1

1.5

2

2.5

3

3.5

0 20 40 60 80 100 120

1/2"BSP

3/4"BSP

∆p (

psi

d)

0

7.3

14.5

21.8

29.0

36.3

43.5

50.8

Flow (US GPM)

0 5 11 16 21 26 31

0

0.5

1

1.5

2

2.5

3

3.5

0 10 20 30 40 50 60 70 80 90 100

GDH1

GDH3

GDH6 GDH10

GDH20

∆p (

bar

)

Flow (l/min)

Flow (US GPM)

0 3 5 8 11 13 16 18 21 24 26

∆p (

psi

d)

0

7.3

14.5

21.8

29.0

36.3

43.5

50.8

Flow (l/min)

∆p (

bar

)

0

0.20.4

0.6

0.81

1.2

1.4

1.61.8

2

0 20 40 60 80 100 120

01

10

Flow (US GPM)

0 5 11 16 21 26 31

∆p (

psi

d)

0

5.8

11.5

17.4

23.2

29.026.1

20.3

14.5

8.7

2.9

Flow (l/min)

∆p (

bar

)

0

0.5

1

1.5

2

2.5

3

0 10 20 30 40 50 60 70 80

FF 10

Flow (US GPM)

0 3 5 8 11 13 16 18 21

∆p (

psi

d)

0

7.3

14.5

21.8

29.0

43.5

36.3

Flow (l/min)

∆p (

bar

)

0

0.5

1

1.5

2

2.5

0 20 40 60 80 100 120

FF

10

Flow (US GPM)

0 5 11 16 21 26 31

∆p (

psi

d)

0

7.3

14.5

21.8

29.0

36.3

Flow (l/min)

∆p (

bar

)

0

0.5

1

1.5

2

2.5

0 20 40 60 80 100 120

01

10

Flow (US GPM)

0 5 11 16 21 26 31

∆p (

psi

d)

0

7.3

14.5

21.8

29.0

36.3

Element HD 100-Series Type 7 L1

Element HD 100-Series Type 7 L2

HD 100-Series Empty Housing

Element HD 100-Series L2 High Strength Type-4

Element HD 100-Series L2 High Strength Type-5

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

1.8

0 10 20 30 40 50 60 70 80

∆p (

bar

)

∆p (

psi

d)

Flow (US GPM)

Flow (l/min)

L1

L2

0 8 18 213 5 11 13 16

0

5.8

8.7

11.5

20.3

23.2

26.1

17.4

14.5

2.9

Element HD 100-Series L1 & L2 Type-9

Element HD 100-Series L1 High Strength Type-4

Element HD 100-Series L1 High Strength Type-5

134

03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 134

Page 32: H600/H1000 Series - Winkler-Stiefel

Table 5ATable 5

Ordering Code175A2L35-NZ121S175A2L35-NZ122S175A2L35-NZ123S175A2L35-DZ221S175A2L35-DZ222S175A2L35-DZ223S

Ordering Code Flow (l/min)505050100100100

Flow (l/min) Micron RatingGDH 06GDH 10GDH 20GDH 06GDH 10GDH 20

Media Rating Ports1/2” NPT1/2” NPT1/2” NPT3/4” NPT3/4” NPT3/4” NPT

Ports IndicatorVisualVisualVisualVisualVisualVisual

Indicator Replacement Elements170Z121A170Z122A170Z123A170Z221A170Z222A170Z223A

Replacement Elements

PREFERRED PRODUCTS TABLE

High Pressure In-Line Stainless Steel FiltersSH100 Series

ORDERING EXAMPLE

Std 2 Std 8 9 10 4

1 2 3 4 5 5A 6 Std 7 8 9 10 Std

1 7 5 A 3 C 35 – B Z 1 22 S

1 7 0 Z 1 22 A

Element TypeHigh strength cleanable Stainless steel*High strength inorganic fibre disposableInorganic fibre disposableCorrosion resistant mesh (cleanable)*

CODE4579

CODE1

HousingModel SH100

Element TypeFilter Type

Table 1 Table 2

VarietyStainless steel

CODE5

Filter Material

Table 3

No bypass port machinedSpool type bypass valveSpool type bypass valveNo bypass valve

Spool type bypass valve

No bypass valve

No indicator / No bypass valveNo indicatorStandard visual indicatorVisual indicator with memory (Latch out)Electrical IDN 43650 28V=/ 250 V ~ No lampsElectrical visual indicator 250 V ~ Green lamps N.C.Electrical visual indicator 250 V ~ Red lamps N.O.Electrical visual indicator 110 V ~ Green lamps N.C.Electrical visual indicator 110 V ~ Red lamps N.O.Electrical visual indicator 28 V = Green lamps N.C.Electrical visual indicator 28 V = Red lamps N.O.

0124

3

5

NNNLTHKCMER

Bypass Indicators

Element typesMineral oil only(Only available on filter type ‘7’)All fluids exc. phos. esters,water glycols and ammonia containing fluidsHFC-FluidsPlease contact Parker Arlon before utilisationAmmonia containing fluidsPlease contact Parker Arlon before utilisationPhosphate estersPlease contact Parker Arlon before utilisation

CODE

L

Z

*T

*F

*S

10 & 20µ only

All ratings

All ratings

All ratings

All ratings

Element Information

Table 8

Seal MaterialNitrile (NBR)Ethylene Propylene (EP)Fluoroelastomer (FPM)

CODEABH

Seal Type

Table 4

Bypass differential pressure settingNo bypass / No indicatorBypass setting 3.5 bar

CODE0035

Bypass Valve

Table 6

PortsISO 228- G1/2 (1/2” BSP)ISO 228- G3/4 (3/4” BSP)1/2” NPT3/4” NPT11/16” SAE (11/16”-12 UN-2B)

CODEBENDJ

Filter Connection

Table 7

Element lengthLength 1Length 2

CODE12

Element Length

Table 9

Element type Filtration Fineness (ßx≥75)5 3µ4 6µ4 or 5 15µ9 40µ7 GDH17 GDH37 GDH67 GDH107 GDH20

CODEFF0110401920212223

Filter Media

Table 10

* Only valid with special cleaning routine.

Note: Filter assemblies ordered from the Part Number Matrix below are on extended lead times.Where possible, please make your selection from the table above.

* Specials on request. Please consult Parker Filtration.

Element

Assembly

Average filtration Beta Ratio (ISO 16889) / particle size µm(c)

2 10 75 100 200 1000

N/A 3.0 4.1 4.4 4.9 6.7

N/A 4.0 6.7 7.0 7.9 10.0

3.1 6.2 9.9 10.4 11.6 14.6

6.7 12.6 17.8 18.5 20.0 22.6

CODE

GDL3/GDH3

GDL6/GDH6

GDL10/GDH10

GDL20/GDH20

Degree of FiltrationTable A

135