    Training:Use of membranes

    in the maple syrup field

    Prepared by:

    Rock Gaulin

    Pierre Courtois

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    2/31

    Membranes used in maple farms

    Factors influencing membrane clogging

    When to clean membranes

    Cleaning procedures

    High Brix concentration

    Membrane storage at season end

    2

    Training plan

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    3/31

    3

    Membranes used inmaple farms

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    4/31

    4

    Membranes used in maple farms

    Max.cleaning

    temp.

    Max.cleaning

    pH

    Max.cleaning

    temp.

    Max.cleaning

    pHPressure

    Permeateflow

    produced(GPD)

    Max.operatingpressure

    MaterialRejection

    rate

    Activesurface(sqft)

    Membraneadaptordiameter

    Filmtec Bw 30 45C 2-10.5 35C 1-12 225 psi 10 500 600 psiPolyamideThin-Film

    Composite99.0% 440 1-1/4"

    Filmtec Mark I 45C 2-10.5 35C 1-12 Na Na 600 psiPolyamideThin-Film

    Composite

    ND* 450 1-1/4"

    Filmtec Nf 270 40C 2-10 35C 1-11 75 psi 12 500 600 psiPolyamideThin-Film

    Composite50.0% 400 1-1/2"

    Filmtec Nf 90 45C 2-10.5 35C 1-12 75 psi 7 500 600 psiPolyamideThin-Film

    Composite85-95.0% 400 1-1/2"

    Filmtec Xle 440 45C 2-10.5 35C 1-12 225 psi 12 700 600 psiPolyamideThin-Film

    Composite99.0% 440 1-1/2"

    Hydranautics PVD1 40C 2-9 35C 2-9.5 Na 11 000 400 psiPolyvinylAlcohol

    Derivative80.0% 365 1-1/2"

    H2OInnovation

    H2O 70 45C 2-12 35C 2-12 100 psi 13 000 600 psiPolyamideThin-Film

    Composite99.5% 400 1-1/4"

    The table above compares the different membranes used in the maple syrup industry. Pleasenote that the maximum cleaning pH depend on water temperature. For organic clogging, it hasbeen shown that a pH 12 cleaning is 9 times more efficient than a pH 11 cleaning.

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    5/31

    5

    Factors influencing membraneclogging

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    6/31

    Non-observance of the membrane s recovery rate

    Non-observance of the permeate volume producedper membrane

    Maintenance of pre-filtration cartridges

    Feed water quality

    Operating pressure

    6

    Factors influencing membrane clogging

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    7/31

    According to membrane manufacturers, a membrane mustoperate with a maximum recovery rate of 15% .

    RECIRCULATION or an increase in the NUMBER ofmembranes allows increasing the total recovery rate of a

    system without damaging the membranes.

    Recovery rate calculation:

    Recovery rate = Permeate flow/ Total Flow (Concentrate andPermeate) x 100 Ex: Permeate 10 Concentrate 5,

    10 /(5+10) = 0.66 x 100 = 66%

    7

    Non-observance of the membrane srecovery rate

    3 gpm

    70 gpm 7 gpm

    60 gpm

    10 gpm

    30 gpm

    40 gpm

    70gpm

    42 %

    70 %

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    8/31

    Non-observance of the membrane srecovery rate

    H2O Innovation recommends not to exceed 21 Brix in the concentrate.

    The more membranes a system contains, the higher the recovery rate can be.

    The table below gives a few examples. It is possible to exceed these criteria, butclogging will happen much faster.

    Please note that the operation of a system cannot be based on the concentrate sBrix concentration, as the latter varies according to feed water quality and watertemperature. The operation of a system must be made in accordance with therecovery rate.

    Number of serial membranes 1 2 3 4 5 6 7 8

    Maximum recommended recovery rate at 8C 75% 78% 80% 82% 84% 86% 87% 88%

    Concentration if inlet of 2 Brix 8.0 9.1 10.0 11.1 12.5 14.3 16.7 18.2Concentration if inlet of 2.5 Brix

    10.0 11.4 12.5 13.9 15.6 17.9 20.8 21Concentration if inlet of 3 Brix

    12.0 13.6 15.0 16.7 18.8 21.0 21.0 21

    8

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    9/31

    Membranes are designed to produce a maximum volume of Permeate perminute / day. The average lies around 450 gph.

    If this maximum volume is exceeded, clogging is accelerated exponentially.

    9

    Non-observance of the permeate volumeproduced per membrane

    -10%

    0%

    10%

    20%

    30%

    40%

    50%

    60%

    70%

    80%

    0 2 4 6 8 10 12 14

    Loss of production versusPermeate flow produced

    Gallons of permeate per minute per membrane

    Loss of production

    % per hour

    This is why it is important to balance

    the production flow of all membranes.

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    10/31

    When pre-filters reach a 40+ psi differential, bypass can happen and someparticles can settle on the membrane; clogging is then irreversible. It isimportant to use good quality cartridges; H2O Innovation recommends 3MPolyclean or Puretrex cartridges.

    10

    Maintenance of pre-filtration cartridges

    To enable longer intervals between replacements of filters, H2O Innovationrecommends to add a bag in series with the other cartridges. The cartridgelifetime will be increased up to 4 times.

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    11/31

    Maple water contains various micro-organisms (polysaccharides, bacterialmetabolites). These organisms fix on the membrane surface and create aglue which is called bio-film.

    The bio-film is very hard to remove with traditional cleaning products. Itrequires a radical treatment.

    To limit bio-film, it is important not to allow water to get warmer in basins.The higher the temperature in the basins, the fastest the cellular division.This is why it is important to rinse thoroughly your system after each use.

    11

    Feed water quality

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    12/31

    Contrary to popular belief, operating pressure isn t a factor of membrane

    clogging. But a misuse of the maximum recovery or volume principles canentail an increase in membrane pressure, which is often considered asbeing the problem, whereas it is only the result.

    The table below shows osmotic pressure versus feed water concentration.

    12

    The Osmotic pressure isthe minimum pressurenecessary to produce adrop of water at given

    concentration andtemperature.

    BrixConcentration

    Osmoticpressure (psi)

    3.5 % 40 psi

    8 % 100 psi

    12 % 145 psi

    14.5 % 185 psi

    17 % 225 psi

    20 % 275 psi

    25 % 380 psi

    30 % 500 psi

    Operating pressure

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    13/31

    13

    When to clean membranes?

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    14/31

    Here is an easy way to determine if your membranes need cleaning. Please

    note that it is important to know the initial PWP. (The initial PWP is measuredat the beginning of the season, and updated after each cleaning).

    PWP = Pure Water Permeability, i.e. the quantity of Permeate produced in apure water at given concentration and temperature.

    When the PWP reaches 15% , you have to initiate a cleaning sequence. If thePWP is over 20%, it will be hard to properly clean the membrane (see tablebelow).

    14

    Loss of Pure Water Permeability PWP

    0

    5

    10

    15

    20

    25

    PWP

    PEPPWP

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    15/31

    When to measure the PWP?

    It is recommended to measure the PWP after 6 hours of continuousoperation, or when operating pressure has increased by 20%, as well asat the beginning or at the end of each production period.

    Procedures:

    Rinse the membranes with permeate for 15 minutes or until theconductivity is less than 10 microsiemens. H2O Innovation recommendsrinsing with recirculation pumps, so that it takes less time.

    Adjust membrane pressure to 150 psi (H2O Innovation recommends a 150psi PWP); at 150 psi, the permeate flow is very close to the actualproduction flow.

    Read and note down the total permeate flow for each membrane ifpossible;.

    Read and note down the water temperature.

    Use the correction table to adjust your PWP to 13C.

    15

    PWP

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    16/31

    Example of data:

    PWPinitial = 25 gpm at 150 psi at 13C

    Current data: 150 psi, 14 gpm of permeate, 3C

    PWP = permeate flow/ temperature correction factor

    PWP = 14 gpm / 0.742 = 18.8 gpm (flow at 13 C)

    Yield loss calculation:

    100%-((PWP/PWPinital)) x 100) = yield rate in %

    ( 18.8 / 25) x 100 = 75.4 % of yield

    100 % 75.4 % = 24.6 yield loss in %

    In this case, a cleaning is essential because loss has exceeded 15%.

    16

    PWP Calculation

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    17/31

    PWP in cold water: 13C as reference temperature

    17

    Temperature Correction Factor

    TemperatureC

    CorrectionFactor

    TemperatureC

    CorrectionFactor

    0 0.672 13 1.000

    1 0.695 14 1.028

    2 0.718 15 1.055

    3 0.742 16 1.084

    4 0.766 17 1.112

    5 0.790 18 1.142

    6 0.816 19 1.170

    7 0.842 20 1.200

    8 0.866 21 1.229

    9 0.893 22 1.259

    10 0.919 23 1.289

    11 0.946 24 1.319

    12 0.973 25 1.350

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    18/31

    18

    Cleaning procedures

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    19/31

    19

    Standard cleaningNecessary tools:

    pH meter

    Conductivity meter

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    20/31

    Standard cleaning cycle

    Fill the cleaning tank

    Add 350 ml of Lavasol VII or 700 ml of Bio-Membrane for every 100 litresof permeate in the cleaning tank, or adjust the solution at pH 12 or (seetable to know cleaning temperatures for each membrane). Then, launchthe cleaning mode. To get an optimal cleaning, the flow must be fast so asto create a membrane washout effect. H2O Innovation recommends touse the pressure pump in cleaning mode so as to increase the flow(washout effect), but if your separator doesn t allow a cleaning under 100psi, the cleaning must be done without the pressure pump.

    Re-circulate the cleaning solution until temperature reaches a maximum of45 C (please validate with the informative table on membranes).

    Rinse the system for 15 minutes or until conductivity is less than 10microsiemens.

    Measure the PWP. If gains are not sufficient, you can clean again withLavasol VII or Bio-Membrane.

    20

    Standard cleaning

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    21/31

    Max.cleaning temp.

    Max.cleaning

    pH

    Max.cleaning

    temp.

    Max.cleaning

    pH

    Max.cleaning

    temp

    Max.cleaning

    pH

    Filmtec Bw 30 45 C 2-10.5 35C 1-12 25C 1-13

    Mark I 45 C 2-10.5 35C 1-12 25C 1-13

    Nf 270 40 C 2-10 35C 1-11 25C 1-12

    Nf 90 45 C 2-10.5 35C 1-12 25C 1-13

    Xle 440 45 C 2-10.5 35C 1-12 25C 1-13

    Hydranautics PVD1 40 C 2-9 35C 2-9.5 25C 2-10

    H2OInnovation

    H2O 70 45 C 2-12 35C 2-12 25C 1-12

    Informative table on membranes andcleaning tolerances

    21

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    22/31

    22

    Complete cleaning

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    23/31

    Fill the cleaning tank. Clean with Lavasol VII or Bio-Membrane at pH 12. After 5 minutes of cleaning, we recommend to measure pH and to add

    products if needed. When the membrane is filled with organic waste, the pHtends to decrease because the Bio-Membrane or Lavasol VII active agentbinds to this organic matter.

    Re-circulate the cleaning solution until temperature reaches 45C. Rinse the system.

    Measure the PWP. Clean with citric acid, 1 cup for each 40 litres of dead volume. Rinse the system. Measure the PWP. Clean with Oxysan, 700 ml for each 100 litres of total volume. Be careful not to

    exceed 23C. Soak the system with this solution, between 1 hour and 48 hours. (The longer

    the soaking time, the more efficient.) Rinse the system. Measure the PWP. Clean with Lavasol VII until temperature reaches 45C. Repeat cleanings with Lavasol VII and Oxysan until the PWP does not

    increase any more. Always end with a Lavasol VII cleaning.

    23

    Complete cleaning

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    24/31

    24

    High Brix concentration

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    25/31

    The table below shows profitability of a high Brix concentrate.

    25

    High Brix concentration

    Oil at $0.75/l

    Evaporatio

    ncost($/UKg

    al.ofsyrup)

    Evap. EE = 75%

    Brix

    Savings of $10.9 /UK gal. of syrup

    Savings of $1.6 /UK gal. of syrup

    Savings of $0.6 /UK gal. of syrup

    $3.2 / UK gal. $1.6 / UK gal. $1.0 / UK gal.

    Source: Center ACER

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    26/31

    To reach a high Brix concentration, you need to have a minimum numberof serial membranes on your system (see table). It is also possible to go 2or 3 times through the membranes with smaller devices.

    Please note that evaporation is not the same at 20 Brix and 8 Brix.

    The table above shows that a concentration of 20 Brix needs a minimumof 6 membranes if feed water is at 3 Brix.

    26

    High Brix concentration

    Number of serial membranes 1 2 3 4 5 6 7 8

    Maximum recommended recovery rate at 8C 75% 78% 80% 82% 84% 86% 87% 88%

    Concentration if inlet of 2 Brix 8.0 9.1 10.0 11.1 12.5 14.3 16.7 18.2Concentration if inlet of 2.5 Brix

    10.0 11.4 12.5 13.9 15.6 17.9 20.8 21Concentration if inlet of 3 Brix

    12.0 13.6 15.0 16.7 18.8 21.0 21.0 21

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    27/31

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    28/31

    1 system of 8 serial membranes with Booster Pump

    This kind of system is the most efficient. It allows a continuous operationwhile preventing bacteria from proliferating in the basins.

    Please note that for cleaning, the system shouldn t have more than 4serial membranes, otherwise the cleaning will be much less efficient.

    28

    High Brix concentration

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    29/31

    29

    Membrane storage

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    30/31

    At the end of the season, it is important to clean the membranes.

    After cleaning, the membrane must be stored in a wet place exempt ofbacterial proliferation.

    This is why you have to add an additive such as sodium metabisulfite(Na2S2O5), or sodium benzoate (Na+ + C6H5COO-). These additives are

    oxygen scavengers which stop bacterial proliferation.

    The package must then be sealed (in a bag or a coffer).

    Finally, the membrane must be stored in a place where temperatureexceeds 0C.

    30

    Membrane storage at end of season

  • 7/30/2019 H2O_Innovation_Maple_Membrane_Training_2011_ENG.pdf

    31/31

    31

    Question?