Panel Box sizeper schedule
INTERIOR
Stucco wall assembly:Wall system and
membrane details asspecified by architect
Build-up as required toclear projecting objects
Safe Rail
Flashing
Safe bottomprofile
EXTERIOR2"
min
.
Outline of stuccobeyond
Outline ofdrywall beyond
Architect approvedsealant
Minimum 1 1/2"penetration into
wood framingrecommended
Flashing as specifiedby architect
2 6
2 2
8 8
Stainless steel or equivalent weatherprooffasteners - architect to specify
Architect approvedsealant
16
Mini Safecurtain profile
GENERIC DETAILS©
ROLLSHUTTER RETROFIT SYSTEM
STUCCO WALL APPLICATION
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER.
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
RS_Stucco01
-
INTERIOR EXTERIOR
Safe Rail
Sill Flashing
Safe U-Sill with 1/4"Ødrains @ 18" o.c.
Stucco wall assembly:Wall system and
membrane details asspecified by architect
Outline of stuccobeyondOutline of
drywall beyond
Build-up as required toclear projecting objects
Minimum 1 1/2"penetration into
wood framingrecommended
Architectapproved sealant
2 6
2 6
Architect approvedrod & sealant
Safe bottomprofile
Mini Safecurtain profile
© GENERIC DETAILS
ROLLSHUTTER RETROFIT SYSTEM
STUCCO WALL APPLICATION
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco02
-
Stucco wall assembly:Wall system andmembrane details asspecified by architect
Architectapprovedsealant
Build-up as required toclear projecting objects
Outline of drywallbeyond
INTERIOR
EXTERIOR
Safe Rail
Safe U-Sill
Minimum 1 1/2"penetration into
wood framingrecommended
curtain
Outermost projectionof sill flashing below
2 2
6 6
Architect approvedrod & sealant
© GENERIC DETAILS
ROLLSHUTTER RETROFIT SYSTEM
STUCCO WALL APPLICATION
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco03
-
Stucco wall assembly:Wall system and
membrane details asspecified by architect
Architect approvedsealant
Build-up asrequired to clearprojecting objects
Outermostprojection of sill
flashing below
Outline of drywallbeyond
INTERIOR
EXTERIOR
(2) Safe Rails
Safe U-Sill
Minimum 1 1/2"penetration into
wood framingrecommended
curtaincurtain
Outline of drywallbeyond
Architect approvedsealant
Architect approvedrod & sealant
© GENERIC DETAILS
ROLLSHUTTER RETROFIT SYSTEM
STUCCO WALL APPLICATION
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco04
-
Minimum 1 1/2"penetration into
wood framingrecommended
Outline ofdrywall beyond
Mini SafeProfile
Outline of stuccobeyond
EXTERIORINTERIOR
Stucco Wall assembly:Wall system and
membrane details asspecified by architect
Removable access panel under Panel Boxopening by others (matched to existing soffit)
Soffit
Soffit Joist
*Do not attach removableaccess panel to Panel Box
Roof System:Details as specified by architector structural engineer
1" x 1" x 1/4" aluminum angle forservice panel attachment
Ceiling Joist
Architect approved sealant
Flashing
Safe Rail
2 6
2 6
2
10
2
10
2
4
Panel Box sizeper schedule
Wood blockingas required
© GENERIC DETAILS STUCCO WALL APPLICATION
PANEL BOX IN-SOFFIT SYSTEM
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco05
-
Stucco Wall assembly:Wall system and membrane
details asspecified by architect
Ceiling Joist
Roof System:Details as specified by architector structural engineer
Soffit Joist
Architect approved sealant
Outline of stucco beyond
Safe bottom profile
Flashing
Safe RailEXTERIOR
Soffit
Panel Box sizeper schedule
INTERIOR
Outline ofdrywall beyond
Minimum 1 1/2" penetrationinto wood framing
recommended
2 6
2 6
Wood blockingas required
Mini Safe curtain profile
© GENERIC DETAILS
PANEL BOX BELOW-SOFFIT SYSTEM
STUCCO WALL APPLICATION
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco06
-
2"
min
.
Outline ofdrywall beyond
Minimum 1 1/2"penetration into
wood framingrecommended
Stucco wall assembly:Wall system and
membrane details asspecified by architect
Architect approvedsealant
Outline of stuccobeyond
EXTERIOR
Flashing
Safe Rail
INTERIOR
Panel Box sizeper schedule
Build-up as required toclear projecting objects
16
Stainless steel or equivalent weatherprooffasteners - architect to specify
Architect approvedsealant
Flashing asspecifiedby architect
Safe bottomprofile
Mini Safecurtain profile
© GENERIC DETAILS STUCCO WALL APPLICATION
PANEL BOX BELOW-SOFFIT SYSTEM
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco07
-
INTERIOR EXTERIOR
Safe Rail
Sill Flashing
Stucco wall assembly:Wall system and
membrane details asspecified by architect
Outline of stuccobeyondOutline of
drywall beyond
Build-up as required toclear projecting objects
Minimum 1 1/2"penetration into
wood framingrecommended
Architectapproved sealant
Safe U-Sill with 1/4"Ødrains @ 18" o.c.
Safe bottomprofile
Mini Safecurtain profile
© GENERIC DETAILS STUCCO WALL APPLICATION
PANEL BOX BELOW-SOFFIT SYSTEM
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco08
-
Stucco wall assembly:Wall system andmembrane details asspecified by architect
Architectapproved sealant
Build-up as required toclear projecting objects
Outline of drywallbeyond
INTERIOR
EXTERIOR
Safe Rail
Safe U-Sill
Minimum 1 1/2"penetration into
wood framingrecommended
curtain
Outermost projectionof sill flashing
© GENERIC DETAILS
PANEL BOX BELOW-SOFFIT SYSTEM
STUCCO WALL APPLICATION
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco09
-
Stucco wall assembly:Wall system andmembrane details asspecified by architect
Build-up asrequired to clearprojecting objects
Outermostprojection of sill
flashing
Outline of drywallbeyond
INTERIOR
EXTERIOR
Safe Centre Rail
Safe U-Sill
Minimum 1 1/2"penetration into
wood framingrecommended
Outline of drywallbeyond
Architect approvedsealant
Architectapproved sealant
© GENERIC DETAILS
PANEL BOX BELOW-SOFFIT SYSTEM
STUCCO WALL APPLICATION
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco10
-
Panel Box sizeper schedule
INTERIOR
Stucco wall assembly:Wall system and
membrane details asspecified by architect
Pro-40 Rail
Flashing
Safe bottomprofile
EXTERIOR
Outline of stuccobeyond
1x treated shutterhousing (providesaccess for installationprior to application ofexterior finish)
Header beam (consultarchitect or structuralengineer)
Custom shop fabricatedremovable millwork
panel for service access
Removable 1" thickrigid foam insulation
Vapour barrier adheredto studs or blocking
Custom fabricated,watertight, continuous drip
pan flashing
Wall thickness will vary with rollshutter housing size.Talius housing sizes must be coordinated with actual lumber sizes toavoid conflicts - to be specified by architect or structural engineer
Architectapproved sealant
Do not installpanel box lid
Mini Safecurtain profile
© GENERIC DETAILS
PANEL BOX IN-WALL SYSTEM
STUCCO WALL APPLICATION
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco11
-
INTERIOR EXTERIOR
Pro-40 Rail
Continuous sill panflashing - as specifiedby architect
Safe bottomprofile
Safe U-Sill
Stucco wall assembly:Wall system and
membrane details asspecified by architect
Outline of stuccobeyond
Outline ofwindow frame
beyond
Architectapproved sealant
Window set back into wallfar enough for all projecting
trim to have clearance ofshutter slats and side rails
Custom stone windowsill - as specified inarchitectural projectdocuments
Outline indicatesheight of sill panflashing at jambbeyond
Continuous sill panflashing - as specified
by architect
U-sill to be securedwith #8 self tapingmasonry screws@ 6" o.c.
Mini Safe curtain profile
© GENERIC DETAILS STUCCO WALL APPLICATION
PANEL BOX IN-WALL SYSTEM
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco12
-
INTERIOR
24
curtain
Safe U-Sill
EXTERIOR
Stucco wall assembly:Wall system andmembrane details asspecified by architect
Outermost projection of customstone window sill - Sill asspecified in architecturalproject documents
Outline of millwork serviceaccess panel above
Outline indicatesextent of sill panflashing within wallcavity
Treated 1x at side rail (toprovides access for installationprior to application of exteriorfinish)
Outline indicatesextent of sill pan
flashing withinwall cavity
Architect approved sealant
Pro-40 Rail
© GENERIC DETAILS STUCCO WALL APPLICATION
PANEL BOX IN-WALL SYSTEM
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco13
-
2X8
Structural header orlaminated joist(consult architect orstructural engineer)
Panel boxopening
Double 2 x 8 top plate
Window opening
2 x 8 cripples @ 16" o.c.
Dashed line indicateswindow unit
Double 2 x 8 sill plate
2 x 8 trimmer
2 x 8 king stud
Use 2 x 4's to frame outrough opening to provide
an attachment surface forcomponents and allows
set-back of window2X8 trimmerripped down tosupport panelsill plate above
Panel box sill plate (2 x 8ripped down to fit side railsand slats into outside face.)
2 x 8 studs @ 16" o.c.
2 x 8 cripples @ 16" o.c.
2 x 8 sole plate
Trimmer to support panelbox sill plate (2 x 8 ripped
down to fit side rails andslats into outside face.)
© GENERIC DETAILS STUCCO WALL APPLICATION
PANEL BOX IN-WALL SYSTEM
NOTE: IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUPPLY ALL REQUIRED SEALANTS, FLASHINGS, AND MOUNTING HARDWARE.
DISCLAIMER: DETAILS PROVIDED BY TALIUS ARE GENERAL RECOMMENDATIONS. CONSULTATION WTIH AND EXPERIENCED ARCHITECT, STRUCTURAL ENGINEER, OR CONTRACTOR ISNECESSARY FOR PROPER EXECUTION OF WEATHERPROOFING DETAILS, STRUCTURAL REQUIREMENTS AND COMPLIANCE WITH REGIONAL AND LOCAL BUILDING CODES. TALIUS PLACES SOLERESPONSIBILITY OF THESE INSTALLATION ISSUES WITH THE ARCHITECT, STRUCTURAL ENGINEER, GENERAL CONTRACTOR AND/OR BUILDING OWNER. RS_Stucco14
StuccoWall_Rollshutter_Dec14-09p.1p.2p.3p.4p.5p.6p.7p.8p.9p.10p.11p.12p.13p.14