Guide to Access Cover Selectionemea.ejco.com/wcsstore/EUROPE/EJEuropeAssets... · 2015. 3. 3. ·...
Transcript of Guide to Access Cover Selectionemea.ejco.com/wcsstore/EUROPE/EJEuropeAssets... · 2015. 3. 3. ·...
ejco.com 057 91 23100
Guide to Access Cover Selection
de
Guide to Access Cover Selection
ejco.com 057 91 23100
Guide to Access Cover Selection
EJ have the most comprehensive range of manhole covers and drainage gratings on the market and we excel at serving our customers.
Our Sales personnel are always on hand to assist you, with excellent product knowledge, working with you to offer solutions tailored to your needs.
EJ products are manufactured in best in class facilities and we hold over 1,000 tons of stock at our Birr facility, ensuring you of a ready supply of product at all times. We can deliver to you anywhere in Ireland.
Our European foundry, accredited to ISO 9001, ISO 14001 and OHSAS 18001 management systems.
Daily deliveries nationwide from our Birr facility.
EJ are Ireland’s leading supplier of InfrastructureAccess solutions.
Guide to Access Cover Selection
ejco.com 057 91 23100
Load Classification and Product Markings in EN124
EN 124 divides Manhole Covers and Drainage Gratings into 6 classes as follows : A15, B125, C250, D400, E600 and F900.The classification denotes the test load expressed in kN. Please note EN124 is the minimum performance specification, of there is any doubt, a higher category cover and frame should be selected. Contact our Sales Team on 057 91 23100 for assistance on product selection.
GROUP 1
MINIMUM CLASS A15
GROUP 2
MINIMUM CLASS B125
GROUP 3
MINIMUM CLASS C250
GROUP 4
MINIMUM CLASS D400
GROUP 5
MINIMUM CLASS E600
GROUP 6
CLASS F900
Areas which can only be used by pedestrians and pedal cyclists.
Footways, pedestrian and comparable areas, car parks or car parking decks.
For gully tops ins-talled in the area of kerbside channels of roads which when measured from the kerb edge, extend a maximum of 0,5m into the carriageway and a maximum of 0,2m into the footway.
Carriageways of roads (including pe-destrian streets),hard shoulders and parking areas, for all types of road vehicles.
Areas imposing high wheel loads, e.g. docks, aircraftpavements.
Areas imposing particularly high wheel loads, e.g. aircraft pavements.
Group 1
Group 4Group 3 1 puorG2 puorG3 puorG2 puorG1 puorG
D400
0.2mmax
0.2mmax
0.5mmax
0.5mmax
052C052C 521B521B
A15
A15A15
1 Identification of manufacturer and production site
2 Reference of standard
3 Mark of third party certification body
4 Load class
In order for products to comply with EN124 and to be third party certified the following markings must appear on the products.
2
3
41
ejco.com 057 91 23100
Guide to Access Cover Selection
Specifications for manhole covers and gratings in Ireland’s infrastructure are determined by the National Roads Authority (NRA) and local authority requirements. Reference is made to the European standard EN124 as well as guideline documents such as the Highways Agency’s Design Manual for Roads and Bridges - Chamber Tops and Gully Tops for Road Drainage and Services: Installation and Maintenance HA104. This Advice Note sets out procedures and defines materials which will provide the best possible performance of manhole cover and gully grating installations in trunk roads and motorways. Its recommendations may be applied to other roads and traffic conditions, as appropriate.
General requirements in Ireland
NRA – Series NG500 section 507Safety precautions require that chamber covers have a minimum opening of 600x750mm where personnel may be required to enter completely. In carriageways, hard shoulders and verges chamber covers, frames and gratings should be a minimum of class D400. For further guidance see HA104.
HA104 – Advice NoteThe minimum classification for all chamber tops and gully tops installed in areas of trunk roads and motorways that are likely to be subject to traffic, either directly or indirectly, shall be D400 of BS EN 124.The installation of higher category covers and frames such as E600 should be considered in applications here the chamber is located in the wheel path of a motorway, trunk road or other road carrying over 1,500 commercial vehicles per day in each direction.
Such proposals should be discussed with the overseeing organisation. It should be noted that EN 124 is a minimum performance specification and if there is any doubt, a higher category cover and frame should be selected.
Directions for Management and control of roadworks Cork City Council.Directions for Management and control of roadworks Dublin City Council.
All manhole covers and frames shall be Class D400 to EN124, 150mm deep frame for roads and 100mm deep frame for footways and green areas. They shall be non rock design, have closed keyways, be manufactured from ductile iron or similar approved material and have 600*600mm or 600mm dia opening.Note: Dublin City Council require 600mm diameter opening in a square frame.
Greater Dublin Regional Code of Practice for Drainage works.This applies to Wicklow, Meath, Kildare, Fingal, Dun Laoghaire Rathdown County Councils and Dublin City Council.
All manhole covers and frames shall comply with EN124, Class D400 (or E600 for heavily trafficked main roads). Manhole covers with paving brick inserts are not accepted on the public drainage system.Specific details for covers shall be agreed with the Local Authority. Generally frames shall be square, with a circular insert of 600mm diameter and a minimum depth of 100mm. Heavily trafficked roads will require a 150mm deep frame.
Global expertise. Local understanding.
ejco.com 057 91 23100
Guide to Access Cover Selection
de
We create exceptional solutions.
From the site survey stage through to the design, installation and maintenance of your product, EJ are committed to working with you offering custom built solutions that meet the highest standards in the world.
Correct product selection
When selecting manhole covers and gully gratings factors such as public safety, durability and performance will dictate the type of product that should be specified.Our aim as market leader is to educate and impart knowledge to you the specifier/end user about the importance of correctly specifying products that will perform to your expectations.
EJ aims to remove the hassle from your product selection process.
Please consult with us to select a product from our wide range. Our expertise gained through in- house research and on -road testing allow us create the best access solutions available on the market.Features such as the elastomer cushioning support, the ribbing of the cover and the thickness of the frames enable our access covers and frames withstand the most intense traffic loads.
Quality and consistency are synonymous with EJ products which are endorsed with a 3rd Party certification mark, ensuring you receive independent assurance that our product meets the relevant standards for Manhole Covers and Gully Gratings.
“ For safety critical products such as manhole tops and gully tops, your decisions cannot be taken lightly. You are responsible for the whole life performance of an installation, which in turn will influence on-going public safety. When you specify something as important as this, you have only one chance to get it right”BSI Certification Scheme
ejco.com 057 91 23100
Guide to Access Cover Selection
Circular Covers - EN124 D400FeaturesHow to specify product
product code
reference clear opening (mm)
overall dimensions(mm)
height(mm)
MAESTROHinged ductile iron cover and frameSlam lock system- 3 flexible ductile bars secure the cover in placeDouble wall frame for increased rigidity and to take the most intense traffic related stressSafety blocking of the cover which prevents it from accidently closing when in the open positionContinuous polypro EPDM cushioning insert, fixed to the cover Anti - theft captive hinge facilityOdour sealed and water resistant
546112 01 MAESTRO PKSR Ø600 Ø850 100
BRIO
Hinged ductile iron cover and frameRetractable handle - facilitates the opening andclosing of the coverDouble wall frame for increased rigidity limiting damage from traffic stressesSafety blocking of the cover which prevents it from accidently closing when in the open positionNeoprene gasket to minimise noise
New Anti - theft captive hinge facility
Option: Available in Ø700 clear opening
532186 01
532189 01
532275
532278
BRIO ROUND PKSR
BRIO SQUARE PKSC
BRIO ROUND LKD PKSRL
BRIO SQUARE LKD PKSCL
Ø600
Ø600
Ø600
Ø600
Ø850 850 x 850
Ø850
850 x 850
100
100
100
100
TWINOHinged ductile iron cover and frameSlam lock systemSafety blocking of the cover which prevents it from accidently closing when in the open positionNeoprene gasket to minimise noiseOption: Locking bolt
538633 01
538685 01
TWINO ROUND SR
TWINO SQUARE SC
Ø600
Ø600
Ø850
850 x 850
100
100
OPTODrop in ductile iron cover and frameNeoprene gasket to minimise noise2 open keyways
526294 OPTO Ø600 Ø850 75
New
Added features
Artistic Cover design Customise any of our access covers with your own logo or Local Authority crest.
PKSR = Precaptive hinge, safety block , round frame PKSC = Precaptive hinge, safety block , square frame
ejco.com 057 91 23100
Guide to Access Cover Selection
SINCLAIR Double triangular coversNon rock covers by means of threepoint suspensionCovers loosely coupledClosed keyways
512467 SINCLAIR 750 x 600 910 x 760 100
NOROCDuctile iron single coverNon rock by means of V shaped seatingClosed keyways
532128 NOROC 600 x 600 850 x 850 100
SCORPION 100 or 150 HIGHDouble triangular coversNon rock covers by means of three point suspensionCovers loosely coupled Closed keywaysOption: Locking with a M16 boltRound openingSurface Water (SW) and Foul Water (FW) badging available
544787 01
710080
710081
710019
710020
SCORPION 675
SCORPION 100
SCORPION 100 ROUND OPE
SCORPION 150
SCORPION 150 ROUND OPE
675 x 675
600 x 600
Ø600
600 x 600
Ø600
840 x 840
760 x 760
760 x 760
780 x780
780 x780
100
100
100
150
150
PYTHON 100 or 150 HIGHDouble triangular coversNon rock covers by means of threepoint suspensionCovers loosely coupledClosed keywaysOption: Round openingSurface Water (SW) and Foul Water (FW)badging available
710011
710034
710035
710036
PYTHON 100 PYTHON 100 ROUND OPENING
PYTHON 150
PYTHON 150 ROUND OPENING
600 x 600
Ø600
600 x 600
Ø600
750 x750
750 X 750
750 x750
750 x750
100
100
150
150
Square Covers - EN124 D400
Square Covers - EN124 E600FeaturesHow to specify product
product code
reference clear opening (mm)
overall dimensions(mm)
height(mm)
SCORPION 150 E600Double triangular coversNon rock covers by means of threepoint suspensionCovers loosely coupledClosed keyways
Option: Locking with a M16 bolt
710013
710009
SCORPION
SCORPION 150 ROUND OPE
600 x 600
Ø600
830 x 830
780 x 780
150
150
Guide to Access Cover Selection
ejco.com 057 91 23100
Access Covers - EN124 B125FeaturesHow to specify product
product code
reference clear opening (mm)
overall dimensions(mm)
height(mm)
TIGERDuctile iron circular cover in a square frameBS closed keywaysOption: Locking with a M16 bolt
710052
710054
TIGER
TIGER LKD
Ø550
Ø550
670 x 670
670 x 670
60
60
QUATTRODuctile iron cover and frameSlide out operationClosed keywaysOption: Locking bolt
536146
528351
522068
522066
522065
QUATTRO 700
QUATTRO 600
QUATTRO 500
QUATTRO 400
QUATTRO 300
600 x 600
500 x 500
400 x 400
300 x 300
202 x 202
700 x 700
600 x 600
500 x 500
400 x 400
300 x 300
42
40
40
39
39
Waterworks CoversCHEETAH FH, SV, AV, M
EN124 D400Ductile iron cover and frameNon rock by means of three point suspensionOpen keywaysCan be badged FH, SV, AV, M or unbadged
544816 01
710351
544817 01
710330
CHEETAH FH
CHEETAH SV
CHEETAH AV
CHEETAH M
445 x 280
445 x 280
445 x 280
445 x 280
645 x 480
645 x 480
645 x 480
645 x 480
100
100
100
100
3823 FH, SV, ScV, Av, MBS5834 Grade A loadingDuctile iron cover and frameDouble triangular covers for non rock performanceOpen keywaysCan be badged FH, SV,ScV, AV, M
544918 01
544917 01
544921 01
544919 01
544920 01
3823 FH
3823 SV
3823 ScV
3823 AV
3823 M
380 x 230
380 x 230
380 x 230
380 x 230
380 x 230
500 x 350
500 x 350
500 x 350
500 x 350
500 x 350
125
125
125
125
125
LEOPARD FH, SV, AV, MEN124 B125Ductile iron cover and frameSingle drop in coverOpen keywaysCan be badged FH, SV, AV, M or unbadged
710300
710391
710340
710320
LEOPARD FH
LEOPARD SV
LEOPARD AV
LEOPARD M
445 x 275
445 x 275
445 x 275
445 x 275
580 x 410
580 x 410
580 x 410
580 x 410
65
65
65
65
SV GRADE ABS5834 Grade A loadingDuctile iron cover and frameDouble triangular covers for non rock performanceOpen keyways
544634 01 1616 SV 163 x 163 247 x 247 100
ejco.com 057 91 23100
Guide to Access Cover Selection
Drainage Gratings - EN124 D400
Drainage Gratings - EN124 C250LION 75
End hinged ductile iron grating and frameFlat, 3 sided frameOption: Locking with a M16 bolt
710112
710118
LION 75
LION 75 LKD
360 x 310
360 x 310
510 x 400
510 x 400
75
75
PUMAKerb side hinged ductile iron grating and frameDished, 4 sided frameOption: Locking with a M16 bolt
532883
532884
PUMA
PUMA LKD
390 x 316
390 x 316
544 x 470
544 x 470
100
100
FeaturesHow to specify product
product code
reference clear opening (mm)
overall dimensions(mm)
height(mm)
GD6060A T3Hinged ductile iron grating and frameAnti - theft captive hinge facility
532252 GD6060A T3 600 X 600 720 X 720 100
BUFFALO 100End hinged ductile iron grating and frameFlat, 3 sided frameOption: Locking , reversible hingeLocking with a M16 bolt
710190
710191
BUFFALO 100
BUFFALO 100 LKD
430 x 375
430 x 475
525 x 525
525 x 525
100
100
LION 100 End hinged ductile iron grating and frameFlat, 3 sided frameOption: Locking with a M16 bolt
710124
710125
LION 100
LION 100 LKD
360 x 310
360 x 310
510 x 400
510 x 400
100
100
ejco.com 057 91 23100
Guide to Access Cover Selection
de
ejco.com
Americas+1 800 874 4100
EMEAEurope, Middle East and Africa +33 344 08 28 00
Asia-Pacific+61 73216 5000
Registered trademarks
IrelandRoscrea RoadBirrCo Offalytel 057 91 23100fax 057 91 [email protected]
Guide to Access Cover Selection - February 2015
CAVANAGH®
NORINCO® TELECOM®
SELFLEVEL®
ERMATIC®
CHILDSAFETY®
DEFENSO®
DEFENSO®
NORGUSS®
CABLECOM® NORLONG®
MAXIMO® AQUERA®