group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with...
Transcript of group,inc. woodley group,inc....shower heads and in shower compartments shall be finished with...
PLAN FOURFIRST FLOOR = 2034 SQ. FT.
SECOND FLOOR = 1970 SQ. FT.
TOTAL = 4004 SQ. FT.
3-BAY GARAGE = 869 SQ. FT.
COVERED PORCH = 33 SQ. FT.
LOT COVERAGE = 2945 SQ. FT.
MAX. LOT COVERAGE = 3938 SQ. FT.
OPT. OUTDOOR LIVING = +181 SQ. FT.
- A
SECOND FLOOR PLAN 'A'1/4" = 1/-0" MODERN SPANISH
DN
90°
D
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
OPT. CABS
90°
OPEN TOBELOW
MASTERBEDROOM
9'-0" CLG.CARPET
MASTERBATH9'-0" CLG.
HS
HERW.I.C.9'-0" CLG.CARPET
HISW.I.C.9'-0" CLG.CARPET
90°
OPT
2668
DR
SEA
T - 1
8"A
FF
2480
S & P
S &
P
S &
P
S &
P
S & P
S & P
OPTIONALSINK/CABS
STD
.UP
PERS
LAU.9'-0" CLG.
HS
2480
2880
LOFT9'-0" CLG.CARPET
BEDROOM 39'-0" CLG.CARPET
BEDROOM 29'-0" CLG.CARPET
BEDROOM 49'-0" CLG.CARPET
BATH 29'-0" CLG.
HS
S & P
S & P
BATH 39'-0" CLG.
HS
MC
MC
MC
S &
P
OPT
2468
DR
2680
2480
2480
2680
24802680
4080 BP
4080 BP
5080
BP
2480
2680
2480
T
T
T
T
E
E
E
E
HALL9'-0" CLG.CARPET
BA4-A4-0
AA4-A4-0
BA4-A4-0
AA4-A4-0
60'-0"
50'-8
1 2"
60'-0"
50'-2
1 2"
7'-4
1 2"31
'-111 2"
10'-1
01 2"
12'-1" 12'-1012" 13'-71
2" 6'-0"10'-11
2"5'-31
2"
3'-1" 2'-0" 3'-6" 2'-0" 3'-012" 3'-1" 2'-0" 2'-0" 3'-01
2"
1'-0
"
1'-0
"42
'-4"
7'-4
1 2"
8'-312" 15'-2" 36'-61
2"
1'-1012" 2'-31
2"4'-61
2" 1'-11"
2040SH
3050SH
3050SH
4018FX
3050SH
2650
SH5050
FX2650
SH
3050
FX 3050
FX 3050
FX 2050
SH
3050SH
3050SH
3050SH
4040SL
3050 SH
3050 SH
3050 SH 20
40 SH
2040 SH
2040
SH
2040 SH
3050 SH
LINE OFSTONEVENEER
6"6"
6"
30"X30"ATTICACCESS
410-01AD
109-01AD
1109-01AD
FAU & PASSAGEWAY IN ATTIC.5'X10' PLATFORM
3'-6
"
6'-4
"8'
-21 2"
11'-4
1 2"5'
-31 2"
11'-1
1 2"4'
-7"
2'-9
1 2"
5'-5
1 2"5'
-8"
2'-9
1 2"2'
-6"
9'-1
1 2"2'
-3"
1'-1
0"4'
-6"
12'-9"2'-8"16'-2"4'-1112"3'-4"4'-3"4'-3"3'-4"
2'-312"2'-21
2"5'-1012"8'-1"
2'-9
1 2"4'
-7"
12'-1
11 2"18
'-0"
1'-0
"
9'-2
"8'
-10"
6'-012" 6'-01
2"
8'-812"4'-2"
1'-0
"3'
-11"
3'-6
"3'
-111 2"
712"8'-41
2"6'-2
"5'
-0"
6'-1
0"
7"
5'-112" 3'-3" 3'-6"
3'-6" 6" 8'-10" 3'-912"
1'-8"
1'-8
"
4'-0
"
4'-1
0"4'
-01 2"
5'-1
"1'
-31 2"
11'-4
1 2"1'
-0"
17'-6
"31 2"
3'-6" 11'-612"
4'-412" 4'-4" 11'-71
2"
5'-6" 5'-2" 5'-312"
3'-6"312"
11'-5
"10
'-8"
31 2"5'
-5"
2'-8
"11
'-101 2"
3'-0" 3'-0"
1'-4
"
2'-1"
1'-4
"6'
-31 2"
3'-0" 1'-0"
19'-9
"
32"x60" TUB/SHWR. COMBOW/ ROD PERSPECS.
TOW
EL B
AR
TOW
EL B
AR
1'-7
"
1'-612"
32"x60" TUB/ SHWR.COMBO W/ ROD PERSPECS.
312"14'-10"
LOW WALL(42" MIN.)
709-01AD
2'-2"
WASHER ALWAYSON LEFT.PROVIDERECESSEDWATER, WASTE &SMITTY PAN
510-01AD
5'-2"
36" CLR. MIN.WASHERALWAYSON LEFT
3'-4
"
T T
1410-01AD
36"x66"FREESTANDINGOVAL TUB,PER SPECS
SHOWERPER SPECS
MECH. CHASE,TYP
TOW
EL B
AR
TOWEL BAR
610-01AD
2
1 3
4
5
6
STRUCTUREDWIRINGBOX
7'-6"SOFFIT
OPT.UPPERS
36"X
60" S
HOW
ER P
AN
15°
2480
LIN
EN
6'-212"2"
3'-1
11 2"
9'-4"2'-312"
MC
THES
E DE
SIG
NS
AN
D DR
AW
ING
S A
RE C
ON
FIDE
NTIA
L, A
ND
THE
EXC
LUSI
VE P
ROPE
RTY
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
AN
D A
RE N
OT T
O B
E DI
SCLO
SED
WITH
OUT
THE
EXPR
ESS
PERM
ISSI
ON
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
THE
Y M
AY
NO
T BE
USED
OR
DUP
LIC
ATE
D W
ITHO
UT TH
E EX
PRES
S PE
RMIS
SIO
N O
F w
ood
ley
arch
itect
ural
grou
p,in
c. C
OPY
RIG
HT©
2017
w
ood
ley
arch
itect
ural
grou
p,in
c. A
LL R
IGHT
S RE
SERV
ED.
woo
dle
yarc
hite
ctur
algr
oup,
inc.
c o l o r a d o
2943 S. Pullman Street, Suite ASanta Ana, California 92705
V. 949.553.8919 F. 949.553.8909
ca l i fo rn ia
731 SouthPark Dr., Suite BLittleton, Colorado 80120
V. 303.683.7231 F. 303.683.2922
PROJECT NO.:DRAWN BY:
PLAN NUMBER
SHEET NUMBER
FIRST ISSUE:DATE:
CORRECTIONS 08/13/20181 PLAN CHECK
TWEL
VE
BRID
GES
TRA
MO
NTE
LIN
CO
LN,
CA
LIFO
RNIA
WO
OD
SID
E HO
MES
WDSCA-1702
MS
01/29/2019
07/06/2018
CORRECTIONS2 PLANNING08/13/2018
FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD
A4-A2-2
FOUR
1. GLAZING SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH CRC SECTION R308.32. GLAZED PANELS REQUIRING SAFETY GLAZING SHALL BE IDENTIFIED WITH THE
WORD 'TEMPERED' OR 'TEMP' OR
GLAZING & FALL PROTECTION
SAFETY GLAZING
1. ALL GLAZING SHALL COMPLY WITH CRC SECTION R3082. ALL GLAZING SHALL BE DUAL PANE INSULATING GLASS U.N.O. IN THE TITLE 24
REPORT3. WINDOW CALLOUTS ARE AS FOLLOWS:
SL = SLIDER SH = SINGLE HUNGFG = FIXED GLASS CA = CASEMENT
1. WINDOW FALL PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITHSECTION R312.2.1 AND R312.2.2
2. IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW ISLOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR SURFACEBELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE AMINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICHTHE WINDOW IS LOCATED
WINDOW FALL PROTECTION
T
1. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE NOTLESS THAN ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING
EMERGENCY EGRESSEMERGENCY ESCAPE AND RESCUE OPENINGS
1. NOTE: EXTERIOR WINDOWS LABELED W/ AN SYMBOL SHALL BE DESIGNATEDFOR EMERGENCY EGRESS & RESCUE.
2. ESCAPE & RESCUE WINDOWS SHALL HAVE A MIN. NET CLEAR OPENABLE AREA OF5.7 SQ. FT. THE MIN. NET CLEAR OPENING SHALL BE NOT LESS THAN 24 INCHESHIGH AND 20 INCHES WIDE. WHEN WINDOWS ARE PROVIDED AS A MEANS OFESCAPE OR RESCUE, THEY SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOTGREATER THAN 44 INCHES MEASURED FROM THE FLOOR. THESE WINDOWS
3. ANY BARS, GRILLS GRATES OR OTHER SIMILAR DEVICES SHALL BE OPERATIONALFROM THE INSIDE OF ROOM WITHOUT THE USE OF KEYS OR TOOLS.
EEMERGENCY ESCAPE AND RESCUE WINDOWS
1. NOTE: EXTERIOR DOORS LABELED W/ AN SYMBOL SHALL BE DESIGNATED FOREMERGENCY EGRESS & RESCUE.
2. ESCAPE & RESCUE DOORS SHALL ARE PERMITTED TO BE SIDE HINGED OR A SLIDER.3. THE MINIMUM NET CLEAR HEIGHT OPENING FOR ANY DOOR THAT SERVES AS AN
EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE IN ACCORDANCE WITHSECTION R310.2.1
EEMERGENCY ESCAPE AND RESCUE DOORS
BATH AND SHOWER SPACES1. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED
SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITHNONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHTOF NOT LESS THAN 6 FEET ABOVE THE FLOOR. (SEC R307.2)
2. ALL GLASS SHOWER AND TUB/SHOWER DOORS SHALL BE TEMPERED.3. SHOWER AND TUB/SHOWER COMBINATIONS SHALL BE PROVIDED WITH
INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, ORCOMBINATION PRESSURE BALANCE/THERMOSTATIC MIXING VALVE TYPE THATPROVIDE SCALD AND THERMAL SHOCK PROTECTION. VALVES SHALL BEADJUSTED PER THE MANUFACTURER'S INSTRUCTIONS TO DELIVER A MAXIMUMMIXED WATER SETTING OF 120 DEGREES FAHRENHEIT.
4. PROVIDE 15" MINIMUM BETWEEN THE CENTER OF THE WATER CLOSET TO ANYSIDE WALL
5. PROVIDE 24" CLEAR SPACE IN FRONT OF ANY WATER CLOSET6. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS
SHALL BE PROVIDED NATURAL VENTILATION OR WITH MECHANICAL VENTILATIONCAPABLE OF 50 CFM EXHAUSTED DIRECTLY TO THE OUTSIDE (C.R.C. R303.3)
LAUNDRY ROOM NOTES1. UNLESS OTHERWISE PERMITTED OR REQUIRED BY THE DRYER MANUFACTURER'S
INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION,DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTALCOMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET, INCLUDING TWO 90DEGREE ELBOWS. A LENGTH OF 2 FEET SHALL BE DEDUCTED FOR EACH 90 DEGREEELBOW IN EXCESS OF TWO
2. PROVIDE 100 SQUARE INCHES OF MAKE-UP AIR TO ALL LAUNDRY ROOMS3. WASHER SPACE, PROVIDE RECESSED WATER AND WASTE4. AT 2ND FLOOR, PROVIDE "SMITTY" PAN UNDER WASHER WITH DRAIN TO OUTSIDE
SOFFIT SYMBOLSFLAT SOFFIT W/ TOP @ 9'-0" A.F.F. @ 10'-0" PL., @ 8'-0" A.F.F. @9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESS OTHERWISE NOTED
FLATTENED ARCH SOFFIT W/ TOP @ 9'-0" A.F.F. & SPRING POINT@ 8'-0" A.F.F. @ 10'-0" PL., TOP @ 8'-0" A.F.F & SPRING POINT @7'-0" A.F.F. @ 9'-0" PLATE OR TOP @ 7'-6" A.F.F & SPRING POINT@ 6'-6" A.F.F. @ 8'-0" PLATE UNLESS OTHERWISE NOTED
WALL LEGEND2X4 WALL
2X6 WALL
2X LOW WALL - HEIGHTPER FLOOR PLAN
FULL ARCH SOFFIT W/ TOP OF ARCH @ 9'-0" A.F.F. @ 10'-0" PL.,8'-0" A.F.F. @ 9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESSOTHERWISE NOTED
ELLIPTICAL ARCH SOFFIT AS NOTED IN PLAN OR ELEVATION
3
3
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
LEFT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
3'-0
"
312
412
WINDOW AT OPT.HOME-PLUS
412
412
1201-01AD
902-01AD
ATWALL
1303-01AD
103-01AD
603-01AD
1204-01AD
504-01AD
1004-01AD
4" CASTSTONE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
RIGHT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
1'-0"
EQ. EQ.
3'-0
"
412 4
12
1101-01AD
701-01AD
2" CASTSTONE
1002-01AD
2x6 BARGERAFTER,
TYP.
502-01AD
TYP.
105-01AD
1105-01AD
605-01AD
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
PARTIALLEFT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH
OPT. CENTER MEET SLIDER502-01AD
TYP.
PARTIALRIGHT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
312
1002-01AD
2x6 BARGERAFTER,TYP.
THES
E DE
SIG
NS
AN
D DR
AW
ING
S A
RE C
ON
FIDE
NTIA
L, A
ND
THE
EXC
LUSI
VE P
ROPE
RTY
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
AN
D A
RE N
OT T
O B
E DI
SCLO
SED
WITH
OUT
THE
EXPR
ESS
PERM
ISSI
ON
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
THE
Y M
AY
NO
T BE
USED
OR
DUP
LIC
ATE
D W
ITHO
UT TH
E EX
PRES
S PE
RMIS
SIO
N O
F w
ood
ley
arch
itect
ural
grou
p,in
c. C
OPY
RIG
HT©
2017
w
ood
ley
arch
itect
ural
grou
p,in
c. A
LL R
IGHT
S RE
SERV
ED.
woo
dle
yarc
hite
ctur
algr
oup,
inc.
c o l o r a d o
2943 S. Pullman Street, Suite ASanta Ana, California 92705
V. 949.553.8919 F. 949.553.8909
ca l i fo rn ia
731 SouthPark Dr., Suite BLittleton, Colorado 80120
V. 303.683.7231 F. 303.683.2922
PROJECT NO.:DRAWN BY:
PLAN NUMBER
SHEET NUMBER
FIRST ISSUE:DATE:
CORRECTIONS 08/13/20181 PLAN CHECK
TWEL
VE
BRID
GES
TRA
MO
NTE
LIN
CO
LN,
CA
LIFO
RNIA
WO
OD
SID
E HO
MES
WDSCA-1702
MS
01/29/2019
07/06/2018
CORRECTIONS2 PLANNING08/13/2018
FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD
A4-A5-1
FOUR
2
3
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
LEFT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
3'-0
"
312
412
WINDOW AT OPT.HOME-PLUS
412
412
- ENHANCED
ADHERED STONEVENEER
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
RIGHT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
1'-0"
EQ. EQ.
3'-0
"
412 4
12
- ENHANCED
3'-0"
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
PARTIALLEFT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH
OPT. CENTER MEET SLIDER
- ENHANCED
7'-0
"
205-01AD
705-01AD
403-01AD
903-01AD
PARTIALRIGHT ELEVATION 'A'1/4" = 1/-0" MODERN SPANISH
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
312
- ENHANCED
THES
E DE
SIG
NS
AN
D DR
AW
ING
S A
RE C
ON
FIDE
NTIA
L, A
ND
THE
EXC
LUSI
VE P
ROPE
RTY
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
AN
D A
RE N
OT T
O B
E DI
SCLO
SED
WITH
OUT
THE
EXPR
ESS
PERM
ISSI
ON
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
THE
Y M
AY
NO
T BE
USED
OR
DUP
LIC
ATE
D W
ITHO
UT TH
E EX
PRES
S PE
RMIS
SIO
N O
F w
ood
ley
arch
itect
ural
grou
p,in
c. C
OPY
RIG
HT©
2017
w
ood
ley
arch
itect
ural
grou
p,in
c. A
LL R
IGHT
S RE
SERV
ED.
woo
dle
yarc
hite
ctur
algr
oup,
inc.
c o l o r a d o
2943 S. Pullman Street, Suite ASanta Ana, California 92705
V. 949.553.8919 F. 949.553.8909
ca l i fo rn ia
731 SouthPark Dr., Suite BLittleton, Colorado 80120
V. 303.683.7231 F. 303.683.2922
PROJECT NO.:DRAWN BY:
PLAN NUMBER
SHEET NUMBER
FIRST ISSUE:DATE:
CORRECTIONS 08/13/20181 PLAN CHECK
TWEL
VE
BRID
GES
TRA
MO
NTE
LIN
CO
LN,
CA
LIFO
RNIA
WO
OD
SID
E HO
MES
WDSCA-1702
MS
01/29/2019
07/06/2018
CORRECTIONS2 PLANNING08/13/2018
FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD
A4-A5-1E
FOUR
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
OPT. CABS
90°
MASTERBEDROOM
9'-0" CLG.CARPET
MASTERBATH9'-0" CLG.
HS
HERW.I.C.9'-0" CLG.CARPET
HISW.I.C.9'-0" CLG.CARPET
90°
OPT
2668
DR
OPTIONALSINK/CABS
LAU.9'-0" CLG.
HS
LOFT9'-0" CLG.CARPET
BEDROOM 39'-0" CLG.CARPET
BEDROOM 29'-0" CLG.CARPET
BEDROOM 49'-0" CLG.CARPET
BATH 29'-0" CLG.
HS
BATH 39'-0" CLG.
HS
OPT
2468
DR
E
E
E
HALL9'-0" CLG.CARPETOPT.
UPPERS
15°
SEE STANDARD PLAN FORINFORMATION NOT SHOWNHERE.SECOND FLOOR PLAN 'B'
1/4" = 1/-0" MID-CENTURY MODERN
5'-312"10'-11
2"6'-0"13'-712"12'-101
2"12'-1"
2'-612"5'-0"2'-7"3'-0"3'-0"3'-01
2"7'-6"3'-1"
2'-6"2'-6"2'-0"3'-6"2'-0"
2'-312" 7'-6" 2'-31
2"
3'-6" 2'-0"
1'-0
"18
'-0"
1'-0
"
11'-1
01 2"
3'-1
1"3'
-6"
4'-5
1 2"
6" 6" 6"6'
-01 2"
E
4050 SL
4050
SL
4020
FX
BELO
W
T3050 SH
3050 SH
2'-0"
3050 SH
3050 SH
3040SH
3040SH
SEE BASE PLAN A FORINFORMATION ONAREA WITHIN HATCH
PLAN FOURFIRST FLOOR = 2034 SQ. FT.
SECOND FLOOR = 1970 SQ. FT.
TOTAL = 4004 SQ. FT.
3-BAY GARAGE = 869 SQ. FT.
COVERED PORCH =
LOT COVERAGE =
MAX. LOT COVERAGE = 3938 SQ. FT.
OPT. OUTDOOR LIVING = +181 SQ. FT.
63 SQ. FT.
- B
2981 SQ. FT.
THES
E DE
SIG
NS
AN
D DR
AW
ING
S A
RE C
ON
FIDE
NTIA
L, A
ND
THE
EXC
LUSI
VE P
ROPE
RTY
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
AN
D A
RE N
OT T
O B
E DI
SCLO
SED
WITH
OUT
THE
EXPR
ESS
PERM
ISSI
ON
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
THE
Y M
AY
NO
T BE
USED
OR
DUP
LIC
ATE
D W
ITHO
UT TH
E EX
PRES
S PE
RMIS
SIO
N O
F w
ood
ley
arch
itect
ural
grou
p,in
c. C
OPY
RIG
HT©
2017
w
ood
ley
arch
itect
ural
grou
p,in
c. A
LL R
IGHT
S RE
SERV
ED.
woo
dle
yarc
hite
ctur
algr
oup,
inc.
c o l o r a d o
2943 S. Pullman Street, Suite ASanta Ana, California 92705
V. 949.553.8919 F. 949.553.8909
ca l i fo rn ia
731 SouthPark Dr., Suite BLittleton, Colorado 80120
V. 303.683.7231 F. 303.683.2922
PROJECT NO.:DRAWN BY:
PLAN NUMBER
SHEET NUMBER
FIRST ISSUE:DATE:
CORRECTIONS 08/13/20181 PLAN CHECK
TWEL
VE
BRID
GES
TRA
MO
NTE
LIN
CO
LN,
CA
LIFO
RNIA
WO
OD
SID
E HO
MES
WDSCA-1702
MS
01/29/2019
07/06/2018
CORRECTIONS2 PLANNING08/13/2018
FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD
A4-B2-2
FOUR
1. GLAZING SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH CRC SECTION R308.32. GLAZED PANELS REQUIRING SAFETY GLAZING SHALL BE IDENTIFIED WITH THE
WORD 'TEMPERED' OR 'TEMP' OR
GLAZING & FALL PROTECTION
SAFETY GLAZING
1. ALL GLAZING SHALL COMPLY WITH CRC SECTION R3082. ALL GLAZING SHALL BE DUAL PANE INSULATING GLASS U.N.O. IN THE TITLE 24
REPORT3. WINDOW CALLOUTS ARE AS FOLLOWS:
SL = SLIDER SH = SINGLE HUNGFG = FIXED GLASS CA = CASEMENT
1. WINDOW FALL PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITHSECTION R312.2.1 AND R312.2.2
2. IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW ISLOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR SURFACEBELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE AMINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICHTHE WINDOW IS LOCATED
WINDOW FALL PROTECTION
T
1. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE NOTLESS THAN ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING
EMERGENCY EGRESSEMERGENCY ESCAPE AND RESCUE OPENINGS
1. NOTE: EXTERIOR WINDOWS LABELED W/ AN SYMBOL SHALL BE DESIGNATEDFOR EMERGENCY EGRESS & RESCUE.
2. ESCAPE & RESCUE WINDOWS SHALL HAVE A MIN. NET CLEAR OPENABLE AREA OF5.7 SQ. FT. THE MIN. NET CLEAR OPENING SHALL BE NOT LESS THAN 24 INCHESHIGH AND 20 INCHES WIDE. WHEN WINDOWS ARE PROVIDED AS A MEANS OFESCAPE OR RESCUE, THEY SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOTGREATER THAN 44 INCHES MEASURED FROM THE FLOOR. THESE WINDOWS
3. ANY BARS, GRILLS GRATES OR OTHER SIMILAR DEVICES SHALL BE OPERATIONALFROM THE INSIDE OF ROOM WITHOUT THE USE OF KEYS OR TOOLS.
EEMERGENCY ESCAPE AND RESCUE WINDOWS
1. NOTE: EXTERIOR DOORS LABELED W/ AN SYMBOL SHALL BE DESIGNATED FOREMERGENCY EGRESS & RESCUE.
2. ESCAPE & RESCUE DOORS SHALL ARE PERMITTED TO BE SIDE HINGED OR A SLIDER.3. THE MINIMUM NET CLEAR HEIGHT OPENING FOR ANY DOOR THAT SERVES AS AN
EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE IN ACCORDANCE WITHSECTION R310.2.1
EEMERGENCY ESCAPE AND RESCUE DOORS
BATH AND SHOWER SPACES1. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED
SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITHNONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHTOF NOT LESS THAN 6 FEET ABOVE THE FLOOR. (SEC R307.2)
2. ALL GLASS SHOWER AND TUB/SHOWER DOORS SHALL BE TEMPERED.3. SHOWER AND TUB/SHOWER COMBINATIONS SHALL BE PROVIDED WITH
INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, ORCOMBINATION PRESSURE BALANCE/THERMOSTATIC MIXING VALVE TYPE THATPROVIDE SCALD AND THERMAL SHOCK PROTECTION. VALVES SHALL BEADJUSTED PER THE MANUFACTURER'S INSTRUCTIONS TO DELIVER A MAXIMUMMIXED WATER SETTING OF 120 DEGREES FAHRENHEIT.
4. PROVIDE 15" MINIMUM BETWEEN THE CENTER OF THE WATER CLOSET TO ANYSIDE WALL
5. PROVIDE 24" CLEAR SPACE IN FRONT OF ANY WATER CLOSET6. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS
SHALL BE PROVIDED NATURAL VENTILATION OR WITH MECHANICAL VENTILATIONCAPABLE OF 50 CFM EXHAUSTED DIRECTLY TO THE OUTSIDE (C.R.C. R303.3)
LAUNDRY ROOM NOTES1. UNLESS OTHERWISE PERMITTED OR REQUIRED BY THE DRYER MANUFACTURER'S
INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION,DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTALCOMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET, INCLUDING TWO 90DEGREE ELBOWS. A LENGTH OF 2 FEET SHALL BE DEDUCTED FOR EACH 90 DEGREEELBOW IN EXCESS OF TWO
2. PROVIDE 100 SQUARE INCHES OF MAKE-UP AIR TO ALL LAUNDRY ROOMS3. WASHER SPACE, PROVIDE RECESSED WATER AND WASTE4. AT 2ND FLOOR, PROVIDE "SMITTY" PAN UNDER WASHER WITH DRAIN TO OUTSIDE
SOFFIT SYMBOLSFLAT SOFFIT W/ TOP @ 9'-0" A.F.F. @ 10'-0" PL., @ 8'-0" A.F.F. @9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESS OTHERWISE NOTED
FLATTENED ARCH SOFFIT W/ TOP @ 9'-0" A.F.F. & SPRING POINT@ 8'-0" A.F.F. @ 10'-0" PL., TOP @ 8'-0" A.F.F & SPRING POINT @7'-0" A.F.F. @ 9'-0" PLATE OR TOP @ 7'-6" A.F.F & SPRING POINT@ 6'-6" A.F.F. @ 8'-0" PLATE UNLESS OTHERWISE NOTED
WALL LEGEND2X4 WALL
2X6 WALL
2X LOW WALL - HEIGHTPER FLOOR PLAN
FULL ARCH SOFFIT W/ TOP OF ARCH @ 9'-0" A.F.F. @ 10'-0" PL.,8'-0" A.F.F. @ 9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESSOTHERWISE NOTED
ELLIPTICAL ARCH SOFFIT AS NOTED IN PLAN OR ELEVATION
LEFT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
312
412
WINDOW AT OPT.HOME-PLUS
412 4
12
902-02AD
2x6 BARGERAFTER,
TYP.
802-02AD
ATWALL
1303-01AD
103-01AD
603-01AD
204-01AD
1X4TRIM
704-01AD
1204-01AD
205-01AD
705-01AD
1205-01AD
RIGHT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
1'-0"
6'-2"
1'-0"
412 4
12
1101-01AD
1301-01AD
402-02AD TYP.
105-01AD
1105-01AD
605-01AD
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
PARTIALLEFT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN
OPT. CENTER MEET SLIDER 402-02AD TYP.
PARTIALRIGHT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
312
902-02AD
2x6 BARGERAFTER,TYP.
THES
E DE
SIG
NS
AN
D DR
AW
ING
S A
RE C
ON
FIDE
NTIA
L, A
ND
THE
EXC
LUSI
VE P
ROPE
RTY
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
AN
D A
RE N
OT T
O B
E DI
SCLO
SED
WITH
OUT
THE
EXPR
ESS
PERM
ISSI
ON
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
THE
Y M
AY
NO
T BE
USED
OR
DUP
LIC
ATE
D W
ITHO
UT TH
E EX
PRES
S PE
RMIS
SIO
N O
F w
ood
ley
arch
itect
ural
grou
p,in
c. C
OPY
RIG
HT©
2017
w
ood
ley
arch
itect
ural
grou
p,in
c. A
LL R
IGHT
S RE
SERV
ED.
woo
dle
yarc
hite
ctur
algr
oup,
inc.
c o l o r a d o
2943 S. Pullman Street, Suite ASanta Ana, California 92705
V. 949.553.8919 F. 949.553.8909
ca l i fo rn ia
731 SouthPark Dr., Suite BLittleton, Colorado 80120
V. 303.683.7231 F. 303.683.2922
PROJECT NO.:DRAWN BY:
PLAN NUMBER
SHEET NUMBER
FIRST ISSUE:DATE:
CORRECTIONS 08/13/20181 PLAN CHECK
TWEL
VE
BRID
GES
TRA
MO
NTE
LIN
CO
LN,
CA
LIFO
RNIA
WO
OD
SID
E HO
MES
WDSCA-1702
MS
01/29/2019
07/06/2018
CORRECTIONS2 PLANNING08/13/2018
FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD
A4-B5-1
FOUR
3
LEFT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
312
412
WINDOW AT OPT.HOME-PLUS
412 4
12
- ENHANCED
205-01AD
705-01AD
1205-01AD
24"X
48"
24"X
48"
303-01AD
803-01AD
RIGHT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
1'-0"
6'-2"
1'-0"
412 4
12
- ENHANCED
205-01AD
705-01AD
1205-01AD
18"X
60"
18"X
60"
18"X
60"
18"X
60"
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
PARTIALLEFT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN
OPT. CENTER MEET SLIDER
- ENHANCED
403-01AD
903-01AD
205-01AD
705-01AD
1205-01AD
PARTIALRIGHT ELEVATION 'B'1/4" = 1/-0" MID-CENTURY MODERN
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
312
- ENHANCED
THES
E DE
SIG
NS
AN
D DR
AW
ING
S A
RE C
ON
FIDE
NTIA
L, A
ND
THE
EXC
LUSI
VE P
ROPE
RTY
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
AN
D A
RE N
OT T
O B
E DI
SCLO
SED
WITH
OUT
THE
EXPR
ESS
PERM
ISSI
ON
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
THE
Y M
AY
NO
T BE
USED
OR
DUP
LIC
ATE
D W
ITHO
UT TH
E EX
PRES
S PE
RMIS
SIO
N O
F w
ood
ley
arch
itect
ural
grou
p,in
c. C
OPY
RIG
HT©
2017
w
ood
ley
arch
itect
ural
grou
p,in
c. A
LL R
IGHT
S RE
SERV
ED.
woo
dle
yarc
hite
ctur
algr
oup,
inc.
c o l o r a d o
2943 S. Pullman Street, Suite ASanta Ana, California 92705
V. 949.553.8919 F. 949.553.8909
ca l i fo rn ia
731 SouthPark Dr., Suite BLittleton, Colorado 80120
V. 303.683.7231 F. 303.683.2922
PROJECT NO.:DRAWN BY:
PLAN NUMBER
SHEET NUMBER
FIRST ISSUE:DATE:
CORRECTIONS 08/13/20181 PLAN CHECK
TWEL
VE
BRID
GES
TRA
MO
NTE
LIN
CO
LN,
CA
LIFO
RNIA
WO
OD
SID
E HO
MES
WDSCA-1702
MS
01/29/2019
07/06/2018
CORRECTIONS2 PLANNING08/13/2018
FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD
A4-B5-1E
FOUR
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
OPT. CABS
90°
MASTERBEDROOM
9'-0" CLG.CARPET
MASTERBATH9'-0" CLG.
HS
HERW.I.C.9'-0" CLG.CARPET
HISW.I.C.9'-0" CLG.CARPET
90°
OPT
2668
DR
OPTIONALSINK/CABS
LAU.9'-0" CLG.
HS
LOFT9'-0" CLG.CARPET
BEDROOM 39'-0" CLG.CARPET
BEDROOM 29'-0" CLG.CARPET
BEDROOM 49'-0" CLG.CARPET
BATH 29'-0" CLG.
HS
BATH 39'-0" CLG.
HS
OPT
2468
DR
E
E
E
HALL9'-0" CLG.CARPETOPT.
UPPERS
15°
SEE STANDARD PLAN FORINFORMATION NOT SHOWNHERE.SECOND FLOOR PLAN 'C'
1/4" = 1/-0" MODERN PRAIRIE
3050 SH
3050 SH
2020 FX
2020 FX
2020 FX
2050 SH
2050 SH
2050 SH
EQ. HEAD/JAMB/ SILL
EQ. HEAD/JAMB/ SILL EQ. HEAD/
JAMB/ SILL
LINE OFSTONEVENEER
6'-512"9'-6"5'-51
2"13'-712"12'-101
2"12'-1"
11'-1
01 2"
1'-1012" 4'-61
2" 1'-11"
2'-0
"3'
-6"
3050SH
3050SH
3'-612"2'-6"2'-6"3'-61
2"
1'-0
"
1'-0
"18
'-0"
2'-0" 3'-6" 8'-112" 1'-101
2" 2'-612" 1'-01
2"2'-6" 4'-6" 2'-6"
6" 6"
1'-0
"6'
-01 2"
312"
6"
312"
SEE BASE PLAN A FORINFORMATION ONAREA WITHIN HATCH
E
4050 SL
4050 SL
1650
FX
1620
FX
BELO
W
T
3050
FX
3020
FX
BELO
W
T
4'-612"
PLAN FOURFIRST FLOOR =SECOND FLOOR =TOTAL =
3-BAY GARAGE = 869 SQ. FT.
COVERED PORCH =
LOT COVERAGE =
MAX. LOT COVERAGE = 3938 SQ. FT.
OPT. OUTDOOR LIVING = +181 SQ. FT.
30 SQ. FT.
- C
2961 SQ. FT.
2048 SQ. FT.
1969 SQ. FT.
4017 SQ. FT.
THES
E DE
SIG
NS
AN
D DR
AW
ING
S A
RE C
ON
FIDE
NTIA
L, A
ND
THE
EXC
LUSI
VE P
ROPE
RTY
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
AN
D A
RE N
OT T
O B
E DI
SCLO
SED
WITH
OUT
THE
EXPR
ESS
PERM
ISSI
ON
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
THE
Y M
AY
NO
T BE
USED
OR
DUP
LIC
ATE
D W
ITHO
UT TH
E EX
PRES
S PE
RMIS
SIO
N O
F w
ood
ley
arch
itect
ural
grou
p,in
c. C
OPY
RIG
HT©
2017
w
ood
ley
arch
itect
ural
grou
p,in
c. A
LL R
IGHT
S RE
SERV
ED.
woo
dle
yarc
hite
ctur
algr
oup,
inc.
c o l o r a d o
2943 S. Pullman Street, Suite ASanta Ana, California 92705
V. 949.553.8919 F. 949.553.8909
ca l i fo rn ia
731 SouthPark Dr., Suite BLittleton, Colorado 80120
V. 303.683.7231 F. 303.683.2922
PROJECT NO.:DRAWN BY:
PLAN NUMBER
SHEET NUMBER
FIRST ISSUE:DATE:
CORRECTIONS 08/13/20181 PLAN CHECK
TWEL
VE
BRID
GES
TRA
MO
NTE
LIN
CO
LN,
CA
LIFO
RNIA
WO
OD
SID
E HO
MES
WDSCA-1702
MS
01/29/2019
07/06/2018
CORRECTIONS2 PLANNING08/13/2018
FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD
A4-C2-2
FOUR
1. GLAZING SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH CRC SECTION R308.32. GLAZED PANELS REQUIRING SAFETY GLAZING SHALL BE IDENTIFIED WITH THE
WORD 'TEMPERED' OR 'TEMP' OR
GLAZING & FALL PROTECTION
SAFETY GLAZING
1. ALL GLAZING SHALL COMPLY WITH CRC SECTION R3082. ALL GLAZING SHALL BE DUAL PANE INSULATING GLASS U.N.O. IN THE TITLE 24
REPORT3. WINDOW CALLOUTS ARE AS FOLLOWS:
SL = SLIDER SH = SINGLE HUNGFG = FIXED GLASS CA = CASEMENT
1. WINDOW FALL PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITHSECTION R312.2.1 AND R312.2.2
2. IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW ISLOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR SURFACEBELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE AMINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICHTHE WINDOW IS LOCATED
WINDOW FALL PROTECTION
T
1. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE NOTLESS THAN ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING
EMERGENCY EGRESSEMERGENCY ESCAPE AND RESCUE OPENINGS
1. NOTE: EXTERIOR WINDOWS LABELED W/ AN SYMBOL SHALL BE DESIGNATEDFOR EMERGENCY EGRESS & RESCUE.
2. ESCAPE & RESCUE WINDOWS SHALL HAVE A MIN. NET CLEAR OPENABLE AREA OF5.7 SQ. FT. THE MIN. NET CLEAR OPENING SHALL BE NOT LESS THAN 24 INCHESHIGH AND 20 INCHES WIDE. WHEN WINDOWS ARE PROVIDED AS A MEANS OFESCAPE OR RESCUE, THEY SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOTGREATER THAN 44 INCHES MEASURED FROM THE FLOOR. THESE WINDOWS
3. ANY BARS, GRILLS GRATES OR OTHER SIMILAR DEVICES SHALL BE OPERATIONALFROM THE INSIDE OF ROOM WITHOUT THE USE OF KEYS OR TOOLS.
EEMERGENCY ESCAPE AND RESCUE WINDOWS
1. NOTE: EXTERIOR DOORS LABELED W/ AN SYMBOL SHALL BE DESIGNATED FOREMERGENCY EGRESS & RESCUE.
2. ESCAPE & RESCUE DOORS SHALL ARE PERMITTED TO BE SIDE HINGED OR A SLIDER.3. THE MINIMUM NET CLEAR HEIGHT OPENING FOR ANY DOOR THAT SERVES AS AN
EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE IN ACCORDANCE WITHSECTION R310.2.1
EEMERGENCY ESCAPE AND RESCUE DOORS
BATH AND SHOWER SPACES1. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED
SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITHNONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHTOF NOT LESS THAN 6 FEET ABOVE THE FLOOR. (SEC R307.2)
2. ALL GLASS SHOWER AND TUB/SHOWER DOORS SHALL BE TEMPERED.3. SHOWER AND TUB/SHOWER COMBINATIONS SHALL BE PROVIDED WITH
INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, ORCOMBINATION PRESSURE BALANCE/THERMOSTATIC MIXING VALVE TYPE THATPROVIDE SCALD AND THERMAL SHOCK PROTECTION. VALVES SHALL BEADJUSTED PER THE MANUFACTURER'S INSTRUCTIONS TO DELIVER A MAXIMUMMIXED WATER SETTING OF 120 DEGREES FAHRENHEIT.
4. PROVIDE 15" MINIMUM BETWEEN THE CENTER OF THE WATER CLOSET TO ANYSIDE WALL
5. PROVIDE 24" CLEAR SPACE IN FRONT OF ANY WATER CLOSET6. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS
SHALL BE PROVIDED NATURAL VENTILATION OR WITH MECHANICAL VENTILATIONCAPABLE OF 50 CFM EXHAUSTED DIRECTLY TO THE OUTSIDE (C.R.C. R303.3)
LAUNDRY ROOM NOTES1. UNLESS OTHERWISE PERMITTED OR REQUIRED BY THE DRYER MANUFACTURER'S
INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION,DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTALCOMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET, INCLUDING TWO 90DEGREE ELBOWS. A LENGTH OF 2 FEET SHALL BE DEDUCTED FOR EACH 90 DEGREEELBOW IN EXCESS OF TWO
2. PROVIDE 100 SQUARE INCHES OF MAKE-UP AIR TO ALL LAUNDRY ROOMS3. WASHER SPACE, PROVIDE RECESSED WATER AND WASTE4. AT 2ND FLOOR, PROVIDE "SMITTY" PAN UNDER WASHER WITH DRAIN TO OUTSIDE
SOFFIT SYMBOLSFLAT SOFFIT W/ TOP @ 9'-0" A.F.F. @ 10'-0" PL., @ 8'-0" A.F.F. @9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESS OTHERWISE NOTED
FLATTENED ARCH SOFFIT W/ TOP @ 9'-0" A.F.F. & SPRING POINT@ 8'-0" A.F.F. @ 10'-0" PL., TOP @ 8'-0" A.F.F & SPRING POINT @7'-0" A.F.F. @ 9'-0" PLATE OR TOP @ 7'-6" A.F.F & SPRING POINT@ 6'-6" A.F.F. @ 8'-0" PLATE UNLESS OTHERWISE NOTED
WALL LEGEND2X4 WALL
2X6 WALL
2X LOW WALL - HEIGHTPER FLOOR PLAN
FULL ARCH SOFFIT W/ TOP OF ARCH @ 9'-0" A.F.F. @ 10'-0" PL.,8'-0" A.F.F. @ 9'-0" PL. OR 7'-6" A.F.F. @ 8'-0" PL. UNLESSOTHERWISE NOTED
ELLIPTICAL ARCH SOFFIT AS NOTED IN PLAN OR ELEVATION
LEFT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
1'-0"312
COVERED PORCHPARTIAL LEFT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
WINDOW AT OPT.HOME-PLUS
412
412
412
412
412
412 4
12
402-02AD TYP.
1303-01AD
103-01AD
603-01AD
404-01AD
1X4WDTRIM
904-01AD
1204-01AD
804-01AD
1X4WDTRIM
RIGHT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
1'-0"
EQ. EQ.
412 4
12
412
1101-01AD
1201-01AD
1302-02AD
402-02AD TYP.
105-01AD
1105-01AD
605-01AD
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
PARTIALLEFT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE
OPT. CENTER MEET SLIDER 402-02AD TYP.
PARTIALRIGHT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
312
412
THES
E DE
SIG
NS
AN
D DR
AW
ING
S A
RE C
ON
FIDE
NTIA
L, A
ND
THE
EXC
LUSI
VE P
ROPE
RTY
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
AN
D A
RE N
OT T
O B
E DI
SCLO
SED
WITH
OUT
THE
EXPR
ESS
PERM
ISSI
ON
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
THE
Y M
AY
NO
T BE
USED
OR
DUP
LIC
ATE
D W
ITHO
UT TH
E EX
PRES
S PE
RMIS
SIO
N O
F w
ood
ley
arch
itect
ural
grou
p,in
c. C
OPY
RIG
HT©
2017
w
ood
ley
arch
itect
ural
grou
p,in
c. A
LL R
IGHT
S RE
SERV
ED.
woo
dle
yarc
hite
ctur
algr
oup,
inc.
c o l o r a d o
2943 S. Pullman Street, Suite ASanta Ana, California 92705
V. 949.553.8919 F. 949.553.8909
ca l i fo rn ia
731 SouthPark Dr., Suite BLittleton, Colorado 80120
V. 303.683.7231 F. 303.683.2922
PROJECT NO.:DRAWN BY:
PLAN NUMBER
SHEET NUMBER
FIRST ISSUE:DATE:
CORRECTIONS 08/13/20181 PLAN CHECK
TWEL
VE
BRID
GES
TRA
MO
NTE
LIN
CO
LN,
CA
LIFO
RNIA
WO
OD
SID
E HO
MES
WDSCA-1702
MS
01/29/2019
07/06/2018
CORRECTIONS2 PLANNING08/13/2018
FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD
A4-C5-1
FOUR
2
3
LEFT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
1'-0"312
COVERED PORCHPARTIAL LEFT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
WINDOW AT OPT.HOME-PLUS
412
412
412
412
412
412 4
12
- ENHANCED
502-02AD
205-01AD
705-01AD
1205-01AD
305-01AD
805-01AD
1305-01AD
24"X
48"
24"X
48"
303-01AD
803-01AD
4" LAP SIDING BYLP SMARTSIDE
RIGHT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
1'-0"
EQ. EQ.
412 4
12
412
- ENHANCED
205-01AD
705-01AD
1205-01AD
COMPOSITESHUTTERS
307-01AD
18"X
60"
18"X
60"
18"X
60"
18"X
60"
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
PARTIALLEFT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE
OPT. CENTER MEET SLIDER
- ENHANCED
403-01AD
903-01AD
205-01AD
705-01AD
1205-01AD
PARTIALRIGHT ELEVATION 'C'1/4" = 1/-0" MODERN PRAIRIE
8'-0
"
FIN. FLR.T.O. GRADE
9'-1
"
T.O. WIN.
T.O. PLATE
8'-0
"
FIN. FLR.
9'-1
"
T.O. WIN.
T.O. PLATE
312
412
- ENHANCED
THES
E DE
SIG
NS
AN
D DR
AW
ING
S A
RE C
ON
FIDE
NTIA
L, A
ND
THE
EXC
LUSI
VE P
ROPE
RTY
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
AN
D A
RE N
OT T
O B
E DI
SCLO
SED
WITH
OUT
THE
EXPR
ESS
PERM
ISSI
ON
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
THE
Y M
AY
NO
T BE
USED
OR
DUP
LIC
ATE
D W
ITHO
UT TH
E EX
PRES
S PE
RMIS
SIO
N O
F w
ood
ley
arch
itect
ural
grou
p,in
c. C
OPY
RIG
HT©
2017
w
ood
ley
arch
itect
ural
grou
p,in
c. A
LL R
IGHT
S RE
SERV
ED.
woo
dle
yarc
hite
ctur
algr
oup,
inc.
c o l o r a d o
2943 S. Pullman Street, Suite ASanta Ana, California 92705
V. 949.553.8919 F. 949.553.8909
ca l i fo rn ia
731 SouthPark Dr., Suite BLittleton, Colorado 80120
V. 303.683.7231 F. 303.683.2922
PROJECT NO.:DRAWN BY:
PLAN NUMBER
SHEET NUMBER
FIRST ISSUE:DATE:
CORRECTIONS 08/13/20181 PLAN CHECK
TWEL
VE
BRID
GES
TRA
MO
NTE
LIN
CO
LN,
CA
LIFO
RNIA
WO
OD
SID
E HO
MES
WDSCA-1702
MS
01/29/2019
07/06/2018
CORRECTIONS2 PLANNING08/13/2018
FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD
A4-C5-1E
FOUR
SECOND FLOOR PLAN 'A'1/4" = 1/-0" MODERN SPANISH
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
OPT. CABS
90°
90°
OPT
2668
DR
OPTIONALSINK/CABS
OPT
2468
DR
OPT.UPPERS
15°
UTILITY -
HE
CEILING LIGHTCENTERED INROOM.PRE-WIRE FORFAND
+44"GFCI
3V
3
V H
WPHE
HE
CEILING LIGHTCENTERED INROOM.PRE-WIRE FORFAN
D
+44"GFCI
WPHE
HE
CEILING LIGHTCENTERED INROOM.PRE-WIRE FORFAN
CAT5RG6
S
S
S
S
S CM
CAT5RG6
PRE-WIREFOR FAN
HECENTERED
D
HE
HE
3'-0
"6'
-0"
V
4'-0"
+44"GFCI
+32"GFCI
+32"GFCI
+44"GFCI
WPHEWP
HE
HECENTERED
V
H
V H V
HE
3V AT OPT. DOOR
+36"220VGFCI
FG
+54"GFCI
C.W.
H.W.
+44"GFCI
C
HE
HE
V
HE HE HE
HE
HE
HE
HE HE
3
3
3
33
TO STAIRLIGHT SWITCHBELOW
D
HE
HE
TO SWITCHBELOW
CENTER ONSLIDER BELOW
4'-0
"8'
-9"
1'-9"
4'-5
"6'
-6"
4'-2"9'-0"
9'-0
"
1'-9"
4'-6" 4'-6"2'-512"
MASTERBEDROOM
MASTERBATH
HERW.I.C.
HISW.I.C.
LAU.
LOFT
BEDROOM 3
BEDROOM 2
BEDROOM 4
BATH 2
BATH 3
HALL
S
V
PROVIDE CAT5e CABLE FROMSTRUCTURED WIRE PANEL TO ALLTHERMOSTATS & ELECTRICALSERVICE PANELHOME RUN BOX FORSTRUCTURED WIRING(LOW VOLTAGE) - 1"CONDUIT
CAT5VOICE/DATA
HE HE
HE HE
3'-6"
3'-6
"3'-6"
6'-0
"
THES
E DE
SIG
NS
AN
D DR
AW
ING
S A
RE C
ON
FIDE
NTIA
L, A
ND
THE
EXC
LUSI
VE P
ROPE
RTY
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
AN
D A
RE N
OT T
O B
E DI
SCLO
SED
WITH
OUT
THE
EXPR
ESS
PERM
ISSI
ON
OF
woo
dle
yar
chite
ctur
algr
oup,
inc.
THE
Y M
AY
NO
T BE
USED
OR
DUP
LIC
ATE
D W
ITHO
UT TH
E EX
PRES
S PE
RMIS
SIO
N O
F w
ood
ley
arch
itect
ural
grou
p,in
c. C
OPY
RIG
HT©
2017
w
ood
ley
arch
itect
ural
grou
p,in
c. A
LL R
IGHT
S RE
SERV
ED.
woo
dle
yarc
hite
ctur
algr
oup,
inc.
c o l o r a d o
2943 S. Pullman Street, Suite ASanta Ana, California 92705
V. 949.553.8919 F. 949.553.8909
ca l i fo rn ia
731 SouthPark Dr., Suite BLittleton, Colorado 80120
V. 303.683.7231 F. 303.683.2922
PROJECT NO.:DRAWN BY:
PLAN NUMBER
SHEET NUMBER
FIRST ISSUE:DATE:
CORRECTIONS 08/13/20181 PLAN CHECK
TWEL
VE
BRID
GES
TRA
MO
NTE
LIN
CO
LN,
CA
LIFO
RNIA
WO
OD
SID
E HO
MES
WDSCA-1702
MS
01/29/2019
07/06/2018
CORRECTIONS2 PLANNING08/13/2018
FRAMING WALK REVISIONS3 CLIENT REVISIONS/TBD
1. PER SECTION R309.8, NEWLY CONSTRUCTED ONE AND TWOFAMILY DWELLINGS AND TOWNHOUSES WITH ATTACHED PRIVATEGARAGES SHALL COMPLY WITH EV INFRASTRUCTUREREQUIREMENTS IN ACCORDANCE WITH CALIFORNIA GREENBUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.1.
2. FOR EACH DWELLING UNIT, INSTALL A LISTED RACEWAY TOACCOMMODATE A DEDICATED 208/240 VOLT BRANCH CIRCUIT.RACEWAYS ARE REQUIRED TO BE CONTINUOUS AT ENCLOSED,INACCESSIBLE, OR CONCEALED AREAS AND SPACES
3. THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALLIDENTIFY THE OVERCURRENT PROTECTIVE DEVICE SPACE(S)RESERVED FOR FUTURE EV CHARGING AS "EV CAPABLE". THERACEWAY TERMINATION LOCATION SHALL BE PERMANENTLYAND VISIBLY MARKED AS "EV CAPABLE"
ELECTRIC VEHICLE NOTES
GENERAL UTILITY NOTES1. ELECTRICAL, MECHANICAL AND PLUMBING SYSTEMS ARE SHOWN FOR
INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THECONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION &PLACEMENT. ALL HEIGHTS SHOWN ARE TO CENTERLINE OF FIXTURE.
2. PANEL BOARDS ARE NOT ALLOWED IN STORAGE CLOSETS ORBATHROOMS
3. ELECTRICAL EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING LAB4. ELECTRICAL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS OF
MORE THAN 50 VOLTS SHALL HAVE A POSITIVE MEANS OF DISCONNECTADJACENT TO AND IN SIGHT FROM THE EQUIPMENT SERVED.
5. ALL FIXTURES INSTALLED IN DAMP OR WET LOCATIONS SHALL BE MARKED'SUITABLE FOR WET LOCATIONS'
6. CLOTHES DRYERS TO HAVE 4-WIRE GROUNDED ELECTRICAL OUTLET7. BOND GROUNDING ELECTRODE TO METAL GAS AND WATER PIPING,
POINTS OF ATTACHMENT OF THE BONDING JUMPER(S) TO BEACCESSIBLE
8. ARC FAULT INTERRUPTER CIRCUITS: ALL 120-VOLT, SINGLE PHASE, 15 AND20 AMPRE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED INDWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVINGROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, ORSIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTEDARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE, INSTALLED TOPROVIDE PROTECTION OF THE BRANCH CIRCUIT.
LOW VOLTAGE NOTES1. CARBON MONOXIDE DETECTORS TO BE 110 VOLT W/ BATTERY BACKUP
AND SHALL BE INTERCONNECTED SO THAT IF AN ALARM SOUNDED INONE ROOM, IT SHALL BE SOUNDED IN ALL THE OTHERS, & SHALL BELOCATED ON EVERY LEVEL OF THE DWELLING AND IN THE IMMEDIATEVICINITY OF THE BEDROOMS, PER CRC R314 & R315.
2. SMOKE DETECTORS TO BE 110 VOLT W/ BATTERY BACKUP AND SHALL BEINTERCONNECTED SO THAT IF AN ALARM SOUNDED IN ONE ROOM, ITSHALL BE SOUNDED IN ALL THE OTHERS, & SHALL BE LOCATED ON EVERYLEVEL OF THE DWELLING, IN THE IMMEDIATE VICINITY OF THE BEDROOMSAND IN EACH SLEEPING ROOM, PER CRC R314 & R315.
3. SMOKE ALARMS OR SMOKE DETECTORS SHALL BE INSTALLED A MINIMUMOF 20 FEET HORIZONTAL DISTANCE FROM A PERMANENTLY INSTALLEDCOOKING APPLIANCE WITH THE EXCEPTION OF IONIZATION SMOKEALARMS WITH AN ALARM-SILENCING SWITCH OR PHOTOELECTRIC SMOKEALARMS, WHICH SHALL BE PERMITTED TO BE INSTALLED 10 FEET ORGREATER FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. (NFPA72 SECTION 29.8.3.4)
MECHANICAL NOTES1. FUEL BURNING EQUIPMENT SHALL BE EQUIPPED WITH AN APPROVED
AUTOMATIC MEANS WHICH WILL SHUT OFF FUEL SUPPLY TO EQUIPMENTIN THE EVENT OF IGNITION OR FLAME FAILURE.
2. BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BEDUCTED TO TERMINATE OUTSIDE THE BUILDING. UNLESS FUNCTIONINGAS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANSMUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILYACCESSIBLE
3. EXHAUST FANS WITH A COMMON EXHAUST SHALL BE PROVIDED WITH ABACKDRAFT DAMPER TO PREVENT RECIRCULATION
4. MECHANICAL WHOLE HOUSE VENTILATION TO BE PROVIDED, INCOMPLIANCE WITH ASHRAE 62.2 PER 2016 ENERGY CODE
5. EXHAUST FAN FOR LOCAL AND WHOLE HOUSE VENTILATION (CFM'S PERTABLE 4-7 OF THE 2016 RESIDENTIAL COMPLIANCE MANUAL).
6. EXHAUST FANS FOR LOCAL VENTILATION MUST BE RATED AT A MINIMUMOF 50 CFM AND PROPERLY DUCTED TO THE OUTSIDE PER ASHRAE 622,TABLE 7-1. FANS IN WET LOCATIONS TO HAVE HUMIDISTAT SWITCH.
7. RANGE HOOD VENTILATION FOR THE KITCHEN MUST BE RATED AT AMINIMUM OF 100 CFM AT WORKING SPEED AND PROPERLY DUCTED TOTHE OUTSIDE PER ASHRAE 622, TABLE 7-1.
8. SWITCH FOR CONTINUOUS FAN TO BE LABELED OR OTHER APPROVEDMEANS BY BUILDING DEPARTMENT.
9. FOR CONTINUOUS VENTILATION, EXHAUST FAN MUST BE RATED 1.0 SONEOR LESS. IF INTERMITTENT VENTILATION IS USED, THE EXHAUST FAN MUSTBE RATED 3.O SONES OR LESS.
ELECTRICAL NOTES1. PROVIDE GFCI PROTECTED OUTLETS AT THE FOLLOWING LOCATIONS:
BATHROOMS, GARAGES EXCEPT THOSE THAT ARE NOT READILYACCESSIBLE, OUTDOORS, CRAWL SPACES LOCATED AT OR BELOWGRADE LEVEL, UNFINISHED BASEMENTS, ALL KITCHEN COUNTERTOPS,AND WITHIN 6'-0" OF LAUNDRY OR WET BAR SINKS
2. RECEPTACLE OUTLETS AT KITCHEN COUNTERTOPS SHALL BE SPACED SOTHAT NO PORTION OF THE COUNTERTOP IS FURTHER THAN 24" FROM ANOUTLET
3. WALL OUTLETS IN HABITABLE ROOMS SHALL BE SPACED SO THAT NOPOINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6'-0"FROM AN OUTLET AND THAT NO WALL 2' OR GREATER DOES NOT HAVEAN OUTLET
4. WEATHER PROTECT OUTDOOR RECEPTACLE. RECEPTACLES LOCATED INA WET LOCATION SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOFWHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. AN OUTLETBOX HOOD INSTALLED FOR THIS PURPOSE SHALL BE LISTED AND SHALL BEIDENTIFIED AS "EXTRA DUTY"
5. PROVIDE ONE ELECTRICAL OUTLET IN HALLWAYS AT LEAST 10'-0" LONG6. OUTLET BOXES FOR CEILING FANS SHALL BE LISTED SPECIFICALLY FOR
THAT USE AND BE DESIGNED TO SUPPORT 70 LB PADDLE FANS7. PROVIDE SWITCH CONTROLLED LIGHTING OUTLETS AT ALL ROOMS,
GARAGES AND OUTDOOR ENTRANCES8. NOT USED9. RECESSED LIGHTING IN INSULATED CLG'S SHALL BE RATED BY U.L.10. BATHROOM OUTLETS SHALL BE SERVED BY A SEPARATE 20 AMP CIRCUIT
HOWEVER, THIS CIRCUIT IS PERMITTED TO SUPPLY THE REQUIREDRECEPTACLES IN MORE THAN ONE BATHROOM
11. ALL RECEPTACLES THAT SERVE THE COUNTER AREA SHALL BE GFIPROTECTED IN KITCHEN AREA
12. PROVIDE MIN. TWO (2) 20-AMP SMALL APPLIANCE BRANCH CIRCUITSFOR KITCHEN AND SHALL HAVE NO OTHER OUTLETS
13. BATHROOM CIRCUITS SHALL HAVE NO OTHER OUTLETS, MINIMUM20-AMP CIRCUIT
14. PROVIDED AT GROUND FAULT CIRCUIT INTERRUPTER AT KITCHENS, BATHROOMS, GARAGES AND LAUNDRY ROOMS
15. ALL 125-VOLT, 15- AND 20- AMPERE RECEPTACLES TO BE LISTEDTAMPER-RESISTANT RECEPTACLES IN ALL AREAS SPECIFIED PER CECSECTION 210.52. (CEC 406.11)
16. PROVIDE 110V SERVICE OUTLET SWITCH, FLUORESCENT LIGHT W/VACANCY SENSOR FOR ATTIC ACCESS AT FAU LOCATION.
17. ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCEWITH TABLE 150.0-A (CALIFORNIA ENERGY CODE - 150.0 K 1. A)
PLUMBING NOTES1. OVER AND UNDER GAS AND ELECTRICAL METERS ARE NOT ALLOWED.2. WHEN SINGLE SHOWER FIXTURES ARE SERVED BY MORE THAN ONE
SHOWERHEAD, THE COMBINED FLOW RATE OF ALL SHOWERHEADSSHALL NOT EXCEED THE MAXIMUM FLOW RATES SPECIFIED IN THE 2016CALIFORNIA GREEN CODE
1. THE MAIN SERVICE PANEL SHALL HAVE A MINIMUM BUSBARRATING OF 200 AMPS.
2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVEDSPACE TO ALLOW FOR INSTALLATION OF A DOUBLE POLE CIRCUITBREAKER FOR FUTURE SOLAR ELECTRIC INSTALLATION. THERESERVED SPACE SHALL BE POSITIONED AT THE OPPOSITE (LOAD)END OF THE INPUT FEEDER LOCATION OR MAIN CIRCUITLOCATION AND SHALL BE PERMANENTLY MARKED AS "FORFUTURE SOLAR ELECTRIC".
3. PROVIDE PATHWAY FOR ROUTING PLUMBING FROM SOLAR ZONETO WATER HEATING SYSTEM
4. PROVIDE PATHWAY FOR ROUTING CONDUIT FROM SOLAR ZONETO MAIN SERVICE PANEL.
FUTURE SOLAR NOTES
UTILITY SYMBOLS
+XX"
C
120V DUPLEX CONVENIENCE TAMPER RESISTANT RECEPTACLE W/ARC FAULT CIRCUIT INTERRUPT, INSTALLED 12" ABOVE FF (U.O.N.)
120V 4-PLEX CONVENIENCE TAMPER RESISTANT RECEPTACLE
120V FLOOR TYPE TAMPER RESISTANT RECEPTACLE W/ COVER
120V DUPLEX CONVENIENCE TAMPER RESISTANT RECEPTACLE, 1/2HOT, THE OTHER HALF SWITCH CONTROLLED
220V SINGLE CONVENIENCE TAMPER RESISTANT RECEPTACLEINSTALLED 12" ABOVE FINISHED FLOOR (U.O.N.)
TWO-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVECOUNTER (U.O.N.)
MANUAL ON, TWO-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR8" ABOVE COUNTER (U.O.N.) W/ VACANCY SENSOR
TWO-POLE DIMMER LIGHT SWITCH AT 42" ABOVE FLOOR OR 8"ABOVE COUNTER (U.O.N.)
THREE-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVECOUNTER (U.O.N.)
FOUR-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVECOUNTER (U.O.N.)
HUMIDISTAT
PHONE JACK (CAT5) INSTALLED 12" ABOVE FINISHED FLOOR OR 8"ABOVE COUNTER (U.N.O.)
TELEVISION (RG6) / PHONE JACK (CAT5) INSTALLED 12" ABOVEFINISHED FLOOR OR 8" ABOVE COUNTER (U.N.O.)
WALL MOUNTED LIGHT FIXTURE, SEE PLANS FOR HEIGHT
SURFACE MOUNTED CEILING LIGHT FIXTURE
RECESSED LIGHT FIXTURE
HANGING LIGHT FIXTURE
RECESSED COMBINATION EXHAUST FAN/LIGHT, SWITCHCONTROLLED
CONTINUOUS FAN COMPLIANT WITH ASHRAE 62.2. VENT TOEXTERIOR WITH 6" DUCT
LOCAL EXHAUST FAN COMPLIANT WITH ASHRAE 62.2. MIN. 50 CFMMAX 3 SONE OR EXCEEDS 400 CFM
RECESSED "EYE-BALL" CAN LIGHT FIXTURE
FUEL GAS OUTLET FUEL
GAS LOOSE KEY VALVE
PUSH BUTTON FOR GARAGE DOOR OPENER OR CHIMES
JUNCTION BOX, W/ COVER OR ADAPTER AS REQUIRED (VOLTAGEAS INDICATED)
THERMOSTAT VERIFY LOCATION W/ HVAC LAYOUT
HOSE BIBB
HOSE BIBB WITH SHUT OFF VALVE
ILLUMINATED ADDRESS NUMBERS
SMOKE DETECTOR, REFER TO LOW VOLTAGE NOTES
SMOKE/CARBON MONOXIDE DETECTOR COMBO, REFER TO LOWVOLTAGE NOTES
CARBON MONOXIDE DETECTOR, REFER TO LOW VOLTAGE NOTES
DOOR CHIMES, SEE PLANS FOR HEIGHT
UNDER CABINET, SURFACE MOUNTED 24" LIGHT AS REQUIRED BYCALIFORNIA TITLE 24, 40 LUMENS/WATT
SURFACE MOUNTED CEILING FAN, SWITCH CONTROLLED W/OPTIONAL INCANDESCENT LIGHT
12"X48" SINGLE TUBE OR 24'X48" DOUBLE TUBE CEILING MOUNTEDFIXTURE, SWITCH CONTROLLED, 40 LUMENS/WATT
V
D
3
4
H
RG6
SYMBOL LEGEND:
WP = WATER PROOFVP = VAPOR PROOFGFCI = GROUND FAULT CIRCUIT INTERRUPTERF = FLUORESCENTLED = LIGHT EMITTING DIODEHE = HIGH EFFICACY
B
J
T
SOV
S
SCM
CM
FOUR
AE4-2
3
3