GREENLINE GROUP PTY LTD N.T.S 22.03.2019ISSUED FOR …

5
GREENLINE GROUP PTY LTD 3 Ball Place, WAGGA WAGGA NSW 2650 P: 02 6938 1000 | E: [email protected] ABN: 47 113 674 561 ALL DIMENSIONS IN mm U.N.O 0 DECIMAL PLACES ±1 ±1° 1 DECIMAL PLACE ±0.5 ±0.5° DRAWING NUMBER REFERENCE DRAWING TITLE REV DATE REVISION DETAILS DRN CHK ENG APP A DRAWING TOLERANCES: CLIENT DETAILS QUASAR CONSTRUCTIONS EASTERN CREEK SHOPPING CENTRE 179 ROOTY HILL RD S EASTERN CREEK NSW 2766 PROPOSED CAR PARK SHADE STRUCTURES DESIGN CONSIDERATIONS SCALE A3 SHEET DRAWING NUMBER REV 2 OF 6 C PROJECT NUMBER S-6776 22.03.2019 ISSUED FOR REVIEW HTM FP S-6776-DG-500-001.2 B 16.05.2019 RE-ISSUED FOR REVIEW FP C 11.07.2019 RE-ISSUED FOR REVIEW FP CONSIDERATIONS IN DESIGN 179 ROOTY HILL RD S, EASTERN CREEK NSW 2766 RESIDENTIAL SUBURB IN BUILT UP AREA NOTES: IT IS THE RESPONSIBILITY OF THE CLIENT TO CONFIRM ALL DETAILS ON THIS PAGE VARIATIONS MAY APPLY IF DETAILS ARE FOUND TO BE INCORRECT WIND REGION: A2 CORROSIVITY REGION: C3 LOT 2, SECTION A, DP8681 AND LOT 7, DP830836 GROUND CONDITIONS: DESIGN TO ALLOW FOR CONDITIONS AS PER GEOTECH BY PSM CONSULT PTY LIMITED (REF# PSM2802-103L), RECEIVED FROM QUASAR ON 18/06/2019 ROCK SAND FILL WATER TABLE NONE ADVISED NONE ADVISED NONE ADVISED NONE ADVISED ALLOWANCE MADE FOR 100KPA CLAY SOILS UNDERGROUND SERVICES: NONE ADVISED OVERHEAD SERVICES: NONE ADVISED USE OF AREA: RETAIL CAR PARK NO FENCED: NON-ACCESSIBLE ACCESSIBLE: HERITAGE: NONE ADVISED ENVIRONMENTAL: NONE ADVISED FLOOD: NONE ADVISED HEIGHTS APPROXIMATELY 2.5M HIGH UNDER LOWEST POINT. SURFACES: GREENLINE HAS NOT INCLUDED ANY ALLOWANCE FOR SURFACE PROTECTION OR REPAIR. SURFACES: SURFACING TO BE COMPLETED AFTER OUR FOOTINGS ARE INSTALLED SURFACE PROTECTION & REPAIR: NOT REQUIRED ACCESS: CLEAR ACCESS TO SITE. TEMPORARY FENCING: 1800MM CONSTRUCTION FENCING BY HEAD CONTRACTOR METHODOLOGY OR STAGING: NO STAGING WITH PHASES (I.E. FOOTINGS COMPLETED IN ONE GO, STRUCTURES LIKEWISE) OTHER SCOPE ITEMS: LIGHTING: PROVISION FOR LIGHTING (PENETRATIONS ONLY) WITHIN OUR STRUCTURES - LIGHTING SCOPE ITSELF COMPLETED BY OTHERS FIRE: NONE ADVISED STRUCTURE DESIGN & DETAILING CADASTRE: N.T.S I HAVE REVIEWED THESE DRAWINGS AND CONFIRM THAT THE DESIGN IS IN ACCORDANCE WITH MY EXPECTATIONS AND IS CONSISTENT WITH THE SCOPE OF WORK AGREED. SIGNED: NAME: DATE: CLIENT APPROVAL APPROVAL PENDING NOT FOR CONSTRUCTION

Transcript of GREENLINE GROUP PTY LTD N.T.S 22.03.2019ISSUED FOR …

GREENLINE GROUP PTY LTD3 Ball Place, WAGGA WAGGA NSW 2650P: 02 6938 1000 | E: [email protected]: 47 113 674 561

ALL DIMENSIONS IN mm U.N.O

0 DECIMAL PLACES ±1 ±1°

1 DECIMAL PLACE ±0.5 ±0.5°

DRAWING NUMBER REFERENCE DRAWING TITLE REV DATE REVISION DETAILS DRN CHK ENG APP

A

DRAWING TOLERANCES: CLIENT DETAILS

QUASAR CONSTRUCTIONSEASTERN CREEK SHOPPING CENTRE

179 ROOTY HILL RD SEASTERN CREEK NSW 2766

PROPOSED CAR PARK SHADE STRUCTURESDESIGN CONSIDERATIONSSCALE

A3SHEET DRAWING NUMBER REV

2 OF 6 C

PROJECT NUMBER

S-677622.03.2019 ISSUED FOR REVIEW HTM FP

S-6776-DG-500-001.2

B 16.05.2019 RE-ISSUED FOR REVIEW FP

C 11.07.2019 RE-ISSUED FOR REVIEW FP

CONSIDERATIONS IN DESIGN

179 ROOTY HILL RD S, EASTERN CREEK NSW 2766RESIDENTIAL SUBURB IN BUILT UP AREA

NOTES: IT IS THE RESPONSIBILITY OF THE CLIENT TO CONFIRM ALL DETAILS ON THIS PAGEVARIATIONS MAY APPLY IF DETAILS ARE FOUND TO BE INCORRECT

WIND REGION: A2CORROSIVITY REGION: C3

LOT 2, SECTION A, DP8681 AND LOT 7, DP830836

GROUND CONDITIONS: DESIGN TO ALLOW FOR CONDITIONS AS PER GEOTECH BY PSM CONSULT PTY LIMITED (REF# PSM2802-103L), RECEIVED FROM QUASAR ON 18/06/2019ROCKSANDFILLWATER TABLE

NONE ADVISEDNONE ADVISEDNONE ADVISEDNONE ADVISED

ALLOWANCE MADE FOR 100KPA CLAY SOILS

UNDERGROUND SERVICES: NONE ADVISEDOVERHEAD SERVICES: NONE ADVISED

USE OF AREA: RETAIL CAR PARKNOFENCED:NON-ACCESSIBLEACCESSIBLE:

HERITAGE: NONE ADVISED

ENVIRONMENTAL: NONE ADVISED

FLOOD: NONE ADVISED

HEIGHTSAPPROXIMATELY 2.5M HIGH UNDER LOWEST POINT.

SURFACES: GREENLINE HAS NOT INCLUDED ANY ALLOWANCE FOR SURFACE PROTECTION OR REPAIR. SURFACES: SURFACING TO BE COMPLETED AFTER OUR FOOTINGS ARE INSTALLEDSURFACE PROTECTION & REPAIR: NOT REQUIRED

ACCESS: CLEAR ACCESS TO SITE.TEMPORARY FENCING: 1800MM CONSTRUCTION FENCING BY HEAD CONTRACTOR

METHODOLOGY OR STAGING: NO STAGING WITH PHASES (I.E. FOOTINGS COMPLETED IN ONE GO, STRUCTURES LIKEWISE)

OTHER SCOPE ITEMS: LIGHTING: PROVISION FOR LIGHTING (PENETRATIONS ONLY) WITHIN OUR STRUCTURES - LIGHTING SCOPE ITSELF COMPLETED BY OTHERS

FIRE: NONE ADVISED

STRUCTURE DESIGN & DETAILING

CADASTRE:

N.T.S

I HAVE REVIEWED THESE DRAWINGSAND CONFIRM THAT THE DESIGN IS INACCORDANCE WITH MYEXPECTATIONS AND IS CONSISTENTWITH THE SCOPE OF WORK AGREED.

SIGNED:

NAME:

DATE:

CLIENT APPROVAL

APPROVAL PENDINGNOT FOR CONSTRUCTION

GREENLINE GROUP PTY LTD3 Ball Place, WAGGA WAGGA NSW 2650P: 02 6938 1000 | E: [email protected]: 47 113 674 561

ALL DIMENSIONS IN mm U.N.O

0 DECIMAL PLACES ±1 ±1°

1 DECIMAL PLACE ±0.5 ±0.5°

DRAWING NUMBER REFERENCE DRAWING TITLE REV DATE REVISION DETAILS DRN CHK ENG APP

A

DRAWING TOLERANCES: CLIENT DETAILS

QUASAR CONSTRUCTIONSEASTERN CREEK SHOPPING CENTRE

179 ROOTY HILL RD SEASTERN CREEK NSW 2766

PROPOSED CAR PARK SHADE STRUCTURESSETOUT PLANSCALE

A3SHEET DRAWING NUMBER REV

3 OF 6 C

PROJECT NUMBER

S-677622.03.2019 ISSUED FOR REVIEW HTM FP

S-6776-DG-500-001.3

B 16.05.2019 RE-ISSUED FOR REVIEW FP

C 11.07.2019 RE-ISSUED FOR REVIEW FP

N

S

EW

400

400

750

750

SAILS TO BE FIXED TO RAFTERUSING TYPICAL SAIL CLEAT CONNECTION.

1:250

P1

NOTES: POST MARKINGS TO BE REFLECTED ON ENGINEERING AND WORKSHOP DRAWINGS FOR CONSISTENCY.

IN -LINE WITH KERB EDGE

SETOUT PLANSCALE: 1:250

IN -LINE WITH KERB EDGE

IN -LINE WITH KERB EDGE

IN-LINE WITH KERB EDGE

SAIL 1

SAIL 2

SAIL 4

SAIL 6

P2 P3 P4P5

SAIL 3

SAIL 5

P6 P7 P8 P9 P10 P11

P12 P13 P14 P15 P16 P17

P18 P19 P20 P21 P22 P23I HAVE REVIEWED THESE DRAWINGSAND CONFIRM THAT THE DESIGN IS INACCORDANCE WITH MYEXPECTATIONS AND IS CONSISTENTWITH THE SCOPE OF WORK AGREED.

SIGNED:

NAME:

DATE:

CLIENT APPROVAL

APPROVAL PENDINGNOT FOR CONSTRUCTION

GREENLINE GROUP PTY LTD3 Ball Place, WAGGA WAGGA NSW 2650P: 02 6938 1000 | E: [email protected]: 47 113 674 561

ALL DIMENSIONS IN mm U.N.O

0 DECIMAL PLACES ±1 ±1°

1 DECIMAL PLACE ±0.5 ±0.5°

DRAWING NUMBER REFERENCE DRAWING TITLE REV DATE REVISION DETAILS DRN CHK ENG APP

A

DRAWING TOLERANCES: CLIENT DETAILS

QUASAR CONSTRUCTIONSEASTERN CREEK SHOPPING CENTRE

179 ROOTY HILL RD SEASTERN CREEK NSW 2766

PROPOSED CAR PARK SHADE STRUCTURESSTRUCTURE PLANSCALE

A3SHEET DRAWING NUMBER REV

4 OF 6 C

PROJECT NUMBER

S-677622.03.2019 ISSUED FOR REVIEW HTM FP

S-6776-DG-500-001.4

B 16.05.2019 RE-ISSUED FOR REVIEW FP

C 11.07.2019 RE-ISSUED FOR REVIEW FP

N S

EW

CSHT-5

6200 4800 5200

7800

7800

7800

7800

31200

5200

7800

7800

7800

5200

33800

5200

7800

7800

7800

5200

33800

5200

7800

7800

7800

5200

33800

BSHT-5

ASHT-5

ASHT-5

15004800 4800

15004800

11100 11100

1:200

P1

NOTES: POST MARKINGS TO BE REFLECTED ON ENGINEERING AND WORKSHOP DRAWINGS FOR CONSISTENCY.

STRUCTURE PLANSCALE: 1:200

P2

P3

P4

P5

SAIL 1

SAIL 2 SAIL 4 SAIL 6

SIM

SAIL 3 SAIL 5

P6

P7

P8

P9

P10

P11

P12

P13

P14

P15

P16

P17

P18

P19

P20

P21

P22

P23

I HAVE REVIEWED THESE DRAWINGSAND CONFIRM THAT THE DESIGN IS INACCORDANCE WITH MYEXPECTATIONS AND IS CONSISTENTWITH THE SCOPE OF WORK AGREED.

SIGNED:

NAME:

DATE:

CLIENT APPROVAL

APPROVAL PENDINGNOT FOR CONSTRUCTION

GREENLINE GROUP PTY LTD3 Ball Place, WAGGA WAGGA NSW 2650P: 02 6938 1000 | E: [email protected]: 47 113 674 561

ALL DIMENSIONS IN mm U.N.O

0 DECIMAL PLACES ±1 ±1°

1 DECIMAL PLACE ±0.5 ±0.5°

DRAWING NUMBER REFERENCE DRAWING TITLE REV DATE REVISION DETAILS DRN CHK ENG APP

A

DRAWING TOLERANCES: CLIENT DETAILS

QUASAR CONSTRUCTIONSEASTERN CREEK SHOPPING CENTRE

179 ROOTY HILL RD SEASTERN CREEK NSW 2766

PROPOSED CAR PARK SHADE STRUCTURESELEVATIONSSCALE

A3SHEET DRAWING NUMBER REV

5 OF 6 C

PROJECT NUMBER

S-677622.03.2019 ISSUED FOR REVIEW HTM FP

S-6776-DG-500-001.5

B 16.05.2019 RE-ISSUED FOR REVIEW FP

C 11.07.2019 RE-ISSUED FOR REVIEW FP

ASHT-4

FFL

Label text

FFL

CSHT-4

4800 4800

11100

250022001800

250022001800

28003300

5200

4200

2800

1500

2800

GREENLINE WILL CARRY OUT A DBYD AND SERVICES SCAN, BUT HAVE NOT INCLUDED REPAIR/RELOCATION COSTS ASSOCIATED WITH UNDETECTED SERVICES.

BSHT-4

6200

18002200 2500

FFL

2400

750 750

STRUT

1SHT-6

AS NOTED

ELEVATIONSCALE: 1:75

COMMERCIAL 95 SHADEMESHCOLOUR:DESERT SAND

BORED PIER FOUNDATIONSALLOWANCE FOR 100KPA SOILS

NO ALLOWANCE FOR ROCK, SAND OR FILL STYLE PAD FOOTINGSSPOIL REMOVAL INCLUDED

ALLOWANCE FOR GPR SERVICES SCAN. NO ALLOWANCE FOR REPAIR OF UNDETECTED SERVICES.

CONCRETE FOUNDATIONS WILL BE STOPPED 200MM BELOW GROUND LEVEL. HOLES WILL BE TOPPED BY OTHERS AS PART OF SURFACING SCOPE.

HEAVY MACHINERY CAN DAMAGE SURFACESNO ALLOWANCE FOR REPAIR OF DAMAGED SURFACES

ELEVATIONSCALE: 1:75

CHS POST, RHS TOP FRAMESURFACE FINISH: HOT DIP GALVANISED

COMMERCIAL 95 SHADEMESHCOLOUR:DESERT SAND

COMMERCIAL 95 SHADEMESHCOLOUR:DESERT SAND

CHS POST, RHS TOP FRAMESURFACE FINISH: HOT DIP GALVANISED

ELEVATIONSCALE: 1:75

CHS POST, RHS TOP FRAMESURFACE FINISH: HOT DIP GALVANISED

I HAVE REVIEWED THESE DRAWINGSAND CONFIRM THAT THE DESIGN IS INACCORDANCE WITH MYEXPECTATIONS AND IS CONSISTENTWITH THE SCOPE OF WORK AGREED.

SIGNED:

NAME:

DATE:

CLIENT APPROVAL

APPROVAL PENDINGNOT FOR CONSTRUCTION

GREENLINE GROUP PTY LTD3 Ball Place, WAGGA WAGGA NSW 2650P: 02 6938 1000 | E: [email protected]: 47 113 674 561

ALL DIMENSIONS IN mm U.N.O

0 DECIMAL PLACES ±1 ±1°

1 DECIMAL PLACE ±0.5 ±0.5°

DRAWING NUMBER REFERENCE DRAWING TITLE REV DATE REVISION DETAILS DRN CHK ENG APP

A

DRAWING TOLERANCES: CLIENT DETAILS

QUASAR CONSTRUCTIONSEASTERN CREEK SHOPPING CENTRE

179 ROOTY HILL RD SEASTERN CREEK NSW 2766

PROPOSED CAR PARK SHADE STRUCTURESELECTRICAL ROUTING PROVISION PLANSCALE

A3SHEET DRAWING NUMBER REV

6 OF 6 C

PROJECT NUMBER

S-677622.03.2019 ISSUED FOR REVIEW HTM FP

S-6776-DG-500-001.6

B 16.05.2019 RE-ISSUED FOR REVIEW FP

C 11.07.2019 RE-ISSUED FOR REVIEW FP

N S

EW

1SHT-5

INSPECTION BOX DETAILSCALE: 1:25

125

500

ELECTRICAL ACCESS PANELON POSTS (P5, P11, P17, P23)

200

75

100MMØ HOLE IN BASE PLATE FOR ELECTRICAL ROUTING,MAY CHANGE DEPENDING ON ENGINEERS SPECIFICATION.

ELECTRICAL ROUTING PROVISION PLANSCALE: 1:250

ELECTRICAL ROUTING THROUGH STRUCTURESPROVIDE 32Ø HOLES IN MEMBERS AND PLATES FOR ROUTING

1:250

P1

P2

P3

P4

P5

SAIL 1

IP IP IP IP

NOTES: POST MARKINGS TO BE REFLECTED ON ENGINEERING AND WORKSHOP DRAWINGS FOR CONSISTENCY.

PROVISION FOR LIGHTING (PENETRATIONS ONLY) LIGHTING SCOPE TO BE COMPLETED BY OTHERS.

LEGEND:

ELECTRICAL ROUTING

INSPECTION POINTIP

SAIL 2 SAIL 4 SAIL 6SAIL 3 SAIL 5

P6

P7

P8

P9

P10

P11

P12

P13

P14

P15

P16

P17

P18

P19

P20

P21

P22

P23

POWERFEED

POWERFEED

POWERFEED POWER

FEED

I HAVE REVIEWED THESE DRAWINGSAND CONFIRM THAT THE DESIGN IS INACCORDANCE WITH MYEXPECTATIONS AND IS CONSISTENTWITH THE SCOPE OF WORK AGREED.

SIGNED:

NAME:

DATE:

CLIENT APPROVAL

APPROVAL PENDINGNOT FOR CONSTRUCTION