Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b...

17
A1 P1 P1 OR A1 OH 1 2 1 P2 B P2 GENERAL FLOOR PLAN NOTES RISER OR STACK NUMBER DETAIL: B = DETAIL DESIGNATION P2 = SHEET WHERE DETAIL IS LOCATED FIRE SUPPRESSION HAZARD CLASSIFICATION AND HAZARD CLASSIFICATION GROUP SECTION: 1 = SECTION DESIGNATION P2 = SHEET WHERE DETAIL IS LOCATED EQUIPMENT REFERENCE. LETTER DESIGNATION VARIES. REFER TO SCHEDULES. EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK. LETTER DESIGNATIONS REFER TO SCHEDULES. CONNECT TO EXISTING PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN UNLESS NOTED OTHERWISE. DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL. "UP TO" SYMBOL (ITEM ON FLOOR ABOVE) 10" 10" ELEV: 8' - 0" ELEV: 8' - 0" TOE: 3' - 0" BOE: 0' - 6" APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP OR BOTTOM OF EQUIPMENT, UNLESS NOTED OTHERWISE APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO CENTERLINE OF PIPE, UNLESS NOTED OTHERWISE FIRE SUPPRESSION SYMBOLS DOUBLE LINE SINGLE LINE CONCEALED PENDENT SPRINKLER FS PIV S FIRE HYDRANT FLOW SWITCH GATE VALVE OS&Y INSTITUTIONAL PENDENT SPRINKLER PENDENT SPRINKLER POST INDICATOR VALVE RECESSED PENDENT SPRINKLER SIDE WALL SPRINKLER SUPERVISED VALVE UPRIGHT SPRINKLER PIPING SYMBOLS DOUBLE LINE SINGLE LINE BOTTOM CONNECTION (45°) BRANCH TEE CONNECTION (NOTE: BULLHEAD TEE'S ARE NOT PERMITTED) DIRECTION OF PITCH DROP ELBOW DOWN ELBOW UP EXISTING PIPE TO BE REMOVED EXISTING PIPE TO REMAIN FLOW DIRECTION DESIGNATION PUMP RISE TOP CONNECTION (45°) TOP CONNECTION (90°) BOTTOM CONNECTION (90°) D D R R SPECIALTY GAS SYMBOLS AIR OUTLET - LAB TYPE VC VC CARBON DIOXIDE OUTLET - HOSPITAL TYPE MEDICAL AIR OUTLET - HOSPITAL TYPE MEDICAL VACUUM INLET - HOSPITAL TYPE NITROGEN OUTLET - HOSPITAL TYPE NITROUS OXIDE OUTLET - HOSPITAL TYPE OXYGEN OUTLET - HOSPITAL TYPE WAGD INLET - HOSPITAL TYPE NATURAL GAS OUTLET - LAB TYPE VACUUM OUTLET - LAB TYPE VACUUM CLEANING STATION - WALL VACUUM CLEANING STATION - FLOOR PLUMBING AND FIRE SUPPRESSION PIPING DESIGNATIONS DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC HOT WATER RETURN EXISTING PIPE TO REMAIN EXISTING PIPE TO BE REMOVED HOT WATER PIPE (140 DEGS. F.) HOT WATER PIPE (180 DEGS. F.) HOT WATER RETURN PIPE (140 DEGS. F.) HOT WATER RETURN PIPE (180 DEGS. F.) ARGON PIPE COMPRESSED AIR PIPE MEDICAL CARBON DIOXIDE PIPE COMBINATION FIRE SUPPRESSION AND DOMESTIC WATER SERVICE DIESEL FUEL PIPE SPRINKLER PIPE (DRY) FIRE SUPPRESSION (STANDPIPE / SPRINKLER MAIN) FIRE SERVICE FUEL OIL FLOW LINE FUEL OIL GAUGE LINE FUEL OIL RETURN LINE FUEL OIL SUPPLY LINE NATURAL GAS PIPE GARAGE DRAINAGE PIPE GAS SERVICE HYDROGEN PIPE HELIUM PIPE MEDICAL INSTRUMENT AIR PIPE KITCHEN WASTE PIPE LABORATORY COMPRESSED AIR PIPE LABORATORY VENT PIPE LABORATORY VACUUM PIPE LABORATORY WASTE PIPE MEDICAL NITROGEN PIPE MEDICAL COMPRESSED AIR PIPE MEDICAL-SURGICAL VACUUM PIPE GASOLINE PIPE (NON-LEAD) MEDICAL NITROUS OXIDE PIPE NON-POTABLE MEDICAL OXYGEN PIPE (OVERFLOW) SECONDARY STORM DRAINAGE PIPE PROPANE GAS PIPE PUMP DISCHARGE PIPE PRE-ACTION / DELUGE SPRINKLER PIPE PURE WATER PIPE SPRINKLER PIPE (WET) SANITARY DRAINAGE PIPE SOFT COLD WATER SPRINKLER DRAIN PIPE STORM DRAINAGE PIPE FUEL TANK VENT PIPE TRAP PRIMER DISCHARGE PIPE TEMPERED WATER PIPE SANITARY SEWER VENT WASTE ANESTHESIA GAS DISPOSAL PIPE WATER SERVICE 140 LV 180 140R 180R AR CA CO2 CWS DF DS F FS FOF FOG FOR FOS G GD GS H2 HE IA IV IW LA LV LW N2 MA MV NG NO NPW O2 OD P PD PS PW S SAN SCW SD STM T TP TW V WAGD WS INDIRECT VENT PIPE INDIRECT WASTE PIPE K 3 3 CHECK VALVE T P FOB FOT SHUTOFF VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON APPLICATIONS) CONCENTRIC PIPE REDUCER ECCENTRIC PIPE REDUCER PRESSURE GAUGE TEMPERATURE GAUGE OR THERMOMETER UNION CLEANOUT STRAINER STRAINER WITH A BLOW DOWN VALVE AND HOSE CONNECTION DRAIN VALVE WITH HOSE END CONNECTION AUTOMATIC FLOW CONTROLLER WITH P/T PLUG IN AND OUT EXPANSION JOINT PRESSURE REGULATING VALVE SAFETY RELIEF VALVE. PIPE DISCHARGE AIR GAPPED TO FLOOR DRAIN UNLESS NOTED OTHERWISE. PRESSURE AND TEMPERATURE TEST PLUG TRAP PRIMER VACUUM GAUGE WITH STOP CLEANOUT TO GRADE OR FINISHED FLOOR END CAP MIXING FAUCET PLUG HOSE BIB WALL HYDRANT PLUG VALVE SHUTOFF VALVE AND BOX SHUTOFF VALVE ON RISER V VB TP CO COMBINATION SHUTOFF AND BALANCING VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON APPLICATIONS) BALL VALVE BUTTERFLY VALVE GATE VALVE VALVES AND FITTINGS DOUBLE LINE SINGLE LINE SOLENOID VALVE S P/T PRESSURE AND TEMPERATURE SAFETY RELIEF VALVE. PIPE DISCHARGE AIR GAPPED TO FLOOR DRAIN UNLESS NOTED OTHERWISE. FIRE DEPARTMENT VALVE WATER METER M ACID VENT PIPE AV ACID WASTE PIPE AW ABBREVIATIONS AAP - AREA ALARM PANEL (MEDICAL GAS) AC - AIR COMPRESSOR OR AIR CONDITIONER ACC - ACCESS ACCU - AIR COOLED CONDENSING UNIT AD - ACCESS DOOR OR AREA DRAIN ADB - ACID DILUTION BASIN ADJ - ADJUSTABLE AFF - ABOVE FINISHED FLOOR AFG - ABOVE FINISHED GRADE ALT - ALTERNATE AP - ACCESS PANEL APPROX - APPROXIMATE AR - AIR RECEIVER OR ARGON ARCH - ARCHITECT OR ARCHITECTURAL ASSY - ASSEMBLY AV - ACID VENT AW - ACID WASTE BDD - BACK DRAFT DAMPER BFP - BACKFLOW PREVENTER BLDG - BUILDING BOB - BOTTOM OF BEAM BOD - BOTTOM OF DUCT BOE - BOTTOM OF EQUIPMENT BOF - BOTTOM OF FOOTING BOG - BOTTOM OF GRILLE BOP - BOTTOM OF PIPE BOT - BOTTOM BT - BATHTUB BTU - BRITISH THERMAL UNIT BTUH - BRITISH THERMAL UNIT PER HOUR BTWN - BETWEEN CA - COMPRESSED AIR CB - CATCH BASIN CBD - COUNTER BALANCED BACKDRAFT DAMPER CFCI - CONTRACTOR FURNISHED CONTRACTOR INSTALLED CFM - CUBIC FEET PER MINUTE CHS - CHILLED WATER SUPPLY CHR - CHILLED WATER RETURN CI - CAST IRON CK - CLINICAL SINK CLG - CEILING CMU - CONCRETE MASONRY UNIT CO - CLEAN OUT CO2 - MEDICAL CARBON DIOXIDE CONN - CONNECT OR CONNECTION CONTR - CONTRACTOR CORR - CORRIDOR CS - CLINICAL SINK OR COLD SOFT WATER CTR - CENTER CU - COPPER CW - COLD WATER CWS - COMBINATION WATER SERVICE OR CONDENSER WATER SUPPLY CWR - CONDENSER WATER RETURN D - DEPTH OR DRAIN LINE DD - DECK DRAIN DET - DETAIL DF - DRINKING FOUNTAIN OR WATER COOLER OR DIESEL FUEL DFU - DRAINAGE FIXTURE UNIT DI - DEIONIZED WATER DIA - DIAMETER DIM - DIMENSION DN -DOWN DS - DOWN SPOUT OR SPRINKLER (DRY) DT - PERFORATED DRAIN TILE DWG - DRAWING EA - EACH EC - ELECTRICAL CONTRACTOR (DIVISION 26) EEW - EMERGENCY EYE WASH EJ - EXPANSION JOINT ELEC - ELECTRICAL ELEV - ELEVATOR EQ - EQUAL EQUIP - EQUIPMENT ET - EXPANSION TANK ETR - EXISTING TO REMAIN ES - EMERGENCY SHOWER EQS - EQUIPMENT SUPPLIER EWC - ELECTRICAL WATER COOLER EXH - EXHAUST AIR EXP - EXPANSION EXT - EXTERIOR EX - EXISTING F - FIRE SUPPRESSION (STANDPIPE/SPRINKLER MAIN) FCE - FIRE CONTROL EQUIPMENT FCO - FLOOR CLEANOUT FD - FLOOR DRAIN FDC - FIRE DEPARTMENT CONNECTION FDV - FIRE DEPARTMENT VALVE FF - FINISHED FLOOR ELEVATION FHC - FIRE HOSE CABINET FLR - FLOOR FM - FORCE MAIN FOB - FLAT ON BOTTOM FOF - FUEL OIL FLOW FOG - FUEL OIL GAUGE FOR - FUEL OIL RETURN FOS - FUEL OIL SUPPLY FOT - FLAT ON TOP FPM - FEET PER MINUTE FR - FIRE RISER FS - FLOOR SINK OR FIRE SERVICE FSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21) FT - FEET FTG - FOOTING G - GAS OR NATURAL GAS GA - GAUGE GAL - GALLON GALV - GALVANIZED GC - GENERAL TRADES CONTRACTOR GD - GARAGE DRAINAGE GPM - GALLONS PER MINUTE GS - GAS SERVICE GW - GREASE WASTE H2 - HYDROGEN HB - HOSE BIBB HC - HVAC CONTRACTOR (DIVISION 23) HD - HUB DRAIN HE - HELIUM HG - REFRIGERANT HOT GAS HP - HORSEPOWER OR HIGH POINT HPC - HIGH PRESSURE CONDENSATE RETURN HPS - HIGH PRESSURE STEAM SUPPLY HPW - HIGH PURITY WATER HPWR - HIGH PURITY WATER RETURN HR - HOSE REEL HT - HEAT TRACE HTR - HEATER HVAC - HEATING, VENTILATING, AND AIR CONDITIONING HW - HOT WATER HWR - HEATING HOT WATER RETURN HWS - HEATING HOT WATER SUPPLY IA - MEDICAL INSTRUMENT AIR ID - INSIDE DIAMETER INV - INVERT ELEVATION IN - INCHES IV - INDIRECT VENT IW - INDIRECT WASTE JS - JANITOR SINK K - KITCHEN WASTE KEC - KITCHEN EQUIPMENT CONTRACTOR L - LENGTH LA - LABORATORY COMPRESSED AIR LAV - LAVATORY LBS - POUNDS LCW - LABORATORY COLD WATER LEC - LABORATORY EQUIPMENT CONTRACTOR LHW - LABORATORY HOT WATER LHWR - LABORATORY HOT WATER RETURN LPC - LOW PRESSURE CONDENSATE RETURN LPS - LOW PRESSURE STEAM SUPPLY LV - LABORATORY VACUUM OR LABORATORY VENT LW - LABORATORY WASTE MA - MEDICAL COMPRESSED AIR MAP - MASTER ALARM PANEL (MEDICAL GAS) MAX - MAXIMUM MB - MOP BASIN MC - MECHANICAL CONTRACTOR (DIVISION 23) MEZZ - MEZZANINE MFR - MANUFACTURER MH - MANHOLE MIN - MINIMUM OR MINUTE MISC - MISCELLANEOUS MTD - MOUNTED MTG - MOUNTING MPC - MEDIUM PRESSURE CONDENSATE RETURN MPS - MEDIUM PRESSURE STEAM SUPPLY MU - WATER MAKE-UP MV - MEDICAL SURGICAL VACUUM N2 - MEDICAL NITROGEN N/C - NORMALLY CLOSED NG - GASOLINE (NON-LEAD) NIC - NOT IN CONTRACT N/O - NORMALLY OPEN NO - MEDICAL NITROUS OXIDE NOM - NOMINAL NPW - NON-POTABLE WATER NPT - NATIONAL PIPE THREAD NTS - NOT TO SCALE 02 - MEDICAL OXYGEN OA - OUTDOOR AIR OD - OUTSIDE DIAMETER OR OVERFLOW DRAIN OFCI - OWNER FURNISHED CONTRACTOR INSTALLED OFOI - OWNER FURNISHED OWNER INSTALLED P - PROPANE GAS PC - PLUMBING CONTRACTOR (DIVISION 22) OR PUMPED CONDENSATE RETURN PD - PUMP DISCHARGE OR PARAPET DRAIN PIV - POST INDICATOR VALVE PLBG - PLUMBING PS - PRE-ACTION/DELUGE SPRINKLER PRESS - PRESSURE PRV - PRESSURE REGULATING VALVE PSF - POUNDS PER SQUARE FOOT PSI - POUNDS PER SQUARE INCH PSV - PRESSURE SUSTAINING VALVE PSIG - POUNDS PER SQUARE INCH GAUGE PW - PURE WATER RA - RETURN AIR RAD - RADIUS RCP - REINFORCED CONCRETE PIPE RD - ROOF DRAIN REC - RECESSED REQD - REQUIRED RI - ROUGH IN RL - REFRIGERANT LIQUID ROS - REVERSE OSMOSIS WATER SUPPLY ROR - REVERSE OSMOSIS WATER RETURN RPM - REVOLUTIONS PER MINUTE RS - REFRIGERANT SUCTION RV - RELIEF VALVE S - SPRINKLER (WET) SA - SHOCK ARRESTOR OR SUPPLY AIR SAN - SANITARY OR SANITARY DRAIN SCH - SCHEDULE SCW - SOFT COLD WATER SD - SPRINKLER DRAIN OR SUBSOIL DRAIN SH - SHOWER SHT - SHEET SK - SINK SPEC - SPECIFICATIONS SQ - SQUARE SR - SUPPLY RISER SS - SANITARY STACK (SOIL OR WASTE) OR STAINLESS STEEL STD - STANDARD STM - STORM OR STORM DRAINAGE STRUC - STRUCTURAL OR STRUCTURE SUC - SITE UTILITY CONTRACTOR T - FUEL TANK VENT TD - TRENCH DRAIN TEMP - TEMPERATURE TOB - TOP OF BEAM TOD - TOP OF DUCT TOE - TOP OF EQUIPMENT TOF - TOP OF FOOTING TOJ - TOP OF JOIST TOP - TOP OF PIPE TOS - TOP OF SLAB OR TOP OF STEEL TF - TRAP FILLER TP - TRAP PRIMER OR TRAP PRIMER DISCHARGE TW - TEMPERED WATER TYP - TYPICAL UR - URINAL UNO - UNLESS NOTED OTHERWISE V - VENT OR SANITARY SEWER VENT VAC - VACUUM VC - VACUUM CLEANING VCV - VACUUM CLEANING VALVE VE - VACUUM EXHAUST VEL - VELOCITY VIB - VALVE IN BOX VOL - VOLUME VP - VACUUM PUMP VS - VENT STACK VTR - VENT THROUGH ROOF VR - VENT RISER W/ - W ITH W/0 - WITHOUT W - WASTE WAGD - WASTE ANESTHESIA GAS DISPOSAL WC - WATER CLOSET WCO - WALL CLEANOUT WH - WALL HYDRANT OR WATER HEATER W IV - WALL INDICATOR VALVE WS - WATER SERVICE YCO - YARD CLEANOUT ZVC - ZONE VALVE CABINET PIPE RISER NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT TO MODIFICATIONS ON OTHER DRAWINGS. ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT NECESSARILY BE USED ON THIS PROJECT. GENERAL NOTES A ALL PIPING IS ABOVE THE CEILING (AT THE UNDERSIDE OF STRUCTURE IN EXPOSED STRUCTURE AREAS), UNLESS OTHERWISE NOTED. B REFER TO SCHEDULES, DETAILS AND DIAGRAMS FOR PIPING, PIPE SIZES AND PIPELINE DEVICES NOT INDICATED ON THE FLOOR PLAN. C ABOVE CEILING UTILITY SPACE IS LIMITED. COORDINATION WITH ALL TRADES IS CRITICAL, PRIOR TO INSTALLATION ON ANY WORK. D LOCATIONS AND SIZES OF EXISTING PIPING HAVE BEEN DETERMINED FROM A REVIEW OF EXISTING DRAWINGS AND/OR SITE INSPECTION, WHERE POSSIBLE. FIELD VERIFICATION OF EXACT LOCATIONS, ELEVATIONS, INVERTS, SIZES, DIRECTION OF FLOW, ETC. SHALL BE REQUIRED PRIOR TO BEGINNING NEW WORK. E ALL PIPING SHALL BE REMOVED BACK TO ACTIVE MAINS AND CAPPED, OR REMOVED BACK TO POINTS OF CONNECTION IN NEW WORK. DOMESTIC WATER PIPING SHALL BE REMOVED BACK TO WITHIN 2 PIPE DIAMETERS OF ACTIVE BRANCH/MAIN. NO DEADLEGS SHALL REMAIN. INACCESSIBLE PIPING, WHERE SO NOTED, TO BE ABANDONED SHALL BE DISCONNECTED FROM ACTIVE SYSTEMS AND CAPPED OR PLUGGED IN CONCEALED LOCATIONS. ALL ABANDONED PIPING SHALL BE CAPPED AT INLET AND OUTLET. F NEW CONNECTIONS TO EXISTING PIPING SHALL BE WITH THE SAME SIZE AS THE EXISTING PIPING, UNLESS OTHERWISE NOTED. G ALL REMOVED MATERIAL AND EQUIPMENT, SO DESIGNATED BY THE OWNER, SHALL BE TURNED OVER AND PLACED WHERE DIRECTED. ALL MATERIAL AND EQUIPMENT, WHICH THE OWNER DOES NOT WISH TO RETAIN, SHALL BECOME THE PROPERTY OF THE CONTRACTOR RESPONSIBLE FOR THE REMOVAL. H REFER TO THE ARCHITECTURAL PLANS FOR PROJECT PHASING REQUIREMENTS. I ANNULAR SPACE OF PIPE, CONDUIT AND OTHER SIMILAR PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE FIRESTOPPED. IN ADDITION, PENETRATIONS THRU RATED FLOORS SHALL ALSO BE FIRESTOPPED TO RETARD PASSAGE OF FIRE AND SMOKE. REFER TO SPECIFICATIONS. REFER TO ARCHITECTURAL DRAWING(S) FOR CONSTRUCTION, LAYOUT AND FIRE RATINGS OF FLOORS, WALLS, PARTITIONS AND OTHER BUILDING ELEMENTS. REFER TO ARCHITECTURAL DRAWINGS FOR PENETRATION DETAILS. J MEDICAL GAS SUPPLY PIPING SHALL BE MINIMUM 0.5” SIZE. MEDICAL VACUUM AND WASTE ANETHESIA GAS DISPOSAL PIPING SHALL BE MINIMUM 0.75" SIZE. K ALL MEDICAL GAS SYSTEM INSTALLERS SHALL BE CERTIFIED TO THE REQUIREMENTS OF ASSE 6010. ALL MEDICAL GAS SYSTEM VERIFIERS SHALL BE CERTIFIED TO THE REQUIREMENTS OF ASSE 6030. L MEDICAL GAS AND VACUUM SYSTEM INSTALLATION AND VERIFICATION SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 99, GAS AND VACUUM SYSTEMS, 2012 EDITION. FIRE SUPPRESSION DESIGN NOTES A REFER TO ARCHITECTURAL DRAWINGS FOR LIMITS OF CONSTRUCTION. COORDINATE SPRINKLER LOCATIONS WITH CEILING DEVICES (LIGHTING, GRILLES, ETC.) REFER TO PLUMBING DRAWINGS, PLAN NOTES AND GENERAL NOTES FOR ALL WORK ASSOCIATED WITH THE FIRE SUPPRESSION CONTRACT. B FIRE SUPPRESSION SPRINKLER SYSTEMS. REFER TO DRAWINGS AND SPECIFICATIONS FOR COMPLETE SCOPE OF WORK. 1 RENOVATION AREA(S) TO BE TOTALLY SPRINKLERED. EXISTING SPRINKLER SYSTEMS TO BE MODIFIED AND/OR EXTENDED TO CONFORM TO THE NEW LAYOUT. NEW SPRINKLERS ARE TO BE INTEGRATED INTO THE EXISTING SPRINKLER SYSTEM. PROVIDE NEW SPRINKLER ZONE CONTROL VALVE IF NECESSARY. ALL EXISTING SPRINKLERS, REMOVED OR DISTURBED IN RENOVATION AREAS, SHALL BE DISPOSED OF AND REPLACED WITH NEW SPRINKLERS, AS INDICATED ON THE DRAWINGS. C BASIS FOR DESIGN OF FIRE SUPPRESSION SYSTEMS TO BE LIGHT HAZARD OCCUPANCY, EXCEPT MECHANICAL ROOMS, STORAGE ROOMS, AND OTHER AREAS REQUIRED BY CODE WHICH ARE ORDINARY GROUP 1; 1 LIGHT HAZARD: 1500 SQUARE FEET MIN. AREA OF OPERATION, 0.10 GPM/SQ.FT. DENSITY, 225 SQUARE FEET MAXIMUM PER SPRINKLER. A 100 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE SHALL BE USED IN THE DESIGN. 2 ORDINARY HAZARD (GROUP 1): 1500 SQUARE FEET MIN. AREA OF OPERATION, 0.15 GPM/SQ.FT. DENSITY, 130 SQ. FT. MAX. PER SPRINKLER. A 250 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE SHALL BE USED IN THE DESIGN. 3 AREA OF OPERATION REDUCTIONS AND INCREASES SHALL BE CALCULATED PER NFPA STANDARDS. VERIFY DENSITIES WITH GOVERNING AUTHORITIES AND OWNER’S INSURER BEFORE PROCEEDING WITH DESIGN OF SYSTEM(S). IF GOVERNING AUTHORITIES OR OWNER’S INSURER REQUIREMENTS ARE MORE STRINGENT THOSE REQUIREMENTS SHALL PREVAIL. D SPRINKLERS SHALL BE LOCATED IN THE CENTER OF SQUARE PADS AND AT THE CENTER OR AT QUARTERPOINTS OF THE LONG AXIS OF RECTANGULAR PADS. 1 SPRINKLERS IN AREAS WITHOUT CEILINGS SHALL BE QUICK RESPONSE BRASS UPRIGHT OR QUICK RESPONSE PENDENT TYPE. 2 SPRINKLERS IN AREAS WITH CEILINGS SHALL BE QUICK RESPONSE TWO-PIECE ADJUSTABLE CONCEALED PENDENT TYPE WITH WHITE COVERPLATE. E EXERCISE SPECIAL CARE TO COORDINATE PIPING AND EQUIPMENT LOCATIONS WITH ALL OTHER TRADES. F ALL NEW WORK SHALL BE COMPLIANT WITH RULES AND REGULATIONS OF NFPA-13 OR THE GOVERNING AUTHORITY IF MORE STRINGENT. Kettering Health Network Grandview Medical Center KEY PLAN: REVISIONS: NOTES: Date Checked By Drawn By Job No. Sheet No. No. Date Description 405 W. GRAND AVE. DAYTON, OHIO 45405 CATH LAB#4 RENOVATION 3rd Floor www.pinnaclearchitects.com PHONE: 937. 222. 1117 FAX: 937. 222. 4893 MIAMISBURG, OH 45342 480 VANTAGE POINT, SUITE 201 1400 W Dorothy Lane, Dayton, OH 45409 P: 937 - 224 - 0861 www.heapy.com LARRY L. O H A T S T E O F I O COTTERMAN E-60417 I E F O R P A S S N O I G N E L S I G E R D E R E T E N R E PROJECT NO. OHIO COA FIRM NO. 01528 2018-05059.01 12" = 1'-0" 2019.05.24 E.P001 PLUMBING LEGEND, GENERAL NOTES AND SHEET INDEX 05/24/19 WSM DPB PHE - SHEET LIST - PLUMBING Sheet Number Sheet Name E.P001 PLUMBING LEGEND, GENERAL NOTES AND SHEET INDEX E.P002 PLUMBING SCHEDULES & DIAGRAM E.P102 PARTIAL FIRST AND SECOND FLOOR PLANS E.P103 PARTIAL THIRD FLOOR PLANS 1 2019.05.24 PERMIT SET

Transcript of Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b...

Page 1: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

A1

P1 P1OR

A1

OH1

2

1

P2

B

P2

GENERAL FLOOR PLAN NOTES

RISER OR STACK NUMBER

DETAIL: B = DETAIL DESIGNATION P2 = SHEET W HERE DETAIL IS LOCATED

FIRE SUPPRESSION HAZARD CLASSIFICATION AND HAZARD CLASSIFICATION GROUP

SECTION: 1 = SECTION DESIGNATION P2 = SHEET W HERE DETAIL IS LOCATED

EQUIPMENT REFERENCE. LETTER DESIGNATION VARIES. REFER TO SCHEDULES.

EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK. LETTER DESIGNATIONS REFER TO SCHEDULES.

CONNECT TO EXISTING

PLAN NOTE. APPLIES ONLY TO THE SHEET W HICH IT IS SHOW N UNLESS NOTED OTHERW ISE.

DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.

"UP TO" SYMBOL (ITEM ON FLOOR ABOVE)

10" 10"

ELEV: 8' - 0"ELEV: 8' - 0"

TOE: 3' - 0"

BOE: 0' - 6"

APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP OR BOTTOM OF EQUIPMENT, UNLESS NOTED OTHERW ISE

APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO CENTERLINE OF PIPE, UNLESS NOTED OTHERW ISE

FIRE SUPPRESSION SYMBOLSDOUBLE LINE SINGLE LINE

CONCEALED PENDENT SPRINKLER

FS

PIV

S

FIRE HYDRANT

FLOW SW ITCH

GATE VALVE OS&Y

INSTITUTIONAL PENDENT SPRINKLER

PENDENT SPRINKLER

POST INDICATOR VALVE

RECESSED PENDENT SPRINKLER

SIDE W ALL SPRINKLER

SUPERVISED VALVE

UPRIGHT SPRINKLER

PIPING SYMBOLSDOUBLE LINE SINGLE LINE

BOTTOM CONNECTION (45°)

BRANCH TEE CONNECTION (NOTE: BULLHEAD TEE'S ARE NOT PERMITTED)

DIRECTION OF PITCH

DROP

ELBOW DOW N

ELBOW UP

EXISTING PIPE TO BE REMOVED

EXISTING PIPE TO REMAIN

FLOW DIRECTION DESIGNATION

PUMP

RISE

TOP CONNECTION (45°)

TOP CONNECTION (90°)

BOTTOM CONNECTION (90°)

DD

RR

SPECIALTY GAS SYMBOLS

AIR OUTLET - LAB TYPE

VC

VC

CARBON DIOXIDE OUTLET - HOSPITAL TYPE

MEDICAL AIR OUTLET - HOSPITAL TYPE

MEDICAL VACUUM INLET - HOSPITAL TYPE

NITROGEN OUTLET - HOSPITAL TYPE

NITROUS OXIDE OUTLET - HOSPITAL TYPE

OXYGEN OUTLET - HOSPITAL TYPE

W AGD INLET - HOSPITAL TYPE

NATURAL GAS OUTLET - LAB TYPE

VACUUM OUTLET - LAB TYPE

VACUUM CLEANING STATION - W ALL

VACUUM CLEANING STATION - FLOOR

PLUMBING AND FIRE SUPPRESSION

PIPING DESIGNATIONS

DOMESTIC COLD W ATER

DOMESTIC HOT W ATER

DOMESTIC HOT W ATER RETURN

EXISTING PIPE TO REMAIN

EXISTING PIPE TO BE REMOVED

HOT W ATER PIPE (140 DEGS. F.)

HOT W ATER PIPE (180 DEGS. F.)

HOT W ATER RETURN PIPE (140 DEGS. F.)

HOT W ATER RETURN PIPE (180 DEGS. F.)

ARGO N PIPE

COMPRESSED AIR PIPE

MEDICAL CARBON DIOXIDE PIPE

COMBINATION FIRE SUPPRESSION AND DOMESTIC W ATER SERVICE

DIESEL FUEL PIPE

SPRINKLER PIPE (DRY)

FIRE SUPPRESSION (STANDPIPE / SPRINKLER MAIN)

FIRE SERVICE

FUEL OIL FLOW LINE

FUEL OIL GAUGE LINE

FUEL OIL RETURN LINE

FUEL OIL SUPPLY LINE

NATURAL GAS PIPE

GARAGE DRAINAGE PIPE

GAS SERVICE

HYDROGEN PIPE

HELIUM PIPE

MEDICAL INSTRUMENT AIR PIPE

KITCHEN W ASTE PIPE

LABORATORY COMPRESSED AIR PIPE

LABORATORY VENT PIPE

LABORATORY VACUUM PIPE

LABORATORY W ASTE PIPE

MEDICAL NITROGEN PIPE

MEDICAL COMPRESSED AIR PIPE

MEDICAL-SURGICAL VACUUM PIPE

GASOLINE PIPE (NON-LEAD)

MEDICAL NITROUS OXIDE PIPE

NON-POTABLE

MEDICAL OXYGEN PIPE

(OVERFLOW ) SECONDARY STORM DRAINAGE PIPE

PROPANE GAS PIPE

PUMP DISCHARGE PIPE

PRE-ACTION / DELUGE SPRINKLER PIPE

PURE W ATER PIPE

SPRINKLER PIPE (W ET)

SANITARY DRAINAGE PIPE

SOFT COLD W ATER

SPRINKLER DRAIN PIPE

STORM DRAINAGE PIPE

FUEL TANK VENT PIPE

TRAP PRIMER DISCHARG E PIPE

TEMPERED W ATER PIPE

SANITARY SEW ER VENT

W ASTE ANESTHESIA GAS DISPOSAL PIPE

W ATER SERVICE

140

LV

180

140R

180R

AR

CA

CO2

CW S

DF

DS

F

FS

FOF

FOG

FOR

FOS

G

GD

GS

H2

HE

IA

IV

IW

LA

LV

LW

N2

MA

MV

NG

NO

NPW

O2

OD

P

PD

PS

PW

S

SAN

SCW

SD

STM

T

TP

TW

V

W AGD

W S

INDIR ECT VEN T PIPE

INDIRECT W ASTE PIPE

K

3

3

CHECK VALVE

T

P

FOB

FOT

SHUTOFF VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON APPLICATIONS)

CONCENTRIC P IPE REDUCER

ECC ENTRIC PIPE REDUCER

PRESSURE GAUGE

TEMPERATURE GAUGE OR THERM OMETER

UNION

CLEANOUT

STRAINER

STRAINER W ITH A BLOW DOW N VALVE AND HOSE CONNECTION

DRAIN VALVE W ITH HOSE END CONNECTION

AUTOMATIC FLOW CONTROLLER W ITH P/T PLUG IN AND OUT

EXPANSION JOINT

PRESSURE REGULATING VALVE

SAFETY RELIEF VALVE. PIPE DISCHARGE AIR GAPPED TO FLOOR DRAIN UNLESS NOTED OTHERW ISE.

PRESSURE AND TEMPERATURE TEST PLUG

TRAP PRIMER

VACUUM GAUGE W ITH STOP

CLEANOUT TO GRADE OR FINISHED FLOOR

END CAP

MIXING FAUCET

PLUG

HOSE BIB

W ALL HYDRANT

PLUG VALVE

SHUTOFF VALVE AND BOX

SHUTOFF VALVE ON RISER

V

VB

TP

CO

COMBINATION SHUTOFF AND BALANCING VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON APPLICATIONS)

BALL VALVE

BUTTERFLY VALVE

GATE VALVE

VALVES AND FITTINGSDOUBLE LINE SINGLE LINE

SOLENOID VALVES

P/T PRESSURE AND TEMPERATURE SAFETY RELIEF VALVE. PIPE DISCHARGE AIR GAPPED TO FLOOR DRAIN UNLESS NOTED OTHERW ISE.

FIRE DEPARTMENT VALVE

W ATER METERM

ACID VENT PIPEAV

ACID W ASTE PIPEAW

ABBREVIATIONS

AAP - AREA ALARM PANEL (MEDICAL GAS)AC - AIR COMPRESSOR OR AIR CONDITIONERACC - ACCESSACCU - AIR COOLED CONDENSING UNITAD - ACCESS DOOR OR AREA DRAINADB - ACID DILUTION BASINADJ - ADJUSTABLEAFF - ABOVE FINISHED FLOORAFG - ABOVE FINISHED GRADEALT - ALTERNATEAP - ACCESS PANELAPPROX - APPROXIMATEAR - AIR RECEIVER OR ARGONARCH - ARCHITECT OR ARCHITECTURALASSY - ASSEMBLYAV - ACID VENTAW - ACID W ASTE

BDD - BACK DRAFT DAMPERBFP - BACKFLOW PREVENTERBLDG - BUILDINGBOB - BOTTOM OF BEAMBOD - BOTTOM OF DUCTBOE - BOTTOM OF EQUIPMENTBOF - BOTTOM OF FOOTINGBOG - BOTTOM OF GRILLEBOP - BOTTOM OF PIPEBOT - BOTTOMBT - BATHTUBBTU - BRITISH THERMAL UNITBTUH - BRITISH THERMAL UNIT PER HOURBTW N - BETW EEN

CA - COMPRESSED AIRCB - CATCH BASINCBD - COUNTER BALANCED BACKDRAFT DAMPERCFCI - CONTRACTOR FURNISHED CONTRACTOR

INSTALLEDCFM - CUBIC FEET PER MINUTECHS - CHILLED W ATER SUPPLYCHR - CHILLED W ATER RETURNCI - CAST IRONCK - CLINICAL SINKCLG - CEILINGCMU - CONCRETE MASONRY UNITCO - CLEAN OUTCO2 - MEDICAL CARBON DIOXIDECONN - CONNECT OR CONNECTIONCONTR - CONTRACTORCORR - CORRIDORCS - CLINICAL SINK OR COLD SOFT W ATERCTR - CENTERCU - COPPERCW - COLD W ATERCW S - COMBINATION W ATER SERVICE

OR CONDENSER W ATER SUPPLYCW R - CONDENSER W ATER RETURN

D - DEPTH OR DRAIN LINEDD - DECK DRAINDET - DETAILDF - DRINKING FOUNTAIN OR W ATER COOLER

OR DIESEL FUELDFU - DRAINAGE FIXTURE UNITDI - DEIONIZED W ATERDIA - DIAMETERDIM - DIMENSIONDN - DOW NDS - DOW N SPOUT OR SPRINKLER (DRY)DT - PERFORATED DRAIN TILEDW G - DRAW ING

EA - EACHEC - ELECTRICAL CONTRACTOR (DIVISION 26)EEW - EMERGENCY EYE W ASHEJ - EXPANSION JOINTELEC - ELECTRICALELEV - ELEVATOREQ - EQUALEQUIP - EQUIPMENTET - EXPANSION TANKETR - EXISTING TO REMAINES - EMERGENCY SHOW EREQS - EQUIPMENT SUPPLIEREW C - ELECTRICAL W ATER COOLEREXH - EXHAUST AIREXP - EXPANSIONEXT - EXTERIOREX - EXISTING

F - FIRE SUPPRESSION (STANDPIPE/SPRINKLER MAIN)FCE - FIRE CONTROL EQUIPMENTFCO - FLOOR CLEANOUTFD - FLOOR DRAINFDC - FIRE DEPARTMENT CONNECTIONFDV - FIRE DEPARTMENT VALVEFF - FINISHED FLOOR ELEVATIONFHC - FIRE HOSE CABINETFLR - FLOORFM - FORCE MAINFOB - FLAT ON BOTTOM

FOF - FUEL OIL FLOWFOG - FUEL OIL GAUGEFOR - FUEL OIL RETURNFOS - FUEL OIL SUPPLYFOT - FLAT ON TOPFPM - FEET PER MINUTEFR - FIRE RISERFS - FLOOR SINK OR FIRE SERVICEFSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21)FT - FEETFTG - FOOTING

G - GAS OR NATURAL GASGA - GAUGEGAL - GALLONGALV - GALVANIZEDGC - GENERAL TRADES CONTRACTORGD - GARAGE DRAINAGEGPM - GALLONS PER MINUTEGS - GAS SERVICEGW - GREASE W ASTE

H2 - HYDROGENHB - HOSE BIBBHC - HVAC CONTRACTOR (DIVISION 23)HD - HUB DRAINHE - HELIUMHG - REFRIGERANT HOT GASHP - HORSEPOW ER OR HIGH POINTHPC - H IGH PRESSURE CONDENSATE RETURNHPS - H IGH PRESSURE STEAM SUPPLYHPW - HIGH PURITY W ATERHPW R - HIGH PURITY W ATER RETURNHR - HOSE REELHT - HEAT TRACEHTR - HEATERHVAC - HEATING, VENTILATING, AND AIR CONDITIONINGHW - HOT W ATERHW R - HEATING HOT W ATER RETURNHW S - HEATING HOT W ATER SUPPLY

IA - MEDICAL INSTRUMENT AIRID - INSIDE DIAMETERINV - INVERT ELEVATIONIN - INCHESIV - INDIRECT VENTIW - INDIRECT W ASTE

JS - JANITOR SINK

K - KITCHEN W ASTEKEC - KITCHEN EQUIPMENT CONTRACTOR

L - LENGTHLA - LABORATORY COMPRESSED AIRLAV - LAVATORYLBS - POUNDSLCW - LABORATORY COLD W ATERLEC - LABORATORY EQUIPMENT CONTRACTORLHW - LABORATORY HOT W ATERLHW R - LABORATORY HOT W ATER RETURNLPC - LOW PRESSURE CONDENSATE RETURNLPS - LOW PRESSURE STEAM SUPPLYLV - LABORATORY VACUUM OR LABORATORY VENTLW - LABORATORY W ASTE

MA - MEDICAL COMPRESSED AIRMAP - MASTER ALARM PANEL (MEDICAL GAS)MAX - MAXIMUMMB - MOP BASINMC - MECHANICAL CONTRACTOR (DIVISION 23)MEZZ - MEZZANINEMFR - MANUFACTURERMH - MANHOLEMIN - MIN IMUM OR MINUTEMISC - MISCELLANEOUSMTD - MOUNTEDMTG - MOUNTINGMPC - MEDIUM PRESSURE CONDENSATE RETURNMPS - MEDIUM PRESSURE STEAM SUPPLYMU - W ATER MAKE-UPMV - MEDICAL SURGICAL VACUUM

N2 - MEDICAL N ITROGENN/C - NORMALLY CLOSEDNG - GASOLINE (NON-LEAD)NIC - NOT IN CONTRACTN/O - NORMALLY OPENNO - MEDICAL N ITROUS OXIDENOM - NOMINALNPW - NON-POTABLE W ATERNPT - NATIONAL PIPE THREADNTS - NOT TO SCALE

02 - MEDICAL OXYGENOA - OUTDOOR AIROD - OUTSIDE D IAMETER OR OVERFLOW DRAINOFCI - OW NER FURNISHED CONTRACTOR

INSTALLEDOFOI - OW NER FURNISHED OW NER INSTALLED

P - PROPANE GASPC - PLUMBING CONTRACTOR (DIVISION 22)

OR PUMPED CONDENSATE RETURNPD - PUMP DISCHARGE OR PARAPET DRAINPIV - POST INDICATOR VALVEPLBG - PLUMBINGPS - PRE-ACTION/DELUGE SPRINKLER PRESS - PRESSUREPRV - PRESSURE REGULATING VALVEPSF - POUNDS PER SQUARE FOOTPSI - POUNDS PER SQUARE INCHPSV - PRESSURE SUSTAINING VALVEPSIG - POUNDS PER SQUARE INCH GAUGEPW - PURE W ATER

RA - RETURN AIRRAD - RADIUSRCP - REINFORCED CONCRETE PIPERD - ROOF DRAINREC - RECESSEDREQD - REQUIREDRI - ROUGH INRL - REFRIGERANT LIQUIDROS - REVERSE OSMOSIS W ATER SUPPLYROR - REVERSE OSMOSIS W ATER RETURNRPM - REVOLUTIONS PER MINUTERS - REFRIGERANT SUCTIONRV - RELIEF VALVE

S - SPRINKLER (W ET)SA - SHOCK ARRESTOR OR SUPPLY AIRSAN - SANITARY OR SANITARY DRAINSCH - SCHEDULESCW - SOFT COLD W ATERSD - SPRINKLER DRAIN OR SUBSOIL DRAINSH - SHOW ERSHT - SHEETSK - SINKSPEC - SPECIFICATIONSSQ - SQUARESR - SUPPLY RISERSS - SANITARY STACK (SOIL OR W ASTE) OR

STAINLESS STEELSTD - STANDARDSTM - STORM OR STORM DRAINAGESTRUC - STRUCTURAL OR STRUCTURESUC - SITE UTILITY CONTRACTOR

T - FUEL TANK VENTTD - TRENCH DRAINTEMP - TEMPERATURETOB - TOP OF BEAMTOD - TOP OF DUCTTOE - TOP OF EQUIPMENTTOF - TOP OF FOOTINGTOJ - TOP OF JOISTTOP - TOP OF PIPETOS - TOP OF SLAB OR TOP OF STEELTF - TRAP FILLERTP - TRAP PRIMER OR TRAP PRIMER DISCHARGETW - TEMPERED W ATERTYP - TYPICAL

UR - URINALUNO - UNLESS NOTED OTHERW ISE

V - VENT OR SANITARY SEW ER VENTVAC - VACUUMVC - VACUUM CLEANINGVCV - VACUUM CLEANING VALVEVE - VACUUM EXHAUSTVEL - VELO CITYVIB - VALVE IN BOXVOL - VOLUMEVP - VACUUM PUMPVS - VENT STACKVTR - VENT THROUGH ROOFVR - VENT RISER

W / - W ITHW /0 - W ITHOUTW - W ASTEW AGD - W ASTE ANESTHESIA GAS DISPOSALW C - W ATER CLOSETW CO - W ALL CLEANOUTW H - W ALL HYDRANT OR W ATER HEATERW IV - W ALL INDICATOR VALVEW S - W ATER SERVICE

YCO - YARD CLEANOUT

ZVC - ZONE VALVE CABINET

PIPE RISER

NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT

TO MODIFICATIONS ON OTHER DRAWINGS.

ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT

NECESSARILY BE USED ON THIS PROJECT.

GENERAL NOTES

A ALL PIPING IS ABOVE THE CEILING (AT THE UNDERSIDE OF STRUCTURE IN EXPOSED STRUCTURE AREAS), UNLESS OTHERW ISE NOTED.

B REFER TO SCHEDULES, DETAILS AND DIAGRAMS FOR PIPING, PIPE SIZES AND PIPELINE DEVICES NOT INDICATED ON THE FLOOR PLAN.

C ABOVE CEILING UTILITY SPACE IS LIMITED. COORDINATION W ITH ALL TRADES IS CRITICAL, PRIOR TO INSTALLATION ON ANY W ORK.

D LOCATIONS AND SIZES OF EXISTING PIPING HAVE BEEN DETERMINED FRO M A REVIEW OF EXISTING DRAW INGS AND/OR SITE INSPECTION, W HERE POSSIBLE. FIELD VERIFICATION OF EXACT LOCATIONS, ELEVATIONS, INVERTS, SIZES, DIRECTION OF FLOW , ETC. SHALL BE REQUIRED PRIOR TO BEGINNING NEW W ORK.

E ALL PIPING SHALL BE REMOVED BACK TO ACTIVE MAINS AND CAPPED, OR REMOVED BACK TO POINTS OF CONNECTION IN NEW W ORK. DOMESTIC W ATER PIPING SHALL BE REMOVED BACK TO W ITHIN 2 PIPE DIAMETERS OF ACTIVE BRANCH/MAIN. NO DEADLEGS SHALL REMAIN. INACCESSIBLE PIPING, W HERE SO NOTED, TO BE ABANDONED SHALL BE DISCONNECTED FROM ACTIVE SYSTEMS AND CAPPED OR PLUGGED IN CONCEALED LOCATIONS. ALL ABANDONEDPIPING SHALL BE CAPPED AT INLET AND OUTLET.

F NEW CONNECTIONS TO EXISTING PIPING SHALL BE W ITH THE SAME SIZE AS THE EXISTING PIPING, UNLESS OTHERW ISE NOTED.

G ALL REMOVED MATERIAL AND EQUIPMENT, SO DESIGNATED BY THE OW NER, SHALL BE TURNED OVER AND PLACED W HERE DIRECTED. ALL MATERIAL AND EQUIPMENT, W HICH THE OW NER DOES NOT W ISH TO RETAIN, SHALL BECOME THE PROPERTY OF THE CONTRACTOR RESPONSIBLE FOR THE REMOVAL.

H REFER TO THE ARCHITECTURAL PLANS FOR PROJECT PHASING REQUIREMENTS.

I ANNULAR SPACE OF PIPE, CONDUIT AND OTHER SIMILAR PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE FIRESTOPPED. IN ADDITION, PENETRATIONS THRU RATED FLOORS SHALL ALSO BE FIRESTOPPED TO RETARD PASSAGE OF FIRE ANDSMOKE. REFER TO SPECIFICATIONS. REFER TO ARCHITECTURAL DRAW ING(S) FOR CONSTRUCTION, LAYOUT AND FIRE RATINGS OF FLOORS, W ALLS, PARTITIONS AND OTHER BUILDING ELEMENTS. REFER TO ARCHITECTURAL DRAW INGS FOR PENETRATION DETAILS.

J MEDICAL GAS SUPPLY PIPING SHALL BE MIN IMUM 0.5” SIZE. MEDICAL VACUUM ANDW ASTE ANETHESIA GAS DISPOSAL PIPING SHALL BE MINIMUM 0.75" SIZE.

K ALL MEDICAL GAS SYSTEM INSTALLERS SHALL BE CERTIFIED TO THE REQUIREMENTS OF ASSE 6010. ALL MEDICAL GAS SYSTEM VERIFIERS SHALL BE CERTIFIED TO THE REQUIREMENTS OF ASSE 6030.

L MEDICAL GAS AND VACUUM SYSTEM INSTALLATION AND VERIFICATION SHALL COMPLY W ITH THE REQUIREMENTS OF NFPA 99, GAS AND VACUUM SYSTEMS,2012 EDITION.

FIRE SUPPRESSION DESIGN NOTES

A REFER TO ARCHITECTURAL DRAW INGS FOR LIMITS OF CONSTRUCTION. COORDINATE SPRINKLER LOCATIONS W ITH CEILING DEVICES (LIGHTING, GRILLES, ETC.) REFER TO PLUMBING DRAW INGS, PLAN NOTES AND GENERAL NOTES FOR ALL W ORK ASSOCIATED W ITH THE FIRE SUPPRESSION CONTRACT.

B FIRE SUPPRESSION SPRINKLER SYSTEMS. REFER TO DRAW INGS ANDSPECIFICATIONS FOR COMPLETE SCOPE OF W ORK.

1 RENOVATION AREA(S) TO BE TOTALLY SPRINKLERED. EXISTINGSPRINKLER SYSTEMS TO BE MODIFIED AND/OR EXTENDED TO CONFORM TO THE NEW LAYOUT. NEW SPRINKLERS ARE TO BE INTEGRATED INTO THE EXISTING SPRINKLER SYSTEM. PROVIDE NEW SPRINKLER ZONE CONTROL VALVE IF NECESSARY. ALL EXISTING SPRINKLERS, REMOVED OR DISTURBED IN RENOVATION AREAS, SHALL BE DISPOSED OF AND REPLACED W ITH NEW SPRINKLERS, ASINDICATED ON THE DRAW INGS.

C BASIS FOR DESIGN OF FIRE SUPPRESSION SYSTEMS TO BE LIGHT HAZARD OCCUPANCY, EXCEPT MECHANICAL ROOMS, STORAGE ROOMS, AND OTHER AREAS REQUIRED BY CODE W HICH ARE ORDINARY GROUP 1;

1 LIGHT HAZARD: 1500 SQUARE FEET MIN. AREA OF OPERATION,0.10 GPM/SQ.FT. DENSITY, 225 SQUARE FEET MAXIMUM PERSPRINKLER. A 100 GPM TOTAL HOSE STREAM ALLOW ANCE ATSOURCE SHALL BE USED IN THE DESIGN.

2 ORDINARY HAZARD (GROUP 1): 1500 SQUARE FEET MIN. AREA OFOPERATION, 0.15 GPM/SQ.FT. DENSITY, 130 SQ. FT. MAX. PERSPRINKLER. A 250 GPM TOTAL HOSE STREAM ALLOW ANCE ATSOURCE SHALL BE USED IN THE DESIGN.

3 AREA OF OPERATION REDUCTIONS AND INCREASES SHALL BECALCULATED PER NFPA STANDARDS. VERIFY DENSITIES W ITHGOVERNING AUTHORITIES AND OW NER’S INSURER BEFOREPROCEEDING W ITH DESIGN OF SYSTEM(S). IF GOVERNINGAUTHORITIES OR OW NER’S INSURER REQUIREMENTS ARE MORESTRINGENT THOSE REQUIREMENTS SHALL PREVAIL.

D SPRINKLERS SHALL BE LOCATED IN THE CENTER OF SQUARE PADS AND AT THE CENTER OR AT QUARTERPOINTS OF THE LONG AXIS OF RECTANGULAR PADS.

1 SPRINKLERS IN AREAS W ITHOUT CEILINGS SHALL BE QUICKRESPONSE BRASS UPRIGHT OR QUICK RESPONSE PENDENT TYPE.

2 SPRINKLERS IN AREAS W ITH CEILINGS SHALL BE QUICK RESPONSETW O-PIECE ADJUSTABLE CONCEALED PENDENT TYPE W ITH W HITECOVERPLATE.

E EXERCISE SPECIAL CARE TO COORDINATE PIPING AND EQUIPMENTLOCATIONS W ITH ALL OTHER TRADES.

F ALL NEW W ORK SHALL BE COMPLIANT W ITH RULES AND REGULATIONSOF NFPA-13 OR THE GOVERNING AUTHORITY IF MORE STRINGENT.

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

12" = 1'-0"

2019.05.24

E.P001

PLUMBING LEGEND,GENERAL NOTES AND

SHEET INDEX

05/24/19

W SM

DPB

PHE - SHEET LIST - PLUMBING

Sheet Number Sheet Name

E.P001 PLUMBING LEGEND, GENERAL NOTES AND SHEET INDEX

E.P002 PLUMBING SCHEDULES & DIAGRAM

E.P102 PARTIAL FIRST AND SECOND FLOOR PLANS

E.P103 PARTIAL THIRD FLOOR PLANS

1 2019.05.24 PERMIT SET

Page 2: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

1.5"

-V

NEW CAPS

NEW CAPS

B1

1.5"

-S

AN

NEW C APS

NEW C APS

NEW CAP

C1

2" - SA

N

1.5" - V

FD

FD2

FD1

3" - SAN

2"

A1

C1

B1

1.5"

1.5"

1.5"

2"

2"

4"

4"

A1

4" -

SA

N

4" -

V

4" - V5" - SAN

3" - SAN

3" -SAN

4" -V

1.5" - V

2" -V

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

2019.05.24

E.P002

PLUMBING SCHEDULES &DIAGRAM

05/24/19

W SM

DPB

NOTES:1. PROVIDE ADJUSTABLE STEEL OR CAST IRON FOOT SUPPORT CARRIER.2. PROVIDE ADA TRAP INSULATION KIT EQUAL AS MANUFACTURED BY TRUEBRO, McGUIRE OR PLUMBEREX.

3. MOUNT FLUSH VALVE HANDLE ON WIDE SIDE OF STALL PER ADA GUIDELINES.4. EXISTING SCRUB SINKS SHALL BE RELOACTED INCLUDING FAUCET, WASTE TRIM AND P-TRAP. PROVIDE NEW SUPPLY STOPS AS SCHEDULED.

5. PROVIDE ADDITIONAL BLOCKING IN WALLS AS REQUIRED TO SUPPORT FAUCET(S), ACCESSORIES AND/OR FIXTURE.6. COORDINATE MOUNTING OF ACCESSORIES WITH ARCHITECT.7. MOUNT SHOWER ELBOW HIGH ENOUGH THAT HAND SPRAY CAN HANG WITHOUT TOUCHING THE SHOWER BASIN.

ADA HANDICAP ACCESSIBLE FS FLOOR SET FT FLUSH TANK FV FLUSH VALVE GN GOOSENECK HS HAND SHOWER PB PRESSURE BALANCED

QD QUICK DISCONNECTSB SINGLE BOWLSST STAINLESS STEELVB VACUUM BREAKERVR VANDAL RESISTANTWB WRIST BLADEWH WALL HUNG

SCHEDULE ABBREVIATIONS: GENERAL NOTE:1. SUPPLY PIPE SIZES IN THIS SCHEDULE ARE FIXTURE OR SUPPLY STOP CONNECTION SIZES. DOMESTIC COLD AND HOT WATER SUPPLY PIPE SIZES SERVING FIXTURES SHALL BE, AT A MINIMUM, THE SIZES LISTED UNLESS NOTED OTHERWISE OR LABELED ON THE FLOOR PLANS. DOMESTIC COLD WATER SUPPLY PIPE SIZES SERVING FLUSH VALVES SHALL BE AT MINIMUM ONE PIPE SIZE LARGER THAN THE INDICATED CONNECTION SIZE, OR SIZED AS SHOWN ON THE FLOOR PLANS. PIPING AT THE FLUSH VALVE CONNECTION OF A SIZE EQUAL TO THE CONNECTION SIZE SHALL BE LIMITED TO A MAXIMUM 2 FEET IN DEVELOPED LENGTH AND INCLUDE A MAXIMUM OF ONE 90 DEGREE ELBOW FITTING. FULL SIZE MANIFOLDS, WHERE INDICATED ON THE FLOOR PLANS, SHALL BE PROVIDED FULL SIZE FOR THE LENGTH OF THE PIPING CHASE AND TERMINATED WITH A FULL SIZE CAP.

A. AMERICAN STANDARD (KOHLER, CRANE, ZURN) _

B. SLOAN (DELANY, ZURN) _

C. BEMIS (BENEKE, CHURCH, OLSONITE) _

D. SMITH (WADE, ZURN, JOSAM, WATTS) _

E. CHICAGO (TOTO, T&S BRASS, ZURN) _

F. GUY GRAY (OATEY, PLASTIC ODDITIES) _

G. McGUIRE (EBC, DEARBORN BRASS) _

H. WILLOUGHBY (SLOAN, WHITEHALL) _

J. ELKAY (WILLOUGHBY, SLOAN. WHITEHALL) _

K. HALSEY TAYLOR (ACORN, ELKAY, HAWS, OASIS) _

L. SYMMONS (POWERS, LEONARD) _

M. AQUARIUS (AQUA-BATH, KOHLER, CRANE) _

N. IN-SINK ERATOR (OR APPROVED EQUAL) _

_

_

_

CATALOG NUMBERS INDICATED ARE THOSE OF THE FIRST NAMED MANUFACTURER IN EACH CATEGORY LISTED BELOW - ADDITIONAL MANUFACTURERS ARE LISTED IN PARENTHESIS

PLUMBING FIXTURES

MARK DESCRIPTION MO

UN

TIN

G H

EIG

HT

FLOW CONTROL SUPPLY WASTE & VENT FIXTURE SUPPLY TRIM SUPPLY / STOP WASTE TRIM TRAP / FIX. DR. MISC.

SE

E N

OT

E

GP

M

GP

F

MA

NU

AL

ME

TE

RIN

G

SENSOR

CO

LD

WA

TE

R

HO

T W

AT

ER

TE

MP

ER

ED

NA

T.

GA

S

FIX

. O

UT

LE

T

TR

AP

FIX

. D

RA

IN

WA

ST

E-M

IN.

VE

NT

-MIN

.

IN

DIR

EC

T

AIR

GA

P

AIR

BR

EA

K

MF

R.

CAT. NO. MF

R.

CAT. NO. MF

R.

CAT. NO. MF

R.

CAT. NO. MF

R.

CAT. NO. MF

R.

CAT. NO. EL

EC

TR

IC

BA

TT

ER

Y

A1 WATER CLOSET/ WH/ FV/ ADA 16.5TORIM

1.6 ● 1" 4" INT 4" 4" 2" A 2257.101 B 111-1.6-YO-SG

B UNIT A UNIT A INTEGRAL C 1655SSCT 1, 3

B1 LAVATORY/ WH/ GN/ WB/ ADA 34" TORIM

1.5 ● 0.5" 0.5" 1.25" 1.5" 1.5" 1.5" 1.5" A 0356.015 E 786-GN2FCXKABCP

G LFBV2165 G 155WC G 8912 1, 2

C1 URINAL/ WH/ FV/ ADA PERARCH

1.0 ● 0.75"

2" INT 2" 2" 1.5" A 6590.001 B 180-1.0-SG B UNIT A UNIT A INTEGRAL 1

D1 SCRUB SINK/ RELOCATED 36" TORIM

2.2 ● 0.5" 0.5" 1.5" 1.5" 1.5" 1.5" 1.5" - RELOCATED - RELOCATED G LFBV2165 - RELOCATED - RELOCATED 4

J1 SHOWER/ BUILT UP/ PB/ HS/ QD/ VB/ ADA PERARCH

2.5 ● 0.5" 0.5" - BY OTHERS L S-9603-PLR-CHKS-R-QD-

VB

- BALLVALVE(S)

- FLOORDRAIN

- ROUGH 5, 6, 7

NOTES:1. COORDINATE INSTALLATION OF FLOOR DRAIN WITH GC & CM TO ENSURE A WATERPROOF INSTALLATION.

GENERAL NOTE:1. ALL DRAINS ARE MANUFACTURED BY J.R. SMITH UNLESS NOTED OTHERWISE.

DRAINS

MARK CATALOG NOS.

TYPE BODY OUTLET STRAINER / GRATE TOP FINISH ADDITIONAL FEATURES

SE

E N

OT

E

FL

OO

R

RO

OF

AR

EA

WA

Y

CA

ST

IR

ON

BR

AS

S

AC

ID R

ES

IST

.

ST

AIN

LE

SS

ST

EE

L

PL

AS

TIC

SIZ

E

BO

TT

OM

SID

E

SIZE

AD

JU

ST

AB

LE

FL

AT

DO

ME

RE

CE

SS

ED

FU

NN

EL

HIN

GE

D

ST

AIN

LE

SS

ST

EE

L

NIC

KL

E-B

RO

NZ

E

CA

ST

IR

ON

AC

ID R

ES

IST

.

ST

AIN

LE

SS

ST

EE

L

PL

AS

TIC

DU

CT

ILE

IR

ON

AN

CH

OR

FL

AN

GE

FL

AS

HIN

G C

LA

MP

DB

L D

RA

INA

GE

SE

D.

BU

CK

ET

AU

X.

ST

RA

INE

R

BE

AR

ING

PA

N

U'D

EC

K C

LA

MP

2"

ST

AN

DP

IPE

TR

AP

PR

IME

R C

ON

.

WA

TE

R D

AM

DIA

ME

TE

R / W

IDT

H

LE

NG

TH

FD1 2005-A ● ● 3" ● 5" ● ● ● ● ● ● 1

FD2 2005-A ● ● 2" ● 5" ● ● ● ● ● ● 1

SCALE: NONE

SANITARY WASTE AND VENT DIAGRAM - 2ND FLOOR TOILET ROOM1

1 2019.05.24 PERMIT SET

Page 3: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

2515

WOMEN'S

TLT.

146

2519

MEN'S

TLT.

149

3 4

H

SAN

SS SS

2

2

2

2

3 4

LAV

LAV

LAV

LAV

LAV

LAVFD 1

3W C

3W C

3W C

W C

3 W C

W C

3 UR

3 UR

3 UR

ETR MB

FD 7

6

2.5" - DCW

0.75" - DCW0.75" - DHW 0.75" - DHW 1.5" - DCW

4" - V

3

3

5ETR 4" VS ETR 4" SS

3 4

H

SAN

ETR 6" DS DN

ETR AV ETR SS DN

SS SS

DS

NEW CAP

CO

DS

ST

M

6"

FD1

D1

2.5" - DCW

0.75" - DCW0.75" - DHW 0.75" - DHW 1.5" - DCW

FD

1

0.5"

0.5" FD2

FD1

B1

C1

A1

A1

B1

ETR MB

9 ETR 4" SS

0.75"

C1

10

NEW CAPS

NEW CAPS

J1

11

12

12

12 12

0.75"

2515

STAFF

TOILET RM

2519

UNISEX

TOILET RM.

2519ACLOSET

4" - V

OH1

3 4

H

LAV

LAV

LAV

FD

FD

SS

LAV

LAV

M B

DF

ETR SS DN

ETR VS UP

VR

8

8

5

8

3 4

H

FD

M B

VR

FD2 FD1

C1

SS

ETR SS DN

ETR VS UP

NEW CAPS

NEW CAPS

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

3/16" = 1'-0"

2019.05.24

E.P102

PARTIAL FIRST ANDSECOND FLOOR PLANS

05/24/19

W SM

DPB

SCALE: 3/16" = 1'-0"

PARTIAL SECOND FLOOR PLAN - REMOVALS1

SCALE: 3/16" = 1'-0"

PARTIAL SECOND FLOOR PLAN - NEW WORK2

SCALE: 3/16" = 1'-0"

PARTIAL FIRST FLOOR PLAN - REMOVALS3

SCALE: 3/16" = 1'-0"

PARTIAL FIRST FLOOR PLAN - NEW WORK4

NOTES

1 EXISTING FLOOR DRAIN TO REMAIN.

2 DISCONNECT AND REMOVE EXISTING PLUMBING FIXTUREINCLUDING ALL ACCESSORIES. REMOVE EXISTING DOMESTICWATER PIPING BACK TO POINT OF RECONNECTION OR WITHINTWO (2) PIPE DIAMETERS OF ACTIVE MAIN AND CAP. REMOVEEXISTING SANITARY PIPING TO BEYOND FINISHED WALL AND CAP.NO PIPE STUBS SHALL BE VISIBLE IN FINISHED SPACE.

3 DISCONNECT AND REMOVE EXISTING PLUMBING FIXTUREINCLUDING ALL ACCESSORIES, CARRIERS, DOMESTIC WATER,SANITARY AND VENT PIPING BACK TO ACTIVE BRANCH/MAIN ANDCAP.

4 DISCONNECT AND REMOVE EXISTING PLUMBING FIXTUREINCLUDING ALL ACCESSORIES. REMOVE EXISTING DOMESTICWATER PIPING BACK TO POINT OF RECONNECTION. EXISTINGSANITARY PIPING TO BE MODIFIED AS REQUIRED TO SERVE NEWLAVATORY. REFER TO NEW WORK PLAN.

5 DISCONNECT, REMOVE AND REROUTE EXISTING SANITARYSTACK. REFER TO NEW WORK PLAN.

6 DISCONNECT AND REMOVE EXISTING DOMESTIC WATER,SANITARY AND VENT PIPING INSIDE CHASE BACK TO POINT OFRECONNECTION. REFER TO NEW WORK PLAN.

7 DISCONNECT AND REMOVE EXISTING FLOOR DRAIN. REMOVEEXISTING SANITARY PIPING BACK TO POINT OF RECONNECTION.REFER TO NEW WORK PLAN. COORDINATE PATCHING OF FLOORWITH GC AND CM.

8 DISCONNECT AND REMOVE EXISTING SANITARY PIPING SERVINGDEMOLISHED FIXTURE ABOVE BACK TO POINT OFRECONNECTION OR ACTIVE BRANCH/MAIN AND CAP. REFER TONEW WORK PLAN.

9 REROUTE EXISTING SANITARY STACK THROUGH NEW WATERCLOSET CARRIER.

10 CONNECT NEW LAVATORY TO EXISTING SANITARY ROUGH-IN.MODIFY EXISTING SANITARY ROUGH-IN AS REQUIRED.

11 PROVIDE 2" FULL SIZE DCW MANIFOLD ENTIRE LENGTH OFPLUMBING CHASE AND SERVE EACH FIXTURE INDIVIDUALLYFROM MANIFOLD.

12 MODIFY EXISTING "WET PIPE" FIRE SUPPRESSION SYSTEM ASREQUIRED TO ACCOMMODATE PROPOSED RENOVATIONS.

1 2019.05.24 PERMIT SET

Page 4: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

V V

1000mm ARM

850mm ARM

1300mm ARM

1400

mm

ARM

1400mm ARM

1300mm A RM

1400

mm

ARM

1300

mm

AR

M

1400mm ARM

1300mm A RM

-

3515B

HM

2

3" SOFFI

T

2

3" SOFFI

T

2

3" SOFFI

T

2

3" SOFFI

T

2 3" SQ.

23"

SQ.

3

N2

N1

3 4

H

J

1

ETR SAN DN

ETR 4" DS DN

SKSK

6" STM DN

6" STM UP

SKZVC

SUITEAAP

0.75" - O21.25" - MV

0.75" - MA

FD1

0.5" - DHW R0.5" - DHW

0.5" - DCW

0.5" - DHW R0.75" - DHW

0.75" - DCW

3 4

H

J

ETR SAN DN

SKSK

0.5" - DCW

ETRFVC

1.25" - MV0.75" - O2

0.75" - MA

6" STM DN

SUITEAAP

FD1

6" STM UP

0.5" - MA

0.5" - O2

1.25" - MV

4

ZVC

D1 D12

3

SK

ANESTHESIA BOO M(2) MA(2) O2(2) MV(1) W AGD

EQUIPMENT BO OM(1) O2(1) MA(3) MV

5

5

0.5"

-O

2

0.75

" -

MV

0.5"

-M

A

0.5" - O20.5" - MA

1" - MV0.75" - W AGD

0.75" - MV

ZVC

0.5"

-M

A1.

25"

-M

V0.

5" -

O2

0.5" - DHW R0.5" - DHW

0.5" - DHW R0.75" - DHW

0.75" - DCW

CONTROL RM.

3517

CATH LAB #4

3515

3520

EQUIPMENT/

SUPPLY

ETR 4" DS DN

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

3/16" = 1'-0"

2019.05.24

E.P103

PARTIAL THIRD FLOORPLANS

05/24/19

W SM

DPB

SCALE: 3/16" = 1'-0"

PARTIAL THIRD FLOOR PLAN - REMOVALS1

SCALE: 3/16" = 1'-0"

PARTIAL THIRD FLOOR PLAN - NEW WORK2

NOTES

1 DISCONNECT, REMOVE AND RELOCATE EXISTING SCRUB SINKSINCLUDING FOOT SUPPORT CARRIER, WASTE TRIM, P-TRAP ANDFAUCET. REMOVE EXISTING DOMESTIC WATER, SANITARY ANDVENT PIPING AS REQUIRED FOR RECONNECTION TO SCRUBSINKS IN NEW LOCATION. REFER TO NEW WORK PLAN.

2 INSTALL RELOCATED SCRUB SINK, FAUCET, WASTE TRIM, P-TRAPAND FOOT SUPPORT CARRIER. PROVIDE NEW SUPPLY STOPS,McGUIRE #LFBV2165. RECONNECT TO EXISTING DOMESTICWATER, SANITARY AND VENT PIPING.

3 ROUTE SANITYARY PIPING THROUGH WALL AND RECONNECT TOEXISTING SANITARY DROP TO FLOOR BELOW.

4 CONNECT TO EXISTING MEDICAL GAS/VACUUM MAINS INCORRIDOR AND EXTEND NEW MA, O2 AND MV BRANCHES TO NEWZVC.

5 MAKE CONNECTION TO PIPE STUBS PROVIDED WITH BOOM.VERIFY EXACT PIPE SIZES, LOCATIONS AND REQUIREMENTSWITH BOOM SUPPLIER.

1 2019.05.24 PERMIT SET

Page 5: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

NOTE: ALL SYMBOLS AND ABBREVIATIONS

ARE SUBJECT TO MODIFICATIONS

ON OTHER DRAWINGS.

ALL SYMBOLS OR ABBREVIATIONS

MIGHT NOT NECESSARILY BE USED ON

THIS PROJECT.

ABBREVIATIONS

AC - AIR COMPRESSOR OR AIR CONDITIONERACCU - AIR COOLED CONDENSING UNITAD - ACCESS DOOR OR AREA DRAINADJ - ADJUSTABLEAFF - ABOVE FINISHED FLOORAFG - ABOVE FINISHED GRADEAFMS - AIR FLOW MEASURING STATIONALT - ALTERNATEAP - ACCESS PANELAPPROX - APPROXIMATEARCH - ARCHITECT OR ARCHITECTURALASSY - ASSEMBLYATC - AUTOMATIC TEMPERATURE CONTROL

BDD - BACK DRAFT DAMPERBFP - BACKFLOW PREVENTERBLDG - BUILD INGBOB - BOTTOM OF BEAMBOD - BOTTOM OF DUCTBOE - BOTTOM OF EQUIPMENTBOF - BOTTOM OF FOOTINGBOG - BOTTOM OF GRILLEBOP - BOTTOM OF PIPEBOT - BOTTOMBTU - BRITISH THERMAL UNITBTUH - BRITISH THERMAL UNIT PER HOUR

CBD - COUNTER BALANCED BACKDRAFT DAMPERCFCI - CONTRACTOR FURNISHED CONTRACTOR

INSTALLEDCFM - CUBIC FEET PER MINUTECHS - CHILLED W ATER SUPPLYCHR - CHILLED W ATER RETURNCHGR - CHILLED W ATER GLYCOL SOLUTION RETURNCHGS - CHILLED W ATER GLYCOL SOLUTION SUPPLYCLG - CEILINGCMU - CONCRETE MASONRY UNITCO - CLEAN OUTCO2 - CARBON DIOXIDECONN - CONNECT OR CONNECTIONCONTR - CONTRACTORCTR - CENTERCU - COPPERCW - COLD W ATERCW R - CONDENSER W ATER RETURNCW S - CONDENSER W ATER SUPPLY

D - DRAIN LINEDB - DRY BULBDDC - D IRECT D IGITAL CONTROLSDI - DEIONIZED W ATERDIA - D IAMETERDIM - D IMENSIONDN - DOW NDW G - DRAW ING

EA - EACH OR EXHAUST AIREAT - ENTERING AIR TEMPERATUREEC - ELECTRICAL CONTRACTOR (DIVISION 26)EJ - EXPANSION JOINTELEC - ELECTRICALELEV - ELEVATOREQUIP - EQUIPMENTET - EXPANSION TANKETR - EXISTING TO REMAINEQS - EQUIPMENT SUPPLIEREW T - ENTERING W ATER TEMPERATUREEXH - EXHAUSTEXP - EXPANSIONEXT - EXTERIOREX - EXISTING

FD - FLOOR DRAINFF - FINISHED FLOOR ELEVATIONFLR - FLOORFOB - FLAT ON BOTTOMFOF - FUEL OIL FLOWFOG - FUEL OIL GAUGEFOR - FUEL OIL RETURNFOS - FUEL OIL SUPPLYFOT - FLAT ON TOPFPM - FEET PER MINUTEFSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21)FT - FEETFTG - FOOTING

G - GAS OR NATURAL GASGA - GAUGEGAL - GALLONGALV - GALVANIZEDGC - GENERAL TRADES CONTRACTORGPM - GALLONS PER MINUTE

HB - HOSE BIBBHC - HVAC CONTRACTOR (DIVISION 23)HD - HUB DRAINHG - REFRIGERANT HOT GASHP - HORSEPOW ERHPC - H IGH PRESSURE CONDENSATE RETURNHPS - H IGH PRESSURE STEAM SUPPLYHR - HOURHT - HEAT TRACEHTR - HEATERHVAC - HEATING, VENTILATING, AND AIR CONDITIONINGHW - HOT W ATERHW R - HEATING HOT W ATER RETURNHW S - HEATING HOT W ATER SUPPLY

ID - INSIDE DIAMETERINV - INVERT ELEVATIONIN - INCHES

KEC - KITCHEN EQUIPMENT CONTRACTOR

L - LENGTHLAT - LEAVING AIR TEMPERATURELAV - LAVATORYLBS - POUNDSLPC - LOW PRESSURE CONDENSATE RETURNLPS - LOW PRESSURE STEAM SUPPLYLW T - LEAVING W ATER TEMPERATURE

MAX - MAXIMUMMDD - MOTORIZED DAMPERMEZZ - MEZZANINEMFR - MANUFACTURERMH - MANHOLEMIN - MIN IMUM OR MINUTEMISC - MISCELLANEOUSMTD - MOUNTEDMTG - MOUNTINGMPC - MEDIUM PRESSURE CONDENSATE

RETURNMPS - MEDIUM PRESSURE STEAM SUPPLYMU - W ATER MAKE-UP

N/C - NORMALLY CLOSEDNIC - NOT IN CONTRACTN/O - NORMALLY OPENNOM - NOMINALNPT - NATIONAL PIPE THREADNTS - NOT TO SCALE

OA - OUTDOOR AIROBD - OPPOSED BLADE DAMPEROD - OUTSIDE DIAMETEROFCI - OW NER FURNISHED CONTRACTOR

INSTALLEDOFOI - OW NER FURNISHED O W NER INSTALLED

P - PROPANE GASPC - PLUMBING CONTRACTOR (DIVISION 22)

OR PUMPED CONDENSATE RETURNPLBG - PLUMBINGPRESS - PRESSUREPRV - PRESSURE REGULATING VALVEPSF - POUNDS PER SQUARE FOOTPSI - POUNDS PER SQUARE INCHPSIG - POUNDS PER SQUARE INCH GAUGE

RA - RETURN AIRRAD - RADIUSRCP - REFLECTED CEILING PLANRD - ROOF DRAINREC - RECESSEDREQD - REQUIREDRI - ROUGH INRL - REFRIGERANT LIQUIDROS - REVERSE OSMOSIS W ATER SUPPLYROR - REVERSE OSMOSIS W ATER RETURNRPM - REVOLUTIONS PER MINUTERS - REFRIGERANT SUCTIO N

S - SPRINKLER (W ET)SA - SUPPLY AIRSAN - SANITARY OR SANITARY DRAINSCH - SCHEDULESCW - SOFT COLD W ATERSHT - SHEETSPEC - SPECIFICATIONSSQ - SQUARESR - SUPPLY RISERSRV - SAFETY RELIEF VALVESS - STAINLESS STEELSTD - STANDARDSTM - STORM OR STORM DRAINAGESTRUC - STRUCTURAL OR STRUCTURESUC - SITE UTILITY CONTRACTOR

TEMP - TEMPERATURETOB - TOP OF BEAMTOD - TOP OF DUCTTOE - TOP OF EQUIPMENTTOF - TOP OF FOOTINGTOJ - TOP OF JOISTTOP - TOP OF PIPETOS - TOP OF SLAB OR TOP OF STEELTYP - TYPICAL

UNO - UNLESS NOTED OTHERW ISE

V - VENTVAC - VACUUMVEL - VELO CITYVIB - VALVE IN BOXVOL - VOLUMEVTR - VENT THROUGH ROOFVR - VENT RISER

W / - W ITHW /0 - W ITHOUTW B - W ET BULBW CO - W ALL CLEANOUT

GENERAL FLOOR PLAN NOTES

PLAN NOTE. APPLIES ONLY TO THE SHEET W HICH IT IS SHOW N UNLESS NOTED OTHERW ISE.

DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.

3

3

A1EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK. LETTER DESIGNATIONS REFER TO SCHEDULES.

H1 H1OREQUIPMENT REFERENCE. LETTER DESIGNATION VARIES. REFER TO SCHEDULES.

2

1

H2

B

H2

RISER OR STACK NUMBER

DETAIL: B = DETAIL DESIGNATION H2 = SHEET W HERE DETAIL IS LOCATED

SECTION: 1 = SECTION DESIGNATION H2 = SHEET W HERE DETAIL IS LOCATED

A1 "UP TO" SYM BOL (ITEM ON FLOOR ABOVE)

APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP OR BOTTOM OF EQUIPMENT, UNLESS NOTED OTHERW ISE

10"

ELEV: 8' - 0"ELEV: 8' - 0"

TOD: 8' - 10"

BOD: 7' - 2"

20x20

20x20

APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP OR BOTTOM OF DUCTW ORK, UNLESS NOTED OTHERW ISE

APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO CENTERLINE OF PIPE, UNLESS NOTED OTHERW ISE

DL-1

UC-X DOOR UNDERCUT. X = HEIGHT OF UNDERCUT IN INCHES; 0.75 INCH UNDERCUT IF NO HEIGHT IS NOTED. COORDINATE W ITH GC.

DOOR LOUVER. 1 = SQUARE FEET OF LOUVER.

CONNECT TO EXISTING

HVAC PIPING DESIGNATIONS

CHILLED W ATER SUPPLY PIPECHS

CONDENSER W ATER SUPPLY PIPECW S

CONDENSER W ATER RETURN PIPECW R

DRAIN LINE. PITCH IN DIRECTION INDICATEDD

HEATING HOT W ATER SUPPLY PIPEHW S

HEATING HOT W ATER RETURN PIPEHW R

W ATER MAKE-UP PIPEMU

VENT PIPEV

REFRIGERANT LIQUID LINERL

REFRIGERANT SUCTION LINERS

EXPANSION TANK PIPEET

REFRIGERANT HOT GAS LINEHG

LOW PRESSURE CONDENSATE RETURN PIPELPC

LOW PRESSURE STEAM SUPPLY PIPELPS

M EDIUM PRESSURE CON DENSATE RETURN PIPEMPC

MEDIUM PRESSURE STEAM SUPPLY PIPEMPS

PUMPED CONDENSATE RETURN PIPEPC

HIGH PRESSURE CONDENSATE RETURN PIPEHPC

HIGH PRESSURE STEAM SUPPLY PIPEHPS

STEAM SUPPLY PIPE - NUMBER IND ICATES P.S.I.G.10

MISC SYMBOLS

DUCTWORK SYMBOLS

ROUND BRANCH DUCTW ORKCONICALFITTING

ACOUSTICFITTING

ACOUSTICFITTING

ADAD

D

R R

D

REC TANGULAR BR ANCH DUCTW ORK

SQUARE TEE W ITH TURNING VANES

NOTE: ALL SQUARE ELBOW S IN RECTANGULAR AND ROUND / OVAL DUCTW ORK SHALL BE PROVIDED W ITH TURNING VANES. REFER TO SPECIFICATIONS FOR ADDITIONAL DETAILS.

EXISTING DUCTW ORK TO REMOVED

RETURN AIR , RELIEF AIR, O R TRANSFER AIR DUCTW ORK. (UP AND DOW N) RADIUSED OR SQUARE W ITH TURNING VANES.SUPPLY AIR OR OUTDOOR AIR DUCTW ORK.(UP AND DOW N) RADIUSED OR SQUARE W ITH TURNING VANES.

EXHAUST AIR DUCTW ORK. (UP AND DOW N) RADIUSED OR SQUARE W ITH TURNING VANES.

RECTANGULAR AND ROUND / OVAL DUCTW ORK RISE / DROP W ITH 90° RADIUSED OR SQUARE ELBOW S AND TURNING VANES.

RADIUS ELBOW

90° SQUARE ELBOW (W ITH TURNING VANES)NOTE: ALL SQUARE ELBOW S IN RECTANGULAR AND ROUND DUCTW ORK SHALL BE PROVIDED W ITH TURNING VANES.

ACCESS DOOR OR PANEL

DUCTW ORK RISE IN DIRECTION OF AIR FLOW

DUCTW ORK DROP IN DIRECTION OF AIR FLOW

DUCTW ORK W ITH ACOUSTICAL LINER. LISTED DUCT SIZES ARE INSIDE CLEAR DIMENSIONS.

RECTANGULAR ROUND / OVAL

FLEXIBLE DUCTW ORK

FLEXIBLE CONNECTION

DUCTW ORK CONSTRUCTED OF SPECIAL MATERIAL AS NOTED

DIRECTION OF PITCH

RECTANGULAR DUCTW ORK DIMENSIONS(W x H), SYSTEM ABBREVIATION26x20 SA

ROUND DUCTW ORK DIMENSIONS (DIA), SYSTEM ABBREVIATION

26ø SA

OVAL DUCTW ORK DIMENSIONS (W x H), SYSTEM ABBREVIATION

26x20 OV SA

DUCTWORK DEVICE SYMBOLS

W ALL OR DUCTW ORK MOUNTED AIR DEVICE. SG1 = DESIGNATION (REFER TO AIR DEVICE SCHEDULE). 20x12 = DUCT CONNECTION SIZE (IN INCHES).300 = REQUIRED CFM. 9'-0" = MOUNTING HEIGHT FROM FLOOR TO BOTTOM OF GRILLE.

A310ø300

MANUAL BALANCING VALVE DAMPER W ITH LOCKING DEVICE

BDD = BACK DRAFT DAMPERCBD = COUNTER-BALANCED BACK DRAFT DAMPER

SD = SMOKE DAMPERFS = COMBINATION FIRE - SMOKE DAMPERMDD = MOTORIZED DAMPERAFMS = AIR FLOW MEASURING STATION

DUCT MOUNTED SMOKE DETECTOR. COORDINATE LOCATION.

HUMIDITY SENSOR - DUCT MOUNTED

SG120x12

300BOG : 9'-0"

XXX

A-D

XX

H

SD

SP

AIR DEVICE. A3 = DESIGNATION (REFER TO FLOOR PLANS AND AIR DEVICE SCHEDULE FOR VARIOUS DESIGNATIONS).10ø = NECK SIZE (IN INCHES). 300 = REQUIRED CFM. ALL AIR DEVICE DISCHARGE 4-W AY UNLESS NOTED W ITH FLOW ARROW S. AIR DEVICE SHOW N IS 2-W AY SIDE THROW . METHOD OF IDENTIFICATION ALSO APPLIES TO OTHER CEILING MOUNTED AIR DEVICES.

FIRE DAMPERA = TYPE (REFER TO FLOOR PLANS FOR VARIOUS TYPES)D OR S = DYNAMIC OR STATIC

STATIC PRESSURE SENSOR - DUCT MOUNTED

CCARBON DIOXIDE SENSOR - DUCT MOUNTED

STEMPERATURE SENSOR - DUCT MOUNTED

CHECK VALVE

T

P

FOB

FOT

SHUTOFF VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON APPLICATIONS)

CONCENTRIC PIPE REDUCER

ECCENTRIC PIPE REDUCER

PRESSURE GAUGE

TEMPERATURE GAUGE OR THERMOMETER

COMBINATION SHUTOFF AND BALANCING VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON APPLICATIONS)

VALVES AND FITTINGSSINGLE LINE

10"

TOE: 3' - 0"

BOE: 0' - 6"

CHILLED W ATER GLYCOL SOLUTION RETURN PIPECHGR

CHILLED W ATER GLYCOL SOLUTION SUPPLY PIPECHGS

CHILLED W ATER RETURN PIPECHR

SQUARE THROAT / RADIUS HEEL FITTINGS NOT ACCEPTABLE

PIPING SYMBOLSDOUBLE LINE SINGLE LINE

BOTTOM CONNECTION (45°)

BRANCH TEE CONNECTION (NOTE: BULLHEAD TEE'S ARE NOT PERMITTED)

DIRECTION OF PITCH

DROP

ELBOW DOW N

ELBOW UP

EXISTING PIPE TO BE REMOVED

EXISTING PIPE TO REMAIN

FLOW DIRECTION DESIGNATION

PUMP

RISE

TOP CONNECTION (45°)

TOP CONNECTION (90°)

BOTTOM CONNECTION (90°)

DD

RR

PIPE RISER

RADIUS'D BRANCH

RADIUS'D TEE

EXISTING DUCTW ORK TO REMAIN

UNLESS NOTED OTHERW ISE ON DRAW INGS, 15° MAX FOR DIVERGING, 30° MAX FOR CONVERGING TRANSITION

EMERGENCY SHUTOFF STATION. 46" MOUNTING HEIGHT UNLESS NOTED OTHERW ISE.

SPACE TEMPERATURE SENSOR / THERMOSTAT. W HEN W ALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA REQUIREMENTS. W HEN MOUNTED NEXT TO W ALL SW ITCH COORDINATE W ITH ARCHITECT.

T

DPDIFFERENTIAL PRESSURE SENSOR. W HEN W ALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA REQUIREMENTS. W HEN MOUNTED NEXT TO W ALL SW ITCH COORDINATE W ITH ARCHITECT.

HHUMIDITY SENSOR. W HEN W ALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA REQUIREMENTS. W HEN MOUNTED NEXT TO W ALL SW ITCH COORDINATE W ITH ARCHITECT.

CARBON DIOXIDE SENSOR. W HEN W ALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA REQUIREMENTS. W HEN MOUNTED NEXT TO W ALL SW ITCH COORDINATE W ITH ARCHITECT.

C

COCARBON MONOXIDE SENSOR. W HEN W ALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA REQUIREMENTS. W HEN MOUNTED NEXT TO W ALL SW ITCH COORDINATE W ITH ARCHITECT.

TEMPERATURE SENSOR. W HEN W ALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA REQUIREMENTS. W HEN MOUNTED NEXT TO W ALL SW ITCH COORDINATE W ITH ARCHITECT.

S

S TEMPERATURE SENSOR MOUNTED IN CEILING PLENUM.

STATIC PRESSURE SENSOR.SP

STRAINER W ITH A BLOW DOW N VALVE AND HOSE CONNECTION

DRAIN VALVE W ITH HOSE END CONNECTION

AUTOMATIC FLOW CONTROLLER W ITH P/T PLUG IN AND OUT

EXPANSION JOINT

MANUAL AIR VENT

AUTOMATIC AIR VENT

PRESSURE REDUCING VALVE

2 PORT AUTOMATIC CONTROL VALVE

3 PORT AUTOMATIC CONTROL VALVE

QUICK OPENING MANUAL VALVE

VACUUM BREAKER

NEEDLE VALVE

PRESSURE AND TEMPERATURE TEST PLUG

VACUUM GAUGE W ITH STOP

END CAP

GLOBE VALVE

SHUTOFF VALVE AND BOX

SHUTOFF VALVE ON RISER

A

M

M

N

V

VB

SOLENOID VALVES

SAFETY RELIEF VALVE. FOR HYDRONIC SYSTEMS PIPE DISCHARGE AIR GAPPED TO FLOOR DRAIN UNLESS NOTED OTHERW ISE. FOR STEAM SYSTEMS PIPE D ISCHARGE TO OUTDOORS.

W ATER METERM

PRESSURE G AUGE W ITH COCK AND SIPHON LOOP

BI-M ETALIC STEAM TRAP AND DRIP ASSEM BLY

THERMODYNAMIC STEAM TRAP AND DRIP ASSEMBLY

INVERTED BUCKET STEAM TRAP AND DRIP ASSEMBLY

FLOAT AND THERMOSTATIC STEAM TRAP AND DRIP ASSEMBLY

TH ERM OSTATIC STEAM TRAP AND DRIP ASSEM BLY

BM

TD

IB

FT

TS

FLOW M ETERF

UNION

CLEANOUT

STRAINER

AUTOMATIC PRESSURE INDEPENDENT CONTROL VALVE

M

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

12" = 1'-0"

2019.05.24

E.H001

HVAC LEGEND &GENERAL NOTES

05/24/19

IAS

M RM

GENERAL NOTES:(APPLIES TO ALL SHEETS)

A. REFER TO ARCHITECTURAL PLANS FOR PHASING SEQUENCING. ALL PHASING REQUIREMENTS SHALL BE AS D ICTATED BY THE CONSTRUCTION MANAGER.

B. FIELD VERIFY EXISTING CONDITIONS DURING BIDDING PERIOD AS MUCH AS POSSIBLE. AFTER DEMO AND REMOVALS, FIELD VERIFY EXISTING CONDITIONS PRIOR TO PERFORMING ANY NEW W ORK, INCLUDING EQUIPMENT, PIPE, AND DUCT SIZES AND LOCATIONS, CLEARANCES, ETC.

C. ALL CUTTING AND PATCHING W ORK REQUIRED FOR THE HVAC W ORK SHALL BE INCLUDED IN THE HVAC CONTRACT. REFINISH ANY SURFACE DISTURBED UNDER THIS W ORK TO MATCH EXISTING, EXCEPT W HERE REFINISHING OF THAT SURFACE IS INCLUDED UNDER THE GENERAL CONTRACT.

D. DEMOLISHED PIPING AND DUCTW ORK SHALL BE CAPPED AT ACTIVE MAINS UNLESS NOTED OTHERW ISE. ALL OPENINGS IN EXISTING DUCTW ORK RESULTING FROM DEMOLITION W ORK SHALL BE PATCHED W ITH SHEETMETAL CLOSURE AND SEALED AIR TIGHT. INSULATE PATCH W HERE DUCT BEING PATCHED IS INSULATED.

E. EXISTING SYSTEMS SHALL REMAIN IN PLACE AND OPERATIONAL FOR AS LONG AS POSSIBLE, INCLUDING W HILE NEW EQUIPMENT IS BEING SET. COORDINATE ALL REQUIRED SHUT-DOW NS W ITH THE OW NER.

F. ALL ABANDONED EXTRANEOUS PIPING, DUCTW ORK, SUPPORTS, CONTROLS, W IRING, ETC., SHALL BE REMOVED.

G. ALL REMOVED THERMOSTATS, M IXING BOXES, GRILLES, REGISTERS AND DIFFUSERS, SHALL BE TURNED OVER TO THE OW NER. ITEMS NOT DESIRED BY THE OW NER SHALL BE REMOVED FROM THE PREMISES AND PROPERLY DISPOSED OF BY THE CONTRACTOR.

H. PATCH AND REPAIR ALL UNUSED W ALL AND FLOOR PENETRATIONS AS A RESULT OF TH IS W ORK. W ALL AND FLOOR RATINGS SHALL BE MAINTAINED, REFER TO LIFE SAFETY PLANS.

I. ALL AIR CONTROL UNITS AND OTHER EQUIPMENT ABOVE THE CEILING REQUIRING MAINTENANCE ACCESS SHALL BE A MAXIMUM OF 18" ABOVE CEILING TO ALLOW FOR ACCESS.

J. DUCT RUNOUT SIZE TO AIR TERMINAL OR AIR DEVICE SHALL BE 2" LARGER THAN SCHEDULED INLET DIAMETER OF TERMINAL UNIT OR AIR DEVICE IF RUNOUT EXCEEDS 8'-0" IN LENGTH.

K. H.C. TO COORDINATE LOCATION OF ALL DUCTW ORK AND AIR DEVICES W ITH STRUCTURAL MEMBERS, PIPE, AND DEVICES, AND THE W ORK OF OTHER TRADES. PROVIDE ADJUSTMENTS OR OFF-SETS W HERE NECESSARY.

L. OFFSET DUCTW ORK AS REQUIRED TO MAINTAIN ALL MANUFACTURERS RECOMMENDED CLEARANCES.

M. ALL W ORK SHALL BE PHASED AS DIRECTED BY THE CONSTRUCTION MANAGER/OW NER. ALSO REFER TO ARCHITECTURAL PLANS.

N. RUN-OUTS TO SUPPLY DIFFUSERS AND RETURN GRILLES AND EXHAUST GRILLES SHALL INCLUDE MANUAL DAMPERS PER DETAILS (NOT SHOW N ON PLANS FOR CLARITY). PROVIDE ADDITIONAL DAMPERS AS SHOW N ON FLOOR PLANS OR W HERE REQUIRED FOR SYSTEM BALANCING REGARDLESS OF BEING SHOW N OR NOT.

O. COORDINATE THE LOCATION OF ALL AIR DEVICES LOCATED IN THE CEILING W ITH THE ARCHITECTS REFLECTED CEILING PLAN AND ELECTRICAL LIGHTING PLAN.

P. ALL SQUARE CORNER DUCT FITTINGS SHALL BE EQUIPPED W ITH AIRFOIL TYPE TURNING VANES.

Q. DUCT RUNOUT SIZE TO CEILING DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS OTHERW ISE NOTED.

R. ALL CONTROL W IRING SHALL BE BY THE A.T.C.

S. ALL ROUGH-INS FOR NEW THERMOSTATS SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR AND W IRED PER SPECS BY CONTROLS CONTRACTOR.

PHE - SHEET LIST - MECHANICAL

Sheet Number Sheet Name

E.H001 HVAC LEGEND & GENERAL NOTES

E.H102 PARTIAL SECOND FLOOR HVAC PLAN

E.H103 PARTIAL THIRD FLOOR HVAC PLAN

E.H201 HVAC SCHEDULES

E.H202 HVAC DETAILS

1 2019.05.24 PERMIT SET

Page 6: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

2515

WOMEN'S

TLT.

146

2519

MEN'S

TLT.

149

BENCH

3 4

H

20x8 EA

12x8

EA

12x8

EA

10x6

EA

10x6

EA

1 1

2 2

22

3 4

H

24x675 CFM

K1

3

75 CFM

K112"x12"

10x6

EA

10x6

EA

12x8

EA

12x8

EA

20x8 EA

6x6 EA50 CFM

K112"x12"

100 CFM

K112"x12"

2515

STAFF

TOILET RM

2519

UNISEX

TOILET RM.

2519ACLOSET

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

1/4" = 1'-0"

2019.05.24

E.H102

PARTIAL SECOND FLOORHVAC PLAN

05/24/19

IAS

M RM

GENERAL NOTESA. COORDINATE ALL REQUIRED SHUT-DOW N'S, TIE-IN'S AND

SERVICE INTERRUPTIONS W ITH OW NER A MINIMUM OF (5) FIVE W ORKING DAYS AHEAD OF TIME.

B. REFER TO DETAILS SHEET FOR NEW DUCT TAKE-OFF AND RUNOUT TO AIR DEVICE RUNOUT REQUIREMENTS.

PLAN NOTES

SCALE: 1/4" = 1'-0"

PARTIAL SECOND FLOOR PLAN - REMOVALS1

SCALE: 1/4" = 1'-0"

PARTIAL SECOND FLOOR PLAN - NEW WORK2

1. EXISTING EXHAUST AIR DUCTW ORK TO REMAIN. ALL DUCTW ORK W ITHIN PROJECT AREA TO BE CLEANED.

2. EXISTING EXHAUST GRILLES TO BE DEMOLISHED.

3. INSTALL NEW GRILLE CENTERED ALONG FACE OF NEW SHOW ER STALL - COORDINATE W ITH ARCHITECTURAL CEILING PLAN.

1 2019.05.24 PERMIT SET

Page 7: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

140

0m

m A

RM

140

0m

m A

RM

13

00

mm

AR

M

3

-

3" S OFFI

T

2

3" S OFFI

T

3" S OFFI

T

2

3" S OFFI

T

23" SQ.

SQ.

FT

1000mm ARM

850mm ARM

1300mm ARM

140

0m

m A

RM

1400mm ARM

1300mm ARM

140

0m

m A

RM

13

00

mm

AR

M

1400mm ARM

1300mm ARM

3

N2

N1

-

3515B

HM

2

3" S OFFI

T

2

3" S OFFI

T

2

3" S OFFI

T

2

3" S OFFI

T

23" SQ.

23"

SQ.

FT

T

H

T

S

S

S

S

DP

DP

3 4

H

J

AT9-11

30/14 OV SA

14ø

SA

12x1

0 S

A

12x8 SA

DH-3

32x1

6 S

A

20/14 OV SA

12x8

SA

30/1

4 O

V S

A

18x10 RA 26x12 RA

3515-S

3515-R

8øA1

150 CFM

8x8

RA

16x1

2 R

A

12x10 EA

FC-3

10x10 SA

CATH LAB #4

3515

3517

CONTROL

RM.

20x1

6 S

A14

x14

SA

24x12 SA

24x12 SA

10x10 SA

10ø(2)A1

225 CFM

44x1

4 R

A

24x1

4 R

A

24x421300 CFM

H1

24x421300 CFM

H1

12x12450 CFM

J1

18x12500 CFM

(2)F1

18x12500 CFM

(2)F1

1

2

2

3

5

6

6

6

6

7

4

10ø(6)P1

250 CFM

12x1

0 R

A

10ø(6)P1

250 CFM

8ø(5)P2

120 CFM

6x6

EA

24x14 RA

24x1

2 S

A

3ø E

A

10

11

3 4

H

J

AT-9-03

AT9-11

AT-9-04

DH-3

3515-S

HW R

HW S

SUPPLY (1966)

RETURN (1966)

CHR

CHS

CH

S

CH

R

HW

SH

WR

CHS

CHR

HW

S

2"2"

2.5"2.5"

CHS

CHR

LPS

LPC

LPS

HW

R

HW

S

CH

R

CH

S

HW S

HW R

3"3"

CH

S

CH

R

1"1"

FC-3

2"2"

1.5"1.5"

1.5"1.5"

1.25"1.25"

1.5"1.5"

HW RHW S

2"2"

2"2"

2"2"

0.75" 1"1"

2.5"

CATH LAB #4

3515

CONTROL RM.

3517

7

12

TYP.9

1"

HW

R

LPS

LPC

HW

S

1"

0.75"0.75"

0.75"0.75"

1.5"1.5"

CH

R

CH

S

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

1/4" = 1'-0"

2019.05.24

E.H103

PARTIAL THIRD FLOORHVAC PLAN

05/24/19

IAS

M RM

SCALE: 1/4" = 1'-0"

PARTIAL THIRD FLOOR - NEW WORK - AIR DISTRIBUTION1

SCALE: 1/4" = 1'-0"

PARTIAL THIRD FLOOR - NEW WORK - HYDRONICS2

GENERAL NOTESA. COORDINATE ALL REQUIRED SHUT-DOW N'S, TIE-IN'S, SERVICE

INTERRUPTIONS, AND W ORK OUTSIDE PROJECT AREA W ITH OW NER A MINIMUM OF (5) FIVE W ORKING DAYS AHEAD OF TIME.

B. ABOVE CEILING SPACE IN THIS AREA IS VERY TIGHT - CLOSE COORDINATION AMONGST ALL TRADES IS VITAL. COORDINATION DRAW INGS OF ALL CRITICAL SPACES ARE TO BE REVIEW ED BY THE ENGINEER PRIOR TO FABRICATION AND ARE TO SHOW ALL D ISCIPLINES IN THE AREA (INCLUDING SEISMIC RESTRAINTS). REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

C. REFER TO DETAIL SHEETS FOR ADDITIONAL INFORMATION CONCERNING INSTALLATION REQUIREMENTS OF ALL AIR TERMINAL UNITS, AIR CONTROL VALVES, HOT W ATER REHEAT COILS, AND AIR DEVICES.

D. W HERE ANY DUCT OR PIPE PASSES THROUGH A RATED W ALL OR FLOOR PENETRATION THE OPENING IS TO BE PROTECTED AS INDICATED ON THE PLANS OR PER THE SPECIFICATIONS DEPENDING ON THE RATING IN QUESTION.

E. REFER TO DETAILS SHEETS FOR ADDITIONAL INFORMATION CONCERNING STEAM PIPING INSTALLATIONS AND DRIP TRAPS. PROVIDE TRAPS AT LOCATIONS INDICATED ON PLANS AND W ITHIN DETAILS, AS W ELL AS, PER THE SPECIFICATIONS, W ITHIN EACH RUN OF LPS/HPS PIPING GREATER THAN 50'-0", AND AT ALL CHANGES IN DIRECTION.

PLAN NOTES1. CONNECT NEW RETURN DUCT TO EXISTING CAPPED RETURN IN THIS

LOCATION. VERIFY EXISTING COMBINATION FIRE/SMOKE DAMPER IS INSTALLED AT FLOOR.. IF NOT ALREADY EXISTING, PROVIDE NEW FIRE/SMOKE DAMPER W ITH ACCESS DOOR IN SHAFT AND ACTUATOR MOUNTED ABOVE THE FOURTH FLOOR SLAB.

2. INSTALL NEW RETURN AIR GRILLE PER DETAIL ON SHEET E.H202. MOUNT GRILLE W ITH BOTTOM AT 8" AFF.

3. HATCHED DUCTW ORK DOW NSTREAM OF HUMIDIFIER IS TO BE CONSTRUCTED OF STAINLESS STEEL FOR THE FIRST 3' - 0" AND SHALL BE PITCHED BACK TOW ARDS HUMIDIFIER.

4. CATH LAB EQUIPMENT NOT SHOW N FOR CLARITY - REFER TO MEDICAL EQUIPMENT DRAW INGS FOR EQUIPMENT AND BOOM LAYOUTS W ITHIN SPACE. REFER TO ARCHITECTURAL CEILING PLANS FOR ADDITIONAL INSTALLATION REQUIREMENTS FOR AIR DEVICES IN PROCEDURE ROOM CEILING.

5. FLOOR SET FAN COIL UNIT SERVING ADJACENT CATH LAB EQUIPMENT ROOMS. COORDINATE LOCATION OF UNIT W ITH DOORS TO CLOSET PER MANUFACTURER'S REQUIREMENTS PRIOR TO FINAL INSTALLATION TO ENSURE SERVICEABILITY OF UNIT. ENSURE THAT RETURN AIR PATH THROUGH ENTIRETY OF CLOSET IS LEFT OPEN.

6. MOUNT SUPPLY GRILLES SERVING CATH LAB EQUIPMENT ROOM AT 9' - 0" AFF. REFER TO MIRRORED EQUIPMENT CLOSET ACROSS HALL FOR REFERENCE.

7. ROOM PRESSURE MONITOR AND ASSOCIATED THRU W ALL PRESSURE SENSOR (BASIS OF DESIGN: TSI PRESSURE RPM30). REFER TO SPECIFICATIONS AND CONTROL DIAGRAM FOR ADDITIONAL REQUIREMENTS. COORDINATE INSTALLATION LOCATION W ITH ARCHITECTURAL ELEVATIONS.

8. FAN COIL UNIT INSTALLED W ITHIN EQUIPMENT CLOSET - REFER TO DETAILS FOR PIPING REQUIREMENTS. ROUTE DRAIN TO FLOOR DRAIN W ITHIN CLOSET AND SPILL. SECURE DRAIN LINE TO W ALL/FLOOR AS REQUIRED TO AVOID TRIP HAZARD.

9. TEMPERATURE SENSOR PROVIDED BY FAN COIL MANUFACTURER MOUNTED W ITHIN CATH LAB EQUIPMENT CLOSET AT APPROXIMATELY 5'-0" AFF.

10. 3" FLEXIBLE HOSE TO TELEVAC SYSTEM W ITHIN PROCEDURE ROOM -REFER TO MEDICAL EQUIPMENT BOOM DRAW INGS FOR ADDITIONAL INFORMATION.

11. RELOCATE EXISTING DIFFUSER OUT FROM NEW W ALL AS NEEDED. COORDINATE W ITH ARCHITECTURAL CEILING PLAN.

1 2019.05.24 PERMIT SET

Page 8: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

DUCT CONSTRUCTION, SEALING, AND INSULATION

GENERAL NOTES:A. REFER TO SPECIFICATIONS FOR DUCT CONSTRUCTION: SHEET M ETAL DUCT; INTERIOR LINING; EXTERIOR INSULATION; FIBERGLASS DUCTBOARD; ETC.

NOTES:1. ROUND SHEET M ETAL RUN-OUTS TO AIR DEVICES DOW NSTREAM OF VAV BOXES SHALL BE EXTERNALLY INSULATED.2. CONCEALED ROUND RUNOUT DUCTS TO AIR DEVICES MAY BE 1" S.P. CLASS.

DUCT SYSTEM

SUPPLY DUCTW ORK UPSTREAM OF VAV BOXES FOR AH-9

+5" A 8

S.P. CON-STRUCT.

SEALCLASS

LEAKAGECLASS

S.M.A.C.N.A. CLASS.

INTERNALLYLINED

EXTERNALINSULATION

- -

NOTINSULATED

SEENOTE

DOUBLEW ALL

INSULATED

SUPPLY DUCTW ORK DOW NSTREAM OFVAV BOXES AH-9

+1" 1

-

RECT RND

16

4

8

B. DUCT CONSTRUCTION AND SEALING SHALL BE PERLATEST S.M .A.C.N.A. STANDARDS.

-

- -A - ●

RETURN DUCTW ORK -2" ● 216 8 - - -A

HVAC DESIGN DATA

GENERAL NOTES:

A. OUTDOOR DESIGN CONDITIONS:

100°F DB SUMMER

82°F W B SUMM ER

-10°F DB W INTER

NOTES:1. LISTED RH IS M AXIM UM ANTICIPATED AT LISTED DB TEM PERATURE.2. REFER TO ATC SEQUENCES FOR ACTUAL ROOM SETPOINTS.3. "FLOATING" M EANS THERE IS NO ACTIVE CONTROL.4. ROOM HAS BEEN DESIGNED TO 20 ACH BUT ASSOCIATED INFRASTRUCTURE HAS BEEN SIZED TO ALLOW FOR FUTURE INCREASE TO 25 ACH PER OW NER REQUEST.

SPACE NAM E / TYPE

INTERIOR DESIGN DATA

SEE NO TE

SUMM ER W INTER

% RH(NOTE 1) °F DB % RH

65-68

72-75 70-72

CATH LAB

CONTROL ROOM

20-60

B. DESIGN ALTITUDE: 660 FT.

TOTAL AIRCHANGES

70-72 FLOATING

PRESSURERELATIONSHIP

°F DB

20 +0.01" (OUT)

FLOATING

72-75 FLOATING

FLOATING

20-60

70-72 FLOATINGALL OTHER SPACES 72-75 FLOATING

EQUIPMENT CLOSET

- -

- -

- -

1,4

3

2

3

65-68

NOTES:1. UNIT IS A HIGH ACCURACY VARIABLE AIR VOLUME (HAVAV) AIR CONTROL VALVE. REFER TO SPEC SECTION 23 36 24.2. MINIMUM ROOM SUPPLY SHALL BE THE SCHEDULED "OCCUPIED M INIMUM " AS NOTED.

3. ROOM RETURN SHALL TRACK THE ROOM SUPPLY PLUS CFM OFFSET.4. IF NOT PROVIDED W ITH EQUIPMENT, PROVIDE AIR-TIGHT SHUT-OFF DAMPER AT EQUIPM ENT CONNECTION.

GENERAL NOTES:A. TYPES: "V.V." - VARIABLE VOLUME; "V.V.R." - VARIABLE VOLUM E REHEAT; "C.V.R." - CONSTANT VOLUM E REHEAT; "V.V.E." - VARIABLE VOLUME EXHAUST; "C.V.E." - CONSTANT VOLUM E EXHAUST.B. 0.3" M AX. S.P. DROP THRU UNIT & COIL AT MAX. CFM.C. REHEAT COIL CAPACITIES BASED ON 55° ENT. AIR & 180° ENT. W ATER, AND M AX 12 FT. HD. W .P.D.D. AUTO VALVES SHALL BE 2-W AY TYPE UNLESS NOTED OTHERW ISE.

E. REFER TO BALANCING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.F. THE AIRFLOW VALUES LISTED ARE DESIGN VALUES. THE AIR CONTROL UNITS SUPPLIER SHALL PROVIDE A "SPACE VERIFICATION TABLE" (ROOM BALANCE SHEET) THAT CONFIRM S OR REVISES THE VALUES BASED ON THEIR PRODUCT PERFORMANCE OR RECOMM ENDATIONS. THE TABLE SHALL BE SUBM ITTED W ITH SHOP DRAW INGS, AND THAT APPROVED SUBMITTAL SHALL BE THE BASIS BY W HICH THE AIR BALANCE IS PERFORM ED.

AIR CONTROL UNITS

RO

OM

OF

FS

ET

CF

M

SEISM ICRESTRAINTSAIR CONTROL UNIT

G. W HEN APPLICABLE, REFER TO SPECIFICATIONS FOR SEISMIC RESTRAINT REQUIREM ENTS.H. ROOM PRESSURE NOM ENCLATURE: "POS" - POSITIVE "NET" - NEGATIVE "NTRL" - NEUTRAL

MA

RK

RO

OM

SU

PP

LY

RO

OM

EX

HA

US

T \

RE

TU

RN

HO

OD

EX

HA

US

T

EQ

UIP

ME

NT

EX

HA

US

T

TY

PE

QU

AN

TIT

Y

DIA

ME

TE

R (

EA

CH

)

WID

TH

(E

AC

H)

HE

IGH

T (

EA

CH

)

MA

XIM

UM

MIN

IMU

M

UN

OC

CU

PIE

D S

ET

BA

CK

MIN

. C

FM

RE

HE

AT

MA

XIM

UM

CF

M

GP

M

PIP

E R

UN

OU

T S

IZE

AU

TO

VA

LV

E C

V

RE

QU

IRE

D

IMP

OR

TA

NC

E F

AC

TO

R

SEE NOTE

DUTY

REHEAT COIL

OCCUPIED CFMMINIMUM DUCT

CONNECTION INLET SIZE

RO

OM

PR

ES

SU

RE

(N

OT

E H

)

MB

H (

HO

T W

AT

ER

RE

HE

AT

)

+1000 POS 3515-S

3515-R

V.V.R.

V.V.

4000 3600 36002 14"

2 14" 3000 2600 2600

50.5 3.4 1.0" 1.6 1, 2, 41.5●

- - - - 3, 4●-

4000-

-

-

-

-

-

-

-

-

- 1.5

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

12" = 1'-0"

2019.05.24

E.H201

HVAC SCHEDULES

05/24/19

IAS

M RM

NOTES:1. SEASONAL SHUT-OFF VALVE SHALL BE LINE-SIZE-2-POSITION TYPE.2. MODULATING CONTROL VALVE FURNISHED WITH HUMIDIFIER.3. SIZES ARE APPROXIMATE, FIELD VERIFY EXACT DIMENSIONS.

GENERAL NOTES:A. STEAM SERVICE TO HUMIDIFIER IS 5.0 PSIG SATURATED STEAM.B. PROVIDE F&T TRAP(S) PER DETAILS.

C. WHEN APPLICABLE, REFER TO SPECIFICATIONS FOR SEISMIC RESTRAINT REQUIREMENTS.

STEAM HUMIDIFIERS

MA

RK

DESCRIPTION SERVICE SP

AC

E C

ON

DIT

ION

S (

DB

/RH

)

PERFORMANCE DIMENSIONS MISC.SEISMIC

RESTRAINTS BASIS OF DESIGN

SE

E N

OT

E

EN

TE

RIN

G A

IR T

EM

PE

RA

TU

RE

DB

/WB

(°F

)

LE

AV

ING

AIR

TE

MP

ER

AT

UR

E D

B/W

B (

°F)

CF

M

LB

S /

HR

MIN

. N

UM

BE

R O

F D

IST

RIB

UT

ION

TU

BE

S

MA

X.

DIS

PE

RS

ION

DIS

TA

NC

E

DU

CT

/ C

AS

ING

WID

TH

(S

EE

NO

TE

3)

DU

CT

/ C

AS

ING

HE

IGH

T (

SE

E N

OT

E 3

)

ST

EA

M S

ER

VIC

E P

IPE

SIZ

E

CO

ND

EN

SA

TE

RE

TU

RN

PIP

E S

IZE

AIR

FL

OW

PR

OO

F

HIG

H D

UC

T R

H C

UT

-OU

T

MO

DU

LA

TIN

G C

ON

TR

OL

VA

LV

E (

NO

TE

2)

SE

AS

ON

AL

SH

UT

-OF

F V

ALV

E (

NO

TE

1)

RE

QU

IRE

D

IM

PO

RT

AN

CE

FA

CT

OR

MANUFACTURER MODEL

DH-3 UNIT HUMIDIFIER CATH LAB #4 65 / 50.0 55.0 / 37.3 56.0 / 51.3 3,600 28.8 4 24" 34" 14" 1" 1" ● ● ● ● ● 1.5 DRI-STEEM XV 1,2,3

NOTES:1. PROVIDE WITH MOLDED INSULATION BLANKET.2. AIR DEVICE USED FOR RETURN AIR SYSTEM.3. AIR DEVICE USED FOR EXHAUST AIR SYSTEM.

4. BLADES TO BE PARALLEL TO SHORT DIMENSION / THE FLOOR.5. UNITS ARE TO BE PROVIDED WITH INTEGRAL INTERNAL ADJUSTMENTBAFFLE TO ALLOW FOR BALANCING THROUGH FACE OF DIFFUSER.

GENERAL NOTES:A. ALL LAY-IN AIR DEVICES SHALL FIT IN 24"X24" LAY-IN CLG SYSTEM. VERIFY GRID TYPE AND COORDINATE AIR DEVICE COMPATIBILITY.B. FINISH KEY: "W.B.E." - WHITE BAKED ENAMEL; "E.C.L." - ETCHED CLEAR LACQUER OR ANODIZED; "C.C.B.A." - CUSTOM COLOR SELECTED BY ARCHITECT.

C. SUPPLY AIR DIFFUSERS SHALL BE 4-WAY BLOW, UNLESS INDICATED OTHERWISE ON DRAWINGS.D. PROVIDE AUX. FRAMES FOR AIR DEVICES IN PLASTER, GYPSUM BOARD, TILE OR OTHER HARD SURFACES.

AIR DISTRIBUTION DEVICES

MA

RK

DESCRIPTION

MOUNTING TYPE MATERIAL FINISH

OP

PO

SE

D B

LA

DE

DA

MP

ER

SQ

-TO

-RD

NE

CK

AD

AP

TO

R BASIS OF DESIGN

SE

E N

OT

E

LA

Y-I

N

SU

RF

AC

E

DU

CT

SP

LIN

E

SN

AP

-IN

ST

EE

L

AL

UM

INU

M

ST

AIN

LE

SS

ST

EE

L

W.B

.E.

E.C

.L.

C.C

.B.A

.

MANUFACTURER MODEL

A1 STANDARD SQ. CONE CEILINGDIFFUSER RND. NECK

● ● ● TITUS OMNI-AA 1

F1 DOUBLE DEFLECTION FIXEDBLADE REGISTER

● ● ● TITUS 300FL 4

H1 FIXED BLADE REGISTER ● ● ● PRICE 730H 2, 4

J1 EGGCRATE GRILLE ● ● ● TITUS 50F 2

K1 EGGCRATE GRILLE ● ● ● TITUS 50F 3

P1 LAMINAR FLOW DIFFUSER -24"x48"

● ● ● PRICE LFD-3 5

P2 LAMINAR FLOW DIFFUSER -24"x24"

● ● ● PRICE LFD-3 5

NOTES:1. ALL AIR TERMINAL UNITS ARE TO BE PROVIDED WITH ASTAND-ALONE DDC CONTROLLER.

2. LAT = 85F.

GENERAL NOTES:A. TYPES: "V.V." - VARIABLE VOLUME; "V.V.R." - VARIABLE VOLUME REHEAT; "C.V.R." - CONSTANT VOLUME REHEAT; "V.V.E." - VARIABLE VOLUME EXHAUST; "C.V.E." - CONSTANT VOLUME EXHAUST.B. 0.50" MAX. S.P. DROP THRU UNIT & COIL AT MAX. CFM.

C. REHEAT COIL CAPACITIES BASED ON HEATING MAX. CFM, 55° ENT. AIR & 180° ENT. WATER, AND MAX. 5.0 FT. HD. W.P.D.D. AUTO VALVES SHALL BE 2-WAY TYPE UNLESS NOTED OTHERWISE.E. WHEN APPLICABLE, REFER TO SPECIFICATIONS FOR SEISMIC RESTRAINT REQUIREMENTS.

AIR TERMINAL UNITS - HOT WATER HEAT

MA

RK

TY

PE

MINIMUMINLETSIZE CFM REHEAT COIL

AU

TO

VA

LV

E C

V

SEISMICRESTRAINTS

RE

FE

R T

O N

OT

E

DIA

ME

TE

R

WID

TH

HE

IGH

T

CO

OLIN

G M

AX

IMU

M

DE

AD

BA

ND

MIN

IMU

M

RE

HE

AT

MA

XIM

UM

HE

AT

ING

MA

XIM

UM

MB

H

GP

M

PIP

E R

UN

OU

T S

IZE

RE

QU

IRE

D

IM

PO

RT

AN

CE

FA

CT

OR

AT 9-11 VVR 8" 450 120 450 340 7.3 0.5 0.75" 0.2 ● 1.5 1, 2

NOTES:1. UNIT IS TO BE PROVIDED WITH INTEGRAL DISCONNECT, UPFLOWCONFIGURATION, AND A MINIMUM OF (4) RACK SENSORS FOR TEMPERATURESAMPLING WITHIN ASSOCIATED CATH EQUIPMENT ROOM.

GENERAL NOTES:A. UNITS ARE COOLING ONLY.B. COOLING CAPACITY BASED ON 42°F ENT. WATER & 75°F DB / 61 °F WB ENT. AIR TEMP.C. WHEN APPLICABLE, REFER TO SPECIFICATIONS FOR VIBRATION ISOLATOR TYPES AND SEISMIC RESTRAINT REQUIREMENTS.

D. MOTOR: 480-3PH, UNLESS NOTED OTHERWISE.E. VERIFY / COORDINATE CABINET DIMENSIONS, MOUNTING, & RECESS REQUIREMENTS PRIOR TO ORDERING.

F. COORDINATE REQUIREMENTS FOR LINTELS IN MASONRY WALLS FOR FULL & SEMI-RECESSED UNIT WALL OPENINGS.G. BASIS OF DESIGN: VERTIV-LIEBERT CW011.

FAN COIL UNITS (COOLING ONLY)

MA

RK

DESCRIPTION MOUNTING CFM EX

TE

RN

AL

ST

AT

IC P

RE

SS

. (I

N.

W.C

.)

MO

TO

R (

HP

)

COIL PERFORMANCE

PIP

E R

UN

OU

T S

IZE

AU

TO

VA

LV

E T

YP

E

AU

TO

VA

LV

E C

V

FILTERSAPPROXIMATE CABINET

DIMENSIONS

VIB

RA

TIO

N I

SO

LA

TO

R T

YP

E

SEISMICRESTRAINTS THERMOSTAT

SE

E N

OT

E

COOLING

TH

ICK

NE

SS

/ M

ER

V

MIN

FA

CE

AR

EA

(S

Q.

FT

.)

MA

X C

LE

AN

A.P

.D.

(IN

. W

.C.)

WID

TH

DE

PT

H

HE

IGH

T

RE

CE

SS

RE

QU

IRE

D

IM

PO

RT

AN

CE

FA

CT

OR

UN

IT M

OU

NT

ED

WA

LL

MO

UN

TE

D

TO

TA

L C

AP

AC

ITY

(M

BH

)

SE

NS

IBL

E C

AP

AC

ITY

(M

BH

)

GP

M

MA

X W

.P.D

. (F

T.

HD

.)

FC-3 FAN COIL UNIT FLOOR SET / UPFLOW 2,000 0.8 1.3 39.6 36.9 11.7 8.3 1.5" 2-WAY 0.50 2" / 8 5.8 - 32" 30" 77.5" 0" INTERNAL ● 1.0 - - 1

1 2019.05.24 PERMIT SET

Page 9: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

M M

FOBN

N

5

6 7 8

4

9

10

2

2

1

3

11

NOTES1.

2.3.

4.5.

6.

7.

8.9.

10.11.

STEAM BOIL-OFF RETURN PIPING FROM HEAT EXCHANGER. INSTALL PERMANUFACTURER'S REQUIREMENTS.STAINLESS STEEL NEEDLE VALVE.SLEEVE AND FOAM AIR TIGHT ALL PIPING PENETRATIONS. PROVIDE STAINLESSSTEEL ESCUTCHEONS FOR NEAT APPEARANCE.SUPPLY AIR DUCT.DRIP LEG AND TRAP ASSEMBLY. REFER TO TYPICAL STEAM DRIP ASSEMBLYDETAIL.MOUNT STEAM SIDE STRAINER SUCH THAT STRAINER IS ON ITS SIDE IN AHORIZONTAL POSITION.LINE SIZE AUTOMATIC 2-POSITION CONTROL VALVE FOR SEASONAL OR SAFETYSHUTOFF.AUTOMATIC MODULATING CONTROL VALVE (BY TCC).STEAM DISTRIBUTORS. VERTICAL SHOWN, HORIZONTAL SIMILAR. SPACING,QUANTITIES, ETC... PER EQUIPMENT DATA.F&T STEAM TRAP, SIZED BY EQUIPMENT MANUFACTURER, 0.75" MINIMUM.FULL SIZE DIRT LEG, BUT MINIMUM 0.75" SIZE, WITH DRAIN VALVE AND HOSECONNECTION.

FT

STEAMSUPPLY MAIN

CONDENSATERETURN MAIN

GENERAL NOTESA. DETAIL IS BASED ON: DRI-STEEM ULTRA - SORB XV HUMIDIFIER DISPERSION UNIT.

ADJUST TO COMPLY WITH HUMIDIFIER MFR'S INSTALLATION INSTRUCTIONS.LPC

LPC

LPS

TYP.

.

7

8 5

1

8

2 3 6 4 9

610

TO AIR DEVICES

MAIN SUPPLY DUCT

1. CONICAL SPIN-IN BRANCH TAP FITTING, STRAIGHT SIDE. INTEGRAL INSULATION GUARD SLEEVE REQUIRED FOR TAP FITTING TO MAIN SUPPLY DUCT W ITH INTERNAL INSULATION.

2. ROUND SHEET METAL BRANCH DUCT, SAME SIZE AS AIR TERMINAL UNIT INLET SIZE UNLESS NOTED OTHERW ISE.

3. HARD DUCT CONNECTION TO AIR TERMINAL UNIT. FLEX CONNECTION NOT PERMITTED.

4. AIR TERMINAL UNIT.5. M INIMUM FOUR HANGER RODS FOR UNIT (CORNER

POINTS). ATTACH TO STRUCTURE.

6. TRANSITION W HEN REQUIRED.7. M INIMUM STRAIGHT LENGTH OF DUCT SHALL BE

TERMINAL UNIT MANUFACTURER'S REQUIRED LENGTH, BUT AT LEAST 3 TIMES UNIT INLET DIAMETER.

8. DUCT HANGER. ATTACH TO STRUCTURE.9. DUCT SHALL BE FULL SIZE OF UNIT OUTLET UNLESS

NOTED OTHERW ISE ON FLOOR PLANS.10. REHEAT COIL W HEN SPECIFIED. REFER TO COIL DETAIL.

NOTES

SUPPLY DUCT

6

8

4 3 45 4

6

9

182

10

7

CEILING CEILING DIFFUSER

1. SQUARE-TO-ROUND ADAPTER IF DIFFUSER NECK IS SQUARE. CONNECT ADAPTOR TO DIFFUSER. SEAL TO AIR DEVICE, SEAL CLASS A. INSULATE ADAPTOR AND EXPOSED BACKSIDE SURFACES OF AIR DEVICE.

2. INSULATED FLEXIBLE DUCT SAME DIAMETER AS BRANCH DUCT , 7 FT. MAXIMUM TOTAL LENGTH PER AIR DEVICE. STRETCH FLEXIBLE DUCT TO AT LEAST 90% OF FULLY EXTENDED LENGTH.

3. SPIN-IN BRANCH TAP FITTING, STRAIGHT SIDE W ITH MANUAL DAMPER. DAMPER SHAFT IN HORIZONTAL. INTEGRAL INSULATION GUARD SLEEVE REQUIRED FOR TAP FITTING TO MAIN DUCT W ITH INTERNAL INSULATION, AND EXTENDED DAMPER SHAFT AND HANDLE W ITH STAND-OFF TO ACCOMMODATE EXTERNAL INSULATION.

4. DUCT STRAP HANGER. ATTACH TO STRUCTURE.5. STRAP HANGER REQUIRED IF LENGTH OF FLEXIBLE DUCT IS

LONGER THAN 4 FT.

6. M INIMUM CENTERLINE RADIUS EQUAL TO DUCT DIAMETER.7. ROUND SHEET METAL BRANCH DUCT, SAME SIZE AS

DIFFUSER INLET UNLESS NOTED OTHERW ISE.8. FLEXIBLE DUCT ELBOW SUPPORT, INSTALLED W ITH NYLON

BANDING PER MANUFACTURER 'S INSTRUCTIONS.9. A RADIUS'D SHEET METAL ELBOW MAY BE USED IN LIEU OF

A FLEXIBLE ELBOW SUPPORT W HEN CONNECTED DIRECTLY TO AIR DEVICE.

10. CEILING T-BAR SUPPORT (FOR LAY-IN APPLICATIONS). COORDINATE AND VERIFY T-BAR TYPE FOR COMPATIBILITY W ITH DIFFUSER.

7

NOTES

6" MAX

7CEILING RETURN GRILLE

3 1 3 2 3

64

5

RETURN OR EXHAUST DUCT

1. 45 DEGREE STATIC BOOT AND MANUAL DAMPER. INTEGRAL INSULATION GUARD SLEEVE REQUIRED W HEN MAIN DUCT HAS INTERNAL INSULATION. EXTENDED DAMPER SHAFT AND HANDLE W ITH STAND-OFF REQUIRED FOR EXTERNALLY INSULATED DUCTW ORK.

2. SHEET METAL DUCT, S IZE AS NOTED ON PLANS.3. DUCT STRAP HANGER.4. STATIC BOOT SIMILAR TO EXCEPT NO DAMPER.5. SHEET METAL DUCT, FULL SIZE OF GRILLE NECK SIZE. CONNECT AND SEAL

DUCT TO GRILLE, SEAL CLASS A.6. FLEXIBLE DUCT CONNECTOR.7. CEILING T-BAR SUPPORT (FOR LAY-IN APPLICATIONS). COORDINATE AND

VERIFY T-BAR TYPE FOR COMPATIBILITY W ITH GRILLE.

1

NOTES

AIR FLOW

AIR FLOW

AIR

FL

OW

TURNING VANES

SEE FLOOR PLAN FOR SPLIT DIMENSION

MAIN SUPPLY DUCT

MANUAL VOLUME DAMPER

SUPPLY REGISTER ON BRANCH DUCT

SQUARE ELBOW SHOW N PROVIDE ROUND ELBOW W HEN SHOW N ON PLANS

AIR FLOW

AIR

FL

OW

W /4 OR 4" MIN.

MAIN SUPPLY DUCT

MANUAL VOLUME DAMPER

BRANCH DUCT

W

BRANCH DUCT TAKE-OFF

PLAN VIEW

AIR SPLIT DUCT TAKE-OFF

PLAN VIEW

THE BRANCH DUCT TAKE-OFF MAY BE USED FOR UP TO 15% OF THE MAIN DUCT CFM, AND UP TO 40% W HEN THE MAIN DUCT VELOCITY IS 1000 FPM OR LESS. THE AIR SPLIT DUCT TAKE-OFF SHALL BE USED IN ALL OTHER CASES

BRANCH DUCT

PLAN VIEW

W

W /4 OR 4" MIN.

PROVIDE MANUAL VOLUME DAMPER AT EACH BRANCH DUCT

MAIN EXHAUST OR RETURN AIR FLOW

45 DEG.

AIR

FLO

W

AIR FLOWAIR FLOW

EQ

UIP

ME

NT

AIR FLOW

TYPICAL DUCTW ORK

TRANSITION W ITH EQUIPMENT

M OUNTED IN DUCT PLAN OR

SIDE VIEW

TYPICAL DUCTW ORK

TRANSITION PLAN OR SIDE

VIEW

NOTE:

UNLESS OTHERW ISE INDICATED ON PLANS, MAXIMUM ANGLES SHOW N SHALL APPLY.

30 DEG. MAX.

AIR FLOW

15 DEG. MAX

15 DEG. MAX15 DEG. MAX.

30 DEG. MAX.

15 DEG. MAX.

CONCENTRIC TRANSITIONS UNLESSSHOW N OTHERW ISE ON PLANS

1. STEAM MAIN (30 PSIG AND BELOW ).2. F. & T. STEAM TRAP, 0.75" SIZE UNLESS NOTED

OTHERW ISE.3. COLLECTING POCKET AND DIRT LEG SAME SIZE AS MAIN.4. LENGTH FROM INVERT OF MAIN TO DRAIN PIPE, 1.5 x

MAIN DIAMETER, 8" M IN IMUM.5. CONDENSATE RETURN, FULL SIZE OF TRAP DISCHARGE,

0.75" M INIMUM.6. 0.75" DRAIN VALVE W ITH HOSE CONNECTION.7. 0.75" TEST VALVE AND DRAIN W ITH HOSE CONNECTION.

NOTES

52

1

4

3 6 7

FT

4" MIN.

.

INTERNAL DIVIDER MIDW AY IN GRILLE AND DUCT TO EQUALIZE VELOCITY ACROSS LOUVER

RETURN DUCT RISER

FLOOR

PAINT INSIDE OF DUCT BEHIND GRILLE, AND UP

DROP A MINIMUM OF 2'-0" FLAT BLACK.

8" AFF

RETURN GRILLE

1. PIPE REDUCER IF COIL CONNECTION SIZE DIFFERS FROM PIPE SIZE.2. 0.75" CONDENSATE DRAIN PIPE, CONNECT TO UNIT PAN W ITH

FLEXIBLE POLYETHYLENE TUBING.3. M INIMUM 18" LONG BRAIDED STAINLESS STEEL FLEXIBLE PIPE

CONNECTOR.4. FACTORY ASSEMBLED PIPIING PACKAGE (OPTIONAL).

A. ALL PIPING SHALL BE FULL SIZE OF MAIN RUN-OUT PIPING UNLESS NOTED OTHERW ISE.

B. REFER TO EQUIPMENT SCHEDULE FOR AUTOMATIC CONTROL VALVE SIZE.

M

1

2

D

COIL

COIL D RAIN PAN

UNIT D RAIN PAN

NOTES

GENERAL NOTES

43

3

1. LOCATE STRAINER W ITH BLOW -DOW N VALVE AN D HOSE CONNECTION AT LOW POINT OF COIL PIP ING.

2. PIPE REDUCER IF REQUIRED.3. FU LL RUN -OUT PIPESIZE.4. INSULATE FIRST 6" NEXT TO COIL.5. M INIMUM 18" LONG BR AIDED STAINLESS STEEL FLEXIBLE PIPE

CONNECTOR.6. MAXIMUM D ISTANCE FROM SUPPLY AND RETURN SHUT-OFF

VALVES TO COIL IS 48".7. FACTORY ASSEMBLED PIPING PACKAGE (OPTIONAL).8. LINE SIZE START-U P/FLUSHING BYPASS.9. OPTION 2 MAY ONLY BE USED W ITH A FACTORY PIPING PACKAGE

TH AT IS FACTORY MOU NTED RIGID LY TO THE TERMINAL UN IT.10. PIP ING SAME SIZE AS AUTO C ON TROL VALVE OR C OIL

CONNECTION, W HICH EVER IS LARGER.

A. ALL PIPING SHALL BE FULL SIZE OF MAIN RUN-OUT PIPING UNLESS NOTED OTHERW ISE.

B. REFER TO AIR TERMINAL UNIT SCHEDULE FOR AUTOMATIC CONTROL VALVE SIZE.

C. REFER TO SPECIFICATIONS FOR DEVICES NOT TO BE INSULATED. INSULATED DEVICES SHALL INCLUDE EXTENDED NECKS, SHAFTS, ETC... SO THEY ARE ACCESSIBLE ABOVE THE INSULATION.

HW R

HW S

M

COIL

6

5 23

1

7

NOTES

GENERAL NOTES

18" MIN

48" MAX

18" MIN

N.C.8

HW R

HW S

M

COIL

6

4

10

1

7

4

6" MIN

48" MAX

6" MIN

2N.C.8

4

4OPTION 1

5

5

OPTION 2 9

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

1/8" = 1'-0"

2019.05.24

E.H202

HVAC DETAILS

05/24/19

IAS

M RM

SCALE: NONE

AIR TERMINAL UNIT HARD DUCT CONNECTION1

SCALE: NONE

CEILING DIFFUSER DUCT CONNECTION2

SCALE: NONE

RETURN GRILLE DUCT CONNECTION3

SCALE: NONE

SUPPLY DUCTWORK TAKE-OFFS4

SCALE: NONE

EXHAUST OR RETURN BRANCH DUCTWORK5

SCALE: NONE

DUCTWORK TRANSITIONS6

SCALE: NONE

30 PSIG AND LOWER STEAM DRIP ASSEMBLY7SCALE: NONE

LOW AIR RETURN GRILLE8

SCALE: NONE

FAN-COIL UNIT COOLING COIL9

SCALE: NONE

AIR TERMINAL UNIT REHEAT COIL/DUCT HEATING COIL10

1 2019.05.24 PERMIT SET

SCALE: 1/8" = 1'-0"

DUCT MOUNTED HUMIDIFIER11

Page 10: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

BENCH

OS

OSOS

L

L

BENCH

GF

GF

ELECTRICAL SYMBOLS

EXISTING OUTLET OR DEVICE TO REMAIN . MAINTAIN EXISTING C IRCUITING.

DASH SYMBOL INDICATES PARTICULAR OUTLET OR DEVICE TO BE REMOVED AND CIRCUITRY MADE CONTINUOUS W HERE REQUIRED.

ELECTRICAL CONNECTION.

20A-125V HOSPITAL GRADE DUPLEX RECEPTACLE, NEMA 5-20R (18" MH UNLESS NOTED OTHERW ISE).

20A-125V HOSPITAL GRADE SINGLE RECEPTACLE, NEMA 5-20R (18" MH UNLESS NOTED OTHERW ISE).

HOSPITAL GRADE SPECIAL PURPOSE RECEPTACLE. REFER TO NOTE ON PLAN.

20A-125V HOSPITAL GRADE DOUBLE DUPLEX RECEPTACLE. NEMA 5-20R , (18" MH UNLESS NOTED OTHERW ISE) TW O GANG ASSEMBLY.

20A-125V HOSPITAL GRADE DUPLEX RECEPTACLE, NEMA 5-20R W ITH BOTTOM OUTLET CONTROLLED BY W ALL SW ITCH. (18" MH UNLESS NOTED OTHERW ISE).

20A-125V HOSPITAL GRADE DUPLEX RECEPTACLE, NEMA 5-20R , W ITH GROUND FAULT CIRCUIT INTERRUPTER (18" MH UNLESS NOTED OTHERW ISE).20A-125V W EATHERPROOF HOSPITAL GRADE DUPLEX RECEPTACLE, NEMA 5-20R (HORIZONTAL 18" MH UNLESS NOTED OTHERW ISE) W ITH TAYMAC #10310 STANDARD COVER, VERTICAL MOUNT.

20A-125V W EATHERPROOF HOSPITAL GRADE DUPLEX RECEPTACLE, NEMA 5-20R W ITH GROUND FAULT CIRCUIT INTERRUPTER (18" MH UNLESS NOTED OTHERW ISE), W ITH TAYMAC #20310 STANDARD COVER, VERTICAL MOUNT.

POKE-THROUGH W ITH POW ER AND DATA.

JUNCTION BOX. SQUARE DEVICE INDICATES A CONNECTION TO CRITICAL POW ER.

MULTI-OUTLET RECEPTACLES ASSEMBLY, NEMA 5-15R (SINGLE OUTLETS ON 18" CENTERS) (46" MH UNLESS NOTED OTHERW ISE).

SPECIFICATION GRADE SINGLE POLE SW ITCH (46" MH UNLESS NOTED OTHERW ISE).

SPECIFICATION GRADE MULTI-W AY W ALL SW ITCH, # INDICATES NUMBER OF W AYS (46" MH UNLESS NOTED OTHERW ISE).

SPECIFICATION GRADE KEY OPERATED W ALL SW ITCH (46" MH UNLESS NOTED OTHERW ISE).

0-10V DC SPECIFICATION GRADE LIGHTING DIMMER SW ITCH (46" MH UNLESS NOTED OTHERW ISE).

DISCONNECT SW ITCH.

MOTOR STARTER.

COMBINATION MOTOR STARTER AND DISCONNECT SW ITCH.

ELECTRIC MOTOR.

ELECTRICAL PANEL OR SW ITCHBOARD PER DRAW INGS.

LINE VOLTAGE THERMOSTAT.

POW ER POLE.

2 OUTPUT ROOM CONTROLLER EQUAL TO HUBBELL #NXRC-2RD-UNV. ASSOCIATED DIMMER SW ITCHES SHALL BE EQUAL TO HUBBELL #NXSW -ORLO-XX AND ASSOCIATED LOW -VOLTAGE SW ITCHES SHALL BE EQUAL TO HUBBELL #NXSW -1-XX.

CEILING MOUNTED OCCUPANCY SENSOR.

PUSHBUTTON (46" MH UNLESS NOTED OTHERW ISE) EDW ARDS 852 (120 VOLT).

GF

W P

W P/GF

J

#

K

D

PP

OS

T

20A-125V HOSPITAL GRADE DUPLEX RECEPTACLE, NEMA 5-20R (46" MH UNLESS NOTED OTHERW ISE).

ELAPSED TIME INDICATOR CLOCK (90" MH UNLESS NOTED OTHERW ISE) W ITH RESET SW ITCH (46" MH UNLESS NOTED OTHERW ISE).

SPECIFICATION GRADE LOW -VOLTAGE MOMENTARY W ALL SW ITCH (46" MH UNLESS NOTED OTHERW ISE).L

ABBREVIATIONS

AAP - AREA ALARM PANEL - MEDICAL GASATS - AUTOMATIC TRANSFER SW ITCH

DIV - D IVISION

EC - ELECTRICAL CONTRACTOR (DIVISION 26)ELEC - ELECTRICALELEV - ELEVATION OR ELEVATOREM - EMERGENCYEQUIP - EQUIPMENTE - EXISTING TO REMAINE/R - EXISTING TO BE RELOCATED

GC - GENERAL CONTRACTORGF - GROUND FAULT CIRCUIT INTERRUPTERGFCI - GROUND FAULT CIRCUIT INTERRUPTER

HC - HVAC CONTRACTOR (DIVISION 23)HP - HORSE POW ERHVAC - HEATING, VENTILATING, AND AIR CONDITIONING

MH - MOUNTING HEIGHT TO CENTER LINE OF ITEMMTD - MOUNTED

PC - PLUMBING CONTRACTOR (D IVISION 22)

REF - REFRIGERATOR

S - SURFACE MOUNTEDSPEC - SPECIFICATIONS

TV - TELEVISION/MONITORTYP - TYPICAL

VFD - VARIABLE FREQUENCY DRIVE

W P - W EATHERPROOF

ZVC - ZONE VALVE CABINET

1

E2

B

E2DETAIL: B = DETAIL DESIGNATION

E2 = SHEET W HERE DETAIL IS LOCATED

SECTION: 1 = SECTION DESIGNATION E2 = SHEET W HERE SECTION IS LOCATED

PLAN NOTE. APPLIES ONLY TO THE SHEET W HICH IT IS SHOW N.

DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.

GENERAL FLOOR PLAN NOTES

EACH ARROW HEAD REPRESENTS ONE COMPLETE CIRCUIT; "X" DENOTES PANEL NAME; NUMBER(S) DENOTES CIRCUIT(S).

X - 1,2

3

3

LUMINAIRE SYMBOLS

LIGHTING FIXTURE. CAPITAL LETTER DENOTES FIXTURE TYPE, LOW ER CASE LETTER DENOTES SW ITCHING ARRANGEMENT.

LIGHTING FIXTURE ON CRITICAL CIRCUIT.

EXIT LIGHTIN G FIXTURE, ARROW S AS INDICATED.

Aa

3

3

20A-125V HOSPITAL GRADE DUPLEX RECEPTACLE, NEMA 5-20R W ITH 2 INTEGRAL USB CHARGERS (18" MH UNLESS NOTED OTHERW ISE).

NOTE:• ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT

TO MODIFICATIONS ON OTHER DRAWINGS.• ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT

NECESSARILY BE USED ON THIS PROJECT.

LIGHTING FIXTURE ON LIFE SAFETY AND NIGHT LIGHT.

SQUARE DEVICE INDICATES A CON NECTION TO CRITIC AL POW ER. SPECIFICATION IS SAM E AS RESPEC TIVE ROU ND DEVIC E.

J

1

EM ER GENCY POW ER OFF (EPO) SW ITCH. SW ITCH SHALL HAVE CLEAR PROTECTIVE COVER.

RC2

SECURITY SYMBOLS WITH ELECTRICAL REQUIREMENTS

HDHANDICAP DOOR OPERATOR MOTOR ASSEMBLY. PROVIDE ROUGH-IN. PROVIDE ALL CONTROL W IRING AND ROUGH-IN FOR PUSH PLATE / CARD READER PER MANUFACTURER'S REQUIREMENTS.

FINISHED FLOOR

SIDE VIEW

.1'-0"

0'-6

"

.1'-3"

1 CUSTOM STAINLESS STEEL DIVIDED FLOOR PEDESTAL BOX PROVIDED BY E.C. LOCATED AT FOOT OF OR TABLE. REFER TO SIEMENS DRAW INGS FOR REQUIRED CLEARANCES.

2 ROUNDED CORNERS (TYPICAL).

3 20A 120V DOUBLE DUPLEX W HITE RECEPTACLE AND IVORY PLATE. PROVIDE BACKBOX. TYPICAL BOTH SIDES.

4 1.5" GROMMETED OPENING FOR LOW VOLTAGE VIDEO CABLING.

5 DIVIDER PLATE BETW EEN LOW VOLTAGE AND LINE VOLTAGE SECTIONS.

6 STAINLESS STEEL REMOVABLE FACEPLATE.

7 REFER TO FACEPLATE ELEVATION THIS SHEET FOR LOW VOLTAGE INFORMATION.

8 PROVIDE CONDUIT BUSHINGS. BOND TO ENCLOSURE.

9 PROVIDE CONCRETE ANCHORS.

10 CORED OPENING W ITH FIRE CAULK.

11 W ATERPROOF STAINLESS STEEL CURB. INSET W IDTH EQUAL TO FLOOR FINISH TH ICKNESS. ANCHOR TO CONCRETE FLOOR.

12 FLASHING/COVE BASE BY FLOORING CONTRACTOR (TYPICAL).

13 PHILIPS VIDEO BOXES, VB10 AND VB11 (9.5"X9.5"X2.1875")

14 PROVIDE SINGLE-GANG FACEPLATE FOR LOW -VOLTAG E DATA CABLING.

DETAIL NOTES

2 2

OPEN BOTTOM

9

FRONT SECTION

9

POW ERCONDUIT

8

PHILIPS CONDUITS 55,56,57,58&59 (5-1.5" DIA

CONDUITS)

.

.

FACEPLATE ELEVATION

0'-8"

0'-5

1/2

"6

5

7

1'-10"

2

1

36

10

.

. 0'-3

"111212

.

22

2

7

7(LOW VOLTAGE FACEPLATE LOCATED ON BACKOF PEDESTAL)

(ACCESS COVERLOCATED ON FRONT

OF PEDESTAL)

1

CONCRETE FLOOR

FINISHED FLOOR

2

CONCRETE FLOOR

9

POW ERCONDUIT

8

5

12

2

.1'-8"

10

10 9

13 13

PHILIPS CONDUITS 55,56,57,58&59 (5-1.5" DIA

CONDUITS)

CONNECTOR END

446

.0'-11"

0'-4

-3/4

'

14

(BACK)

(FRONT)

7(ACCESS COVER

LOCATED ON FRONTOF PEDESTAL)

7(LOW VOLTAGE FACEPLATE LOCATED ON BACKOF PEDESTAL)

TOP VIEW

55

13 13

10 (TYP)

SECTIONSECTION

3 4

H

11

3 4

H

E/R

F6

F6F6S

2515

STAFFTOILET RM

2519

UNISEXTOILET RM.

2519ACLOSET

2

2

2

W 2W 2

3 4

H

2515

STAFFTOILET RM

2519

UNISEXTOILET RM.

2519ACLOSET3

E/R

E/R

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

As indicated

2019.05.24

E.E001

ELECTRICAL LEGEND,SCHEDULES AND SHEET

INDEX

05/24/19

KMU

LLC

Notes:

Amps: 35 A

Load: 4.14 kVA

12 Space -- -- 0.00 kVA

11 Space -- -- 0.00 kVA

10 Space -- -- 0.00 kVA

9 SPARE 20 A 2 0.00 kVA

8 REC REFRIGERATOR 20 A 2 0.90 kVA

7 REC CRASH CART 20 A 2 0.54 kVA

6 REC CYRO 20 A 2 0.36 kVA

5 REC 20 A 2 0.36 kVA

4 ANESTHESIA BOOM CIRCUIT 4 "OMNICELL" 20 A 2 0.54 kVA

3 ANESTHESIA BOOM CIRCUIT 3 20 A 2 0.36 kVA

2 EQUIPMENT BOOM CIRCUITS 3 & 4 20 A 2 0.54 kVA

1 EQUIPMENT BOOM CIRCUITS 1 & 2 20 A 2 0.54 kVA

CKT Circuit Description Trip Poles Load

General Notes:

Enclosure: Type 1

Mounting: Recessed Mains Rating: 7.5 kVA

Supply From: E184-CB Mains Type: 45A MB

Location: CONTROL RM. 3517 A.I.C. Rating: 10,000

ISOLATION PANEL: E188-CB

Notes:

Amps: 35 A

Load: 4.14 kVA

12 Space -- -- 0.00 kVA

11 Space -- -- 0.00 kVA

10 Space -- -- 0.00 kVA

9 Space -- -- 0.00 kVA

8 SPARE 20 A 2 0.00 kVA

7 REC BLANKET WARMER 20 A 2 0.90 kVA

6 REC OMNICELL 20 A 2 0.36 kVA

5 REC 20 A 2 0.18 kVA

4 ANESTHESIA BOOM CIRCUITS 1 & 2 20 A 2 0.54 kVA

3 EQUIPMENT BOOM CIRCUITS 8 & 9 20 A 2 0.54 kVA

2 EQUIPMENT BOOM CIRCUITS 6 & 7 20 A 2 0.54 kVA

1 MOTOR & BRAKE 20 A 2 1.08 kVA

CKT Circuit Description Trip Poles Load

General Notes:

Enclosure: Type 1

Mounting: Recessed Mains Rating: 7.5 kVA

Supply From: E184-CB Mains Type: 45A MB

Location: CONTROL RM. 3517 A.I.C. Rating: 10,000

ISOLATION PANEL: E189-CB

Notes:

Amps: 9 A

Load: 1.08 kVA

12 Space -- -- 0.00 kVA

11 Space -- -- 0.00 kVA

10 Space -- -- 0.00 kVA

9 Space -- -- 0.00 kVA

8 SPARE 20 A 2 0.00 kVA

7 SPARE 20 A 2 0.00 kVA

6 SPARE 20 A 2 0.00 kVA

5 SPARE 20 A 2 0.00 kVA

4 SPARE 20 A 2 0.00 kVA

3 REC 20 A 2 0.36 kVA

2 REC 20 A 2 0.18 kVA

1 REC 20 A 2 0.54 kVA

CKT Circuit Description Trip Poles Load

General Notes:

Enclosure: Type 1

Mounting: Recessed Mains Rating: 7.5 kVA

Supply From: N80 Mains Type: 45A MB

Location: CONTROL RM. 3517 A.I.C. Rating: 10,000

ISOLATION PANEL: N193

NOTES:1.

LUMINAIRES

MARK

LAMPS

VO

LT

AG

E

LO

AD

(V

A)

MANUFACTURER CATALOG NO. DESCRIPTION

MOUNTING

SE

E N

OT

E

TY

PE

CA

TA

LO

G N

O.

COLOR

S-SURFACER-RECESSEDSM-STEM MTDWM-WALL MTDC-CHAIN MTD

UC-UNDER CABCS-CEIL SURFACE

B22 LED INCLUDED 3500K 120 30 COLUMBIA LTRE22-35MLG-RFA-EDU-G1 2'X2' LED RECESSED BASKET TYPE LUMINAIRE R

F6 LED INCLUDED 3500K 120 16 PRESCOLITE LF6SL-6LFSL-15L-35K-8-WT 6" LED RECESSED CAN LIGHT R

F6A LED INCLUDED 3500K 120 13 PRESCOLITE LC6SL-DM-6LCSL-10L-35K-8-WT 6" LED RECESSED CAN LIGHT R

F6S LED INCLUDED 3500K 120 13 PRESCOLITE LC6SL-6LFSL-11L-35K-8-SNCT 6" LED RECESSED SHOWER LIGHT R

OR6 LED INCLUDED 3500K 120 33 PRESCOLITE LF6MLDM1-6LFML30L35K9SSIP65WT 6" LED RECESSED CAN LIGHT R

OR14 LED INCLUDED 3500K 120 113 KURTZON ML-OR-5-1X4-2/LEDH-935-UNV-XXX-1/CIR-ASY 1'X4' LED RECESSED LENSED TROFFER R

W2 LED INCLUDED 3500K 120 22 WAC LIGHTING WS-6724-30 24" VANITY LIGHT R

PHE - SHEET LIST - ELECTRICAL

Sheet Number Sheet Name

E.E001 ELECTRICAL LEGEND, SCHEDULES AND SHEET INDEX

E.E002 ELECTRICAL SINGLE LINE DIAGRAM

E.E103 PARTIAL THIRD FLOOR - ELECTRICAL DEMOLITION PLAN

E.E203 PARTIAL THIRD FLOOR - NEW WORK LIGHTING PLAN

E.E303 PARTIAL THIRD FLOOR - NEW WORK POWER PLAN

E.E401 CATH LAB 4 - PHILIPS DRAWINGS

E.E402 CATH LAB 4 - PHILIPS DRAWINGS

E.E403 CATH LAB 4 - PHILIPS DRAWINGS

5.58 kVA 5.96 kVA (17 A)

TOTAL CONNECTED ESTIMATED DEMAND

Notes: 1. PREVIOUSLY LABELED B2.

Total Load: 3.06 kVA 1.08 kVA 1.44 kVA

41 Space -- -- 0.0 kVA 0.0 kVA -- -- Space 42

39 Space -- -- 0.0 kVA 0.0 kVA -- -- Space 40

37 Space -- -- 0.0 kVA 0.0 kVA -- -- Space 38

35 Space -- -- 0.0 kVA 0.0 kVA -- -- Space 36

33 Space -- -- 0.0 kVA 0.0 kVA -- -- Space 34

31 Space -- -- 0.0 kVA 0.0 kVA -- -- Space 32

29 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 30

27 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 28

25 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 26

23 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 24

21 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 22

19 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 20

17 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 18

15 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 16

13 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 14

11 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 12

9 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 10

7 REC 20 A 1 0.7 kVA 0.7 kVA 1 20 A REC 8

5 REC 20 A 1 0.7 kVA 0.7 kVA 1 20 A REC 6

3 REC 20 A 1 0.7 kVA 0.4 kVA 1 20 A LTG 4

1 REC CONTROL RM.... 20 A 1 0.5 kVA 1.1 kVA 1 20 A LTG Room 3515, 3517 2

CKT Circuit Description Trip PolesA B C

Poles Trip Circuit Description CKT

Voltage: 120/208 Wye-3PH-4W Mains Rating: 200 ASupply From: DP5 Enclosure: Type 1 Mains Type: MLO

Location: EX. PASSAGE 3402 Mounting: Surface A.I.C. Rating: 10,000

Panel: E87B-CB

5.16 kVA 5.38 kVA (15 A)

TOTAL CONNECTED ESTIMATED DEMAND

Notes:

Total Load: 1.92 kVA 1.44 kVA 1.80 kVA

41 Space -- -- 0.0 kVA 0.0 kVA -- -- Space 42

39 Space -- -- 0.0 kVA 0.0 kVA -- -- Space 40

37 Space -- -- 0.0 kVA 0.0 kVA -- -- Space 38

35 Space -- -- 0.0 kVA 0.0 kVA -- -- Space 36

33 Space -- -- 0.0 kVA 0.0 kVA -- -- Space 34

31 Space -- -- 0.0 kVA 0.0 kVA -- -- Space 32

29 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 30

27 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 28

25 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 26

23 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 24

21 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 22

19 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 20

17 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 18

15 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 16

13 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 14

11 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 12

9 REC 20 A 1 0.7 kVA 0.0 kVA 1 20 A Spare 10

7 REC 20 A 1 0.2 kVA 0.2 kVA -- -- -- 8

5 REC 20 A 1 0.9 kVA 0.9 kVA 2 50 A N193 6

3 REC 20 A 1 0.2 kVA 0.5 kVA 1 20 A REC 4

1 REC Room 3517 20 A 1 0.7 kVA 0.8 kVA 1 20 A LTG CATH LAB #4 3515 2

CKT Circuit Description Trip PolesA B C

Poles Trip Circuit Description CKT

Voltage: 120/208 Wye-3PH-4W Mains Rating: 200 ASupply From: DP-6 Enclosure: Type 1 Mains Type: MLO

Location: EX. PASSAGE 3402 Mounting: Surface A.I.C. Rating: 10,000

Panel: N80A

NOTES:1.

MOTORS, STARTERS, DISCONNECTS & CONTROLS

MARK

MOTOR STARTER DISCONNECT MEANS CONTROL FEEDER

SE

E N

OT

E

NAMEPLATE

CHARACTERISTICS LOCATION

NE

MA

SIZ

E

TYPE LOCATION

FU

RN

ISH

ED

BY

TYPE LOCATION

FU

RN

ISH

ED

BY

IN

TE

RL

OC

K W

ITH

MO

TO

R N

O.

BY

E.C

.

MA

NU

AL

AT

ST

AR

TE

R

IN

TE

GR

AL W

ITH

EQ

UIP

ME

NT

FU

RN

ISH

ED

BY

SE

E N

OT

E

NU

MB

ER

OF

CO

ND

UC

TO

RS

WIR

E S

IZE

GR

OU

ND

SIZ

E

CO

ND

UIT

SIZ

E

HO

RS

EP

OW

ER

(H

P)

LO

AD

(kV

A)

48

0V

-1P

H

48

0V

-3P

H

RO

OM

NU

MB

ER

ROOM NAME MA

NU

AL

MA

GN

ET

IC

BU

ILT

-IN

MO

TO

R O

/L

2-S

PE

ED

VF

D

SE

E N

OT

E

NE

AR

MO

TO

R

MO

TO

R C

ON

T C

EN

TE

R

EQ

UIP

CO

NT

PA

NE

L

RO

OM

NU

MB

ER

SE

E N

OT

E

DIS

C S

WIT

CH

MA

NU

AL

ST

AR

TE

R

RE

CE

PT

AC

LE

FE

ED

ER

SW

OR

BR

EA

KE

R

NE

MA

TY

PE

DIS

C S

IZE

FU

SE

SIZ

E

NE

AR

MO

TO

R

MO

TO

R C

ON

T C

EN

TE

R

EQ

UIP

CO

NT

PA

NE

L

PA

NE

LB

OA

RD

SE

E N

OT

E

FC-3 FAN COIL 3 1 1.5 ● ● ● HC ● ● HC HC 3 12 12 0.75

SCALE: NONE

"MGP" FLOOR PEDISTAL1

SCALE: 1/8" = 1'-0"

2ND FLR - ELEC DEMOLITION PLAN3

SCALE: 1/8" = 1'-0"

2ND FLR - NEW WORK LIGHTING PLAN4 SCALE: 1/8" = 1'-0"

2ND FLR - NEW WORK POWER PLAN5

1 REMOVE ALL LUMINAIRES, RECEPTACLES,FIRE ALARM DEVICES, PUBLIC ADDRESSDEVICES, NURSE CALL DEVICES,DATA/COMMUNICATION DEVICES, ETC.UNLESS OTHERWISE NOTED. MAINTAINEXISTING LIGHTING AND RECEPTACLECIRCUITS FOR NEW WORK.

2 UTILIZE EXISTING LIGHTING CIRCUITMAINTAINED DURING DEMOLITION PHASE.

3 UTILIZE EXISTING RECEPTACLE CIRCUITMAINTAINED DURING DEMOLITION PHASE.

1 2019.05.24 PERMIT SET

Page 11: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

NE

NONE

E87A-CB

200A/3P (200A)

N193

E188-CB

E85-CB

E189-CB E87B-CB

CATHLAB #4

UPS

MA

80/3PCB

N80A

150A(NEW)

150A STCB2

SINGLE-LINE DIAGRAM

N

100A/3PMANUALTRANS.

PDU1A PDU1B

480D208Y/120V75KVA

SONETPDU1-LS

3

HV3

LIFE SAFETY

B3

A2

C3A3

1"C

ELEV. ELEV.

ELEV. ELEV.

ELEV. ELEV.

EM43

SECTION #1

EM51ELEC.

SHOP

EM1

EM53EM53A

EM41

SP

AC

E F

OR

200A

SW

ITC

H

SECTION #2

1200AMAIN

CATSCANLEIBERT

AC

SP

AR

E10

0S

PA

RE

100

SP

AR

E10

0

200

200

SP

AR

E20

0

200

EM55

EM42

EM50

EM5

EM3 EM4 EM2

'66 BLDG.

SECTION #3

EM6

SP

AR

E20

0S

PA

RE

200

SP

AR

E20

0S

PA

RE

200

SP

AC

E20

0

SP

AC

E20

0

SECTION #4 SECTION #1

OLD MATERNITY A.C.

BOILER

SECTION #2

200

SP

AR

E10

0

SP

AR

E10

0

100

SP

AR

E10

0

SP

AR

E10

0

ROOM

OLD AH #1E

ME

R.

NO

RM

.

O.U. BLDG.

OLD

SP

AC

E20

0

P3

EMX1

SECTION #1 SECTION #2

SP

AR

E60

SP

AR

E20

0

SP

AR

E20

0

SP

AR

E40

0P2

CATHLAB

SP

AR

E60

P4

TO WESTPARKING

LOT LIGHTS

SP

AR

E30

P5

SP

AR

E

CHILLERRM. 21

SP

AR

E20

0

800

SP

AR

E20

0

200A

MED AIRPUMP

PACKAGE #2

100A

MED VACPUMP

PACKAGE #2

800 800 1600

SECT. #1 SECTION #2

TO O.U. BLDG.

200A

SP

AC

E

200A

SP

AC

E

EM9

SHORT

EM9A

STAY

1� 200ATELE.

FRAMEROOM

NUCLEARMEDICINE

ELEC.SHOPCAGE

PLUMB.SHOPHALL

SECTION #1 SECTION #2 SECTION #3 SECTION #4

1600

200

HALLNEARRM. 5

200

HG

200

AAG(AG)

E

SP

AC

E

200

AA12300

2-10

0AS

PA

CE

200

GG12300

EAST

HH12300

WEST

200

BG

200

CG

200

DG

400

GG

2-10

0AS

PA

CE

2-10

0AS

PA

CE

SP

AR

E10

0

SP

AR

E10

0

SP

AR

E20

0

200

200

NG

200

2-10

0AS

PA

CE

2-10

0AS

PA

CE

SP

AR

E10

0S

PA

RE

100

200

NL1

200

NL2

SITE

200

PG

LIGHTING

LPN-150

NUCLEARMEDICINE

COMM. RM.PHARMACY

T16

200

R1

2-10

0AS

PA

CE

SECTION #4 SECTION #3 SECTION #2 SECTION #1

2-10

0AS

PA

CE

SP

AR

E10

0S

PA

RE

100

"N62"(BB)

200

TRANSFERFOR PHONE

SWITCH

200

MG

200

FG

F1

200

200

SP

AC

E

SP

AR

E20

0

B1

200

C1

200

D1

E1

200

200

KG

400

'66 BLDG.NUCLEAR

200

200

TG

SP

AR

E20

0

400

SP

AR

E20

0

200

200

EG

200

SG

400

JG

TO LS SECT. 2

TO TS14

TO SC1

SP

AR

E

SP

AC

E

SP

AC

E

SP

AC

E

SP

AC

E

SP

AC

E

1600 800 800SPACESPACE

J1J1A

SHORTSTAY

TVROOM

SHORTSTAY

CATHLAB

3600'66

EM44B

CATHLAB

TO TS13

SP

AR

E

SP

AR

E

SP

AR

E

SP

AR

E

MORGUE

EM44A

RADIOLOGYCLOSET

QI

RAD.

RAD.CLOSET

BLDG.

K12300

D24600

LAB KITCH.

KITCH.STEAMROOM

LOBBY

ELEV. #7THERAPY

PHYS.

MED.

NUC.

HALLRADIOLOGYTHERAPY

PHYS.

HIMS COMM. ROOM

D1ADOCTOR'S

READING RM.

PHARM.

HALLNEARPBX

PHONESWITCH

REGULATOR

GGELEV. OLD LAB KIT.

MAILROOMWALL

#3 & 4LOBBY

KIT.KIT.

MANHOLE #__

MCC1

EM

ER

.

MCC6

RADIOLOGY

QI

TO DP18SECT. 3

SHEET E-5

3600

A15600

TO ELEV. #10

SEE SHEET E-6

B16600

EM13

'66 BLDG.

EM13A

'66 BLDG.EM13B

LAB

HALLOLDMAIL

ROOM

RAD.HALL

2300

CHEM.LAB

QIRAD.

RAD.CLOSET

MORGUE

PENTHOUSEPANEL

ELEV. #8

SHEET E-4

SHEET E-4

SHEET E-4

SHEET E-4

#3 #4

#5 #6

#7 #8

TA

G 1

2-93

RE

MO

VE

D

CHILLER 3RM. 3

SPACESPACE

TO PSC-2

N177

N178

CB X-RAY CATHLAB

ANGIO

AB

DP6

LABELED C2

3/60

2/60

E133EB

B506

E148CB

B521E146CB

1342

E131CB

2432

E103CB

2407

E102CB

4542E75CB

4545E75ACB

2430E100CB

1518

E132CB

2316

E109CB

EM422316

E109CB

E128CB

2435E101CB

E127CB

B415

E147CB

1616

E129CB

3617

E78CB

4645

E71CB

6600

E68CB

6642N66

B522E145EB

3403

CTFEEDER

B503E139EB

2407E104EB

7601

3618N76

3419N83

5642N69

B400

N14

3CB

N14

2

B424E140

1725E124

N136B524

N117

1342N110

2316N105

2314N107

N106

N111N112

N113 N115N116

CAPPEDOFF IN

BOILER RM.

B521

N138N137

1616N121

2317N125

1335N120 1313

N114

2606N88

N89 N90

N91A

N91

N92

4653N123B

N70N72 N74 N73

3618N77

N79

2311N123A

N119

N1231631 N122

1728

J1

N62B408

N961500 N95

1500

N1181725

2332N94

2407N93

2314N108

2437N18L

E59CB E182CB

E61CB E67CB

B522

E63CB E64CB

3621E44ALS

2432E44BLS

1342E43LS

B522E60LS

TO SHEETE-4E60LS

CAGE

OLD HIMS

DICTATION

SP

AR

E

TRANSFORMER

NEED'S #

MCC1APENTHOUSE

N-P

PANEL C2VASCULAR LAB

HALL 3618

6500

7603 7603

TO TS-23

60/3

(40)

100/

3

100/

3

EM44CLS

60A/2P

(40A)

60A/2P

(50A)

WP

60/3

30A/2P

(25A)

480V

10KVA 60A/3P PMS240/120V

EXISTING PULL BOX

NOTE: DARK LINE WEIGHT REPRESENTS NEW WORK.

"MTS2-LS"

100

"MTS1-LS"

UPSBYPASS

PBXUPS

EM43MORGUE

TO "LS"

E128ACB(LAB)

N96A N95A

EM6A FGA

SHAFTDAMPERS

ELEV.MACHINERM

ELEV.COND.UNIT

A/C

20A/2P

(20A)

T31000 KVA12,470V TO480V - 3PH - 3W

T21500 KVA12,470V TO280Y/120V - 3PH - 4W

T12000KVA12,470V TO480V - 3PH - 3W

T11KVA

V TOV - 3PH - 3W

SB (NE W)

E44-LS(NEW)

60/260/260/3

400/3

(400A)

400/3

(250A)

400/3

(300A)

480Δ TO480/277V500 KVA 6.69%

TRANSFORMERTAP

125/3PE195-CB

TS-1

200/3(200A)

EMX1

EMP1

E82EB

CATHLABUPS

N192

200/3(200A)

MA

EPLABUPS

MA

80/3PCB

80/3PCB

125/3P STCB2

125/3P STCB2

E84-CB (EM8)

N80

E

SB

E87-CB

E233-EB

60/3P

E186-CB

E187-CB

E184-CB

E185-CB

N191

E

1525

1500

42

XX

X

5

HV2

6 2 1

XX

X

U1

UG

U3

C2

C1

HV1

XX

X

TO PSC-2 TO PSC-2

1725

2315

1400

1427

1518

1725

1725

2435

2435

1616

2529

2517

2517

4653

4542

4504

4542

3419

DP3 ()1600A - 208Y/120V-3PH-4W

DP2 ()1600A - 208Y/120V-3PH-4W

DP1 ()1000A - 480V-3PH-4W

DP16 ()A - 480V-3PH-3W

DP4 ()800A - 480V-3PH-3W

DP5 ()800A - 208Y/120V-3PH-4W

DP15 ('71 BLDG. BASEMENT,

OFFICE NEAR ROOM 5)A - 480V-3PH-3W

DP6 (RM 3403)800A - 208Y/120V-3PH-4W

US2 ()3000A - 208Y/120V-3PH-4W

US3 ()1600A - 480V-3PH-3W

US1 ()2000A - 480V-3PH-3W

SEVENTH

SIXTH SIXTH

FIFTH FIFTH

FOURTH FOURTH

THIRD THIRD

SECOND SECOND

FIRST FIRST

BSMNT BSMNT

ROOF

SCALE:

1

2

3

3

4

4

4

1

12

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

3/32" = 1'-0"

2019.05.24

E.E002

ELECTRICAL SINGLE LINEDIAGRAM

05/24/19

KMU

LLC

NOTES

1 UTILIZE FEED THRU LUGS IN EXISTING PANEL.

2 UTILIZE SPARE 50A/2P BREAKERS.

FEEDER INFORMATION1 3-#2, 1-#2 GROUND IN 1.25" CONDUIT.

2 3-#1/0, 1-#1/0 GRD. IN 1.5" CONDUIT.

3 2-#6, 1-#10 GRD. IN 1" CONDUIT.

4 4-#3/0, 1-#2 GRD. IN 2" CONDUIT.

1 2019.05.24 PERMIT SET

Page 12: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

46"

46"

46"

46"

46"

46"

CO

DD

DD

DD

DD

LOS

OS

L

L

L

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

D

D

J

J

J

J

J

TV

46"

46"

J

J

CY

RO

JJ

DD

DDD D

DD

46"

TV

OC

RF

J

J

J

3

3

4

D

OS

OSL

D

OS

LOS

J

GF

OS

D

GF

GF

OC

CC

BWGF

J

J

GF

46"

46"

46"

46"

OS

OS

OS

J

HDHD

HD

HD

HD HD HD HD

HDHD

OS

OS

OS

OS

J

46"

46"

BW

5

DN

3

4

RTN.

1 2

3 4

5

6

7 9 10 12

E

G

H

J

8

F

C14

C14

C14

C14

C14

C14

C14

C14

E/R

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

3/16" = 1'-0"

2019.05.24

E.E103

PARTIAL THIRD FLOOR -ELECTRICAL DEMOLITION

PLAN

05/24/19

KMU

LLC

0 2 4 8 12 16

SCALE: 3/16" = 1'-0"

PARTIAL THIRD FLOOR - ELECTRICAL DEMOLITION PLAN1

NOTES

1 2019.05.24 PERMIT SET

Page 13: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

DD

DD

DD

DD

LOS

OS

L

L

L

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

D

D

JJ

DD

DDD D

DD

D

OS

OSL

D

OS

LOS

J

OS

D

OS

OS

OS

J

OS

OS

OS

OS

1000mm ARM

850mm ARM

1300mm ARM

1400

mm

ARM

1400mm ARM

1300mm A RM

1400

mm

ARM

1300

mm

AR

M

1400mm ARM

1300mm A RM

3

N2

N1

5

DN

3

4

RTN.

2

3" SOFFI

T

2

3" SOFFI

T

2

3" SOFFI

T

2

3" SOFFI

T

23" SQ.

23"

SQ.

D

D

DD

DD

J

J 33

33

1 2

3 4

5

6

7

9 10 12

E

G

H

J

8

F

OR14OR14

OR

14O

R14

OR

14O

R14

OR

14O

R14

OR14OR14OR14

B22 B22 B22

F6A F6A F6A

OR6OR6

OR6OR6

N80A - 2

b b b

b

b

bb

b

b

b

b

E87B-CB - 2E87B-CB - 2

E87B-CB - 2E87B-CB - 2

bc

N80A - 2 N80A - 2 N80A - 2

b

bE87B-CB - 2N80A - 2N80A - 2

E87

B-C

B -

2E

87B

-CB

-2

N80

A -

2E

87B

-CB

-2

E87

B-C

B -

2E

87B

-CB

-2

N80A - 2E87B-CB - 2

cc

cc

e e e

dd d

ed

3

14

2

1

4

E87B-CB - 4

E87B-CB - 4

OR

14

b

E87

B-C

B -

2

OR

14

b

N80

A -

2

OR

14b

N80

A -

2

RC2

RC2 b

5

eF6A

E87B-CB - 2 E87B-CB - 2 E87B-CB - 2

CONTROL RM.

3517

CATH LAB #4

3515OR14

b

N80A - 2

E189-CB E188-CB N193

E/R

E/R

E/R

E/R

E/R

E/R

E/R

E/R

x

x

x

x

y

y

y

y

x

x

y

y

6

6 6

6

E44

-LS

E87

-CB

E87

B-C

B

N80

A

N80

E19

5-C

B

DP-6

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

3/16" = 1'-0"

2019.05.24

E.E203

PARTIAL THIRD FLOOR -NEW W ORK LIGHTING

PLAN

05/24/19

KMU

LLC

0 2 4 8 12 16

SCALE: 3/16" = 1'-0"

PARTIAL THIRD FLOOR - NEW WORK LIGHTING PLAN1

NOTES

1 PROVIDE CONNECTION TO STRYKER "SK" ENCLOSURE LOCATEDABOVE ACCESSIBLE CEILING.

2 APPROXIMATE LOCATION OF STRYKER WALL CONTROLLER "L2".PROVIDE 4" SQ. BACKBOX AND 1" CONDUIT WITH PULL STRING TO"SK" ENCLOSURE.

3 FOOT SWITCH SHALL CONTROL OR6 LUMINAIRES. PROVIDERELAY AND CONTROL WIRING PER PHILIP'S LIGHTING DETAIL.REFER TO PHILIP'S SHEET ED3.

4 STRYKER "SK" ENCLOSURE FURNISHED BY STRYKER, INSTALLEDBY EC. PROVIDE 1" CONDUIT AND LOW-VOLTAGE WIRING TOEACH LIGHT BOOM PER STRYKER'S CONDUIT SCHEDULE ANDPRE-INSTALL NOTES SCHEDULE.

5 PROVIDE INVERTER TRANSFER SYSTEM EQUAL TO EVENLITE#PW25-LC-V1. INVERTER SHALL BE FOR OR6 LUMINAIRES IN THISSPACE. MOUNT INVERTER UP HIGH ON WALL AND PROVIDELABEL.

6 IT SHALL BE ACCEPTABLE TO SURFACE MOUNT ALLBOXES/CONDUIT IN THIS SPACE. CONNECT NEW LIGHTING TOLOCAL CORRIDOR NORMAL POWER LIGHTING CIRCUIT.

1 2019.05.24 PERMIT SET

Page 14: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

46"

46"

46"

46"

46"

46"

CO

J

J

J

J

J

TV

46"

46"

J

J

CY

RO

46"

TV

OC

RF

J

J

J

GF

GF

GF

OC

CC

BWGF

J

J

GF

46"

46"

46"

46"

HDHD

HD

HD

HD HD HD HD

HDHD

J

46"

46"

BW

1000mm ARM

850mm ARM

1300mm ARM

1400

mm

ARM

1400mm ARM

1300mm A RM

1400

mm

ARM

1300

mm

AR

M

1400mm ARM

1300mm A RM

3

N2

N1

5

DN

3

4

RTN.

2

3" SOFFI

T

2

3" SOFFI

T

2

3" SOFFI

T

2

3" SOFFI

T

23" SQ.

23"

SQ.J

J

J

J

J

J

J

BW

OC

RF

GF

CC

CY

RO

J46

"

46"

46"

TV46

"

1 2

3 4

5

6

7

9 10 12

E

G

H

J

8

F

E188-CBE189-CB N193

E189-CB - 4

E189-CB - 1

3

4

4

E188-CB - 3,4

E84-CB - 32,34

E189-CB - 2,3

E188-CB - 1,2

7

EQUIPMENT "C" BOOM

ANESTHESIA "B" BOOM

N19

3 -

3

E18

9-C

B -

5

N19

3 -

3

N19

3 -

1

N193 - 2

E189-CB - 7

N193 - 1

E188-CB - 5

E188-CB - 5

N193 - 1

E189-CB - 6

E188-CB - 8

E18

8-C

B -

6

E188-CB - 7

N80A - 7

13

1 2 5

8

10

9

E84-CB - 26

E18

8-C

B -

7

CONTROL RM.

3517

CATH LAB #4

3515

E195-CB - 1,3,56CB2

CB

11

14

EMP1 - 43,45,47FC-3 FC-2

E87B-CB - 1

E87

B-C

B -

3

E87

B-C

B -

3

E87

B-C

B -

5

E87

B-C

B -

5

E87

B-C

B -

7

E87

B-C

B -

7

E87B-CB - 6

E87B-CB - 8

N80A - 1

N80

A -

1

N80

A -

1

N80

A -

5

N80

A -

5

N80

A -

5

N80

A -

4N

80A

-4

N80A - 9

N80A - 9

E87B-CB - 6

E87B-CB - 8

E87

-CB

E87

B-C

B

N80

A

N80

E44

-LS

E19

5-C

B

E84-CB

N80

A -

3

15 15

15 15

DP-6

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

LARRY L.

OHAT

ST

EOF

I O

COTTERMANE-60417

IEF

O

RP

ASS

NOI GNEL

SIGER DERETE

N

RE

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

3/16" = 1'-0"

2019.05.24

E.E303

PARTIAL THIRD FLOOR -NEW W ORK POW ER PLAN

05/24/19

KMU

LLC

0 2 4 8 12 16

SCALE: 3/16" = 1'-0"

PARTIAL THIRD FLOOR - NEW WORK POWER PLAN1

NOTES

1 BRANCH CIRCUIT WIRING ASSOCIATED WITH ISOLATED POWERPANELS SHALL BE TYPE XHHW. EC SHALL MAKE CIRCUITLENGTHS AS SHORT AS POSSIBLE. LIM POWER BRANCHCIRCUITS DO NOT HAVE TO PARALLEL BUILDING LINES.

2 EC SHALL BE RESPONSIBLE FOR PROVIDING ALL PHILIPS ANDSTRYKER REQUIRED SYSTEM POWER, GROUNDING, LIGHTING,RACEWAY, CONDUIT, CABLE TRAY, WALL DUCT, ETC. AS DEFINEDPER VENDOR'S DRAWINGS. CONTACT KELLY LOCKHART WITHPHILIPS AND ZACH SHARY WITH STRYKER.

3 EC SHALL PROVIDE CIRCUIT FOR LASER RECEPTACLE WITHINBOOM.

4 PROVIDE CONNECTION TO BOOM MOTOR AND BRAKE.

5 EC SHALL PROVIDE ALL CONDUIT PER SCHEDULE ON STRYKERDRAWINGS.

6 UPS INPUT AND OUTPUT CIRCUIT BREAKERS. REFER TO SINGLELINE DIAGRAM.

7 UTILIZE SPARE 30A/2P GFCI BREAKER.

8 PROVIDE CONNECTION TO COMBINATION DIGITAL CLOCK /ELAPSED TIMER.

9 PROVIDE 120V CONNECTION TO STRYKER TELEVAC SYSTEM.REFER TO STRYKER PRE-INSTALL NOTES SCHEDULE FOR SCOPEOF WORK. UTILIZE SPARE 20A/1P BREAKER IN EXISTING PANEL.

10 ENGRAVE RECEPTACLE TO READ "MAINTENANCE RECEPTACLE".

11 SIX (6) SPARE 1" CONDUITS AND SIX (6) SPARE 0.75" CONDUITSWERE STUBBED AT THIS LOCATION FROM ELECTRICAL ROOMUNDER PREVIOUS PHASE. UTILIZE THESE CONDUITS FOR NEWFEEDERS/CIRCUITS BACK TO ELECTRICAL ROOM.

13 PROVIDE REMOTE LINE ISOLATION MONITORS FOR EACH PANEL(TOTAL OF THREE) STACKED ON WALL. PG LIFELINK MARK V#DRA-VS.

14 CONNECT TO CIRCUIT SERVING EXISTING FC-2.

15 IT SHALL BE ACCEPTABLE TO SURFACE MOUNT ALLBOXES/CONDUIT IN THIS SPACE.

1 2019.05.24 PERMIT SET

Page 15: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

ENTHIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C1 AND SHOULD NOT BE SEPARATED.

Pro

ject

Det

ails

Phi

lips

Con

tact

sP

roje

ct

Dra

win

g N

umbe

r

N-M

ID19

0046

CD

ate

Dra

wn:

5/9

/201

9

Quo

te:

Ord

er:

Azu

rion

7 C

20

1.22.19

1-1Z

YV

Y3F

Rev

. 3

6600

4295

61.0

1000

0

THE

INF

OR

MA

TIO

N IN

TH

IS P

AC

KA

GE

IS P

RO

VID

ED

AS

A C

US

TOM

ER

CO

NV

EN

IEN

CE

, AN

D IS

NO

T TO

BE

CO

NS

TRU

ED

AS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

OR

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

.

Phi

lips

assu

mes

no

liabi

lity

nor o

ffers

any

war

rant

y fo

r the

fitn

ess

or a

dequ

acy

of th

e pr

emis

es o

r th

e ut

ilitie

s av

aila

ble

at th

e pr

emis

es in

whi

ch th

e eq

uipm

ent i

s to

be

inst

alle

d, u

sed,

or

stor

ed.

KM

CN

Gra

ndvi

ew H

ospi

tal

Day

ton,

OH

Roo

m: C

ath

Lab

4

© K

onin

klijk

e P

hilip

s E

lect

roni

cs N

.V. 2

019.

All

right

s re

serv

ed. R

epro

duct

ion

in w

hole

or

in p

art i

s pr

ohib

ited

with

out p

rior w

ritte

n co

nsen

t of t

he c

opyr

ight

hol

der.

Dra

wn

By:

Lynd

e D

. Pep

per

Pro

ject

Man

ager

:

Con

tact

Num

ber:

Em

ail:

Kel

ly L

ockh

art

(330

) 696

-580

9

kelly

.lock

hart

@ph

ilips

.com

Electrical Requirement Notes for Systems with Mains 40E Cabinet

Electrical power distribution at the facility shall comply with:

Utilization voltages per ANSI C84.1 - 2006 range A.

Voltage to be supplied is 3 phase, Wye or symmetric Delta 3-line +PE.

Phase conductors to be sized for instantaneous voltage drop per NEC 517.73 and Philips recommendations.

All Philips equipment is grounded via the equipment insulated ground wire. Metal raceway bonding shall be usedas a secondary ground fault return path only for the supply mains to the equipment. The raceway system ground

and isolated equipment ground shall be bonded together via the ERB terminal jumpers.

The Philips system has a private ground domain per clause 250.96B of the NEC. The raceway from the X-raybreaker (CB) to the Mains 40E Cabinet shall be supplemented by an internal insulated equipment grounding

conductor installed in accordance with clause 250.146(D) of the NEC. The Azurion equipment ground domain andthe branch circuit ground domain are bonded together in the ERB via a ground bonding jumper.

ANSI / NFPA 70 -National Electrical CodeArticle 250 - Grounding

Article 517 -Healthcare FacilitiesANSI / NFPA 99 -Healthcare FacilitiesNEMA standard XR9: 1984-R2000 - Power Supply Guideline for X-ray Machines

Power Quality Guidelines

1. Power supplied to medical imaging equipment must be separate from power feeds to air conditioning,

elevators, outdoor lighting, and other frequently switched or motorized loads. Such loads can cause waveformdistortion and voltage fluctuations that can hinder high quality imaging.

2. Equipment that utilizes the facility power system to transmit control signals (especially clock systems) mayinterfere with medical imaging equipment, thus requiring special filtering.

3. The following devices provide a high impedance, nonlinear voltage source, which may affect image quality:Static UPS systems, Series filters, Power conditioners, and Voltage regulators.Do not install such devices in the supply mains branch circuit of the Azurion system without consulting Philipsinstallation or service personnel.

4. Line impedance is the combined resistance and inductive reactance of the electrical system and includes theimpedance of the power source, the facility distribution system, and all phase conductors between the source andthe imaging equipment. Philips publishes recommended conductor sizes based on equipment power

requirements, acceptable voltage drops, and assumptions about the facility source impedance. The minimumconductor size is based on the total line impedance and NEC requirements. Unless impedance calculations areperformed by an electrical engineer, the recommended values must be used.

(16.0)

Emergency Power

Philips does not require equipment to be on emergency power. If the customer deems it necessary for the

equipment to be supplied with emergency power, the following specifications must be applied:

The Mains 40E cabinet feeding an Azurion system will have an absolute peak current of <=380A @480V.Maximum momentary current <=80 Arms per phase when averaged over a 5-second window. Note that during

acquisition, the current harmonics (including sub- and inter-harmonics) up to 1 kHz can be substantial. Accountfor : 30% for the mains frequency +/- the frame speed, up to 20% for the 5th harmonics, up to 10% for the 7thharmonics.

The transfer switch must be double actuator type with a minimum time delay of 400 milliseconds in both directions

(utility to emergency - emergency to utility). This time is required to allow filters to dissipate their stored energybefore a different mains voltage is applied.

To reduce the emergency power generator load demand, Philips equipment can be put into a lower power mode

of operation by the connection of a potential free closure, normally open contact, from the transfer switch. Thispotential free, normally open contact, has to be rated for 24VDC/100mA. For Philips cardio/vascular Azurion

equipment, the two wires from this contact have to be routed to the equipment area and connected to the SystemCoordinator cabinet (MA).

Maximum differential mode induced disturbance voltage on these wires shall be a <3V peak at al frequencies.

Maximum common mode current on these wires shall be less than 3 micro-amp at frequencies between30-1000MHz to meet EMC regulations.

For systems delivered to site before Jan 2016 or with SIB (system interface box) 4522163320978. When thisinterface is used a Sub-D capacitive filter adapter with 5.6nF between pins and chassis shall be placed on X14 ofthe SIB input in the MA-cabinet (e.g. Amphenol FCE17B25AD290).

(19.0)

General Electrical Information

1. GeneralThe customer shall be solely responsible, at its expense, for preparation of the site, including any required electrical alterations. The site preparation shall be in accordance

with this plan and specifications, the architectural/construction drawings and in compliance with all safety and electrical codes, the customer shall be solely responsible forobtaining all electrical permits from jurisdictional authority.

2. Materials and Labor

The customer shall be solely responsible, at its expense, to provide and install all electrical ducts, boxes, raceways (conduits, wireways, auxiliary gutters etc.), fittings, bushing,etc., As separately specified herein.

3. Electrical Ducts and BoxesElectrical ducts and boxes shall be accessible and have removable covers. Floor ducts and boxes shall have watertight covers. Ducts shall be divided into as many as four

separate channels by metal dividers, separately specified herein, to separate wiring and/or cables into groups as follows: Group A: Branch circuit equipment supply mainspower wires together with the branch circuit isolated equipment bonding wire. Group B: Equipment Secondary Circuit AC supply and associated isolated ground cable/wire

harnesses. Group C: Equipment signal wires and cable harnesses plus equipment low-voltage DC supply cable/wire harnesses. Group D: X-Ray high-voltage cables, the useof 90 deg. ells is not acceptable. On ceiling duct and wall duct use 45 deg. bends at all corners. All intersecting points in duct to have cross over tunnels supplied and installed

by contractor to maintain separation of cables based on 725.136 for low voltage signaling cables and conductors and 517.80 for communications and signaling cables in healthcare applications. Secondary circuits of transformer powered communications and signaling systems are not required to be enclosed in raceways unless otherwise specifiedby Chapter 7 or Chapter 8. All wire harnesses of the Azurion system are required to be run in a raceway (wireway) dedicated to Azurion wire harnesses. No foreign wiring shall

be run in the same wireway together with the Azurion wire harnesses. Separation between Group A and other groups is mandatory along the full run of group A wires.Separation between groups B, C, and D is recommended for the first 3 meters behind the equipment cabinets and for the locations where wire-harness over-length issuspended.

4. Raceways (Conduit)Raceway (Conduit) point - to - point runs shall be as direct as possible. Empty conduit runs used for cables may require pull boxes located along the run. Consult with Philips.A pull wire or cord shall be installed in each conduit run. Best practice to name the physical conduit. All conduits which enter duct prior to their termination point must maintainseparation from other cables via use of dividers, cross over tunnels, or conduit supplied and installed by contractor from entrance into duct to exit from duct. Do not use flex

conduit unless approved by Philips Service.

5. Conductors

All conductors, separately specified, shall be 90°C stranded copper, rung out and marked.

6. Disconnecting MeansA disconnecting means shall be provided as separately specified.

7. Warning Lights and Door Switches"X-ray on" warning lights and x-ray termination door switches should be provided at all entrances to x-ray rooms as required by code.

8. Dimmer SwitchesX-ray room lights should be provided with dimmer switches. (19.0)

Electrical Notes

1. The contractor will supply & install all breakers, shunt trip and incoming power to the breakers. The exact location of the breakers and shunt trips will be determined bythe architect or contractor.

2. The contractor shall supply & install all pull boxes, raceway runs, stainless steel covers, etc. Conduit/raceways must be free from burrs and sharp edges over its entirelength. A Greenlee pull string/measuring tape (part no. 435, or equivalent) must be provided with raceway runs to validate runs are within length restrictions.

3. All pre - terminated, cut to length cables, will be supplied and installed by Philips. All cables and conductors to the equipment supply mains branch circuit breaker shall besupplied and installed by the contractor, subject to local arrangements.

4. Provide and install 50mm diameter chase nipples between adjacent wall boxes.

5. Electrical raceway ducts shall be installed with removable covers. The raceway should be accessible for the entire length. In case of non - accessible floors, walls andceilings, an adequate number of access hatches should be supplied to enable installation of cabling. Approved raceways may be substituted. All raceways will be designed

in a manner that will not allow cables to fall out of the raceway when the covers are removed. In most cases, this will require above - ceiling raceway to be installed with thecovers removable from the top. Raceway systems as illustrated on this drawing are based upon length of furnished cables. Any changes in routing of raceway systems could

exceed maximum allowable length of furnished cables. Conduits or raceways installed above ceilings must be kept as near as practicable to finished ceilings and still permitaccessibility.

6. Raceway sizes shall be verified by the architect, electrical engineer or contractor, in accordance with local or National Electrical Code, whichever govern.

7. Convenience outlets are not shown on the plans. Their number and location are to be specified by the customer/architect.

8. Electrical contractor shall install grounding and bonding conductors at raceway openings within wall boxes as required by national and local electrical codes. Groundbond wires and lugs shall be installed in such a way to prevent the inadvertent contact with the installed Philips equipment to maintain Philips isolated ground scheme andmaintain patient safety.

9. Install an insulated stranded ground wire per feeder/conductor size from the Main Disconnect (CB) to the ERB (recommended size 4 AWG) and from the ERB to theMains 40E Cabinet (recommended size 4 AWG).

10. Philips equipment must be electrically isolated from conduits, raceways, ducts, seismic anchoring, floor anchoring, etc.

(18.0)

ELTHIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C1 AND SHOULD NOT BE SEPARATED.

Pro

ject

Det

ails

Phi

lips

Con

tact

sP

roje

ct

Dra

win

g N

umbe

r

N-M

ID19

0046

CD

ate

Dra

wn:

5/9

/201

9

Quo

te:

Ord

er:

Azu

rion

7 C

20

1.22.19

1-1Z

YV

Y3F

Rev

. 3

6600

4295

61.0

1000

0

THE

INF

OR

MA

TIO

N IN

TH

IS P

AC

KA

GE

IS P

RO

VID

ED

AS

A C

US

TOM

ER

CO

NV

EN

IEN

CE

, AN

D IS

NO

T TO

BE

CO

NS

TRU

ED

AS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

OR

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

.

Phi

lips

assu

mes

no

liabi

lity

nor o

ffers

any

war

rant

y fo

r the

fitn

ess

or a

dequ

acy

of th

e pr

emis

es o

r th

e ut

ilitie

s av

aila

ble

at th

e pr

emis

es in

whi

ch th

e eq

uipm

ent i

s to

be

inst

alle

d, u

sed,

or

stor

ed.

KM

CN

Gra

ndvi

ew H

ospi

tal

Day

ton,

OH

Roo

m: C

ath

Lab

4

© K

onin

klijk

e P

hilip

s E

lect

roni

cs N

.V. 2

019.

All

right

s re

serv

ed. R

epro

duct

ion

in w

hole

or

in p

art i

s pr

ohib

ited

with

out p

rior w

ritte

n co

nsen

t of t

he c

opyr

ight

hol

der.

Dra

wn

By:

Lynd

e D

. Pep

per

Pro

ject

Man

ager

:

Con

tact

Num

ber:

Em

ail:

Kel

ly L

ockh

art

(330

) 696

-580

9

kelly

.lock

hart

@ph

ilips

.com

Item Number

Description

Detail Sheet

Optional

Future

Existing

Furnished by Philips and installed by contractor

Installed by customer/contractor

Furnished by customer/contractor and installed by customer/contractor

G

D

C

B

Furnished and installed by PhilipsA

F

E

Electrical Legend

See E1 - E3 sheets for conduit and raceway requirements.

Item Number

Description

Detail Sheet

Optional

Future

Existing

Furnished by Philips and installed by contractor

Installed by customer/contractor

Furnished by customer/contractor and installed by customer/contractor

G

D

C

B

Furnished and installed by PhilipsA

F

E

Electrical Legend

D19 1

4 " (490mm) W x 67" (1705mm) H x 4" (105mm including rubber isolation strips) D flanged-edge terminal backbox, surface mounted 82" (2085mm) A.F.F. to top of box.

ED3ME

MRMA

BGrommet opening on "WR3". Approximate location shown is recommended and may be changed - verify

relocation with local Philips Service.CY

WM

B18" (460mm) W x 18" (460mm) L x 6" (155mm) D ceiling box, flush mounted with removable screw-type coverplate. Provide one 3" (80mm) diameter knockout.

SP

B

18" (460mm) W x 18" (460mm) L x 6" (155mm) D ceiling box, flush mounted with removable screw-type cover

plate. Provide a 2 12 " (65mm) round cutout (Two 2 1

2 " (65mm) round cutouts are required for systems with twomonitor carriages - verify with local Philips Service). VB8 and VB9 to be mounted on rear side of FlexVisionmonitor.

VB8TV

VB9

B10" (255mm) W x 3 1

2 " (90mm) D wall raceway, surface mounted with removable screw-type cover plate. "WR3" isat finished floor. "WR3" may need to be cut at the location of the "CY" connection box.

ED3WR3

B

Auxiliary Box - 6" (155mm) W x 6" (155mm) H x 4" (105mm) D wall box, flush mounted 70" (1780mm) A.F.F. to

the bottom of the box with removable screw-type cover plate. Height and location shown are recommended andmay be changed - verify height and relocation with local Philips Service.

ATY

BWarning Light - Provide a surface or flush mounted light fixture above door to indicate when X-ray is on, if

required by local code or physicist of record. (Not shown on plan)ED3WL

B

Door Switch - 120V/5A switch limited to open when door is open. Mount in upper corner on strike side of mainentry door(s) (Cooper no. 1665 or equivalent), if required by local code or physicist of record. See Sheet "ED3"

diagram for connection details. (Not shown on plan)ED3DS

N1B

RJ45 type Ethernet 10/100/1000 Mbit network connector with access to customer's network. Locate within 10'

(3050mm) of network card. Network fiber optic and Ethernet cabling, connectors, wall boxes, patch panels, etc.are the responsibility of the purchaser. Philips assumes no responsibility for procurement, installation, ormaintenance of these components.

N2BRJ45 type Ethernet 10/100/1000 Mbit network connector. Access to customer's network via their remote accessserver is needed for Remote Service Network (RSN) connectivity.

N1

SB 120V/20A dedicated duplex outlet for service in the equipment room. (Not shown on plan)

VB1VB2

MB B120V/20A dedicated duplex outlet for each of the Video Connection Boxes. Verify electrical requirements forcustomer provided equipment.

B Local building steel (i.e. structural steel, ground rod). (Not shown on plan)GE

BEqui-Potential Reference Bar mounted in a 12" (305mm) W x 12" (305mm) H x 4" (105mm) D pull box with hinged

cover, surface mounted to the bottom of "WR2" when possible.ED2ERB

VB3VB4

B10" (255mm) W x 3 1

2 " (90mm) D wall raceway, surface mounted with removable screw-type cover plate. "WR1" isat 5" (130mm) A.F.F. to bottom of raceway. "WR2" is at 82" (2085mm) A.F.F. to bottom of raceway.

ED3WR1

WR2

B

Shunt Trip (emergency off) - Large mushroom-head button on remote control station with contacts to operate

feature of "CB" (if required by local code or owner, and mandatory for VA and D.O.D installations). If UPS isutilized, EPO switch will run 2 sets of communication wires to input breaker to UPS and to UPS itself (Not shownon plan)

ED4ST

B

480V, 3 phase, Type D 80 A circuit breaker with long-time delay (e.g. Square D HDL36080 or equivalent). Runpower from breaker to "MA", leaving an 8' (2440mm) tail at "MA". See Sheet "ED1" for power quality

requirements. Location per local code or owner requirements. (Not shown on plan)

ED1ED4

CB

B 120V/20A dedicated duplex outlet for Pedestal Injector.

B 120V/20A duplex outlets (qty: 2) for "TV2" and Wall Connection Boxes.

B

10" (255mm) W x 10" (255mm) L x 6" (155mm) D floor box, under the floor with a 5" (130mm) core drill up to the

underside of AD7 universal floor plate. Contractor to provide protection around core drill hole so that there are nosharp edges for protection of cables. Consult with local Philips Service.

MSA

VB5VB6

D UPS - 80 kVA. ED4UPS

D Battery Cabinet for UPS. ED4BC

BRemote Status Alarm Panel (wall mounted in the control area). Exact height to be determined. Location shown isrecommended and may be changed - verify relocation with customer/contractor.

ED4ED6

RSAP

3B 120VAC with 1Amp power draw RSAP (Remote Status Alarm Panel)

B UPS input breaker. 150 Amp, 3-pole circuit breaker with shunt trip. (Not shown on plan). ED4CB2

B

Med Gas Pedestal. Verify exact size with customer/contractor and location with Local Philips Service. "VB10 andVB11" to be mounted on MGP. Location shown is requested by PM and may be changed - verify relocation with

local Philips Service. LCD on cart must remain within 25' (7.62m) of "VB10 and VB11".

VB10MGP

VB11

VB7

MA

MR

WR1WR2

MB

ME

2'-0

"2'

-0"

2'-0

"

ERB

2'-0

"1'

-2"

WMWR3

MG

P VB

10V

B11

2'-4

"

6'-3"

115 16"

4'-1

1"

6'-3"

MS

A

SP

77 8

"

VB

9TV

VB

8

VB3VB4VB6 CY

N2

N1

VB1VB2

3

RS

AP

BC

UPS

3'-6

"3'

-21 4

"

1'-5" 1'-6" 1'-6" 1'-4" 3'-0" 4'-3"3'-6"

VB5

ATY

5'-9

"20

'-8"

�A

D7

Tabl

e Fl

oor

Pla

te

Clea / Table

�13'-3"

14'-3

"

VB7

1'-4"

E1THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C1 AND SHOULD NOT BE SEPARATED.

Pro

ject

Det

ails

Phi

lips

Con

tact

sP

roje

ct

Dra

win

g N

umbe

r

N-M

ID19

0046

CD

ate

Dra

wn:

5/9

/201

9

Quo

te:

Ord

er:

Azu

rion

7 C

20

1.22.19

1-1Z

YV

Y3F

Rev

. 3

6600

4295

61.0

1000

0

THE

INF

OR

MA

TIO

N IN

TH

IS P

AC

KA

GE

IS P

RO

VID

ED

AS

A C

US

TOM

ER

CO

NV

EN

IEN

CE

, AN

D IS

NO

T TO

BE

CO

NS

TRU

ED

AS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

OR

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

.

Phi

lips

assu

mes

no

liabi

lity

nor o

ffers

any

war

rant

y fo

r the

fitn

ess

or a

dequ

acy

of th

e pr

emis

es o

r th

e ut

ilitie

s av

aila

ble

at th

e pr

emis

es in

whi

ch th

e eq

uipm

ent i

s to

be

inst

alle

d, u

sed,

or

stor

ed.

KM

CN

Gra

ndvi

ew H

ospi

tal

Day

ton,

OH

Roo

m: C

ath

Lab

4

© K

onin

klijk

e P

hilip

s E

lect

roni

cs N

.V. 2

019.

All

right

s re

serv

ed. R

epro

duct

ion

in w

hole

or

in p

art i

s pr

ohib

ited

with

out p

rior w

ritte

n co

nsen

t of t

he c

opyr

ight

hol

der.

Dra

wn

By:

Lynd

e D

. Pep

per

Pro

ject

Man

ager

:

Con

tact

Num

ber:

Em

ail:

Kel

ly L

ockh

art

(330

) 696

-580

9

kelly

.lock

hart

@ph

ilips

.com

Electrical Layout3/16" = 1'-0"

Required Unistrut Height: 9' - 6 316 ", + 3

8 " / -0 (2900mm, +10mm / -0)Unistrut height measured from finished floor to bottom of Unistrut.

Refer to Electrical Legend - Sheet ELand Raceway/Conduit - Sheet E2-E3

Equipment Closet(Site Specific)

Control Room(Site Specific)

WR3

N1

N2

WR3

2'-6

"

10"

8'-0

"

Finished FloorWM

VB5

Finished Floor

9'-6

"

6'-1

0"

1'-3

"10

"

WR1

WR2

ERB

MBMRMEMA

2'-0"2'-0"2'-0" 2'-0"

Min

. 8'-0

" (2

400m

m)

VB4VB3VB2VB1

1'-6"1'-6"1'-4"3'-0"4'-3"

11'-21116

"

1'-2"

VB6

1'-5" 3'-6"

CY

VB7

1'-4"

21'-05

16"

E2THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C1 AND SHOULD NOT BE SEPARATED.

Pro

ject

Det

ails

Phi

lips

Con

tact

sP

roje

ct

Dra

win

g N

umbe

r

N-M

ID19

0046

CD

ate

Dra

wn:

5/9

/201

9

Quo

te:

Ord

er:

Azu

rion

7 C

20

1.22.19

1-1Z

YV

Y3F

Rev

. 3

6600

4295

61.0

1000

0

THE

INF

OR

MA

TIO

N IN

TH

IS P

AC

KA

GE

IS P

RO

VID

ED

AS

A C

US

TOM

ER

CO

NV

EN

IEN

CE

, AN

D IS

NO

T TO

BE

CO

NS

TRU

ED

AS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

OR

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

.

Phi

lips

assu

mes

no

liabi

lity

nor o

ffers

any

war

rant

y fo

r the

fitn

ess

or a

dequ

acy

of th

e pr

emis

es o

r th

e ut

ilitie

s av

aila

ble

at th

e pr

emis

es in

whi

ch th

e eq

uipm

ent i

s to

be

inst

alle

d, u

sed,

or

stor

ed.

KM

CN

Gra

ndvi

ew H

ospi

tal

Day

ton,

OH

Roo

m: C

ath

Lab

4

© K

onin

klijk

e P

hilip

s E

lect

roni

cs N

.V. 2

019.

All

right

s re

serv

ed. R

epro

duct

ion

in w

hole

or

in p

art i

s pr

ohib

ited

with

out p

rior w

ritte

n co

nsen

t of t

he c

opyr

ight

hol

der.

Dra

wn

By:

Lynd

e D

. Pep

per

Pro

ject

Man

ager

:

Con

tact

Num

ber:

Em

ail:

Kel

ly L

ockh

art

(330

) 696

-580

9

kelly

.lock

hart

@ph

ilips

.com

* Countertop Height Guide:

30" (765mm) for standard seated height.36" (915mm) for standard standing height.

* Ensure that the wall junction boxes are mounted

perpendicular to the floor.* Verify exact ceiling height of Equipment and Control RoomArea.

* Architect to coordinate with end users/technicians todetermine final placement of control desk components priorto installation in order to avoid rework. Architect to

coordinate with Philips Project Manager to reflect finalplacement on Philips drawings.

Note: The use of 90 degree ells is not acceptable. Use 45

degree bends at all raceway corners. For raceway (conduit) runs,use the minimum bending radius specific to the raceway (conduit)

diameter. The use of crossover tunnels at all applicable locationsis required. The above mentioned recommendations will help toensure the integrity of the cables and fiber optic runs.

OUTLINED REVISIONS MADE FOR CLARIFICATION BY HEAPY ENGINEERING.

PROVIDE HINGED, CLEAR PROTECTIVE COVER.

TRANSFORMER REFERENCE GROUND.

20" 20"

20" 20"

24" 24" 8"

16" 16"

PROVIDE ROUGH-IN TO DOOR FRAME ONLY.

FLOOR REFER TO HEAPY DETAIL.

W LDS

ST

ST

1' - 10"

1' - 3"

2' - 11 3/16"

DS

W L

CB2

CB

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

12" = 1'-0"

E.E401

CATH LAB 4 - PHILIPSDRAW INGS

05/24/19

KMU

LLC

1 2019.05.24 PERMIT SET

Page 16: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

E3THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C1 AND SHOULD NOT BE SEPARATED.

Pro

ject

Det

ails

Phi

lips

Con

tact

sP

roje

ct

Dra

win

g N

umbe

r

N-M

ID19

0046

CD

ate

Dra

wn:

5/9

/201

9

Quo

te:

Ord

er:

Azu

rion

7 C

20

1.22.19

1-1Z

YV

Y3F

Rev

. 3

6600

4295

61.0

1000

0

THE

INF

OR

MA

TIO

N IN

TH

IS P

AC

KA

GE

IS P

RO

VID

ED

AS

A C

US

TOM

ER

CO

NV

EN

IEN

CE

, AN

D IS

NO

T TO

BE

CO

NS

TRU

ED

AS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

OR

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

.

Phi

lips

assu

mes

no

liabi

lity

nor o

ffers

any

war

rant

y fo

r the

fitn

ess

or a

dequ

acy

of th

e pr

emis

es o

r th

e ut

ilitie

s av

aila

ble

at th

e pr

emis

es in

whi

ch th

e eq

uipm

ent i

s to

be

inst

alle

d, u

sed,

or

stor

ed.

KM

CN

Gra

ndvi

ew H

ospi

tal

Day

ton,

OH

Roo

m: C

ath

Lab

4

© K

onin

klijk

e P

hilip

s E

lect

roni

cs N

.V. 2

019.

All

right

s re

serv

ed. R

epro

duct

ion

in w

hole

or

in p

art i

s pr

ohib

ited

with

out p

rior w

ritte

n co

nsen

t of t

he c

opyr

ight

hol

der.

Dra

wn

By:

Lynd

e D

. Pep

per

Pro

ject

Man

ager

:

Con

tact

Num

ber:

Em

ail:

Kel

ly L

ockh

art

(330

) 696

-580

9

kelly

.lock

hart

@ph

ilips

.com

Raceway (Conduit) Required

General Notes

1. All raceway (conduit) runs must take most direct route point to point.

Power (AC)Power (DC)GroundSignalHigh TensionCooling HoseAir Supply Hose

*

RunNo.

Raceway (Conduit)

From To

Raceway(Conduit)

Quantity

CableType

(*)

MinimumRaceway(Conduit)

Size

Maximum

(Raceway)ConduitLength

2. All raceway (conduit) runs must have a pull string.

PDGSHCA

Special Requirements

A Raceway (Conduit) supplied/installed by contractor - Philips cables installed by Philips

B Raceway (Conduit) supplied/installed by contractor - Philips cables installed by contractor

C Raceway (Conduits) and cables supplied and installed by contractor

D Raceway (Conduit) existing - cables supplied and installed by Philips

E Raceway (Conduit) existing - cables supplied by Philips and installed by contractor

F Raceway (Conduit) existing - cables supplied and installed by contractor

G Optional equipment, verify with local Philips Service

Raceway (Conduit) Required

General Notes

1. All raceway (conduit) runs must take most direct route point to point.

Power (AC)Power (DC)GroundSignalHigh TensionCooling HoseAir Supply Hose

*

RunNo.

Raceway (Conduit)

From To

Raceway(Conduit)

Quantity

CableType

(*)

MinimumRaceway(Conduit)

Size

Maximum

(Raceway)ConduitLength

2. A Greenlee pull string/measuring tape (part no. 435, or equivalent) must be provided with raceway (conduit) runs

PDGSHCA

Special Requirements

A Raceway (Conduit) supplied/installed by contractor - Philips cables installed by Philips

B Raceway (Conduit) supplied/installed by contractor - Philips cables installed by contractor

C Raceway (Conduits) and cables supplied and installed by contractor

D Raceway (Conduit) existing - cables supplied and installed by Philips

E Raceway (Conduit) existing - cables supplied by Philips and installed by contractor

F Raceway (Conduit) existing - cables supplied and installed by contractor

G Optional equipment, verify with local Philips Service

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

A VB1 MB 1 S 1" 82'

A VB2 MB 1 S 1" 82'

A VB3 MB 1 S 1" 82'

A VB4 MB 1 S 1" 82'

A VB5 MB 1 S 1" 82'

A VB6 MB 1 S 1" 82'

C MA WL 1 P 34 " 55'

C ATY DS 1 S 34 " 55'

A ATY MA 1 S 2 12 " 41'

A ATY TV 1 S 34 " 65'

A SP ME 1 P/G 1 12 " 39'

A SP ME 1 S 1" 39'

A SP ME 2 C 1 12 " 44' Tube Cooling Hoses.

A SP MR 1 P/G 2" 39'

A SP MR 1 S 2" 39'

A SP ME 1 H 2 12 " 37' High Tension Cables.

A SP MA 1 S 2" 37'

GThirdParty

ThirdParty

- - - -For Injector, Auxiliary Box, Patient Monitoring, VideoNetworking, etc.

GThirdParty ERB - G - -

For Injector, Auxiliary Box, Patient Monitoring, VideoNetworking, etc.C ERB GE 1 G 3

4 " 6'

C ERBRoom

Outlets1 G 3

4 " - See Sheet "ED2" for details.

C MSA WR3 2 S 1 12 " -

For future options (Patient Monitoring). Verify with localPhilips Service if auxiliary box should be used.

A MSA MA 1 S 2 12 " 39'

A MSA MR 1 S 2 12 " 39'

A MSA MR 1 P/G 2" 39'

A TV WM 1 S 34 " 65' For Intercom.

A TV MA 1 P 1 12 " 52'

A TV MA 1 S 2 12 " 52'

A TV MB 1 S 1 12 " 52' For FlexVision XL.

A TV MR 1 P 2" 52'

A CY MR 1 S 2" 55' Conduits to land on wall raceway adjacent to CY.

A CY MA 1 P/G 1 12 " 55' Conduits to land on wall raceway adjacent to CY.

A CY MA 1 S 2 12 " 55' Conduits to land on wall raceway adjacent to CY.

A MSA MA 1 P 1 12 " 39'

A TV MB 1 P/G 1 12 " 52'

A MR WM 1 S 1" 82' Conduits to land on wall raceway adjacent to CY.

A MB WM 1 S 1 12 " 82' For FlexSpot.

A VB11 MB 1 P 1 12 " 55' Monitor on Cart.

A VB11 MB 1 S 1 12 " 55' Monitor on Cart.

A VB10 MB 1 P 1 12 " 55' Monitor on Cart.

A VB10 MB 1 S 1 12 " 55' Monitor on Cart.

C CB2 UPS 1 P Per N.E.C. Per N.E.C.

C RSAP UPS 1 S Per N.E.C.Per N.E.C. For Remote Status Alarm Panel.

C UPS ST 1 S Per N.E.C.Per N.E.C.

C UPS CB 1 P Per N.E.C.Per N.E.C.

C CB ERB 2 G Per N.E.C.Per N.E.C. Conduit must hit WR2 raceway.

CPowerPanel

CB2 1 G Per N.E.C.Per N.E.C.

C UPS MA 1 S Per N.E.C.Per N.E.C.

C CB MA 1 P Per N.E.C. Per N.E.C. Conduit must hit WR2 raceway.

CPowerPanel

CB2 1 P Per N.E.C.Per N.E.C.

C BC UPS 1 P Per N.E.C. Per N.E.C.

C BC UPS 1 S Per N.E.C.Per N.E.C.

C CB2 ST 1 P Per N.E.C. Per N.E.C.

C UPS CB 1 G Per N.E.C.Per N.E.C.

C CB2 ERB 1 G Per N.E.C.Per N.E.C.

C MA ERB 1 G Per N.E.C.Per N.E.C.

C WR2 ERB 1 G Per N.E.C.Per N.E.C.

A VB7 MB 1 S 1" 82'

ED1THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C1 AND SHOULD NOT BE SEPARATED.

Pro

ject

Det

ails

Phi

lips

Con

tact

sP

roje

ct

Dra

win

g N

umbe

r

N-M

ID19

0046

CD

ate

Dra

wn:

5/9

/201

9

Quo

te:

Ord

er:

Azu

rion

7 C

20

1.22.19

1-1Z

YV

Y3F

Rev

. 3

6600

4295

61.0

1000

0

THE

INF

OR

MA

TIO

N IN

TH

IS P

AC

KA

GE

IS P

RO

VID

ED

AS

A C

US

TOM

ER

CO

NV

EN

IEN

CE

, AN

D IS

NO

T TO

BE

CO

NS

TRU

ED

AS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

OR

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

.

Phi

lips

assu

mes

no

liabi

lity

nor o

ffers

any

war

rant

y fo

r the

fitn

ess

or a

dequ

acy

of th

e pr

emis

es o

r th

e ut

ilitie

s av

aila

ble

at th

e pr

emis

es in

whi

ch th

e eq

uipm

ent i

s to

be

inst

alle

d, u

sed,

or

stor

ed.

KM

CN

Gra

ndvi

ew H

ospi

tal

Day

ton,

OH

Roo

m: C

ath

Lab

4

© K

onin

klijk

e P

hilip

s E

lect

roni

cs N

.V. 2

019.

All

right

s re

serv

ed. R

epro

duct

ion

in w

hole

or

in p

art i

s pr

ohib

ited

with

out p

rior w

ritte

n co

nsen

t of t

he c

opyr

ight

hol

der.

Dra

wn

By:

Lynd

e D

. Pep

per

Pro

ject

Man

ager

:

Con

tact

Num

ber:

Em

ail:

Kel

ly L

ockh

art

(330

) 696

-580

9

kelly

.lock

hart

@ph

ilips

.com

(19.0)

Branch Circuit and Wire Gauge Requirements (Mains 40E Cabinet)

Branch Power 100 kVA (System only; verify UPS power requirements)

Max. Standby Current 8 A per phase

Circuit Breaker (CB) 3 Phase, Type D 80 A with long-time delay

For information only. Terminal block accommodates #4 in mains cabinet. Engineer of record responsible for calculatingphase conductor and equipment ground conductor sizes. Recommended phase conductor and equipment ground conductor

sizes for 1% impedance of supply conductors to circuit breaker (CB).

Max. Instantaneous Power(at X-ray tube power 100 kV 1000mA current)

100 kW

Max. Inst. Current @ CB(RMS value over half-cycle)

300 A @480V

Max. Phase-phase impedance @ CRC 0.465 ©

Long Term Rating 63A at 480V

Momentary Rating (using a window of 5 seconds) 125A at 480V

CB

Power Quality Requirements (Mains 40E Cabinet)

Maximum Rated Power 100kW

Supply Configuration

3 phase, equally sized insulated power conductors and an insulated equipment groundingconductor. Insulated grounding conductor shall have the same or larger size than lineconductors. Line wires shall be no smaller than 6 AWG, 90°C temperature or higher temperature

rating. The conductor size is dependant on the upstream circuit breaker rating: Minimum 4 AWGfor 80 A circuit breaker rating.

Nominal Line Voltage 480 VAC, 60 Hz

Line Voltage VariationVoltage Variations are never to exceed ±10% when measured using 10 minute mean RMSvalues with a measurement window of 1 week. At least 95% of all measured 10 minute meanRMS values shall be within ±5% of the configured nominal voltage.

Line Voltage Balance 2% maximum of nominal voltage between phases

Frequency Variation ± 1.0 Hz

Voltage Surges To 110% of steady-state voltage 100 msecs. Maximum duration, 6 per hour max.

Voltage Sags To 90% of steady-state voltage 100 msecs. Maximum duration, 6 per hour max.

Line Impulses1000 VPK above phase-neutral RMS absolute maximum. No more than 1 impulse per hour toexceed 500 VPK.

Neutral-Ground Voltage 2.0 volts maximum RMS value

Neutral-Ground Impulses No more than 1 per hour that exceeds 25 volts and 1 milli-Joule

High Frequency Noise3.0 volts steady-state maximum. Over 3.0 volts permitted for 100 msec. maximum, 1 per hourmax.

Grounded ConductorImpedance

0.1 Ohms @ 60 hz. maximum

ED2THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C1 AND SHOULD NOT BE SEPARATED.

Pro

ject

Det

ails

Phi

lips

Con

tact

sP

roje

ct

Dra

win

g N

umbe

r

N-M

ID19

0046

CD

ate

Dra

wn:

5/9

/201

9

Quo

te:

Ord

er:

Azu

rion

7 C

20

1.22.19

1-1Z

YV

Y3F

Rev

. 3

6600

4295

61.0

1000

0

THE

INF

OR

MA

TIO

N IN

TH

IS P

AC

KA

GE

IS P

RO

VID

ED

AS

A C

US

TOM

ER

CO

NV

EN

IEN

CE

, AN

D IS

NO

T TO

BE

CO

NS

TRU

ED

AS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

OR

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

.

Phi

lips

assu

mes

no

liabi

lity

nor o

ffers

any

war

rant

y fo

r the

fitn

ess

or a

dequ

acy

of th

e pr

emis

es o

r th

e ut

ilitie

s av

aila

ble

at th

e pr

emis

es in

whi

ch th

e eq

uipm

ent i

s to

be

inst

alle

d, u

sed,

or

stor

ed.

KM

CN

Gra

ndvi

ew H

ospi

tal

Day

ton,

OH

Roo

m: C

ath

Lab

4

© K

onin

klijk

e P

hilip

s E

lect

roni

cs N

.V. 2

019.

All

right

s re

serv

ed. R

epro

duct

ion

in w

hole

or

in p

art i

s pr

ohib

ited

with

out p

rior w

ritte

n co

nsen

t of t

he c

opyr

ight

hol

der.

Dra

wn

By:

Lynd

e D

. Pep

per

Pro

ject

Man

ager

:

Con

tact

Num

ber:

Em

ail:

Kel

ly L

ockh

art

(330

) 696

-580

9

kelly

.lock

hart

@ph

ilips

.com

* ERB to be placed ata reachable height.

**Verify with Engineer

of Record and localcodes if additionalground bond wires are

required if theelectrical continuityrequirements for theraceway (wireway)system cannot be metvia the conduit hubs.

*ERB - Busbar

MBBox

MRBox

MEBox

Raceway

Raceway

Pass ThroughLug

#10 PanScrew

Detail - Grounding(Not to scale / Not site specific)

#6 AWG greenstranded wire

(16.0)

MABox

ECBPCBPPCB

**

**

**

**

**

**

**

2 12"

[64mm]

2 12"

[64mm]

43 4

"

[120

mm

]

734 "

[197mm]

51 2

"

[139

mm

]

31 4

"

[82m

m]

1. Furnished and installed by Contractor2. Purchase from local Ferraz Shawmut distributor,

http://www.ferrazshawmutsales.com/index.htmCatalog #69143.

3. 62000 - 69000 Series Blockshttp://www.ferrazshawmutsales.com/pdfs/PDB-LARGE.pdf

From

Circuit BreakerSize per

conductors

To Mains

40E Cabinet

To be installed in

12" (305mm) x 12"(305mm) x 4"

(105mm) cut-outbox or equivalent.

#6 AWG to metallic structure within patientvicinity AND to structural local building

steel used as potential reference forpatient vicinity but located in the technical

room within 6 foot reach

Ensure bondingbetween ground pin ofsupply socket outlets to

the PCB terminal isbetter than 100 mOhm.

To equipment powered

from the Azurion branchcircuit. I.e. equipmentallowed inside theAzurion ground domain.

Conductor sizes#14 - #4 AWG

Detail - Equi-Potential Reference Bar Application(Not to scale)

ERB (16.0)

Invasive Procedures

This equipment may be used for invasiveprocedures; therefore, the area to be installed

is classified as critical care area per NFPA-99and NFPA-70 (NEC). These documents

specify maximum touch voltages and groundimpedance in these areas.

Test performed by GSSNA service require thatthese specifications are met by the GSSNA

equipment. It is the facility's responsibility toensure that these specifications are met by the

wall outlet, facility structure, and otherequipment not installed by GSSNA.

The GSSNA specified "Equi-Potential

Reference Bar (ERB)" serves as a groundreference for GSSNA equipment. It may also

serve as the "Reference Grounding Point" ofthe room as defined in NFPA 99-3.3.140 fornon-Philips Healthcare equipment.

Equi-Potential Reference Bar (ERB)

A) Equip-Potential Conductor Bar (ECB)B) Protective Conductor Bar (PCB)

C) Philips Protective Conductor Bar (PPCB)

ECB PCB PPCB

ED3THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C1 AND SHOULD NOT BE SEPARATED.

Pro

ject

Det

ails

Phi

lips

Con

tact

sP

roje

ct

Dra

win

g N

umbe

r

N-M

ID19

0046

CD

ate

Dra

wn:

5/9

/201

9

Quo

te:

Ord

er:

Azu

rion

7 C

20

1.22.19

1-1Z

YV

Y3F

Rev

. 3

6600

4295

61.0

1000

0

THE

INF

OR

MA

TIO

N IN

TH

IS P

AC

KA

GE

IS P

RO

VID

ED

AS

A C

US

TOM

ER

CO

NV

EN

IEN

CE

, AN

D IS

NO

T TO

BE

CO

NS

TRU

ED

AS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

OR

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

.

Phi

lips

assu

mes

no

liabi

lity

nor o

ffers

any

war

rant

y fo

r the

fitn

ess

or a

dequ

acy

of th

e pr

emis

es o

r th

e ut

ilitie

s av

aila

ble

at th

e pr

emis

es in

whi

ch th

e eq

uipm

ent i

s to

be

inst

alle

d, u

sed,

or

stor

ed.

KM

CN

Gra

ndvi

ew H

ospi

tal

Day

ton,

OH

Roo

m: C

ath

Lab

4

© K

onin

klijk

e P

hilip

s E

lect

roni

cs N

.V. 2

019.

All

right

s re

serv

ed. R

epro

duct

ion

in w

hole

or

in p

art i

s pr

ohib

ited

with

out p

rior w

ritte

n co

nsen

t of t

he c

opyr

ight

hol

der.

Dra

wn

By:

Lynd

e D

. Pep

per

Pro

ject

Man

ager

:

Con

tact

Num

ber:

Em

ail:

Kel

ly L

ockh

art

(330

) 696

-580

9

kelly

.lock

hart

@ph

ilips

.com

WR1 WR2 WR3(16.0)

Signal, Dataand Video

(if not in conduit)

OutputPower

+PE

Input Power+PE

Detail - Cable Trough Divisions(Not to scale)

High-Voltage

Contractors to discuss raceway plan with Philips Project Manager.Raceways (troughs or ducts) may be separated by metal barriers into foursections. Only required separation if for Group A wires that must be

separated from other groups. See sheet EN for more information:1. Supply Mains conductors and associated PE.

2. Secondary Circuit (Azurion equipment internal single phase 230Vac)conductors and associated PE.

3. High-Voltage wire harness to X-Ray stands.4. Signal, data and video cables.

5. It is important that all cables are placed in the appropriate raceway

(trough), and at no given point do any cables from one division crosscables from another. Trough separation must be continuous from thebeginning.

6. Raceway (trough or ducts): steel with steel dividers grounded tobuilding ground.

7. Contractor to provide cable restraints in all troughs.

ME MR MA MB

DSWL (16.0)

X106:2

(NC)n.o.

n.c.

Com

Diagram - Typical Connection ofX-Ray In-Use Light, Exam Room Lights, & Door Switch

* The 110V relay should have heavy-duty contacts to handle the room lights current. All items shown (except Philips items) to be supplied by Contractor.

X106:3(P)

X106:1(NO)

Philips"MA" Rack

To room lightscircuit

Supplied by Contractor.Contractor to locate relaybox in ceiling space away

from Philips equipment.

110V Relay*

The system can be configured by

software to turn off the desiredexam room lights everytimeduring exposures or the examroom lights can be set to turnon/off manually by the Philipsfootswitch. Verify with customerwhich exam room lights arecontrolled.

Hospital supplied 110 VAC

Contractor to provide switch legs to

Philips "MA" Rack. Switch leg voltagecannot be greater than 120 VAC.

X105:2(NC)

X105:3(P)

X105:1(NO)

Philips"MA" Rack

The X-ray "In-Use" indicatorlight(s) must be energizedeverytime during exposures.

24V Relay

Xray "In-Use"Light

NHospital supplied

110 VAC

Hospital supplied

24 VAC

Philips"ATY" box

X2:1

X2:2

Door Switch

Optional door switch.Supplied by Contractor andContractor to provide switchleg to the Philips ATY box.

Supplied by Contractor.Contractor to locate relaybox in ceiling space awayfrom Philips equipment.

Contractor to provide switch legs toPhilips "MA" Rack.

N

N

These interface designators andphysical connector types havebeen changed since Azurion.

These interface designators andphysical connector types havebeen changed since Azurion.

Wall Duct

Finished Floor

Wall Duct

Pop-rivets on topand bottom can beremoved for directintegration withraceway ducts. DO

NOT remove topand bottom ifraceway via conduithubs is used.

(16.0)

Detail - Back Box Mounting(Not to scale)

5"

[127

mm

]

5'-7

"

[170

2mm

]

Wall racewayraised above

finished floor

OUTLINED REVISIONS MADE FOR CLARIFICATION BY HEAPY ENGINEERING.

NOT REQUIRED.

REFER TO SINGLE LINE.

REFER TO SINGLE LINE.

#2 AW G PER SHEET ED4.

2-250 KCMIL PER SHEET ED5.

2-250 KCMIL PER SHEET ED5.

REFER TO SINGLE LINE.

3 - #12 IN 0.75" C .

3 - #12 IN 0.75" C .

REFER TO SINGLE LINE.

3 - #2, 1 - #2 GRD. IN 1.25" C.

PER MANUFACTURER 'S REQUIREMENTS.

C 59 MGP W R3 1 1 1/2" SPARE FOR FUTURE.

NOT REQUIRED.

CONTRACTOR

CONTRACTOR

CONTRACTOR

PROVIDE 100VA 120V-24V CONTROL TRANSFORMER EQUAL TO SQ. D TYPE "T" FOR 24V POW ER.

E87-CB-2

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

12" = 1'-0"

E.E402

CATH LAB 4 - PHILIPSDRAW INGS

05/24/19

KMU

LLC

1 2019.05.24 PERMIT SET

Page 17: Grandview Medical Center · 1 2 1 p2 b p2 general floor plan notes riser or stack number detail: b = detail designation p2 = sheet where detail is located fire suppression hazard

ED4THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C1 AND SHOULD NOT BE SEPARATED.

Pro

ject

Det

ails

Phi

lips

Con

tact

sP

roje

ct

Dra

win

g N

umbe

r

N-M

ID19

0046

CD

ate

Dra

wn:

5/9

/201

9

Quo

te:

Ord

er:

Azu

rion

7 C

20

1.22.19

1-1Z

YV

Y3F

Rev

. 3

6600

4295

61.0

1000

0

THE

INF

OR

MA

TIO

N IN

TH

IS P

AC

KA

GE

IS P

RO

VID

ED

AS

A C

US

TOM

ER

CO

NV

EN

IEN

CE

, AN

D IS

NO

T TO

BE

CO

NS

TRU

ED

AS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

OR

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

.

Phi

lips

assu

mes

no

liabi

lity

nor o

ffers

any

war

rant

y fo

r the

fitn

ess

or a

dequ

acy

of th

e pr

emis

es o

r th

e ut

ilitie

s av

aila

ble

at th

e pr

emis

es in

whi

ch th

e eq

uipm

ent i

s to

be

inst

alle

d, u

sed,

or

stor

ed.

KM

CN

Gra

ndvi

ew H

ospi

tal

Day

ton,

OH

Roo

m: C

ath

Lab

4

© K

onin

klijk

e P

hilip

s E

lect

roni

cs N

.V. 2

019.

All

right

s re

serv

ed. R

epro

duct

ion

in w

hole

or

in p

art i

s pr

ohib

ited

with

out p

rior w

ritte

n co

nsen

t of t

he c

opyr

ight

hol

der.

Dra

wn

By:

Lynd

e D

. Pep

per

Pro

ject

Man

ager

:

Con

tact

Num

ber:

Em

ail:

Kel

ly L

ockh

art

(330

) 696

-580

9

kelly

.lock

hart

@ph

ilips

.com

480VFacility

Distribution(Solidly grounded

Wye sourcerequired. No

neutral conductorneeded.)

Ask Philips PM tocontact zone

power specialist ifmore info is

needed.

150 ACircuit Breakerwith Shunt Trip

Legend

Wiring and Connections made by Contractor. PE wiring

for internal connections isolated from the metal casing.

Wiring provided by Philips and connected by Contractor

Diagram - Standard Top Feed Connection (18.1)

(Source associated

ground fault wirefor protective

earthing of class

Type-I enclosures)

#6 Ground

120V AC Outlet

Remote StatusAlarm Panel

Wall mounted incontrol room

EPO Switch

Galaxy 5000

80 kVA UPS

UPS

CRC

MA

"Main"Cabinet

Philips CV System

CB2

ST

RSAP

80 A

(Downstream Fuse)Circuit Breaker

CB

BC

Battery Pack

Converter

3 phase

UPSInput

Note:

All Power Cables shall be in separate conduits from control andcommunication cables.

Note: EPOconnection to UPS is

a NC (normally

closed contact)

Top FeedCabinet

Input

Max. 6 feet groundconnection to local

building steel.

2 AWG Ground

3 phaseUPS Output

Output

DC

DCComm

DC

*ERB - Busbar

ECBPCBPPCB

CRC Cover with terminal blocks.

(CRC Cover can be a pre-delivery item.Part #989710006001

Terminal blocks come with MA rack andcannot be a pre-delivery item.To be installed by contractor.)

2 AWGGround

2 AWGGround

2 AWGGround

2x 6 AWGGround

Wiring and circuit sizes from sourcesupply must meet Philips regulationrequirements and must bedetermined by contractor to meetbuilding conditions and local codes.3 Phase, + PE (Protective Earth).

**Same feeder and ground sizes perconductor/ground size chart

Keep all line phase wires andground wires together to minimize

unintended magnetic fields in caseof ground faults.

3 Phase

4 AWG

On Emergency Power

Isolated NOcontacts

Unshielded Signal Cable (e.g. #26, #22) 3 Wire

WR2

4 AWGGround

Wiring and Connections made by Contractor. PE wiring connectionsthat are connected to metal casing (e.g. outer housing, busbar).

ED5THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C1 AND SHOULD NOT BE SEPARATED.

Pro

ject

Det

ails

Phi

lips

Con

tact

sP

roje

ct

Dra

win

g N

umbe

r

N-M

ID19

0046

CD

ate

Dra

wn:

5/9

/201

9

Quo

te:

Ord

er:

Azu

rion

7 C

20

1.22.19

1-1Z

YV

Y3F

Rev

. 3

6600

4295

61.0

1000

0

THE

INF

OR

MA

TIO

N IN

TH

IS P

AC

KA

GE

IS P

RO

VID

ED

AS

A C

US

TOM

ER

CO

NV

EN

IEN

CE

, AN

D IS

NO

T TO

BE

CO

NS

TRU

ED

AS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

OR

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

.

Phi

lips

assu

mes

no

liabi

lity

nor o

ffers

any

war

rant

y fo

r the

fitn

ess

or a

dequ

acy

of th

e pr

emis

es o

r th

e ut

ilitie

s av

aila

ble

at th

e pr

emis

es in

whi

ch th

e eq

uipm

ent i

s to

be

inst

alle

d, u

sed,

or

stor

ed.

KM

CN

Gra

ndvi

ew H

ospi

tal

Day

ton,

OH

Roo

m: C

ath

Lab

4

© K

onin

klijk

e P

hilip

s E

lect

roni

cs N

.V. 2

019.

All

right

s re

serv

ed. R

epro

duct

ion

in w

hole

or

in p

art i

s pr

ohib

ited

with

out p

rior w

ritte

n co

nsen

t of t

he c

opyr

ight

hol

der.

Dra

wn

By:

Lynd

e D

. Pep

per

Pro

ject

Man

ager

:

Con

tact

Num

ber:

Em

ail:

Kel

ly L

ockh

art

(330

) 696

-580

9

kelly

.lock

hart

@ph

ilips

.com

Input Bypass Output Battery

Input VoltageNominal Input

Current

(A) *1

Maximum InputCurrent

(A) *2

Input CurrentLimitation

Input PhaseRotation

(A) *3

RecommendedOvercurrentProtection

Nominal BypassCurrent

Nominal OutputCurrent

RecommendedOvercurrentProtection

NominalDischarge

(A) *4

Max. Discharge

(A) *5

80 kVA 98 111 111 A, B, C clockwise 150 94 94 125 180 219

* NOTES:1) Input current based on rated load and batteries fully charged.

2) Input current based on full battery recharge, nominal voltage, and rated load.3) Nominal Voltage - 10% voltage with partial recharge.

4) Nominal battery discharge current based on rated load and nominal battery voltage.5) Maximum battery discharge based on rated load at the end of the discharge.

80 kVA UPS Cabinet - 480V

Notes for Recommended Cable Sizes:

All wiring must comply with all applicablenational and/or electrical codes. Cable sizes in

this manual are based on table 310-16 of theNational Electrical Code (NEC) with the

following assertions: 90 degree conductors(THHN) for 75 degree Celcius termination and

the use of copper conductors. Recommended75 degrees Celcius cable sizes below are for

480V input/output UPS, depending uponrecommended over current protection stated.

Ground wires are sized in accordance withNEC Article 250-122 and Table 250-122.Power and control communication cables mustbe routed in separate conduits.

Recommended Battery Cable Sizes

Battery CircuitBreaker rating (A)

Cable Size

250 250 kcmil

UPS

Q3BP

Output

Q5NInver ter

OutputStaticSwi tch

InputStaticSwi tch

Bat teryCharger

PFCBoost

Rect if ier

BypassStaticSwi tch

G

DALI N PCA

XMB07

TB5

7

QF1

8

G

6

OutputFuses

From Utility

Source

To CriticalLoad

BypassInput

Bat teryStaticSwi tch

Bat tery

Q4S

Q1

KA2

InputFuses KA1

C

A

B

C

A

B

C

A

B

G G

Bypass

Supplied By Schneider Electric

& Connected by ContractorSupplied & Connected byContractor

Supplied By Schneider Electric

& Connected By Contractor

Output

C

A

B

Top Entry

ED6THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C1 AND SHOULD NOT BE SEPARATED.

Pro

ject

Det

ails

Phi

lips

Con

tact

sP

roje

ct

Dra

win

g N

umbe

r

N-M

ID19

0046

CD

ate

Dra

wn:

5/9

/201

9

Quo

te:

Ord

er:

Azu

rion

7 C

20

1.22.19

1-1Z

YV

Y3F

Rev

. 3

6600

4295

61.0

1000

0

THE

INF

OR

MA

TIO

N IN

TH

IS P

AC

KA

GE

IS P

RO

VID

ED

AS

A C

US

TOM

ER

CO

NV

EN

IEN

CE

, AN

D IS

NO

T TO

BE

CO

NS

TRU

ED

AS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

OR

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

.

Phi

lips

assu

mes

no

liabi

lity

nor o

ffers

any

war

rant

y fo

r the

fitn

ess

or a

dequ

acy

of th

e pr

emis

es o

r th

e ut

ilitie

s av

aila

ble

at th

e pr

emis

es in

whi

ch th

e eq

uipm

ent i

s to

be

inst

alle

d, u

sed,

or

stor

ed.

KM

CN

Gra

ndvi

ew H

ospi

tal

Day

ton,

OH

Roo

m: C

ath

Lab

4

© K

onin

klijk

e P

hilip

s E

lect

roni

cs N

.V. 2

019.

All

right

s re

serv

ed. R

epro

duct

ion

in w

hole

or

in p

art i

s pr

ohib

ited

with

out p

rior w

ritte

n co

nsen

t of t

he c

opyr

ight

hol

der.

Dra

wn

By:

Lynd

e D

. Pep

per

Pro

ject

Man

ager

:

Con

tact

Num

ber:

Em

ail:

Kel

ly L

ockh

art

(330

) 696

-580

9

kelly

.lock

hart

@ph

ilips

.com

Diagram - Remote Status Alarm PanelInterconnection for Galaxy 5000 w/ SECI

(17.0)

NOTES:1. INSTALLATION SHALL COMPLY WITH ALL

APPLICABLE NATIONAL AND LOCAL CODES.

2. PLEASE REFER TO PRODUCT MANUALS FORADDITIONAL DETAILS.

3. CONNECT TO EITHER TB3-11 OR TB3-12 INRASP.

4. REFER TO THE SPECIFIC RASP INSTALLATION

DRAWING FOR SINGLE UPS.

!3

RSAP

OUTLINED REVISIONS MADE FOR CLARIFICATION BY HEAPY ENGINEERING.

BOND TO 500 KVA TRANS. REFERENCE GROUND.

2

Kettering Health Network

Grandview Medical Center

KEY PLAN:

REVISIONS:

NOTES:

Date

Checked By

Drawn By

Job No. Sheet No.

No. Date Description

405 W. GRAND AVE. DAYTON, OHIO 45405

CATH LAB#4 RENOVATION

3rd Floor

www.pinnaclearchitects.comPHONE: 937. 222. 1117 FAX: 937. 222. 4893

MIAMISBURG, OH 45342480 VANTAGE POINT, SUITE 201

1400 W Dorothy Lane, Dayton, OH 45409

P: 937-224-0861 www.heapy.com

PRO JECT NO. OHIO COA FIRM NO. 015282018-05059.01

12" = 1'-0"

E.E403

CATH LAB 4 - PHILIPSDRAW INGS

05/24/19

KMU

LLC

1 2019.05.24 PERMIT SET