H1B 110 Bent Axis Variable Motor Data SheetH1B with Electric Proportional Control (De-energized =...
Transcript of H1B 110 Bent Axis Variable Motor Data SheetH1B with Electric Proportional Control (De-energized =...
For more than 40 years, Danfoss has been developingstate-of-the-art components and systems for mobilemachinery used in off-highway operations around theworld.
We have become a preferred supplier by offering thebest of what really matters: The hardware inside yourvehicle application.
H1 - our new generation of servo-controlledhydrostatic pumps and bent axis variable motors is noexception.
The H1 product is built around an advanced controland available in a wide range of displacements. It isdesigned for quality and reliability and offersexpanded functionality, greater total efficiency, andeasy installation.
All H1 control and sensor options are PLUS+1®
Compliant. PLUS+1® allows you to rapidly developand customize electronic machine control. It opensup the future by combining machine controls anddiagnostics in an integrated operating network.
Features
Designed for quality and reliability
• Proven and optimized 9 piston rotatinggroup
• Single piece housing• Electric components with IP67 & IP69K
rating
Installation and packaging benefits
• Optimized for shortest length• Standardized connector interface• Integrated loop flushing device• Radial or axial high pressure ports
Greater total efficiency
• Minimized losses• Improved at high flow conditions
Wide range of controls
• Electric Two-position Control• Electric Proportional Control• Hydraulic Two-position Control• Hydraulic Proportional Control• Pressure Compensator Override• Proportional Pressure Compensator
Override• Brake Pressure Defeat option• Common controls across the entire
motor family• PLUS+1® Compliant control and sensor
options
Expanded functionality
• Zero degree capability together with ahigh performance 32 degree maximumangle
• Enhanced control functions withproportional controls de-energized atminimum or maximum displacement
• Optional integrated speed sensor with‒ Dual redundant speed sensing‒ Direction indication‒ Temperature sensing‒ Wire fault detection
Comprehensive technical literature online at powersolutions.danfoss.com
Data Sheet
H1 Bent Axis Variable Motor Size 110 cm³
© Danfoss | October 2019 AI00000033en-US0205 | 1
Technical specifications
Weight SAE ISO 3019/1 48.8 kg [108 lb]
DIN ISO 3019/2 45.0 kg [99 lb]
Output speed rated Max. displacement 2900 min-1 (rpm)
Min. displacement (6°) 4800 min-1 (rpm)
0° displacement 5350 min-1 (rpm)
Max. output speed Max. displacement 3700 min-1 (rpm)
Min. displacement (6°) 5950 min-1 (rpm)
0° displacement 6500 min-1 (rpm)
System pressure Working 450 bar [6527 psi]
Maximum 480 bar [6960 psi]
Min. low loop 7.5 bar [109 psi]
Case pressure Rated 3 bar [44 psi]
Max. 5 bar [73 psi]
Min. 0.3 bar [4 psi]
Schematic
H1B with Electric Proportional Control (De-energized = max.displacement)
A
B
n
minmax C1
M4 M5 MB
L1
L2 N
P003426
MA
Dimensions
X
X
X
Y
Y
Y
View X
View X
View X
View Y
View Y
View Y
SAE ISO 3019/1 with Electric Proportional Control (de-energized = max. displacement)
DIN ISO 3019/2 with Electric Proportional Control (de-energized = min. displacement)
Cartridge with Electric Two-Position Control (de-energized = min. displacement)Pressure Compensator Override, Brake Pressure Defeat
316±2[12.44±0.09]
279±2[11±0.09]
174±2[6.85±0.09]
89[3.50]
85[3.35]
85[3.35]
89[3.50]
89[3.50]
89[3.50]
50[1.97]
50[1.97]
50[1.97]
50[1.97]
125[4.92]
125[4.92]
286[11.26]
50[1.97]
50[1.97]
200[7.87
190[7.48]
200
[7.8
7]
8x 8
0.8
[3.1
8]8x
70.
7[2
.78]
4x 20.6[0.81]
2x 21[0.83]
4x 1
7.5
[0.6
9]
12.45[0.49]
10.8[0.49]
175
[6.8
9]
Ø15
2.4
[6.0
0]Ø
160
[6.3
0]
Ø20
0[7
.874
]
197
[7.7
6]13
1[5
.15]
247
[9.7
3]
222
[8.7
4]
190
[7.4
8]
Servo PressureGauge Port “M4”0.5625-18UNF-2B 9/16 -18UNF-2B
Servo PressureGauge Port “M4”0.5625-18UNF-2B 9/16 -18UNF-2B
Split Flange Boss “A”+”B”DN 25 Typ I 40MPa Seriesper ISO 6162Thread: M12x1.7521.5 [0.85] full Thread Depth
Split Flange Boss “A”+”B”DN 25 Typ I 40MPa Seriesper ISO 6162Thread: M12x1.7521.5 [0.85] full Thread Depth
Split Flange Boss “A”+”B”DN 25 Typ I 40MPa Seriesper ISO 6162Thread: M12x1.7521.5 [0.85] full Thread Depth
System Pressure “A”+“B”Gauge Port ”MA”+ “MB”0.5625-18UNF-2B 9/16 -18UNF-2B
System Pressure “A”+“B”Gauge Port ”MA”+ “MB”1.0625-12UN-2B 1 1/16 -12UN-2B
Loop Flushing Valve
Loop Flushing Valve
Loop Flushing Valve
Min. AngleStop Adjustment
Speed Sensor Connector: Deutsch DTM04-6P
Solenoid Connector:Deutsch DT04-2P
Solenoid Connector:Deutsch DT04-2P
Solenoid Connector:Deutsch DT04-2P
System Pressure “A”+“B”Gauge Port ”MA”+ “MB”0.5625-18UNF-2B 9/16 -18UNF-2B
Loop Flushing Shuttle Spool
Loop Flushing Shuttle Spool
Loop Flushing Shuttle Spool
Min. AngleStop Adjustment
Min. AngleStop Adjustment
Servo PressureGauge Port “M5”0.5625-18UNF-2B 9/16 -18UNF-2B
Servo PressureGauge Port “M4”0.5625-18UNF-2B 9/16 -18UNF-2B
113[4.45]
131
[5.1
5]
P003406E
Speed Sensor Connector: Deutsch DTM04-6P
Speed Sensor Connector: Deutsch DTM04-6P
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to productsalready on order provided that such alterations can be made without changes being necessary in specifications already agreed.All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 | © Danfoss | October 2019 AI00000033en-US0205