Geothermal For Commercial Buildings

96
So called global warming is just a secret plot by wacko tree huggers to make America energy independent, clean our air and water, improve the fuel efficiency of our vehicles, kick start 21 st century industries and make our cities safer and more livable. Dont let them get away with it. Chip Giller, Grist.Org

description

During this seminar we will discuss the design and operational characteristics of a geothermal HVAC system. We will explore the different configurations of a geothermal system including standing column, horizontal loop, vertical loop and pond loop systems. We will compare geothermal HVAC systems with conventional HVAC systems relative to first costs, operating costs, functionality and maintenance focusing on commercial buildings. Learning Objectives: -Develop an understanding of how a geothermal heat pump system operates. -Have the ability to assess if a building is a candidate for a geothermal heat pump system. -Understand the environmental, operational and cost benefits of a geothermal heat pump system.

Transcript of Geothermal For Commercial Buildings

Page 1: Geothermal For Commercial Buildings

So called global warming is just a secret plot by wacko tree huggers to make America energy independent, clean our air and water, improve the fuel efficiency of our vehicles, kick start 21st century industries and make our cities safer and more livable. Don’t let them get away with it.

Chip Giller, Grist.Org

Page 2: Geothermal For Commercial Buildings

Geothermal Systemsfor

Commercial Buildings

Geothermal Systemsfor

Commercial Buildings

Page 3: Geothermal For Commercial Buildings

Presenters:

Brian Smith, PE, LEED APPrincipal, Allied Consulting Engineering Services

Steve Sakakeeny, CPG, LSP, CHMM Principal, SAK Environmental

D.J. Quagliaroli President, DRAGIN Geothermal Well Drilling

Page 4: Geothermal For Commercial Buildings

Allied Consulting Engineering Services, Inc. is a Registered Provider with the American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to CES Records for AIA members. Certificates of Completion for non-AIA members are available on request.

This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing an any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation.

Page 5: Geothermal For Commercial Buildings

Copyright Materials

This presentation is protected by US and International copyrightlaws. Reproduction, distribution, display and use of the presentation without written permission of the speaker is prohibited.

©2009 Allied Consulting Engineering Services, Inc.

consulting engineering services, inc.

Page 6: Geothermal For Commercial Buildings

Develop an understanding of how a geothermal heat pump system operates.Have the ability to assess if a building is a candidate for a geothermal heat pump system, including technical and regulatory obstacles.Understand the environmental, operational and cost benefits of a geothermal heat pump system.

L

E

A

R

N

I

N

G

O

B

J

E

C

T

I

V

E

S

Page 7: Geothermal For Commercial Buildings

H

O

R

I

Z

O

N

T

A

LL

O

O

P

Loops are installed in trenches 5-10 feet below surface.

Requires 2,500 square feet per ton of cooling.

Generally installed in areas with moist sand or dirt.

Must understand hydrology.

Page 8: Geothermal For Commercial Buildings

V

E

R

T

I

C

A

L

L

O

O

P

Boreholes are drilled several hundred feet deep.

Requires 200-250 linear feet per ton of cooling.

Page 9: Geothermal For Commercial Buildings

Geothermal loop is installed directly into a pond or other body of water near the building.

Size and depth of pond must be analyzed to ensure sufficient capacity.

Man made ponds/lakes are often installed to accommodate a pond loop simultaneously adding to the aesthetics of the property.

P

O

N

D

L

O

O

P

Page 10: Geothermal For Commercial Buildings

Wells are drilled 1,000 – 1,500 feet deep.

Generally installed in areas with shallow bedrock (within 200’)

Heat transfer medium (water) comes into direct contact with heat sink/source (rock), resulting in higher efficiency than closed systems.

S

T

A

N

D

I

N

G C

O

L

U

M

N

Page 11: Geothermal For Commercial Buildings

HOW

IT

WORKS

Page 12: Geothermal For Commercial Buildings

From a higher temperature to a lower temperature

Heat flows downhill

Page 13: Geothermal For Commercial Buildings

Let’s take 1 pound of water at 80°F and heat it to 90°F by adding 10 BTU

10 BTU

Page 14: Geothermal For Commercial Buildings

Now let’s take 1 pound of water at 90°F and let it cool to 80°F and give up 10 BTU

10 BTU

Page 15: Geothermal For Commercial Buildings

What if we could cool 1 pound of water from 50°F to 40°F?

Heat

Page 16: Geothermal For Commercial Buildings

We would get 10 BTU.

10 BTU

Page 17: Geothermal For Commercial Buildings

What happens when we put heat into water at 212°F ?

Heat

Page 18: Geothermal For Commercial Buildings

Everyone knows Water boils at 212°F.

Page 19: Geothermal For Commercial Buildings

It takes 970 BTU to change 1 pound of water at 212°F to 1 pound of steam at 212°F.

970 BTU

Page 20: Geothermal For Commercial Buildings

In Denver, Colorado, water boils at 202°F.

Page 21: Geothermal For Commercial Buildings

In the olden days, before microwave ovens,

folks used a Pressure Cooker to cook foods faster.

Water boils at 240 °F at 10 PSIG

250 °F at 15 PSIG

Page 22: Geothermal For Commercial Buildings

In the classic high school physics experiment water can be made to boil at any temperature by reducing the pressure.

This concept is the basis of modern air conditioning.

Except air conditioners don’t use water they use Halogenated Chloro Fluoro Carbons like Chlorodifluoromethane and Zeotropic blends of Fluorinated Halocarbons like difluoromethane and pentafluoroethane.

Page 23: Geothermal For Commercial Buildings
Page 24: Geothermal For Commercial Buildings

40.00 83.255

40.00 83.255 21.662 108.31321.662 108.313

Page 25: Geothermal For Commercial Buildings

120.00 274.65

120.00 274.65

40.00 83.255

40.00 83.255

21.662 108.31321.662 108.313

45.952 112.914

45.952 112.914

Page 26: Geothermal For Commercial Buildings
Page 27: Geothermal For Commercial Buildings
Page 28: Geothermal For Commercial Buildings
Page 29: Geothermal For Commercial Buildings
Page 30: Geothermal For Commercial Buildings
Page 31: Geothermal For Commercial Buildings
Page 32: Geothermal For Commercial Buildings
Page 33: Geothermal For Commercial Buildings
Page 34: Geothermal For Commercial Buildings
Page 35: Geothermal For Commercial Buildings
Page 36: Geothermal For Commercial Buildings
Page 37: Geothermal For Commercial Buildings
Page 38: Geothermal For Commercial Buildings
Page 39: Geothermal For Commercial Buildings
Page 40: Geothermal For Commercial Buildings
Page 41: Geothermal For Commercial Buildings
Page 42: Geothermal For Commercial Buildings
Page 43: Geothermal For Commercial Buildings
Page 44: Geothermal For Commercial Buildings
Page 45: Geothermal For Commercial Buildings
Page 46: Geothermal For Commercial Buildings
Page 47: Geothermal For Commercial Buildings
Page 48: Geothermal For Commercial Buildings
Page 49: Geothermal For Commercial Buildings
Page 50: Geothermal For Commercial Buildings
Page 51: Geothermal For Commercial Buildings
Page 52: Geothermal For Commercial Buildings
Page 53: Geothermal For Commercial Buildings
Page 54: Geothermal For Commercial Buildings

What are the

benefits?

Page 55: Geothermal For Commercial Buildings
Page 56: Geothermal For Commercial Buildings

Geothermalvs.

Conventional

Page 57: Geothermal For Commercial Buildings

Uuu

D

E

S

I

G

N

Page 58: Geothermal For Commercial Buildings

D

E

S

I

G

N

Page 59: Geothermal For Commercial Buildings

D

E

S

I

G

N

Page 60: Geothermal For Commercial Buildings

D

E

S

I

G

N

Page 61: Geothermal For Commercial Buildings

Boilers

Page 62: Geothermal For Commercial Buildings

Smoke Stack

Page 63: Geothermal For Commercial Buildings

Water Chillers

Page 64: Geothermal For Commercial Buildings

Earth Shaker 2000

Page 65: Geothermal For Commercial Buildings

Cooling Towers

Page 66: Geothermal For Commercial Buildings

Legionnella

Page 67: Geothermal For Commercial Buildings

Project Example: Zero Arrow Street

Zero Arrow Street, Cambridge, Massachusetts

Page 68: Geothermal For Commercial Buildings

ZERO

ARROW

S

T

R

E

E

T

40,000 Square Feet

Mixed Use: Office/Black Box Theater (American Repertory Theater)

Urban Setting

Heated and Cooled with Three 1,500 Foot Standing Column Wells

LEED Certified

Page 69: Geothermal For Commercial Buildings

ZERO

ARROW

S

T

R

E

E

T

FIRST COSTS OF EACH SYSTEM TYPE

Ground Source Heat Pump (GSHP):

Wells = 3 x $55,000 = $165,000

Water Source Heat Pump (WSGP):

Cooling Tower = $30,000

Boiler = $12,000

Cost Difference:$165,000 – ($30,000+$12,000) = $123,000

Other components are approximately equal for both systems (i.e. heat pumps, ductwork, piping)

Page 70: Geothermal For Commercial Buildings

Annual Energy Costs

Budget Building Design

$12,653.39$16,982.00$4,510.36$326.81$19,697.56$9,955.92Annual Costs

$1.90$1.90$1.90$1.90$1.90$1.90Cost $/Therm

$0.180$0.180$0.180$0.180$0.180$0.180Cost $/KWhr

87130Therms

70,29894,34425,0581,81622,19355,311kWh

Domestic Water

Interior Lighting

PumpsInteriorVentilation

HeatingCooling

TOTAL $64,978.23

Page 71: Geothermal For Commercial Buildings

Annual Energy Costs

Proposed Design

$12,653.39$16,982.00$4,290.12$106.95$10,547.91$9,017.39Annual Costs

$1.90$1.90$1.90$1.90$1.90$1.90Cost $/Therm

$0.180$0.180$0.180$0.180$0.180$0.180Cost $/KWhr

000Therms

70,29894,34423,83459431,47650,097kWh

Domestic Water

Interior Lighting

PumpsInteriorVentilation

HeatingCooling

TOTAL $48,715.67

Page 72: Geothermal For Commercial Buildings

1ZERO

ARROW

S

T

R

E

E

T

Energy Savings

WSHP Cooling $9,956WSHP Heating $19,698WSHP Total $29,654

GSHP Cooling $9,017GSHP Heating $10,548GSHP Total $19,565

Geothermal Heat Pump Savings:$29,654 - $19,565 = $10,089

Page 73: Geothermal For Commercial Buildings

ZERO

ARROW

S

T

R

E

E

T

Simple Payback

System Cost Differential $123,000

Geothermal Heat Pump Savings $10,088

Payback = $123,000 ÷ $10,000/yr. = 12.2 years

Page 74: Geothermal For Commercial Buildings

M

A

I

N

T

E

N

A

N

C

E

Water Source Heat PumpCooling tower water treatment

Cooling tower fan belts

Outdoor piping (roof) exposed to weather

Cooling tower exposed to weather

VFD’s can be fussy (control of CT fans)

Boiler service (mandatory once/year)

Page 75: Geothermal For Commercial Buildings

M

A

I

N

T

E

N

A

N

C

E

Ground Source Heat PumpBuilding loop water treatment/test and add

chemicals if necessary

Other components (i.e. heat pumps and water pumps) require equal maintenance for both systems

Page 76: Geothermal For Commercial Buildings

Geothermal Benefits

Free heatNo fossil fuel hazardsReduced carbon footprintEnhanced serviceabilityNo outdoor noiseNo visual impact outdoorsPositive cashflow day oneSavings increase overtime10% Tax Credit (30% Residential)

Page 77: Geothermal For Commercial Buildings

GeologyAquifer testing (hydraulic and thermal)Well designConstruction inspectionWater quality considerationsRegulatory permits

Certified Professional Geologists,Hydrogeologists, Chemists

Page 78: Geothermal For Commercial Buildings

Water circulation in 1 well

800 ft. to 1,500 ft. deep

Surface bleed for thermal balance

Gravity injection

Permitting

Standing Column Well

Page 79: Geothermal For Commercial Buildings

Designing to the EnvironmentYOUR ANSWERS ARE UNDERGROUND!

Geology affects thermal capacity of wellWater yield affects thermal capacity of wellWater quality affects:

Corrosion ratesO&MRegulatory considerations

Page 80: Geothermal For Commercial Buildings

Aquifer Characteristics

Water yield

Rock density

Thermal conductivity testing – Btu/ft-hr oF

Page 81: Geothermal For Commercial Buildings

C

O

N

S

I

D

E

R

A

T

I

O

N

S

Brackish water –corrosion and water management

Collapsing bore holeWaste management Boston Groundwater Trust (Back

Bay)

Page 82: Geothermal For Commercial Buildings

Regulatory Permitting: Applicable Rules

Underground Injection (UIC) Control ProgramGroundwater discharge Permit Program (314 CMR 5.00)

MADEP Guidelines for Ground Source Heat Pump Wells, February 2009

Page 83: Geothermal For Commercial Buildings

Regulatory Concerns

Data base of injection wells

Thermal pollution

Cross-contamination of aquifers

Page 84: Geothermal For Commercial Buildings

Registration under the UIC Program

Initial registration

Significant system modifications

Change in ownership

Well closure

Page 85: Geothermal For Commercial Buildings

Water Quality Testing

Required for all open loop wells

“Conditional” to “Full” registration

Exceedance may require water treatment

Copper and Lead on return flow

Page 86: Geothermal For Commercial Buildings

CURRENT

REQUIREMENTS

Other permitting requirements:

Bleed water to dry well –UIC registration

Bleed water to sewer or storm drain – local permit

Bleed water to surface water –not allowed until Massachusetts

federal EPA permit renewed

Page 87: Geothermal For Commercial Buildings

CURRENT

REQUIREMENTS

Treatment and expanded permitting required if:

Water quality limits exceeded, or

Using treatment chemicals (i.e. disinfectants, scale inhibitors)

Page 88: Geothermal For Commercial Buildings
Page 89: Geothermal For Commercial Buildings
Page 90: Geothermal For Commercial Buildings
Page 91: Geothermal For Commercial Buildings
Page 92: Geothermal For Commercial Buildings
Page 93: Geothermal For Commercial Buildings
Page 94: Geothermal For Commercial Buildings
Page 95: Geothermal For Commercial Buildings
Page 96: Geothermal For Commercial Buildings

Questions?Thank you for your time.

This concludes the American Institute of Architects Continuing Education Systems Program.

Allied Consulting Engineering Services215 Boston Post Road Sudbury, Massachusetts43 Jefferson Boulevard Warwick, Rhode Island

978-443-7888 alliedconsulting.net

consulting engineering services, inc.

Environmental, LLC