GigaLine® Fiber optic cabling systemsfor DataCenter · Office · Industry
The Quality Connection
www.leoni-infrastructure-datacom.com
2
Issue: March 2014 © LEONI Kerpen GmbHThe contents of this catalog are protected by copyright. All rights are reserved.
All necessary planning documentation available online:www.leoni-infrastructure-datacom.comTechnical changes, errors and omissions without prior notice.
Safety instructionsCables are to be used for the designated applications only. .
WaiverThe specifications in this document are provided according to our best cur-rent knowledge. However, these specifications may not be considered an assurance of specific properties or suitability for specific purposes of the respective products. Such indications may not be interpreted as a misguid-ance for the violation of property rights or as an assurance of a correspond-ing license. The suitability of each product for any particular purpose must be checked beforehand with our specialists. Our policy is to continuously improve our materials and products. Therefore, we reserve the right to offer alternatives consistent with our manufacturing programme at the time of enquiry. All information concerning material properties, fire performance, construc-tion, electrical and technical data, prices etc. reflects our current level of knowledge and is provided without obligation. Dimensions and weights are guideline values. All specifications can be changed at any time without prior notification.
General conditions of sale and deliveryWe refer to the currently valid General conditions of sale and delivery which can be obtained from the respective companies.
GigaLine® Cabling systemsWhenever broadband data transmission in combination
with large transmission lengths in LAN or MAN is
required, fiber optic cable and connection technology
is the best choice.
With GigaLine® fiber optic cables and GigaLine® FO
connectivity, LEONI offers high-speed data motorways
for backbone networks.
LEONI products and solutions are used wherever the
highest reliability, quality and durability are a must
– even in harsh and unfavourable conditions.
Welcome to the mega store for cable and system solutions
www.leoni-infrastructure-datacom.com
3
pageThe LEONI Group 4High-quality industrial cables and conductors 5Great brands, great service 6Green Technology 8
Technologies – investment in sustainable security 8
GigaLine® product range
GigaLine® FO data cables
• Introduction
• GigaLine® FO data cables
• GigaLine® „fire secured“ FO data cables
12
14
25
33
GigaLine® FO connectivity
• Introduction – GigaLine® FO cabling systems
• GigaLine® Trunk and splice boxes
• GigaLine® Compact – fiber optic distribution system
• GigaLine® Office and floor distributors
• GigaLine® Fiber-To-The-Desk (FTTD) wall outlets
42
44
46
54
60
64
GigaLine® FO patch cords / trunk cables
• GigaLine® Patch cord
• GigaLine® Trunk – pre-assembled trunk cables
70
72
76
GigaLine® DataCenter links 86
Acceptance measurement for GigaLine® cabling systems 92
Field of applications
Office 94
DataCenter 96
Index 102
LEONI news 103
www.leoni-infrastructure-datacom.com
4
The LEONI Group Cable expertise for the most varied industrial markets
Your markets – our strength.
As diverse as our product and service range are the markets and
sectors LEONI is supplying. We focus our activities on customers
in the fields of Automotive & Commercial Vehicles, Industry &
Healthcare, Communication & Infrastructure, Electrical Appliances
and Conductors & Copper Solutions.
We are among the leading European suppliers in the Communi-
cation & Infrastructure market to which at LEONI as a cable
manufacturer also belong activities in the fields of Infrastructure
& Data Communications, Industrial Plant Projects, Solar & Wind-
power, Energy & Telecommunications, Irradiation Cross-Linking
and Traffic Engineering. Our customers benefit worldwide from
innovative as well as reliable and long-lasting products of high
quality. LEONI – we create the best connection for your future.
For further information www.leoni.com
LEONI's core markets
LEONI is a leading supplier of cable systems and related
services for the automotive industry and various other in-
dustrial sectors.
Our group of companies employs more than 61,000 people in
33 countries. Corporate vision, highest quality and innovative
power have made us one of the leading cable manufacturers in
Europe. LEONI develops and produces technically sophisticated
products ranging from wire and optical fibers to cables through
to complete cable systems and also offers the related services.
Moreover, the product portfolio comprises strands, standardised
cables, hybrid cables, glass fiber as well as special cables, cable
harnesses, wiring systems components and fully assembled
systems for applications in various industrial markets.
Automotive &
Commercial Vehicles
Communication &
Infrastructure
Industry &
HealthcareElectrical
AppliancesConductors
& Copper Solutions
Products and services portfolio at a glance
Service
Optical cablesHybrid cablesCopper cables
Cable systems / Wiring systems
Relay and safety systemsSensorsCable harnesses
ConnectorsOptical fibersWires & strands
Engi
neer
ing
www.leoni-infrastructure-datacom.com
5
Business Unit Infrastructure & Datacom
Future-proof complete solutions For building infrastructure cabling in energy and data technology
Data networks of the future
In order to do justice to the future exchange of data, we already
offer cabling systems that are structured and a safe investment.
Bigger volumes of data, global linking and easily scalable data
networks will shape the future. Requirements that we are con-
fronting with innovative, safe and sustainable high-grade glass
fibre and copper cables and modular cabling and connection
systems.
Cost-efficiency in every stage of the project
Our service package BETAsolution® provides on-site consulting
from planning, projecting to logistics and installation all the way
to project acceptance. Rising costs and time pressures combined
with ever-higher requirements for materials and sustainability
call for increasingly efficient project management. Major projects
like the Gotthard Base Tunnel in Switzerland benefit not only
from the comprehensive range but also from our knowledge and
skill. BETAsolution® reduces interfaces and considerably in-
creases project efficiency. Specialists ensure comprehensive com-
plete solutions worldwide and thus create a true competitive
edge for our clients.
Our long-standing tradition of producing innovative cable
products is our pledge to constant peak performance. Starting
with our competence centres in Däniken (Switzerland) and
Stolberg (Germany), it is necessary to always plan ahead in the
fields of development and research for our products.
Connecting tomorrow’s world today already then also means
looking ahead. Constant advancement and research is our claim
in this. We see complexity as a challenge. Being innovative to us
means moving forward and simultaneously trusting in our com-
petencies. We create connections that link people safely, quickly
and convincingly – today and tomorrow.
For further information www.leoni-infrastructure-datacom.com
The demands on traffic, data and infrastructure networks will
rise in the future. Larger data bandwidths, global networking
and increasing individual traffic are associated with constraints
on resources, cost pressures and environmental protection.
Providing efficient, sustainable and safe power supply as well
as energy and data distribution in buildings is the demand of
tomorrow. LEONI’s business unit Infrastructure & Datacom has
realised these insights for quite some time and produces the
quality connections of the future today already. Together with
the Energy & Communication business unit, LEONI offers future-
proof complete solutions for building infrastructure cabling in
energy and data technology.
The innovative energy supply of tomorrow
The exponentially increasing energy consumption is rising along
with the growing urbanisation and mobility and also determines
the trends in the energy industry. We try to face these insights
successfully today already. With our products and services for
energy production and distribution we want to make an active
contribution to the prevention of today’s energy loss in the
future. Energy and communication will inevitably merge in the
future. With the focus on intelligent energy grids we contribute
to sparing the environment, resources and costs.
For maximum safety in building cabling
As a leading supplier in the market of structured building cabling,
we combine competencies – in energy and communications
networks, public buildings, civil engineering, offices, data centres
and industry. While increasingly complex applications confront
the infrastructure with new challenges, we are obligated to pro-
vide maximum safety everywhere. Flexible system and connection
solutions also make it possible to be prepared for tomorrow’s
connections today.
www.leoni-infrastructure-datacom.com
6
Great brands, great service Put your trust in the best partner to suit your needs
Investors, integrators, designers, installers and the trade –
you can now get all your cabling, connectivity and complete
cabling solutions from a single source – from copper and
fibre optic technology to halogen-free energy cables, with
or without circuit integrity. Constant safety, environmental
compatibility and energy efficiency innovations complete
the list of customer benefits.
Global presence, consulting on site during all stages of a
project as well as extensive experience gained in numerous
projects and far-reaching synergies inside and outside
the LEONI Group makes us international one of the most
accredited partners in the field of building and infrastructure
cabling.
Our commitment to developing innovative prod-ucts proves our dedication to our responsibility. In conjunction with our consulting services,we create trust and help our partners accomplish maximum safety for people and infrastructurein their projects.
Infrastructure –for maximum safety in cabling for buildings
Our products set the standard worldwide – in buildings, in under-
ground construction and in traffic infrastructure. Our cables
based on our proprietary patented design and production pro-
cesses ensure maximum safety and performance. The halogen-
free, fire-resistant insulation materials meet all the relevant stand-
ards while their extended service life also presents a com-
pelling advantage. Whether as laying systems or highly complex
network systems, our full infrastructure range convinces cust-
omers worldwide.
■■ BETAflam® according to the VDE standard Safety and installation cables
■■ BETAflam® according to the British Standard BS 6387 Safety and installation cables
■■ BETAfixss® with circuit integrity under fire acc. to DIN 4102 Certified installation systems
www.leoni-infrastructure-datacom.com
7
Datacom – for maximum data integrity and bandwidth
From the very beginning of the digital data era, we have fulfilled
data networking requirements for both the short term and the
far future by using great innovation and a forward-looking ap-
proach. The profound expertise of the Infrastructure & Datacom
BU in copper and fibre optical cabling technologies represents a
powerful advantage in structured cabling systems for industry,
data centres and offices – the sustainable copper and glass fibre
cables of our own production are among the safest and most
innovative products in the primary to tertiary cabling market.
■ MegaLine® Copper cables and passive system components
■ GigaLine® Fiber optical cables and passive system components
■ VarioLine® Modular system peripherals
Energy – the best connection for energy supply
With innovative and sustainable solutions we face the dynamic
development in the energy and communication market today
already. As one of the leading system and development partners
for energy production, transmission and distribution, we accept
the responsibility for safe and sustainable energy supply.
Our low- and medium-voltage power cables provide convincing
durability and resist even the most adverse conditions.
■ BETApower® Cable for power generation
■ BETAsolution® Cost-effectiveness at every phase of the project
www.leoni-infrastructure-datacom.com
8
Green Technology Our company aim is to combine innovation with sustainability.
Our vision is to create sustainable connections in technological
harmony with the natural resources. The cycle of nature gives
us the best model to emulate. It is our responsibility to learn
from nature and make use of it while conserving it and treating
it with care. The growing scarcity of the natural resources and
the increasing burden on the environment require a rethink
on all levels of society. For LEONI, sustainability is an integral
part of group policy. We are the first cable manufacturer in the
world to develop a holistic concept for “green technology”.
While trends like globalisation, mobility and urbanisation also
determine the markets, sustainability and global responsibility
are a central credo. To be considered the most innovative cable
manufacturer for environmentally friendly technologies – that
is our goal. At that, it is of vital interest to us to detect the needs
and requirements of tomorrow today and supply the markets
of the future with sustainable, future-proof solutions.
Green technology stands for the resource-conserving and low-
emission production of sustainable quality cables made with
low-pollution elements. We constantly work at optimising the
efficiency with which resources are used in the manufacturing
process by deploying energy-efficient machines or taking heat
recovery measures. More and more locations in our global pro-
duction network are environmentally certified according to the
ISO 14001 standard.
As a worldwide active and leading European supplier of wires,
optical fibres, cables and cable systems for communication and
infrastructure projects it is our responsibility to constantly op-
timise the sustainability and durability of our products, system
solutions and services and thus lower the environmental load.
We have to increase the amount of environmentally compatible
raw materials in our cable products as well as the recyclability
of processed materials or components and in doing so create
end products that are developed for the environmental stand-
ard of tomorrow today.
In conjunction with the ecological compatibility, future tech-
nologies are measured in terms of efficiency, service life, emis-
sion reduction and the conservation of natural resources. In-
novative cable products and systems, holistic solutions and
maximum performance in project management are the added
value which we offer to our customers and business partners.
These are also our cornerstones for strong connections into the
future.
REACh
EU Directive 2012/19/EU on waste electrical and
electronic equipment.
EU Directive 2011/65/EU for restriction of the use
of certain hazardous substances in electrical and
electronic equipment.
EU Regulation 1907/2006/EC (REACh) the chemical
regulation of the European Union.
There are various environmental directives in the European
Union (EU). Directive 2012/19/EU WEEE (Waste Electrical and
Electronic Equipment) regulates the disposal of electrical and
electronic equipment and components. The use of certain
hazardous materials in electrical and electronic devices is de-
fined by Directive 2011/65/EU RoHS 2 (Restriction of
Hazardous Substances). Chemicals and materials in general
are regulated by the law on chemical substances 1907/2006/
EC REACh (Registration, Evaluation, Authorisation and Re-
striction of Chemicals).
This means avoiding the following substances, among others:■■ Polybrominated diphenyl ether (PBDE)■■ Decabromodiphenyl ether (DecaBDE)■■ Perfluorooctane sulfonate (PFOS)■■ Pentabromodiphenyl ether (PentaBDE)■■ Octabromodiphenyl ether (OctaBDE)■■ Lead (Pb)■■ Mercury (Hg)■■ Cadmium (Cd)■■ Hexavalent chromium (Cr VI)■■ Polybrominated biphenyls (PBB)
Cables and conductors and their associated connectors are
only affected by Directive 2012/19/EU WEEE insofar as they are
an internal part of the listed equipment and components.
Cables and conductors have now been included in 2011/65/EU
RoHS 2 since 2013 for the first time (Category 11 or as an internal
component of the respective product). Fiber optic cables, power
cables (>250 V) and installed fixed cables e.g. in premises are
not concerned. The only permissible marking according to RoHS
2 is the CE marking, which is printed on the product package.
What does REACh mean?
REACh stands for Registration, Evaluation, Authorisation
and Restriction of Chemicals.
With REACh, the previous chemical law is basically
harmonised, simplified and valid in all EU Member States.
Under REACh, there is a so-called candidate list with
substance of very high concern (SVHC), which are subject
to obligatory information and should be substituted in
the long run. The list of candidate materials is updated
twice per year by the European Chemicals Agency (ECHA)
in Helsinki.
www.leoni-infrastructure-datacom.com
9
www.leoni-infrastructure-datacom.com
10
Technologies – investment in sustainable security Universal application with high system integrity
Our development and production centres LEONI Studer
(Switzerland) and LEONI Kerpen (Germany) are linked by
one thing in particular: competence. In extensive production
areas, we work with state-of-the-art methods and systems
in plastics processing, materials processing, extrusion
technology, electron beam cross-linking and the testing of
all products.
We use state-of-the-art production equipment in order to of-
fer our customers a maximum of safety and quality. New and
innovative plastics mixtures and cables are constantly being
developed in modern laboratories. The focus is on improved
insulating properties, higher temperature tolerances, longer
lifetimes, easy handling and better safety features. Our test
laboratories for flammability tests, HF technology and optical
measurement technology safeguard our quality standards and
promote innovation.
This is demonstrated by the large number of approvals and
certificates coming from well-known independent testing insti-
tutes worldwide.
www.leoni-infrastructure-datacom.com
11
■■ Halogen free
IEC 60754-1, EN 50267-2-1
■■ Degree of acidity of combustion gases
IEC 60754-2, EN 50267-2-2
■■ Smoke density
IEC 61034, EN 61034
■■ Flame retardancy
IEC 60332-1, EN 60332-1,
IEC + EN 60332-3-22/-24
■■ Circuit integrity
DIN VDE 0472-814, EN 50200,
VdS 3423, VDE 0482 BS 8434
■■ System integrity under fire
DIN 4102 part 12
■■ IT cabling systems Office
EN 50173-2, ISO/IEC 11801
■■ IT cabling systems Industry
EN 50173-3, ISO/IEC 24702
■■ IT cabling systems DataCenter
EN 50173-5, ISO/IEC 24764
Numerous national and international certificates confirm the company’s ability to provide innovative solutions.
www.leoni-infrastructure-datacom.com
12GigaLine®
GigaLine®
FO data cables
www.leoni-infrastructure-datacom.com
Office DataCenter Industry 13 GigaLine®
GigaLine® FO data cables page
GigaLine® FO data cables The fiber 14
GigaLine® FO data cables For LAN, WAN and SAN 17
GigaLine® fiber qualities 18
GigaLine® colour codes 19
GigaLine® type codes 20
Buffered fiber sheaths- and jacketing material for optical cables 21
Rodent protection for fiber optic cables 22
Pictograms 23
Handling and safety notices 24
GigaLine® FO data cables 25
o ■dc GigaLine® Indoor cable, duplex fig 8 KL-I-V(ZN)H 2 G/E 25
o ■dc■ i GigaLine® Indoor cable, duplex fig 0 KL-I-V(ZN)HH 2 G/E 26
o ■dc GigaLine® Indoor cable, Mini-Breakout KL-I-V(ZN)H n G/E 27
o ■dc■ i GigaLine® Breakout cable KL-I-V(ZN)HH n G/E 28
o ■dc■ i GigaLine® Universal cable, Mini-Breakout 800 N KL-U-VQ(ZN)H n G/E 29
o ■dc■ i GigaLine® Universal cable, central 2500 N KL-U-DQ(ZN)BH 1xn G/E 30
o ■dc■ i GigaLine® Universal cable, stranded 4000 N KL-U-DQ(ZN)BH nxm G/E 31
o ■dc■ i GigaLine® Universal cable, central 2500 N KL-U-DQ(ZN)H(SR)H 1xn G/E 32
LEONI „fire secured“ FO data cables 33
o ■dc■ i GigaLine® „fire secured“ universal cable, central with CIKL-U-D(ZN)BH 1xn G/ESystem integrity at least 90 min
34
o ■dc■ i GigaLine® „fire secured“ universal cable, central with CIKL-U-DQ(ZN)H(SR)H 1xn G/E System integrity at least 120 min
35
o ■ i GigaLine® Outdoor cable, central 1750 N KL-A-DQ(ZN)B2Y 1xn G/E 36
o ■ i GigaLine® Outdoor cable, stranded 4000 N KL-A-DQ(ZN)B2Y nxm G/E 37
o ■ i GigaLine® Outdoor cable, central 1750 N KL-A-DQ(ZN)2Y(SR)2Y 1xn G/E 38
o ■ i GigaLine® Outdoor cable, stranded 4000 N KL-A-DQ(ZN)2Y(SR)2Y nxm G/E 39
o ■ i GigaLine® Outdoor cable, stranded with sheath, 4000 N KL-A-DF (ZN)(L) 2Y nxm G/E 40
o ■ Office cables
dc■ DataCenter cables
i ■ Industrial cables
www.leoni-infrastructure-datacom.com
FO data cables14GigaLine®
Advantages of j-BendAble fibers■■ Greater reliability with higher packing density and installation
in constricted areas due to the low bending loss.■■ Low-risk patching in operation – the data transmission
remains stable despite significant bending.■■ The doubled tensile strength of the fibers minimises the risk
of a fiber tear in the patch field (200 kpsi in comparison to the
standard with 100 kpsi).■■ Maximum security for a mix and match with fibers of other
manufacturers due to the minimum transition damping.
Made in Germany ➔ j-BendAble fibers are manufactured by the LEONI subsidiary j-fiber GmbH in Jena – Germany's only specialists for fiber production. Learn more at www.j-fiber.de.
The right fiber
LEONI offers a comprehensive range of optical fibers tailored to the
various network requirements such as future-proof high-perfor-
mance transmission in DataCenters, reliable office networks and
stable industrial networks.
LEONI Multimode fibers
GigaLine® cables offer immediate, significant added value for
your operation. At no additional charge, the fiber optic cables
are now equipped with bend insensitive OM3 and OM4 fibers
(j-BendAble).
The steady increase in internet and intranet traffic, multi-
media applications and the establishment of central storage
networks (SAN or Storage Area Networks) in companies
have fundamentally changed the traffic and load distribu-
tion in networks. New media require new, more powerful
passive network infrastructures.
LEONI offers a future-proof cabling system with reserves
well beyond those stipulated in the standards.
Comparison of requirements
for Standard and GigaGrade
Fiber category OM1 G62.5/125 Fiber category OM1 G62.5/125
at 850 nm at 1,300 nm
Standard OM1OM1e LEONI
GigaGrade G62.5/125 MStandard OM1
OM1e LEONI GigaGrade G62.5/125 M
Attenuation 3.5 dB/km 3.0 dB/km 1.5 dB/km 0.8 dB/km
Modal bandwidth 200 MHz x km 250 MHz x km 500 MHz x km 800 MHz x km
Gigabit Ethernet segment length 275 m 500 m 550 m 1,000 m
10 Gigabit Ethernet segment length 32 m 65 m 300 m 450 m
Comparison of requirements
for Standard and GigaGrade
Fiber category OM2 G50/125 Fiber category OM2 G50/125
at 850 nm at 1,300 nm
Standard OM2OM2 LEONI
Standard GigaGrade G50/125
OM2e LEONI High Performance
GigaGrade G50/125Standard OM2
OM2 LEONI Standard
GigaGrade G50/125
OM2e LEONI High Performance
GigaGrade G50/125
Attenuation 3.5 dB/km 2.7 dB/km 2.5 dB/km 1.5 dB/km 0.8 dB/km 0.7 dB/km
Modal bandwidth 500 MHz x km 500 MHz x km 600 MHz x km 500 MHz x km 500 MHz x km 1200 MHz x km
Gigabit Ethernet segment length
550 m 550 m 750 m 550 m 550 m 2,000 m
10 Gigabit Ethernet segment length
82 m 82 m 150 m 300 m 300 m 700 m
GigaLine® FO data cables The fiber
www.leoni-infrastructure-datacom.com
Office DataCenter Industry FO data cables 15 GigaLine®
GigaGrade GigaGrade j-BendAble j-BendAble
OM1 OM2e OM3 OM4
LAN Datacenter
LAN Office
LAN Industry
j-BendAble OM4 future-proof without compromise
The j-BendAble OM4 multimode fiber fulfils the requirements of the OM4
standard for the serial transmission of 10 Gbit/s with an EMB of 4,700 MHz
x km over 550 m. The fiber has been optimised for applications with 850
nm VCSEL and offers the possibility of use at higher transmission rates such
as 40 Gbit/s or 100 Gbit/s going into the future. j-BendAble OM4 is the first
choice when it comes to speed and high data rates.
j-BendAble OM3 for 10 GbE networks
The sophisticated IT cabling in DataCenters and
office buildings, with a 10 Gigabit Ethernet-compa-
tible network, is based on the laser-optimised
j-BendAble OM3 fiber.
The optimum multimode fiber for every application:
Comparison of requirements
for Standard and OptiGrade
Fiber category OM3 G50/125 Fiber category OM3 G50/125
at 850 nm at 1,300 nm
Standard OM3OM3 LEONI
j-BendAble OM3Standard OM3
OM3 LEONIj-BendAble OM3
Attenuation 3.5 dB/km 2.5 dB/km 1.5 dB/km 0.7 dB/km
Modal bandwidth (overfilled launch) 1500 MHz x km 1,500 MHz x km 500 MHz x km 500 MHz x km
EMB (effective modal bandwidth) 2000 MHz x km 2,000 MHz x km n.a. n.a.
Gigabit Ethernet segment length 550 m 900 m 550 m 550 m
10 Gigabit Ethernet segment length 300 m 300 m 300 m 300 m
40/100 Gigabit Ethernet segment length 100 m 100 m 100 m 100 m
Comparison of requirements
for Standard and OptiGrade
Fiber category OM4 G50/125 Fiber category OM4 G50/125
at 850 nm at 1,300 nm
Standard OM4OM4 LEONI
j-BendAble OM4Standard OM4
OM4 LEONI j-BendAble OM4
Attenuation 2.5 dB/km 2.5 dB/km 1.5 dB/km 0.7 dB/km
Modal bandwidth (overfilled launch) 3,500 MHz x km 3,500 MHz x km 500 MHz x km 500 MHz x km
EMB (effective modal bandwidth) 4,700 MHz x km 4,700 MHz x km n.a. n.a.
Gigabit Ethernet segment length 550 m 1000 m 550 m 550 m
10 Gigabit Ethernet segment length 550 m 550 m 300 m (LX4) 300 m (LX4)
40/100 Gigabit Ethernet segment length 150 m 150 m 150 m 150 m
www.leoni-infrastructure-datacom.com
FO data cables16GigaLine®
j-LBL SMF flexible and compatible
The j-LBL SMF as per ITU-T G657.A is a high-performance field-
tested singlemode fiber for applications where the need for
compatibility with installed G.652.D networks is linked with
the requirement for improved bending characteristics for sturdy,
flexible and space-saving installations. The j-LBL SMF offers
maximum transmission performance with minimum attenua-
tion. Due to the reliably and permanently low attenuation at
1,383 nm, it can be used in the wavelength range from 1,360 nm
to 1,480 nm and the fiber is therefore also suitable for wave-
length multiplexing (DWDM and CWDM).
Comparison of requirements for Standard and j-LWP SMF+
Fiber category OS2 E9/125 (G.652.D)
at 1,310 nm at 1,550 nm
Standard OS2IEC 60793-2-50 B6_a
LEONI OS2 j-LWP SMF+
Standard OS2 IEC-60793-2 50-B1.3
LEONI OS2j-LWP SMF+
Attenuation 0.40 dB/km 0.36 dB/km 0.30 dB/km 0.23 dB/km
Attenuation at 1,383 nm < 0.40 dB/km 0.36 dB/km — —
1 Gigabit Ethernet segment length 5,000 m 5,000 m — —
10 Gigabit Ethernet segment length 10,000 m 10,000 m 22,250 m 40,000 m
40 Gigabit Ethernet segment length 10,000 m 10,000 m — —
Comparison of requirements for Standard and j-LBL SMF
Fiber category OS2 E9/125 low bend (G.657.A)
at 1,310 nm at 1,550 nm
Standard OS2IEC 60793-2-50 B6_a
LEONI OS2 low blendj-LBL SMF
Standard OS2 IEC 60793-2-50 B6_a
LEONI OS2 low blendj-LBL SMF
Attenuation 0.40 dB/km 0.36 dB/km 0.30 dB/km 0.23 dB/km
Attenuation at 1,383 nm < 0.40 dB/km 0.36 dB/km — —
1 Gigabit Ethernet segment length 5,000 m 5,000 m — —
10 Gigabit Ethernet segment length 10,000 m 10,000 m 22,250 m 40,000 m
40 Gigabit Ethernet segment length 10,000 m 10,000 m — —
100 Gigabit Ethernet segment length 10,000 / 40,000 m 10,000 / 40,000 m — —
Bending characteristics
The fiber exhibits excellent splicing properties thanks to its first-
rate uniformity and geometry. This means it is backwards com-
patible with already installed conventional singlemode fibers
(to ITU-T G.652.A+B) and low-water-peak singlemode fibers
(to ITU-T G.652 C+D).
Macro-bending losses, bending-induced attenuation
Values Unit
10 bends, radius 15 mm
1,550 nm ≤ 0,03 dB
1,652 nm ≤ 0,20 dB
1 bend, radius 10 mm
1,550 nm ≤ 0,30 dB
1,625 nm ≤ 1,00 dB
30
25
20
15
10
5
08 10 12 14 16 18 20
Bending diameter [mm]
Atte
nuat
ion
[dB]
Bending sensitivity at different wavelengths
1,310 nm1,550 nm1,625 nm
j-LWP SMF+ proven for long links
The low-water-peak singlemode fiber, j-LWP SMF+ as per ITU-T
G652.D or as per EN 50173 OS2, offers the best transmission per-
formance across the entire wavelength range from 1,260 nm to
1,625 nm. The fiber can be used in the wavelength ranges from
1,360 nm to 1,480 nm due to the reliably stable, low attenuation
at 1,383 nm. The j-LWP SMF+ is the preferred fiber wherever
maximum flexibility and long transmission lengths are required.
The use of WDM systems enables the full spectrum of fiber
capacity to be used – the prerequisite for flexible network plan-
ning. The fiber is fully compatible with installed singlemode
networks and enables network solutions with maximum perfor-
mance and flexibility.
The use of fiber optic data cables is especially
recommended if…■■ electromagnetic influences can occur■■ reliable potential isolation is required■■ a wide transmission bandwidth is required■■ low attenuation and therefore long transmission links
are required■■ crosstalk is not permitted■■ sparking (for areas subject to explosion hazards) is not permit-
ted■■ low weight and small dimensions are an advantage■■ increased security against interception is required
The product range at a glance:■■ Easy-to-assemble indoor cables with compact buffered fiber
technology for the patch and horizontal areas ■■ Universal cables for the backbone area indoors and outdoors ■■ Outdoor cables for LAN and WAN applications ■■ A wide range of designs such as outdoor cables with
– corrugated steel cladding
– steel band or steel wire armour
– additional lead covering as protection against chemicals
Gigabit, 10, 40 and 100 Gigabit Ethernet – strictest require-
ments for the quality of the fiber optic cabling.
The Ethernet protocol is the state of the art today in every area
of structured cabling. The corresponding standards for trans-
mission rates from 1 Gigabit/s to 100 Gigabit/s are defined
in IEEE 802.3ba.
The process used to manufacture the fibers has been optimised
in such a way that the profile of the multimode fiber is extre-
mely precise and disturbances in the fiber core are virtually eli-
minated. As differential mode delay does not occur under these
circumstances, mode-conditioning patch cords are not neces-
sary. For more than ten years now, the standard versions of fiber
optic cables with an improved gradient fiber G50/125 from the
category "OM2e" have provided bandwidth-length products of
600 MHz x km in the first window (850 nm) and 1,200 MHz x km
in the second window (1,300 nm) as well as Gigabit Ethernet
segment lengths of 750/2,000 m.
GigaLine® fiber optic cables with OM3 and OM4 fibers are
the optimum transmission medium, whatever the future
might hold.
Using the OM4 fibers with a laser bandwidth of 4,700 MHz x km
in the first window enables segment lengths of up to 550 m with
10 GbE, up to 300 m with 16 Gbit/s Fiberchannel or up to 150 m
with 40 and 100 GbE. This in turn enables cost-effective realisa-
tion of 10 GbE in the backbone of a building in nearly all cases.
Singlemode fibers must be used over long distances. The single-
mode fibers exceed the current requirements of the OS2 stan-
dard according to EN 50173-1 with attenuation of just 0.36 dB/
km at 1,310 nm and less than 0.22 db/km at 1,550 nm.
This means that the wavelength ranges around 1,383 nm can
also be used to increase the transmission capacity. The graph
shows the steadily dropping attenuation curve from 1,300 nm
to 1,625 nm for all singlemode fibers. These characteristics and
the PMD link design value of just 0.06 ps/ km guarantee large
reserves for faster transmission rates over very long distances
and WDM transmission systems.
The use of high-quality optical fibers is the key to manag-
ing future data volumes. GigaLine® Fiber optic data cables
are the first step in careful planning and implementation
of a passive network infrastructure.
www.leoni-infrastructure-datacom.com
Office DataCenter Industry FO data cables 17 GigaLine®
0.8
0.6
0.4
0.2
0
■ITU T 652B
■ITU T 652D
1250 1300 1350 1400 1450 1500 1550 1600 1650
Comparison SMF G652B / G652D
Wavelength [nm]
Atte
nuat
ion
[dB/
km]
GigaLine® FO data cables for LAN, WAN and SAN
www.leoni-infrastructure-datacom.com
FO data cables18GigaLine®
Fiber specificationsGigaGrade G62.5/125
j-BendAbleG50/125
GigaGrade G50/125
j-BendAble G50/125
j-BendAble G50/125
j-LWP SMF+E9...10/125
j-LWP SMF+E9...10/125
OptiGrade IEC 11801/EN 50173 OM1e OM2 OM2e OM3 OM4 OS2 OS2 low bend
IEC 60793-2 A1b A1a.1 A1a.1 A1a.2 A1a.3 B1.3 B6_a
ITU-T G.651 G.651 G.651 G.651 G.652.D G.657.A
Attenuation coefficient
dB/km at 850 nmdB/km at 1,300 nm
max. 3.0max. 0.7
max. 2.7max. 0.8
max. 2.5max. 0.7
max. 2.5max. 0.7
max. 2.5max. 0.7
dB/km at 1,310 nmdB/km at 1,383 nmdB/km at 1,550 nmdB/km at 1,625 nm
max. 0.36max. 0.40max. 0.23max. 0.23
max. 0.36max. 0.40max. 0.23max. 0.23
Bandwidth
MHz x km at 850 nm min. 250 min. 500 min. 600 min. 1,500 min. 3,500
MHz x km at 1,300 nm min. 800 min. 500 min. 1,200 min. 500 min. 500
Laser bandwidth
MHz x km at 850 nm min. 2,000 min. 4,700
Dispersion
at 1,310 nm max. 3.5 ps/nm x km max. 3.5 ps/nm x km
at 1,550 nm max. 18 ps/nm x km max. 18 ps/nm x km
Zero-dispersion wavelength 1,302≤ λ0 ≤1,322 1,302≤ λ0 ≤1,322
Zero-dispersion slope ≤0.092 ps/nm² x km ≤0.092 ps/nm² x km
PMD
Fiber < 0.1 ps/ km < 0.1 ps/ km
Link < 0.06 ps/ km < 0.06 ps/ km
Segment length with Gigabit Ethernet
at 850 nm (1000 BASE SX) 500 m 550 m 750 m 900 m 1,000 m
at 1,300 nm (1000 BASE LX) 1,000 m 550 m 2000 m 550 m 550 m 5,000 m 5,000 m
Segment length with 10 Gigabit Ethernet
at 850 nm (10G BASE-SR/SW) 65 m 82 m 150 m 300 m 550 m
at 1,300 nm (10G BASE-LX4) 450 m 300 m 700 m 300 m 300 m 10,000 m 10,000 m
at 1,550 nm (10G BASE-ER/EW) 40,000 m 40,000 m
Segment length with 40/100 Gigabit Ethernet
at 850 nm 40/100 GBASE-SR4/SR10 100 m 150 m
at 1,310 nm 40/100 GBASE-LR4 10,000 m 10,000 m
Numerical aperture
Nominal value 0.275 0.20 0.20 0.20 0.20 0.12 0.12
Refractive index (nominal value)
at 850 nm 1.497 1.483 1.483 1.483 1.483
at 1,300 nm 1.493 1.478 1.478 1.478 1.478
at 1,310 nm 1.467 1.467
at 1,550 nm 1.467 1.467
Proof load
100 kpsi ≥ 8.8 N
200 kpsi ≥ 17.6 N
100 kpsi ≥ 8.8 N
200 kpsi ≥ 17.6 N
200 kpsi ≥ 17.6 N
100 kpsi ≥ 8.8 N
100 kpsi ≥ 8.8 N
GigaLine® Fiber qualities
Wires (with stranded loose tubes)
Counting wire Red
Counting direction wire White
Other wires Green for G50/125
Bue for G62.5/125
Yellow for E9…10/125
Dummy elements Natural colours
The wires are consecutively counted, starting with the wire closest to the counting element. The dummy elements are not counted.
Fibers (in loose tubes) IEC 60304
Fiber no. Colour
1 Red
2 Green
3 Blue
4 Yellow
5 White
6 Grey
7 Brown
8 Violet
9 Turquoise
10 Black
11 Orange
12 Pink
13 Red/black
14 Green/black
15 Blue/black
16 Yellow/black
17 White/black
18 Grey/black
19 Brown/black
20 Violet/black
21 Turquoise/black
22 Natural/black
23 Orange/black
24 Pink/black
Mini-Breakout cable EIA/TIA 598C
Fiber no. Colour
1 Blue
2 Orange
3 Green
4 Brown
5 Grey
6 White
7 Red
8 Black
9 Yellow
10 Violet
11 Pink
12 Turquoise
www.leoni-infrastructure-datacom.com
Office DataCenter Industry FO data cables 19 GigaLine®
GigaLine® colour codes
www.leoni-infrastructure-datacom.com
FO data cables20GigaLine®
Cable type
Communication cable KL
Field of application
Indoor cable I
Universal cable U
Outdoor cable A
Breakout outdoor cable AT
Buffered fiber
Tight buffered loose tube V
Gel-filled loose tube D
Constructional composition
Swelling material, dry, longitudinally watertight Q
Water-blocking gel-filled, longitudinally watertight F
Non-metallic strain relief (ZN)
Steel strain relief (ZS)
Armour B
Corrugated steel tape (SR)
Cable sheath
PE Polyethylene sheath 2Y
Al + PE PE coated aluminium sheath (L)2Y
FRNC Halogen-free/flame-retardant sheath H
PVC Polyvinyl chloride sheath Y
PA Polyamide sheath 4Y
PUR Polyurethane sheath 11Y
Fiber number and fiber bundling
Number of fibers n
Number of loose tubes x number of fibers per tube nxm
Miscellaneous
n Field diameter/sheath diameter in… E9/125
n Core diameter/sheath diameter in… G50/125 or G62.5/125
Wavelength
850 nm B
1,300/1,310 nm F
1,550 nm H
Bandwidth/dispersion coefficient
in MHz · km with multimode fibers, dispersion parametersin ps/nm · km with singlemode fibers
GigaLine® 1 2 3 4 5 6 7 8 9
GigaLine® Type codes for easy assignment of the construction elements in fiber optic cables
Balancing application and fire prevention criteria
The sheath around the cable protects the optical fiber(s) from
the effects of mechanical, thermal and chemical action as
well as the ingress of moisture. In the event of a fire, however,
the cable sheath should prevent a fire from spreading and stop
toxic and corrosive gases from being produced.
The use of halogen-free, flame-retardant materials is advisable
in order to protect equipment and buildings but above all to
protect people. In harsh environments, PUR and PVC, in par-
ticular, are used owing to their high resistance to oils and their
abrasion resistance. PE is also commonly used as a sheath mate-
rial for outdoor applications.
However, it is often extremely difficult to meet all the require-
ments using just one sheath material. To best satisfy the pre-
vailing local operating conditions, LEONI offers a choice of dif-
ferent materials.
Please contact us if the criteria for your particular applica-
tion are not met by the cable constructions in this catalogue.
Additional requirements can often be met through customised
measures when making the sheath (e.g. aluminium tape or spe-
cial mixtures of sheaths).
Cable sheath material
Material characteristics FRNC PUR PVC PE
Resistance to aging + + + +
Halogen-free + + – – +
Flame retardancy + ● + – –/●
Elasticity – + ● –
Abrasion resistance – ++ + +/–
Low smoke gas generation ++ ● – – –/●
Low emission of corrosive gases ++ ● – – +/●
Low smoke gas toxicity ++ ● – – +/●
No toxicological risk ++ ● – +/●
General resistance to FRNC PUR PVC PE
UV light 1) 1) 1) 1)
Water absorption – – + +
Gas diffusion – 2) – ●
Fuels – + +/– +
Petroleum/lubricants – ++ ● +
Organic solvents – + 3) – + 4)
Alcohol – – + +
Oxidants – – + –
Acids + – – + ++
Alkaline solutions + – – + +
Saline solutions + – + +
++ excellent+ good● depends on recipe– weak– – inadequate
1) UV resistance can be increased by adding black colour pigments or UV stabilisers
2) Permeation depends on the type of gas, e.g. Ar, CH4, N2, O2 low gas permeation, CO2, H2, He higher gas permeation
3) Low swelling in saturated hydrocarbons; significant swelling in aromatic hydro-
carbons. Aliphatic esters cause swelling, highly polar organic solvents dissolve under the effect of extreme swelling
4) Swelling in aliphatic and aromatic hydrocarbons and in chlorinated hydrocarbons
www.leoni-infrastructure-datacom.com
Office DataCenter Industry FO data cables 21 GigaLine®
Jacketing material for optical cables
Fiber optic cables are relatively thin and therefore very susceptible
to rodent damage. Depending on the application it is important
that fiber optic cables can offer protection against this type of
damage. There are no national or indeed international standards
or test specifications covering the corresponding requirement for
rodent protection.
The following construction has been customary in the market
in Europe (particularly in Germany, Austria and Switzerland)
since the early 1990s:
For outdoor cables, the usual aramid yarns for strain relief are
replaced with glass rovings. These glass yarns shatter and get
into the mouth and throat of the rodents. The animals associate
gnawing on cables with pain and usually stop.
The general rule is:
The more glass rovings, the greater the protection for
the cable.
The overall diameter should also be as large as possible.
Constructions with stranded loose tubes give even less favour-
able leverage in combination with the larger core diameter.
The cable then acts like a gag bit. Before the rodent reaches the
glass rovings, however, it first has to gnaw through the outer
sheath. Constructions with an additional polyamide sheath
(thickness 0.5 mm) have also proven themselves here as poly-
amide is very hard and smooth.
This combination of plastic, glass and moisture-absorbing
swelling material has to be gnawed through before rodent
reaches the loose tubes containing the internal optical fibers.
Metal armouring must be recommended as rodent protection
for all applications where rodent damage is to be expected.
This is the case, for example, with installation in shafts or con-
duits with a correspondingly large diameter, e.g. along railway
lines or motorways.
The following types of metal armouring are available:■■ Corrugated steel cladding
The most common metal armouring is the 0.155 mm thick
corrugated steel cladding due to its very good flexibility. ■■ Steel wire armour
The steel wire armour made from wires with a thickness
of up to 1.25 mm is very robust. ■■ Steel band
Steel band sheathing consists of two overlapping layers
of steel band that are wound around the cable.
In the case of cables with two sheaths with sheathing between
them, the ingress of water into the cable core is also prevented
provided the internal sheath is not damaged.
Despite all precautions, however, damage to the outer
sheath can never be fully ruled out.
Rodent protection for fiber optic cables
www.leoni-infrastructure-datacom.com
FO data cables22GigaLine®
Flame-retardant and halogen-free sheathThe outer sheath of the cable is self-extinguishing and does not propagate fire. The halogen-free sheath material forms neither toxic nor corrosive combustion gases in the event of fire.
Chemical resistanceGenerally good resistance to oil, petrol, acids and alkaline solutions.
Rodent proofThe cable core is protected against damage by rodents with glass rovings.
Note: Despite all the precautions, damage to the outer sheath can never be fully ruled out.
Rodent proofThe cable core is more heavily protected against damage by rodents with two sheaths and metal armouring.
Note: Despite all the precautions, damage to the outer sheath can never be fully ruled out.
Resistance to UV rays The cable outer sheath is resistant to UV rays.
Pictograms
www.leoni-infrastructure-datacom.com
Office DataCenter Industry FO data cables 23 GigaLine®
www.leoni-infrastructure-datacom.com
FO data cables24GigaLine®
Handling and safety notices when using optical cables
Please note the following when installing optical fibers:■■ Valid installation regulations for optical fibers■■ Valid industrial safety guidelines for handling optical fibers■■ VDE regulations (DIN EN 50174 Parts 1 to 3,
Cabling installation)
The following regulations also apply:■■ The drums must always be stored and transported standing
on their flanges■■ Please note the limit values specified in the respective
data sheet■■ Do not remove the protective packaging from the cable ends
during installation■■ Do not go below the permitted bending radius (see data sheet)
■■ Avoid soiling and mechanical loading of the assembled
connectors■■ Do not exceed the maximum tensile load of the cable in axial
direction before, during and after installation (use suitable aids)■■ The maximum tensile load only applies in conjunction with
adhesion with the strain relief elements■■ Installation is not permitted if the ambient temperature is
exceeded or gone below (specific value in the data sheet)■■ Cable runs must be selected so as to avoid mechanical loads
as far as possible and also minimise future loads■■ Mechanical stresses, for example caused by movement, must
be prevented, even during provisional installation■■ Compression of the outer sheath, for example by cable ties,
must be avoided when securing the cables
■■ After installation: carefully free the cable ends from the
packaging/pull tool■■ All cable ends must be protected from the ingress of moisture
before, during and after installation■■ Immersion with water must be avoided – the fibers and
connectors must not come into contact with water■■ Optical fibers must be unwound from the coil or ring without
torsion so that no kinks or twists can occur■■ Install optical cables with extreme care. Please make sure
that the fibers are neither overstretched nor compressed
– in addition to immediate damage, this also poses the threat
of problems with the long-term behaviour■■ When installing in protective conduits, please make sure that
these have no sharp edges and that kinks are avoided■■ The attenuation of each cable must be checked immediately
after installation using a suitable calibrated meter, otherwise
warranty claims may arise■■ Body and eye protection must be worn when handling bare
fibers from glass optical fibers, including if the cable is
damaged■■ Please note all regulations relating to eye safety
No. offibers
Buf-fered fiber-
typ
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
µ mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9…10/125
2 900 2.8x5.7 15.8 600 0.36 0.10 LKD 8DB7 0003 0000 LKD 8DA2 0003 0000 LKD 8DA5 2000 0000 LKD 8DA7 2000 0000 LKD 8DC7 2001 0000
2 600 1.8x3.7 7 400 0.14 0.04 LKD 8XB7 0013 0000 LKD 8XA2 0013 0000 LKD 8XA5 2013 0000 LKD 8XA7 0013 0000 LKD 8XC7 0013 0000
Advantages
■■ very flexible cable■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
➊ ➋ ➌
Type KL-I-V(ZN)H 2 G/E
Application
Connection cable and patch cord for structured cabling acc. to
ISO/IEC 11801 and EN 50173 (2nd edition).
In keeping with the fiber type ideal for all applications from
Classes OF 300 to OF 10000. Suitable for direct connector
assembly.
Installation in dry areas, in cable ducts, on cable trays or in
conduits.
Construction
➊ Two single cables (2.8 mm with 900 µm semi-ight buffered
loose tubes) with strain relief in fig. 8 sheath with separator
➋ Strain relief Non-metallic (aramid yarns)
➌ Cable sheath Halogen-free, flame-retardant compound
Sheath colour OS2 ●■Yellow
OM1e/OM2e ●■Orange
OM3 ●■Aqua
OM4 ●■Heather violet
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–10 °C up to +70 °C
Mechanical characteristics
Min. bending radius
(over flat side)
OM1e/2e/OS2 | OM3/4 bendable
static 30 mm | 15 mm
dynamic 60 mm | 30 mm
Max. crush strength long-term 600 N/dm
short-term 1000 N/dm
Fire performance
Smoke density IEC 61034
Halogen free IEC 60754-1
Flame retardancy IEC 60332-1-2, IEC 60332-3-22, Cat. A
www.leoni-infrastructure-datacom.com
Office DataCenter Industry FO data cablesOffice DataCenter 25 GigaLine®
GigaLine® Indoor cable, duplex fig 8
No. offibers
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9…10/125
2 3.1x5.2 18 600 0.63 0.18 LKD 8DB7 0011 0000 LKD 8DA2 0011 0000 LKD 8DA5 2001 0000 LKD 8DA7 2005 0000 LKD 8DC7 0010 0000
www.leoni-infrastructure-datacom.com
Type KL-I-V(ZN)HH 2 G/E
Application
Connection cable and patch cord for structured cabling acc.
to ISO/IEC 11801 and EN 50173 (2nd edition).
In keeping with the fiber type ideal for all applications from
Classes OF 300 to OF 10000. Suitable for direct connector
assembly.
Installation in dry areas, in cable ducts, on cable trays or in
conduits.
Construction
➊ Two single cables with strain relief (2.1 mm with 900 µm semi-
tight buffered fibers) running parallel under one sheath
➋ Strain relief Non-metallic (aramid yarns)
➌ Cable sheath Halogen-free, flame-retardant compound
Sheath colour OS2 ●■Yellow
OM1e/OM2e ●■Orange
OM3 ●■Aqua
OM4 ●■Heather violet
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–10 °C up to +70 °C
Mechanical characteristics
Min. bending radius
OM1e/2e/OS2 | OM3/4 bendable
static 35 mm | 20 mm
dynamic 65 mm | 35 mm
for single elements 30 mm | 15 mm
Max. tensile force long-term 600 N
Max. crush strength long-term 500 N/dm
short-term 750 N/dm
Fire performance
Smoke density IEC 61034
Halogen free IEC 60754-1
Flame retardancy IEC 60332-1-2, IEC 60332-3-22, Cat. A
Further characteristics
Cable bending IEC 60794-1-2 E11
GigaLine® Indoor cable, duplex fig 0
Advantages
■■ robust ■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
FO data cables
➊ ➋ ➌
26GigaLine®
No. offibers
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9…10/125
2 4.2 14 800 0.45 0.13 LKD 8MB7 0011 0000 LKD 8MA2 0011 0000 LKD 8MA5 2011 0000 LKD 8MA7 0011 0000 LKD 8MC7 0011 0000
4 4.8 21 800 0.47 0.13 LKD 8MB7 0012 0000 LKD 8MA2 0012 0000 LKD 8MA5 2012 0000 LKD 8MA7 0012 0000 LKD 8MC7 0012 0000
6 5.9 25 800 0.50 0.14 LKD 8MB7 0013 0000 LKD 8MA2 0013 0000 LKD 8MA5 2013 0000 LKD 8MA7 0013 0000 LKD 8MC7 0013 0000
8 6.1 30 800 0.52 0.14 LKD 8MB7 0014 0000 LKD 8MA2 0014 0000 LKD 8MA5 2014 0000 LKD 8MA7 0014 0000 LKD 8MC7 0014 0000
10 7.0 38 800 0.53 0.14 LKD 8MB7 0015 0000 LKD 8MA2 0015 0000 LKD 8MA5 2015 0000 LKD 8MA7 0015 0000 LKD 8MC7 0015 0000
12 7.0 38 800 0.55 0.15 LKD 8MB7 0016 0000 LKD 8MA2 0016 0000 LKD 8MA5 2016 0000 LKD 8MA7 0016 0000 LKD 8MC7 0016 0000
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter Industry
Type KL-I-V(ZN)H n G/E
Application
Campus/backbone cabling, suitable for direct connector assem-
bly. Connection cable and patch cord for structured cabling
acc. to ISO/IEC 11801 and EN 50173 (2nd edition). In keeping with
the fiber type ideal for all applications from Classes OF 300 to
OF 10000.
Installation in dry areas, in cable ducts, on cable trays or in c
onduits.
Construction
➊ Up to 12 semi-tight buffered fibers (900 µm)
stranded under one outer sheath
➋ Strain relief Non-metallic (aramid yarns)
➌ Cable sheath Halogen-free, flame-retardant compound
Sheath colour OS2 ●■Yellow
OM1e/OM2e ●■Orange
OM3 ●■Aqua
OM4 ●■Heather violet
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–10 °C up to +70 °C
Mechanical characteristics
Min. bending radius
OM1e/2e/OS2 | OM3/4 bendable
static 10 x outer Ø | 10 mm
dynamic 15 x outer Ø | 15 mm
for single elements 30 mm
Max. tensile force long-term 600 N
Max. crush strength long-term 500 N/dm
short-term 1000 N/dm
Fire performance
Smoke density IEC 61034
Halogen free IEC 60754-1
Flame retardancy IEC 60332-1-2, IEC 60332-3-22, Cat. A
Further characteristics
Cable bending IEC 60794-1-2 E11
GigaLine® Indoor cable, Mini-Breakout
Advantages
■■ flexible■■ space-saving■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
FO data cables
➊ ➋ ➌
27 GigaLine®
No. offibers
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9...10/125
2 7.0 40 800 1.10 0.30 LKD 8BB7 0011 0000 LKD 8BA2 0011 0000 LKD 8BA5 2011 0000 LKD 8BA7 0011 0000 LKD 8BC7 0011 0000
4 7.0 45 800 1.10 0.30 LKD 8BB7 0012 0000 LKD 8BA2 0012 0000 LKD 8BA5 2012 0000 LKD 8BA7 0012 0000 LKD 8BC7 0012 0000
6 8.2 65 1,000 1.18 0.32 LKD 8BB7 0013 0000 LKD 8BA2 0013 0000 LKD 8BA5 2013 0000 LKD 8BA7 0013 0000 LKD 8BC7 0013 0000
8 9.6 95 1,000 1.31 0.36 LKD 8BB7 0014 0000 LKD 8BA2 0014 0000 LKD 8BA5 2014 0000 LKD 8BA7 0014 0000 LKD 8BC7 0014 0000
10 11.0 135 1,000 1.42 0.39 LKD 8BB7 0015 0000 LKD 8BA2 0015 0000 LKD 8BA5 2015 0000 LKD 8BA7 0015 0000 LKD 8BC7 0015 0000
12 12.5 155 1,000 1.57 0.44 LKD 8BB7 0016 0000 LKD 8BA2 0016 0000 LKD 8BA5 2016 0000 LKD 8BA7 0016 0000 LKD 8BC7 0016 0000
www.leoni-infrastructure-datacom.com
GigaLine® Breakout cable
Advantages
■■ robust, crush resistant■■ each fiber is strain-relieved■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
Central element
FO data cables
➊ ➌ ➋➍
28GigaLine®
Type KL-I-V(ZN)HH n G/E
Application
Connection cable and patch cord for structured cabling acc.
to ISO/IEC 11801 and EN 50173 (2nd edition).
In keeping with the fiber type ideal for all applications from
Classes OF 300 to OF 10000. Suitable for direct connector
assembly.
Installation in dry areas, in cable ducts, on cable trays or in
conduits.
Construction
➊ Up to 12 single cables with strain relief as breakout elements
(2.1 mm with 900 µm semi-tight buffered fibers)
stranded under one outer sheath
➋ Ripcord under the outer sheath
➌ Strain relief Non-metallic (aramid yarns)
➍ Cable sheath Halogen-free, flame-retardant compound
Sheath colour OS2 ●■Yellow
OM1e/OM2e ●■Orange
OM3 ●■Aqua
OM4 ●■Heather violet
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–10 °C up to +70 °C
Mechanical characteristics
Min. bending radius
OM1e/2e/OS2 | OM3/4 bendable
static 15 x outer diameter
dynamic 20 x outer diameter
for single elements 30 mm | 15 mm
Max. crush strength long-term 1000 N/dm
short-term 1500 N/dm
Fire performance
Smoke density IEC 61034
Halogen free IEC 60754-1
Flame retardancy IEC 60332-1-2, IEC 60332-3-22, Cat. A
Further characteristics
Cable bending IEC 60794-1-2 E11
No. offibers
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9...10/125
6 5.9 25 800 0.50 0.14 LKD 8NB7 1003 0000 LKD 8NA2 1003 0000 LKD 8NA5 1003 0000 LKD 8NA7 1003 0000 LKD 8NC7 1003 0000
12 7.0 38 800 0.55 0.15 LKD 8NB7 1006 0000 LKD 8NA2 1006 0000 LKD 8NA5 1006 0000 LKD 8NA7 1006 0000 LKD 8NC7 1006 0000
24 9.4 72 800 0.92 0.25 LKD 8NB7 1009 0000 LKD 8NA2 1009 0000 LKD 8NA5 1009 0000 LKD 8NA7 1009 0000 LKD 8NC7 1009 0000
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter Industry
GigaLine® Universal cable, Mini-Breakout 800 N
Advantages
■■ flexible & space-saving■■ universal use■■ longitudinally watertight■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
FO data cables
➊ ➋ ➌
29 GigaLine®
Type KL-U-VQ(ZN)H n G/E
Application
Campus/backbone cabling, suitable for direct connector assem-
bly. Connection cable and patch cord for structured cabling acc.
to ISO/IEC 11801 and EN 50173 (2nd edition). In keeping with the
fiber type ideal for all applications from Classes OF 300 to OF
10000. House connections possible without additional intercon-
nection points (splices).
Installation indoors and outdoors in dry conduits, on covered
cable trays or in cable ducts. Mechanical pulling in with winches
is only permitted in conjunction with force measuring devices
with a logging feature.
Construction
➊ Up to 24 tight buffered fibers (900 µm)
stranded under one outer sheath
Buffered fiber colour code acc. to EIA/TIA598C
➋ Strain relief Non-metallic (aramid yarns)
➌ Cable sheath Halogen-free, flame-retardant compound
Sheath colour ●■Yellow
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–25 °C up to +60 °C
Mechanical characteristics
Min. bending radius
OM1e/2e/OS2 | OM3/4 bendable
static 10 | 5 x outer diameter
dynamic 15 | 10 x outer diameter
for single elements 30 | 15 mm
Max. crush strength long-term 300 N/dm
short-term 500 N/dm
Fire performance
Smoke density IEC 61034
Halogen free IEC 60754-1
Flame retardancy IEC 60332-1-2, IEC 60332-3-22, Cat. A
Further characteristics
Longitudinal watertightness IEC 60794-1-2 F5
Cable bending IEC 60794-1-2 E11
No. offibers
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9…10/125
1x2 7.6 65 2500 0.95 0.26 LKD 8UB7 00M1 0000 LKD 8UA2 00M1 0000 LKD 8UA500M1 0000 LKD 8UA7 00M1 0000 LKD 8UC7 00M1 0000
1x4 7.6 65 2500 0.95 0.26 LKD 8UB7 00M2 0000 LKD 8UA2 00M2 0000 LKD 8UA500M2 0000 LKD 8UA7 00M2 0000 LKD 8UC7 00M2 0000
1x6 7.6 65 2500 0.95 0.26 LKD 8UB7 00M3 0000 LKD 8UA2 00M3 0000 LKD 8UA500M3 0000 LKD 8UA7 00M3 0000 LKD 8UC7 00M3 0000
1x8 7.6 65 2500 0.95 0.26 LKD 8UB7 00M4 0000 LKD 8UA2 00M4 0000 LKD 8UA500M4 0000 LKD 8UA7 00M4 0000 LKD 8UC7 00M4 0000
1x10 7.6 65 2500 0.95 0.26 LKD 8UB7 00M5 0000 LKD 8UA2 00M5 0000 LKD 8UA500M5 0000 LKD 8UA7 00M5 0000 LKD 8UC7 00M5 0000
1x12 7.6 65 2500 0.95 0.26 LKD 8UB7 00M6 0000 LKD 8UA2 00M6 0000 LKD 8UA500M6 0000 LKD 8UA7 00M6 0000 LKD 8UC7 00M6 0000
1x16 8.2 73 2500 1.06 0.30 LKD 8UB7 00M7 0000 LKD 8UA2 00M7 0000 LKD 8UA500M7 0000 LKD 8UA7 00M7 0000 LKD 8UC7 00M7 0000
1x20 8.2 73 2500 1.06 0.30 LKD 8UB7 00M8 0000 LKD 8UA2 00M8 0000 LKD 8UA500M8 0000 LKD 8UA7 00M8 0000 LKD 8UC7 00M8 0000
1x24 8.2 73 2500 1.06 0.30 LKD 8UB7 00M9 0000 LKD 8UA2 00M9 0000 LKD 8UA500M9 0000 LKD 8UA7 00M9 0000 LKD 8UC7 00M9 0000
www.leoni-infrastructure-datacom.com
GigaLine® Universal cable, central 2500 N
➊ ➌ ➍➋
Advantages
■■ can be laid in the ground■■ universal use■■ longitudinally watertight■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
with OM3 and OM4 fibers
FO data cables30GigaLine®
Type KL-U-DQ(ZN)BH 1xn G/E
Application
Installation cable, suitable for campus/backbone cabling and
for structured cabling acc. to ISO/IEC 11801 and EN 50173 (2nd
edition). Ideal for all applications from Classes OF 300, OF 500,
OF 2000, OF 5000 and OF 10000. Suitable for installation indoors in
applications involving increased mechanical requirements as well
as risk of rodent damage. Suitable for splicing. House connections
possible without additional interconnection points (splices).
Installation indoors and outdoors in conduits, on covered cable
trays, in cable ducts or directly in the ground (in a bed of sand).
Mechanical pulling in with winches is only permitted in conjunc-
tion with force measuring devices with a logging feature.
Construction
➊ Central filled loose tube with max. 24 fibers, up to 12 fibers
diameter 2.9 mm, up to 24 fibers diameter 3.5 mm
Fiber colour code acc. to IEC 60304, Loose tube colour:
Yellow (E9/125), green (G50/125), blue (G62.5/125)
➋ Swellable threads
➌ Strain relief Non-metallic (glass rovings)
➍ Cable sheath Halogen-free, flame-retardant compound
Sheath colour ●■Black
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–25 °C up to +60 °C
Mechanical characteristics
Min. bending radius static 15 x outer diameter
dynamic 20 x outer diameter
Max. crush strength long-term 2000 N/dm
short-term 3500 N/dm
Fire performance
Smoke density IEC 61034
Halogen free IEC 60754-1
Flame retardancy IEC 60332-1-2, IEC 60332-3-24
Further characteristics
Longitudinal watertightness IEC 60794-1-2 F5
Impact resistance IEC 60794-1-2 E4
Cable bending IEC 60794-1-2 E11
Resistance to microbes
No. offibers
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9...10/125
2x12 11.4 141 4000 2.95 0.82 LKD 8UB7 1K06 0000 LKD 8UA2 1K06 0000 LKD 8UA5 1K06 0000 LKD 8UA7 1K06 0000 LKD 8UC7 1K06 0000
4x12 11.4 141 4000 2.95 0.82 LKD 8UB7 1K08 0000 LKD 8UA2 1K08 0000 LKD 8UA5 1K08 0000 LKD 8UA7 1K08 0000 LKD 8UC7 1K08 0000
8x12 13.7 200 4000 3.24 0.90 LKD 8UB7 1K11 0000 LKD 8UA2 1K11 0000 LKD 8UA5 1K11 0000 LKD 8UA7 1K11 0000 LKD 8UC7 1K11 0000
12x12 17 300 4000 4.32 1.20 LKD 8UB7 1K13 0000 LKD 8UA2 1K13 0000 LKD 8UA5 1K13 0000 LKD 8UA7 1K13 0000 LKD 8UC7 1K13 0000
Further types on request
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter Industry
GigaLine® Universal cable, stranded 4000 N
➊ ➌ ➎➍➋
Advantages
■■ can be laid in the ground■■ universal use■■ longitudinally watertight■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
with OM3 and OM4 fibers
FO data cables 31 GigaLine®
Type KL-U-DQ(ZN)BH nxm G/E
Application
Installation cable, suitable for campus/backbone cabling and for
structured cabling acc. to ISO/IEC 11801 and EN 50173 (2nd
edition). Ideal for applications from Classes OF 300 to OF 10000.
Suitable for installation in applications involving increased mecha-
nical requirements as well as risk of rodent damage. Suitable for
splicing. House connections possible without additional intercon-
nection points (splices).
Installation indoors and outdoors in conduits, on covered cable
trays, in cable ducts or directly in the ground (in a bed of sand).
Mechanical pulling in with winches is only permitted in conjunc-
tion with force measuring devices with a logging feature.
Construction
➊ Stranded filled loose tube with up to 12 fibers
and blind elements, if applicable
Fiber colour code acc. to IEC 60304
Loose tube colour: Counting wire red, counting direction wire
white, yellow (E9/125), green (G50/125), blue (G62.5/125)
➋ Central GFR strength member
➌ Swellable threads
➍ Strain relief Non-metallic (glass rovings)
➎ Cable sheath Halogen-free, flame-retardant compound
Sheath colour ●■Black
Thermal characteristics
Transport/storage
Installation
Operating temp.
–40 °C up to +70 °C
–5 °C up to +50 °C
–40 °C up to +60 °C
Mechanical characteristics
Min. bending radius static 15 x outer diameter
dynamic 20 x outer diameter
Max. crush strength long-term 3000 N/dm
short-term 4000 N/dm
Fire performance
Smoke density IEC 61034
Halogen free IEC 60754-1
Flame retardancy IEC 60332-1-2, IEC 60332-3-24
Further characteristics
Longitudinal watertightness IEC 60794-1-2 F5
Impact resistance IEC 60794-1-2 E4
Cable bending IEC 60794-1-2 E11
Resistance to microbes
No. offibers
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9…10/125
1x2 11.6 171 2500 1.93 0.53 LKD 8UB7 99K1 0000 LKD 8UA2 99K1 0000 LKD 8UA5 99K1 0000 LKD 8UA7 99K1 0000 LKD 8UC7 99K1 0000
1x4 11.6 171 2500 1.93 0.53 LKD 8UB7 99K2 0000 LKD 8UA2 99K2 0000 LKD 8UA5 99K2 0000 LKD 8UA7 99K2 0000 LKD 8UC7 99K2 0000
1x6 11.6 171 2500 1.93 0.53 LKD 8UB7 99K3 0000 LKD 8UA2 99K3 0000 LKD 8UA5 99K3 0000 LKD 8UA7 99K3 0000 LKD 8UC7 99K3 0000
1x8 11.6 171 2500 1.93 0.53 LKD 8UB7 99K4 0000 LKD 8UA2 99K4 0000 LKD 8UA5 99K4 0000 LKD 8UA7 99K4 0000 LKD 8UC7 99K4 0000
1x10 11.6 171 2500 1.93 0.53 LKD 8UB7 99K5 0000 LKD 8UA2 99K5 0000 LKD 8UA5 99K5 0000 LKD 8UA7 99K5 0000 LKD 8UC7 99K5 0000
1x12 11.6 171 2500 1.93 0.53 LKD 8UB7 99K6 0000 LKD 8UA2 99K6 0000 LKD 8UA5 99K6 0000 LKD 8UA7 99K6 0000 LKD 8UC7 99K6 0000
1x16 12.1 181 2500 2.14 0.59 LKD 8UB7 99K7 0000 LKD 8UA2 99K7 0000 LKD 8UA5 99K7 0000 LKD 8UA7 99K7 0000 LKD 8UC7 99K7 0000
1x20 12.1 181 2500 2.14 0.59 LKD 8UB7 99K8 0000 LKD 8UA2 99K8 0000 LKD 8UA5 99K8 0000 LKD 8UA7 99K8 0000 LKD 8UC7 99K8 0000
1x24 12.1 181 2500 2.14 0.59 LKD 8UB7 99K9 0000 LKD 8UA2 99K9 0000 LKD 8UA5 99K9 0000 LKD 8UA7 99K9 0000 LKD 8UC7 99K9 0000
www.leoni-infrastructure-datacom.com
GigaLine® Universal cable, central 2500 N
➊ ➌ ➍➍ ➎➋
Advantages
■■ optimal rodent armouring■■ can be laid in the ground■■ universal use■■ longitudinally and transversally
waterproof■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
FO data cables32GigaLine®
Type KL-U-DQ(ZN)H(SR)H 1xn G/E
Application
Installation cable, suitable for campus/backbone cabling and for
structured cabling acc. to ISO/IEC 11801 and EN 50173 (2nd edi-
tion). Ideal for all applications from Classes OF 300, OF 500, OF
2000, OF 5000 and OF 10000. Suitable for installation in applica-
tions involving increased mechanical requirements as well as risk
of rodent damage. Suitable for splicing. House connections possi-
ble without additional interconnection points (splices).
Installation indoors and outdoors in dry conduits, on covered cable
trays, in cable ducts or directly in the ground. Mechanical pulling
in with winches is only permitted in conjunction with force measu-
ring devices with a logging feature.
Construction
➊ Central filled loose tube with max. 24 fibers,
up to 12 fibers diameter 2.9 mm, up to 24 fibers diameter 3.5 mm
Fiber colour code acc. to IEC 60304,
Loose tube colour: Yellow (E9/125), green (G50/125), blue (G62.5/125)
➋ Strain relief Non-metallic (glass rovings)
➌ Inner sheath Halogen-free, flame-retardant compound
Inner sheath colour ●■Black
➍ Armouring Corrugated steel cladding
➎ Cable sheath Halogen-free, flame-retardant compound
Sheath colour ●■Black
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–25 °C up to +60 °C
Mechanical characteristics
Min. bending radius static 15 x outer diameter
dynamic 20 x outer diameter
Max. crush strength long-term 2500 N/dm
short-term 3500 N/dm
Fire performance
Smoke density IEC 61034
Halogen free IEC 60754-1
Flame retardancy IEC 60332-1-2, IEC 60332-3-24
Further characteristics
Longitudinal watertightness IEC 60794-1-2 F5
Impact resistance IEC 60794-1-2 E4
Cable bending IEC 60794-1-2 E11
Resistance to microbes
A functioning communication system is of vital importance
in the event of a fire. It is therefore vital that a fiber optic cable
maintains its system integrity. The results of the fire tests cer-
tify that the "fire secured" fiber optic data cables maintain their
system integrity and their insulation integrity for 90 and 120
minutes respectively in the event of a fire.
In particular in public facilities and buildings where large num-
bers of people gather (e.g. tunnels, airports, hotels, etc.), fire
alarm, SOS telephone and video monitoring systems are used
to coordinate rescue measures and fire fighting efforts as effici-
ently as possible. Also in industrial facilities, processes have to
be terminated in a controlled manner in order to avoid serious
secondary damage to humans and the environment.
Modern communication systems are increasingly using optical
data transmission systems for transmitting data. These are often
the only option given the high requirements for data rates and
transmission paths.
With its "fire secured" universal cables, LEONI offers products
which are tested according to IEC 60331-25 and EN 50200 and
protect the fibers from exposure to fire thanks to their special
construction with a fire barrier.
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter Industry
LEONI „fire secured“ FO data cableswith a fire barrier to protect the fibers in the event of a fire
FO data cables 33 GigaLine®
No. offibers
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9…10/125
1x2 10.3 115 2500 1.03 0.29 LKD 8UB7 00B1 0000 LKD 8UA2 00B1 0000 LKD 8UA5 00B1 0000 LKD 8UA7 00B1 0000 LKD 8UC7 00B1 0000
1x4 10.3 115 2500 1.03 0.29 LKD 8UB7 00B2 0000 LKD 8UA2 00B2 0000 LKD 8UA5 00B2 0000 LKD 8UA7 00B2 0000 LKD 8UC7 00B2 0000
1x6 10.3 115 2500 1.03 0.29 LKD 8UB7 00B3 0000 LKD 8UA2 00B3 0000 LKD 8UA5 00B3 0000 LKD 8UA7 00B3 0000 LKD 8UC7 00B3 0000
1x8 10.3 115 2500 1.03 0.29 LKD 8UB7 00B4 0000 LKD 8UA2 00B4 0000 LKD 8UA5 00B4 0000 LKD 8UA7 00B4 0000 LKD 8UC7 00B4 0000
1x10 10.3 115 2500 1.03 0.29 LKD 8UB7 00B5 0000 LKD 8UA2 00B5 0000 LKD 8UA5 00B5 0000 LKD 8UA7 00B5 0000 LKD 8UC7 00B5 0000
1x12 10.3 115 2500 1.03 0.29 LKD 8UB7 00B6 0000 LKD 8UA2 00B6 0000 LKD 8UA5 00B6 0000 LKD 8UA7 00B6 0000 LKD 8UC7 00B6 0000
1x16 10.8 125 2500 1.28 0.36 LKD 8UB7 00B7 0000 LKD 8UA2 00B7 0000 LKD 8UA5 00B7 0000 LKD 8UA7 00B7 0000 LKD 8UC7 00B7 0000
1x20 10.8 125 2500 1.28 0.36 LKD 8UB7 00B8 0000 LKD 8UA2 00B8 0000 LKD 8UA5 00B8 0000 LKD 8UA7 00B8 0000 LKD 8UC7 00B8 0000
1x24 10.8 125 2500 1.28 0.36 LKD 8UB7 00B9 0000 LKD 8UA2 00B9 0000 LKD 8UA5 00B9 0000 LKD 8UA7 00B9 0000 LKD 8UC7 00B9 0000
www.leoni-infrastructure-datacom.com
GigaLine® „Fire secured“ universal cable, central with CI
Advantages
■■ system integrity during expo-
sure to fire for at least 90 min-
utes■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
➊ ➌ ➍➍ ➎➋
FO data cables34GigaLine®
Type KL-U-D(ZN)BH 1xn G/E
Application
Installation cable suitable for campus/backbone cabling
and structured cabling acc. to ISO/IEC 11801 and EN 50173
(2nd edition). Ideal for all applications from Classes OF 300 to
OF 10000. Suitable for installation in applications involving
increased mechanical requirements as well as risk of rodent
damage. Suitable for splicing. House connections possible
without additional interconnection points (splices).
Installation in dry areas, in cable ducts, on cable trays or in
conduits.
Construction
➊ Central filled loose tube with max. 24 fibers,
up to 12 fibers diam. 3.5 mm, up to 24 fibers diam. 4.0 mm
➋ with fire protection barrier
Fiber colour code acc. to IEC 60304, Loose tube colour:
Yellow (E9/125), green (G50/125), blue (G62.5/125)
➌ Strain relief Non-metallic (glass rovings)
➍ Cable sheath Halogen-free, flame-retardant compound
➎ Ripcords under the sheath
Sheath colour ●■Yellow
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
– 5 °C up to +50 °C
–25 °C up to +60 °C
Mechanical characteristics
Min. bending radius static 15 x outer diameter
dynamic 20 x outer diameter
Max. crush strength long-term 3000 N/dm
short-term 4500 N/dm
Fire performance
Smoke density IEC 61034
Halogen free IEC 60754-1
Flame retardancy IEC 60332-1-2, IEC 60332-3-22
Further characteristics
Total system and Acc. to IEC 60331-11 and -25
insulation integrity EN 50200/DIN VDE 0482 Part 1
(90 minutes)
Max. change in attenuation 2.0 dB
No. offibers
Outer diam.
approx.
Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9…10/125
1x2 12.5 215 2500 2.80 0.78 LKD 8UB7 00C1 0000 LKD 8UA2 00C1 0000 LKD 8UA5 00C1 0000 LKD 8UA7 00C1 0000 LKD 8UC7 00C1 0000
1x4 12.5 215 2500 2.80 0.78 LKD 8UB7 00C2 0000 LKD 8UA2 00C2 0000 LKD 8UA5 00C2 0000 LKD 8UA7 00C2 0000 LKD 8UC7 00C2 0000
1x6 12.5 215 2500 2.80 0.78 LKD 8UB7 00C3 0000 LKD 8UA2 00C3 0000 LKD 8UA5 00C3 0000 LKD 8UA7 00C3 0000 LKD 8UC7 00C3 0000
1x8 12.5 215 2500 2.80 0.78 LKD 8UB7 00C4 0000 LKD 8UA2 00C4 0000 LKD 8UA5 00C4 0000 LKD 8UA7 00C4 0000 LKD 8UC7 00C4 0000
1x10 12.5 215 2500 2.80 0.78 LKD 8UB7 00C5 0000 LKD 8UA2 00C5 0000 LKD 8UA5 00C5 0000 LKD 8UA7 00C5 0000 LKD 8UC7 00C5 0000
1x12 12.5 215 2500 2.80 0.78 LKD 8UB7 00C6 0000 LKD 8UA2 00C6 0000 LKD 8UA5 00C6 0000 LKD 8UA7 00C6 0000 LKD 8UC7 00C6 0000
1x16 12.5 215 2500 2.80 0.78 LKD 8UB7 00C7 0000 LKD 8UA2 00C7 0000 LKD 8UA5 00C7 0000 LKD 8UA7 00C7 0000 LKD 8UC7 00C7 0000
1x20 12.5 215 2500 2.80 0.78 LKD 8UB7 00C8 0000 LKD 8UA2 00C8 0000 LKD 8UA5 00C8 0000 LKD 8UA7 00C8 0000 LKD 8UC7 00C8 0000
1x24 12.5 215 2500 2.80 0.78 LKD 8UB7 00C9 0000 LKD 8UA2 00C9 0000 LKD 8UA5 00C9 0000 LKD 8UA7 00C9 0000 LKD 8UC7 00C9 0000
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter Industry
GigaLine® „Fire secured“ universal cable, central with CI
Advantages
■■ system integrity during expo-
sure to fire for at least
120 minutes■■ optimal rodent armouring■■ longitudinally and transversally
waterproof■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
➊ ➌ ➍➍ ➎➋
FO data cables 35 GigaLine®
Type KL-U-DQ(ZN)H(SR)H 1xn G/E
Application
Installation cable suitable for campus/backbone cabling
and structured cabling acc. to ISO/IEC 11801 and EN 50173
(2nd edition). For applications from Classes OF 300 to OF 10000.
Suitable for installation in applications involving increased
mechanical requirements as well as risk of rodent damage.
Suitable for splicing. House connections possible without addi-
tional interconnection points (splices). Installation indoors and
outdoors in dry conduits, on covered cable trays or in cable
ducts. Mechanical pulling in with winches is only permitted in
conjunction with force measuring devices with a logging feature.
Construction
➊ Central filled loose tubes with max. 24 fibers,
up to 12 fibers diam. 3.5 mm, up to 24 fibers diam. 4.0 mm
Fiber colour code acc. to IEC 60304, Loose tube colour:
Yellow (E9/125), green (G50/125), blue (G62.5/125)
➋ Strain relief Non-metallic (glass rovings)
➌ Inner sheath Halogen-free, flame-retardant compound
➍ Armouring Corrugated steel sheath as fire protection
barrier and rodent protection
➎ Cable sheath Halogen-free, flame-retardant compound
Sheath colour ●■Yellow
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–25 °C up to +60 °C
Mechanical characteristics
Min. bending radius static 15 x outer diameter
dynamic 20 x outer diameter
Max. crush strength long-term 2500 N/dm
short-term 3500 N/dm
Fire performance
Smoke density IEC 61034
Halogen free IEC 60754-1
Flame retardancy IEC 60332-1-2, IEC 60332-3-22
Further characteristics
Total system and Acc. to IEC 60331-11 and -25
insulation integrity EN 50200: 2000 Class PH120
& BS 8434: 2003 Part 2 (120 minutes)
No. offibers
Outer diam.
approx.
Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9…10/125
1x2 7.4 39 1750 1.21 0.34 LKD 8AB7 00A1 0000 LKD 8AA2 00A1 0000 LKD 8AA5 00A1 0000 LKD 8AA7 00A1 0000 LKD 8AC7 00A1 0000
1x4 7.4 39 1750 1.21 0.34 LKD 8AB7 00A2 0000 LKD 8AA2 00A2 0000 LKD 8AA5 00A2 0000 LKD 8AA7 00A2 0000 LKD 8AC7 00A2 0000
1x6 7.4 39 1750 1.21 0.34 LKD 8AB7 00A3 0000 LKD 8AA2 00A3 0000 LKD 8AA5 00A3 0000 LKD 8AA7 00A3 0000 LKD 8AC7 00A3 0000
1x8 7.4 39 1750 1.21 0.34 LKD 8AB7 00A4 0000 LKD 8AA2 00A4 0000 LKD 8AA5 00A4 0000 LKD 8AA7 00A4 0000 LKD 8AC7 00A4 0000
1x10 7.4 39 1750 1.21 0.34 LKD 8AB7 00A5 0000 LKD 8AA2 00A5 0000 LKD 8AA5 00A5 0000 LKD 8AA7 00A5 0000 LKD 8AC7 00A5 0000
1x12 7.4 39 1750 1.21 0.34 LKD 8AB7 00A6 0000 LKD 8AA2 00A6 0000 LKD 8AA5 00A6 0000 LKD 8AA7 00A6 0000 LKD 8AC7 00A6 0000
1x16 7.8 45 1750 1.39 0.39 LKD 8AB7 00A7 0000 LKD 8AA2 00A7 0000 LKD 8AA5 00A7 0000 LKD 8AA7 00A7 0000 LKD 8AC7 00A7 0000
1x20 7.8 45 1750 1.39 0.39 LKD 8AB7 00A8 0000 LKD 8AA2 00A8 0000 LKD 8AA5 00A8 0000 LKD 8AA7 00A8 0000 LKD 8AC7 00A8 0000
1x24 7.8 45 1750 1.39 0.39 LKD 8AB7 00A9 0000 LKD 8AA2 00A9 0000 LKD 8AA5 00A9 0000 LKD 8AA7 00A9 0000 LKD 8AC7 00A9 0000
Advantages
■■ economical solution for
outdoor installation■■ longitudinally watertight■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
www.leoni-infrastructure-datacom.com
GigaLine® Outdoor cable, central 1750 N
➊ ➌➋
FO data cables36GigaLine®
Type KL-A-DQ(ZN)B2Y 1xn G/E
Application
Outdoor cable for direct installation in the ground, in conduits
and where there is a risk of rodent damage in MAN (city net-
works) and LAN (campus/backbone). Suitable for structured
cabling acc. to ISO/IEC 11801 and EN 50173 (2nd edition).
In keeping with the fiber type ideal for all applications from
Classes OF 300 to OF 10000. Easy to install thanks to grease-
free, dry cable core. Suitable for splicing.
Installation indoors, in conduits, on covered cable trays,
in cable ducts or directly in the ground. Mechanical pulling
in with winches is only permitted in conjunction with force
measuring devices with a logging feature.
Construction
➊ Central filled loose tube with up to 24 fibers
Fiber colour code acc. to IEC 60304, Loose tube colour:
Yellow (E9/125), green (G50/125), blue (G62.5/125)
➋ Strain relief Non-metallic (glass rovings)
➌ Cable sheath PE, UV-resistant
Sheath colour ●■Black
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–25 °C up to +60 °C
Mechanical characteristics
Min. bending radius static 15 x outer diameter
dynamic 20 x outer diameter
Max. crush strength long-term 1500 N/dm
short-term 2500 N/dm
Fire performance
Halogen free IEC 60754-1
Further characteristics
Longitudinal watertightness IEC 60794-1-2 F5
Impact resistance IEC 60794-1-2 E4
Cable bending IEC 60794-1-2 E11
No. offibers
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9...10/125
2x12 11.5 115 4000 4.10 1.14 LKD 8AB7 0K06 0000 LKD 8AA2 0K06 0000 LKD 8AA5 0K06 0000 LKD 8AA7 0K06 0000 LKD 8AC7 0K06 0000
4x12 11.5 115 4000 4.10 1.14 LKD 8AB7 0K08 0000 LKD 8AA2 0K08 0000 LKD 8AA5 0K08 0000 LKD 8AA7 0K08 0000 LKD 8AC7 0K08 0000
8x12 13.7 165 4000 4.96 1.38 LKD 8AB7 0K11 0000 LKD 8AA2 0K11 0000 LKD 8AA5 0K11 0000 LKD 8AA7 0K11 0000 LKD 8AC7 0K11 0000
12x12 17.0 230 4000 6.19 1.72 LKD 8AB7 0K13 0000 LKD 8AA2 0K13 0000 LKD 8AA5 0K13 0000 LKD 8AA7 0K13 0000 LKD 8AC7 0K13 0000
Further types on request
Advantages
■■ economical solution for
outdoor installation■■ longitudinally watertight■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
www.leoni-infrastructure-datacom.com
Office DataCenter Industry
GigaLine® Outdoor cable, stranded 4000 N
➊ ➌ ➎➍➋
FO data cablesOffice Industry 37 GigaLine®
Type KL-A-DQ(ZN)B2Y nxm G/E
Application
Outdoor cable for direct installation in the ground, in conduits
and where there is a risk of rodent damage in MAN (city net-
works) and LAN (campus/backbone). Suitable for structured
cabling acc. to ISO/IEC 11801 and EN 50173 (2nd edition).
In keeping with the fiber type ideal for all applications from
Classes OF 300 to OF 10000. Easy to install thanks to grease-
free, dry cable core. Suitable for splicing.
Installation indoors, in conduits, on covered cable trays, in
cable ducts or directly in the ground. Mechanical pulling
in with winches is only permitted in conjunction with force
measuring devices with a logging feature.
Construction
➊ Stranded filled loose tube diameter 2.4 mm with
up to 12 fibers and blind elements, if applicable
Fiber colour code acc. to IEC 60304
Loose tube colour: Counting wire red, counting direction wire
white, yellow (E9/125), green (G50/125), blue (G62.5/125)
➋ central strength member
➌ Swellable nonwoven
➍ Strain relief Non-metallic (glass rovings)
➎ Cable sheath PE, UV-resistant
Sheath colour ●■Black
Thermal characteristics
Transport/storage
Installation
Operating temp.
–40 °C up to +70 °C
–10 °C up to +50 °C
–40 °C up to +60 °C
Mechanical characteristics
Min. bending radius static 15 x outer diameter
dynamic 20 x outer diameter
Max. crush strength long-term 3000 N/dm
short-term 4000 N/dm
Fire performance
Halogen free IEC 60754-1
Further characteristics
Longitudinal watertightness IEC 60794-1-2 F5
Impact resistance IEC 60794-1-2 E4
Cable bending IEC 60794-1-2 E11
No. offibers
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9…10/125
1x2 11.0 119 1750 3.01 1.08 LKD 8AB7 00L1 0000 LKD 8AA2 00L1 0000 LKD 8AA5 00L1 0000 LKD 8AA7 00L1 0000 LKD 8AC7 00L1 0000
1x4 11.0 119 1750 3.01 1.08 LKD 8AB7 00L2 0000 LKD 8AA2 00L2 0000 LKD 8AA5 00L2 0000 LKD 8AA7 00L2 0000 LKD 8AC7 00L2 0000
1x6 11.0 119 1750 3.01 1.08 LKD 8AB7 00L3 0000 LKD 8AA2 00L3 0000 LKD 8AA5 00L3 0000 LKD 8AA7 00L3 0000 LKD 8AC7 00L3 0000
1x8 11.0 119 1750 3.01 1.08 LKD 8AB7 00L4 0000 LKD 8AA2 00L4 0000 LKD 8AA5 00L4 0000 LKD 8AA7 00L4 0000 LKD 8AC7 00L4 0000
1x10 11.0 119 1750 3.01 1.08 LKD 8AB7 00L5 0000 LKD 8AA2 00L5 0000 LKD 8AA5 00L5 0000 LKD 8AA7 00L5 0000 LKD 8AC7 00L5 0000
1x12 11.0 119 1750 3.01 1.08 LKD 8AB7 00L6 0000 LKD 8AA2 00L6 0000 LKD 8AA5 00L6 0000 LKD 8AA7 00L6 0000 LKD 8AC7 00L6 0000
1x16 11.6 127 1750 3.30 1.19 LKD 8AB7 00L7 0000 LKD 8AA2 00L7 0000 LKD 8AA5 00L7 0000 LKD 8AA7 00L7 0000 LKD 8AC7 00L7 0000
1x20 11.6 127 1750 3.30 1.19 LKD 8AB7 00L8 0000 LKD 8AA2 00L8 0000 LKD 8AA5 00L8 0000 LKD 8AA7 00L8 0000 LKD 8AC7 00L8 0000
1x24 11.6 127 1750 3.30 1.19 LKD 8AB7 00L9 0000 LKD 8AA2 00L9 0000 LKD 8AA5 00L9 0000 LKD 8AA7 00L9 0000 LKD 8AC7 00L9 0000
www.leoni-infrastructure-datacom.com
GigaLine® Outdoor cable, central 1750 N
Advantages
■■ optimal rodent armouring■■ longitudinally and transversally
waterproof■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
➊ ➌ ➍ ➎➋
FO data cables38GigaLine®
Type KL-A-DQ(ZN)2Y(SR)2Y 1xn G/E
Application
Outdoor cable for direct installation in the ground, in conduits
and where there is an increased risk of rodent damage in
MAN (city networks) and LAN (campus/backbone). Suitable
for structured cabling acc. to ISO/IEC 11801 and EN 50173
(2nd edition). In keeping with the fiber type ideal for all appli-
cations from Classes OF 300 to OF 10000. Easy to install thanks
to grease-free, dry cable core. Suitable for splicing.
Installation outdoors in conduits, on covered cable trays.
Mechanical pulling in with winches is only permitted in con-
junction with force measuring devices with a logging feature.
Construction
➊ Central filled loose tube with up to 24 fibers
Fiber colour code acc. to IEC 60304
➋ Strain relief Non-metallic (glass rovings)
➌ Inner sheath PE
➍ Armouring Corrugated steel cladding as highly
effective rodent protection
➎ Outer sheath PE, UV-resistant
Sheath colour ●■Black
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
– 5 °C up to +50 °C
–25 °C up to +60 °C
Mechanical characteristics
Min. bending radius static 15 x outer diameter
dynamic 20 x outer diameter
Max. crush strength long-term 2500 N/dm
short-term 3500 N/dm
Fire performance
Halogen free IEC 60754-1
Further characteristics
Longitudinal watertightness IEC 60794-1-2 F5
Impact resistance IEC 60794-1-2 E4
Cable bending IEC 60794-1-2 E11
No. offibers
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9…10/125
2x12 17.5 285 4000 10.62 2.95 LKD 8AB7 0A06 0000 LKD 8AA2 0A06 0000 LKD 8AA5 0A06 0000 LKD 8AA7 0A06 0000 LKD 8AC7 0A06 0000
4x12 17.5 285 4000 10.62 2.95 LKD 8AB7 0A08 0000 LKD 8AA2 0A08 0000 LKD 8AA5 0A08 0000 LKD 8AA7 0A08 0000 LKD 8AC7 0A08 0000
8x12 19.6 345 4000 12.24 3.40 LKD 8AB7 0A11 0000 LKD 8AA2 0A11 0000 LKD 8AA5 0A11 0000 LKD 8AA7 0A11 0000 LKD 8AC7 0A11 0000
12x12 21.5 400 4000 13.80 3.80 LKD 8AB7 0A13 0000 LKD 8AA2 0A13 0000 LKD 8AA5 0A13 0000 LKD 8AA7 0A13 0000 LKD 8AC7 0A13 0000
Further types on request
www.leoni-infrastructure-datacom.com
Office DataCenter Industry
GigaLine® Outdoor cable, stranded 4000 N
Advantages
■■ optimal rodent armouring■■ longitudinally and transversally
waterproof■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
➊ ➌ ➍ ➏➎➋ ➐
FO data cablesOffice Industry 39 GigaLine®
Type KL-A-DQ(ZN)2Y(SR)2Y nxm G/E
Application
Outdoor cable for direct installation in the ground, in conduits
and where there is an increased risk of rodent damage in MAN
(city networks) and LAN (campus/backbone). Suitable for use in
structured cabling acc. to ISO/IEC 11801 and EN 50173 (2nd edi-
tion). In keeping with the fiber type ideal for all applications from
Classes OF 300 to OF 10000. Easy to install thanks to grease-free,
dry cable core. Suitable for splicing.
Installation outdoors, in conduits, on covered cable trays
or directly in the ground. Mechanical pulling in with winches
is only permitted in conjunction with force measuring devices
with a logging feature.
Construction
➊ Stranded filled loose tube diam. 2.4 mm with up to 12 fibers
Fiber colour code acc. to IEC 60304
Loose tube colour: Counting wire red, counting direction wire
white, yellow (E9/125), green (G50/125), blue (G62.5/125)
➋ Central strength member
➌ Swellable nonwoven
➍ Strain relief Non-metallic (glass rovings)
➎ Inner sheath PE, colour ●■Black
➏ Armouring Corrugated steel cladding as highly
effective rodent protection
➐ Outer sheath PE, UV-resistant
Sheath colour ●■Black
Thermal characteristics
Transport/storage
Installation
Operating temp.
–40 °C up to +70 °C
–10 °C up to +50 °C
–40 °C up to +60 °C
Mechanical characteristics
Min. bending radius static 15 x outer-Ø
dynamic 20 x outer-Ø
max. crush
strength
long-term 3000 N/dm
short-term 5000 N/dm
Brandverhalten
Halogen free IEC 60754-1
Further characteristics
Longitudinal watertightness IEC 60794-1-2 F5
Impact resistance IEC 60794-1-2 E4
Cable bending IEC 60794-1-2 E11
Further types on request
No. offibers
Outer diam.
approx.Weight approx.
Max. strain relief
Fire loadapprox.
Order no.
mm kg/km N MJ/m kWh/m OM1e
G62.5/125OM2e
G50/125OM3 bendable
G50/125OM4 bendable
G50/125OS2
E9…10/125
2x12 12.1 140 4000 4.97 1.38 LKD 8AB7 0406 0000 LKD 8AA2 0406 0000 LKD 8AA5 0406 0000 LKD 8AA7 0A06 0000 LKD 8AC7 0406 0000
4x12 12.1 140 4000 4.97 1.38 LKD 8AB7 0408 0000 LKD 8AA2 0408 0000 LKD 8AA5 0408 0000 LKD 8AA7 0A08 0000 LKD 8AC7 0408 0000
8x12 14.4 200 4000 5.87 1.63 LKD 8AB7 0411 0000 LKD 8AA2 0411 0000 LKD 8AA5 0411 0000 LKD 8AA7 0A11 0000 LKD 8AC7 0411 0000
12x12 17.7 300 4000 7.24 2.01 LKD 8AB7 0413 0000 LKD 8AA2 0413 0000 LKD 8AA5 0413 0000 LKD 8AA7 0A13 0000 LKD 8AC7 0413 0000
www.leoni-infrastructure-datacom.com
GigaLine® Outdoor cable, stranded with sheath, 4000 N
Advantages
■■ optimally longitudinally and
transversally waterproof■■ more than twice the bandwidth
with OM2e fibers■■ for applications up to 40/100G
➊ ➌➍➎➋
FO data cables40GigaLine®
Type KL-A-DF(ZN)(L)2Y nxm G/E
Application
Water-blocking gel-filled longitudinally and transversely water-
tight outdoor cable for installation directly in the ground, in
conduits and where there is a risk of rodent damage in MAN
(city networks) and LAN (campus/backbone). Suitable for use
in structured cabling acc. to ISO/IEC 11801 and EN 50173
(2nd edition). In keeping with the fiber type ideal for all appli-
cations from Classes OF 300 to OF 10000. Suitable for splicing.
Installation indoors and outdoors in conduits, on covered cable
trays or directly in the ground. Mechanical pulling in with
winches is only permitted in conjunction with force measuring
devices with a logging feature.
Construction
➊ Stranded filled loose tube diameter 2.4 mm with up to
12 fibers and blind elements, if applicable
Fiber colour code acc. to IEC 60304
Loose tube colour: Counting wire red, counting direction wire
white, yellow (E9/125), green (G50/125), blue (G62.5/125)
➋ Central strength member
➌ Filling Water-blocking gel filling in twist cavities
of the cable core
➍ Strain relief Non-metallic (glass rovings)
➎ Outer sheath Aluminium sheath, resistant to UV rays
(aluminium tape with PE sheath)
Sheath colour ●■Black
Thermal characteristics
Transport/storage
Installation
Operating temp.
–40 °C up to +70 °C
–5 °C up to +50 °C
–40 °C up to +60 °C
Mechanical characteristics
Min. bending radius static 15 x outer diameter
dynamic 20 x outer diameter
Max. crush strength long-term 1500 N/dm
short-term 3000 N/dm
Fire performance
Halogen free IEC 60754-1
Further characteristics
Longitudinal watertightness IEC 60794-1-2 F5
Impact resistance IEC 60794-1-2 E4
Cable bending IEC 60794-1-2 E11
www.leoni-infrastructure-datacom.com
Office DataCenter Industry FO data cablesOffice Industry 41 GigaLine®
www.leoni-infrastructure-datacom.com
42GigaLine® FO connectivity
GigaLine®
FO connectivity
www.leoni-infrastructure-datacom.com
Office DataCenter Industry 43 GigaLine® FO connectivity
GigaLine® FO connectivity page
GigaLine® FO cabling systems 44
GigaLine® Trunk and splice boxes 47
o ■dc■ Fiber optic trunk box• telescopic trunk box• fixed trunk box
4849
o ■dc■ Fiber optic splice box• telescopic splice box• fixed splice box
5052
GigaLine® Compact – fiber optic distribution system 55
o ■dc■ Compact fiber optic rack 56
o ■dc■ Compact fiber optic module for pre-assembled breakout cables 57
o ■dc■ Compact fiber optic module for splicing solutions 58
GigaLine® Office and floor distributors 61
o ■ Fiber optic office and floor distributors• size A for up to 4 splice cassettesx• size B for up to 24 splice cassettes
6263
GigaLine® Fiber-To-The-Desk (FTTD) wall outlets 65
o ■ FTTD wall outlets• for surface mounting• for flush mounting
66
o ■ FTTD wall outlets• cable reservoir• splice tray for cable reservoir
67
o ■ FTTD outlet for cable ducts 68
o ■ FTTD mounting bracket for cable ducts 69
o ■ Office
dc■ DataCenter
i ■ Industry
www.leoni-infrastructure-datacom.com
44GigaLine® FO connectivity
GigaLine® is a perfectly coordinated system made up
of components optimised for performance and quality.
The interplay of high-quality fibers which far exceed the
standard and connectors with high-quality workmanship enable
maximum performance and range for the respective application
(GbE/10 GbE).
The system components are optimised to meet the
requirements for both distance and data rate. That is why LEONI
consistently uses its own j-fiber fibers (cables, pigtails, patch
cords).
Maximum transmission lengths for 10 Gigabit Ethernet system solutions.
OM2eOM3
bendableOM4
bendable OS2
Max. link length* 150 300 550 10.000
Attenuation budget** 1.8 dB 2.6 dB 2.6 dB 6.2 dB
Max. fiber attenuation 0.37 dB 0.75 dB 1.37 dB 3.6 dB
Number of possible connectors
6 8 6 12
Recommendedconnectors
LC, MTP/ MPO, SC
LC, MTP/ MPO, SC
LC, MTP / MPO,
SC
LC, SC
* Based on 10 GbE** All specifications are based on 850 nm or 1,310 nm
The GigaLine® system is determined by the application, required
link length and transmission protocol.
The table below shows the protocol-dependent attenuation
budget according to EN 50173-1 for the 10 Gigabit Ethernet pro-
tocol. From this is derived the number of possible connections
based on the overall link. The following harmonised compo-
nents were taken into consideration when putting together the
system:
■■ Fiber optic cables (GigaLine®) with laser/dispersion-optimised
multimode fibers that far exceed the standard and have
appropriate performance reserves (for fiber specifications see
section on GigaLine® fiber optic data cables)
■■ Fiber optic connectors with low insertion losses and high
return losses
GigaLine® FO cabling systems High-performance components for building a fiber optic infrastructure
The requirements for fibers and connectors differ depending on the field of application.
OM1e OM2 OM2e OM3 OM4 OS2
Industry SC, ST
Office LC, SC
DataCenter LC, MTP / MPO
Campus LC, SC
GigaLine® has components for every field of application.
Gig
aLin
e® w
all
outl
ets
Gig
aLin
e®
wal
l dis
trib
utor
s
Gig
aLin
e®
trun
k an
d sp
lice
boxe
s
Gig
aLin
e®
DCl
ink
Gig
aLin
e®
Com
pact
Industry
Office
DataCenter
Campus
www.leoni-infrastructure-datacom.com
Office DataCenter Industry 45 GigaLine® FO connectivity
Graph 1: System reserves of GigaLine® 150, 300 and 550 relative to the standard
Quality is our benchmark
Assembly of fiber optic connectors involves both adjustment
of the fibers in the ferrule as well as time-consuming grinding
and polishing. The aim here is to machine the connector so pre-
cisely by means of optimised processes that the insertion loss
and reflections are kept to a minimum. This is done by means of
PC polishing (PC = physical contact). Spherical polishing of the
ferrule spring mounted in the connector housing produces a
fiber/fiber transition at the end faces. In other words when two
connectors are plugged into one coupling, the spring pressure
pushes out all the air between the mating fibers of both connec-
tors. The glass/glass transition then has very low reflections and
low attenuation.
To maximise the performance of a PC connector, the surface
parameters of the connectors must be carefully checked during
the polishing process. The interferometer is an indicatory
measuring instrument for this. The overlaps of coherent light
waves are used to measure the quality of optical surfaces (fer-
rule surfaces).
The most important parameters are:■■ Apex offset
(offset between the highest point and the centre of the fiber)■■ Radius of the connector interface (fiber/ferrule)■■ Fiber height (undercut, protrusion)
These parameters are decisive for the long-term behaviour and
therefore the quality of a fiber optic connector.
Insertion loss of the connectors used in GigaLine® system components.
Fiber typeInsertion loss
typ.Return
loss
G62.5/125 OM1e 0.2 dB > 35 dB
G50/125 OM2e 0.2 dB > 35 dB
G50/125 OM3 bendable 0.2 dB > 35 dB
G50/125 OM4 bendable 0.2 dB > 35 dB
E9..10/125 OS2 0.2 dB > 50 dB
E9..10/125 OS2 APC 0.2 dB > 65 dB
Graph 1 shows the system reserves afforded by the high-quality
fibers and connectors in relation to EN 50173.
Decisive advantages of these system reserves are:■■ Longer transmission lengths for certain applications
(100 Mbit/s, 1 GbE, 10 GbE, 40 GbE, 100 GbE)■■ The option to insert more patch cords or splices■■ Additional attenuation caused by aging processes can be
curtailed■■ Network extensions can be realised with ease and a certain
level of assurance within the link lengths
GigaLine® BIMMF as well as patch and trunk cable
– the perfect combination
GigaLine® fiber optics are equipped with bend insensitive
OM3 and OM4 fibers (j-BendAble). That means significant added
value for you:■■ Greater reliability with higher packing density and installation
in constricted areas due to the low bending loss.■■ Low-risk patching in operation - the data transmission
remains constantly stable despite significant bending.■■ The doubled tensile strength of the fibers minimises the risk
of a fiber tear in the patch field (200 kpsi in comparison to the
standard with 100 kpsi).■■ Maximum security for a mix and match with fibers of other
manufacturers due to the minimum transition damping.
LEONI OM4 bendableLEONI OM3 bendableLEONI OM2eStandard OM3Standard OM2
Distance/km Attenuation-limited
operation
Dispersion-limited
operation
Bandwidth/MHz
www.leoni-infrastructure-datacom.com
46GigaLine® FO connectivity
www.leoni-infrastructure-datacom.com
Office DataCenter Industry 47 GigaLine® FO connectivity
GigaLine® Trunk and splice boxes Multifunctional housing technology, 19"
GigaLine® trunk and splice boxes can be used in all areas of
building data cabling. The construction of the components
ensures speed and reliability during initial installation,
maintenance and extension.
All boxes are pre-assembled ready to install and constructed so
that two cables can be inserted via cable glands or two divider
heads can be inserted from above. A breakout panel to which
the cables can be secured using cable ties is available as an
alternative.
Your guarantee for quick and reliable installation:■■ The box body is made from aluminium and therefore very light■■ The boxes are assembled ready to install■■ The permissible bending radii as well as ease of installation
are guaranteed even with high packing densities■■ The telescopic version offers the advantage that all compo-
nents are easily accessible for testing and maintenance work
GigaLine® trunk and splice box:■■ Boxes with one rack unit as fixed installation or telescopic
version■■ Boxes with two rack units are always telescopic■■ The front panel is made from galvanised steel panel and
Light grey RAL 7035, powder coated ■■ One rack unit can be equipped with up to
24 x SC Duplex, 24 x LC Duplex, 24 x MT-RJ, 24 x E 2000,
24 x ST, 24 x FC couplings
www.leoni-infrastructure-datacom.com
48GigaLine® FO connectivity
Multimode
Number of fibers
SC Duplex, beigePlastic/PhBz
LC Duplex, beigePlastic/PhBz
LC Duplex, aquaPlastic/Cer
LC Duplex, heather violet Plastic/Cer
E2000, beigePlastic/Cer
6 LKD 9D32 A022 0000 LKD 9D32 A032 0000 LKD 9D32 A178 0000 LKD 9D32 A181 0000 LKD 9D32 A036 0000
12 LKD 9D32 A023 0000 LKD 9D32 A033 0000 LKD 9D32 A179 0000 LKD 9D32 A182 0000 LKD 9D32 A037 0000
24 LKD 9D32 A000 0000 LKD 9D32 A034 0000 LKD 9D32 A180 0000 LKD 9D32 A183 0000 LKD 9D32 A038 0000
48 LKD 9D32 A024 0000 LKD 9D32 A035 0000 LKD 9D32 A177 0000 LKD 9D32 A184 0000
Other configurations available on request
GigaLine® Trunk box telescopic
Description
Telescopic fiber optic patch panel for pre-assembled trunk
cables. Suitable for terminating up to 48 optical fibers.
Construction
Box
Front panel and
mounting bracket
Capacity
Labelling
Dimensions
Weight
Aluminium, with dust protective cover
telescopic and removable drawer, depth
continuously adjustable by up to 50 mm
Galvanised steel panel, powder coated
Colour: Grey RAL 7035
Installation of up to 2 trunk cables
Channel 1–12 / 1–24 (screen printing)
A/B coding with SC/ST/FC configuration
19" / 1 RU
44 mm x 483 mm x 220 mm (HxWxD)
approx. 1.7 kg
Configuration
Equipment
Couplings
available with up to 24 slots
SC Duplex, FC-PC/FC-APC, ST
E2000/E2000 HRL, MTRJ, LC Duplex
Accessories (optional)
Breakout panel for securing cables using cable ties
Singlemode
Number of fibers
SC DuplexMet/Cer
SC Duplex, bluePlastic/Cer
LCD, bluePlastic/Cer
E2000, bluePlastic/Cer
E2000HRL, greenPlastic/Cer
6 LKD 9D32 A039 0000 LKD 9D32 A003 0000 LKD 9D32 A014 0000 LKD 9D32 A017 0000 LKD 9D32 A020 0000
12 LKD 9D32 A040 0000 LKD 9D32 A004 0000 LKD 9D32 A015 0000 LKD 9D32 A018 0000 LKD 9D32 A002 0000
24 LKD 9D32 A041 0000 LKD 9D32 A005 0000 LKD 9D32 A001 0000 LKD 9D32 A019 0000 LKD 9D32 A021 0000
48 LKD 9D32 A095 0000 LKD 9D32 A006 0000 LKD 9D32 A016 0000
Designation Order no.
GigaLine® Telescopic trunk box see table
Breakout panel LKD 9D60 0000 0000
GigaLine® Fiber optic trunk boxBox 19" / 1 RU, telescopic or fixed
Advantages
■■ light as a feather■■ easy to install
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter 49 GigaLine® FO connectivity
Multimode
Number of fibers
SC Duplex, beigePlastic/PhBz
LC Duplex, beigePlastic/PhBz
LC Duplex, aquaPlastic/Cer
LC Duplex, heather violetPlastic/Cer
E2000, beigePlastic/Cer
6 LKD 9D42 A019 0000 LKD 9D42 A027 0000 LKD 9D42 A113 0000 LKD 9D42 A117 0000 LKD 9D42 A030 0000
12 LKD 9D42 A020 0000 LKD 9D42 A028 0000 LKD 9D42 A114 0000 LKD 9D42 A118 0000 LKD 9D42 A031 0000
24 LKD 9D42 A000 0000 LKD 9D42 A029 0000 LKD 9D42 A115 0000 LKD 9D42 A119 0000 LKD 9D42 A032 0000
48 LKD 9D42 A046 0000 LKD 9D42 A050 0000 LKD 9D42 A116 0000 LKD 9D42 A120 0000
Other configurations available on request
Singlemode
Number of fibers
SC DuplexMet/Cer
SC Duplex, bluePlastic/Cer
LCD, bluePlastic/Cer
E2000, bluePlastic/Cer
E2000HRL, greenPlastic/Cer
6 LKD 9D42 A034 0000 LKD 9D42 A003 0000 LKD 9D42 A012 0000 LKD 9D42 A014 0000 LKD 9D42 A017 0000
12 LKD 9D42 A035 0000 LKD 9D42 A004 0000 LKD 9D42 A013 0000 LKD 9D42 A015 0000 LKD 9D42 A018 0000
24 LKD 9D42 A036 0000 LKD 9D42 A005 0000 LKD 9D42 A033 0000 LKD 9D42 A016 0000 LKD 9D42 A002 0000
48 LKD 9D42 A047 0000 LKD 9D42 AXXX 0000 LKD 9D42 A001 0000
GigaLine® Trunk box fixed
Description
Fiber optic patch box for pre-assembled trunk cables.
Suitable for terminating up to 48 optical fibers.
Construction
Box
Front panel
Capacity
Labelling
Dimensions
Weight
Aluminium, with dust protective cover
Galvanised steel panel, powder coated
Colour: Grey RAL 7035
Installation of up to 2 trunk cables
Channel 1–12 / 1–24 (screen printing)
A/B coding with SC/ST/FC configuration
19" / 1 RU
44 mm x 483 mm x 220 mm (HxWxD)
approx. 1.4 kg
Configuration
Equipment
Couplings
available with up to 24 slots
SC Duplex, FC-PC/FC-APC, ST
E2000/E2000 HRL, MTRJ, LC Duplex
Accessories (optional)
Breakout panel for securing cables using cable ties
Designation Order no.
GigaLine® Smart trunk, fixed see table
Breakout panel LKD 9D60 0000 0000
Advantages
■■ light as a feather■■ easy to install
www.leoni-infrastructure-datacom.com
50GigaLine® FO connectivity
GigaLine® Splice box telescopic
Description
Telescopic fiber optic patch panel for up to 48 optical fibers.
For terminating fiber optic transmission links with pigtails.
Construction
Box
Front panel and
Mounting bracket
Pigtails
Labelling
Dimensions
Weight
Aluminium, with dust protective cover
telescopic and removable drawer, depth
continuously adjustable by up to 50 mm
Galvanised steel panel, powder coated,
Colour: Grey RAL 7035
Pigtails ready for splicing and plugged in
(colours acc. to DIN IEC 60304)
Channel 1–12 / 1–24 (screen printing)
A/B coding with SC/ST/FC configuration
19" / 1 RU
44 mm x 483 mm x 220 mm (HxWxD)
approx. 1.8 kg
Optical characteristics
Insertion loss typ.
Return loss typ.
for all fiber types 0.2 dB
G62.5/125 OM1e > 35 dB
G50/125 OM2e > 35 dB
G50/125 OM3 > 35 dB
G50/125 OM4 > 35 dB
E9..10/125 OS2 > 50 dB
E9..10/125 OS2 APC > 65 dB
Configuration
Equipment
Couplings
available with up to 24 slots
SC Duplex, FC-PC/FC-APC, ST,
E2000/E2000 HRL, MTRJ, LC Duplex
Accessories
1 x M20 cable gland
Splice cassette
Crimp splice protective holder
Accessories (optional)
Breakout panel for securing cables using cable ties
Designation Order no.
GigaLine® Telescopic splice box see table
Breakout panel LKD 9D60 0000 0000
GigaLine® Fiber optic splice boxBox 19" / 1 RU, telescopic
Advantages
■■ light as a feather■■ easy to install■■ best optical
properties
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter 51 GigaLine® FO connectivity
Singlemode OS2 E9..10/125
Number of fibers
SC DuplexMet/Cer
SC Duplex, bluePlastic/Cer
LCD, bluePlastic/Cer
E2000, bluePlastic/Cer
E2000HRL, greenPlastic/Cer
6 LKD 9D31 A093 0000 LKD 9D31 A003 0000 LKD 9D31 A014 0000 LKD 9D31 A018 0000 LKD 9D31 A021 0000
12 LKD 9D31 A094 0000 LKD 9D31 A004 0000 LKD 9D31 A015 0000 LKD 9D31 A019 0000 LKD 9D31 A022 0000
24 LKD 9D31 A002 0000 LKD 9D31 A005 0000 LKD 9D31 A016 0000 LKD 9D31 A020 0000 LKD 9D31 A023 0000
48 LKD 9D31 A096 0000 LKD 9D31 A006 0000 LKD 9D31 A017 0000
Multimode OM1e G62.5/125
Number of fibers
SC Duplex, beigePlastic/PhBz
LCD, beigePlastic/PhBz
6 LKD 9D31 A078 0000 LKD 9D31 A089 0000
12 LKD 9D31 A079 0000 LKD 9D31 A090 0000
24 LKD 9D31 A080 0000 LKD 9D31 A091 0000
48 LKD 9D31 A081 0000 LKD 9D31 A092 0000
Multimode OM2e G50/125
Number of fibers
SC Duplex, beige Met/Cer
SC Duplex, beigePlastic/PhBz
LCD, beigePlastic/PhBz
E2000, beigePlastic/Cer
6 LKD 9D31 AXXX 0000 LKD 9D31 A024 0000 LKD 9D31 A035 0000 LKD 9D31 A039 0000
12 LKD 9D31 AXXX 0000 LKD 9D31 A025 0000 LKD 9D31 A036 0000 LKD 9D31 A040 0000
24 LKD 9D31 A180 0000 LKD 9D31 A026 0000 LKD 9D31 A037 0000 LKD 9D31 A041 0000
48 LKD 9D31 AXXX 0000 LKD 9D31 A027 0000 LKD 9D31 A038 0000
Multimode OM3 G50/125
Number of fibers
SC Duplex, beigeMet/Cer
SC Duplex, beigePlastic/PhBz
LCD, aquaPlastic/Cer
E2000, beigePlastic/Cer
6 LKD 9D31 AXXX 0000 LKD 9D31 A042 0000 LKD 9D31 A198 0000 LKD 9D31 A057 0000
12 LKD 9D31 A139 0000 LKD 9D31 A043 0000 LKD 9D31 A199 0000 LKD 9D31 A058 0000
24 LKD 9D31 A000 0000 LKD 9D31 A044 0000 LKD 9D31 A186 0000 LKD 9D31 A059 0000
48 LKD 9D31 A001 0000 LKD 9D31 A045 0000 LKD 9D31A281 0000
Multimode OM4 G50/125
Number of fibers
SC Duplex, beigeMet /Ker
SC Duplex, beigePlastic/PhBz
LCD, heather violetPlastic/Cer
E2000, beigePlastic/Cer
6 LKD 9D31 AXXX 0000 LKD 9D31 A060 0000 LKD 9D31 A200 0000 LKD 9D31 A075 0000
12 LKD 9D31 AXXX 0000 LKD 9D31 A061 0000 LKD 9D31 A295 0000 LKD 9D31 A076 0000
24 LKD 9D31 A229 0000 LKD 9D31 A062 0000 LKD 9D31 AXXX 0000 LKD 9D31 A077 0000
48 LKD 9D31 A230 0000 LKD 9D31 A063 0000 LKD 9D31 AXXX 0000
Other configurations available on request
www.leoni-infrastructure-datacom.com
52GigaLine®
Advantages
■■ light as a feather■■ easy to install■■ best optical
properties
FO connectivity
GigaLine® Splice box fixed
Description
Fiber optic patch panel, for up to 48 optical fibers.
For terminating fiber optic transmission links with pigtails.
Construction
Box
Front panel
Pigtails
Labelling
Dimensions
Weight
Aluminium with dust protective cover
Galvanised steel panel,
Colour: Grey RAL 7035
Pigtails ready for splicing and plugged in
(colours acc. to DIN IEC 60304)
Channel 1–12 / 1–24 (screen printing)
A/B coding with SC/ST/FC configuration
19" / 1 RU
44 mm x 483 mm x 220 mm (HxWxD)
approx. 1.5 kg
Optical characteristics
Insertion loss typ.
Return loss typ.
for all fiber types 0.2 dB
G62.5/125 OM1e > 35 dB
G50/125 OM2e > 35 dB
G50/125 OM3 > 35 dB
G50/125 OM4 > 35 dB
E9..10/125 OS2 > 50 dB
E9..10/125 OS2 APC > 65 dB
Configuration
Equipment
Couplings
available with up to 24 slots
SC Duplex/SC Duplex, FC-PC, FC-PC(HRL)
(SM) , ST/ST, E2000/E2000, E2000HRL/
E2000HRL (SM), MT-RJ/MT-RJ (MM),
LC Duplex
Accessories
1 x M20 cable gland
Splice cassette
Crimp splice protective holder
Accessories (optional)
Breakout panel for securing cables using cable ties
Designation Order no.
GigaLine® Splice box, fixed see table
Breakout panel LKD 9D60 0000 0000
GigaLine® Fiber optic splice boxBox 19" / 1 RU, fixed
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter 53 GigaLine® FO connectivity
Singlemode OS2 E9..10/125
Number of fibers
SC Duplex, blueMet/Cer
SC Duplex, bluePlastic/PhBz
E2000, bluePlastic/Cer
E2000HRL, greenPlastic/Cer
6 LKD 9D41 A100 0000 LKD 9D41 AXXX 0000 LKD 9D41 A018 0000 LKD 9D41 A021 0000
12 LKD 9D41 A080 0000 LKD 9D41 AXXX 0000 LKD 9D41 A019 0000 LKD 9D41 A022 0000
24 LKD 9D41 A081 0000 LKD 9D41 AXXX 0000 LKD 9D41 A020 0000 LKD 9D41 A023 0000
48 LKD 9D41 A159 0000 LKD 9D41 AXXX 0000
Multimode OM1e G62.5/125
Number of fibers
SC Duplex, beigeMet/Cer
SC Duplex, beigePlastic/PhBz
LCD, beigePlastic/PhBz
E2000, beigePlastic/Cer
6 LKD 9D41 AXXX 0000 LKD 9D41 A065 0000 LKD 9D41 A074 0000 LKD 9D41 AXXX 0000
12 LKD 9D41 AXXX 0000 LKD 9D41 A066 0000 LKD 9D41 A075 0000 LKD 9D41 AXXX 0000
24 LKD 9D41 AXXX 0000 LKD 9D41 A067 0000 LKD 9D41 A076 0000 LKD 9D41 AXXX 0000
48 LKD 9D41 AXXX 0000 LKD 9D41 AXXX 0000
Multimode OM2e G50/125
Number of fibers
SC Duplex, beigeMet/Cer
SC Duplex, beigePlastic/PhBz
LCD, beigePlastic/PhBz
E2000, beigePlastic/Cer
6 LKD 9D41 AXXX 0000 LKD 9D41 A024 0000 LKD 9D41 A035 0000 LKD 9D41 A039 0000
12 LKD 9D41 A079 0000 LKD 9D41 A025 0000 LKD 9D41 A036 0000 LKD 9D41 A040 0000
24 LKD 9D41 A169 0000 LKD 9D41 A026 0000 LKD 9D41 A037 0000 LKD 9D41 A041 0000
48 LKD 9D41 AXXX 0000 LKD 9D41 A147 0000 LKD 9D41 A166 0000
Multimode OM3 G50/125
Number of fibers
SC Duplex, beigeMet/Cer
SC Duplex, beigePlastic/PhBz
LCD, aquaPlastic/Cer
E2000, beigePlastic/Cer
6 LKD 9D41 AXXX 0000 LKD 9D41 A002 0000 LKD 9D41 A229 0000 LKD 9D41 A047 0000
12 LKD 9D41 A121 0000 LKD 9D41 A006 0000 LKD 9D41 A230 0000 LKD 9D41 A048 0000
24 LKD 9D41 A077 0000 LKD 9D41 A010 0000 LKD 9D41 A231 0000 LKD 9D41 A049 0000
48 LKD 9D41 AXXX 0000 LKD 9D41 AXXX 0000 LKD 9D41 A232 0000
Multimode OM4 G50/125
Number of fibers
SC Duplex, beigeMet/Cer
SC Duplex, beigePlastic/PhBz
LCD, heather violetPlastic/Cer
E2000, beigePlastic/Cer
6 LKD 9D41 AXXX 0000 LKD 9D41 A050 0000 LKD 9D41 AXXX 0000 LKD 9D41 A062 0000
12 LKD 9D41 AXXX 0000 LKD 9D41 A051 0000 LKD 9D41 A238 0000 LKD 9D41 A063 0000
24 LKD 9D41 AXXX 0000 LKD 9D41 A052 0000 LKD 9D41 A233 0000 LKD 9D41 A064 0000
48 LKD 9D41 AXXX 0000 LKD 9D41 AXXX 0000 LKD 9D41 A234 0000
Other configurations available on request
www.leoni-infrastructure-datacom.com
54GigaLine® FO connectivity
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter 55 GigaLine® FO connectivity
GigaLine® Compact is a user-friendly fiber optic distribution
system that can be configured with up to 144 fibers with con-
ventional couplings such as SC, ST, E 2000 and with 288 fibers
with LC Duplex couplings.
The system combines compactness with optimum fiber optic
management. GigaLine® Compact is ideal for applications where
space is tight and maximum flexibility is required.
GigaLine® Compact rack with excess-length drawer 3+1 RU■■ Width: 19"/84 HP■■ Height 4 RU (3 RU rack + 1 RU excess-length drawer)■■ Can be configured with up to 12 modules■■ Excess-length drawer can be pulled out towards the rear,
for holding loose tube reserves and securing the fiber optic
cables, alternatively up to 6 pre-assembled trunk cables with
up to 48 fibers can be secured using cable glands■■ Management panel for patch cord routing and adherence
to the bending radii
GigaLine® Compact module 3 RU/7 HP■■ For up to 24 fibers■■ Available with up to 12 couplings■■ Configured with SC Duplex, ST, E2000, FC-PC, MT-RJ
or LC Duplex couplings■■ Front panel: Aluminium, with mounting screws■■ Including splicing cassette and excess-length cassette■■ Buffered fiber pigtails are inserted, stripped and coloured
(primary and secondary coating) acc. to the DIN IEC 60304
colour code ready for splicing for fast and secure installation■■ Fiber qualities: OM1e, OM2e, OM3, OM4 and OS2■■ The couplings can be retrofitted at any time
GigaLine® rack with excess-length drawer 3+1 RU
GigaLine® Compact module 3 RU, 7 HP
GigaLine® Compact – fiber optic distribution systemfor maximum packing density and flexibility
www.leoni-infrastructure-datacom.com
56GigaLine® FO connectivity
GigaLine® Compact rack
Description
Rack with 84 HP. The excess-length drawer for the loose tubes
can be pulled out to the rear. Max. 6 trunk cables with 48 fibers
each can be inserted from above or up to 12 loose tube cables
with max. 288 fibers can be inserted from the front.
Construction
Box
Excess-length
drawer
Dimensions
Aluminium with permanently installed
runners for the built-in modules
For clear organisation of the
loose tube reserves and securing,
can be pulled out to the rear
19" / 4 RU
176 mm x 483 mm x 295 mm (HxWxD)
Accessories
1 x M20 cable gland
5 x patch cord routing
Designation Order no.
GigaLine® Compact rack LKD 9D50 0000 0000
Loose tube guide plate LKD 9D50 0005 0000
Dummy front panel 7 HP LKD 9D50 0004 0000
Loose tube guide plate
Rack – rear view
Rack for GigaLine® trunk cables – rear view
Accessories (optional)
Loose tube guide
plate
Dummy front panel
7HP
To protect the loose tubes on the rear,
especially in open racks
To close off unused
module slots
GigaLine® Compact fiber optic rackwith mounted excess-length drawer 3+1 RU
Advantages
■■ for high packing
densities ■■ clearly laid out
cable management
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter 57 GigaLine®
GigaLine® Compact trunk module
Description
Built-in module, available with 3, 6 and 12 slots.
Including excess-length cassette.
Construction
Module rack
Front panel
Capacity
Dimensions
Aluminium
Aluminium, with mounting screws
for up to 24 fibers
7 HP / 1 RU
128 mm x 35 mm x 240 mm (HxWxD)
Configuration
Couplings SC Duplex, ST, E2000, FC-PC, MT-RJ,
LC Duplex , LC-Quad
Accessories
Labelling strips
Cable ties
FO connectivity
Singlemode
Number of fibers
SC Duplex, bluePlastic/Cer
LCD, bluePlastic/Cer
E2000, bluePlastic/Cer
6 LKD 9D52 0000 0000 LKD 9D52 0008 0000 LKD 9D52 0011 0000
12 LKD 9D52 0001 0000 LKD 9D52 0009 0000 LKD 9D52 0012 0000
24 LKD 9D52 0010 0000 (LC-Quad)
Multimode
Number of fibers
SC Duplex, beigePlastic/PhBz
LC Duplex, beigePlastic/PhBz
LC Duplex, aquaPlastic/Cer
LC Duplex, heather violetPlastic/Cer
6 LKD 9D52 0016 0000 LKD 9D52 0024 0000 LKD 9D52 0XXX 0000 LKD 9D52 0XXX 0000
12 LKD 9D52 0017 0000 LKD 9D52 0025 0000 LKD 9D52 0XXX 0000 LKD 9D52 0XXX 0000
24 LKD 9D52 0026 0000 (LC-Quad) LKD 9D52 0036 0000 (LC-Quad) LKD 9D52 0037 0000 (LC-Quad)
Further connectors available on request
GigaLine® Compact fiber optic moduleBuilt-in module for pre-assembled breakout cables, 3 RU / 7 HP
www.leoni-infrastructure-datacom.com
58GigaLine® FO connectivity
GigaLine® Compact splice module
Description
Built-in module, available with 3, 6 and 12 slots.
Including splice cassette and excess-length cassette.
The buffered fiber pigtails are inserted, stripped and coloured
(primary and secondary coating) acc. to the DIN IEC 60304
colour code ready for splicing for fast and secure installation.
Construction
Module rack
Front panel
Pigtails
Dimensions
Aluminium
Aluminium, with mounting screws
Up to 24 pigtails ready for splicing
and plugged in
(colours acc. to DIN IEC 60304)
7 HP / 1 RU
128 mm x 35 mm x 240 mm (HxWxD)
Optical characteristics
Insertion loss typ.
Return loss typ.
for all fiber types 0.2 dB
G62.5/125 OM1e > 35 dB
G50/125 OM2e > 35 dB
G50/125 OM3 > 35 dB
G50/125 OM4 > 35 dB
E9..10/125 OS2 > 50 dB
E9..10/125 OS2 APC > 65 dB
Configuration
Couplings The couplings can be retrofitted
at any time
Accessories
Labelling strips
Cable ties for securing the loose tubes
Crimp splice protective holder
Protective tube for loose tubes 90 cm
GigaLine® Compact fiber optic moduleBuilt-in module for splicing solutions
Advantages
■■ best optical
properties
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter 59 GigaLine® FO connectivity
Singlemode OS2 E9.. 10/125
Number of fibers
SC Duplex, blueMet/Cer
LC Duplex, bluePlastic/Cer
E2000, bluePlastic/Cer
6 LKD 9D51 0003 0000 LKD 9D51 0010 0000 LKD 9D51 0014 0000
12 LKD 9D51 0036 0000 LKD 9D51 0011 0000 LKD 9D51 0015 0000
24 LKD 9D51 0012 0000 (LC-Quad)
Multimode OM1e G62.5/125
Number of fibers
SC DuplexPlastic/PhBz
LC DuplexPlastic/PhBz
6 LKD 9D51 0071 0000 LKD 9D51 0077 0000
12 LKD 9D51 0072 0000 LKD 9D51 0078 0000
24 LKD 9D51 0079 0000 (LC-Quad)
Multimode OM2e G50/125
Number of fibers
SC DuplexPlastic/PhBz
LC DuplexPlastic/PhBz
6 LKD 9D51 0023 0000 LKD 9D51 0029 0000
12 LKD 9D51 0024 0000 LKD 9D51 0030 0000
24 LKD 9D51 0031 0000 (LC-Quad)
Multimode OM3 G50/125
Number of fibers
SC DuplexPlastic/PhBz
LC Duplex, aquaPlastic/Cer
6 LKD 9D51 0039 0000 LKD 9D51 0095 0000
12 LKD 9D51 0040 0000 LKD 9D51 0096 0000
24 LKD 9D51 0092 0000 (LC-Quad)
Multimode OM3e G50/125
Number of fibers
SC DuplexPlastic/PhBz
LC Duplex, heather violetPlastic/Cer
6 LKD 9D51 0055 0000 LKD 9D51 00XX 0000
12 LKD 9D51 0056 0000 LKD 9D51 XXXX 0000
24 LKD 9D51 0093 0000 (LC-Quad)
Further configurations on request
www.leoni-infrastructure-datacom.com
60GigaLine® FO connectivity
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice 61 GigaLine® FO connectivity
Network installations are increasingly being implemented
with disturbance-proof fiber optic systems technology with
future capabilities. This allows EMC problems as well as dif-
ferent earthing potentials to be avoided for cabling reaching
through whole buildings.
When a fiber optic cabling system with a star structure is used
in a building, the long ranges involved make it possible to
dispense with active components on the individual floors. 19"
distributor cabinets and separate security areas (rooms) as well
as the associated power supply are no longer necessary.
The space-saving office and floor distributors are perfectly
suited for the transitions from high-fiber backbone cables to
breakout cables for workplace cabling. They are easy to install
and offer space-saving organisation and optimum protection
for fiber optic systems engineering.
GigaLine® stands for a high degree of flexibility:■■ The GigaLine® office and floor distributors can be optionally
equipped with splice cassettes and/or distributor plates for
holding fiber optical couplings■■ Later modifications to the components used are possible
at any time■■ Holds up to 288 fibers■■ The buffered fiber pigtails are coloured acc. to the DIN IEC
60304 colour code for fast and reliable installation■■ The pigtail buffered fibers in the splice cassette are stripped
and ready for splicing■■ The incoming and outgoing fiber optic cables are fixed
to a strain relief strip in the housing■■ The cable entries are sealed via brush strips or PG cable glands■■ Housings have one removable/lockable swing door■■ Housing colour: Light grey RAL 7035
GigaLine® office and floor distributor
➔ Are tailored to the customer's requirements and supplied
fully assembled
➔ Are available in 2 sizes
Basement
GigaLine® Office and floor distributorsMultifunctional housing for FTTD/FTTO cabling
Office 1 Office 2 Office 3
Office 4 Office 5 Office 6 Office 7
www.leoni-infrastructure-datacom.com
62GigaLine® FO connectivity
GigaLine® Fiber optic office and floor distributorsWall distributor for up to 4 or 24 splice cassettes
Advantages
■■ space-saving■■ universal use
Designation Order no.
GigaLine® Wall distributor, size A with 4 splice cassettes and 24 strip brushes
LKD 9D71 0009 0000
additional equipment on request
GigaLine® Wall distributor size A
Application
Space-saving distributor cabinets for Fiber-To-The-Office or
Fiber-To-The-Desk cabling systems. Suitable for distributing
up to 24 channels (48 fibers).
Features
For up to 4 splice cassettes with a total of 48 fibers. The buffered
fiber pigtails are inserted, stripped and coloured acc. to the DIN
IEC 60304 colour code (primary and secondary coating) ready
for splicing for fast and reliable installation.
Construction
■■ Powder-coated steel panel, colour Light grey RAL 7035■■ Cable entry from above and below possible■■ 4 cable entries either as M20/M25 or strip brush■■ Door with lock or bolt■■ Weight approx. 4 kg
Dimensions
Size A 300 mm x 300 mm x 85 mm (H x W x D)
Configuration
Optionally only with couplings for pre-assembled trunks,
as splice box or combined
Accessories
Up to 4 splice cassettes
With crimp splice protective holder, buffered fiber strain relief
and cover
Up to 24 couplings: LCD, SCD or E2000
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice 63 GigaLine® FO connectivity
Advantages
■■ space-saving■■ universal use
Designation Order no.
GigaLine® Wall distributor, size B with 12 splice cassettes, 3 strip brushesand an insertion plate
LKD 9D71 0163 0000
additional equipment on request
GigaLine® Wall distributor size B
Application
Space-saving distributor cabinets for Fiber-To-The-Office or
Fiber-To-The-Desk cabling systems. Suitable for distributing
up to 144 channels (288 fibers).
Features
For up to 24 splice cassettes for up to 288 fibers. The buffered
fiber pigtails are inserted, stripped and coloured (primary and
secondary coating) acc. to the DIN IEC 60304 colour code ready
for splicing for fast and secure installation.
Construction
■■ Powder-coated steel panel, colour Light grey RAL 7035■■ Cable entry from above and below possible■■ 4 cable entries either as M20/M25 or strip brush ■■ Door with lock or bolt■■ Weight approx. 7 kg
Dimensions
Size B 600 mm x 425 mm x 220 mm (H x W x D)
Configuration
See distributor A
Accessories
Up to 24 splice cassettes with crimp splice protective holder,
buffered fiber strain relief and cover
or up to 96 ST or LCD couplings
or up to 48 SCD couplings with the corresponding number
of splice cassettes
www.leoni-infrastructure-datacom.com
64GigaLine® FO connectivity
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice 65 GigaLine® FO connectivity
3020 25 35
100
10 000
1
0,01
0,0001
1510
Lebe
nsda
uer (
Jahr
e)
Biegeradius (mm)
25 Jahre
GigaLine® flush-mounted outlet
GigaLine® Fiber-To-The-Desk (FTTD) wall outlets
Compact fiber optic connectivity – high performance, immu-
nity to disturbances, future capabilities
Of course, the GigaLine® system also includes comprehensive
solutions for fiber-to-the-desk. Here it is possible to use a wide
range of wall outlets with the corresponding installation materi-
als for surface mounting and installation in ducts.
As a result of a specific outlet design, bending never goes below
the admissible bending radii of the fibers, thus ensuring that
the fiber keeps its full functionality even in the long term: ■■ A defined bending radius for the fiber ensures the service life■■ An effective strain relief for cables and pigtails and clean
guidance within the outlet ensure minimum strain on the
fiber and preservation of the physical characteristics■■ The dimensions of the outlets are as small as possible
GigaLine® flush-mounted outlet
The flush-mounted outlet can be installed in ducts or,
as the name suggests, mounted flush.
Special features:■■ Can be equipped with up to two duplex or four simplex cou-
plings■■ Possible types of coupling:
SC Duplex, ST Simplex, E 2000, LC Duplex■■ The bending radius of the fiber of at least 30 mm is ensured
by the cable reservoir and the cable guide■■ The outlet has a downward inclination of 10°. This ensures
optimum protection against mechanical stress■■ The universal carrying frame is compatible with usual moun-
ting cups■■ All current connecting techniques are supported:
➔ Assembly of fiber optic plugs on site
➔ Use of pre-assembled cables
➔ Splicing of buffered fiber pigtails
– 5 loops
– 4 loops
– 3 loops
– 2 loops
– 1 loop
www.leoni-infrastructure-datacom.com
66GigaLine® FO connectivity
GigaLine® Wall outlet for surface mounting
Features
Wall outlet for surface mounting.
■■ Downward outlet direction ■■ Splice tray for four splices■■ For 2 SC Duplex or LC Quad couplings■■ Cover with screw as access protection■■ Cable entry for 3–10 mm cables■■ Adherence to the bending radii of approx. 30 mm
thanks to guided fiber paths
Optical characteristics
Insertion loss typ.
Return loss typ.
G50/125 OM3/4 0.2 dB
E9..10/125 OS2 0.2 dB
G50/125 OM3/4 > 35 dB
E9..10/125 OS2 > 50 dB (PC)
> 65 dB (APC)
Dimensions
120 mm x 80 mm x 25 mm (HxWxD)
Accessories
Cable ties, coupling protection, wall mounting set
GigaLine® Wall outlet for flush mounting
Features
Wall outlet for mounting in ducts and for underfloor mounting.
■■ Downward outlet direction (at an angle of 10°)■■ Termination of up to 4 fibers■■ Bending radius > 30 mm in combination with cable reser-
voir KR or cable guide KF■■ Colour: Oyster white RAL 1013
Optical characteristics
Insertion loss typ.
Return loss typ.
G50/125 OM3/4 0.2 dB
E9..10/125 OS2 0.2 dB
G50/125 OM3/4 > 35 dB
E9..10/125 OS2 > 50 dB (PC)
> 65 dB (APC)
Dimensions
114 mm x 85 mm x 41 mm (HxWxD)
Scope of delivery
Equipped with 2 fiber optic couplings
With labelling insert (enclosed)
Designa-tion
ConfigurationOrder no.
OS2 E9..10/125 OM3 G50/125
GigaLine® wall outlet forsurface mounting(1 piece)
SC Duplex Plastic/Cer LKD 9D71 0020 0000 —
SC Duplex Plastic/PhBz — LKD 9D71 0021 0000
LC Quad Plastic/Cer LKD 9D71 0022 0000 —
LC Quad Plastic/PhBz — LKD 9D71 0023 0000
without pigtails
GigaLine® wall outlet forsurface mounting(1 piece)
SC Duplex Plastic/Cer LKD 9D72 0020 0000
SC Duplex Plastic/PhBz LKD 9D72 0021 0000
LC Quad Plastic/Cer LKD 9D72 0022 0000
LC Quad Plastic/PhBz LKD 9D72 0023 0000
Designation Configuration Order no.
GigaLine® wall outlet for flush mounting(1 piece)
2 LC Duplex Plastic/PhBz LKD 9FK0 3026 0000
2 SC Duplex Plastic/PhBz LKD 9FK0 3003 0000
2 SC Duplex Met/Cer LKD 9FK0 3006 0000
4 ST Simplex Met /PhBz LKD 9FK0 3001 0000
GigaLine® FTTD wall outletsfor surface / flush mounting
GigaLine® Cable reservoir KR
Features
For flush-mounted outlet to hold excess cable lengths in
the duct and/or safety reserves (up to 4 x 1 m for an overall
diameter of 3 mm).
■■ Min. bending radius > 30 mm■■ Direction-independent cable entry with cable tie strain relief
on entry and exit side
Dimensions
76 mm x 151 mm x 50 / 55 mm (HxWxD)
50 mm installation depth (KR50), 55 mm installation depth (KR55)
GigaLine® Splice tray for cable reservoir KR
Features
For storing fiber optic splices when splicing plug pigtails.
The separate storage of splice reserve and working reserve
protects the sensitive splice area.
■■ Can be equipped with one or two splice holders for 4 fusion
splices or mechanical splice connectors ■■ Snaps into cable reservoir KR
Designation Order no.
GigaLine® Cable reservoir KR50 (1 piece) LKD 9FK0 3007 0000
GigaLine® Cable reservoir KR55 (1 piece) LKD 9FK0 3008 0000
Designation Order no.
GigaLine® Splice tray for cable reservoir KR (1 piece) LKD 9FK0 3029 0000
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice 67 GigaLine® FO connectivity
GigaLine® FTTD wall outletsCable reservoir / splice tray
www.leoni-infrastructure-datacom.com
68GigaLine® FO connectivity
Designation Configuration Order no.
GigaLine® Outlet EK for cable ducts (1 piece)
1 LC Quad Plastic/PhBz LKD 9FK0 3031 0000
1 SC Duplex Plastic/PhBzr LKD 9FK0 3012 0000
GigaLine® FTTD outlet for cable ductsfor installation in ducts
GigaLine® Outlet EK for cable ducts
Features
Extremely compact outlet for horizontal or vertical installation
in ducts.
Termination of 1 duct/2 fibers.
■■ Outlet direction: Downwards at an angle of 45°,
defined bending radius in conjunction with suitable
mounting bracket MH■■ Strain relief using cable ties■■ Central plate 50 mm x 50 mm
General characteristics
■■ Can be equipped with 1 duplex coupling
or 2 simplex couplings■■ Possible types of coupling: SC Duplex, E 2000, LC Quad■■ The integrated cable guide guarantees adherence to the
minimum bending radius■■ The universal central plate can be combined with various
switch ranges■■ Both cables with pre-assembled plugs
and plugs assembled on site can be used
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice 69 GigaLine® FO connectivity
Designation Order no.
GigaLine® horizontal mounting bracket MH50 (1 piece) LKD 9FK0 3014 0000
GigaLine® horizontal mounting bracket MH55 (1 piece) LKD 9ZK0 3015 0000
GigaLine® vertical mounting bracket MH50 (1 piece) LKD 9FK0 3016 0000
GigaLine® vertical mounting bracket MH55 (1 piece) LKD 9ZK0 3017 0000
Mounting bracket MH for horizontal installation
Mounting bracket MH for vertical installation
GigaLine® FTTD mounting bracket for installation in ductsfor outlet EK for cable ducts
GigaLine® Mounting bracket MH
Features
For space-saving installation of the outlet EK for cable ducts.
The mounting bracket is easy to install and guarantees
adherence to the required bending radii.
■■ Bracket for horizontal or vertical installation with 50 mm
and 55 mm installation depths available
Mounting options
T-slot mounting Horizontal or vertical,
fits ducts from Thealit, OBO/Better-
mann, ASYCO and Alusor
Design
Height 50 mm (MH50)
Height 55 mm (MH55)
www.leoni-infrastructure-datacom.com
70GigaLine® FO patch cords / trunk cables
GigaLine®
FO patch cords / trunk cables
www.leoni-infrastructure-datacom.com
Office DataCenter Industry 71 GigaLine®FO patch cords / trunk cables
GigaLine® FO patch cords / trunk cables page
GigaLine® FO patch cords 72
o ■dc■ Fiber optic patch cord, breakout 72
o ■dc■ Fiber optic patch cord, LC/PC-Uniboot 74
dc■FO patch cords MTP
• MTP I-F(ZN)H 1x12 • MTP I-F(ZN)HH 2x12
75
GigaLine® Trunk – pre-assembled trunk cables 77
o ■dc■ Fiber optic trunk cable, Mini-Breakout 78
o ■dc■ i ■ Fiber optic trunk cable, breakout 80
i ■ Fiber optic trunk cable, outdoor 82
o ■dc■ i ■ Fiber optic trunk cable, universal 84
o ■ Office
dc■ DataCenter
i ■ Industry
www.leoni-infrastructure-datacom.com
72GigaLine® FO patch cords / trunk cables
GigaLine® Patch Figure 0
Construction
Buffered fiber
Strain relief
Cable sheath
Sheath colour
Dimensions
Two semi-tight buffered fibers with strain
relief as breakout elements (diam. 2.1 mm)
running parallel under one outer sheath
Colour: Orange (multimode),
yellow (singlemode)
Aramid
Halogen-free, flame-retardant compound
OM1e, OM2, OM2e ●■Orange
OS2 ●■Yellow
OM3 ●■Aqua
OM4 ●■Heather violet
Outer cable diameter 3.1 x 5.2 mm
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–10 °C up to +70 °C
Mechanical characteristics
Bending radius
(over flat side)
OM1e/2e/OS2 | OM3/4 bendable
static 35 mm | 20 mm
dynamic 65 mm | 35 mm
single element 30 mm | 15 mm
Optical characteristics (typical)
Insertion loss
Return loss
for all fiber types 0.2 dB
G62.5/125 OM1e > 35 dB
G50/125 OM2e > 35 dB
G50/125 OM3 > 35 dB
G50/125 OM4 > 35 dB
E9..10/125 OS2 > 50 dB
E9..10/125 OS2 APC > 65 dB
Fire performanceFlame retardancy
Halogen free
Smoke density
IEC 60332-1 / IEC 60332-3-22, Cat. A
IEC 60754-1
IEC 61034
Breakout patch cord OS2equipped with LC Duplex, SC Duplex, SC Simplex, E-2000 Simplex
GigaLine® Fiber optic patch cord, breakoutType KL-I-V(ZN)HH
Advantages
■■ robust with dual
cable sheath■■ fiber type
recognisable
on the cladding■■ best optical
properties
Outer sheath
Strain relief
Tight buffered fiber
Subcable sheath
Lengthm
OM1eG62.5/125 µm
OM2eG50/125 µm
OM3G50/125 µm
OM4G50/125
OS2E9..10/125
Configuration ST-ST (IEC 61754-2)
1.0 LKD 9A12 0290 0000 LKD 9A11 0238 0000 – – LKD 9A13 0237 0000
1.5 LKD 9A12 0291 0000 LKD 9A11 0239 0000 – – LKD 9A13 0238 0000
2.0 LKD 9A12 0403 0000 LKD 9A11 0240 0000 – – LKD 9A13 0239 0000
2.5 LKD 9A12 0292 0000 LKD 9A11 0241 0000 – – LKD 9A13 0240 0000
3.0 LKD 9A12 0404 0000 LKD 9A11 0242 0000 – – LKD 9A13 0241 0000
5.0 LKD 9A12 0293 0000 LKD 9A11 0243 0000 – – LKD 9A13 0242 0000
7.5 LKD 9A12 0294 0000 LKD 9A11 0244 0000 – – LKD 9A13 0243 0000
10.0 LKD 9A12 0295 0000 LKD 9A11 0245 0000 – – LKD 9A13 0244 0000
Configuration SC Duplex–SC Duplex (IEC 61754-4)
1.0 LKD 9A12 0265 0000 LKD 9A11 0201 0000 LKD 9A11 1042 0000 LKD 9A11 1111 0000 LKD 9A13 0768 0000
1.5 LKD 9A12 0266 0000 LKD 9A11 0202 0000 LKD 9A11 1043 0000 LKD 9A11 1112 0000 LKD 9A13 0769 0000
2.0 LKD 9A12 0256 0000 LKD 9A11 0203 0000 LKD 9A11 1044 0000 LKD 9A11 1113 0000 LKD 9A13 0770 0000
2.5 LKD 9A12 0267 0000 LKD 9A11 0204 0000 LKD 9A11 1045 0000 LKD 9A11 1114 0000 LKD 9A13 0771 0000
3.0 LKD 9A12 0401 0000 LKD 9A11 0205 0000 LKD 9A11 1046 0000 LKD 9A11 1115 0000 LKD 9A13 0772 0000
5.0 LKD 9A12 0402 0000 LKD 9A11 0206 0000 LKD 9A11 1047 0000 LKD 9A11 1116 0000 LKD 9A13 0773 0000
7.5 LKD 9A12 0268 0000 LKD 9A11 0207 0000 LKD 9A11 1048 0000 LKD 9A11 1117 0000 LKD 9A13 0774 0000
10.0 LKD 9A12 0269 0000 LKD 9A11 0208 0000 LKD 9A11 1049 0000 LKD 9A11 1118 0000 LKD 9A13 0775 0000
Configuration LC Duplex–LC Duplex (IEC 61754-20)
1.0 LKD 9A12 0278 0000 LKD 9A11 0220 0000 LKD 9A11 1051 0000 LKD 9A11 1103 0000 LKD 9A13 0759 0000
1.5 LKD 9A12 0279 0000 LKD 9A11 0221 0000 LKD 9A11 1052 0000 LKD 9A11 1104 0000 LKD 9A13 0760 0000
2.0 LKD 9A12 0362 0000 LKD 9A11 0222 0000 LKD 9A11 1053 0000 LKD 9A11 1105 0000 LKD 9A13 0761 0000
2.5 LKD 9A12 0280 0000 LKD 9A11 0223 0000 LKD 9A11 1054 0000 LKD 9A11 1106 0000 LKD 9A13 0762 0000
3.0 LKD 9A12 0281 0000 LKD 9A11 0224 0000 LKD 9A11 1055 0000 LKD 9A11 1107 0000 LKD 9A13 0763 0000
5.0 LKD 9A12 0282 0000 LKD 9A11 0225 0000 LKD 9A11 1056 0000 LKD 9A11 1108 0000 LKD 9A13 0764 0000
7.5 LKD 9A12 0283 0000 LKD 9A11 0226 0000 LKD 9A11 1057 0000 LKD 9A11 1109 0000 LKD 9A13 0765 0000
10.0 LKD 9A12 0284 0000 LKD 9A11 0227 0000 LKD 9A11 1058 0000 LKD 9A11 1110 0000 LKD 9A13 0766 0000
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter 73 GigaLine®FO patch cords / trunk cables
www.leoni-infrastructure-datacom.com
74GigaLine®
GigaLine® Patch LCD-Uniboot OS2GigaLine® Patch LCD-Uniboot OM3GigaLine® Patch LCD-Uniboot OM4
Construction
Cable type
Buffered fiber
Strain relief
Cable sheath
Sheath colour
Cable diameter
KL-I-V(ZN)H
Two semi-tight buffered fibers under a
common sheath (round diam. 2.8 mm)
Aramid
Halogen-free, flame-retardant compound
OM1e, OM2, OM2e ●■Orange
OS2 ●■Yellow
OM3 ●■Aqua
OM4 ●■Heather violet
2.8 mm
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–10 °C up to +70 °C
Mechanical characteristics
Bending radius
Tensile strength
OM1e/2e/OS2 | OM3/4 bendable
static 30 mm | 15 mm
dynamic 60 mm | 30 mm
300 N
Optical characteristics
Insertion loss
Return loss
Laser bandwidth
< 0.4 dB 0.2 dB (typical)
Patch cord OS2 > 50 dB (PC)
> 65 dB (APC)
Patch cord OM3/OM4 > 35 dB
Patch cord OM3 1,500 MHz x km
Patch cord OM4 4,700 MHz x km
Fire performanceFlame retardancy
Halogen free
Smoke density
IEC 60332-1 / IEC 60332-3-22, Cat. A
IEC 60754-1
IEC 61034
ConfigurationLC Duplex Uniboot
KabellängeSee table, other plug types and lengths on request
FO patch cords / trunk cables
GigaLine® Patch LCD-Uniboot
OS2 E9..10/125 GigaLine® Patch LCD-Uniboot
OM3 G50/125 GigaLine® Patch LCD-Uniboot
OM4 G50/125
Lengthm
Configuration 2 x LC Duplex Uniboot Configuration 2 x LC Duplex Uniboot Configuration 2 x LC Duplex Uniboot
1.0 LKD 9A13 0713 0000 LKD 9A11 0866 0000 LKD 9A11 0875 0000
2.0 LKD 9A13 0715 0000 LKD 9A11 0868 0000 LKD 9A11 0877 0000
3.0 LKD 9A13 0717 0000 LKD 9A11 0870 0000 LKD 9A11 0879 0000
5.0 LKD 9A13 0718 0000 LKD 9A11 0871 0000 LKD 9A11 0880 0000
7.5 LKD 9A13 0719 0000 LKD 9A11 0872 0000 LKD 9A11 0881 0000
10.0 LKD 9A13 0720 0000 LKD 9A11 0873 0000 LKD 9A11 0882 0000
Uniboot patch cord OM3 equipped with 2 x LC DuplexUniboot
Uniboot patch cord OM4equipped with 2 x LC DuplexUniboot
Uniboot patch cord OS2equipped with 2 x LC DuplexUniboot
GigaLine® Fiber optic patch cord, LC/PC-UnibootType KL-I-V(ZN)H
Advantages
■■ lowest space
requirements■■ very flexible■■ no preferred
bending direction■■ fiber type
recognisable
on the cladding■■ best optical
properties
www.leoni-infrastructure-datacom.com
Office DataCenter Industry 75 GigaLine®FO patch cords / trunk cablesOffice DataCenter
GigaLine® Patch MTP I-F(ZN)H 1x12 GigaLine® Patch MTP I-F(ZN)HH 2x12
Description
Connection-ready MTP patch cord – assembled
at both ends with one or two MTP plugs (female) or one MTP
(female) to six LC Duplex Uniboot plugs.
Construction
Cable type
Strain relief
Cable sheath
Sheath colour
Cable diameter
KL-I-F(ZN)H 1x1 or
KL-I-F(ZN)HH 2x12
Aramid
Halogen-free, flame-retardant compound
OM2 ●■Yellow | OM3 ●■Aqua |
OM4 ●■Heather violet
3.0 mm (bei 1x12)
8.9 mm (bei 2x12)
Field of application
■■ In DataCenters as a patch cord for applications acc. to
ISO/IEC 11801 and EN 50173 (2nd edition) ■■ GigaLine® Patch MTP–6LCDU (fanout) for multimode applica-
tions via two fibers (up to 10GBASE-SR) ■■ GigaLine® Patch 1MTP–1MTP for multimode applications
via 2 x 4 fibers (40GBASE-SR4) ■■ GigaLine® Patch 2MTP–2MTP for multimode applications
via 2 x 10 fibers (100GBASE-SR10)
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–10 °C up to +70 °C
Mechanical characteristics
Bending radius
KL-I-F(ZN)H 1x12
KL-I-F(ZN)HH 2x12
Single element
Tensile strength
KL-I-F(ZN)H 1x12
KL-I-F(ZN)HH 2x12
OM1e/2e/OS2 | OM3/4 bendable
static 30 mm | 15 mm
dynamic 60 mm | 30 mm
static 90 mm | 45 mm
dynamic 180 mm | 30 mm
see KL-I-F(ZN)H 1x12
300 N
600 N
Optical characteristics (typical)
Insertion loss
Return loss
0.3 dB (MTP) for all fiber types
0.2 dB (LCDU) for all fiber types
OM3/OM4 > 20 dB (MTP)
OM3/OM4 > 40 dB (LCDU)
Fire performanceFlame retardancy
Halogen free
Smoke density
IEC 60332-1 / IEC 60332-3-22, Cat. A
IEC 60754-1
IEC 61034
Designation Configuration side A Configuration side B Order no.Wiring (1:1)
Order no.Wiring(X)
GigaLine® Patch 12
OM3 6 LCD–MTP* 6x LC duplex Uniboot OM3 MTP female 12 OM3 — — LKD 9R72 1xxx 0000KBG00003
OM4 6 LCD–MTP* 6x LC duplex Uniboot OM4 MTP female 12 OM4 — — LKD 9R72 4xxx 0000
OM3 MTP–MTP* MTP female 12 OM3 MTP female 12 OM3 LKD 9R73 6xxx 0000
KBG00005
LKD 9R73 5xxx 0000
KBG00004OM4 MTP–MTP* MTP female 12 OM4 MTP female 12 OM4 LKD 9R73 nxxx 0000 LKD 9R73 3xxx 0000
GigaLine® Patch 2x12
OM3 2xMTP–2xMTP* 2x MTP female 12 OM3 2x MTP female 12 OM3 LKD 9R73 xxxx 0000 LKD 9R7n nxxx 0000
OM4 2xMTP–2xMTP* 2x MTP female 12 OM4 2x MTP female 12 OM4 LKD 9R73 nxxx 0000 LKD 9R73 4xxx 0000
* crossed xxx = Length in m. 1 piece per packing unit.
GigaLine® FO patch cords MTP MTP / MPO patch cordType KL-I-F(ZN)H / KL-I-F(ZN)HH
Advantages
■■ lowest space
requirements■■ very flexible■■ no preferred
bending direction■■ fiber type
recognisable
on the cladding■■ best optical
properties
www.leoni-infrastructure-datacom.com
76GigaLine® FO patch cords / trunk cables
www.leoni-infrastructure-datacom.com
Office DataCenter Industry 77 GigaLine®FO patch cords / trunk cablesOffice DataCenter Industry
GigaLine® Trunk – pre-assembled trunk cablesSafely through "thick and thin"
Ready-to-connect units are at the heart of our fiber optic
system technology. Our pre-assembled cables (GigaLine®
trunk cables) guarantee rapid, reliable and economical instal-
lation. Coordinated system components ensure the quality of
the transmission line. Installations times are calculable.
A lasting solution
On-site installation frequently takes place under unfavoura-
ble conditions. Moisture, dirt and poorly accessible areas are
nothing unusual. This is why we use an IP67 protection class wire
ripple tube for our GigaLine® trunk cables with universal or out-
door cable. Thanks to their particularly strong construction with
an encapsulated cable divider and bolted-on wire ripple tube,
our trunk cables are protected against water spray and non-
crush. They are ideal for harsh construction site environments
and outdoor cabling systems. Indoor cables are fitted with dust
protection without strain relief to prevent soiling of the plugs.
GigaLine® trunk cables ensure that ambient conditions do not
affect the quality of the transmission lines – either during or
after installation. The feeder aid is flexible and has a small cross
section. This enables pre-assembled trunk cables to be easily fed
into tight, twisty manholes and installation channels. A frictional
connection is formed with the divider head. It acts on the strain
relief elements and the sheaths. The fibers thereby remain free
of tension. The divider head design guarantees the stability
of the physical parameters and a long service life.
Time is money
GigaLine® trunk cables stand for reliable and calculable installa-
tion. Installations times are short. All GigaLine® 19" trunk cable
housings have recesses on the back in which the divider head is
mounted to prevent rotation. The fast assembly minimises any
downtime e.g. as a result of an IT system's temporary shutdown.
There is no need for splicing the cables or fitting the plugs on
site, which would sometimes involve adverse conditions. This
also does away with costly outlay on splicing equipment and
specially trained staff. GigaLine® trunk cables can also be used
as a cable pre-assembled at one end.
Fields of application
GigaLine® trunk cables are ideal for backbone cabling in the pri-
mary and secondary segments as well as for collapsed backbone
cabling.
Quality means maximum safety
The plugs are assembled with high quality ceramic ferules
under clean conditions. The plug faces are polished to the high-
est standard, thereby ensuring outstanding plug transitions
in reproducible quality (input and return attenuation). A test
certificate with the attenuation readings of each fiber is sup-
plied with the product. There is also the option of having OTDR
measurements.
www.leoni-infrastructure-datacom.com
78GigaLine® FO patch cords / trunk cables
Optical characteristics
Insertion loss typ.
Return loss typ.
for all fiber types 0.2 dB
G62.5/125 OM1e > 35 dB
G50/125 OM2e > 35 dB
G50/125 OM3 > 35 dB
G50/125 OM4 > 35 dB
E9..10/125 OS2 > 50 dB
E9..10/125 OS2 APC > 65 dB
Mechanical characteristics
Bending radius
OM1e/2e/OS2 | OM3/4 bendable
static 10 | 5 x outer diameter
dynamic 15 | 10 x outer diameter
Fire performance
Flame retardancy
Halogen free
Smoke density
IEC 60332-1 / IEC 60332-3-22, Cat. A
IEC 60754-1
IEC 61034
GigaLine® Trunk Mini-Breakout
Construction
Single elements
Strain relief
Cable sheath
Patch element
Dust protection
Protection class
Up to 12 semi-tight buffered fibers
with diameter 0.9 mm
Colour code acc. to EIA/TIA 598C
Blue (1), orange (2), green (3), brown (4),
grey (5), white (6), red (7), black (8), yellow (9),
violet (10), pink (11), turquoise (12)
Aramid threads
Halogen-free, flame-retardant compound
OM1e, OM2e ●■Orange
OS2 ●■Yellow
OM3 ●■Aqua
OM4 ●■Heather violet
diameter 0.9 mm, shortest patch element
55 cm, gradation 5 cm
Protected with plastic tube
acc. to IP44
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–10 °C up to +50 °C
GigaLine® Fiber optic trunk cable, Mini-BreakoutType KL-I-V(ZN)H, pre-assembled at both ends
Advantages
■■ easy assembly■■ best optical
properties
Plug SC E2000 LC
Singlemode OS2 E9..10/125
4 LKD 9Vxx x08B 0000 LKD 9Vxx x08L 0000 ✆
6 LKD 9Vxx x08C 0000 LKD 9Vxx x08M 0000 ✆
8 ✆ LKD 9Vxx x08N 0000 ✆
12 LKD 9Vxx x08E 0000 LKD 9Vxx x08O 0000 ✆
Multimode OM2e G50/125
4 LKD 9Vxx x095 0000 LKD 9Vxx x09F 0000 ✆
6 LKD 9Vxx x096 0000 LKD 9Vxx x09G 0000 ✆
8 LKD 9Vxx x097 0000 ✆ ✆
12 LKD 9Vxx x098 0000 ✆ ✆
Multimode OM3 G50/125
4 ✆ ✆ ✆
6 ✆ ✆ ✆
8 ✆ ✆ ✆
12 ✆ ✆ ✆
Multimode OM1e G62.5/125
4 LKD 9Vxx x10O 0000 LKD 9Vxx x10Y 0000 ✆
6 LKD 9Vxx x10P 0000 LKD 9Vxx x10Z 0000 ✆
8 ✆ ✆ ✆
12 LKD 9Vxx x10R 0000 LKD 9Vxx x111 0000 ✆
xxx = Length in metres, measured from plug side A to plug side B✆■further plug types and fiber numbers on request
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice DataCenter 79 GigaLine®FO patch cords / trunk cables
www.leoni-infrastructure-datacom.com
80GigaLine® FO patch cords / trunk cables
GigaLine® Trunk Breakout
Construction
Single elements
Strain relief
Cable sheath
Patch element
Dust protection
Protection class
Up to 12 buffered fibers under one sheath,
diameter 2.1 mm
Aramid threads
Halogen-free, flame-retardant compound
OM1e, OM2e ●■Orange
OS2 ●■Yellow
OM3 ●■Aqua
OM4 ●■Heather violet
Shortest patch element 55 cm,
gradation 5 cm
Protected with plastic tube
acc. to IP44
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–10 °C up to +50 °C
Optical characteristics
Insertion loss typ.
Return loss typ.
for all fiber types 0.2 dB
G62.5/125 OM1e > 35 dB
G50/125 OM2e > 35 dB
G50/125 OM3 > 35 dB
G50/125 OM4 > 35 dB
E9..10/125 OS2 > 50 dB
E9..10/125 OS2 APC > 65 dB
Mechanical characteristics
Min. bending radius
OM1e/2e/OS2 | OM3/4 bendable
static 10 | 5 x outer diameter
dynamic 15 | 10 x outer diameter
Fire performance
Flame retardancy
Halogen free
Smoke density
IEC 60332-1 / IEC 60332-3-22, Cat. A
IEC 60754-1
IEC 61034
GigaLine® Fiber optic trunk cable, breakoutType KL-I-V(ZN)HH, pre-assembled at both ends
Advantages
■■ easy assembly■■ best optical
properties
Plug SC E2000 LC
Singlemode OS2 E9..10/125
4 LKD 9Vxx x11D 0000 LKD 9Vxx x11N 0000 ✆
6 ✆ ✆ ✆
8 LKD 9Vxx x11F 0000 LKD 9Vxx x11P 0000 ✆
12 LKD 9Vxx x11G 0000 LKD 9Vxx x11Q 0000 ✆
Multimode OM2e G50/125
4 LKD 9Vxx x127 0000 ✆ ✆
6 ✆ ✆ ✆
8 ✆ ✆ ✆
12 LKD 9Vxx x12A 0000 LKD 9Vxx x12K 0000 ✆
Multimode OM3 G50/125
4 ✆ ✆ ✆
6 ✆ ✆ ✆
8 ✆ ✆ ✆
12 ✆ ✆ ✆
Multimode OM1e G62.5/125
4 LKD 9Vxx x14U 0000 LKD 9Vxx x156 0000 LKD 9Vxx x15I 0000
6 ✆ ✆ ✆
8 LKD 9Vxx x14W 0000 LKD 9Vxx x158 0000 LKD 9Vxx x15K 0000
12 LKD 9Vxx x14Y 0000 LKD 9Vxx x15A 0000 LKD 9Vxx x15M 0000
xxx = Length in metres, measured from plug side A to plug side B✆■further plug types and fiber numbers on request
www.leoni-infrastructure-datacom.com
Office DataCenter Industry 81 GigaLine®FO patch cords / trunk cablesOffice DataCenter Industry
www.leoni-infrastructure-datacom.com
82GigaLine® FO patch cords / trunk cables
GigaLine® Trunk U-DQ(ZN)BH IP67
Construction
Single elements
Farbcode
Strain relief
Cable sheath
Divider head
Strain relief
Patch element
Strain relief
Dust protection
Protection class
Up to 48 buffered fibers with strain relief
under one sheath, diameter 1.8 mm
Acc. to IEC 60304
Non-metallic (glass rovings)
Halogen-free, flame-retardant compound
Colour: black
Aluminium
600 N
Ø 1.8 mm, assorted colours acc. to
IEC 60304, shortest patch element 55 cm,
gradation 5 cm
100 N
Protective tube IP67
Acc. to IP67
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–25 °C up to +70 °C
Optical characteristics
Insertion loss typ.
Return loss typ.
for all fiber types 0.2 dB
G62.5/125 OM1e > 40 dB
G50/125 OM2e > 40 dB
G50/125 OM3 > 40 dB
G50/125 OM4 > 40 dB
E9..10/125 OS2 > 50 dB
E9..10/125 OS2 APC > 70 dB
Size of the divider head
Diameter divider
head max.
Diameter pull tool
max.
for 2–12 fibers 25 mm
for 16–48 fibers 33 mm
for 2–12 fibers 33 mm
for 16–48 fibers 43 mm
Mechanical characteristics
Bending radius static 15 x outer diameter
dynamic 20 x outer diameter
Fire performance
Flame retardancy
Halogen free
Smoke density
IEC 60332-1 / IEC 60332-3-24, Cat. C
IEC 60754-1
IEC 61034
Further characteristics
Longitudinally
watertight
IEC 60794-1-2 F5
GigaLine® Fiber optic trunk cable, universalType KL-U-DQ(ZN)BH, pre-assembled at both ends
Advantages
■■ robust design■■ easy assembly■■ high crush resist-
ance & tensile
strength■■ best optical
properties
www.leoni-infrastructure-datacom.com
Office DataCenter Industry 83 GigaLine®FO patch cords / trunk cables
Plug SC E2000 E2000HRL LC
Singlemode OS2 E9..10/125
4 LKD 9Vxx x61N 0000 LKD 9Vxx x61T 0000 LKD 9Vxx x61Z 0000 LKD 9Vxx x60H 0000
6 LKD 9Vxx x61O 0000 LKD 9Vxx x61U 0000 LKD 9Vxx x620 0000 LKD 9Vxx x60I 0000
8 LKD 9Vxx x61P 0000 LKD 9Vxx x61V 0000 LKD 9Vxx x621 0000 LKD 9Vxx x60K 0000
12 LKD 9Vxx x61Q 0000 LKD 9Vxx x61W 0000 LKD 9Vxx x622 0000 LKD 9Vxx x60L 0000
24 LKD 9Vxx x61R 0000 LKD 9Vxx x61X 0000 LKD 9Vxx x623 0000 LKD 9Vxx x60M 0000
48 LKD 9Vxx x61S 0000 LKD 9Vxx x61Y 0000 LKD 9Vxx x624 0000 LKD 9Vxx x60N 0000
Multimode OM2e G50/125
4 LKD 9Vxx x61G 0000 ✆ ✆ LKD 9Vxx x60B 0000
6 LKD 9Vxx x61H 0000 ✆ ✆ LKD 9Vxx x60C 0000
8 LKD 9Vxx x61I 0000 ✆ ✆ LKD 9Vxx x60D 0000
12 LKD 9Vxx x61K 0000 ✆ ✆ LKD 9Vxx x60E 0000
24 LKD 9Vxx x61L 0000 ✆ ✆ LKD 9Vxx x60F 0000
48 LKD 9Vxx x61M 0000 ✆ ✆ LKD 9Vxx x60G 0000
Multimode OM3 G50/125
4 LKD 9Vxx x61A 0000 ✆ ✆ LKD 9Vxx x615 0000
6 LKD 9Vxx x61B 0000 ✆ ✆ LKD 9Vxx x616 0000
8 LKD 9Vxx x61C 0000 ✆ ✆ LKD 9Vxx x617 0000
12 LKD 9Vxx x61D 0000 ✆ ✆ LKD 9Vxx x618 0000
24 LKD 9Vxx x61E 0000 ✆ ✆ LKD 9Vxx x619 0000
48 LKD 9Vxx x61F 0000 ✆ ✆ LKD 9Vxx x60A 0000
Multimode OM4 G50/125
4 LKD 9Vxx x60U 0000 ✆ ✆ LKD 9Vxx x609 0000
6 LKD 9Vxx x60V 0000 ✆ ✆ LKD 9Vxx x610 0000
8 LKD 9Vxx x60W 0000 ✆ ✆ LKD 9Vxx x611 0000
12 LKD 9Vxx x60X 0000 ✆ ✆ LKD 9Vxx x612 0000
24 LKD 9Vxx x60Y 0000 ✆ ✆ LKD 9Vxx x614 0000
48 LKD 9Vxx x60Z 0000 ✆ ✆ LKD 9Vxx x613 0000
Multimode OM1e G62.5/125
4 LKD 9Vxx x60O 0000 ✆ ✆ ✆
6 LKD 9Vxx x60P 0000 ✆ ✆ ✆
8 LKD 9Vxx x60Q 0000 ✆ ✆ ✆
12 LKD 9Vxx x60R 0000 ✆ ✆ ✆
24 LKD 9Vxx x60S 0000 ✆ ✆ ✆
48 LKD 9Vxx x60T 0000 ✆ ✆ ✆
xxx = Length in metres, measured from plug side A to plug side B✆■further plug types and fiber numbers on request
Office DataCenter Industry
www.leoni-infrastructure-datacom.com
84GigaLine® FO patch cords / trunk cables
GigaLine® Trunk A-DQ(ZN)B2Y IP67
Construction
Single elements
Farbcode
Strain relief
Cable sheath
Divider head
Strain relief
Patch element
Strain relief
Dust protection
Protection class
Up to 48 buffered fibers with strain relief
under one sheath, diameter 1.8 mm
Acc. to IEC 60304
Non-metallic (glass rovings)
PE, UV-resistant
Colour: black
Aluminium
600 N
Shortest patch element 55 cm,
gradation 5 cm
100 N
Protective tube
Acc. to IP67
Thermal characteristics
Transport/storage
Installation
Operating temp.
–25 °C up to +70 °C
–5 °C up to +50 °C
–25 °C up to +70 °C
Optical characteristics
Insertion loss typ.
Return loss typ.
for all fiber types 0.2 dB
G62.5/125 OM1e > 35 dB
G50/125 OM2e > 35 dB
G50/125 OM3 > 35 dB
G50/125 OM4 > 35 dB
E9..10/125 OS2 > 50 dB
E9..10/125 OS2 APC > 65 dB
Size of the divider head
Diameter divider
head max.
Diameter pull tool
max.
for 2–12 fibers 25 mm
for 16–48 fibers 33 mm
for 2–12 fibers 33 mm
for 16–48 fibers 43 mm
Mechanical characteristics
Bending radius static 15 x outer diameter
dynamic 20 x outer diameter
Fire performance
Halogen free IEC 60754-1
sonstige Eigenschaften
Longitudinally
watertight
IEC 60794-1-2 F5
GigaLine® Fiber optic trunk cable, outdoorType KL-A-DQ(ZN)B2Y, pre-assembled at both ends
Advantages
■■ robust design■■ easy assembly■■ high crush resist-
ance & tensile
strength■■ best optical
properties
Plug SC E2000 E2000HRL LC
Singlemode OS2 E9..10/125
4 LKD 9Vxx x005 0000 LKD 9Vxx x00J 0000 LKD 9Vxx x00Q 0000 ✆
6 LKD 9Vxx x006 0000 LKD 9Vxx x00K 0000 LKD 9Vxx x00R 0000 ✆
8 LKD 9Vxx x007 0000 LKD 9Vxx x00L 0000 LKD 9Vxx x00S 0000 ✆
12 LKD 9Vxx x008 0000 LKD 9Vxx x00M 0000 LKD 9Vxx x00T 0000 ✆
16 LKD 9Vxx x009 0000 LKD 9Vxx x00N 0000 LKD 9Vxx x00U 0000 ✆
24 LKD 9Vxx x00A 0000 LKD 9Vxx x00O 0000 LKD 9Vxx x00V 0000 LKD 9V10 0647 0000
48 LKD 9Vxx x00B 0000 LKD 9Vxx x00P 0000 LKD 9Vxx x00W 0000 LKD 9Vxx x01A 0000
Multimode OM2e G50/125
4 LKD 9Vxx x01B 0000 LKD 9Vxx x01P 0000 ✆ LKD 9Vxx x023 0000
6 LKD 9Vxx x01C 0000 LKD 9Vxx x01Q 0000 ✆ ✆
8 LKD 9Vxx x01D 0000 ✆ ✆ LKD 9Vxx x025 0000
12 LKD 9Vxx x01E 0000 ✆ ✆ LKD 9Vxx x026 0000
16 ✆ ✆ LKD 9Vxx x027 0000
24 LKD 9Vxx x01G 0000 ✆ ✆ LKD 9Vxx x028 0000
48 LKD 9Vxx x01H 0000 ✆ ✆ LKD 9Vxx x029 0000
Multimode OM3 G50/125
4 ✆ ✆ ✆ ✆
6 ✆ ✆ ✆ ✆
8 ✆ ✆ ✆ ✆
12 LKD 9V10 062A 0000 ✆ ✆ LKD 9Vxx x62J 0000
16 ✆ ✆ ✆ ✆
24 ✆ ✆ ✆ LKD 9Vxx x65G 0000
Multimode OM1e G62.5/125
4 LKD 9Vxx x03G 0000 LKD 9Vxx x03U 0000 ✆ ✆
6 LKD 9Vxx x03H 0000 LKD 9Vxx x03V 0000 ✆ ✆
8 LKD 9Vxx x03I 0000 LKD 9Vxx x03W 0000 ✆ ✆
12 LKD 9Vxx x03J 0000 LKD 9Vxx x03X 0000 ✆ ✆
16 ✆ ✆ ✆ ✆
24 LKD 9Vxx x03L 0000 LKD 9Vxx x03Z 0000 ✆ ✆
xxx = Length in metres, measured from plug side A to plug side B✆■further plug types and fiber numbers on request
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryIndustry 85 GigaLine®FO patch cords / trunk cables
www.leoni-infrastructure-datacom.com
86GigaLine® DataCenter links
GigaLine®
DataCenter links
www.leoni-infrastructure-datacom.com
Office DataCenter Industry 87 GigaLine®DataCenter links
GigaLine® DataCenter links page
GigaLine® DataCenter links 88
dc■ DataCenter link• DClink 40/100 OM3 G50/125• DClink 40/100 OM4 G50/125
89
dc■ DataCenter link• DClink OS2 E9.10/125• DClink OM3 G50/125• DClink OM4 G50/125
91
dc■ DataCenter MTP module• DC MTP module OS2 E9..10/125• DC MTP module OM3 G50/125• DC MTP module OM4 G50/125
91
o ■ Office
dc■ DataCenter
i ■ Industry
www.leoni-infrastructure-datacom.com
88GigaLine® DataCenter links
GigaLine® DataCenter linksQuick & easy solution for ready-to-use links in DataCenters
For transmissions up to 10 Gbit/s, fiber pairs are separated from
the 12x fiber bundle using an MPO to LC duplex fanout (see
Figure) so that 144 channels are available per rack unit.
To retrofit the system for 40 Gbit/s systems (parallel transmission
over 2 x 4 fibers), the fanout simply has to be replaced by sim-
plex MPO patch cords (see Figure) with 12 fibers (24 systems per
rack unit).
Two simplex MPO patch cords, i.e. 2x12 fibers (parallel transmis-
sion over 2 x 10 fibers) are used for 100 Gbit/s (12 systems per
rack unit).
In contrast to conventional cabling systems in which the link
has to be replaced, GigaLine® DClink offers numerous advan-
tages:■■ Migratability to all data rates used is possible by simply
replacing the patch cords (no need to modify the permanent
installation)■■ Rapid and economical installation as GigaLine® DClink is deli-
vered fully assembled■■ High reliability and quality as GigaLine® DClink is tested
before leaving the factory■■ Clear arrangement in spite of high packing density
DataCenters have special requirements since downtimes
there can have catastrophic consequences.
It must therefore be ensured that disruptions are kept to
a minimum, particularly when carrying out renovation work
during operation. LEONI has developed systems for this that
take these requirements into consideration right from the
construction stages of a new DataCenter.
As well as ensuring adherence to the applicable cabling stan-
dards, our systems also offer countless options for quick and
reliable construction and renovation of DataCenters.
DClink 40/100 is a cabling system that is suitable for all trans-
mission protocols. It is delivered as a tested permanent FO link
and consists of a cable with 8x12 OM3/OM4 fibers that is already
equipped with a partial patch panel at both ends. The pre-
assembled link just has to be installed by snapping it into the
socket provided in the patch panel. This allows three GigaLine®
DClink partial patch panels with 8 MPO couplings each in the
patch panel to be fitted at a single level.
The use of low or medium data rates of up to 10 Gbit/s and
higher data rates of up to 40 and 100 Gbit/s can thus be realised
without modifications to the permanently installed GigaLine®
DClink cabling. This allows the fibers to be used both individu-
ally for applications up to 10 Gbit/s and in parallel for 40 and 100
Gbit/s. Migration or connection to the necessary transmission
technology is carried out via application-specific patch cords.
VarioLine® DClink sockets with 3 GigaLine® DClink modules 40/100 Gbit/s with 8 MPO each
GigaLine® patch cord MPO-6LC-Dx (fanout)
GigaLine® patch cord MPO-MPO (12 OM3/OM4)
Configuration Order no.
GigaLine® DClink OM3 G50/125 GigaLine® DClink OM4 G50/125
8 MTP(male) – 8 MTP(male) LKD 9R31 6xxx 0000* LKD 9R31 nxxx 0000*
xxx = Length between the link modules in m. Further configurations on request.1 piece per packing unit.
* Wiring: crossed (KBG00007)
Designation Cable type ColourLaser bandwidth
Strain relief
Cable sheathSheath diameter
MHz x km N mm
GigaLine® DClink 40/100 OM3KL-I-F(ZN)H(ZN)H 8x12 24 G50/125 2,5B1500 0,7F500(IEC 60793-2 A1a.2)
Aqua 2,0001,000
Halogen-free and flame-retardant
14.0GigaLine® DClink 40/100 OM4
KL-I-F(ZN)H(ZN)H 8x12 24 G50/125 2,5B3500 0,7F500(IEC 60793-2 A1a.3)
Heather violet
2,000
GigaLine® DClink 40/100 OM3 G50/125GigaLine® DClink 40/100 OM4 G50/125
Description
Connection-ready link – one DClink module in a high tensile
strength connection with a high-quality universal cable at each
end. The housing can be opened if necessary and the divider
containing the patch elements removed and pulled through
tight openings (≥ diam. 35 mm) with the help of a pull-in tube.
Field of application
In DataCenters acc. to ISO/IEC 11801 and EN 50173 (2nd edition).
DClink OS3
DClink OM4
For all applications from Classes >
OF-100(40 and 100 GBE),
OF-300 (10 GbE),
OF-500 (GbE/Fiber Channel)
and OF-2000 (Fast Ethernet)
For all applications from Classes >
OF-100(40 and 100 GBE),
OF-300 (GigaLine 550), (10 GbE),
OF-500 (GbE/FiberChannel)
and OF-2000 (Fast Ethernet)
DClink-Modul
Housing
Dimensions
Configuration
Insertion loss
Return loss
Steel panel, front Jet black RAL 9005
40 mm x 135 mm x 150 mm (HxWxD)
8 MTP / MPO
0.25 dB (typ.)
OM3 > 20 dB
OM4 > 20 dB
Accessories (optional)
GigaLine® DClink Pull tool
Order no.: LKD 9R00 0008 0000
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryDataCenter 89 GigaLine®DataCenter links
GigaLine® DataCenter linkConnection-ready links up to 100 Gbit/s
Advantages
■■ for all data rates
up to 100 Gbit/s■■ highest degree of
preassembly■■ simplest assembly■■ best optical
properties
www.leoni-infrastructure-datacom.com
90GigaLine® DataCenter links
Configuration Order no.
GigaLine® DClink OS2 E9..10/125 GigaLine® DClink OM3 G50/125 GigaLine® DClink OM4 G50/125
6 LC Duplex PC – 6 LC Duplex PC* LKD 9R20 8xxx 0000 LKD 9R30 8xxx 0000 LKD 9R10 8xxx 0000
6 LC Duplex PC – 6 SC Duplex PC* LKD 9R20 9xxx 0000 LKD 9R30 9xxx 0000 LKD 9R10 9xxx 0000
6 SC Duplex PC – 6 SC Duplex PC* LKD 9R21 0xxx 0000 LKD 9R31 0xxx 0000 LKD 9R11 0xxx 0000
12 LC Duplex PC – 12 LC Duplex PC* LKD 9R21 1xxx 0000 LKD 9R31 5xxx 0000 LKD 9R11 1xxx 0000
12 E2000-Simplex PC – 12 E2000 Simplex PC* LKD 9R21 2xxx 0000 LKD 9R31 2xxx 0000 LKD 9R11 2xxx 0000
6 LC Duplex PC – 12 E2000 Simplex PC* LKD 9R21 3xxx 0000 LKD 9R31 3xxx 0000 LKD 9R11 3xxx 0000
*Wiring: crossed in pairs (KBG00001)xxx = Length between the link modules in m. Other configurations on request.1 piece per packing unit.
Designation Cable typeLaser bandwidth
Strain relief
Cable sheathSheath diam.
MHz x km N mm
GigaLine® DClink OS2 KL-U-DQ(ZN)BH 1x12 or 24 E9/125 0,36F3,5/0,22H18 (ITU G652.D) –
1,000Halogen-free and flame-retardant
7.0 (12 fibers) 7.5 (24 fibers)
GigaLine® DClink OM3 KL-U-DQ(ZN)BH 1x12 or 24 G50/125 2,5B1500 0,7F500 (IEC 60793-2 A1a.2) 2,000
GigaLine® DClink OM4 KL-U-DQ(ZN)BH 1x12 or 24 G50/125 2,5B3500 0,7F500 (IEC 60793-2 A1a.3) 4,700
GigaLine® DClink OS2 E9.10/125GigaLine® DClink OM3 G50/125GigaLine® DClink OM4 G50/125
Description
Connection-ready link – one DClink module in a high tensile
strength connection with a high-quality universal cable at each
end. The housing can be opened if necessary and the divider
containing the patch elements removed and pulled through
tight openings (≥ diam. 35 mm) with the help of a pull-in tube.
Field of application
In DataCenters acc. to ISO/IEC 11801 and EN 50173 (2nd edition).
DClink OS2
DClink OM3
DClink OM4
For all applications up to Class OF-10000
For all applications from Classes
OF-300 (10 GbE), OF-500 (GbE/Fiber
Channel) and OF-2000 (Fast Ethernet)
For all applications from Classes >
OF-300 (GigaLine 550), (10 GbE),
OF-500 (GbE/ FiberChannel)
and OF-2000 (Fast Ethernet)
DClink-Modul
Housing
Dimensions
Configuration
Insertion loss
Return loss
Steel panel, front Jet black RAL 9005
40 mm x 135 mm x 150 mm (HxWxD)
Fiber optic connector (see table)
0.2 dB (typ.)
OS2 > 50 dB (PC), > 70 dB (APC)
OM3 > 40 dB
OM4 > 40 dB
Accessories (optional)
GigaLine® DClink Pull tool Order no.: LKD 9R00 0008 0000
GigaLine® DataCenter linkConnection-ready links
Advantages
■■ for all data rates
up to 10 Gbit/s■■ highest degree
of preassembly■■ simplest assembly
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryDataCenter 91 GigaLine®DataCenter links
Designation Configuration Order no. Configuration Order no.
1 x GigaLine® MTP module OS2 E9..10/125 6 LC Duplex PC* LKD 9R70 0008 0000 6 LC Duplex PC** LKD 9R7G 0008 0000
2 x GigaLine® MTP module OS2 E9..10/125 12 LC Duplex PC* LKD 9R70 0009 0000 12 LC Duplex PC** LKD 9R7G 0009 0000
1 x GigaLine® MTP module OM4 G50/125 6 LC Duplex PC* LKD 9R70 0010 0000 6 LC Duplex PC** LKD 9R7G 0010 0000
2 x GigaLine® MTP module OM4 G50/125 12 LC Duplex PC* LKD 9R70 0011 0000 12 LC Duplex PC** LKD 9R7G 0011 0000
1 x GigaLine® MTP module OM3 G50/125 6 LC Duplex PC* LKD 9R70 0012 0000 6 LC Duplex PC** LKD 9R7G 0012 0000
2 x GigaLine® MTP module OM3 G50/125 12 LC Duplex PC* LKD 9R70 0013 0000 12 LC Duplex PC** LKD 9R7G 0013 0000
1 piece per packing unit. * Wiring: crossed (KBG00003) ** Wiring: crossed / twisted in pairs (KBG00006)
GigaLine® DC MTP module OS2 E9..10/125GigaLine® DC MTP module OM3 G50/125GigaLine® DC MTP module OM4 G50/125
Description
Connection-ready MTP module for installation in a DClink frame.
Field of application
In DataCenters and in structured cabling acc. to ISO/IEC 11801
and EN 50173 (2nd edition).
For all applications from Classes >OF-300 (GigaLine 550)
(10 GbE), OF-500 (GbE/FiberChannel) und OF-2000 (Fast
Ethernet).
DC MTP module
Housing
Dimensions
Front side
Configuration
Insertion loss
Return loss
Rear
Configuration
Insertion loss
Return loss
Fiber types
Steel panel, front Jet black RAL 9005
40 mm x 135 mm x 150 mm (HxWxD)
max. 12 LC Duplex, 6 SC Duplex,
12 SC-Simplex, 12 E-2000 Simplex
typ. 0.2 dB
> 50 dB (SM, PC), > 65 dB (SM, APC),
> 35 dB (MM)
1x or 2x MTP® (male)
typ. 0.3 dB
> 50 dB (SM), > 20 dB (MM)
OS2 / OM4 / OM3
GigaLine® DataCenter MTP modulefor installation in DClink frame
www.leoni-infrastructure-datacom.com
92GigaLine®
www.leoni-infrastructure-datacom.com
Office DataCenter Industry 93 GigaLine®
The acceptance measurement for GigaLine® cabling systems
is carried out in accordance with the requirements of ISO/IEC
11801 or EN 50173-1:2007. DIN ISO/IEC 14763-3 is also relevant
to the acceptance measurement.
For an OTDR measurement, a launch fiber and receive fiber
must be used. These must be longer than the dead zone of the
OTDR being used. For multimode links, the fiber should be at
least 100 m in length; for singlemode links, the fiber should be
at least 500 m in length.
A bidirectional measurement is necessary to avoid or eliminate
measurement errors due to different backscatter coefficients
if the overall link consists of several spliced or patched sublinks.
The set measuring range must be twice as big as the transmis-
sion link to be measured. The pulse width of the OTDR should
be chosen as short as possible. This keeps the dead zones at
reflected events to a minimum.
Index-adjusting materials must not be used.
Maximum attenuation of the transmission links in dB
Class Multimode Singlemode
850 nm 1,300 nm 1,310 nm 1,550 nm
OF 300 2.55 1.95 1.80 1.80
OF 500 3.25 2.25 2.00 2.00
OF 2000 8.50 4.50 3.50 3.50
OF 5000 4.00 4.00
OF 10000 6.00 6.00
Both attenuation meters and OTDR are vital for professional fiber
optic installation. The test engineer must have a valid calibration
certificate for the testing device.
Attenuation meters OTDR Fiber identifiers
Acceptance measurementfor GigaLine® cabling systems
www.leoni-infrastructure-datacom.com
Field of application94
OfficeField of application
www.leoni-infrastructure-datacom.com
Office DataCenter IndustryOffice Field of application 95
CD Campus distributor
EI Building distributor
FD Floor distributor
CP Consolidation point
TO Telecommunications outlet
TE Terminal equipment
Structure of a generic communication cable system ISO/IEC 11801 and DIN EN 50173-1/2
FDEI CP TO TECD
Subsystem of the primary cabling system
Subsystem of the secon-dary cabling
system
Subsystem of the tertiary cabling system
Generic communication cable system
Equipment connection
cabling system
These days, the future of a company depends to a large
extent on reliable and timely data processing.
The rapid development of data bit rates and the wide range of
applications require a very flexible, high-performance network
infrastructure that will be able to meet the demands for the
next ten years.
High-quality generic IT networks form the backbone of the busi-
ness in research & development, banks, insurance companies,
universities, hospitals, hotels, airports and many other sectors,
providing smooth operation and financial success.
The smart use of fiber optics and copper data technologies for
the backbone and horizontal wiring to the user enables cost-
effective networking of standard resources such as PCs and
printers, with an extension to IP telephony and multimedia
applications. Other applications, such as Power-over-Ethernet
(PoE), support the powering of devices such as web cameras,
wireless LAN access points, IP phones and laptops via the copper
data cabling.
These structured, generic communication cable systems meet
both the international and European standards set by ISO/IEC
11801 and DIN EN 50173-1/2 respectively.
Generic cabling in office buildingsThe complete cable system, from distribution equipment to workstation
ISO/IEC 11801 and EN 50173-2
Information technology
Genericcommunication cable systems
Office buildings
ISO/IEC 11801 andEN 50173-1
Information technology
Genericcommunication cable systems
General requirements
ISO/IEC 24702 andEN 50173-3
Information technology
Genericcommunication cable systems
Industry
ISO/IEC 15018 andEN 50173-4
Information technology
Genericcommunication cable systems
Apartments
ISO/IEC 24764 andEN 50173-5
Information technology
Genericcommunication cable systems
DataCenters
www.leoni-infrastructure-datacom.com
Field of application
DataCenterField of application
96
www.leoni-infrastructure-datacom.com
Office DataCenter Industry Field of applicationDataCenter 97
Generic cabling in DataCenters
The structure
The maximum extension is 2,000 metres. In DataCenters the
main distribution cabling is frequently designed using fiber
optic technology, while in smaller networks the external net-
work interface (ENI) is connected directly to the zone distributor
(ZD). The standards describe various models for flexible and
fixed connections in and between the subsystems.
The cabling of the main and zone distribution must, according
to ISO/IEC 24764, meet the requirements of Class EA for copper
technology and transmission classes OF-300, OF-500 and
OF-2000 for fiber optic technology as a minimum.
The standards
Generic communication cable systems are defined in the stan-
dards EN 50173-1 and ISO/IEC 11801.
In addition, specific requirements for DataCenters are defined
in EN 50173-5 and ISO/IEC 24764.
The cabling used in DataCenters consists of three subsystems:■■ Network access cabling ■■ Main distribution cabling ■■ Zone distribution cabling
ENI External network interface
MD Main distributor
ZD Zone distributor
LDP Local distribution point
(optional)
EO External network interface
EQP Application-specific
transmission equipment
Structure of a generic communication cable system
ZDMD LDP EO EQPENI
Distributor acc. to
EN 50173-1
ISO/IEC 11801 and EN 50173-2
Information technology
Generic communication cable systems
Office buildings
ISO/IEC 11801 andEN 50173-1
Information technology
Generic communication cable systems
General requirements
ISO/IEC 24702 andEN 50173-3
Information technology
Generic communication cable systems
Industry
ISO/IEC 15018 andEN 50173-4
Information technology
Generic communication cable systems
Apartments
ISO/IEC 24764 andEN 50173-5
Information technology
Generic communication cable systems
DataCenters
Networkaccess
Main distribution
cablingZone distribution cabling
Generic communication cable system
Equipmentcabling
www.leoni-infrastructure-datacom.com
Field of application98
DataCenter
The DataCenter, the heart of the business, controls the pro-
duction and administrative processes. A failure here can have
catastrophic consequences, and the availability of a DataCenter
must be therefore guaranteed more or less around the clock.
The cabling system makes a key contribution to its operation
reliability.
Performance requirements for modern DataCenters■■ Maximum availability, zero downtime ➔ maximum reliability■■ Short installation times■■ Maximum performance■■ Minimal space requirement – high packing density■■ Cost efficiency■■ Environmental compatibility – Green IT
The diverse requirements for DataCenters cannot be considered
separately. For example, optimising the environmental perfor-
mance will lead to a reduction in costs. Investing in industrially
pre-assembled components is usually associated with higher
costs, but enables installation and testing times to be reduced,
thus reducing the cost associated with downtime.
➔ High quality
Quality testing at the factory, performance and safety are
already built into LEONI products.
➔ Minimise downtime
Installation and commissioning take a very short time, with
no need for special tools or assembly skills. This keeps down-
time to a minimum.
➔ Cost reduction
The use of GigaLine® DClink results
in cost savings of up to 55 % in
comparison with traditional modular
systems using MPO connection
technology.
Requirements and solutionsFast – high-quality – cost-optimised
Costs per link*
100 %
45 %
Mod
ular
solu
tion
s wit
h M
PO
DCl
ink
* Example: Link length: 30 m, fibers: 24 x OS2, plugs: LC Duplex
www.leoni-infrastructure-datacom.com
Office DataCenter Industry Field of applicationDataCenter 99
Ecologically aware cabling
Environmentally sound materials and production methods,
the possibility of recycling or ecologically viable recovery and,
last but not least, the reusability of products if required guaran-
tee maximum environmental compatibility. Cables and compo-
nents are free of hazardous substances.
Optimising attenuation
A GigaLine® DClink offers up to 70 %
less attenuation than conventional
modular systems using MPO
connectivity.
GigaLine ® DClink
VarioLine ® CP
GigaLine ® DCflex
MegaLine ® DClink
LEONI can offer a range of high-
quality products that go well beyond the
current standards and requirements for data centers.
■■ An EC7 plug and the corresponding cable delivers
performance far exceeding Class FA ■■ Fiber optic cable systems constructed using LEONI cables
offer enormous reserves for attenuation and bandwidth
The Installation
Plug and play solutions for copper and fiber optic applica-
tions consist of pre-assembled links and the VarioLine® DClink
frame (19", 1 RU) for the DClink modules. The DClink modules
are simply inserted and clicked into place from the rear after
the links are installed.
DClink system solutions
DClink can be used to create fiber optic, copper or mixed con-
figurations in various categories. This renders on-site assembly
completely unnecessary. The modules can be easily removed
again using a simple release tool.
Attenuation per link*
IL=1.4 dB100 %
IL=0.4 dB> 30 %
Mod
ular
solu
tion
s wit
h M
PO
DCl
ink
* Example: Link length: 30 m, fibers: 24 x OS2, plugs: LC Duplex
The advantagesExceed all requirements with LEONI
www.leoni-infrastructure-datacom.com
Field of application100
Single cables – complex installation and cannot be reused
It is not just installing new cables that is difficult and time-
consuming, but also removing the old cables. The only options
are either to cut them out or simply leave them where they are.
This means that there is no practical way of reusing them and
they are not recycled.
The disorganised way in which the cables are installed obstructs
the flow of cooling air. Only a higher volumetric flow rate and/or
a lower air temperature can help here. Both mean higher costs
and increased environmental impact.
Comparison of cabling systemsSingle cable vs. multi cable
www.leoni-infrastructure-datacom.com
101
Multi cables – quick and clean installation and can be reused at any time
Pre-assembled multi cable solutions ensure a clean and clear
cabling layout in the raised floor. As well as making installation
easier and therefore quicker, this also helps to improve cooling
air circulation.
Cables and components are free of hazardous substances.
The low volume of the installed multi cables guarantees an
unobstructed flow of cooling air and therefore uses less energy.
Index
Welcome to the mega store for cable and system solutions
2
The LEONI Group 4
High-quality industrial cables and conductors
5
Great brands, great service 6
Green Technology 8
Technologies – investment in sustainable security
10
GigaLine® FO data cables 12
The fiber 14
For LAN, WAN and SAN 17
Fiber qualities 18
Colour codes 19
Type codes 20
Jacketing material for optical cables 21
Rodent protection for fiber optic cables 22
Pictograms 23
Handling and safety notices 24
GigaLine® Indoor cable, duplex fig 8 25
GigaLine® Indoor cable, duplex fig 0 26
GigaLine® Indoor cable, Mini-Breakout 27
GigaLine® Breakout cable 28
GigaLine® Universal cable, Mini-Breakout 800 N
29
GigaLine® Universal cable, central 2500 N
30
GigaLine® Universal cable, stranded 4000 N
31
GigaLine® Universal cable, central 2500 N
32
LEONI „fire secured“ FO data cables 33
GigaLine® „fire secured“ universal cable, central with CI, 90 min system integrity
34
GigaLine® „fire secured“ universal cable, central with CI, 120 min system integrity
35
GigaLine® Outdoor cable, central 1750 N 36
GigaLine® Outdoor cable, stranded 4000 N
37
GigaLine® Outdoor cable, central 1750 N 38
GigaLine® Outdoor cable, stranded 4000 N
39
GigaLine® Outdoor cable, stranded with sheath, 4000 N
40
GigaLine® FO connectivity 42
FO cabling systems 44
GigaLine® Trunk and splice boxes 47
Fiber optic trunk box 48
Fiber optic splice box, telescopic 50
Fiber optic splice box, fixed 52
GigaLine® Compact – fiber optic distribution system
55
Compact fiber optic rack 56
Compact fiber optic module 57
Compact fiber optic module, for splicing solutions
58
GigaLine® Office and floor distributors 61
Fiber optic office and floor distributors 62
GigaLine® Fiber-To-The-Desk (FTTD) wall outlets
65
FTTD wall outlets for surface / flush mounting
66
FTTD wall outlets Cable reservoir / splice tray
67
FTTD outlet for cable ducts 68
FTTD mounting bracket for cable ducts 69
GigaLine® FO patch cords / trunk cables
70
Fiber optic patch cord, breakout 72
FO patch cords LC/PC-Uniboot 74
FO patch cords MTPMTP / MPO patch cord
75
GigaLine® Trunk – pre-assembled trunk cables
77
Fiber optic trunk cable, Mini-Breakout 78
Fiber optic trunk cable, breakout 80
Fiber optic trunk cable, universal 82
Fiber optic trunk cable, outdoor 84
GigaLine® DataCenter links 86
DataCenter links 88
DataCenter link up to 100 Gbit/s 89
DataCenter link, connection-ready 90
DataCenter link MTP module 91
GigaLine® Acceptance measurement 93
Office – Field of application 94
Generic cabling in office buildings 95
DataCenter – Field of application 96
Generic cabling in DataCenters 97
Requirements and solutions 98
The advantages 99
Comparison of cabling systems 100
www.leoni-infrastructure-datacom.com
102GigaLine®
LEONI news
Additional catalogues for MegaLine® copper systems
and VarioLine® connection systems available online at
www.leoni-infrastructure-datacom.com.
Our regularly updated information services such as the LEONI
newsletter keep you abreast of recent developments at LEONI
and on the market.
Visit our homepage:
www.leoni-infrastructure-datacom.com
Here you will find the latest information ■■ Product and company news■■ Specialist articles■■ Trade fairs, seminars and roadshows■■ Announcement texts■■ Standardisations/certification programmes
www.leoni-infrastructure-datacom.com
Office DataCenter Industry 103 GigaLine®
03. 20
14 / en
_500
0
LEONI Kerpen GmbH
Zweifaller Strasse 275–287
52224 Stolberg
Germany
Phone +49 (0) 2402 17 1
Fax +49 (0) 2402 75154
E-Mail [email protected]
LEONI Studer AG
Herrenmattstrasse 20
4658 Däniken
Switzerland
Phone +41 (0)62 288 82 82
Fax +41 (0)62 288 83 83
E-Mail [email protected]
Find out more:
Business Unit Infrastructure & Datacomwww.leoni-infrastructure-datacom.com