GRADER TECHNICAL FEATURES€¦ · p1 =6000 nl/h (7 bar) connection pipe to main water system...
Transcript of GRADER TECHNICAL FEATURES€¦ · p1 =6000 nl/h (7 bar) connection pipe to main water system...
Loading Dock1.3m Deep from Top of Slab
3800
Note:
TODDCO107-H1
DOCK LEVELER
w/ 600 DEEP PIT
3 S2
4S2
LEGEND
- - - A1
CHEEKY FARMS
GROUND FLOOR PLANLOT 1651 CONNELLY RD.,LAMBELLS LAGOONPROPOSED MANGO PACKING SHED
Mobile: 0427 411 633 Email: [email protected]
Engineers
Consulting
Northern Territory, Australia
P.O. Box 900
COOLALINGA 0839
ABN 73 102 631 186
N.T. Consulting Engineers
www.ntconsultingengineers.com.au
CONNECTION POINT TO MAIN ELECTRICAL WIRING
P2 =1000 nl/h
TOTAL COMPRESSED AIR CONSUMPTION 8.000 nl/h
TOTAL INSTALLED ELECTRIC POWER 53 KW 3Ph+ N + G
GRADER TECHNICAL FEATURES
CONNECTION TO COMPRESSED AIR SYSTEM MIN. 6bar, dry, clean and oil-free air
E2 = 30 kW
(This is just an estimation. We don't know exactly the application so we don't know exactly the number of cycles)
P1 =6000 nl/h (7 BAR)
CONNECTION PIPE TO MAIN WATER SYSTEM (INLET)
CONNECTION PIPE MAIN DRAINAGE SYSTEM (OUTLET)
TOTAL WATER CONSUMPTION (by AS) 75 L/m
E1 = 23 kW
P3 =1000 nl/h
Internet connection@
SCALE: 1:200GROUND FLOOR PLAN
1S2
WINDOW & DOOR SCHEDULE
ALL PERSONAL ACCESS DOORS
TO BE 920 WIDE LEAF x 2040 HIGH PAD
3200W x 4500H PROPRIETARY ROLLER DOORRD1
Note:
2S2
DESIGN CRITERIA
Terrain Category 2
Region C
Regional Wind Velocity = 69.3 m/s
5250W x 6000H PROPRIETARY ROLLER DOORRD2
1000W x 2100H PERSONAL ACCESS DOORD1
D2
FITTINGS & FIXTURES
wc toilet
ur urinal
sh shower
s sink
r wardrobe
wm washing machine
hb hand basin
vb vanity basin
db double hand basin
lt laundry tub
2750W x 3700H PROPRIETARY PANELIFT DOOR
BOLLARD AS DETAILED
6123
102666
6123
68
52
62
50
62
50
62
50
6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000
68
52
62
50
62
50
62
50
51
62
3
31
73
30
77
1550
OF
FIC
E
Maler
vb
wc
wc
vbvb
Female
UnisexAccesible
wc
LU
NC
HR
OO
M
10
0
29
50
10
0
10
01
00
10
0
10
0
15450
210210
21
02
10
32
52
80
80
23
20
80
2490
12
94
8
10
0
12
18
0
10
0
817515450
COOLROOM
COOLROOM
8m0 40
SCALE: 1:200
Note:
1 2 3 4 +15 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
P3
@
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
1000
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
600x400
1250
43
7
P2
P1
W1
W2
2940
11
24
0
65
40
C
3
hb
MSB
29
50
29
50
29
50
29
50
COOLROOM
COOLROOM
COOLROOM
COOLROOM
wcwc
sh
r
vb
wc
wc
vbvb
wcwc
sh
r
r
100100100100
15
35
0
80
32
52
500
79
0
SLAB EDGE
tundish
tundish
20438
Center of Loading Dock
Sla
b E
dg
e
- - - A32
CHEEKY FARMS
ELEVATIONSLOT 1651 CONNELLY RD.,LAMBELLS LAGOONPROPOSED MANGO PACKING SHED
Mobile: 0427 411 633 Email: [email protected]
Engineers
Consulting
Northern Territory, Australia
P.O. Box 900
COOLALINGA 0839
ABN 73 102 631 186
N.T. Consulting Engineers
www.ntconsultingengineers.com.au
ELEVATION 3
2°2°
2°2°
ELEVATION 4
ELEVATION 2
U795483-S26
2°2°
ELEVATION 1
SITE PLANLOT 1651(100) CONNELLY Rd LAMBELLS LAGOON
PROPOSED MANGO PACKING SHEDANDREW MUSUMECI
Mobile: 0427 411 633 Email: [email protected]
Engineers
Consulting
Northern Territory, Australia
P.O. Box 900
COOLALINGA 0839
ABN 73 102 631 186
N.T. Consulting Engineers
SITE PLAN
SCALE 1:5000
LEGEND
RN033705
RN033796
10
0m