Glidevale Ground Floor Protection MEMBRANES. GROUND FLOOR PROTECTION, GAS AND DAMP BARRIERS PROTECT...

12
CI/SfB (13.9) Uniclass Ss_32_20_30_48 November 2017 ................................ GROUND FLOOR PROTECTION & DAMP BARRIERS G lidevale offers a complete range of protection for ground floors against both damp and gases from the ground. This double function avoids the need for a damp-proof membrane in addition to a gas-tight membrane. Purpose-designed accessories make it easy to ensure reliable and continuous protection across wall cavities and at corners, columns, pipe penetrations etc. The range also includes components for ventilation of underfloor spaces where provided. PROTECT GDB10 PLUS Approved under BS 8485:2015. For use on sites affected by methane & carbon dioxide. Suitable for use in Amber 1 & Amber 2 situations. Protection against Methane Radon Carbon dioxide Hydrocarbons Damp

Transcript of Glidevale Ground Floor Protection MEMBRANES. GROUND FLOOR PROTECTION, GAS AND DAMP BARRIERS PROTECT...

CI/SfB (13.9) Uniclass Ss_32_20_30_48November 2017

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

GROUND FLOOR PROTECTION & DAMP BARRIERS

Glidevale offers a complete rangeof protection for ground floorsagainst both damp and gases

from the ground. This double functionavoids the need for a damp-proof membrane in addition to a gas-tightmembrane.

Purpose-designed accessories make it easyto ensure reliable and continuous protectionacross wall cavities and at corners,columns, pipe penetrations etc. The rangealso includes components for ventilation ofunderfloor spaces where provided.

PROTECT GDB10 PLUS

Approved under BS 8485:2015.

For use on sites affected by methane

& carbon dioxide. Suitable for

use in Amber 1 &

Amber 2 situations.

Protection against

● Methane

● Radon

● Carbon dioxide

● Hydrocarbons

● Damp

61740 Glidevale Ground Floor Protection 12pp_Glidevale Ground Floor Protection 05/12/2017 06:34 Page 2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CONTENTS

Introduction to ground floor protection 3

Technical requirements 4

Barrier membranes, Protect GDB10 PLUS, Radon 1200and self-adhesive gas resistant dpc/membrane 6

Preformed accessories 8

Underfloor and cavity wall vents 9

Application details 10

Specification clauses 11

Further information 12

2

61740 Glidevale Ground Floor Protection 12pp_Glidevale Ground Floor Protection 05/12/2017 06:34 Page 3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .GROUND FLOOR PROTECTION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The requirementHarmful ground gases entering buildingscan pose health risks. Damp can similarlycause health problems and also damage tothe building fabric.

Protective measures are therefore usuallyrequired in ground floors and theserequirements are enshrined in buildingregulations (see Technical requirements).

Government planning policy requires anincrease in the amount of housing onbrownfield land. This means that muchmore housing will need protection fromground gases.

Current high levels of thermal insulation andmodern construction methods requireventilation within the building fabric toprevent the build-up of moisture andcondensation.

The Glidevale complete solutionGlidevale ground floor protection productsoffer a complete solution:

● A continuous impermeable protectivebarrier against gases from the groundand damp penetration.

● A single barrier avoiding the need for anadditional damp-proof membrane.

● Continuity of protection at edges andpenetrations by means of purpose-designed accessories.

● Ventilation of underfloor spaces and wallcavities to remove gases and moisturevapour where required.

● Easy and reliable installation usingpreformed components.

● Can be used for solid ground floor slabsand for suspended concrete or timberfloors.

● Can be used to meet the requirements ofBuilding Regulations in the UK andIreland (see Technical requirements).

CertificationThe performance of Protect GDB10 PLUSmembrane has been independentlyassessed and certified by BM TRADACertification for use in ground floors ofbuildings as a barrier against harmful gases(radon, methane and carbon dioxide) anddamp penetration. Certificate number CPS-003.

CPS-003

Introduction 3

Technical requirements 4

Barrier membranes 6Protect GDB10 PLUS, Radon 1200 and self adhesive gas resistant dpc/membrane

Preformed accessories 8for edges, corners, pipe penetrations etc

Underfloor and cavity 9wall vents

Application details 10

Specification clauses 11

Further information 12

.

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The Glidevale complete solutionGlidevale ground floor protection products offer a complete solution:

● A continuous impermeable protective barrier against gases from the ground and damp penetration.

● A single barrier avoiding the need for an additional damp-proof membrane.

● Continuity of protection at edges and penetrations by means of purpose-designed accessories.

● Ventilation of underfloor spaces and wall cavities to remove gases and moisture vapour where required.

● Easy and reliable installation using preformed components.

● Can be used for solid ground floor slabs and for suspended concrete floors.

● Can be used to meet the Requirements ofBuilding Regulations in the UK and Ireland(see Technical Requirements section).

CertificationProtect GDB10 PLUS has been tested inaccordance with BS 8485:2015. The performance of Protect GDB10 PLUS membrane has also been independently assessed and certified by BM TRADA Certification for use in ground floors ofbuildings as a barrier against harmful gases(radon, methane and carbon dioxide) anddamp penetration. Certificate number CPS-003.

The RequirementHarmful ground gases entering buildingscan pose health risks. Damp can similarlycause health problems and also damagethe building fabric.

Protective measures are therefore usuallyrequired in ground floors and these Requirements are enshrined in Building Regulations (see Technical Requirementssection).

Government planning policy requires an increase in the amount of housing onbrownfield land. This means that muchmore housing will need protection fromground gases.

61740 Glidevale Ground Floor Protection 12pp_Glidevale Ground Floor Protection 05/12/2017 06:35 Page 4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TECHNICAL REQUIREMENTS

GROUND FLOOR PROTECTION, GAS AND DAMP BARRIERS

Harmful soil gasesHarmful soil gases such as methane,carbon dioxide and radon can enterproperties by different routes: throughcracks in floors and walls, constructionjoints, wall cavities, and around servicespipes.

Methane is a colourless, odourless, explosive and asphyxiatinggas.

Carbon dioxide (CO2) is a colourless, odourless, non-flammable,asphyxiating and toxic gas.

Methane and carbon dioxide can arise from landfill sites, mineworkings, and organic-rich soils such as peat or river silt.

Radon is a naturally-occurring colourless, odourless radioactivegas; some parts of the country have higher levels than elsewhere.Exposure to high levels of radon for long periods increases the riskof developing lung cancer.

Building Regulations (England and Wales)Protection against ground contaminantsand moisture are specific requirements ofthe Building Regulations Part C for Englandand Wales. The relevant requirements are:

Approved Document CSite preparation and resistance tocontaminants and moisture

‘Preparation of site and resistance tocontaminants C1 (2) Reasonableprecautions shall be taken to avoid dangerto health and safety caused bycontaminants on or in the ground covered,or to be covered by the building and anyland associated with the building.’

‘Resistance to moisture C2 The floors,walls and roof of the building shalladequately protect the building and peoplewho use the building from harmful effectscaused by:(a) ground moisture(c) interstitial and surface condensation.’

Gases from the groundInformation on methane and other gases isgiven in paragraphs 2.25 - 2.35.Gas control measures are given in 2.36 -2.38. For dwellings these should consist ofa gas resistant barrier across the wholebuilding footprint, above an extraction orventilation layer from which gases can bedispersed and vented to the atmosphere.

HydrocarbonsGround contaminated with hydrocarbonssuch as diesel or motor oils may alsogenerate harmful emissions (not specificallycovered by Approved Document C). Testingfor these is extremely difficult, therefore Glidevale recommend that in such cases aventilated sub-floor void is provided inaddition to a barrier membrane.

Gas entry routesinto buildings

B

Every building must be designed and

c

Every building must be designed and

c

Risk management techniques

Every building must be designed andc

Radon:

g

(*For

A

4

Gas entry routesinto buildings

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

61740 Glidevale Ground Floor Protection 12pp_Glidevale Ground Floor Protection 05/12/2017 06:35 Page 5

.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

T

Every building must be designed and

c

Every building must be designed and

c

Every building must be designed andc

Radon:

g

(*For

A

Building (Scotland) Regulations

Site preparation3.1 Every building must be designed andconstructed in such a way that there willnot be a threat to the building or the healthof people in or around the building due tothe presence of harmful or dangerous substances.

Harmful or dangerous substances Harmful or dangerous substances includedeposits of faecal or animal matter and anysubstance, or mixture of substances, whichis, or could become, corrosive, explosive,flammable, radioactive or toxic or whichproduces, or could produce, any gas likelyto have any such characteristic.

3.1.6 Risk management techniques There are a range of options for managingthe risk of land that is contaminated. Thiscan include removal or treatment of thecontaminant source or breaking the pathway by which contaminants can present a risk to receptors:

Sealing means that an imperforate barrier islaid between the contaminant and thebuilding and sealed at the joints, around theedges and at the service entries.

Detailed guidance is given in BRE /Environment Agency Report BR 414 Protective measures for housing on gas-contaminated land.

Radon protectionAll new buildings, extensions and conversions in areas where there may be elevated radon emissions may need to incorporate precautions.

3.2 Every building must be designed andconstructed in such a way that there willnot be a threat to the health of people in oraround the building due to the emission andcontainment of radon gas.

Radon protective measures should be provided in accordance with the guidancecontained in BRE publications BR 211Radon: guidance on protective measuresfor new dwellings, and BR 376 Radon:guidance on protective measures for newdwellings in Scotland.

Additional guidance on the installation ofRadon protection measures in dwellings isavailable in two BRE Good Building Guides,GG73, “Radon protection for new domesticextensions and conservatories with solidconcrete ground floors”, and GG74, “Radonprotection for new dwellings”.

Moisture from the ground3.4 Every building must be designed andconstructed in such a way that there willnot be a threat to the building or the healthof the occupants as a result of moisturepenetration from the ground.

CIRIA C665 and NHBC Traffic Lights Protect GDB10 PLUS complies with theNHBC Traffic Lights* and CIRIA C665, wheninstalled as prescribed in BRE 414. (*ForAmber 2 or worse the membrane should always be fitted by a qualified installer orspecialist contractor).

Additional guidance on the installation ofRadon protection measures in dwellings isavailable in two BRE Good Building Guides,GG73, Radon protection for new domesticextensions and conservatories with solidconcrete ground floors and GG74, Radonprotection for new dwellings.

Building Regulations (Northern Ireland) Protection against ground contaminantsand moisture are specific Requirements ofthe Building Regulations Part C for Northern Ireland. The relevant Requirementsare:

‘Preparation of site and resistance to dangerous and harmful substances C26(1) The site of a building and the groundadjacent to it shall be prepared and treated,and measures shall be taken, so as to prevent, as far as reasonably practicable,any harmful effect on the building or thehealth or safety of the occupants causedby:b) dangerous or harmful substances.

2) Without prejudice to the generality ofparagraph (1) measures shall be taken toprevent or limit the ingress of radon fromthe ground into any dwelling.’

‘Resistance to ground moisture andweather C28 Every wall, floor and roof shallbe constructed so as to prevent any harmful effect on the building or the healthof the occupants caused by the passage ofmoisture to any part of the building from:a) the ground.’

Building Regulations Republic of IrelandProtection against ground contaminantsand moisture are specific Requirements ofthe Building Regulations Part C.The relevant Requirements are:

‘Dangerous Substances C3 Reasonableprecautions shall be taken to avoid dangerto health and safety caused by substances(including contaminants) found on or in theground to be covered by a building.’

‘Resistance to weather and groundmoisture C4 The floors, walls and roof of abuilding shall be so designed and constructed as to prevent the passage ofmoisture to the inside of the building ordamage to the fabric of the building.’

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

61740 Glidevale Ground Floor Protection 12pp_Glidevale Ground Floor Protection 05/12/2017 06:35 Page 6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .BARRIER MEMBRANES

.

GROUND FLOOR PROTECTION, GAS AND DAMP BARRIERS

PROTECT RADON 1200 DAMP PROOFMEMBRANE

Radon 1200 is satisfactory for use inconcrete floors which are not subjected to ahydrostatic pressure, in accordance with therelevant clauses of CP 102: 1973.

The membrane can be installed either as anoversite membrane, situated between ablinded hard core bed and the base concrete,or as a sandwich membrane in base concreteor between the base concrete and thescreed.

The membrane meets the requirements foruse as a gas control membrane againstradon or on gas-contaminated land generallyin accordance with the recommendationspublished by the Building ResearchEstablishment (BRE 211) and the nationalBuilding Regulations. The membranes maybe used with both unreinforced andreinforced concrete ground supported slabs.The use of reinforced concrete slabs is onlynecessary where, in the opinion of thedesigner, there is a risk of settlement andcracking of the slab occurring.

Composition, sizes1200 gauge extruded polyethylene withnominal characteristics of:

Roll weight: 27.6kgStandard roll length: 25mStandard roll width: 4m

Performance and test methods: Protect GDB10 PLUS

)

PROTECT GDB10 PLUS GAS & DAMPBARRIER MEMBRANE

Protect GDB10 PLUS is a universal barriermembrane for protection of new buildingsagainst gas and damp penetration from theground.

Used as an oversite membrane below floorslabs or suspended floors, in conjunctionwith the Glidevale Cavity and Slab EdgeProtection System, it provides a completesolution when installed in accordance withBRE Report BR 414.

● Excellent resistance to harmful soil gasesand damp penetration.

● Enables Building Regulations Part C tobe met by reference to ApprovedDocument C, see Technical requirements.

● No additional damp-proof membranerequired.

● Tough and durable, excellent tensilestrength, puncture and tear resistance.

● Easily installed: easy to cut, lightweightand clean to handle.

● Each roll supplied with fixing instructions.

● Full range of accessories and underfloorventilation products.

Composition, sizesMulti-layer reinforced polyethylenemembrane with an integral continuousaluminium foil.

Roll length: 40mRoll width: 3.0mBasis weight: 144g/m2

Roll weight: 19.6kg

Cavity Barrier andcombined Cavity Tray

S

Protect GDB10PLUS Membrane

Slab EdgeProtection Tray

Three Glidevale barrier membranes areavailable:

● Protect GDB10 PLUS provides protectionagainst methane, carbon dioxide andradon as well as damp.

● Protect Radon 1200 is also for useagainst radon and damp.

● Self adhesive gas resistant dpc /membrane is used for sealing aroundcolumns, concrete slabs etc.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B

Performance and test methods: Protect GDB10 PLUS MD (along roll) CD (across roll)

Nail tear strength (N) to BS EN 12310-1 modified 474 464

Tensile strength (N/50mm) to BS EN 12311-1 modified 680 415

Elongation (%) to BS EN 12311-1 modified 26 18

CBR Puncture Resistance (N) to BS EN ISO 12236 1258

Methane permeability based on BS ISO 15105-1 < 0.3ml/m2.24hrs@1atm

Carbon dioxide (CO2) permeability to BS EN 374-3 < 1.0 µg/cm2/min

Radon permeability 4.2 x 10-12m2/s

Radon transmittance 21 x 10-9m/s

Water penetration resistance to BS EN 1928, Method A modified Pass Class W1

Three Glidevale barrier membranes areavailable:

● Protect GDB10 PLUS provides protectionagainst methane, carbon dioxide andradon as well as damp. Suitable for usein Amber 2 areas.

● Protect Radon 1200 is also for useagainst radon and damp.

● Self-adhesive gas resistant dpc/membrane is used for sealing aroundcolumns, concrete slabs etc.

PROTECT GDB10 PLUS GAS & DAMP BARRIER MEMBRANE

Protect GDB10 PLUS is a universal barriermembrane for protection of new buildingsagainst gas and damp penetration from theground.

Used as an oversite membrane below floorslabs or suspended floors, in conjunctionwith the Glidevale Cavity and Slab EdgeProtection System, it provides a completesolution when installed in accordance withBRE Report BR 414.

● Complies with BS 8485:2015.● Excellent resistance to harmful soil gases

and damp protection.● Approved for use in Amber 2 applications.● Enables Building Regulations Part C to

be met by reference to Approved Document C, see Technical Requirements.

● No additional damp-proof membrane required.

● Tough and durable, excellent tensile strength, puncture and tear resistance.

● Easily installed: easy to cut, lightweight and clean to handle.

● Each roll supplied with fixing instructions.● Full range of accessories and underfloor

ventilation products.

Composition, sizesMulti-layered reinforced polyethylene membrane with an integral continuous aluminium foil.

Roll length: 40mRoll widths: 3m, 1m, 0.6m and 0.45m.Basis weight: 150g/m2

Roll weights: 3m: 18.9kg, 1m: 6.3kg,0.6m: 3.78kg and 0.45m: 2.5kg

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

BARRIER MEMBRANES

6

Cavity Barrier andcombined Cavity Tray

Protect GDB10PLUS Membrane

Slab EdgeProtection Tray

61740 Glidevale Ground Floor Protection 12pp_Glidevale Ground Floor Protection 05/12/2017 06:35 Page 7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B

Shown above (from topto bottom) 150mm,300mm and 600mmwide gas resistantmembrane.

P

SELF ADHESIVE GAS RESISTANTDPC / MEMBRANE

An adhesive backed gas resistantmembrane specifically designed for usewith Protect GDB10 PLUS gas and dampbarrier for sealing around columns,concrete slabs, etc.

The very high initial adhesion allows easyand instant lamination to a wide variety ofsubstrates including concrete, steel andmasonry.

Features

● Excellent resistance to harmful soil gasesand damp penetration

● High adhesive properties

● Versatile, used to form column cloaks

● Easily shaped to form a gas proof cavitybarrier

● Tough and durable

● Excellent tensile strength

● Puncture and tear resistant

Composition, sizesTriple ply construction including a toughpolywoven core layer with a bright highpurity aluminium foil which is bonded with a0.8mm pressure sensitive modified acrylictransfer tape with siliconised paper releaseliner.

Weight: 309g/m2

Roll sizes: 20m roll lengths in 150mm,300mm, 450mm and 600mm widths

ApplicationThe surface to be bonded must be clean, iefree of dust, release agents, processing oilsand grease. The temperature of theapplication should not be below the dewpoint of the surrounding air. The warmer thetape the better the immediate adhesion willbe. A dedicated primer is also available forfibrous or very porous applications.

Roll sizes: 20m roll lengths in 150mm,300mm and 600mm widths.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

61740 Glidevale Ground Floor Protection 12pp_Glidevale Ground Floor Protection 05/12/2017 06:35 Page 8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PREFORMED ACCESSORIES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

GROUND FLOOR PROTECTION, GAS AND DAMP BARRIERS

A comprehensive range of preformedaccessories is available for use withmembranes to maintain protection at wallcavities, corners, pipe and service entriesetc.

Design of components removes the need toform difficult shapes on site, giving asimpler and more reliable installation.

Radon Cavity Barrier and combined Cavity TrayOne size fits wall cavities from 50 to 100mmwide.Also suits 150mm deep suspended floors.Other sizes available to special order.Sparked finish surface promotes mortaradhesion and prevents the creation of slipplanes in masonry.Supplied in 25m or 50m rolls.

. . . . . . . . . . . . . . . . . . . .

Self adhesive Periscope CloakMaintains continuity by providing apreformed cloak to seal around the verticalsection of a periscope vent where such avent passes through a cavity barrier.

RS Radon SumpInstalled within fill material in underfloorvoids to collect radon gas and vent it byconvection through a vertical pipe.

The Periscope Cloak is supplied flat; folded foruse on site as shown

Jointing tapeGas Jointing Tape and Joint ProtectionTape for making joints in membranes andbetween membranes and othercomponents.Available in roll widths of 12, 30 and 50mm.

Where extra high adhesion is required,Transfer tape with a pressure-sensitivemodified acrylic adhesive is available foruse as a general mounting tape.

RS22 Slab Edge Universal CornerPreformed unit which is reversible forexternal or internal corners.For slab thicknesses: RS22/100 for 100mm,RS22/150 for 150mm.

RSE Radon Slab Edge Protection TrayDesigned to accommodate slabthicknesses of 100 or 150mm.Supplied in 25m or 50m rolls.Other sizes available to special order.

Cavity Barrier Universal CornerPreformed unit which is reversible forexternal or internal corners.150mm deep as standard. Other sizesavailable to special order.

RPS1 Universal Pipe SealSeals around service pipes which penetrate the membrane.To fit pipe/sleeve diameters as follows:RPS1/110: 100 to 120mm.RPS1/130: 130 to 140mm.RPS1/160: 150 to 160mm.

Bespoke fabrications available to specialorder.

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

61740 Glidevale Ground Floor Protection 12pp_Glidevale Ground Floor Protection 05/12/2017 06:35 Page 9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .GROUND FLOOR PROTECTION, GAS AND DAMP BARRIERS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .UNDERFLOOR and CAVITY WALL VENTS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The Glidevale range of underfloor andcavity wall ventilation products enable theregulatory requirements for ventilation to bemet.

● Adaptable to a wide range of situationsincluding different floor depths andremote voids.

● Also provides protection against the entryof driving rain, birds, rodents and largeinsects.

MV250 AirbrickVentilation area 6000mm2

Standard brick face dimensions.Can be stacked in multiples.Driving rain resistant.Can be used with MV251 Periscope andMV253 Vent Pipe Adaptor.Colours: terracotta, buff, anthracite.

MV251 PeriscopeProvides ventilation beneath suspendedfloors.Vertical adjustment for 3-4 brick courses.Suitable for cavity widths from 50 to 100mm.Can be used with MV250 Airbrick, MV254Vertical Sleeve and MV253 Vent PipeAdaptor.

MV253 Vent Pipe AdaptorEnables remote voids to be ventilated viaconnection to 100mm internal diameterpipe.Can be attached to MV250 Airbrick andMV251 Periscope.

MV254 Vertical SleeveFits between two halves of MV251Periscope to increase overall depthadjustment up to 5-6 brick courses.Modular design allows additional units tobe added for even greater depths.

HT2 Airbrick Cavity TrayInstalled above an airbrick to protect thewall cavity against damp penetration inaccordance with BS 8215: 1991.Short length for ease of installation whilstproviding 100mm extension on each side ofairbrick.

MV650 WeepventCavity wall ventilator and weep unit in oneinnovative product.Fits into a single perpend joint.Ventilation area 220mm2.Driving rain resistant and protects againstlarge insect ingress.Colours: terracotta, buff, grey.Can be used in brickwork, blockwork,timber-framed and rendered walls.

InstallationUnderfloor vent spacingLocate underfloor vents on opposite sidesof the building to achieve the most effectivemix and distribution of air flow.

Installed at 4.0m centres they will provide1500mm2 ventilation area per metre ofexternal wall to comply with BuildingRegulations Approved Document C.

However we recommend spacing at 2.0mcentres to avoid the risk of stagnant airpockets and consequent risk ofaccumulation of gases.

Cavity traysBS 8215: 1991 recommends use of cavitytrays above any point where a wall cavity isbridged. Glidevale HT2 or HTR cavity trayswith stopends and weepvents should beused above MV250 Airbricks and MV251Periscopes.

WeepventsWeepvents should be installed on all cavitytrays at 450mm centres.

For timber frame wall cavity ventilation,install at a horizontal spacing of 450mmcentres, at low and high level and aboveand below fire stops in a staggered layout.

9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

61740 Glidevale Ground Floor Protection 12pp_Glidevale Ground Floor Protection 05/12/2017 06:35 Page 10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .APPLICATION DETAILS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Exposed edge protected byGlidevale 50mm foil-facedJoint Protection Tape

Protect GDB10 PLUSmembrane

Glidevale 50mm double-sided Gas Jointing Tape

Glidevale 50mm foil-facedJoint Protection Tape

Glidevale polypropylene Slab Edge Protection Tray

Alternatively the joint can beformed using 150mm gasresistant tape

Service pipe penetration of membrane

Wall ventilation

MV650 used as weep or ventilator

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .GROUND FLOOR PROTECTION, GAS AND DAMP BARRIERS

.

Slab and edge protection

Radon ventilation

Slab edge and cavity wall

Protect GDB10 PLUS membrane jointing

Blinded substrate

12 x 2mm butyl strip

Glidevale 50mm foil-facedJoint Protection Tape

Jubilee clamp

Glidevale RPS1Universal Pipe Seal

Ventilation of underfloor void with porous fill

Radon laden air escapingnaturally by convection

Glidevale RPS1 Universal PipeSeal

Protect GDB10PLUS membrane

RS Radon Sump

Porous fillmaterial

12 x 2mm butyl strip

Glidevale MV650 Universal WeepVent at maximum 450mm centres

Glidevale polypropylene Cavity Barrier and combined Cavity Tray

Glidevale 50mm double-sidedGas Jointing Tape

10 1

. . . . . . . . . . . . . . . . . . . . . . . . . . . .A

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

E

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G

Mechanical clamp or tie

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

61740 Glidevale Ground Floor Protection 12pp_Glidevale Ground Floor Protection 05/12/2017 06:35 Page 11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

E

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G

. . . . . . . . . . . . . . . . . . . . . . . . . . . .A

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

E

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specification clausesGas/damp protectionProvide combined gasand damp protection toground floors to complywith Building RegulationsApproved Document C bymeans of :Protect GDB10 PLUSmembrane (methane,carbon dioxide, radon) /Glidevale Radon Shieldmembrane (radon only)Glidevale Edge and CavityProtection SystemGlidevale Underfloor andcavity wall vents allsupplied by Glidevale,2 Brooklands Road, Sale,Cheshire, M33 3SS.Tel: 0161-905 5700,Fax: 0161-905 2085, Email: [email protected].

Protect GDB10 PLUSmembrane / ProtectRadon Shield membraneLay membrane directly ona suitable blindedsubstrate. Overlap jointsby a minimum of 150mmand seal using Glidevale 50mm widedouble-sided Gas JointingTape. Protect theexposed edge of the jointby taping to theunderlying layer using Glidevale 50mm wide foil-faced Joint ProtectionTape. Alternatively thejoint can be formedusing 150mm gasresistant tape. Sleeve service pipepenetrations usingGlidevale RPS1 pipeseals, lapped and sealedto the membrane asabove.

Glidevale Edge andCavity Protection SystemEnsure continuity of gasand damp barrier at allexternal walls by installingGlidevale Slab EdgeProtection Tray sealed tothe membrane usingGlidevale 50mm widedouble-sided Gas JointingTape. Alternatively thejoint can be formed using150mm gas resistanttape. Provide continuous gasand damp protection inthe wall cavity by installing Glidevale polypropyleneCavity Barrier andcombined Cavity Tray.Seal Glidevale Slab EdgeProtection Tray to the topof the Cavity Barrier trayusing Glidevale 12mmwide double-sided GasJointing Tape. Site Glidevale MV650 universalweep ventilators directlyon the Cavity Barrier trayin the external masonryleaf at maximum 450mmcentres around thebuilding perimeter.

Glidevale Underfloor andcavity wall ventsProvide ventilation tounderfloor voids bymeans of GlidevaleUnderfloor and cavity wallvents installed inaccordance withmanufacturer’sinstructions.

Glidevale Radon SumpInstall Glidevale RadonSump within porousunderfloor fill material withvertical pipe venting inaccordance withmanufacturer’srecommendations.

MV251 Periscope

MV250 Airbrick

Membrane

Solid floor with ventilation

Timber frame detail

Underfloor ventilation

S

MV250 Airbrick

MV650 Universal Weep Vent

MV650 Universal Weep Vent

MV650 Universal Weep Vent

Glidevale HT2 Cavity Tray

Glidevale HT2 Cavity Tray

MV251 Periscope

RSE Radon Slab Edge Protection Tray

RSE Radon Slab Edge Protection Tray

Radon/damp proof membrane

Glidevale polypropylene Cavity Barrier and combined Cavity Tray

Membrane

RSE Radon Slab Edge Protection Tray

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

61740 Glidevale Ground Floor Protection 12pp_Glidevale Ground Floor Protection 05/12/2017 06:35 Page 12

Environment / Operational InformationAs part of our commitment to minimisingour impact on the environment, and tocontinuously improve in our methods ofoperation, Glidevale is accredited toISO14001 Environmental Management,OHSAS 18001 Health and SafetyManagement and ISO 9001 QualityManagement Systems.

Technical supportGlidevale offers a full technical advisory andestimating service. Contact our TechnicalServices Department on 0161 905 5700 forfurther information or to request a completeschedule and quotation covering allproducts required.

T Fax: 0161 905 2085E Web: www.glidevale.com

G

Company Registration No; 3944123

.

Other products from Glidevale

Cavity trays and preformed DPCs

Tile and slate ventilators

Abutment ventilators

Eaves and low level ventilation systems

Loft access traps/ladder

(13.9) U

910611 November 2017 4689

GLIDEVALE2 Brooklands Road, Sale, Cheshire M33 3SS Tel: 0161 905 5700 Fax: 0161 905 2085Email: [email protected] Web: www.glidevale.com

Glidevale maintains a policy of continuous development and reserves the right to amend product specifications without notice.

A division of Building Product Design Ltd. Company Registration No; 3944123

i PSV® whole-house ventilation system

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Stockist’s stamp

ISO 9001 OHSAS 18001

Environment / operational information

61740 Glidevale Ground Floor Protection 12pp_Glidevale Ground Floor Protection 05/12/2017 06:34 Page 1