group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with...

10
PLAN FOUR FIRST FLOOR = 2034 SQ. FT. SECOND FLOOR = 1970 SQ. FT. TOTAL = 4004 SQ. FT. 3-BAY GARAGE = 869 SQ. FT. COVERED PORCH = 33 SQ. FT. LOT COVERAGE = 2945 SQ. FT. MAX. LOT COVERAGE = 3938 SQ. FT. OPT. OUTDOOR LIVING = +181 SQ. FT. - A SECOND FLOOR PLAN 'A' 1/4" = 1/-0" MODERN SPANISH DN D OPT. CABS OPEN TO BELOW MASTER BEDROOM 9'-0" CLG. CARPET MASTER BATH 9'-0" CLG. HS HER W.I.C. 9'-0" CLG. CARPET HIS W.I.C. 9'-0" CLG. CARPET OPT 2668 DR SEAT - 18"AFF 2480 S & P S & P S & P S & P S & P S & P OPTIONAL SINK/CABS STD. UPPERS LAU. 9'-0" CLG. HS 2480 2880 LOFT 9'-0" CLG. CARPET BEDROOM 3 9'-0" CLG. CARPET BEDROOM 2 9'-0" CLG. CARPET BEDROOM 4 9'-0" CLG. CARPET BATH 2 9'-0" CLG. HS S & P S & P BATH 3 9'-0" CLG. HS MC MC MC S & P OPT 2468 DR 2680 2480 2480 2680 2480 2680 4080 BP 4080 BP 5080 BP 2480 2680 2480 T T T T E E E E HALL 9'-0" CLG. CARPET B A4-A4-0 A A4-A4-0 B A4-A4-0 A A4-A4-0 60'-0" 50'-8 1 2 " 60'-0" 50'-2 1 2 " 7'-4 1 2 " 31'-11 1 2 " 10'-10 1 2 " 12'-1" 12'-10 1 2 " 13'-7 1 2 " 6'-0" 10'-1 1 2 " 5'-3 1 2 " 3'-1" 2'-0" 3'-6" 2'-0" 3'-0 1 2 " 3'-1" 2'-0" 2'-0" 3'-0 1 2 " 1'-0" 1'-0" 42'-4" 7'-4 1 2 " 8'-3 1 2 " 15'-2" 36'-6 1 2 " 1'-10 1 2 " 2'-3 1 2 " 4'-6 1 2 " 1'-11" 2040 SH 3050 SH 3050 SH 4018 FX 3050 SH 2650 SH 5050 FX 2650 SH 3050 FX 3050 FX 3050 FX 2050 SH 3050 SH 3050 SH 3050 SH 4040 SL 3050 SH 3050 SH 3050 SH 2040 SH 2040 SH 2040 SH 2040 SH 3050 SH LINE OF STONE VENEER 6" 6" 6" 30"X30" ATTIC ACCESS 4 10-01 AD 1 09-01 AD 11 09-01 AD FAU & PASSAGE WAY IN ATTIC. 5'X10' PLATFORM 3'-6" 6'-4" 8'-2 1 2 " 11'-4 1 2 " 5'-3 1 2 " 11'-1 1 2 " 4'-7" 2'-9 1 2 " 5'-5 1 2 " 5'-8" 2'-9 1 2 " 2'-6" 9'-1 1 2 " 2'-3" 1'-10" 4'-6" 12'-9" 2'-8" 16'-2" 4'-11 1 2 " 3'-4" 4'-3" 4'-3" 3'-4" 2'-3 1 2 " 2'-2 1 2 " 5'-10 1 2 " 8'-1" 2'-9 1 2 " 4'-7" 12'-11 1 2 " 18'-0" 1'-0" 9'-2" 8'-10" 6'-0 1 2 " 6'-0 1 2 " 8'-8 1 2 " 4'-2" 1'-0" 3'-11" 3'-6" 3'-11 1 2 " 7 1 2 " 8'-4 1 2 " 6'-2" 5'-0" 6'-10" 7" 5'-1 1 2 " 3'-3" 3'-6" 3'-6" 6" 8'-10" 3'-9 1 2 " 1'-8" 1'-8" 4'-0" 4'-10" 4'-0 1 2 " 5'-1" 1'-3 1 2 " 11'-4 1 2 " 1'-0" 17'-6" 3 1 2 " 3'-6" 11'-6 1 2 " 4'-4 1 2 " 4'-4" 11'-7 1 2 " 5'-6" 5'-2" 5'-3 1 2 " 3'-6" 3 1 2 " 11'-5" 10'-8" 3 1 2 " 5'-5" 2'-8" 11'-10 1 2 " 3'-0" 3'-0" 1'-4" 2'-1" 1'-4" 6'-3 1 2 " 3'-0" 1'-0" 19'-9" 32"x60" TUB/ SHWR. COMBO W/ ROD PER SPECS. TOWEL BAR TOWEL BAR 1'-7" 1'-6 1 2 " 32"x60" TUB/ SHWR. COMBO W/ ROD PER SPECS. 3 1 2 " 14'-10" LOW WALL (42" MIN.) 7 09-01 AD 2'-2" WASHER ALWAYS ON LEFT. PROVIDE RECESSED WATER, WASTE & SMITTY PAN 5 10-01 AD 5'-2" 36" CLR. MIN. WASHER ALWAYS ON LEFT 3'-4" T T 14 10-01 AD 36"x66" FREESTANDING OVAL TUB, PER SPECS SHOWER PER SPECS MECH. CHASE, TYP TOWEL BAR TOWEL BAR 6 10-01 AD 2 1 3 4 5 6 STRUCTURED WIRING BOX 7'-6" SOFFIT OPT. UPPERS 36"X60" SHOWER PAN 2480 LINEN 6'-2 1 2 " 2" 3'-11 1 2 " 9'-4" 2'-3 1 2 " MC THESE DESIGNS AND DRAWINGS ARE CONFIDENTIAL, AND THE EXCLUSIVE PROPERTY OF woodley architectural group,inc. AND ARE NOT TO BE DISCLOSED WITHOUT THE EXPRESS PERMISSION OF woodley architectural group,inc. THEY MAY NOT BE USED OR DUPLICATED WITHOUT THE EXPRESS PERMISSION OF woodley architectural group,inc. COPYRIGHT©2017 woodley architectural group,inc. ALL RIGHTS RESERVED. woodleyarchitecturalgroup,inc. colorado 2943 S. Pullman Street, Suite A Santa Ana, California 92705 V. 949.553.8919 F. 949.553.8909 california 731 SouthPark Dr., Suite B Littleton, Colorado 80120 V. 303.683.7231 F. 303.683.2922 PROJECT NO.: DRAWN BY: PLAN NUMBER SHEET NUMBER FIRST ISSUE: DATE: CORRECTIONS 08/13/2018 1 PLAN CHECK TWELVE BRIDGES TRAMONTE LINCOLN, CALIFORNIA WOODSIDE HOMES WDSCA-1702 MS 01/29/2019 07/06/2018 CORRECTIONS 2 PLANNING 08/13/2018 FRAMING WALK REVISIONS 3 CLIENT REVISIONS/ TBD A4-A2-2 FOUR 1. GLAZING SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH CRC SECTION R308.3 2. GLAZED PANELS REQUIRING SAFETY GLAZING SHALL BE IDENTIFIED WITH THE WORD 'TEMPERED' OR 'TEMP' OR GLAZING & FALL PROTECTION SAFETY GLAZING 1. ALL GLAZING SHALL COMPLY WITH CRC SECTION R308 2. ALL GLAZING SHALL BE DUAL PANE INSULATING GLASS U.N.O. IN THE TITLE 24 REPORT 3. WINDOW CALLOUTS ARE AS FOLLOWS: SL = SLIDER SH = SINGLE HUNG FG = FIXED GLASS CA = CASEMENT 1. WINDOW FALL PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITH SECTION R312.2.1 AND R312.2.2 2. IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED WINDOW FALL PROTECTION T 1. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE NOT LESS THAN ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING EMERGENCY EGRESS EMERGENCY ESCAPE AND RESCUE OPENINGS 1. NOTE: EXTERIOR WINDOWS LABELED W/ AN SYMBOL SHALL BE DESIGNATED FOR EMERGENCY EGRESS & RESCUE. 2. ESCAPE & RESCUE WINDOWS SHALL HAVE A MIN. NET CLEAR OPENABLE AREA OF 5.7 SQ. FT. THE MIN. NET CLEAR OPENING SHALL BE NOT LESS THAN 24 INCHES HIGH AND 20 INCHES WIDE. WHEN WINDOWS ARE PROVIDED AS A MEANS OF ESCAPE OR RESCUE, THEY SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES MEASURED FROM THE FLOOR. THESE WINDOWS 3. ANY BARS, GRILLS GRATES OR OTHER SIMILAR DEVICES SHALL BE OPERATIONAL FROM THE INSIDE OF ROOM WITHOUT THE USE OF KEYS OR TOOLS. E EMERGENCY ESCAPE AND RESCUE WINDOWS 1. NOTE: EXTERIOR DOORS LABELED W/ AN SYMBOL SHALL BE DESIGNATED FOR EMERGENCY EGRESS & RESCUE. 2. ESCAPE & RESCUE DOORS SHALL ARE PERMITTED TO BE SIDE HINGED OR A SLIDER. 3. THE MINIMUM NET CLEAR HEIGHT OPENING FOR ANY DOOR THAT SERVES AS AN EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE IN ACCORDANCE WITH SECTION R310.2.1 E EMERGENCY ESCAPE AND RESCUE DOORS BATH AND SHOWER SPACES 1. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. (SEC R307.2) 2. ALL GLASS SHOWER AND TUB/SHOWER DOORS SHALL BE TEMPERED. 3. SHOWER AND TUB/SHOWER COMBINATIONS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, OR COMBINATION PRESSURE BALANCE/THERMOSTATIC MIXING VALVE TYPE THAT PROVIDE SCALD AND THERMAL SHOCK PROTECTION. VALVES SHALL BE ADJUSTED PER THE MANUFACTURER'S INSTRUCTIONS TO DELIVER A MAXIMUM MIXED WATER SETTING OF 120 DEGREES FAHRENHEIT. 4. PROVIDE 15" MINIMUM BETWEEN THE CENTER OF THE WATER CLOSET TO ANY SIDE WALL 5. PROVIDE 24" CLEAR SPACE IN FRONT OF ANY WATER CLOSET 6. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED NATURAL VENTILATION OR WITH MECHANICAL VENTILATION CAPABLE OF 50 CFM EXHAUSTED DIRECTLY TO THE OUTSIDE (C.R.C. R303.3) LAUNDRY ROOM NOTES 1. UNLESS OTHERWISE PERMITTED OR REQUIRED BY THE DRYER MANUFACTURER'S INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION, DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET, INCLUDING TWO 90 DEGREE ELBOWS. A LENGTH OF 2 FEET SHALL BE DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO 2. PROVIDE 100 SQUARE INCHES OF MAKE-UP AIR TO ALL LAUNDRY ROOMS 3. WASHER SPACE, PROVIDE RECESSED WATER AND WASTE 4. AT 2ND FLOOR, PROVIDE "SMITTY" PAN UNDER WASHER WITH DRAIN TO OUTSIDE SOFFIT SYMBOLS FLAT SOFFIT W/ TOP @ 9'-0" A.F.F. @ 10'-0" PL., @ 8'-0" A.F.F. @ 9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESS OTHERWISE NOTED FLATTENED ARCH SOFFIT W/ TOP @ 9'-0" A.F.F. & SPRING POINT @ 8'-0" A.F.F. @ 10'-0" PL., TOP @ 8'-0" A.F.F & SPRING POINT @ 7'-0" A.F.F. @ 9'-0" PLATE OR TOP @ 7'-6" A.F.F & SPRING POINT @ 6'-6" A.F.F. @ 8'-0" PLATE UNLESS OTHERWISE NOTED WALL LEGEND 2X4 WALL 2X6 WALL 2X LOW WALL - HEIGHT PER FLOOR PLAN FULL ARCH SOFFIT W/ TOP OF ARCH @ 9'-0" A.F.F. @ 10'-0" PL., 8'-0" A.F.F. @ 9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESS OTHERWISE NOTED ELLIPTICAL ARCH SOFFIT AS NOTED IN PLAN OR ELEVATION 3 3

Transcript of group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with...

Page 1: group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with nonabsorbent surface. such wall surfaces shall extend to a height of not less than 6

PLAN FOURFIRST FLOOR = 2034 SQ. FT.

SECOND FLOOR = 1970 SQ. FT.

TOTAL = 4004 SQ. FT.

3-BAY GARAGE = 869 SQ. FT.

COVERED PORCH = 33 SQ. FT.

LOT COVERAGE = 2945 SQ. FT.

MAX. LOT COVERAGE = 3938 SQ. FT.

OPT. OUTDOOR LIVING = +181 SQ. FT.

- A

SECOND FLOOR PLAN 'A'1/4" = 1/-0" MODERN SPANISH

DN

90°

D

90°

90°

90°

90°

90°

90°

90°

90°

90°

90°

90°

OPT. CABS

90°

OPEN TOBELOW

MASTERBEDROOM

9'-0" CLG.CARPET

MASTERBATH9'-0" CLG.

HS

HERW.I.C.9'-0" CLG.CARPET

HISW.I.C.9'-0" CLG.CARPET

90°

OPT

2668

DR

SEA

T - 1

8"A

FF

2480

S & P

S &

P

S &

P

S &

P

S & P

S & P

OPTIONALSINK/CABS

STD

.UP

PERS

LAU.9'-0" CLG.

HS

2480

2880

LOFT9'-0" CLG.CARPET

BEDROOM 39'-0" CLG.CARPET

BEDROOM 29'-0" CLG.CARPET

BEDROOM 49'-0" CLG.CARPET

BATH 29'-0" CLG.

HS

S & P

S & P

BATH 39'-0" CLG.

HS

MC

MC

MC

S &

P

OPT

2468

DR

2680

2480

2480

2680

24802680

4080 BP

4080 BP

5080

BP

2480

2680

2480

T

T

T

T

E

E

E

E

HALL9'-0" CLG.CARPET

BA4-A4-0

AA4-A4-0

BA4-A4-0

AA4-A4-0

60'-0"

50'-8

1 2"

60'-0"

50'-2

1 2"

7'-4

1 2"31

'-111 2"

10'-1

01 2"

12'-1" 12'-1012" 13'-71

2" 6'-0"10'-11

2"5'-31

2"

3'-1" 2'-0" 3'-6" 2'-0" 3'-012" 3'-1" 2'-0" 2'-0" 3'-01

2"

1'-0

"

1'-0

"42

'-4"

7'-4

1 2"

8'-312" 15'-2" 36'-61

2"

1'-1012" 2'-31

2"4'-61

2" 1'-11"

2040SH

3050SH

3050SH

4018FX

3050SH

2650

SH5050

FX2650

SH

3050

FX 3050

FX 3050

FX 2050

SH

3050SH

3050SH

3050SH

4040SL

3050 SH

3050 SH

3050 SH 20

40 SH

2040 SH

2040

SH

2040 SH

3050 SH

LINE OFSTONEVENEER

6"6"

6"

30"X30"ATTICACCESS

410-01AD

109-01AD

1109-01AD

FAU & PASSAGEWAY IN ATTIC.5'X10' PLATFORM

3'-6

"

6'-4

"8'

-21 2"

11'-4

1 2"5'

-31 2"

11'-1

1 2"4'

-7"

2'-9

1 2"

5'-5

1 2"5'

-8"

2'-9

1 2"2'

-6"

9'-1

1 2"2'

-3"

1'-1

0"4'

-6"

12'-9"2'-8"16'-2"4'-1112"3'-4"4'-3"4'-3"3'-4"

2'-312"2'-21

2"5'-1012"8'-1"

2'-9

1 2"4'

-7"

12'-1

11 2"18

'-0"

1'-0

"

9'-2

"8'

-10"

6'-012" 6'-01

2"

8'-812"4'-2"

1'-0

"3'

-11"

3'-6

"3'

-111 2"

712"8'-41

2"6'-2

"5'

-0"

6'-1

0"

7"

5'-112" 3'-3" 3'-6"

3'-6" 6" 8'-10" 3'-912"

1'-8"

1'-8

"

4'-0

"

4'-1

0"4'

-01 2"

5'-1

"1'

-31 2"

11'-4

1 2"1'

-0"

17'-6

"31 2"

3'-6" 11'-612"

4'-412" 4'-4" 11'-71

2"

5'-6" 5'-2" 5'-312"

3'-6"312"

11'-5

"10

'-8"

31 2"5'

-5"

2'-8

"11

'-101 2"

3'-0" 3'-0"

1'-4

"

2'-1"

1'-4

"6'

-31 2"

3'-0" 1'-0"

19'-9

"

32"x60" TUB/SHWR. COMBOW/ ROD PERSPECS.

TOW

EL B

AR

TOW

EL B

AR

1'-7

"

1'-612"

32"x60" TUB/ SHWR.COMBO W/ ROD PERSPECS.

312"14'-10"

LOW WALL(42" MIN.)

709-01AD

2'-2"

WASHER ALWAYSON LEFT.PROVIDERECESSEDWATER, WASTE &SMITTY PAN

510-01AD

5'-2"

36" CLR. MIN.WASHERALWAYSON LEFT

3'-4

"

T T

1410-01AD

36"x66"FREESTANDINGOVAL TUB,PER SPECS

SHOWERPER SPECS

MECH. CHASE,TYP

TOW

EL B

AR

TOWEL BAR

610-01AD

2

1 3

4

5

6

STRUCTUREDWIRINGBOX

7'-6"SOFFIT

OPT.UPPERS

36"X

60" S

HOW

ER P

AN

15°

2480

LIN

EN

6'-212"2"

3'-1

11 2"

9'-4"2'-312"

MC

THES

E DE

SIG

NS

AN

D DR

AW

ING

S A

RE C

ON

FIDE

NTIA

L, A

ND

THE

EXC

LUSI

VE P

ROPE

RTY

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

AN

D A

RE N

OT T

O B

E DI

SCLO

SED

WITH

OUT

THE

EXPR

ESS

PERM

ISSI

ON

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

THE

Y M

AY

NO

T BE

USED

OR

DUP

LIC

ATE

D W

ITHO

UT TH

E EX

PRES

S PE

RMIS

SIO

N O

F w

ood

ley

arch

itect

ural

grou

p,in

c. C

OPY

RIG

HT©

2017

w

ood

ley

arch

itect

ural

grou

p,in

c. A

LL R

IGHT

S RE

SERV

ED.

woo

dle

yarc

hite

ctur

algr

oup,

inc.

c o l o r a d o

2943 S. Pullman Street, Suite ASanta Ana, California 92705

V. 949.553.8919 F. 949.553.8909

ca l i fo rn ia

731 SouthPark Dr., Suite BLittleton, Colorado 80120

V. 303.683.7231 F. 303.683.2922

PROJECT NO.:DRAWN BY:

PLAN NUMBER

SHEET NUMBER

FIRST ISSUE:DATE:

CORRECTIONS 08/13/20181 PLAN CHECK

TWEL

VE

BRID

GES

TRA

MO

NTE

LIN

CO

LN,

CA

LIFO

RNIA

WO

OD

SID

E HO

MES

WDSCA-1702

MS

01/29/2019

07/06/2018

CORRECTIONS2 PLANNING08/13/2018

FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD

A4-A2-2

FOUR

1. GLAZING SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH CRC SECTION R308.32. GLAZED PANELS REQUIRING SAFETY GLAZING SHALL BE IDENTIFIED WITH THE

WORD 'TEMPERED' OR 'TEMP' OR

GLAZING & FALL PROTECTION

SAFETY GLAZING

1. ALL GLAZING SHALL COMPLY WITH CRC SECTION R3082. ALL GLAZING SHALL BE DUAL PANE INSULATING GLASS U.N.O. IN THE TITLE 24

REPORT3. WINDOW CALLOUTS ARE AS FOLLOWS:

SL = SLIDER SH = SINGLE HUNGFG = FIXED GLASS CA = CASEMENT

1. WINDOW FALL PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITHSECTION R312.2.1 AND R312.2.2

2. IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW ISLOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR SURFACEBELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE AMINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICHTHE WINDOW IS LOCATED

WINDOW FALL PROTECTION

T

1. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE NOTLESS THAN ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING

EMERGENCY EGRESSEMERGENCY ESCAPE AND RESCUE OPENINGS

1. NOTE: EXTERIOR WINDOWS LABELED W/ AN SYMBOL SHALL BE DESIGNATEDFOR EMERGENCY EGRESS & RESCUE.

2. ESCAPE & RESCUE WINDOWS SHALL HAVE A MIN. NET CLEAR OPENABLE AREA OF5.7 SQ. FT. THE MIN. NET CLEAR OPENING SHALL BE NOT LESS THAN 24 INCHESHIGH AND 20 INCHES WIDE. WHEN WINDOWS ARE PROVIDED AS A MEANS OFESCAPE OR RESCUE, THEY SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOTGREATER THAN 44 INCHES MEASURED FROM THE FLOOR. THESE WINDOWS

3. ANY BARS, GRILLS GRATES OR OTHER SIMILAR DEVICES SHALL BE OPERATIONALFROM THE INSIDE OF ROOM WITHOUT THE USE OF KEYS OR TOOLS.

EEMERGENCY ESCAPE AND RESCUE WINDOWS

1. NOTE: EXTERIOR DOORS LABELED W/ AN SYMBOL SHALL BE DESIGNATED FOREMERGENCY EGRESS & RESCUE.

2. ESCAPE & RESCUE DOORS SHALL ARE PERMITTED TO BE SIDE HINGED OR A SLIDER.3. THE MINIMUM NET CLEAR HEIGHT OPENING FOR ANY DOOR THAT SERVES AS AN

EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE IN ACCORDANCE WITHSECTION R310.2.1

EEMERGENCY ESCAPE AND RESCUE DOORS

BATH AND SHOWER SPACES1. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED

SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITHNONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHTOF NOT LESS THAN 6 FEET ABOVE THE FLOOR. (SEC R307.2)

2. ALL GLASS SHOWER AND TUB/SHOWER DOORS SHALL BE TEMPERED.3. SHOWER AND TUB/SHOWER COMBINATIONS SHALL BE PROVIDED WITH

INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, ORCOMBINATION PRESSURE BALANCE/THERMOSTATIC MIXING VALVE TYPE THATPROVIDE SCALD AND THERMAL SHOCK PROTECTION. VALVES SHALL BEADJUSTED PER THE MANUFACTURER'S INSTRUCTIONS TO DELIVER A MAXIMUMMIXED WATER SETTING OF 120 DEGREES FAHRENHEIT.

4. PROVIDE 15" MINIMUM BETWEEN THE CENTER OF THE WATER CLOSET TO ANYSIDE WALL

5. PROVIDE 24" CLEAR SPACE IN FRONT OF ANY WATER CLOSET6. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS

SHALL BE PROVIDED NATURAL VENTILATION OR WITH MECHANICAL VENTILATIONCAPABLE OF 50 CFM EXHAUSTED DIRECTLY TO THE OUTSIDE (C.R.C. R303.3)

LAUNDRY ROOM NOTES1. UNLESS OTHERWISE PERMITTED OR REQUIRED BY THE DRYER MANUFACTURER'S

INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION,DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTALCOMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET, INCLUDING TWO 90DEGREE ELBOWS. A LENGTH OF 2 FEET SHALL BE DEDUCTED FOR EACH 90 DEGREEELBOW IN EXCESS OF TWO

2. PROVIDE 100 SQUARE INCHES OF MAKE-UP AIR TO ALL LAUNDRY ROOMS3. WASHER SPACE, PROVIDE RECESSED WATER AND WASTE4. AT 2ND FLOOR, PROVIDE "SMITTY" PAN UNDER WASHER WITH DRAIN TO OUTSIDE

SOFFIT SYMBOLSFLAT SOFFIT W/ TOP @ 9'-0" A.F.F. @ 10'-0" PL., @ 8'-0" A.F.F. @9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESS OTHERWISE NOTED

FLATTENED ARCH SOFFIT W/ TOP @ 9'-0" A.F.F. & SPRING POINT@ 8'-0" A.F.F. @ 10'-0" PL., TOP @ 8'-0" A.F.F & SPRING POINT @7'-0" A.F.F. @ 9'-0" PLATE OR TOP @ 7'-6" A.F.F & SPRING POINT@ 6'-6" A.F.F. @ 8'-0" PLATE UNLESS OTHERWISE NOTED

WALL LEGEND2X4 WALL

2X6 WALL

2X LOW WALL - HEIGHTPER FLOOR PLAN

FULL ARCH SOFFIT W/ TOP OF ARCH @ 9'-0" A.F.F. @ 10'-0" PL.,8'-0" A.F.F. @ 9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESSOTHERWISE NOTED

ELLIPTICAL ARCH SOFFIT AS NOTED IN PLAN OR ELEVATION

3

3

Page 2: group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with nonabsorbent surface. such wall surfaces shall extend to a height of not less than 6

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

LEFT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

3'-0

"

312

412

WINDOW AT OPT.HOME-PLUS

412

412

1201-01AD

902-01AD

ATWALL

1303-01AD

103-01AD

603-01AD

1204-01AD

504-01AD

1004-01AD

4" CASTSTONE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

RIGHT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

1'-0"

EQ. EQ.

3'-0

"

412 4

12

1101-01AD

701-01AD

2" CASTSTONE

1002-01AD

2x6 BARGERAFTER,

TYP.

502-01AD

TYP.

105-01AD

1105-01AD

605-01AD

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

PARTIALLEFT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH

OPT. CENTER MEET SLIDER502-01AD

TYP.

PARTIALRIGHT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

312

1002-01AD

2x6 BARGERAFTER,TYP.

THES

E DE

SIG

NS

AN

D DR

AW

ING

S A

RE C

ON

FIDE

NTIA

L, A

ND

THE

EXC

LUSI

VE P

ROPE

RTY

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

AN

D A

RE N

OT T

O B

E DI

SCLO

SED

WITH

OUT

THE

EXPR

ESS

PERM

ISSI

ON

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

THE

Y M

AY

NO

T BE

USED

OR

DUP

LIC

ATE

D W

ITHO

UT TH

E EX

PRES

S PE

RMIS

SIO

N O

F w

ood

ley

arch

itect

ural

grou

p,in

c. C

OPY

RIG

HT©

2017

w

ood

ley

arch

itect

ural

grou

p,in

c. A

LL R

IGHT

S RE

SERV

ED.

woo

dle

yarc

hite

ctur

algr

oup,

inc.

c o l o r a d o

2943 S. Pullman Street, Suite ASanta Ana, California 92705

V. 949.553.8919 F. 949.553.8909

ca l i fo rn ia

731 SouthPark Dr., Suite BLittleton, Colorado 80120

V. 303.683.7231 F. 303.683.2922

PROJECT NO.:DRAWN BY:

PLAN NUMBER

SHEET NUMBER

FIRST ISSUE:DATE:

CORRECTIONS 08/13/20181 PLAN CHECK

TWEL

VE

BRID

GES

TRA

MO

NTE

LIN

CO

LN,

CA

LIFO

RNIA

WO

OD

SID

E HO

MES

WDSCA-1702

MS

01/29/2019

07/06/2018

CORRECTIONS2 PLANNING08/13/2018

FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD

A4-A5-1

FOUR

2

3

Page 3: group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with nonabsorbent surface. such wall surfaces shall extend to a height of not less than 6

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

LEFT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

3'-0

"

312

412

WINDOW AT OPT.HOME-PLUS

412

412

- ENHANCED

ADHERED STONEVENEER

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

RIGHT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

1'-0"

EQ. EQ.

3'-0

"

412 4

12

- ENHANCED

3'-0"

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

PARTIALLEFT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH

OPT. CENTER MEET SLIDER

- ENHANCED

7'-0

"

205-01AD

705-01AD

403-01AD

903-01AD

PARTIALRIGHT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

312

- ENHANCED

THES

E DE

SIG

NS

AN

D DR

AW

ING

S A

RE C

ON

FIDE

NTIA

L, A

ND

THE

EXC

LUSI

VE P

ROPE

RTY

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

AN

D A

RE N

OT T

O B

E DI

SCLO

SED

WITH

OUT

THE

EXPR

ESS

PERM

ISSI

ON

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

THE

Y M

AY

NO

T BE

USED

OR

DUP

LIC

ATE

D W

ITHO

UT TH

E EX

PRES

S PE

RMIS

SIO

N O

F w

ood

ley

arch

itect

ural

grou

p,in

c. C

OPY

RIG

HT©

2017

w

ood

ley

arch

itect

ural

grou

p,in

c. A

LL R

IGHT

S RE

SERV

ED.

woo

dle

yarc

hite

ctur

algr

oup,

inc.

c o l o r a d o

2943 S. Pullman Street, Suite ASanta Ana, California 92705

V. 949.553.8919 F. 949.553.8909

ca l i fo rn ia

731 SouthPark Dr., Suite BLittleton, Colorado 80120

V. 303.683.7231 F. 303.683.2922

PROJECT NO.:DRAWN BY:

PLAN NUMBER

SHEET NUMBER

FIRST ISSUE:DATE:

CORRECTIONS 08/13/20181 PLAN CHECK

TWEL

VE

BRID

GES

TRA

MO

NTE

LIN

CO

LN,

CA

LIFO

RNIA

WO

OD

SID

E HO

MES

WDSCA-1702

MS

01/29/2019

07/06/2018

CORRECTIONS2 PLANNING08/13/2018

FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD

A4-A5-1E

FOUR

Page 4: group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with nonabsorbent surface. such wall surfaces shall extend to a height of not less than 6

90°

90°

90°

90°

90°

90°

90°

90°

90°

90°

90°

90°

OPT. CABS

90°

MASTERBEDROOM

9'-0" CLG.CARPET

MASTERBATH9'-0" CLG.

HS

HERW.I.C.9'-0" CLG.CARPET

HISW.I.C.9'-0" CLG.CARPET

90°

OPT

2668

DR

OPTIONALSINK/CABS

LAU.9'-0" CLG.

HS

LOFT9'-0" CLG.CARPET

BEDROOM 39'-0" CLG.CARPET

BEDROOM 29'-0" CLG.CARPET

BEDROOM 49'-0" CLG.CARPET

BATH 29'-0" CLG.

HS

BATH 39'-0" CLG.

HS

OPT

2468

DR

E

E

E

HALL9'-0" CLG.CARPETOPT.

UPPERS

15°

SEE STANDARD PLAN FORINFORMATION NOT SHOWNHERE.SECOND FLOOR PLAN 'B'

1/4" = 1/-0" MID-CENTURY MODERN

5'-312"10'-11

2"6'-0"13'-712"12'-101

2"12'-1"

2'-612"5'-0"2'-7"3'-0"3'-0"3'-01

2"7'-6"3'-1"

2'-6"2'-6"2'-0"3'-6"2'-0"

2'-312" 7'-6" 2'-31

2"

3'-6" 2'-0"

1'-0

"18

'-0"

1'-0

"

11'-1

01 2"

3'-1

1"3'

-6"

4'-5

1 2"

6" 6" 6"6'

-01 2"

E

4050 SL

4050

SL

4020

FX

BELO

W

T3050 SH

3050 SH

2'-0"

3050 SH

3050 SH

3040SH

3040SH

SEE BASE PLAN A FORINFORMATION ONAREA WITHIN HATCH

PLAN FOURFIRST FLOOR = 2034 SQ. FT.

SECOND FLOOR = 1970 SQ. FT.

TOTAL = 4004 SQ. FT.

3-BAY GARAGE = 869 SQ. FT.

COVERED PORCH =

LOT COVERAGE =

MAX. LOT COVERAGE = 3938 SQ. FT.

OPT. OUTDOOR LIVING = +181 SQ. FT.

63 SQ. FT.

- B

2981 SQ. FT.

THES

E DE

SIG

NS

AN

D DR

AW

ING

S A

RE C

ON

FIDE

NTIA

L, A

ND

THE

EXC

LUSI

VE P

ROPE

RTY

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

AN

D A

RE N

OT T

O B

E DI

SCLO

SED

WITH

OUT

THE

EXPR

ESS

PERM

ISSI

ON

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

THE

Y M

AY

NO

T BE

USED

OR

DUP

LIC

ATE

D W

ITHO

UT TH

E EX

PRES

S PE

RMIS

SIO

N O

F w

ood

ley

arch

itect

ural

grou

p,in

c. C

OPY

RIG

HT©

2017

w

ood

ley

arch

itect

ural

grou

p,in

c. A

LL R

IGHT

S RE

SERV

ED.

woo

dle

yarc

hite

ctur

algr

oup,

inc.

c o l o r a d o

2943 S. Pullman Street, Suite ASanta Ana, California 92705

V. 949.553.8919 F. 949.553.8909

ca l i fo rn ia

731 SouthPark Dr., Suite BLittleton, Colorado 80120

V. 303.683.7231 F. 303.683.2922

PROJECT NO.:DRAWN BY:

PLAN NUMBER

SHEET NUMBER

FIRST ISSUE:DATE:

CORRECTIONS 08/13/20181 PLAN CHECK

TWEL

VE

BRID

GES

TRA

MO

NTE

LIN

CO

LN,

CA

LIFO

RNIA

WO

OD

SID

E HO

MES

WDSCA-1702

MS

01/29/2019

07/06/2018

CORRECTIONS2 PLANNING08/13/2018

FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD

A4-B2-2

FOUR

1. GLAZING SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH CRC SECTION R308.32. GLAZED PANELS REQUIRING SAFETY GLAZING SHALL BE IDENTIFIED WITH THE

WORD 'TEMPERED' OR 'TEMP' OR

GLAZING & FALL PROTECTION

SAFETY GLAZING

1. ALL GLAZING SHALL COMPLY WITH CRC SECTION R3082. ALL GLAZING SHALL BE DUAL PANE INSULATING GLASS U.N.O. IN THE TITLE 24

REPORT3. WINDOW CALLOUTS ARE AS FOLLOWS:

SL = SLIDER SH = SINGLE HUNGFG = FIXED GLASS CA = CASEMENT

1. WINDOW FALL PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITHSECTION R312.2.1 AND R312.2.2

2. IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW ISLOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR SURFACEBELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE AMINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICHTHE WINDOW IS LOCATED

WINDOW FALL PROTECTION

T

1. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE NOTLESS THAN ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING

EMERGENCY EGRESSEMERGENCY ESCAPE AND RESCUE OPENINGS

1. NOTE: EXTERIOR WINDOWS LABELED W/ AN SYMBOL SHALL BE DESIGNATEDFOR EMERGENCY EGRESS & RESCUE.

2. ESCAPE & RESCUE WINDOWS SHALL HAVE A MIN. NET CLEAR OPENABLE AREA OF5.7 SQ. FT. THE MIN. NET CLEAR OPENING SHALL BE NOT LESS THAN 24 INCHESHIGH AND 20 INCHES WIDE. WHEN WINDOWS ARE PROVIDED AS A MEANS OFESCAPE OR RESCUE, THEY SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOTGREATER THAN 44 INCHES MEASURED FROM THE FLOOR. THESE WINDOWS

3. ANY BARS, GRILLS GRATES OR OTHER SIMILAR DEVICES SHALL BE OPERATIONALFROM THE INSIDE OF ROOM WITHOUT THE USE OF KEYS OR TOOLS.

EEMERGENCY ESCAPE AND RESCUE WINDOWS

1. NOTE: EXTERIOR DOORS LABELED W/ AN SYMBOL SHALL BE DESIGNATED FOREMERGENCY EGRESS & RESCUE.

2. ESCAPE & RESCUE DOORS SHALL ARE PERMITTED TO BE SIDE HINGED OR A SLIDER.3. THE MINIMUM NET CLEAR HEIGHT OPENING FOR ANY DOOR THAT SERVES AS AN

EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE IN ACCORDANCE WITHSECTION R310.2.1

EEMERGENCY ESCAPE AND RESCUE DOORS

BATH AND SHOWER SPACES1. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED

SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITHNONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHTOF NOT LESS THAN 6 FEET ABOVE THE FLOOR. (SEC R307.2)

2. ALL GLASS SHOWER AND TUB/SHOWER DOORS SHALL BE TEMPERED.3. SHOWER AND TUB/SHOWER COMBINATIONS SHALL BE PROVIDED WITH

INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, ORCOMBINATION PRESSURE BALANCE/THERMOSTATIC MIXING VALVE TYPE THATPROVIDE SCALD AND THERMAL SHOCK PROTECTION. VALVES SHALL BEADJUSTED PER THE MANUFACTURER'S INSTRUCTIONS TO DELIVER A MAXIMUMMIXED WATER SETTING OF 120 DEGREES FAHRENHEIT.

4. PROVIDE 15" MINIMUM BETWEEN THE CENTER OF THE WATER CLOSET TO ANYSIDE WALL

5. PROVIDE 24" CLEAR SPACE IN FRONT OF ANY WATER CLOSET6. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS

SHALL BE PROVIDED NATURAL VENTILATION OR WITH MECHANICAL VENTILATIONCAPABLE OF 50 CFM EXHAUSTED DIRECTLY TO THE OUTSIDE (C.R.C. R303.3)

LAUNDRY ROOM NOTES1. UNLESS OTHERWISE PERMITTED OR REQUIRED BY THE DRYER MANUFACTURER'S

INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION,DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTALCOMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET, INCLUDING TWO 90DEGREE ELBOWS. A LENGTH OF 2 FEET SHALL BE DEDUCTED FOR EACH 90 DEGREEELBOW IN EXCESS OF TWO

2. PROVIDE 100 SQUARE INCHES OF MAKE-UP AIR TO ALL LAUNDRY ROOMS3. WASHER SPACE, PROVIDE RECESSED WATER AND WASTE4. AT 2ND FLOOR, PROVIDE "SMITTY" PAN UNDER WASHER WITH DRAIN TO OUTSIDE

SOFFIT SYMBOLSFLAT SOFFIT W/ TOP @ 9'-0" A.F.F. @ 10'-0" PL., @ 8'-0" A.F.F. @9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESS OTHERWISE NOTED

FLATTENED ARCH SOFFIT W/ TOP @ 9'-0" A.F.F. & SPRING POINT@ 8'-0" A.F.F. @ 10'-0" PL., TOP @ 8'-0" A.F.F & SPRING POINT @7'-0" A.F.F. @ 9'-0" PLATE OR TOP @ 7'-6" A.F.F & SPRING POINT@ 6'-6" A.F.F. @ 8'-0" PLATE UNLESS OTHERWISE NOTED

WALL LEGEND2X4 WALL

2X6 WALL

2X LOW WALL - HEIGHTPER FLOOR PLAN

FULL ARCH SOFFIT W/ TOP OF ARCH @ 9'-0" A.F.F. @ 10'-0" PL.,8'-0" A.F.F. @ 9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESSOTHERWISE NOTED

ELLIPTICAL ARCH SOFFIT AS NOTED IN PLAN OR ELEVATION

Page 5: group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with nonabsorbent surface. such wall surfaces shall extend to a height of not less than 6

LEFT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

312

412

WINDOW AT OPT.HOME-PLUS

412 4

12

902-02AD

2x6 BARGERAFTER,

TYP.

802-02AD

ATWALL

1303-01AD

103-01AD

603-01AD

204-01AD

1X4TRIM

704-01AD

1204-01AD

205-01AD

705-01AD

1205-01AD

RIGHT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

1'-0"

6'-2"

1'-0"

412 4

12

1101-01AD

1301-01AD

402-02AD TYP.

105-01AD

1105-01AD

605-01AD

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

PARTIALLEFT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN

OPT. CENTER MEET SLIDER 402-02AD TYP.

PARTIALRIGHT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

312

902-02AD

2x6 BARGERAFTER,TYP.

THES

E DE

SIG

NS

AN

D DR

AW

ING

S A

RE C

ON

FIDE

NTIA

L, A

ND

THE

EXC

LUSI

VE P

ROPE

RTY

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

AN

D A

RE N

OT T

O B

E DI

SCLO

SED

WITH

OUT

THE

EXPR

ESS

PERM

ISSI

ON

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

THE

Y M

AY

NO

T BE

USED

OR

DUP

LIC

ATE

D W

ITHO

UT TH

E EX

PRES

S PE

RMIS

SIO

N O

F w

ood

ley

arch

itect

ural

grou

p,in

c. C

OPY

RIG

HT©

2017

w

ood

ley

arch

itect

ural

grou

p,in

c. A

LL R

IGHT

S RE

SERV

ED.

woo

dle

yarc

hite

ctur

algr

oup,

inc.

c o l o r a d o

2943 S. Pullman Street, Suite ASanta Ana, California 92705

V. 949.553.8919 F. 949.553.8909

ca l i fo rn ia

731 SouthPark Dr., Suite BLittleton, Colorado 80120

V. 303.683.7231 F. 303.683.2922

PROJECT NO.:DRAWN BY:

PLAN NUMBER

SHEET NUMBER

FIRST ISSUE:DATE:

CORRECTIONS 08/13/20181 PLAN CHECK

TWEL

VE

BRID

GES

TRA

MO

NTE

LIN

CO

LN,

CA

LIFO

RNIA

WO

OD

SID

E HO

MES

WDSCA-1702

MS

01/29/2019

07/06/2018

CORRECTIONS2 PLANNING08/13/2018

FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD

A4-B5-1

FOUR

3

Page 6: group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with nonabsorbent surface. such wall surfaces shall extend to a height of not less than 6

LEFT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

312

412

WINDOW AT OPT.HOME-PLUS

412 4

12

- ENHANCED

205-01AD

705-01AD

1205-01AD

24"X

48"

24"X

48"

303-01AD

803-01AD

RIGHT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

1'-0"

6'-2"

1'-0"

412 4

12

- ENHANCED

205-01AD

705-01AD

1205-01AD

18"X

60"

18"X

60"

18"X

60"

18"X

60"

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

PARTIALLEFT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN

OPT. CENTER MEET SLIDER

- ENHANCED

403-01AD

903-01AD

205-01AD

705-01AD

1205-01AD

PARTIALRIGHT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

312

- ENHANCED

THES

E DE

SIG

NS

AN

D DR

AW

ING

S A

RE C

ON

FIDE

NTIA

L, A

ND

THE

EXC

LUSI

VE P

ROPE

RTY

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

AN

D A

RE N

OT T

O B

E DI

SCLO

SED

WITH

OUT

THE

EXPR

ESS

PERM

ISSI

ON

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

THE

Y M

AY

NO

T BE

USED

OR

DUP

LIC

ATE

D W

ITHO

UT TH

E EX

PRES

S PE

RMIS

SIO

N O

F w

ood

ley

arch

itect

ural

grou

p,in

c. C

OPY

RIG

HT©

2017

w

ood

ley

arch

itect

ural

grou

p,in

c. A

LL R

IGHT

S RE

SERV

ED.

woo

dle

yarc

hite

ctur

algr

oup,

inc.

c o l o r a d o

2943 S. Pullman Street, Suite ASanta Ana, California 92705

V. 949.553.8919 F. 949.553.8909

ca l i fo rn ia

731 SouthPark Dr., Suite BLittleton, Colorado 80120

V. 303.683.7231 F. 303.683.2922

PROJECT NO.:DRAWN BY:

PLAN NUMBER

SHEET NUMBER

FIRST ISSUE:DATE:

CORRECTIONS 08/13/20181 PLAN CHECK

TWEL

VE

BRID

GES

TRA

MO

NTE

LIN

CO

LN,

CA

LIFO

RNIA

WO

OD

SID

E HO

MES

WDSCA-1702

MS

01/29/2019

07/06/2018

CORRECTIONS2 PLANNING08/13/2018

FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD

A4-B5-1E

FOUR

Page 7: group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with nonabsorbent surface. such wall surfaces shall extend to a height of not less than 6

90°

90°

90°

90°

90°

90°

90°

90°

90°

90°

90°

90°

OPT. CABS

90°

MASTERBEDROOM

9'-0" CLG.CARPET

MASTERBATH9'-0" CLG.

HS

HERW.I.C.9'-0" CLG.CARPET

HISW.I.C.9'-0" CLG.CARPET

90°

OPT

2668

DR

OPTIONALSINK/CABS

LAU.9'-0" CLG.

HS

LOFT9'-0" CLG.CARPET

BEDROOM 39'-0" CLG.CARPET

BEDROOM 29'-0" CLG.CARPET

BEDROOM 49'-0" CLG.CARPET

BATH 29'-0" CLG.

HS

BATH 39'-0" CLG.

HS

OPT

2468

DR

E

E

E

HALL9'-0" CLG.CARPETOPT.

UPPERS

15°

SEE STANDARD PLAN FORINFORMATION NOT SHOWNHERE.SECOND FLOOR PLAN 'C'

1/4" = 1/-0" MODERN PRAIRIE

3050 SH

3050 SH

2020 FX

2020 FX

2020 FX

2050 SH

2050 SH

2050 SH

EQ. HEAD/JAMB/ SILL

EQ. HEAD/JAMB/ SILL EQ. HEAD/

JAMB/ SILL

LINE OFSTONEVENEER

6'-512"9'-6"5'-51

2"13'-712"12'-101

2"12'-1"

11'-1

01 2"

1'-1012" 4'-61

2" 1'-11"

2'-0

"3'

-6"

3050SH

3050SH

3'-612"2'-6"2'-6"3'-61

2"

1'-0

"

1'-0

"18

'-0"

2'-0" 3'-6" 8'-112" 1'-101

2" 2'-612" 1'-01

2"2'-6" 4'-6" 2'-6"

6" 6"

1'-0

"6'

-01 2"

312"

6"

312"

SEE BASE PLAN A FORINFORMATION ONAREA WITHIN HATCH

E

4050 SL

4050 SL

1650

FX

1620

FX

BELO

W

T

3050

FX

3020

FX

BELO

W

T

4'-612"

PLAN FOURFIRST FLOOR =SECOND FLOOR =TOTAL =

3-BAY GARAGE = 869 SQ. FT.

COVERED PORCH =

LOT COVERAGE =

MAX. LOT COVERAGE = 3938 SQ. FT.

OPT. OUTDOOR LIVING = +181 SQ. FT.

30 SQ. FT.

- C

2961 SQ. FT.

2048 SQ. FT.

1969 SQ. FT.

4017 SQ. FT.

THES

E DE

SIG

NS

AN

D DR

AW

ING

S A

RE C

ON

FIDE

NTIA

L, A

ND

THE

EXC

LUSI

VE P

ROPE

RTY

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

AN

D A

RE N

OT T

O B

E DI

SCLO

SED

WITH

OUT

THE

EXPR

ESS

PERM

ISSI

ON

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

THE

Y M

AY

NO

T BE

USED

OR

DUP

LIC

ATE

D W

ITHO

UT TH

E EX

PRES

S PE

RMIS

SIO

N O

F w

ood

ley

arch

itect

ural

grou

p,in

c. C

OPY

RIG

HT©

2017

w

ood

ley

arch

itect

ural

grou

p,in

c. A

LL R

IGHT

S RE

SERV

ED.

woo

dle

yarc

hite

ctur

algr

oup,

inc.

c o l o r a d o

2943 S. Pullman Street, Suite ASanta Ana, California 92705

V. 949.553.8919 F. 949.553.8909

ca l i fo rn ia

731 SouthPark Dr., Suite BLittleton, Colorado 80120

V. 303.683.7231 F. 303.683.2922

PROJECT NO.:DRAWN BY:

PLAN NUMBER

SHEET NUMBER

FIRST ISSUE:DATE:

CORRECTIONS 08/13/20181 PLAN CHECK

TWEL

VE

BRID

GES

TRA

MO

NTE

LIN

CO

LN,

CA

LIFO

RNIA

WO

OD

SID

E HO

MES

WDSCA-1702

MS

01/29/2019

07/06/2018

CORRECTIONS2 PLANNING08/13/2018

FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD

A4-C2-2

FOUR

1. GLAZING SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH CRC SECTION R308.32. GLAZED PANELS REQUIRING SAFETY GLAZING SHALL BE IDENTIFIED WITH THE

WORD 'TEMPERED' OR 'TEMP' OR

GLAZING & FALL PROTECTION

SAFETY GLAZING

1. ALL GLAZING SHALL COMPLY WITH CRC SECTION R3082. ALL GLAZING SHALL BE DUAL PANE INSULATING GLASS U.N.O. IN THE TITLE 24

REPORT3. WINDOW CALLOUTS ARE AS FOLLOWS:

SL = SLIDER SH = SINGLE HUNGFG = FIXED GLASS CA = CASEMENT

1. WINDOW FALL PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITHSECTION R312.2.1 AND R312.2.2

2. IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW ISLOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR SURFACEBELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE AMINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICHTHE WINDOW IS LOCATED

WINDOW FALL PROTECTION

T

1. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE NOTLESS THAN ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING

EMERGENCY EGRESSEMERGENCY ESCAPE AND RESCUE OPENINGS

1. NOTE: EXTERIOR WINDOWS LABELED W/ AN SYMBOL SHALL BE DESIGNATEDFOR EMERGENCY EGRESS & RESCUE.

2. ESCAPE & RESCUE WINDOWS SHALL HAVE A MIN. NET CLEAR OPENABLE AREA OF5.7 SQ. FT. THE MIN. NET CLEAR OPENING SHALL BE NOT LESS THAN 24 INCHESHIGH AND 20 INCHES WIDE. WHEN WINDOWS ARE PROVIDED AS A MEANS OFESCAPE OR RESCUE, THEY SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOTGREATER THAN 44 INCHES MEASURED FROM THE FLOOR. THESE WINDOWS

3. ANY BARS, GRILLS GRATES OR OTHER SIMILAR DEVICES SHALL BE OPERATIONALFROM THE INSIDE OF ROOM WITHOUT THE USE OF KEYS OR TOOLS.

EEMERGENCY ESCAPE AND RESCUE WINDOWS

1. NOTE: EXTERIOR DOORS LABELED W/ AN SYMBOL SHALL BE DESIGNATED FOREMERGENCY EGRESS & RESCUE.

2. ESCAPE & RESCUE DOORS SHALL ARE PERMITTED TO BE SIDE HINGED OR A SLIDER.3. THE MINIMUM NET CLEAR HEIGHT OPENING FOR ANY DOOR THAT SERVES AS AN

EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE IN ACCORDANCE WITHSECTION R310.2.1

EEMERGENCY ESCAPE AND RESCUE DOORS

BATH AND SHOWER SPACES1. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED

SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITHNONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHTOF NOT LESS THAN 6 FEET ABOVE THE FLOOR. (SEC R307.2)

2. ALL GLASS SHOWER AND TUB/SHOWER DOORS SHALL BE TEMPERED.3. SHOWER AND TUB/SHOWER COMBINATIONS SHALL BE PROVIDED WITH

INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, ORCOMBINATION PRESSURE BALANCE/THERMOSTATIC MIXING VALVE TYPE THATPROVIDE SCALD AND THERMAL SHOCK PROTECTION. VALVES SHALL BEADJUSTED PER THE MANUFACTURER'S INSTRUCTIONS TO DELIVER A MAXIMUMMIXED WATER SETTING OF 120 DEGREES FAHRENHEIT.

4. PROVIDE 15" MINIMUM BETWEEN THE CENTER OF THE WATER CLOSET TO ANYSIDE WALL

5. PROVIDE 24" CLEAR SPACE IN FRONT OF ANY WATER CLOSET6. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS

SHALL BE PROVIDED NATURAL VENTILATION OR WITH MECHANICAL VENTILATIONCAPABLE OF 50 CFM EXHAUSTED DIRECTLY TO THE OUTSIDE (C.R.C. R303.3)

LAUNDRY ROOM NOTES1. UNLESS OTHERWISE PERMITTED OR REQUIRED BY THE DRYER MANUFACTURER'S

INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION,DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTALCOMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET, INCLUDING TWO 90DEGREE ELBOWS. A LENGTH OF 2 FEET SHALL BE DEDUCTED FOR EACH 90 DEGREEELBOW IN EXCESS OF TWO

2. PROVIDE 100 SQUARE INCHES OF MAKE-UP AIR TO ALL LAUNDRY ROOMS3. WASHER SPACE, PROVIDE RECESSED WATER AND WASTE4. AT 2ND FLOOR, PROVIDE "SMITTY" PAN UNDER WASHER WITH DRAIN TO OUTSIDE

SOFFIT SYMBOLSFLAT SOFFIT W/ TOP @ 9'-0" A.F.F. @ 10'-0" PL., @ 8'-0" A.F.F. @9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESS OTHERWISE NOTED

FLATTENED ARCH SOFFIT W/ TOP @ 9'-0" A.F.F. & SPRING POINT@ 8'-0" A.F.F. @ 10'-0" PL., TOP @ 8'-0" A.F.F & SPRING POINT @7'-0" A.F.F. @ 9'-0" PLATE OR TOP @ 7'-6" A.F.F & SPRING POINT@ 6'-6" A.F.F. @ 8'-0" PLATE UNLESS OTHERWISE NOTED

WALL LEGEND2X4 WALL

2X6 WALL

2X LOW WALL - HEIGHTPER FLOOR PLAN

FULL ARCH SOFFIT W/ TOP OF ARCH @ 9'-0" A.F.F. @ 10'-0" PL.,8'-0" A.F.F. @ 9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESSOTHERWISE NOTED

ELLIPTICAL ARCH SOFFIT AS NOTED IN PLAN OR ELEVATION

Page 8: group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with nonabsorbent surface. such wall surfaces shall extend to a height of not less than 6

LEFT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

1'-0"312

COVERED PORCHPARTIAL LEFT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

WINDOW AT OPT.HOME-PLUS

412

412

412

412

412

412 4

12

402-02AD TYP.

1303-01AD

103-01AD

603-01AD

404-01AD

1X4WDTRIM

904-01AD

1204-01AD

804-01AD

1X4WDTRIM

RIGHT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

1'-0"

EQ. EQ.

412 4

12

412

1101-01AD

1201-01AD

1302-02AD

402-02AD TYP.

105-01AD

1105-01AD

605-01AD

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

PARTIALLEFT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE

OPT. CENTER MEET SLIDER 402-02AD TYP.

PARTIALRIGHT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

312

412

THES

E DE

SIG

NS

AN

D DR

AW

ING

S A

RE C

ON

FIDE

NTIA

L, A

ND

THE

EXC

LUSI

VE P

ROPE

RTY

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

AN

D A

RE N

OT T

O B

E DI

SCLO

SED

WITH

OUT

THE

EXPR

ESS

PERM

ISSI

ON

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

THE

Y M

AY

NO

T BE

USED

OR

DUP

LIC

ATE

D W

ITHO

UT TH

E EX

PRES

S PE

RMIS

SIO

N O

F w

ood

ley

arch

itect

ural

grou

p,in

c. C

OPY

RIG

HT©

2017

w

ood

ley

arch

itect

ural

grou

p,in

c. A

LL R

IGHT

S RE

SERV

ED.

woo

dle

yarc

hite

ctur

algr

oup,

inc.

c o l o r a d o

2943 S. Pullman Street, Suite ASanta Ana, California 92705

V. 949.553.8919 F. 949.553.8909

ca l i fo rn ia

731 SouthPark Dr., Suite BLittleton, Colorado 80120

V. 303.683.7231 F. 303.683.2922

PROJECT NO.:DRAWN BY:

PLAN NUMBER

SHEET NUMBER

FIRST ISSUE:DATE:

CORRECTIONS 08/13/20181 PLAN CHECK

TWEL

VE

BRID

GES

TRA

MO

NTE

LIN

CO

LN,

CA

LIFO

RNIA

WO

OD

SID

E HO

MES

WDSCA-1702

MS

01/29/2019

07/06/2018

CORRECTIONS2 PLANNING08/13/2018

FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD

A4-C5-1

FOUR

2

3

Page 9: group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with nonabsorbent surface. such wall surfaces shall extend to a height of not less than 6

LEFT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

1'-0"312

COVERED PORCHPARTIAL LEFT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

WINDOW AT OPT.HOME-PLUS

412

412

412

412

412

412 4

12

- ENHANCED

502-02AD

205-01AD

705-01AD

1205-01AD

305-01AD

805-01AD

1305-01AD

24"X

48"

24"X

48"

303-01AD

803-01AD

4" LAP SIDING BYLP SMARTSIDE

RIGHT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

1'-0"

EQ. EQ.

412 4

12

412

- ENHANCED

205-01AD

705-01AD

1205-01AD

COMPOSITESHUTTERS

307-01AD

18"X

60"

18"X

60"

18"X

60"

18"X

60"

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

PARTIALLEFT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE

OPT. CENTER MEET SLIDER

- ENHANCED

403-01AD

903-01AD

205-01AD

705-01AD

1205-01AD

PARTIALRIGHT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE

8'-0

"

FIN. FLR.T.O. GRADE

9'-1

"

T.O. WIN.

T.O. PLATE

8'-0

"

FIN. FLR.

9'-1

"

T.O. WIN.

T.O. PLATE

312

412

- ENHANCED

THES

E DE

SIG

NS

AN

D DR

AW

ING

S A

RE C

ON

FIDE

NTIA

L, A

ND

THE

EXC

LUSI

VE P

ROPE

RTY

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

AN

D A

RE N

OT T

O B

E DI

SCLO

SED

WITH

OUT

THE

EXPR

ESS

PERM

ISSI

ON

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

THE

Y M

AY

NO

T BE

USED

OR

DUP

LIC

ATE

D W

ITHO

UT TH

E EX

PRES

S PE

RMIS

SIO

N O

F w

ood

ley

arch

itect

ural

grou

p,in

c. C

OPY

RIG

HT©

2017

w

ood

ley

arch

itect

ural

grou

p,in

c. A

LL R

IGHT

S RE

SERV

ED.

woo

dle

yarc

hite

ctur

algr

oup,

inc.

c o l o r a d o

2943 S. Pullman Street, Suite ASanta Ana, California 92705

V. 949.553.8919 F. 949.553.8909

ca l i fo rn ia

731 SouthPark Dr., Suite BLittleton, Colorado 80120

V. 303.683.7231 F. 303.683.2922

PROJECT NO.:DRAWN BY:

PLAN NUMBER

SHEET NUMBER

FIRST ISSUE:DATE:

CORRECTIONS 08/13/20181 PLAN CHECK

TWEL

VE

BRID

GES

TRA

MO

NTE

LIN

CO

LN,

CA

LIFO

RNIA

WO

OD

SID

E HO

MES

WDSCA-1702

MS

01/29/2019

07/06/2018

CORRECTIONS2 PLANNING08/13/2018

FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD

A4-C5-1E

FOUR

Page 10: group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with nonabsorbent surface. such wall surfaces shall extend to a height of not less than 6

SECOND FLOOR PLAN 'A'1/4" = 1/-0" MODERN SPANISH

90°

90°

90°

90°

90°

90°

90°

90°

90°

90°

90°

90°

OPT. CABS

90°

90°

OPT

2668

DR

OPTIONALSINK/CABS

OPT

2468

DR

OPT.UPPERS

15°

UTILITY -

HE

CEILING LIGHTCENTERED INROOM.PRE-WIRE FORFAND

+44"GFCI

3V

3

V H

WPHE

HE

CEILING LIGHTCENTERED INROOM.PRE-WIRE FORFAN

D

+44"GFCI

WPHE

HE

CEILING LIGHTCENTERED INROOM.PRE-WIRE FORFAN

CAT5RG6

S

S

S

S

S CM

CAT5RG6

PRE-WIREFOR FAN

HECENTERED

D

HE

HE

3'-0

"6'

-0"

V

4'-0"

+44"GFCI

+32"GFCI

+32"GFCI

+44"GFCI

WPHEWP

HE

HECENTERED

V

H

V H V

HE

3V AT OPT. DOOR

+36"220VGFCI

FG

+54"GFCI

C.W.

H.W.

+44"GFCI

C

HE

HE

V

HE HE HE

HE

HE

HE

HE HE

3

3

3

33

TO STAIRLIGHT SWITCHBELOW

D

HE

HE

TO SWITCHBELOW

CENTER ONSLIDER BELOW

4'-0

"8'

-9"

1'-9"

4'-5

"6'

-6"

4'-2"9'-0"

9'-0

"

1'-9"

4'-6" 4'-6"2'-512"

MASTERBEDROOM

MASTERBATH

HERW.I.C.

HISW.I.C.

LAU.

LOFT

BEDROOM 3

BEDROOM 2

BEDROOM 4

BATH 2

BATH 3

HALL

S

V

PROVIDE CAT5e CABLE FROMSTRUCTURED WIRE PANEL TO ALLTHERMOSTATS & ELECTRICALSERVICE PANELHOME RUN BOX FORSTRUCTURED WIRING(LOW VOLTAGE) - 1"CONDUIT

CAT5VOICE/DATA

HE HE

HE HE

3'-6"

3'-6

"3'-6"

6'-0

"

THES

E DE

SIG

NS

AN

D DR

AW

ING

S A

RE C

ON

FIDE

NTIA

L, A

ND

THE

EXC

LUSI

VE P

ROPE

RTY

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

AN

D A

RE N

OT T

O B

E DI

SCLO

SED

WITH

OUT

THE

EXPR

ESS

PERM

ISSI

ON

OF

woo

dle

yar

chite

ctur

algr

oup,

inc.

THE

Y M

AY

NO

T BE

USED

OR

DUP

LIC

ATE

D W

ITHO

UT TH

E EX

PRES

S PE

RMIS

SIO

N O

F w

ood

ley

arch

itect

ural

grou

p,in

c. C

OPY

RIG

HT©

2017

w

ood

ley

arch

itect

ural

grou

p,in

c. A

LL R

IGHT

S RE

SERV

ED.

woo

dle

yarc

hite

ctur

algr

oup,

inc.

c o l o r a d o

2943 S. Pullman Street, Suite ASanta Ana, California 92705

V. 949.553.8919 F. 949.553.8909

ca l i fo rn ia

731 SouthPark Dr., Suite BLittleton, Colorado 80120

V. 303.683.7231 F. 303.683.2922

PROJECT NO.:DRAWN BY:

PLAN NUMBER

SHEET NUMBER

FIRST ISSUE:DATE:

CORRECTIONS 08/13/20181 PLAN CHECK

TWEL

VE

BRID

GES

TRA

MO

NTE

LIN

CO

LN,

CA

LIFO

RNIA

WO

OD

SID

E HO

MES

WDSCA-1702

MS

01/29/2019

07/06/2018

CORRECTIONS2 PLANNING08/13/2018

FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD

1. PER SECTION R309.8, NEWLY CONSTRUCTED ONE AND TWOFAMILY DWELLINGS AND TOWNHOUSES WITH ATTACHED PRIVATEGARAGES SHALL COMPLY WITH EV INFRASTRUCTUREREQUIREMENTS IN ACCORDANCE WITH CALIFORNIA GREENBUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.1.

2. FOR EACH DWELLING UNIT, INSTALL A LISTED RACEWAY TOACCOMMODATE A DEDICATED 208/240 VOLT BRANCH CIRCUIT.RACEWAYS ARE REQUIRED TO BE CONTINUOUS AT ENCLOSED,INACCESSIBLE, OR CONCEALED AREAS AND SPACES

3. THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALLIDENTIFY THE OVERCURRENT PROTECTIVE DEVICE SPACE(S)RESERVED FOR FUTURE EV CHARGING AS "EV CAPABLE". THERACEWAY TERMINATION LOCATION SHALL BE PERMANENTLYAND VISIBLY MARKED AS "EV CAPABLE"

ELECTRIC VEHICLE NOTES

GENERAL UTILITY NOTES1. ELECTRICAL, MECHANICAL AND PLUMBING SYSTEMS ARE SHOWN FOR

INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THECONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION &PLACEMENT. ALL HEIGHTS SHOWN ARE TO CENTERLINE OF FIXTURE.

2. PANEL BOARDS ARE NOT ALLOWED IN STORAGE CLOSETS ORBATHROOMS

3. ELECTRICAL EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING LAB4. ELECTRICAL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS OF

MORE THAN 50 VOLTS SHALL HAVE A POSITIVE MEANS OF DISCONNECTADJACENT TO AND IN SIGHT FROM THE EQUIPMENT SERVED.

5. ALL FIXTURES INSTALLED IN DAMP OR WET LOCATIONS SHALL BE MARKED'SUITABLE FOR WET LOCATIONS'

6. CLOTHES DRYERS TO HAVE 4-WIRE GROUNDED ELECTRICAL OUTLET7. BOND GROUNDING ELECTRODE TO METAL GAS AND WATER PIPING,

POINTS OF ATTACHMENT OF THE BONDING JUMPER(S) TO BEACCESSIBLE

8. ARC FAULT INTERRUPTER CIRCUITS: ALL 120-VOLT, SINGLE PHASE, 15 AND20 AMPRE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED INDWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVINGROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, ORSIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTEDARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE, INSTALLED TOPROVIDE PROTECTION OF THE BRANCH CIRCUIT.

LOW VOLTAGE NOTES1. CARBON MONOXIDE DETECTORS TO BE 110 VOLT W/ BATTERY BACKUP

AND SHALL BE INTERCONNECTED SO THAT IF AN ALARM SOUNDED INONE ROOM, IT SHALL BE SOUNDED IN ALL THE OTHERS, & SHALL BELOCATED ON EVERY LEVEL OF THE DWELLING AND IN THE IMMEDIATEVICINITY OF THE BEDROOMS, PER CRC R314 & R315.

2. SMOKE DETECTORS TO BE 110 VOLT W/ BATTERY BACKUP AND SHALL BEINTERCONNECTED SO THAT IF AN ALARM SOUNDED IN ONE ROOM, ITSHALL BE SOUNDED IN ALL THE OTHERS, & SHALL BE LOCATED ON EVERYLEVEL OF THE DWELLING, IN THE IMMEDIATE VICINITY OF THE BEDROOMSAND IN EACH SLEEPING ROOM, PER CRC R314 & R315.

3. SMOKE ALARMS OR SMOKE DETECTORS SHALL BE INSTALLED A MINIMUMOF 20 FEET HORIZONTAL DISTANCE FROM A PERMANENTLY INSTALLEDCOOKING APPLIANCE WITH THE EXCEPTION OF IONIZATION SMOKEALARMS WITH AN ALARM-SILENCING SWITCH OR PHOTOELECTRIC SMOKEALARMS, WHICH SHALL BE PERMITTED TO BE INSTALLED 10 FEET ORGREATER FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. (NFPA72 SECTION 29.8.3.4)

MECHANICAL NOTES1. FUEL BURNING EQUIPMENT SHALL BE EQUIPPED WITH AN APPROVED

AUTOMATIC MEANS WHICH WILL SHUT OFF FUEL SUPPLY TO EQUIPMENTIN THE EVENT OF IGNITION OR FLAME FAILURE.

2. BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BEDUCTED TO TERMINATE OUTSIDE THE BUILDING. UNLESS FUNCTIONINGAS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANSMUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILYACCESSIBLE

3. EXHAUST FANS WITH A COMMON EXHAUST SHALL BE PROVIDED WITH ABACKDRAFT DAMPER TO PREVENT RECIRCULATION

4. MECHANICAL WHOLE HOUSE VENTILATION TO BE PROVIDED, INCOMPLIANCE WITH ASHRAE 62.2 PER 2016 ENERGY CODE

5. EXHAUST FAN FOR LOCAL AND WHOLE HOUSE VENTILATION (CFM'S PERTABLE 4-7 OF THE 2016 RESIDENTIAL COMPLIANCE MANUAL).

6. EXHAUST FANS FOR LOCAL VENTILATION MUST BE RATED AT A MINIMUMOF 50 CFM AND PROPERLY DUCTED TO THE OUTSIDE PER ASHRAE 622,TABLE 7-1. FANS IN WET LOCATIONS TO HAVE HUMIDISTAT SWITCH.

7. RANGE HOOD VENTILATION FOR THE KITCHEN MUST BE RATED AT AMINIMUM OF 100 CFM AT WORKING SPEED AND PROPERLY DUCTED TOTHE OUTSIDE PER ASHRAE 622, TABLE 7-1.

8. SWITCH FOR CONTINUOUS FAN TO BE LABELED OR OTHER APPROVEDMEANS BY BUILDING DEPARTMENT.

9. FOR CONTINUOUS VENTILATION, EXHAUST FAN MUST BE RATED 1.0 SONEOR LESS. IF INTERMITTENT VENTILATION IS USED, THE EXHAUST FAN MUSTBE RATED 3.O SONES OR LESS.

ELECTRICAL NOTES1. PROVIDE GFCI PROTECTED OUTLETS AT THE FOLLOWING LOCATIONS:

BATHROOMS, GARAGES EXCEPT THOSE THAT ARE NOT READILYACCESSIBLE, OUTDOORS, CRAWL SPACES LOCATED AT OR BELOWGRADE LEVEL, UNFINISHED BASEMENTS, ALL KITCHEN COUNTERTOPS,AND WITHIN 6'-0" OF LAUNDRY OR WET BAR SINKS

2. RECEPTACLE OUTLETS AT KITCHEN COUNTERTOPS SHALL BE SPACED SOTHAT NO PORTION OF THE COUNTERTOP IS FURTHER THAN 24" FROM ANOUTLET

3. WALL OUTLETS IN HABITABLE ROOMS SHALL BE SPACED SO THAT NOPOINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6'-0"FROM AN OUTLET AND THAT NO WALL 2' OR GREATER DOES NOT HAVEAN OUTLET

4. WEATHER PROTECT OUTDOOR RECEPTACLE. RECEPTACLES LOCATED INA WET LOCATION SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOFWHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. AN OUTLETBOX HOOD INSTALLED FOR THIS PURPOSE SHALL BE LISTED AND SHALL BEIDENTIFIED AS "EXTRA DUTY"

5. PROVIDE ONE ELECTRICAL OUTLET IN HALLWAYS AT LEAST 10'-0" LONG6. OUTLET BOXES FOR CEILING FANS SHALL BE LISTED SPECIFICALLY FOR

THAT USE AND BE DESIGNED TO SUPPORT 70 LB PADDLE FANS7. PROVIDE SWITCH CONTROLLED LIGHTING OUTLETS AT ALL ROOMS,

GARAGES AND OUTDOOR ENTRANCES8. NOT USED9. RECESSED LIGHTING IN INSULATED CLG'S SHALL BE RATED BY U.L.10. BATHROOM OUTLETS SHALL BE SERVED BY A SEPARATE 20 AMP CIRCUIT

HOWEVER, THIS CIRCUIT IS PERMITTED TO SUPPLY THE REQUIREDRECEPTACLES IN MORE THAN ONE BATHROOM

11. ALL RECEPTACLES THAT SERVE THE COUNTER AREA SHALL BE GFIPROTECTED IN KITCHEN AREA

12. PROVIDE MIN. TWO (2) 20-AMP SMALL APPLIANCE BRANCH CIRCUITSFOR KITCHEN AND SHALL HAVE NO OTHER OUTLETS

13. BATHROOM CIRCUITS SHALL HAVE NO OTHER OUTLETS, MINIMUM20-AMP CIRCUIT

14. PROVIDED AT GROUND FAULT CIRCUIT INTERRUPTER AT KITCHENS, BATHROOMS, GARAGES AND LAUNDRY ROOMS

15. ALL 125-VOLT, 15- AND 20- AMPERE RECEPTACLES TO BE LISTEDTAMPER-RESISTANT RECEPTACLES IN ALL AREAS SPECIFIED PER CECSECTION 210.52. (CEC 406.11)

16. PROVIDE 110V SERVICE OUTLET SWITCH, FLUORESCENT LIGHT W/VACANCY SENSOR FOR ATTIC ACCESS AT FAU LOCATION.

17. ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCEWITH TABLE 150.0-A (CALIFORNIA ENERGY CODE - 150.0 K 1. A)

PLUMBING NOTES1. OVER AND UNDER GAS AND ELECTRICAL METERS ARE NOT ALLOWED.2. WHEN SINGLE SHOWER FIXTURES ARE SERVED BY MORE THAN ONE

SHOWERHEAD, THE COMBINED FLOW RATE OF ALL SHOWERHEADSSHALL NOT EXCEED THE MAXIMUM FLOW RATES SPECIFIED IN THE 2016CALIFORNIA GREEN CODE

1. THE MAIN SERVICE PANEL SHALL HAVE A MINIMUM BUSBARRATING OF 200 AMPS.

2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVEDSPACE TO ALLOW FOR INSTALLATION OF A DOUBLE POLE CIRCUITBREAKER FOR FUTURE SOLAR ELECTRIC INSTALLATION. THERESERVED SPACE SHALL BE POSITIONED AT THE OPPOSITE (LOAD)END OF THE INPUT FEEDER LOCATION OR MAIN CIRCUITLOCATION AND SHALL BE PERMANENTLY MARKED AS "FORFUTURE SOLAR ELECTRIC".

3. PROVIDE PATHWAY FOR ROUTING PLUMBING FROM SOLAR ZONETO WATER HEATING SYSTEM

4. PROVIDE PATHWAY FOR ROUTING CONDUIT FROM SOLAR ZONETO MAIN SERVICE PANEL.

FUTURE SOLAR NOTES

UTILITY SYMBOLS

+XX"

C

120V DUPLEX CONVENIENCE TAMPER RESISTANT RECEPTACLE W/ARC FAULT CIRCUIT INTERRUPT, INSTALLED 12" ABOVE FF (U.O.N.)

120V 4-PLEX CONVENIENCE TAMPER RESISTANT RECEPTACLE

120V FLOOR TYPE TAMPER RESISTANT RECEPTACLE W/ COVER

120V DUPLEX CONVENIENCE TAMPER RESISTANT RECEPTACLE, 1/2HOT, THE OTHER HALF SWITCH CONTROLLED

220V SINGLE CONVENIENCE TAMPER RESISTANT RECEPTACLEINSTALLED 12" ABOVE FINISHED FLOOR (U.O.N.)

TWO-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVECOUNTER (U.O.N.)

MANUAL ON, TWO-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR8" ABOVE COUNTER (U.O.N.) W/ VACANCY SENSOR

TWO-POLE DIMMER LIGHT SWITCH AT 42" ABOVE FLOOR OR 8"ABOVE COUNTER (U.O.N.)

THREE-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVECOUNTER (U.O.N.)

FOUR-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVECOUNTER (U.O.N.)

HUMIDISTAT

PHONE JACK (CAT5) INSTALLED 12" ABOVE FINISHED FLOOR OR 8"ABOVE COUNTER (U.N.O.)

TELEVISION (RG6) / PHONE JACK (CAT5) INSTALLED 12" ABOVEFINISHED FLOOR OR 8" ABOVE COUNTER (U.N.O.)

WALL MOUNTED LIGHT FIXTURE, SEE PLANS FOR HEIGHT

SURFACE MOUNTED CEILING LIGHT FIXTURE

RECESSED LIGHT FIXTURE

HANGING LIGHT FIXTURE

RECESSED COMBINATION EXHAUST FAN/LIGHT, SWITCHCONTROLLED

CONTINUOUS FAN COMPLIANT WITH ASHRAE 62.2. VENT TOEXTERIOR WITH 6" DUCT

LOCAL EXHAUST FAN COMPLIANT WITH ASHRAE 62.2. MIN. 50 CFMMAX 3 SONE OR EXCEEDS 400 CFM

RECESSED "EYE-BALL" CAN LIGHT FIXTURE

FUEL GAS OUTLET FUEL

GAS LOOSE KEY VALVE

PUSH BUTTON FOR GARAGE DOOR OPENER OR CHIMES

JUNCTION BOX, W/ COVER OR ADAPTER AS REQUIRED (VOLTAGEAS INDICATED)

THERMOSTAT VERIFY LOCATION W/ HVAC LAYOUT

HOSE BIBB

HOSE BIBB WITH SHUT OFF VALVE

ILLUMINATED ADDRESS NUMBERS

SMOKE DETECTOR, REFER TO LOW VOLTAGE NOTES

SMOKE/CARBON MONOXIDE DETECTOR COMBO, REFER TO LOWVOLTAGE NOTES

CARBON MONOXIDE DETECTOR, REFER TO LOW VOLTAGE NOTES

DOOR CHIMES, SEE PLANS FOR HEIGHT

UNDER CABINET, SURFACE MOUNTED 24" LIGHT AS REQUIRED BYCALIFORNIA TITLE 24, 40 LUMENS/WATT

SURFACE MOUNTED CEILING FAN, SWITCH CONTROLLED W/OPTIONAL INCANDESCENT LIGHT

12"X48" SINGLE TUBE OR 24'X48" DOUBLE TUBE CEILING MOUNTEDFIXTURE, SWITCH CONTROLLED, 40 LUMENS/WATT

V

D

3

4

H

RG6

SYMBOL LEGEND:

WP = WATER PROOFVP = VAPOR PROOFGFCI = GROUND FAULT CIRCUIT INTERRUPTERF = FLUORESCENTLED = LIGHT EMITTING DIODEHE = HIGH EFFICACY

B

J

T

SOV

S

SCM

CM

FOUR

AE4-2

3

3