GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

20
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010 HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

description

GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series. SoftGOT-GOT Link function – Remote Maintenance for GOTs!. The SoftGOT-GOT link function enables GT SoftGOT1000 to connect the GOT via Ethernet. - PowerPoint PPT Presentation

Transcript of GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Page 1: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

GOT1000 SeriesSoftGOT-GOT Link Function for GT15 and GT16 series

Page 2: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

SoftGOT-GOT Link function – Remote Maintenance for GOTs!

• The SoftGOT-GOT link function enables GT SoftGOT1000 to connect the GOT via Ethernet.

• The function synchronizes SoftGOT1000 data with GOT project data and resource data.

• This function is available for:

(GT12 not supported yet)

Page 3: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

GT15/GT16

EthernetWorksite Office

SoftGOT

QPLC

Serial/BUS/Ethernet

OperationOperationinterlockinterlock

HUB HUB

Up to 99 GOTs can Up to 99 GOTs can be monitored on a be monitored on a

single PCsingle PC

Automatically upload the project data from connected GOTs

⇒ No need to create the project No need to create the project data for SoftGOT!!data for SoftGOT!!

Interlock operations with GOT and SoftGOT⇒ Prevent unexpected Prevent unexpected behaviors!!behaviors!!

Data auto Data auto uploadupload

System overview

Note! FX PLCs will be supported in one of the next development steps (no schedule yet)

Page 4: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

GT15/GT16

Ethernet

Worksite Office

SoftGOT

QPLC

RS232/RS422/QBUS

Read/write devicesRead/write devicesvia GOTvia GOT

1) QBUS/serial connection between GOT and 1) QBUS/serial connection between GOT and PLCPLC

SoftGOT reads/writes devices in a PLC via GOT.(Ethernet Transparent Function)

Configuration (Connection Type)

Page 5: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

Worksite Office

Read/write devicesRead/write devicesby directly connecting to PLCby directly connecting to PLC

2) Ethernet connection between GOT and PLC2) Ethernet connection between GOT and PLC

SoftGOT reads/writes devices in a PLC by directlyconnecting to the PLC via Ethernet, not via GOT.

Configuration (Connection Type)

GT15/GT16

RS232/RS422/QBUS

QPLC

SoftGOT

Page 6: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

Data Auto Data Auto Acquisition Acquisition FunctionFunction

OperationOperationInterlockInterlock

•Project data auto acquisition functionSoftGOT automatically acquires GOT screen data (project data).There is no need to create the project data for SoftGOT.

•Alarm data auto acquisition functionSoftGOT automatically acquires the alarm data of GOT. Alarms that are already restored before connecting to SoftGOT can also be viewed.

In both functions, the data stored in SoftGOT will beupdated every time the SoftGOT is started up.

•Operating authorityEither one of SoftGOT or GOT can be operable to prevent the simultaneous operation from both sides that may cause unexpected behaviors.

•Operating authority (only GOT side) A mode to make only GOT operable.

Until this mode is cancelled on a GOT, SoftGOT is notoperable.

Features

Page 7: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

Interlock operations with SoftGOT and GOT to prevent simultaneous operation on both sides.

GT15/GT16

Worksite Office

SoftGOT

QPLC

Operation interlockOperation interlock

Operable (withoperating authority)

×

Obtain operating authority Obtain operating authority on the operating authority on the operating authority acquisition screenacquisition screen

Operable (with operating authority)×

Not operable (no operating authority)

Operation is prohibited on Operation is prohibited on the GOT that had the GOT that had operating authority operating authority before.before.

Move Move operating operating authorityauthority

Not operable(without operating authority)

Operation Interlock – Operating Authority

Page 8: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

Provides a mode to operate PLC only by GOT to preventthe operating authority from being moved to SoftGOT.

Worksite OfficeOperation interlockOperation interlock

Operable×

• Not operable until GOT cancels theoperating authority priority

• SoftGOT cannot enable/cancel theoperating authority priority

The operating authority can be enabled/cancelled only on the GOT side by using switches or utility functions on the GOT.

If operating authority is enabled…If operating authority is enabled…

Not operable

Operation Interlock – Operating Authority

GT15/GT16

SoftGOT

QPLC

Page 9: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

Required Hardware

• All GT15 models plus GT15-J71E71-100 Ethernet module

• All GT16 models using integrated Ethernet port

• Any Q CPU (only Q!)

Page 10: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

Required Software

• GT Works 3 V1.10L with– GT Designer 3 V1.10L

– SoftGOT1000 3.10L

Page 11: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

OS Installation -> GT15/GT16

• TransferextendedOS intoGOT!

Page 12: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

GT Designer 3 Project Settings

Decide how to use the SoftGOT:1. GOT and SoftGOT should always show

the same screen: Use PLC Register (D) as Screen switching device!

2. SoftGOT should act as separate HMI showing different screens as GOT:Use GOT Register (GD) as Screen switching device!

Page 13: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

SoftGOT settings

• Start SoftGOT1000 and open Communication settings

QCPU serial or QBUS connection QCPU Ethernet connection

Page 14: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

SoftGOT settings

1. Test GOT Link

Make sure to enter the IP-addressof the GOT (not the PLC!)

Page 15: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

SoftGOT settings

2. Start Monitor3. SoftGOT will

work for 2hwithout dongle!

4. GOT project will be uploadedto SoftGOTautomatically!

5. Monitoring willstart

Page 16: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

Page 17: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

Good to know!

Page 18: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

Good to know!

• Use internal GOT devices to control operation method effectively!

Page 19: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

Manual references

Page 20: GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010

HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

This is the first time to have This is the first time to have an Ethernet Remote an Ethernet Remote

Maintenance function in the Maintenance function in the GT15/GT16!GT15/GT16!

Let’s got out to customersLet’s got out to customerspromoting and selling it!promoting and selling it!

Thank you for your attentionThank you for your attention