GEM Integrated PCB readout and cooling
description
Transcript of GEM Integrated PCB readout and cooling
CMS GEM Upgrade Workshop III1
GEM Integrated PCB readout and cooling
Andrey MarinovOn behalf of GEMs for CMS collaboration
18/04/2012
CMS GEM Upgrade Workshop III2
Talk Outline GE1/1 Proto1 GE1/1 Proto2 GE CMS detector – Cooling and integrated
readout PCB NS2 Technique Detector Powering plan Cooling Calculations Readout strips - PCB design On going activities
18/04/2012
CMS GEM Upgrade Workshop III3
GE1/1 Detector Layout
GE1/1 Proto1
GE1/1 Proto2
Drift, GEM1 = 3mm
Drift, GEM1 = 3mm
GEM1, GEM2 = 2mm
GEM1, GEM2 = 1mm
GEM2, GEM3 = 2mm
GEM2, GEM3 = 2mm
GEM3, Readout = 2mm
GEM3, Readout = 1mm
18/04/2012
4
GE1/1 Prototypes – Proto1Readout PCB with strips
18/04/2012CMS GEM Upgrade Workshop III
0.8mm pitch1.6mm pitch256 strips for each eta partition
128 channels per VFAT connector
PCB thickness = 3mm1024 channels
CMS GEM Upgrade Workshop III5
GE1/1 Proto2 – Readout Board
18/04/2012
Strip’s pitch 0.8mm Strip’s pitch 0.4mm24VFAT FEBs3072 channels
CMS GEM Upgrade Workshop III6
From Thermo Stretching to NS2 Technology
18/04/2012
CMS GEM Upgrade Workshop III7
GE CMS Prototype Full size detector ready for installation in CMS 3840 Readout channels. Based on NS2 Technology. Gaps between the detector electrodes
3/1/2/1mm All services integrated and compatible with
the CMS infrastructure. Thanks to NS2 method the detector can be
open and elements can be changed.
18/04/2012
CMS GEM Upgrade Workshop III8
GE CMS Prototype - Power Consumption VFAT FEB power =18W HV Divider = 4W dc/dc converters - 80% efficiency GBT = 2.25W
Total Power for the detector is 34W
18/04/2012
CMS GEM Upgrade Workshop III9
GE Detector Cooling Sketch
18/04/2012
CMS GEM Upgrade Workshop III10
Clearance Available Inside the GE detector
9mm clearance
18/04/2012
CMS GEM Upgrade Workshop III11
VFAT Cooling Sketch
18/04/2012
CMS GEM Upgrade Workshop III12
VFAT3 PCB Design
50mm
44mm
18/04/2012
Multilayer chip bonding
CMS GEM Upgrade Workshop III13
VFAT Cooling Sketch
18/04/2012
Water flow rate = 0.02826 kg/s
CMS GEM Upgrade Workshop III14
VFAT Chip Cooling
18/04/2012
Calculations made by Enrich Da Riva – CERN CFD team
CMS GEM Upgrade Workshop III15
Cooling Calculations for the HV Divider
Calculations made by Enrico Da Riva – CERN CFD team 18/04/2012
CMS GEM Upgrade Workshop III16
GE Detector – Cooling of the HV divider
18/04/2012
CMS GEM Upgrade Workshop III17
VFAT3 Cooling
18/04/2012
Calculations made by Enrico Da Riva – CERN CFD team
CMS GEM Upgrade Workshop III18
GE Integrated Readout Board For the moment the full size readout board is
foreseen to be 7 layers providing : Strips and connection to the FEB Power to the FEBs Ground connection LVDS signal lines from FEB to the optical
transceiver GBT
18/04/2012
CMS GEM Upgrade Workshop III19
On going activities VFAT PCB design – nearly finished GE readout board on going
18/04/2012
CMS GEM Upgrade Workshop III20
Thank you.