H. A. Phillips & Co. | Pump Package Control Panels
Transcript of H. A. Phillips & Co. | Pump Package Control Panels
Pu
mp
Package
Co
ntro
lsP
HILLIP
SR
EFRIG
ERA
TION
H. A. Phillips & Co. | Pump Package Control Panels | PPCP-21E-01
VALVES • VESSELS • SYSTEMS • CONTROLS
770 Enterprise AvenueDeKalb, IL 60115
[email protected] 630-377-0050
VALVES • VESSELS • SYSTEMS • CONTROLS
2 630.377.0050 [email protected]
Main Design Features:
D ƵůƟ-Valve Control Ability:
The new standard control paneloffering can operate one or two makeup valve groups. The controllercan be setup to operate the valves inparallel or series. The valves can besolenoid + motorized expansion(Danfoss ICM valves), and/or solenoid+ HEV (Hand Expansion).
ZĞŵŽƚĞŽŵŵƵŶŝĐĂƟŽŶƐǁ ŝƚŚW> K ƚŚĞƌ
The new standard control panel has a built-in4-20mA output available to pass on the level %to a central PLC or other remote monitoringdevice.
D ŽĚďƵƐZ^ϰϴϱƐĞƌŝĂůĐŽŵŵƵŶŝĐĂƟŽŶƐĂƌĞƚŚĞƐƚĂŶĚĂƌĚ ďƵŝůƚ-in means of remoteĐŽŵŵƵŶŝĐĂƟŽŶƐĂŶĚŵŽŶŝƚŽƌŝŶŐĚĚŝƟŽŶĂůŚĂƌĚǁ ĂƌĞ;ŐĂƚĞǁ ĂLJĚĞǀ ŝĐĞŝŶĂƐĞƉĂƌĂƚĞƐŵĂůůƉĂĐŬĂŐĞĚƉŽůLJĐĂƌďŽŶĂƚĞĞŶĐůŽƐƵƌĞǁ ŝƚŚĂĐĐŽŵƉĂŶLJŝŶŐŝŶƐƚƌƵĐƟŽŶƐͿĂƌĞĂǀ ĂŝůĂďůĞĨŽƌpurchase to allow for a central PLC / SCADA to communicate with the controller viaethernet. Remote enable (run) and reset inputs are also included.
Built-ŝŶWƵŵƉD ŽŶŝƚŽƌŝŶŐWƌŽƚĞĐƟŽŶ ĂŶĚƵƚŽ ǁ ŝƚĐŚŝŶŐ
The new standard control panel monitors and protects up to (3) pumps. The panel monitors the beneathŝŶƉƵƚƐ /ĨƚŚĞĐŽŶƚƌŽůƐĂƌĞƐĞƚƵƉĂƐƐƵĐŚ ƚŚĞƐƚĂŶĚďLJƉƵŵƉǁ ŝůůďĞĂƵƚŽŵĂƟĐĂůůLJƐƚĂƌƚĞĚŝĨƚŚĞƉƌŝŵĂƌLJpump(s) fails.
WƵŵƉƌƵŶĐŽŶƚĂĐƚƐ;ĐŽŶĮ ƌŵĂƟŽŶŽĨƌƵŶͿ
Pump motor current (protects against too high or too low amps)
ŝī ĞƌĞŶƟĂůƉƌĞƐƐƵƌĞ;ĨŽƌĐĂǀ ŝƚĂƟŽŶĂǀ ŽŝĚĂŶĐĞ ƉƌŽƚĞĐƟŽŶͿ
Pump Bypass Solenoid and Transfer Solenoid:
The new standard control panel has built-in outputs available for a pump bypass solenoid (for pump minflow), always energized while pump(s) are running, and a transfer solenoid output that energizes if the liquid level gets too high (as set in controller parameters).
Built-in VFD Fixed Speed Control:
The new standard control panel can operate a VFD at a fixed speed (ramps up from min to max setpoints).
VALVES • VESSELS • SYSTEMS • CONTROLS
[email protected] 630.377.0050
Main Design Features Cont...
Door Mounted % Full LED Bar Graph, and User Interface Module (Remote Keypad/Display):
Pumps and Level Inputs Flexibility:
The controls can accommodate up to three (3) pumps. In a typical two (2) pump setup one pump is set torun while the other is set to standby. In a typical three (3) pump setup two of the pumps are running withone in standby.
dŚĞĐŽŶƚƌŽůƐĐĂŶƵƟůŝnjĞĂϰ-20mA level probe signal and/or float/single point switch digital inputs.
ĞƚĂŝůĞĚŝƐƉůĂLJ/ŶĨŽƌŵĂƟŽŶ
The new standard display (both the internally mounted controller and the remote door display) showĚĞƚĂŝůĞĚŝŶĨŽƌŵĂƟŽŶ ĂŶĚĂůůŽǁ ĨŽƌĞĂƐLJƵƐĞƌŝŶƚĞƌĨĂĐŝŶŐ&ŽƌĨƵůůŝŶĨŽƌŵĂƟŽŶƉůĞĂƐĞƌĞĨĞƌƚŽƚŚĞĂŶĨŽƐƐ“MCX Vessel Liquid Level Controller User Guide”.
Pu
mp
Pac
kage
Co
ntr
ols
PH
ILLI
PS
REF
RIG
ERA
TIO
N
H. A. Phillips & Co. | Pump Package Control Panels | PPCP-21E-01
dŚƌĞĞdLJƉŝĐĂůsĂƌŝĂƟŽŶƐǀ ĂŝůĂďůĞ;/ŶWĂŝŶƚĞĚ ƚĞĞůŽƌ ^Ϳ
CRNMany Products
Registered
ASME "R" Bureau Veritas ISO 9001: 2015EĂƟŽŶĂůŽĂƌĚASME "U"
RETA MemberIIAR Member
ĂƐĞŽŶƚƌŽůWĂŶĞůKƉƟŽŶ;ŶŽƉƵŵƉƉŽǁ ĞƌĐŽŵƉŽŶĞŶƚƐͿ
Painted steel enclosure (NEMA 4) grey or Stainless Steel enclosure(NEMA 4X). 24”H x 20”W x 8”D
120V AC/60HZ/1PH power feed required to panel (for special powerrequirements contact factory)
Wireway, field terminals, markers, etc. & Wiring diagram
UL & cUL labels, per UL-508A
dĞŵƉĞƌĂƚƵƌĞZĂƟŶŐϯϮΣ&- 104°F
KƉƟŽŶĂůƐŚŝƉ-ůŽŽƐĞĂůĂƌŵŚŽƌŶ ϭϭϯĚ;ͿΛ ϯ ϯŌ
WĂŶĞůǁ ŝƚŚd>WƵŵƉ ƚĂƌƚĞƌƐKƉƟŽŶ
Painted steel enclosure (NEMA 4) grey or Stainless Steelenclosure (NEMA 4X). Approximate enclosure size is 42”H x 30”Wx 10”D
460V AC/60HZ/3PH power feed required to panel (for specialpower requirements contact factory)
Door Mounted Eaton Main Disconnect device (bypassable andůŽĐŬĂďůĞŝŶƚŚĞŽī ƉŽƐŝƟŽŶͿ
Wireway, field terminals, markers, etc. & Wiring diagram
UL & cUL labels, per UL-508A
dĞŵƉĞƌĂƚƵƌĞZĂƟŶŐϯϮΣ&- 104°F
dǁ Ž;ϮͿĂŶĚdŚƌĞĞ;ϯͿƉƵŵƉǀ ĂƌŝĂƟŽŶƐĂǀ ĂŝůĂďůĞĨŽƌŵƵůƟƉůĞmotor power ranges:
(2) Pumps <10A, 1hp – 5hp
(3) Pumps <10A, 1hp – 5hp
(2) Pumps 10A – 30A, 7.5hp – 20hp
(3) Pumps 10A – 30A, 7.5hp – 20hp
(2) Pumps 30A – 50A, 25hp – 40hp
(3) Pumps 30A – 50A, 25hp – 40hp
KƉƟŽŶĂůƐŚŝƉ-ůŽŽƐĞĂůĂƌŵŚŽƌŶ ϭϭϯĚ;ͿΛ ϯ ϯŌ
WĂŶĞůǁ ŝƚŚs &KƉƟŽŶ
Please contact factory for requests for panels with VFD power components.