grundfos BMS/ BMST/ BMSX · 14 BMS hp pump 15 Flowmeter (high-pressure raw water) 17 Flowmeter...
Transcript of grundfos BMS/ BMST/ BMSX · 14 BMS hp pump 15 Flowmeter (high-pressure raw water) 17 Flowmeter...
1
BMS/ BMST/ BMSXHigH pressure and reverse osmosis systems
grundfos INSTRUCTIONS
2 3
BMS hpA
1
3
4
5
7 8 9 10
211
12
6
FT
Pos. Description
1 Raw-water feed pump 2 Pressure gauge (raw water) 3 Filter 4 Low-pressure switch 5 Flowmeter 6 BMS hp pump 7 High-pressure switch 8 Pressure gauge (BMS hp discharge pressure) 9 Air vent 10 Pressure relief valve 11 Pressure gauge (fresh-water pump) 12 Fresh-water flush pump
4 5
L1 / UL2 / V L3 / WNPE
b
0/Off
1/On
BMS hp
OPTIONAL
CON
NECTIO
NFO
R PC-TOO
L
NC1
C1 NO
1SIG
NAL RELAY:
MAX: 250V/2A AC1
MIN
: 5V/10mA
NC2
C2 NO
2SIG
NAL RELAY:
MAX: 250V/2A AC1
MIN
: 5V/10mA
L3L2L1
SUPPLY:
SEE NAM
EPLATE:FO
R FURTH
ER DATA:
17: PT100 A18: PT100 A19: PT100 B20: PT100 B
STATUS LED
7: SENSO
R INPU
T8: +24V9: G
ND
0-10V0/4-20mA
1: DIG
ITAL INPU
T 210: D
IGITAL IN
PUT 3
11: DIG
ITAL INPU
T 412: AN
ALOG
OU
TPUT
13: GN
D14: SEN
SOR IN
PUT 2
15: +24V (2)16: G
ND
0-10V0/4-20mA
A: RS485 AY: RS485 G
ND
B: RS485 B
+
0 -
0/4 - 20mA
2: RUN
/STOP
3: GN
D4: SETPO
INT
5: +10V6: G
ND
PE
ALAR
M
PUM
P RU
NN
ING
STAR
T/ST
OP
SETP
OIN
T
L1 L2 L3
L2L1 L3 PE
ELCB
6 7
BMS hsA
7 8 9 10
2
1
3
4
5
11
12
Built-in
6
FT
Pos. Description
1 Raw-water feed pump 2 Pressure gauge (raw water) 3 Filter 4 Low-pressure switch 5 Flowmeter 6 BMS hs pump (with built-in non-return valve). 7 High-pressure switch 8 Pressure gauge (BMS hs discharge pressure) 9 Air vent 10 Pressure relief valve 11 Pressure gauge (fresh-water pump) 12 Fresh-water flush pump
8 9
BMS hsB
0/Off
1/On
+10V
ref
AI1+
AI1-
AI2+
AI2-
0V COM
-RL1
RL1
COM
-RL2
RL2
AO1
AI3
+24V
ref
DO
1
STO
-1
DI2
DI3
STO
-2
DI5
DI4
+24V
ref
1 2 3 4 5 6 1 2 3 487
0VDI1/
PTC
109 1 2 3 4 5 6 87 9
PX1
PX2
PX3
stat
us re
lay
Driv
e (N
/O)
Ala
rm re
lay
max
imum
spee
d (N
/O)
0-10
V
spee
d re
fere
nce
4-20
mA
spee
d re
fere
nce
4-20
mA
curr
ent i
mag
e
Mot
or P
TC*
Zero
spee
dS
afe
Torq
ue O
�/D
rive
enab
le in
put 1
Refe
renc
e se
lect
ion
Refe
renc
e se
lect
ion
Saf
e To
rque
O�/
Driv
e en
able
inpu
t 2Ru
n FW
D/S
top
Run
RE
V/S
top
L1 / UL2 / V L3 / WNPE
0.3 Nm
ALAR
M
SETPOINTSTART/STOP
SAfE TORqUE Off INPUT
M8 - 10 Nm M10 - 20 Nm M12 - 35 Nm M16 - 65 Nm
0-20 mA4-20 mA
0-10 V+/-10 V
PTC
7.06 to 7.14
8.09 8.245.70 & 8.21
QS
OptionalRFI �lter
QS
OptionalRFI �lter
10 11
BMSTA
2
3
4
5
9 10 11
1213
14
7
15
8
6.1
6
FT
FT
1 16
Pos. Description
1 Raw-water feed pump 2 Pressure gauge (raw water) 3 Filter 4 Low-pressure switch 5 Flowmeter 6 BMT pump 6.1 BMS hs pump 7 Pressure gauge (BMST discharge pressure) 8 Flowmeter 9 Air vent 10 High-pressure switch 11 Pressure relief valve 12 Membrane filter 13 Permeate 14 Pressure gauge (high-pressure concentrate) 15 Pressure gauge (fresh-water pump) 16 Fresh-water flush pump
12 13
C
0/Off
1/On
BMST
+10V
ref
AI1+
AI1-
AI2+
AI2-
0V COM
-RL1
RL1
COM
-RL2
RL2
AO1
AI3
+24V
ref
DO
1
STO
-1
DI2
DI3
STO
-2
DI5
DI4
+24V
ref
1 2 3 4 5 6 1 2 3 487
0VDI1/
PTC
109 1 2 3 4 5 6 87 9
PX1
PX2
PX3
stat
us re
lay
Driv
e (N
/O)
Ala
rm re
lay
max
imum
spee
d (N
/O)
0-10
V
spee
d re
fere
nce
4-20
mA
spee
d re
fere
nce
4-20
mA
curr
ent i
mag
e
Mot
or P
TC*
Zero
spee
dS
afe
Torq
ue O
�/D
rive
enab
le in
put 1
Refe
renc
e se
lect
ion
Refe
renc
e se
lect
ion
Saf
e To
rque
O�/
Driv
e en
able
inpu
t 2Ru
n FW
D/S
top
Run
RE
V/S
top
L1 / UL2 / V L3 / WNPE
0.3 Nm
ALAR
M
SETPOINTSTART/STOP
SAfE TORqUE Off INPUT
M8 - 10 Nm M10 - 20 Nm M12 - 35 Nm M16 - 65 Nm
0-20 mA4-20 mA
0-10 V+/-10 V
PTC
7.06 to 7.14
8.09 8.245.70 & 8.21
QS
OptionalRFI �lter
QS
OptionalRFI �lter
14 15
BMSXA
2
3
4
16
8
7
9 10 11
1819
13
21
22
24
20
175
25
26
27
Built-in
12 15
23
14
6
FT
FT
FT
FT
1
Pos. Description
1 Raw-water feed pump 2 Filter 3 Low-pressure switch 4 Flowmeter 5 Pressure gauge (raw water) 6 BMS hs pump (with built-in non-return valve). 7 Non-return valve 8 Pressure gauge (BMS hs discharge pressure) 9 Air vent 10 High-pressure switch 11 Pressure relief valve 12 Pressure gauge (BMS hp inlet pressure) 13 Pressure gauge (BMS hp discharge pressure) 14 BMS hp pump 15 Flowmeter (high-pressure raw water) 16 Pressure gauge (low-pressure raw water) 17 Flowmeter (low-pressure raw water) 18 Membrane filter 19 Permeate 20 Cleaning flush valve. 21 Pressure gauge (high-pressure concentrate) 22 Pressure gauge (low-pressure concentrate) 23 Pressure exchanger 24 Concentrate valve 25 Pressure gauge (fresh-water pump) 26 Fresh-water flush pump 27 Flowmeter
16 17
1
3
4
10
17
26
27
Built-in
2
16
8
7
9 11
1819
13
21
22
24
5
25
12 15
14
6
FT
FT
FT
FT
20
Pos. Description
1 Raw-water feed pump 4 Flowmeter 6 BMS hs pump (with built-in non-return valve). 10 High-pressure switch 14 BMS hp pump 15 Flowmeter (high-pressure raw water) 17 Flowmeter (low-pressure raw water) 26 Fresh-water flush pump 27 Flowmeter
Page 6
Page 8
START/STOP
SETPOINT
SETPOINT
START/STOP
BMSXB
0/Off
1/On
CBMSX
18 19
D
1 min.
MDX commissioning software
20
GRUNDfOS Holding A/SPoul Due Jensens Vej 7DK-8850 Bjerringbro Tlf.: +45-87 50 14 00
The
nam
e G
rund
fos,
the
Gru
ndfo
s log
o, a
nd th
e pa
yoff
be th
ink
inno
vate
are
regi
ster
ed tr
adem
arks
ow
ned
by G
rund
fos H
oldi
ng A
/S o
r Gru
ndfo
s A/S
, Den
mar
k. Al
l rig
hts r
eser
ved
wor
ldw
ide.
98737800 1014
ECM: 1140908