GSM BTS3012A Hardware Structure ISSUE1.0.pdf

download GSM BTS3012A Hardware Structure ISSUE1.0.pdf

of 11

Transcript of GSM BTS3012A Hardware Structure ISSUE1.0.pdf

  • 7/28/2019 GSM BTS3012A Hardware Structure ISSUE1.0.pdf

    1/11

    1

    Huawei Confidential. All Rights Reserved

    OME201102 GSM BTS3012A

    Hardware Structure

    ISSUE 1.0

    2 Internal Use

    ObjectivesObjectives

    Upon completion of this course, you will be

    able to:

    Know the functions and features of

    BTS

    Master the BTS hardware structure

    Master the cable connection of BTS

  • 7/28/2019 GSM BTS3012A Hardware Structure ISSUE1.0.pdf

    2/11

    2

    3 Internal Use

    Chapter 1 Overview

    Chapter 2 Auxiliary Cabinet

    Chapter 3 Main Cabinet

    4 Internal Use

    LocationLocation

    MS: Mobile Station

    HLR: Home Location Register

    MSC: Mobile Switching Center

    VM: Voice Mailbox

    BTS: Base Transceiver Station

    AUC: Authentication Center

    VLR: Visitor Location Register

    OMC: Operation and Maintenance Center

    EIR: Equipment Identity Register

    BSC: Base Station Controller

    SMC: Short Message Center

    PSTN

    ISDN

    PSPDN

    Um Interface

    BTS

    BTS

    BTS

    BTS

    OMC

    HLR/AUC/EIR

    BSCMSC/VLR

    SMC/VM

    A Interface

    MAP MAP

    TUP,ISUP

    MS

    MS

    MS

  • 7/28/2019 GSM BTS3012A Hardware Structure ISSUE1.0.pdf

    3/11

  • 7/28/2019 GSM BTS3012A Hardware Structure ISSUE1.0.pdf

    4/11

    4

    7 Internal Use

    Hardware StructureHardware Structure

    DATA_BUS/CONTROL_BUS/TIMING_BUS

    TMU

    Transmission

    device

    PMU

    FH_BUS

    CDU

    PSU

    TRX

    TRX

    TRX

    Signal Processing UnitCommon Unit

    CDU

    CDU

    antenna

    antenna

    antenna

    Antenna Feeder Unit

    External

    control

    External

    alarm

    Opt. fiber

    XDSL

    E1

    8 Internal Use

    Cabinet and BoardsCabinet and Boards

    Boards in Cabinet:

    CDU: Combiner & Divider Unit

    TRX: Transceiver

    PMU: Power Monitoring Unit

    TMU: Timing/Transmission &

    Management Unit

    PSU: Power Supply Unit

    TDU: Time Distribution Unit

    TCU: Temperature Control Unit

    ABB: Abis By-pass Board

    TSU: Transmission Power

    Supply Unit

    EMUA: Environment Monitor

    Unit Analyzer

    Transmissiondevice

    Sub-rack

    T

    S

    U

    C

    D

    U

    C

    D

    U

    C

    D

    U

    C

    D

    U

    C

    D

    U

    C

    D

    U

    T

    R

    X

    T

    R

    X

    T

    R

    X

    T

    R

    X

    T

    R

    X

    T

    R

    X

    T

    R

    X

    T

    R

    X

    T

    R

    X

    T

    R

    X

    T

    R

    X

    T

    R

    X

    T

    C

    U

    P

    S

    U

    P

    S

    U

    P

    S

    U

    P

    S

    U

    P

    S

    U

    P

    M

    U

    P

    S

    U

    FAN

    FAN FAN

    FAN

    Switch Box

    CableInlet

    AC powerdistribution

    Sub-rack

    E1 lighteningProtectionsub-rack

    DC powerdistribution

    Sub-rack

    BatteryCabin

    CableInlet

    TM

    U

    ABB

    A

    BB

    Auxiliary CabinetAuxiliary Cabinet Main CabinetMain Cabinet

  • 7/28/2019 GSM BTS3012A Hardware Structure ISSUE1.0.pdf

    5/11

    5

    9 Internal Use

    Chapter 1 Overview

    Chapter 2 Auxiliary Cabinet

    Chapter 3 Main Cabinet

    10 Internal Use

    Auxiliary SystemAuxiliary System

    Um

    MS

    BTS3012A

    Auxiliary CabinetMain Cabinet BSC

    Abis

    Environment

    monitoring system

    Temperature

    adjustment system

    Power

    Distribution system

  • 7/28/2019 GSM BTS3012A Hardware Structure ISSUE1.0.pdf

    6/11

    6

    11 Internal Use

    I. 220V AC threeI. 220V AC three--phase distributionphase distribution

    Power Distribution SystemPower Distribution System

    A

    N

    N

    B

    C

    N

    32A

    5A

    32A

    5A

    A,N

    B,N

    L,N

    Contactor

    AC distribution Unit

    TCU

    PSU

    Arrester

    MCBEMI

    filter

    220V AC input

    +24V DC

    Input to the DC

    Distribution frame

    Socket 1

    Socket 2

    AC conditioner/heat

    exchanger

    A

    B

    C

    N

    Regulator

    12 Internal Use

    II. 220V AC singleII. 220V AC single--phase distributionphase distribution

    Power SupplyPower Supply

    L

    N

    N

    L

    L

    N

    32A

    5A

    32A

    5A

    L,N

    L,N

    Contactor

    AC distribution Unit

    TCU

    PSU

    Arrester

    MCBEMI

    filter

    220V AC input

    +24V DCN

    Socket 1

    Socket 2

    Input to DC

    Distribution frame

    AC conditioner/heat

    exchangerRegulator

    L,N

    L

  • 7/28/2019 GSM BTS3012A Hardware Structure ISSUE1.0.pdf

    7/11

    7

    13 Internal Use

    III. 110V AC threeIII. 110V AC three--phase distributionphase distribution

    Power SupplyPower Supply

    A

    N

    N

    B

    C

    N

    32A

    5A

    32A

    5A

    B,N

    C,N

    AC distribution Unit

    TCU

    PSU

    Arrester

    MCBEMI

    filter

    110V AC input

    +24V DC

    Input to the DC

    Distribution frame

    AC conditioner/heat

    exchanger

    A

    B

    C

    N

    Regulator

    Transformer

    Transformer

    A,N

    Contactor

    Socket 1

    Socket 2

    14 Internal Use

    +24vDC+24vDCdistributiondistribution

    Power SupplyPower Supply

    AC input lightning protection power distribution unit A1441Z

    PSU PSU PSU PMU

    +24V DC output

    DC distribution copper bar

    Output bus bar

    Input bus bar 220V AC input

  • 7/28/2019 GSM BTS3012A Hardware Structure ISSUE1.0.pdf

    8/11

    8

    15 Internal Use

    PSU ConfigurationPSU Configuration

    144 ~ 6 One PSU for

    backup

    1610 ~ 12

    157 ~ 9

    131 ~ 3220/110VAC

    notesBoards (PMU)Boards (PSU)Capacity (TRX)mode

    16 Internal Use

    TSU (optional)TSU (optional)

    The TSU works under 1+! backup mode. Normally the two TSUs

    output equalized current. When one TSU gets faulty, another TSU will

    supply power to the transmission equipment and report alarms.

    -

    +24VDC IN

    +

    -

    -48VDC IN+

    Transmission device

    TSUTSU

  • 7/28/2019 GSM BTS3012A Hardware Structure ISSUE1.0.pdf

    9/11

    9

    17 Internal Use

    PMU structurePMU structure

    PMUPMU

    AC/DC

    AC power supply

    Power monitoring

    unit PMUFan

    Fuse

    Load

    AC/DC AC/DC AC/DC

    Battery

    18 Internal Use

    FMUFMU

    Fan feeding

    Fan revolution speed control

    Alarm detection +24V power supply input interface

    Functions of FMUFunctions of FMU

  • 7/28/2019 GSM BTS3012A Hardware Structure ISSUE1.0.pdf

    10/11

    10

    19 Internal Use

    TCUTCU

    TCU real-time monitors the temperature

    in the cabinet. By controlling the power

    distribution of the cabinet, it can prevent

    the damage of over-high or over-low

    temperature to the equipment and

    components.

    TCU controls the 220V AC input from

    the external power supply, the +24V DC

    output of the storage batteries

    (excluding the power distribution of the

    air-conditioner) and the power-on/off

    commands for some boards according

    to the temperature of the cabinet.

    Functions of TCUFunctions of TCU

    Sensor

    PMU

    TCU

    TMU

    AC lightning

    protection board

    Storage battery

    TRX/CDU

    Voltage Stabilizer

    Air conditioner/heat

    exchangerMonitoring

    Subsystem

    Alarm

    signals

    Control

    signals

    Control

    signals

    Temperature Test

    Access test

    Water test

    Smoke test

    20 Internal Use

    Temperature Adjustment SystemTemperature Adjustment System

    The heat dissipation and heating under low temperature of

    outdoor BTS3012A are accomplished by temperature adjustment

    system. The temperature adjustment system has high reliability

    performance and reports alarms when faults occur. The

    temperature adjustment of BTS3012A is accomplished by the air-

    conditioner or the heat exchanger.

  • 7/28/2019 GSM BTS3012A Hardware Structure ISSUE1.0.pdf

    11/11

    11

    21 Internal Use

    Chapter 1 Overview

    Chapter 2 Auxiliary Cabinet

    Chapter 3 Main Cabinet

    Huawei Confidential. All Rights Reserved