GRUNDFOS DATA BOOKLET
Grundfos Basic
50 Hz
2
Contents
JPBasicPerformance range Page 3General data Page 4Applications Page 4Constructional features Page 4Material specification Page 5Technical data Page 5Curve conditions Page 5
JPBasic PTGeneral data Page 10Applications Page 10Constructional features Page 10Material specification Page 10Technical data Page 11
JPBasic PSGeneral data Page 12
JPBasic PCGeneral data Page 13Applications Page 13Operation Page 13Technical data Page 15
JDBasicGeneral data Page 16Applications Page 16Constructional features Page 16Material specification Page 16Technical data Page 17Instructions for conversion Page 18
CHBasicPerformance range Page 19General data Page 20Applications Page 20Constructional features Page 20Material specification Page 20Technical data Page 21Curve conditions Page 21
CHBasic PTGeneral data Page 24Applications Page 24Constructional features Page 24Material specification Page 24Technical data Page 25Curve conditions Page 25
CHBasic PSGeneral data Page 26Applications Page 26Constructional features Page 26Material specification Page 26Technical data Page 27Curve conditions Page 27
CHBasic PCGeneral data Page 28Applications Page 28Operation Page 28Constructional features Page 28Material specification Page 29Technical data Page 30Curve conditions Page 30
NSBasicPerformance range Page 31General data Page 32NSBasic single impeller pumps Page 32Applications Page 32Constructional features Page 32Material specification Page 32Technical data Page 33NSBasic twin impeller pumps Page 35Applications Page 35Constructional features Page 35Material specification Page 35Technical data Page 36
KPBasicPerformance range Page 39General data Page 40Applications Page 40Constructional features Page 40Technical data Page 41Curve conditions Page 41
PFBasicPerformance range Page 44General data Page 45Applications Page 45Constructional features Page 45Material specification Page 45Technical data Page 46
PFPBasicGeneral data Page 47Applications Page 47Constructional features Page 47Materials Page 47Technical data Page 48
3
JPBasic JPBasic
Performance range
TM0
2 89
36 1
8040 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
60
65
H[m]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 Q [l/s]
0
100
200
300
400
500
600
p[kPa]
JPBasic50 Hz
10
2
3
4
5
7
9
4
JPBasic General data
JPBasic 2, JPBasic 3, JPBasic 4
ApplicationsSelf-priming centrifugal pump with excellent suction capacity even when there are air bubbles and small sandy impurities in the water.
Used especially for supplying water to domestic systems. Ideal for use in small-scale agriculture and gardening, limited industrial services and wherever self-priming operation is necessary.
Constructional featuresPump
Cast iron pump body and motor support in cast iron treated against corrosion also on the inner surface. Technopolymer impeller, diffuser venturi tube and sand tube. Stainless steel pressure disc. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension.
Motor
Asynchronous motor cooled with external fan. Rotor mounted on greased sealed-for-life ball bearings, selected to ensure silent running and a long life.
Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for protection in the three-phase version. Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz
3 x 220-240/380-415 V, 50 Hz.
JPBasic 9, JPBasic 10
JPBasic 5, JPBasic 7
Gr7
90
3
Gr7
921
Gr7
917
5
JPBasic Technical data
Material specification
Technical dataOperating range: From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth: 8 metres
Maximum operating pressure: JPBasic 2, JPBasic 3, JPBasic 4: 6 bar (600 kPa) JPBasic 5, JPBasic 7, JPBasic 9, JPBasic 10: 7.5 bar (750 kPa)
Installation: Fixed in a horizontal position
Special executions on request: Other voltages and/or frequencies.
Curve conditionsThe performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
Pos. Description Material
1 Pump body Cast iron EN-GJL-200
3 Support Cast iron EN-GJL-200
4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2
7 Shaft AISI 303 stainless steel X 10 Cr NiS 18 9 *
8Venturi tube and nozzle
Noryl GFN 2
16 Mechanical seal Carbon/Ceramic
28 O-Ring gasket NBR
* JPBasic 1, JPBasic 2, JPBasic 4: X 12 Cr S 13
TM0
2 84
59 0
204
8 1 6 28 3
16 74
6
Technical data JPBasic
JPBasic 2
JPBasic 3
TM0
2 84
44 0
204
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
JPBasic 21 x 220-240 0.72 0.44 0.6 3.12 12.5 450
3 x 220-240/380-415 0.67 0.44 0.6 2.1/1.2 - -
C
H
GB
I
AA1
DNM
E F
H3
DN
A
TM0
2 9
023
130
40.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [m³/h]
0
5
10
15
20
25
30
35
40
[m]H
0
80
160
240
320
400[kPa]
P
0
20
40
60
80
100
120
[ft]H
Q [l/s]
0 10 20 30 40 Q [l/min]
0 2 4 6 8 10 Q [IMP GPM]
0 2 4 6 8 10 12 Q [US GPM]
0.0 0.2 0.4 0.6
2345
67
8
Pump type
Dimensions [mm]Packing dimensions
[mm] Vol
[m3]Weight
[kg]A A1 B C E F G H H3 I DNA DNM L/A L/B L/H
JPBasic 2 395 390 178 108 192 14 111 200 144 9 Rp 1 Rp 1 470 240 240 0.027 10.9
TM0
2 84
44 0
204
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
JPBasic 31 x 220-240 0.85 0.6 0.8 3.8 12.5 450
3 x 220-240/380-415 0.86 0.6 0.8 2.8/1.6 - -
C
H
GB
I
AA1
DNM
E F
H3
DN
A
TM0
2 9
024
130
40.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [m³/h]
0
5
10
15
20
25
30
35
40
45[m]H
0
80
160
240
320
400
[kPa]P
0
20
40
60
80
100
120
140
[ft]H
Q [l/s]
0 10 20 30 40 50 Q [l/min]
0 2 4 6 8 10 Q [IMP GPM]
0 2 4 6 8 10 12 14 Q [US GPM]
0.0 0.2 0.4 0.6 0.8 Q [l/s]
87
6 5 4 32
Pump type
Dimensions [mm]Packing dimensions
[mm] Vol
[m3]Weight
[kg]A A1 B C E F G H H3 I DNA DNM L/A L/B L/H
JPBasic 3 395 390 178 108 192 14 111 200 144 9 Rp 1 Rp 1 470 240 240 0.027 11
7
Technical data JPBasic
JPBasic 4
JPBasic 9
TM0
2 84
44 0
204
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
JPBasic 41 x 220-240 1.13 0.75 1 5.1 16 450
3 x 220-240/380-415 1.04 0.75 1 3.3/1.9 - -
C
H
GB
I
AA1
DNM
E F
H3
DN
A
TM0
2 9
025
130
40.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50[m]H
0
100
200
300
400
[kPa]P
0
20
40
60
80
100
120
140
160[ft]H
0 10 20 30 40 50 Q [l/min]
0 2 4 6 8 10 Q [IMP GPM]
0 2 4 6 8 10 12 14 Q [US GPM]
0.0 0.2 0.4 0.6 0.8 Q [l/s]
8 7
6 5 4 3 2
Pump type
Dimensions [mm]Packing dimensions
[mm] Vol
[m3]Weight
[kg]A A1 B C E F G H H3 I DNA DNM L/A L/B L/H
JPBasic 4 414 409 178 108 197 14 111 213 144 9 Rp 1 Rp 1 470 240 240 0.027 16.2
TM0
2 84
64
020
4
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
JPBasic 91 x 220-240 2 1.5 2 9 31.5 450
3 x 220-240/380-415
2 1.5 2 6.8/3.9 - -
AC
E F
H1
DN
A
BG
Iø
H
TM0
2 9
028
130
40 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
0
5
10
15
20
25
30
35
40
[m]H
0
100
200
300
400[kPa]
P
0
20
40
60
80
100
120
[ft]H
0 20 40 60 80 100 120 140 160 180Q [l/min]
0 4 8 12 16 20 24 28 32 36 40 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM]
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [l/s]
87 6 5 4
3 2 1
Pump type
Dimensions [mm]Packing dimensions
[mm] Vol
[m3]Weight
[kg]A B C E F G I ø H H1 DNA DNM L/A L/B L/H
JPBasic 9 521 214 151 282 20 160 11 227 175 Rp 1 ½ Rp 1 ¼ 612 248 279 0.042 27
8
Technical data JPBasic
JPBasic 10
JPBasic 5
TM0
2 84
64
020
4
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
JPBasic 101 x 220-240 2.7 2.2 3 12 40 450
3 x 220-240/380-415
2.7 2.2 3 8.5/4.9 - -
C
H
GB
I
AA1
DNM
E F
H3DN
A
TM0
2 9
029
130
40 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50[m]H
0
100
200
300
400
[kPa]P
0
20
40
60
80
100
120
140
160[ft]H
0 20 40 60 80 100 120 140 160 180Q [l/min]
0 4 8 12 16 20 24 28 32 36 40 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM]
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [l/s]
8
76
5 43 2 1
Pump type
Dimensions [mm]Packing dimensions
[mm] Vol
[m3]Weight
[kg]A B C E F G I Ø H H1 DNA DNM L/A L/B L/H
JPBasic 10 595 214 151 282 20 160 11 235 175 Rp 1 ½ Rp 1 ¼ 657 248 279 0.045 31.5
TM0
2 84
62
020
4
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
JPBasic 51 x 220-240 1.6 1.1 1.5 7.2 31.5 450
3 x 220-240/380-415
1.6 1.1 1.5 5.2/3.0 - -
G
B
Iø
E
AC
DNM
H1D
NE
HD
NA
Z
HH
1
XA
V
H2
TM0
2 9
026
130
40.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [m³/h]
0
10
20
30
40
50
60
[m]H
0
100
200
300
400
500
600
[kPa]P
0
40
80
120
160
200[ft]H
0 10 20 30 40 50 60 70 Q [l/min]
0 2 4 6 8 10 12 14 16 Q [IMP GPM]
0 2 4 6 8 10 12 14 16 18 20 Q [US GPM]
0.0 0.2 0.4 0.6 0.8 1.0 1.2 Q [l/s]
87
6
5 4
32
1
Pump type
Dimensions [mm]Packing dimensions
[mm] Vol
[m3]Weight
[kg]A B C E F G I ø H H1 DNA DNM L/A L/B L/H
JPBasic 5 558 210 221 350 20 145 11 255 158 Rp 1 ¼ Rp 1 612 248 279 0.045 31
9
Technical data JPBasic
JPBasic 7
TM0
2 84
62
020
4
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
JPBasic 71 x 220-240 2.2 1.85 2.5 10 40 450
3 x 220-240/380-415
2.2 1.85 2.5 6.9/4.0 - -
G
B
Iø
E
AC
DNM
H1D
NE
HD
NA
Z
HH
1
XA
V
H2
TM0
2 9
027
130
40 1 2 3 4 5 6 7 Q [m³/h]
0
10
20
30
40
50
60
[m]H
0
100
200
300
400
500
600
[kPa]P
0
40
80
120
160
200[ft]H
0 20 40 60 80 100 120 Q [l/min]
0 4 8 12 16 20 24 28 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 Q [US GPM]
0.0 0.4 0.8 1.2 1.6 2.0 Q [l/s]
8
76
5 4
3 2
1
Pump type
Dimensions [mm]Packing dimensions
[mm] Vol
[m3]Weight
[kg]A B C E F G I ø H H1 DNA DNM L/A L/B L/H
JPBasic 7 632 210 221 350 20 145 11 255 158 Rp 1 ¼ Rp 1 657 248 279 0.045 35
10
General dataJPBasic PT
JPBasic PT
ApplicationsAutomatic water lifting and pressure boosting sets, particularly suitable for domestic use, small installa-tions for civil, industrial and agricultural use, washing systems and hobbies.
The characteristics of the JPBasic-pumps are that they are self-priming electric pumps which can operate even when there is air, gas and small quantities of sand in the water.
The set is composed of a diaphragm tank with capacity 19 litres, pressure switch for automatic operation, pres-sure gauge, JPBasic electric pump complete with power cable and plug, kit for coupling the pump and the tank, all assembled and ready for installation.
Note: Vertical 8 litres or 18 litres tanks are used in some markets.
Constructional featuresPump
Cast iron pump body and motor support.
Technopolymer impeller, diffuser, Venturi tube and sand guard.
Stainless steel pressure discs.
Carbon/ceramic mechanical seal.
Motor
Induction motor, closed and cooled with external venti-lation. Rotor mounted on oversized greased sealed-for-life ball bearings, to ensure silent running and a long life.
Built-in thermal and current overload protection and a capacitor permanently in circuit.
Manufactured according to standard EN 60335-2-41.
Motor protection: IP 44 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz.
Tank
Horizontal type, capacity 19 litres, with butyl diaphragm, complete with feet on the bottom and brackets for fixing the pump on top.
Material specification
TM0
2 9
06
0 1
704G
ener
al d
ata
TM0
2 84
59 3
204
Pos. Description Material
1 Pump body Cast iron (EN-GJL-200)
3 Support Cast iron (EN-GJL-200)
4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2
7 Shaft Stainless steel AISI 416 X12 CrS 13
8 Venturi tupe and nozzle Noryl GFN 2
16 Mechanical seal Carbon/Ceramic
28 O-Ring gasket NBR
Components in contact with the liquid.
8 1 6 28 3
16 74
11
JPBasic PT Technical data
Technical dataOperating range: Up to 3.6 m3/h with head up to 51 metres.
Liquid quality requirements: Clean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water.
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum operating pressure: 6 bar (600 kPa)
Installation: Fixed in a horizontal position.
JPBasic PTTM
02
90
68
170
4
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P1
[hp]
In
[A]
Capacitor
[µF] [Vc]
JPBasic 2 PT 1 x 220-240 0.72 0.44 3.12 12.5 450
JPBasic 3 PT 1 x 220-240 0.85 0.6 3.8 12.5 450
JPBasic 4 PT 1 x 220-240 1.13 0.75 5.1 16 450
D
H1
H
BA
L
A1
TM0
2 89
40 1
704
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50[m]H
0
100
200
300
400
[kPa]P
0
20
40
60
80
100
120
140
160[ft]H
0 10 20 30 40 50 Q [l/min]
0 2 4 6 8 10 Q [IMP GPM]
0 2 4 6 8 10 12 14 Q [US GPM]
0.0 0.2 0.4 0.6 0.8 Q [l/s]
JPBasic 2
JPBasic 3
JPBasic 4
Pump typeDimensions [mm]
DNA DNMPacking dimensions [mm] Vol
[m3]Weight
[kg]L/A L/B L/HA A1 B D H H1 L
JPBasic 2 PT 550 390 270 282 290 232 332 Rp 1 Rp 1 576 366 554 0.107 16.1
JPBasic 3 PT 550 390 270 282 290 232 332 Rp 1 Rp 1 576 366 554 0.107 16.2
JPBasic 4 PT 550 409 270 282 290 232 332 Rp 1 Rp 1 576 366 554 0.107 21.4
12
JPBasic PS General data
JPBasic PSAuto pressure units
Single-phase version: Self-priming centrifugal pump equipped with pressure gauge, pressure switch (PS), power supply cable with plug and three-way brass connector for connecting to a tank.
JPBasic-PS
Gr7
90
8
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2Max.[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
JPBasic 2 PS 1 x 220-240 0.72 0.44 0.6 3.12 12.5 450
JPBasic 3 PS 1 x 220-240 0.85 0.6 0.8 3.8 12.5 450
JPBasic 4 PS 1 x 220-240 1.13 0.75 1.0 5.1 16 450
JPBasic 5 PS 1 x 220-240 1.6 1.1 1.5 7.2 31.5 450
Pump typeDimensions [mm]
DNA DNMPacking dimensions
[mm]Vol
[m3]Weight
[kg]L/A L/B L/HA A1 B C D E F G Iø H H1 H2 H3 I
JPBasic 2 PS 395 390 282 108 196 192 14 111 - 232 199 200 144 9 Rp 1 Rp 1 486 366 232 0.041 11.9
JPBasic 3 PS 395 390 282 108 196 192 14 111 - 232 199 200 144 9 Rp 1 Rp 1 486 366 232 0.041 12.1
JPBasic 4 PS 414 390 282 108 196 192 14 111 - 232 199 - 144 9 Rp 1 Rp 1 486 366 232 0.041 13.9
JPBasic 5 PS 563 556 217 160 109 329 15 145 11 312 279 221 159 - Rp 1 ¼ Rp 1 600 236 267 0.038 31.5
13
JPBasic PC General data
JPBasic PCSelf-priming centrifugal pump equipped with presscon-trol (PC) and power supply cable.
ApplicationsAutomatic water lifting sets, particulary suitable for domestic use, small installations for civil, industrial and agricultural use, washing systems and hobbies. These are characterised by the use of JPBasic PC self-priming centrifugal pumps which can operate even when there is air, gas and small quantities of sand in the water. They are indispensable for use in artesian wells and whereever suction difficulties arise.
OperationThe pump is equipped with a Presscontrol (PC) which controls, manages and commands it, regulating its oper-ation, limiting the number of starts and guaranteeing maximum pressure stability inside the hydraulic circuit in which it is installed.
The automatic devices is the result of a series of studies conducted to optimise the efficiency of the system while preserving the structural features and sturdiness of existent devices.
Automatic sets differ from the traditional systems equipped with a pressure switch based on pump starting and stopping as they avoid sudden variations and drops in pressure. They are basically equipped with a double control device, as built-in electrical circuit gathers the data regarding pressure and water flow in the system and processes them to allow the pump to operate under optimum performance conditions.
The automatic device is supplied pre-installed on the pump, requires no type of regulation and considerably reduces overall dimensions by totally eliminating the bulky tanks used traditional installations.
Gr7
90
7
14
JPBasic PC General data
Optimised management of the hydraulic installation and its components
1. Enables the system to operate only when there is wa-ter present; if, for any reason, no water reaches the system, it blocks the pump, so that it does not oper-ate while dry. In this case the ALARM LED lights up.
2. Maintains pump operation when the appliances are opened by one or more users, in order to prevent sud-den changes in pressure. When an appliance is opened the depression created in the system acts on the membrane which gradually releases a spring. The sensors detect the movement, send a signal to the electronic unit which enables pump start-up.
3. Automatically stops the pump when the users stop drawing water. When the appliances are closed, un-der the effect of the rise in pressure within the hy-draulic system, the membrane totally compresses the spring. This new situation is analysed by the sensors which send the unit a signal to stop the pump. The stop is timed in order to prevent the pump from be-ing subjected to repeated starts caused by users opening and closing the appliances within a few sec-onds of each other. Furthermore, if boilers are sup-plied, the continuous delivery of hot water is guaranteed by timing the stops.
4. Instant pump start when one of the appliances is opened even with a minimum amount of water drawn.
5. In the event of leaks in the system (drips or small trickles) the device limits the number of cycles, pro-longing pump running time by about 10 seconds.
6. It eliminates water hammering by means of a spe-cific shock absorber which absorbs the effect.
7. Manual reset in the event of a breakdown in the hy-draulic circuit or of overload protector intervention; in this case, after eliminating the cause, press the "RESET" button positioned on the terminal board cover for a few seconds until the "ALARM" LED switches off.
8. In the event of a power cut, automatic reset as soon as the power is restored.
9. The system is self-protected against overheating. When there is an excess in temperature inside the motor windings, this operation is carried out auto-matically. It is also restored automatically once the temperature has dropped below the level which guarantees operation without damage to the system.
Constructional features of the pump
JPBasic 3 PC, JPBasic 4 PC: Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer impeller, diffuser and Venturi tube. Stainless steel pres-sure discs and rotor shaft. Carbon/ceramic mechanical seal.
Constructional features of the motor
Induction motor, closed and cooled with external venti-lation. Rotor mounted on greased sealed-for-life ball bearings. Built-in thermal and current oyerload protec-tion and a capacitor permanently in circuit. Manufactured according to standard EN 60335-2-41.
Motor protection: IP 44 Insulation class: F.
All the pumps are supplied with 0.75 metres of power cable type H05 RN-F with plug.
Constructional features of the automatic control
The automatic device which regulates the pump opera-tion is basically formed of the following components:
FLOW SWITCH SET: this comprises a 4-way metal union with two housings for the delivery and pressure sensors. Both their seat and the sensor capsule are structured so that no pre-calibration is required.
SPRING EXPANSION TANK: manufactured in pressed and flanged stainless steel, this has been designed to ensure maximum reliability and sturdiness with minimum overall dimensions. Inside it houses a spring which oper-ates as a pressure switch.
ELECTRONIC CARD: this is composed of a printed circuit which receives signals from the sensors and manages the automatic device as indicated in the paragraph regarding operation. The commands plate with the two LEDs, green = ON, red = Alarm and the Reset button for resetting the pump is positioned on the terminal board cover.
CHECK DEVICE: all automatic sets are equipped with a check valve which has been selected to ensure maximum long lasting reliability. In order to prevent operational faults in the system it is essential that the position of the valve is not changed during assembly.
The automatic control is supplied pre-assembled with all the accessories.
15
JPBasic PC Technical data
Technical dataOperating range: From 0.3 to 3.6 m3/h with head up to 51 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum operating pressure: 6 bar (600 kPa)
Installation: Fixed in a horizontal position.
JPBasic PC
TM0
2 9
06
7 17
04
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
JPBasic 2 PC 1 x 220-240 0.72 0.44 0.6 3.12 12.5 450
JPBasic 3 PC 1 x 220-240 0.85 0.60 0.8 3.4 12.5 450
JPBasic 4 PC 1 x 220-240 1.13 0.75 1.0 4.7 16 450
B
G
I ø
CDNM
F
A
E
H DN
A
H3
TM0
2 89
40 1
704
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50[m]H
0
100
200
300
400
[kPa]P
0
20
40
60
80
100
120
140
160[ft]H
0 10 20 30 40 50 Q [l/min]
0 2 4 6 8 10 Q [IMP GPM]
0 2 4 6 8 10 12 14 Q [US GPM]
0.0 0.2 0.4 0.6 0.8 Q [l/s]
JPBasic 2
JPBasic 3
JPBasic 4
Pump typeDimensions [mm]
DNA DNMPacking dimensions
[mm] Vol
[m3]Weight
[kg]L/A L/B L/HA B C E F G I ø H H3
JPBasic 2 PC 395 212 108 192 14 111 9 375.5 144 Rp 1 Rp 1 524 248 309 0.04 14
JPBasic 3 PC 395 212 108 192 14 111 9 375.5 144 Rp 1 Rp 1 524 248 309 0.04 16
JPBasic 4 PC 414 212 108 197 14 111 9 375.5 144 Rp 1 Rp 1 524 248 309 0.04 16
16
General dataJDBasic
JDBasic 2, JDBasic 4
ApplicationsSelf-priming centrifugal pump for suction up to 27 metres, reached by means of an ejector to be inserted in wells with a diameter of 4" or over. For use in supplying water to farmhouses and in small-scale agriculture.
Constructional features Pump
Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer impeller, diffuser and Venturi tupe and brass nozzle. Stainless steel pressure disc. Carbon/ceramic mechan-ical seal mounted on stainless steel rotor shaft exten-sion.
Ejector: Cast iron body with anti-corrosive treatment also on the inner surface. Technopolymer Venturi tube and brass nozzle. The ejector is available in 3 models (E20 - E25 - E30) to be chosen according to performance requirements. (see tables on pages 17 and 18).
Material specification
JDBasic 5, JDBasic 7
Motor
Asynchronous motor, closed and cooled with external ventilation.
Rotor mounted on greased sealed-for-life ball bearings, selected to ensure silent running and a long life.
Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version.
For the protection of the three-phase motor it is advis-able to use a suitable overload protection complying with the regulations in force.
Manufactured according to standard EN 60335-2-41.
Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz
3 x 220-240/380-415 V, 50 Hz.
Gr7
899
Gen
eral
dat
a
Pos. Description Material
1 Pump body Cast iron EN-GJL-200
2 Ejector body Cast iron EN-GJL-200
3 Support Cast iron EN-GJL-200
4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2
7 Shaft with rotor
(JDBasic 2-4) Stainless steel AISI 416 X 12 Cr S 13
(JDBasic 5-7) AISI 303 X10 Cr NiS 18 9
8 Venturi Noryl GFN 2
9 Nozzle Brass
16 Mechanical seal Carbon/Ceramic
28 O-ring gasket NBR
TM0
0 9
974
10
97
TM0
2 84
56 0
204
8
2
9
1 6 28 3
16 4 7
17
JDBasic Technical data
Technical dataOperating range: Up to 4.3 m3/h
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range: From 0°C to +35°C for domestic use
Maximum ambient temperature: + 40°C
Maximum operating pressure: JDBasic 2, JDBasic 4: 6 bar (600 kPa) JDBasic 5, JDBasic 7: 8 bar (800 kPa)
Installation: Fixed in a horizontal position
Special executions on request: Other voltages and/or frequencies.
JDBasic 2, JDBasic 4
TM0
0 9
976
10
97
TM0
2 84
55 0
204
H2
H
GB
V
X
Z
HH
1
A
Hydraulic data (n ≈ 2850 min -1)
Pumptype
Ejectortype
Suctiondepth
Delivery pressure in bar
1.5 2.0 2.5 3.0 3.5 4.0
Capacity table in [l/h]
JDB
asic
2
E25
9 1813 1080 446 33 / /
12 1426 720 225 / / /
15 900 326 / / / /
E30
9 1753 1286 812 524 261 46
12 1345 965 608 356 162 0
15 1166 761 452 228 45 /
JDB
asic
4
E25
9 2386 1756 1097 515 126 /
12 1930 1190 536 87 / /
15 1459 773 252 / / /
E30
12 / 1240 872 566 329 156
15 / 1028 701 449 255 96
18 / 785 527 302 150 15
21 / 635 374 180 39 /
Pump type
Dimensions [mm]DNA DNM DNE
Ejector Packing dimensionsVol
[m3]
Wei
gh
t[k
g]
A[mm]
H[mm]
H1[mm]
x y zL/A
[mm]L/B
[mm]L/H
[mm]A B C E G I H H1 H2
JDBasic 2 365 180 90 202 140 9,5 225 47 92 G 1 ¼ G 1 G 1 97 295 243 G 1 G 1 G 1 ¼ 452 218 257 0.025 13.9
JDBasic 4 385 180 90 202 140 9,5 225 47 92 G 1 ¼ G 1 G 1 97 295 243 G 1 G 1 G 1 ¼ 492 224 277 0.025 16.6
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
JDBasic 21 x 220-240 0.69 0.44 0.6 3.2 14 450
3 x 220-240/380-415
0.66 0.44 0.6 2.6/1.5 - -
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
JDBasic 41 x 220-240 0.79 0.75 1 3.8 16 450
3 x 220-240/380-415
0.64 0.75 1 2.6/1.5 - -
18
JDBasic Technical data
JDBasic 5, JDBasic 7
Instructions for conversionConversion from JDBasic 5, JDBasic 7 to JPBasic 5, JPBasic 7
Screw the nozzle (9) into the seat in the ejector body (2) and the Venturi tube (8). Position the O-rings (27) and (29) in their respective seats and fix the ejector body (2) onto the pump body (1) with the two screws (53).
Conversion from JPBasic 5, JPBasic 7 to JDBasic 5, JDBasic 7
Slacken and remove the two joining screws (53) between the ejector body (2) and the pump body (1). Collect the O-rings (27) and (29).
TM0
2 84
57 0
204
CA
E
B
DNM
G
I Ø
V
CA
EX
V
Z
HH
1
Hydraulic data (n ≈ 2850 min -1)
Pumptype
Ejectortype
Suctiondepth
Delivery pressure [bar]
3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0
Capaticy table [l/h]
JDB
asic
5
E 20
9 3412 2769 2090 1363 586 / / / / / /
12 3065 2400 1719 952 143 / / / / / /
15 2643 2000 1257 495 / / / / / / /
18 2289 1593 826 0 / / / / / / /
E 25
15 2745 2244 1761 1257 814 435 77 / / / /
18 2465 1969 1477 997 584 218 / / / / /
21 2206 1712 1224 779 388 45 / / / / /
E 30
21 1797 1615 1368 1106 861 658 472 312 163 25 /
24 1652 1484 1217 962 740 547 378 220 67 / /
27 1520 1333 1069 841 636 448 287 139 / / /
JDB
asic
7
E 20
9 / 3431 2751 2033 1236 448 / / / / /
12 / 3043 2324 1554 763 0 / / / / /
15 / 2665 1936 1145 344 / / / / / /
18 / 2244 1478 675 / / / / / / /
E 25
15 / 2840 2324 1806 1296 849 463 138 / / /
18 / 2535 2038 1523 1049640286 / / / /
21 / 2267 1757 1257 817 424 91 / / / /
24 / 1970 1458 989 583 226 / / / / /
E 30
21 / 1812 1671 1419 1163 919 716 531 377 226 91
24 / 1668 1549 1278 1023 791 619 445 297 156 13
27 / 1541 1395 1145 906 700 521 351 206 62 /
Pump typeDimensions [mm]
DNA DNM DNEEjector Packing dimensions [mm]
Vol
[m3]
Wei
gh
t[k
g]
A[mm]
H[mm]
H1[mm]
x y z L/A L/B L/HA B C E G I H H1 H2
JDBasic 5 388 210 50 197 145 11 255 53 108 G 1 ¼ G 1 G 1 97 295 243 G 1 G 1 G 1 ¼ 427 246 307 0.032 31
JDBasic 7 462 210 50 197 145 11 255 53 108 G 1 ¼ G 1 G 1 97 295 243 G 1 G 1 G 1 ¼ 522 246 307 0.039 35
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
JDBasic 5 1 x 220-240 1.56 1.1 1.5 7 31.5 450
JDBasic 7 1 x 220-240 2.1 1.85 2.5 8.3 40 450
TM0
0 9
980
10
97
& T
M0
0 9
981
10
97
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
JDBasic 5 3 x 220-240/380-415 1.45 1.1 1.5 4.7/2.7
JDBasic 7 3 x 220-240/380-415 1.78 1.85 2.5 5.6/3.2
19
CHBasic CHBasic
Performance range
TM0
2 89
33 1
804
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
60
H[m]
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Q [l/s]
0
100
200
300
400
500
600
p
[kPa]CHBasic
50 Hz
2
3
4
20
CHBasic General data
CHBasic 2, CHBasic 3, CHBasic 4
ApplicationsMultistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general.
Constructional featuresPump
Pump body in cast iron. Motor support in die-cast aluminium, seal holder in stainless steel.
Mechanical seal in carbon/ceramic. Shaft in stainless steel. Rotors, diffuser bodies and diffusers in technopol-ymer. Adjustment rings in stainless steel.
Motor
Continuous service asynchronous motor (2 poles) cooled by external fan.
Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for protection in the three-phase version. Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz
3 x 220-240/380-415 V, 50 Hz.
Material specification
Gr7
896
TM0
2 9
06
5 32
04
Pos. Description Material
1 Pump body Cast iron EN-GJL-200
3 Support Cast iron EN-GJL-200
4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2
7 Shaft Stainless steel AISI 303 X10 CrNiS 18 9
16 Mechanical seal Carbon/Ceramic
28 O-ring gasket NBR
36
1
4 16 728
21
CHBasic Technical data
Technical dataOperating range: From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive, chemically neutral and close to the characteristics of water.
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth: 8 metres (800 kPa)
Maximum operating pressure: CHBasic 2, CHBasic 3, CHBasic 4: 6 bar (600 kPa)
Installation: Fixed in a horizontal position
Special executions on request: Other voltages and/or frequencies.
Curve conditionsThe performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
22
CHBasic Technical data
CHBasic 2
CHBasic 3
TM0
2 9
06
2 17
04
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
CHBasic 21x220-240 0.72 0.45 0.6 3.2 10 450
3x220-240/380-415 0.7 0.45 0.6 2.2/1.3 - -
B
GI Ø
H
H2DN
AH
1
A
DNMC
E F
TM0
2 9
00
9 1
3040.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50[m]H
0
100
200
300
400
[kPa]P
0
20
40
60
80
100
120
140
160[ft]H
0 10 20 30 40 50 60 70Q [l/min]
0 2 4 6 8 10 12 14 16 Q [IMP GPM]
0 2 4 6 8 10 12 14 16 18 Q [US GPM]
0.0 0.2 0.4 0.6 0.8 1.0 1.2 Q [l/s]
Pump type
Dimensions [mm]Packing dimensions
[mm] Vol
[m3]Weight
[kg]A B C E F G I ø H H1 H2 DNA DNM L/A L/B L/H
CHBasic 2 406 175 122 207 13.5 111 9 200 179 143.5 Rp 1 Rp 1 480 212 265 0.027 12.5
TM0
2 9
06
2 17
04
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
CHBasic 31x220-240 1.2 0.75 1 5.3 20 450
3x220-240/380-415 1.2 0.75 1 3.8/2.2 - -
B
GI Ø
H
H2DN
AH
1
A
DNMC
E F
TM0
2 9
010
130
40.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55[m]H
0
100
200
300
400
500
[kPa]P
0
20
40
60
80
100
120
140
160
[ft]H
0 10 20 30 40 50 60 70 80 90 Q [l/min]
0 2 4 6 8 10 12 14 16 18 20 Q [IMP GPM]
0 2 4 6 8 10 12 14 16 18 20 22 24 Q [US GPM]
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Q [l/s]
Pump type
Dimensions [mm]Packing dimensions
[mm] Vol
[m3]Weight
[kg]A B C E F G I ø H H1 H2 DNA DNM L/A L/B L/H
CHBasic 3 425 175 122 207 13.5 111 9 213 179 143.5 Rp 1 Rp 1 480 212 265 0.027 15.4
23
CHBasic Technical data
CHBasic 4
TM0
2 9
06
2 17
04
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
CHBasic 41x220-240 1.2 0.8 1.1 5.3 20 450
3x220-240/380-415 1.2 0.8 1.1 3.8/2.2 - -
B
GI Ø
H
H2DN
AH
1
A
DNMC
E F
TM0
2 9
011
130
40 1 2 3 4 5 6 7 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50[m]H
0
100
200
300
400
[kPa]P
0
20
40
60
80
100
120
140
160[ft]H
0 20 40 60 80 100 120 Q [l/min]
0 4 8 12 16 20 24 28 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 Q [US GPM]
0.0 0.4 0.8 1.2 1.6 2.0 Q [l/s]
Pump typeDimensions [mm]
Packing dimensions[mm] Vol
[m3]Weight
[kg]A A1 B C E F G H H3 I DNA DNM L/A L/B L/H
CHBasic 4 425 175 122 207 13.5 111 9 213 179 143.5 Rp 1 Rp 1 480 212 265 0.027 15.4
24
CHBasic PT General data
CHBasic PT
ApplicationsMultistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general.
The set is composed of a diaphragm tank with capacity 19 litres, pressure switch for automatic operation, pres-sure gauge, JPBasic electric pump complete with power cable and plug, kit for coupling the pump and the tank, all assembled and ready for installation.
Note: Vertical 8 litres or 18 litres tanks are used in some markets.
Constructional featuresPump
Pump body in cast iron. Motor support in die-cast aluminium, seal holder in stainless steel.
Mechanical seal in carbon/ceramic. Shaft in stainless steel. Rotors, diffuser bodies and diffusers in technopol-ymer. Adjustment rings in stainless steel.
Motor
Continuous service asynchronous motor (2 poles) cooled by external fan.
Built-in thermal and current overload protection and a capacitor permanently in circuit.
Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz.
Tank
Horizontal type, capacity 19 litres, with butyl diaphragm, complete with feet on the bottom and brackets for fixing the pump on top
Material specification
TM0
2 9
06
1 17
04
TM0
2 9
06
5 32
04
Pos. Description Material
1 Pump body Cast iron EN-GJL-200
3 Support Cast iron EN-GJL-200
4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2
7 Shaft AISI 303 stainless steel X 10 Cr NiS 18 9
16 Mechanical seal Carbon/Ceramic
28 O-ring gasket NBR
36
1
4 16 728
25
CHBasic PT Technical data
Technical dataOperating range: From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth: 8 metres (800 kPa)
Maximum operating pressure: CHBasic 2 PT, CHBasic 3 PT, CHBasic 4 PT: 6 bar (600 kPa)
Installation: Fixed in a horizontal position
Special executions on request: Other voltages and/or frequencies.
Curve conditionsThe performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
CHBasic 2 PT
TM0
2 9
06
6 1
704
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
CHBasic 2 PT
1 x 220-240
0.72 0.45 0.60 3.2 12.5 450
CHBasic 3 PT 1.2 0.75 1.0 5.3 12.5 450
CHBasic 4 PT 1.2 0.80 1.1 5.3 16 450
H1
H
A1
A B
D
TM0
2 89
39 1
7040 1 2 3 4 5 6 7 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55[m]H
0
100
200
300
400
500
[kPa]P
0
20
40
60
80
100
120
140
160
[ft]H
0 20 40 60 80 100 120 Q [l/min]
0 4 8 12 16 20 24 28 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 Q [US GPM]
0.0 0.4 0.8 1.2 1.6 2.0 Q [l/s]
CHBasic 3CHBasic 2 CHBasic 4
Pump typeDimensions [mm]
Packing dimensions[mm] Vol
[m3]Weight
[kg]A A1 B D H H1 L DNA DNM L/A L/B L/H
CHBasic 2 PT 550 405 270 281 290 200 330 Rp 1 Rp 1 576 366 554 0.107 17.7
CHBasic 3 PT 550 425 270 281 290 200 330 Rp 1 Rp 1 576 366 554 0.107 20.6
CHBasic 4 PT 550 425 270 281 290 200 330 Rp 1 Rp 1 576 366 554 0.107 20.6
26
CHBasic PS General data
CHBasic PS
ApplicationsMultistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general.
Constructional featuresPump
Pump body in cast iron. Motor support in die-cast aluminium, seal holder in stainless steel.
Mechanical seal in carbon/ceramic. Shaft in stainless steel. Rotors, diffuser bodies and diffusers in technopol-ymer. Adjustment rings in stainless steel.
Motor
Continuous service asynchronous motor (2 poles) cooled by external fan.
Built-in thermal and current overload protection and a capacitor permanently in circuit.
Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz.
Material specification
Gr7
918
TM0
2 9
06
5 32
04
Pos. Description Material
1 Pump body Cast iron EN-GJL-200
3 Support Cast iron EN-GJL-200
4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2
7 Shaft AISI 303 stainless steel X 10 Cr NiS 18 9
16 Mechanical seal Carbon/Ceramic
28 O-ring gasket NBR
36
1
4 16 728
27
CHBasic PS Technical data
Technical dataOperating range: From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth: 8 metres (800 kPa)
Maximum operating pressure: CHBasic 2 PS, CHBasic 3 PS, CHBasic 4 PS: 6 bar (600 kPa)
Installation: Fixed in a horizontal position
Special executions on request: Other voltages and/or frequencies.
Curve conditionsThe performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
CHBasic PS
TM0
2 9
06
4 17
04
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
CHBasic 2 PS
1 x 220-240
1.75 0.45 0.60 3.2 10 450
CHBasic 3 PS 1.20 0.75 1.00 5.3 20 450
CHBasic 4 PS 1.20 0.80 1.10 5.3 20 450
B
G
D
H2H
I ø
AC
F
DNM
E
H1
H3 DN
A
DN
M
TM0
2 89
39 1
7040 1 2 3 4 5 6 7 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55[m]H
0
100
200
300
400
500
[kPa]P
0
20
40
60
80
100
120
140
160
[ft]H
0 20 40 60 80 100 120 Q [l/min]
0 4 8 12 16 20 24 28 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 Q [US GPM]
0.0 0.4 0.8 1.2 1.6 2.0 Q [l/s]
CHBasic 3CHBasic 2 CHBasic 4
Pump typeDimensions [mm]
Packing dimensions[mm] Vol
[m3]Weight
[kg]A B C D E F G H H1 H2 H3 I DNA DNM L/A L/B L/H
CHBasic 2 PS 405 281 122 196 205 14 111 238 205 200 144 9 Rp 1 Rp 1 449 309 244 0.03 14
CHBasic 3 PS 425 281 122 196 205 14 111 238 205 200 144 9 Rp 1 Rp 1 449 309 244 0.031 17
CHBasic 4 PS 425 281 122 196 205 14 111 238 205 200 144 9 Rp 1 Rp 1 449 309 244 0.03 17
28
CHBasic PC General data
CHBasic PC
ApplicationsMultistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general.
OperationThe pump is equipped with a Presscontrol (PC) which controls, manages and commands it, regulating its oper-ation, limiting the number of starts and guaranteeing maximum pressure stability inside the hydraulic circuit in which it is installed.
The automatic devices is the result of a series of studies conducted to optimise the efficiency of the system while preserving the structural features and sturdiness of existent devices.
Automatic sets differ from the traditional systems equipped with a pressure switch based on pump starting and stopping as they avoid sudden variations and drops in pressure. They are basically equipped with a double control device, as built-in electrical circuit gathers the data regarding pressure and water flow in the system and processes them to allow the pump to operate under optimum performance conditions.
The automatic device is supplied pre-installed on the pump, requires no type of regulation and considerably reduces overall dimensions by totally eliminating the bulky tanks used traditional installations.
Optimised management of the hydraulic installation and its components
1. Enables the system to operate only when there is wa-ter present; if, for any reason, no water reaches the system, it blocks the pump, so that it does not oper-ate while dry. In this case the ALARM LED lights up.
2. Maintains pump operation when the appliances are opened by one or more users, in order to prevent sud-den changes in pressure. When an appliance is opened the depression created in the system acts on
the membrane which gradually releases a spring. The sensors detect the movement, send a signal to the electronic unit which enables pump start-up.
3. Automatically stops the pump when the users stop drawing water. When the appliances are closed, un-der the effect of the rise in pressure within the hy-draulic system, the membrane totally compresses the spring. This new situation is analysed by the sensors which send the unit a signal to stop the pump. The stop is timed in order to prevent the pump from be-ing subjected to repeated starts caused by users opening and closing the appliances within a few sec-onds of each other. Furthermore, if boilers are sup-plied, the continuous delivery of hot water is guaranteed by timing the stops.
4. Instant pump start when one of the appliances is opened even with a minimum amount of water drawn.
5. In the event of leaks in the system (drips or small trickles) the device limits the number of cycles, pro-longing pump running time by about 10 seconds.
6. It eliminates water hammering by means of a spe-cific shock absorber which absorbs the effect.
7. Manual reset in the event of a breakdown in the hy-draulic circuit or of overload protector intervention; in this case, after eliminating the cause, press the "RESET" button positioned on the terminal board cover for a few seconds until the "ALARM" LED switches off.
8. In the event of a power cut, automatic reset as soon as the power is restored.
9. The system is self-protected against overheating. When there is an excess in temperature inside the motor windings, this operation is carried out auto-matically. It is also restored automatically once the temperature has dropped below the level which guarantees operation without damage to the system.
Constructional featuresPump
Pump body in cast iron. Motor support in die-cast aluminium, seal holder in AISI 304 steel.
Mechanical seal in carbon/ceramic. Rotor shaft in AISI 304 steel. Rotors, diffuser bodies and diffusers in tech-nopolymer. Adjustment rings in stainless steel.
Motor
Continuous service asynchronous motor (2 poles) cooled by external fan.
Built-in thermal and current overload protection and a capacitor permanently in circuit.
Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz.
Gr7
916
29
CHBasic PC Technical data
Material specification
TM0
2 9
06
5 32
04
Pos. Description Material
1 Pump body Cast iron EN-GJL-200
3 Support Cast iron EN-GJL-200
4 Impeller Noryl GFN 2
6 Diffuser Noryl GFN 2
7 Shaft AISI 303 stainless steel X 10 Cr NiS 18 9
16 Mechanical seal Carbon/Ceramic
28 O-ring gasket NBR
36
1
4 16 728
30
CHBasic PC Technical data
Technical dataOperating range: From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth: 8 metres (800 kPa)
Maximum operating pressure: CHBasic 2 PC, CHBasic 3 PC, CHBasic 4 PC: 6 bar (600 kPa)
Installation: Fixed in a horizontal position
Special executions on request: Other voltages and/or frequencies.
Curve conditionsThe performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
CHBasic PC
TM0
2 9
06
3 17
04
Pump type
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
CHBasic 2 PC
1 x 220-240
0.72 0.45 0.6 3.2 10 450
CHBasic 3 PC 1.2 0.75 1.0 5.3 20 450
CHBasic 4 PC 1.2 0.80 1.1 5.3 20 450
BG
I ø
DMNC
DN
A
H
EF
A
TM0
2 89
39 1
7040 1 2 3 4 5 6 7 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55[m]H
0
100
200
300
400
500
[kPa]P
0
20
40
60
80
100
120
140
160
[ft]H
0 20 40 60 80 100 120 Q [l/min]
0 4 8 12 16 20 24 28 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 Q [US GPM]
0.0 0.4 0.8 1.2 1.6 2.0 Q [l/s]
CHBasic 3CHBasic 2 CHBasic 4
Pump typeDimensions [mm]
Packing dimensions[mm] Vol
[m3]Weight
[kg]A B C E F G H I ø DNA DNM L/A L/B L/H
CHBasic 2 PC 406 212 122 207 13.5 111 376 9 Rp 1 Rp 1 524 248 309 0.04 14
CHBasic 3 PC 425 212 122 207 13.5 111 376 9 Rp 1 Rp 1 524 248 309 0.04 16
CHBasic 4 PC 425 212 122 207 13.5 111 376 9 Rp 1 Rp 1 524 248 309 0.04 16
31
NSBasic NSBasic Single impeller
Performance range
TM0
2 89
34 1
80
4
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
H[m]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s]
0
100
200
300
400
500
600
700
p[kPa]
NSBasic50 Hz
6-40
13-18
3-40
4-23
5-33
5-50
5-60
6-30
32
NSBasic General data
NSBasic single impeller pumps
ApplicationsSingle impeller centrifugal pump designed for lifting water in domestic, civil, industrial and agricultural installations and for decanting, mixing and irrigating uses.
Constructional featuresPump
Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer and cast iron impeller. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension.
Motor
Induction motor, closed and cooled with external fan. Rotor mounted on oversized greased sealed-for-life ball bearing to ensure silent running and long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for the protection in the three-phase version. Manufactured according to standard EN 60335-2-41.
Motor protection: IP 44 Terminal box protection: IP 55 for the single-phase
version Insulation class: F Standard voltage: 1x220-240 V, 50 Hz
3x220-240/380-415 V, 50 Hz.
Material specification
Gr7
897
TM0
2 9
070
170
4
Description Material Pump types
1 Pump body Cast iron EN-GJL-200
3 Support Cast iron EN-GJL-200
4 Impeller Noryl GFN 2
7 ShaftX 12 CrNi 1810 NSBasic 4-23 - NSBasic 13-18
X 10 CrNi 1809 NSBasic 5-33
16 Mechanical seal Carbon/Ceramic
28 O-Ring Gasket NBR
16
1 4 28 3
7
33
NSBasic Technical data
Technical dataOperating range: From 1.8 to 16.8 m3/h with head up to 34 metres
Liquid quality requirements: Clean, free from solids or abrasive substances, non viscous, non aggressive, noncrystallized, chemically neutral, close to the characteristics of water.
Liquid temperature range: NSBasic 4-23, NSBasic 5-33, NSBasic 13-18: from -10°C to + 50°C
Maximum ambient temperature: +40°C
Maximum operating pressure: NSBasic 4-23, NSBasic 5-33, NSBasic 13-18: 6 bar (600 kPa)
Installation: Fixed in a horizontal or vertical position, as long as the motor is above the pump
Special versions on request: Other voltages and/or frequencies.
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
NSBasic 4-23
TM0
2 9
089
180
4Sin
gle
imp
elle
r
Pumptype
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
NSBasic 4-23 1x220-240 0.65 0.37 0.5 3.0 10 450
NSBasic 4-23 3x220-240/380-415 0.64 0.37 0.5 2.3/1.3 - -
TM0
2 9
012
130
4
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h]
0
5
10
15
20
[m]H
0
80
160
[kPa]P
0
20
40
60
[ft]H
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h]
0.0
0.2
0.4[kW]
P2
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Q [l/s]
0 10 20 30 40 50 60 70 80 90 Q [l/min]
0 4 8 12 16 20 Q [IMP GPM]
0 4 8 12 16 20 24 Q [US GPM]
0.0
0.2
0.4
[hp]P2
0
20
40[%]Eta
Eta
P2
Pumptype
Dimensions [mm]DNA DNM
Packing dimensions [mm] Vol
[m3]Weight
[kg]A B C D E F G I H H1 H2 L/A L/B L/H
NSBasic 4-23 275 160 50 100 50 15 110 9 205 85 120 Rp 1 Rp 1 362 222 262 0.021 10.3
34
NSBasic Technical data
NSBasic 5-33
NSBasic 13-18
TM0
2 9
089
180
4
Pumptype
Electrical data
Voltage[V]
P1Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
NSBasic 5-33 1x220-240 1.3 0.75 1 6.0 20 450
NSBasic 5-33 3x220-240/380-415 1.2 0.75 1 4.3/2.5 - -
TM0
2 9
013
130
4
0 1 2 3 4 5 6 7 8 Q [m³/h]
0
10
20
30
[m]H
0
80
160
240
320[kPa]
P
0
20
40
60
80
100
[ft]H
0 1 2 3 4 5 6 7 8 Q [m³/h]
0.0
0.4
0.8[kW]
P2
0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [l/s]
0 20 40 60 80 100 120 Q [l/min]
0 4 8 12 16 20 24 28 32 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 36 Q [US GPM]
0.0
0.4
0.8
[hp]P2
0
20
40[%]Eta
Eta
P2
Pumptype
Dimensions [mm]DNA DNM
Packing dimensions[mm] Vol
[m3]Weight
[kg]A B C D E F G I H H1 H2 L/A L/B L/H
NSBasic 5-33 300 185 50 108 58 15 140 9 235 100 135 Rp 1 Rp 1 392 232 262 0.024 14.7
TM0
2 9
089
180
4
Pumptype
Electrical data
Voltage[V]
P1Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
NSBasic 13-18 1x220-240 1.1 0.75 1 4.6 20 450
NSBasic 13-18 3x220-240/380-415 1.1 0.75 1 3.6/2.1 - -
TM0
2 9
014
130
4
0 2 4 6 8 10 12 14 16 Q [m³/h]
0
5
10
15
20
[m]H
0
80
160
[kPa]P
0
20
40
60
[ft]H
0 2 4 6 8 10 12 14 16 Q [m³/h]
0.0
0.4
0.8[kW]
P2
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s]
0 40 80 120 160 200 240 Q [l/min]
0 5 10 15 20 25 30 35 40 45 50 55 60 Q [IMP GPM]
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Q [US GPM]
0.0
0.4
0.8
[hp]P2
0
20
40[%]Eta
Eta
P2
Pumptype
Dimensions [mm]DNA DNM
Packing dimensions[mm] Vol
[m3]Weight
[kg]A B C D E F G I H H1 H2 L/A L/B L/H
NSBasic 13-18 312 169 45 114 69 15 110 9 210 210 125 Rp 1½ Rp 1½ 392 232 262 0.024 14
35
NSBasic General data
NSBasic twin impeller pumps
ApplicationsMuliti-stage centrifugal pump with opposed twin impellers. Designed for use in pressurisation units for water supply systems and for supplying pressurised tanks. Suitable also for sprinkling, irrigation and other water supply application.
Constructional featuresPump
Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer and cast iron impeller. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension.
Motor
Induction motor, closed and cooled with external fan. Rotor mounted on oversized greased sealed-for-life ball bearing to ensure silent running and long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for the protection in the three-phase version. Manufactured according to standard EN 60335-2-41.
Motor protection: IP 44 Terminal box protection: IP 55 for the single-phase
version up to and including 0.75 kW
Insulation class: F Standard voltage: 1x220-240 V, 50 Hz
3x220-240/380-415 V, 50 Hz.
Material specification
Gr7
928
TM0
2 9
06
9 1
704
Description Material Pump types
1 Pump bodyCast iron EN-GJL-200
3 SupportCast ironEN-GJL-200
4 ImpellerNoryl GFN 2
NSBasic 3-40 - NSBasic 5-50 - NSBasic 6-30 - NSBasic 6-40
Ultem 2300 NSBasic 5-60
7 Shaft Stainless steel ANSI X12 CrNi 1810
16 Mechanical seal Carbon/Ceramic
28 O-ring gasketImpregnated Cellulose
34 Intermediate DiscCast iron EN-GJL-200
34 3
1 4 28 16 7
36
NSBasic Technical data
Technical dataOperating range: From 1.5 to 10.8 m3/h with head up to 60 metres.
Liquid quality requirements: clean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water.
Liquid temperature range: NSBasic 3-40, NSBasic 5-50, NSBasic 6-30, NSBasic 6-40: from –10°C to + 50°C NSBasic 5-60: from –15°C to + 110°C
Maximum ambient temperature: +40°C
Maximum operating pressure: NSBasic 3-40, NSBasic 5-50, NSBasic 6-30, NSBasic 6-40: 6 bar ( 600 kPa) NSBasic 5-50, NSBasic 5-60: 8 bar ( 800 kPa)
Installation: Fixed in a horizontal or vertical position, as long as the motor is above the pump.
Special versions on request: Other voltages and/or frequencies.
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
NSBasic 3-40
TM0
2 9
088
180
4Tw
in im
pel
ler
Pumptype
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
NSBasic 3-40 1x220-240 1.2 0.75 1 5.5 20 450
NSBasic 3-40 3x220-240/380-415 1.2 0.75 1 3.8/2.2 - -
TM0
2 9
015
130
4
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h]
0
10
20
30
40
[m]H
0
100
200
300
400[kPa]
P
0
40
80
120
[ft]H
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h]
0.0
0.4
0.8[kW]
P2
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Q [l/s]
0 10 20 30 40 50 60 70 80 90 Q [l/min]
0 4 8 12 16 20 Q [IMP GPM]
0 4 8 12 16 20 24 Q [US GPM]
0.0
0.4
0.8
[hp]P2
0
20
40[%]Eta
Eta
P2
Pumptype
Dimensions [mm]DNA DNM
Packing dimensions[mm] Vol
[m3]Weight
[kg]A B C D E F G I H H1 H2 L/A L/B L/H
NSBasic 3-40 342 180 76 148 72 15 148 9.5 235 100 135 Rp 1 Rp 1 392 232 262 0.024 16.1
37
NSBasic Technical data
NSBasic 5-50
NSBasic 5-60
TM0
02
90
88 1
804
Pumptype
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
NSBasic 5-50 1x220-240 1.9 1.1 1.5 8.3 31.5 450
NSBasic 5-50 3x220-240/380-415 2.0 1.1 1.5 6.0/3.5 - -
TM0
2 9
016
130
4
0 1 2 3 4 5 6 7 Q [m³/h]
0
10
20
30
40
50[m]H
0
100
200
300
400
[kPa]P
0
40
80
120
160[ft]H
0 1 2 3 4 5 6 7 Q [m³/h]
0.0
0.8
1.6[kW]
P2
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 Q [l/s]
0 10 20 30 40 50 60 70 80 90 100 110 120 Q [l/min]
0 4 8 12 16 20 24 28 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 Q [US GPM]
0.0
0.8
1.6
[hp]P2
0
20
40[%]Eta
Eta
P2
Pumptype
PhaseDimensions [mm]
DNA DNMPacking dimensions
[mm] Vol
[m3]Weight
[kg]A B C D E F G I H H1 H2 L/A L/B L/H
NSBasic 5-50 1 370 210 75 144 69 15 165 11.5 268 118 150 Rp 1¼ Rp 1 415 235 295 0.029 23.3
NSBasic 5-50 3 370 210 75 144 69 15 165 11.5 268 118 150 Rp 1¼ Rp 1 415 234 295 0.029 23.8
TM0
2 9
088
180
4
Pumptype
Electrical data
Voltage [V]P1
Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
NSBasic 5-60 1x220-240 2.7 1.8 2.5 12.8 40 450
NSBasic 5-60 3x220-240/380-415 2.5 1.8 2.5 8.4/4.8 - -
TM0
2 9
017
130
4
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
0
20
40
60
[m]H
0
200
400
600
[kPa]P
0
40
80
120
160
200
[ft]H
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
0
1
2[kW]
P2
0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [l/s]
0 20 40 60 80 100 120 140 Q [l/min]
0 4 8 12 16 20 24 28 32 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 36 40 Q [US GPM]
0
1
2
[hp]P2
0
20
40[%]Eta
Eta
P2
Pumptype
Dimensions [mm]DNA DNM
Packing dimensions[mm] Vol
[m3]Weight
[kg]A B C D E F G I H H1 H2 L/A L/B L/H
NSBasic 5-60 370 210 75 144 69 15 165 11.5 268 118 150 Rp 1¼ Rp 1 415 234 295 0.032 23.8
38
NSBasic Technical data
NSBasic 6-30
NSBasic 6-40
TM0
2 9
09
0 1
804
Pumptype
Electrical data
Voltage[V]
P1Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
NSBasic 6-301x220-240V 1.56 1.1 1.5 7.1 25 450
3x220-240/380-415 1.56 1.1 1.5 5.4/3.1 - -
TM0
2 9
018
130
4
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
0
10
20
30
40
[m]H
0
100
200
300
400[kPa]
P
0
40
80
120
[ft]H
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
0.0
0.8
1.6[kW]
P2
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [l/s]
0 20 40 60 80 100 120 140 160 180Q [l/min]
0 4 8 12 16 20 24 28 32 36 40 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM]
0.0
0.8
1.6
[hp]P2
0
20
40[%]Eta
Eta
P2
Pumptype
Dimensions [mm]DNA DNM
Packing dimensions[mm] Vol
[m3]Weight
[kg]A B C E F G I H H1 L/A L/B L/H
NSBasic 6-30 387 205 88 179 20 145 11 233 108 Rp 1½ Rp 1 415 234 295 0.028 21.5
TM0
2 9
09
0 1
804
Pumptype
Electrical data
Voltage[V]
P1Max.[kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
NSBasic 6-401x220-240V 2 1.85 2.5 9 40 450
3x220-240/380-415
2.0 1.85 2.5 6.2/3.6 - -
TM0
2 9
019
130
4
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
0
10
20
30
40
[m]H
0
100
200
300
400[kPa]
P
0
40
80
120
[ft]H
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
0.0
0.8
1.6[kW]
P2
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [l/s]
0 20 40 60 80 100 120 140 160 180Q [l/min]
0 4 8 12 16 20 24 28 32 36 40 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM]
0.0
0.8
1.6
[hp]P2
0
20
40[%]Eta
Eta
P2
Pump typeDimensions [mm]
DNA DNMPacking dimensions
[mm] Vol
[m3]Weight
[kg]A B C E F G I H H1 L/A L/B L/H
NSBasic 6-40461 205 88 179 20 145 11 233 108 Rp 1½ Rp 1 510 234 285 0.034 25.9
387 205 88 179 20 145 11 233 108 Rp 1½ Rp 1 415 234 295 0.028 22
39
KPBasicKPBasic
Performance range
TM0
2 8
937
18
04
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17Q [m³/h]
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
10.5
H[m]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s]
0
10
20
30
40
50
60
70
80
90
100
p[kPa]
KPBasic50 Hz
200
300 A
600 (A)
40
KPBasic General data
KPBasic
ApplicationsThe submersible pump from the KPBasic series is designed mainly for automatically operated fixed appli-cations in domestic use, draining basements and garages which are subject to flooding.
Thanks to its compact, easy to handle design, it can also be used as a portable pump for emergencies such as lifting water from tanks or rivers, emptying swimming pools, fountains, excavations and underpasses. It is also ideal for gardening and hobbies in general.
The level switch allows fixed installation and guarantees automatic pump operation.
Constructional featuresPump
Water-resistant technopolymer pump body, impeller, top body and suction grid. Stainless steel motor casing, rotor shaft and screws. Triple "O" ring seals interposed with oil chamber.
Motor
Continous duty submersible induction motor. Stator fitted in an airtight stainless steel casing covered by a top body which encases cabling, microswitch and capacitor. Rotor mounted on oversized greased sealed-for-life ball bearings selected to guarantee silent running and long life. Built-in thermal and current over-load protection and a capacitor which is permanently in circuit in the single-phase version.
KPBasic 200: Supplied standard with 10 metres of H05 RN-F power cable.
KPBasic 300 A: Supplied standard with 10 metres of H05 RN-F power cable. Note: 5 m cable om request.
KPBasic 600: Supplied standard with 10 metres of H07 RN-F power cable.
KPBasic 600 A: Supplied standard with 10 metres of H07 RN-F power cable. Note: 5m cable on request.
Degree of protection: IP 68 Insulation class: F
Manufactured according to standard EN 60335-2-41.
Standard voltage: 1 x 220-240V, 50 Hz 3 x 380-415V, 50 Hz.
Descriptions and materials
Gr7
913
Table of performance ranges and possible applications
KPBasic
DNM connections Rp 1¼
Flow rate Q [m3/h] Max. 16
Head H [m] Max. 10.8
Temperature t [oC] Max. +40
Rain water
Clean waste water
TM0
2 84
68
320
4
Pos. Descriptions Materials
1 Pump body Noryl GFN 2
4 impeller Noryl GFN 2
29 O-ring gasket NBR
32 Stop ring Stainless steel 12E
54
Motor
- Top bodyStainless steel AISI 304 X5 CrNi 1810
- Shaft Stainless steel AISI 304 X5 CrNi 1810
78 Pressure disc Noryl GFN 2
79 Suction grid Noryl GFN 2
1
78
79 32 4
7354
29
41
Technical dataKPBasic
Technical dataOperation range: From 1 to 16 m3/h with head up to 10.2 metres Liquid quality requirements: Grey water without fibres
Granulometric passage though the suction grid: KPBasic 200 5 mm KPBasic 300A 10 mm KPBasic 600 10 mm KPBasic 600A 10 mm
Minimum draught depth: KPBasic 200 8 mm KPBasic 300A 85 mm KPBasic 600 38 mm KPBasic 600A 175 mm
Liquid temperature range: From 0°C to +35°C Maximum immersion: 7 metres Maximum dry running time: 1 minute
Automatic float switch: Type name extension: A
Special versionson request: Other voltages and/or frequencies
Installation: Fixed or portable in a vertical position. The minimum pit dimensions for fixed installation with automatic operation are indicated in the drawing.
Curve conditionsThe performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
KPBasic 300 AMinimum dimension for the pit for KPBasic 300 A with automatic float switch
KPBasic 600 AMinimum dimension for the pit for KPBasic 600 A with automatic float switch
TM0
2 9
100
180
4
400
400
TM0
2 9
101
180
4
400
500
42
KPBasic Technical data
KPBasic 200
KPBasic 200, KPBasic 300A
KPBasic 300A
TM0
2 9
020
130
4TM
02
846
6 0
204
Pumptype
Electrical data
Voltage [V]P1
Max.[W]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
KPBasic 200 1x220-240 350 0.22 0.3 1.5 8 450
KPBasic 300A 1x220-240 350 0.22 0.3 1.5 8 450
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
0
2
4
6
8
[m]H
0
20
40
60
80[kPa]
P
0
5
10
15
20
25
[ft]H
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
0.0
0.1
0.2[kW]
P2
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [l/s]
0 20 40 60 80 100 120 140 160 Q [l/min]
0 4 8 12 16 20 24 28 32 36 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 36 40 44 Q [US GPM]
0.0
0.1
0.2
[hp]P2
0
20
40[%]Eta
Eta
P2
BA
D
E
H1 H
H2
Liv.
min
.
Liv.
max
.
TM0
2 9
021
130
4
0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
0
2
4
6
8
[m]H
0
20
40
60
80[kPa]
P
0
5
10
15
20
25
[ft]H
0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
0.0
0.1
0.2[kW]
P2
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 Q [l/s]
0 20 40 60 80 100 120 140 160 180 200 Q [l/min]
0 4 8 12 16 20 24 28 32 36 40 44 48 Q [IMP GPM]
0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 Q [US GPM]
0.0
0.1
0.2
[hp]P2
0
20
40[%]Eta
P2
Eta
Pumptype
Dimensions [mm] Liv. min. Liv. max.DNM
Packing dimensions [mm] Vol
[m3]Weight
[kg]A B D E H H1 H2 [mm] [mm] L/A L/B L/H
KPBasic 200 185 140 225 82 266 390 38,5 100 350 Rp 1¼ 207 227 312 0.016 4.5
KPBasic 300A 185 140 225 82 275 390 47,5 100 350 Rp 1¼ 207 227 312 0.016 4.6
43
KPBasic Technical data
KPBasic 600 (A) KPBasic 600 (A)
TM0
2 9
022
130
4
Pumptype
Electrical data
Voltage [V]P1
Max.[W]
P2
[kW]
P2
[hp]
In
[A]
Capacitor
[µF] [Vc]
KPBasic 600 1x220-240 800 0.55 0.75 3.4 14 450
KPBasic 600A 1x220-240 800 0.55 0.75 3.4 14 450
KPBasic 600 3x380-415 800 0.55 0.75 3.4 - -
0 2 4 6 8 10 12 14 16 Q [m³/h]
0
2
4
6
8
10[m]H
0
20
40
60
80
[kPa]P
051015202530
[ft]H
0 2 4 6 8 10 12 14 16 Q [m³/h]
0.0
0.2
0.4
0.6[kW]
P2
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s]
0 40 80 120 160 200 240 Q [l/min]
0 5 10 15 20 25 30 35 40 45 50 55 60 Q [IMP GPM]
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Q [US GPM]
0.00.20.40.60.8[hp]P2
0
10
20
30[%]Eta
Eta
P2
TM0
2 84
66
020
4
BA
D
E
H1 H
H2
Liv.
min
.
Liv.
max
.
Pumptype
Dimensions [mm] Liv. min. Liv. max.DNM
Packing dimensions [mm] Vol
[m3]Weight
[kg]A B D E H H1 H2 [mm] [mm] L/A L/B L/H
KPBasic 600 200 160 225 90 376 490 73 200 450 Rp 1 ¼ 207 227 422 0.021 7
KPBasic 600A 200 160 225 90 376 490 73 200 450 Rp 1 ¼ 207 227 422 0.021 6.7
44
PFBasicPFBasic
Performance range
TM0
2 8
935
180
4
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
60
H[m]
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Q [l/s]
0
100
200
300
400
500
600
p[kPa]
PF(P)Basic50 Hz
PFBasic 1-30
PFBasic 2-50
PFPBasic 2-50
45
PFBasic General data
PFBasic
ApplicationsPeripheral centrifugal pump with compact dimensions. Able to generate high heads and suitable for domestic installations, water supply systems, light gardening applications, draining and filling cisterns, as well as light industrial uses such as feeding pressurized boilers (anti-condensation).
Constructional featuresPump
Cast iron pump body and motor support with brass wear disc. Brass impeller. Carbon/ceramic mechanical seal.
Motor
Induction motor, closed and cooled with external venti-lation. Rotor mounted on oversized greased sealed-for-life ball bearings to ensure silent running and long life.
The motor incorporates a built-in thermal and current overload protection as well as a capacitor, switched on permanently.
Manufactured according to standard EN 60335-2-41.
Motor protection: IP 44
Terminal box protection: IP 55
Insulation class: F
Standard voltage: Single-phase 220-240 V, 50 Hz.
Other voltages and frequencies are available on request.
Material specification
GR7
90
1
TM0
2 9
071
170
4
Pos. Description Material
1 Pump body Cast iron EN-GJL-200
4 Impeller Brass PCu Zn 40 Pb2 5705-65
7 Shaft Stainless steel AISI 416X12 CrS 13
16 Mechanical seal Carbon/ceramic
28 O-ring gasket NBR rubber
1
28
4
16 7
46
PFBasic Technical data
Technical dataOperating range: From 0.3 to 2.7 m3/h with heads up to 53 metres.
Pumped liquid: Cclean, free from solids or abrasive substances, non viscous, non aggressive, non crys-tallized, chemically neutral, close to the characteristics of water.
Liquid temperature range: from 0°C to +35°C for domestic use (EN 60335-2-41)
From –10°C to +50°C for other uses.
Maximum ambient temperature: +40°C
Maximum operating pressure: - PFBasic 1-30: 6 bar (600 kPa) - PFBasic 2-50: 10 bar (1000 kPa)
Installation: Fixed in the horizontal position.
The performance curves are based on a kinematic viscosity value of 1 mm²/s and a density equal to 1000 kg/m3.
Curve tolerances according to ISO 9906, annex A.
Electrical data
Dimensions and weights
TM0
2 9
09
1 18
04
TM0
2 6
757
130
40.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [m³/h]
0
4
8
12
16
20
24
28
32
36
40
44
48
52
56[m]H
0
80
160
240
320
400
480
[kPa]p
0.0 0.2 0.4 0.6 Q [l/s]
PFBasic50 Hz
ISO 9906 Annex A
2-50
1-30
Model Voltage [V]P1 max.
[kW]P2
[kW]P2
[hp]In
[A]Capacitor
[µF] [Vc]
PFBasic 1-30 1 x 220-240 0.47 0.3 0.4 2 8 450
PFBasic 2-50 1 x 220-240 0.86 0.6 0.8 3.8 12.5 450
Model A B B1 C E F G I H H1 H2 DNA DNMPacking dimensions [mm] Volume
[m3]Weight
[kg]L/A L/B L/H
PFBasic 1-30 228 132 165 22 46 - 65 8 158 103 138 Rp 1 Rp 1 259 164 197 0.008 5.3
PFBasic 2-50 255 130 - 26 106 80 100 7 186 108 153 Rp 1 Rp 1 271 176 209 0.01 7.5
47
General dataPFPBasic
PFPBasic 2-50
ApplicationsSelf-priming pump with side liquid channel and star-shaped impeller, with excellent suction capacities even in unfavourable operating conditions such as the pres-ence of air bubbles or lack of continuity in the sucked liquid. Used in domestic, agricultural civil and industrial installations.
Constructional featuresPump
Cast iron pump body with brass pressure disc. Motor support and impeller completely made of brass, to avoid the risk of blockage. Carbon/ceramic mechanical seal. Stainless steel motor shaft.
Motor
Asynchronous motor, cooled by external fan. Rotor mounted on oversized, greased and sealed-for-life ball bearings to ensure quiet operation and long life.
The single-phase version has built-in thermal and current overload protection.
Manufactured according to standard EN60335-2-41.
Motor protection: IP 44 IP 55 terminal board protection
Insulation class: F
Standard voltage: Single-phase 220-240 V, 50 Hz. Other voltages and frequencies are available on request.
Materials
Gr7
90
0G
ener
al d
ata
TM0
2 9
072
170
4
Pos. Description Material
1 Pump bodyCast iron EN-GJL-200, with brass wear ring PCuZn 40 Pb2 5705/65
3 Motor support Brass PCu Zn 40 Pb2 5705/65
4 Impeller Brass PCu Zn 40 Pb2 5705/65
7 ShaftStainless steel AISI 416 X12 CrS 13
16 Mechanical seal Carbon/ceramic
28 O-ring gasket FKM
283
4 16
1 7
48
PFPBasic Technical data
Operating conditionsOperating range: From 0.5 to 2.7 m3/h with heads up to 53 metres.
Pumped liquid: Clean, free from solids or abrasive substances, non-aggressive, noncrystallized, chemically neutral, similar to the characteristics of water.
Liquid temperature range: From –10°C to +80°C
Maximum ambient temperature: +40°C
Maximum operating pressure: 10 bar (1000 kPa)
Installation: Fixed in the horizontal position.
The performance curves are based on a kinematic viscosity value of 1 mm²/s and a density equal to 1000 kg/m3.
Curve tolerances according to ISO 9906, annex A.
Electrical data
Dimensions and weights
TM0
2 9
09
2 18
04
TM0
2 6
758
130
40.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Q [m³/h]
0
4
8
12
16
20
24
28
32
36
40
44
48
52
56[m]H
0
80
160
240
320
400
480
[kPa]p
0.0 0.2 0.4 0.6 0.8 Q [l/s]
PFPBasic 2-5050 Hz
ISO 9906 Annex A
Model Voltage [V]P1 max.
[kW]P2
[kW]P2
[hp]In
[A]Capacitor
µF Vc
PFPBasic 2-50 1 x 220-240 1.05 0.75 1 4.7 20 450
Model A B C E F G I H H1 H2 DNA DNMPacking dimensions [mm] Volume
[m3]Weight
[kg]L/A L/B L/H
PFPBasic 2-50 301 142 38 136 90 112 7 206 146 187 Rp 1 Rp 1 406 267 402 0.044 10.7
49
50
51
www.grundfos.com
Subject to alterations.
GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark Telephone: +45 87 50 14 00.
Being responsible is our foundationThinking ahead makes it possible