Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212...

84
Geberit HDPE Application Technique

Transcript of Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212...

Page 1: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Geberit HDPEApplication Technique

Page 2: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

100 212

90 194

80 176

70 158

60 140

50 122

40 104

35 95

30 86

25 77

20 68

15 59

10 50

5 41

0 32

–5 23

–10 14

–15 5

–17,8 0

–20 –4

–25 –13

–30 –22

Converting tables

Converting table Inch–Millimeter

Inch 3⁄8" 1⁄2" 3⁄4" 1" 11⁄4" 11⁄2" 2" 21⁄2" 3" 31⁄2" 4" 5" 6" 8" 10"

mm 9,5 12,7 19 25,4 31,8 38,1 50,8 63,5 76,2 88,9 101,6 127 152,4 203,2 254

Geberit Ø outside - - - 32 40 50 56 63 75 90 110 125 160 200 250

Geberit Ø inside - - - 26 34 44 50 57 69 83 101,4 115,2 147,6 187,6 234,4

Temperature scales Pressure scale

1 bar = 1000 mbar

1 bar = 100 000 Pa (= )

1 bar = 10,2 m Water column

1 bar = 14,5 psi

1 psi = 6896.43

1 psi = 1 lb/square inch

Length scale

1 m = 1000 mm

1 m = 100 cm

1 m = 10 dm

1 cm = 10 mm

1 dm = 10 cm = 100 mm

°°CC °°FF

To convert Centigrade to Fahrenheit:Multiply Centigrade by 1,8 and add 32.

°F = (°C x 1,8) + 32

To convert Fahrenheit to Centigrade:Subtract 32 from Fahrenheit and divideby 1,8.

°C = (°F –32) : 1,8

Nm2

Nm2

Page 3: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Geberit HDPE page

3 4

Thermal movement 19 - 20

Accomodating thermal movement

gel noitcelfeDtekcos noisnapxE

stekcarb ediug dna stekcarb rohcnAselpmaxe noitallatsnI

Prevention of thermal movement

noitallatsni digiR Embedded fixed points, encased in concrete

Mounting instructions

gnidlew ttuBgnidlew ortcelE

noitacirbaferP loot riapeR

stekcos noisnapxE

Special application fields

eganiard dnuorgrednU sllaw gnidliub hguorht noitartenep epiP

elohnam ot noitcennoC

noitallatsni erusserp woLerusserp lanretni dna lanretxE

noitcetorp eriF

Geberit HDPE characteristics

scitsiretcarahc lacisyhP seitreporp lacigolocE

Comments on individual properties )ecneciL tirebeG( gnirepmeT

eulaV Hptsil ecnatsiser lacimehC

Norms/Certificates

Overview

Drainage systemApplication field for pipes and fittings

HDPE pipes, fittings and toolsJointing methods

Water proofing

5 - 78 - 17

18

2122

23 - 2526 - 29

3132 - 33

34 - 36

37 - 3940 - 42

43 44

Ball Junctions

45 - 495051

52 - 53

545556

5758 - 5960 - 6364 - 65

6667 - 76

77 - 78

30

Page 4: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

2

Page 5: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

3

Drainage system

1 Ground pipe

2 Main stack

3 Branch pipe

4 Connector pipe

5 Ventilation stack

6 Rainwater down pipe

7 Domestic drainage

8 Public sewer

2

4

5

66

7

8

3

1

Page 6: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

44

Description Symbol House Underground Bridge Pressure Pluviadrainage drainage drainage load

Pipe X X X X X

Bend 45° X X X X X

Bend 881⁄2° X — — — X

Bend 90° X X X X X

Branch 45° X X X — X

Branch 881⁄2° X — — X X

Ball fittings X — X — —

Reducer X X X X X

Apparatus connections X — — — —

Butt welded joints X X X X X

Electroweld sleeve coupling/flange X X X X X

Expansion socket X X X —

Ring seal socket X — — — —

Flange bushing X X X X X

Double flange bushing X X X X X

Access pipe X X X X X

X = Applicable— = Not applicable = For horizontal installation max. ∅ 110

Application field for Geberit HDPE pipes and fittings

Page 7: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

5

Geberit HDPE pipes

5 m

HDPE pipes

Nominal (Outside) Wall Inside Area Weight Weight Pressure* Seriesdia. thickness dia. empty full nominal (ISO)d (mm) s (mm) di (mm) A (cm2) kg/m kg/m PN S Art. No.

40 3 34 9,0 0,331 1,239 6 6,3 360.000.16.0

50 3 44 15,2 0,420 1,940 6 8,3 361.000.16.0

56 3 50 19,6 0,471 2.434 6 — 363.000.16.0

63 3 57 25,4 0,536 3,087 4 10 364.000.16.0

75 3 69 37,3 0,644 4,383 4 12,5 365.000.16.0

90 3,5 83 54,1 0,903 6,313 4 12,5 366.000.16.0

110 4,3 101,4 80,7 1,350 9,424 4 12,5 367.000.16.0

125 4,9 115,2 104,5 1,750 12,171 4 12,5 368.000.16.0

160 6,2 147,6 171,1 2,840 19,947 4 12.5 369.000.16.0

200 6,2 187,6 276,4 3,580 31,216 3,2 16 370.000.16.0

250 7,8 234,4 431,5 5,630 48,774 3,2 16 371.000.16.0

315 9,8 295,4 685,3 8,920 77,442 3,2 16 372.000.16.0

Standard length of Geberit HDPE pipes = 5 meters (5000 mm)* = Nominal pressure refers to pipe only not to fittings

ISO = International Standard Organisation

Standards – International ISO 8770 / 8772

– European CEN / TC 155 / CEN EN 12056

– Switzerland SN 592 000

– Germany DIN 8075 / 19535 / 19537

– Austria B 5177

– France NF T 54 072

– Italy UNI 8451

– Belgium NBN 42-112

– Netherlands NEN 7008

– Denmark NKB Nr. 8

– Great Britain BS /6367/5572/6437/5114

– Australia AS/NZS 4401/AS/NZS 5065

– Singapore PSB/ENV

cm 2A

d

sdi

Page 8: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Prefabricated or conventional installation Pipeline embedded in concrete Underground drainage pipes

HDPE fittings dia. 40mm - 315mm

Silent fittings dia. 56mm - 160mm (refer to separate Application Technical Manual)

Geberit HDPE fittings

6

Page 9: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

7

Geberit tools

Pipe Cutter Hand Mitre Saw

"BA

RY

""B

AR

Y"

Kun

stst

off-

Sch

wei

ssap

par

ate

Kun

stst

off-

Sch

wei

ssap

par

ate

Typ

e: A

-Ty

pe:

A-

Vol

t 23

0V

olt

230

Wat

tW

att

Nr.

Nr.

W.R

iese

n B

asel

(Sch

wei

z)

W.R

iese

n B

asel

(Sch

wei

z)

Ditt

inge

rstr

asse

45

Ditt

inge

rstr

asse

45

Welding Plate Repair Tool

B.3

56.2

20/0

01

Electrofusion Machine Start Switch

506375110

90125

160

TYP

MEDIA 84

MASCH. NR.

Welding Machine MEDIA Welding Machine UNIVERSAL

Page 10: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

8

Geberit HDPE jointing methods Overview

The many Geberit jointing methods offer solutions for all situations.

Butt weld Electroweld sleeve coupling

Ring-seal socket Screw-threaded joint

Linear expansion socket

Flange joint Contraction sleeve Coupling for PE-Silentand adaptor only

These connections have different properties, and are therefore classified according to the way inwhich they are assembled as follows:

a) To be openedJointing methods which can be disconnected after assembly.

b) Not to be openedJointing methods which cannot be disconnected after assembly.

c) Tension-resistantConnections which withstand tensional forces.

d) Non-tension-resistantConnections which cannot withstand tensional forces.

Buttweld

Jointingmethods

Situation

Tension resistantNot to be opened

Tension resistantTo be opened

Non-tension resistantNot to be opened

Non-tension resistantTo be opened

Ring-sealsocket

Screw-threaded joint with-out flange bushing

Screw-threadedjoint withflange bushing

Expan-sion soc-ket

Contrac-tionsleeve

CouplingFlange joint

Application

X X

X X X

XX

XX

Electro-weldsleevecoupling

Page 11: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

9

All diameters from Ø 40 to 315 mm can be welded.Connection properties

b) not to be openedc) tension-resistant

Use

Welding is the easiest jointing method, providing the many advantageous bene-fits of prefabrication; HDPE needs no other component in order to be welded.

It can be used in all circumstances where prefabrication is used on site or in theworkshop.

The essential conditions for a perfect weld are:

• Cleanliness of the welding plate and the parts which are to be welded.

• A correct welding plate temperature.

• The correct pressure for jointing the parts.

• The parts to be welded must be cut square <) 90°.

Butt welding takes up little space. The edge of the weld does not obstruct thepipe, leaving its internal cross-section virtually unchanged. Even quite complica-ted distribution parts can be assembled in a small space, without wastage ofmaterial, because lengths of pipe or elbow sections can be easily reusedthrough butt welding.

The allowance for butt welds is approx. as big as the wall thickness of the pipe.

pipe diameter (mm) 40–75 90 110 125 160 200 250 315

butt weld s (mm) 3 4 5 5 7 7 8 10

506375 11090

125160

TYPMEDIA 84

MASCH. NR.

Butt welding

A simple and reliable connection

Machine welding Media ø 40 – 160 mm Universal ø 40 – 315 mm

Manual welding up to Ø 75 mm

Indicative values of operating pressure

Wel

ding

tim

e in

min

.

Welding time

Warming-up time

5

4

3

2

1

0mm 2 4 6 8 10 12

ø kg40 650 756 863 975 1090 15

110 22125 28160 45200 57250 90315 140

Warming-up and welding times Guidevalues for

weldingpressure

A

B

Allowance for butt welds

ø 56 110 250

Pipe wallthickness

Page 12: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Electroweld sleeve coupling

A short, simple and reliableconnection

Available from Ø 40 to 315 mm.

Connection properties

b) not to be openedc) tension-resistant

Use

On-site welding, conversion, additional installations, repairs. The small outsidediameter provides a great advantage.

Conventional assembly, on the nesting principle, made for easy use. The jointobtained is simple, quick and reliable.

The heating and melting zone is divided into two fields, as there are no electricalresistances in the centre of the sleeve. This provides a very satisfactory safetyfactor.

Also the ends of the pipes are not heated, the zones remain effectively cold,and provide further reinforcement, thus cancelling out shrinkage of the pipe.

The pressure required for welding is obtained from the shrinking effect of thesleeve when it is heated, and is evenly distributed over the entire weld. Thisshrinkage has a compensating effect on pipe diameter measurement toleran-ces.

The electrical resistance wires will not corrode. Once the weld has been madethey are entirely covered by PE.

The use of original Geberit equipement, especially tempered Geberit HDPEpipes, are recommended for correct welding.

Electrical sleeves can be made to slide by removing the central stop ring, thusmaking system conversion and repair work easier.

The stop ring can easily be removed with a screwdriver.

60

150

Ø 40 – 160

Ø 200 – 315

Electroweld sleeve coupling ø 40-160 mm

10

Page 13: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Assembly instructions are the same for both ring-seal sockets and screw-threadedjoints, the sleeve lengths are the same for corresponding diameters. The effective sleeve length, i. e. the measurement – X – from the O-ring to the base of the socketgoverns the maximum length of pipe which can be connected by individual joints.

For HDPE approximately 15 mm of spigot should be allowed for every 1 m of pipe.

The pipe must be fully inserted into the socket, because the socket does not act as an expander. Owing to the pipe thickness and the low thermal conductivity of HDPE, thesocket seal has very satisfactory resistance to heat and no shrinkage of the O-ringoccurs. The O-ring has a round seat regardless of pipe movements. The O-ring remains fixed inthe seat and is always in contact with the pipe.

Protection cap

Length «X» varies with the diameter Ideal fitting is obtained by chamfering the pipeend to approximately 15°, lubricating it withsoft soap, Silicone or Vaseline. Do not usemineral oil or grease which can damage therubber seal.

x

Ring-seal socket joint

Available from Ø 40 to 160 mm.

Connection properties

a) to be openedd) non-tension-resistant

Use

Ring-seal socket joints can be used to provide a connection between various prefabri-cated parts for simpler assembly.

Assembly

May be used either vertically or horizontally. The small overall dimensions provide an advantage where space is limited. Can easily be assembled or released even whereaccess is difficult.

Ring-seal sockets are provided with a yellow protection cap to prevent the ingress ofdebris during installation.

11

Page 14: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

12

Screw-threaded joint

Available from Ø 40 to 110 mm.

Connection properties

a) to be openedd) non-tension-resistant

Use

Screw-threaded joints are used for assembly of various prefabricated partswhen it is necessary to easily dismantle and also as the connection to sinktraps and shower trays.

1

2

3

4

Complete screw-threaded joint

1. Nut2. Washer3. Seal4. Thread

The seal is pressed against the thread.

A minimum surface area of the seal is in contact with water.

The seal is pressed against the flange bushingand the thread.

Available from Ø 40 to 110 mm.

Connection properties

a) to be openedc) tension-resistant

Use

Wherever there is the possibility that a pipe can be pulled out of a screw-threa-ded joint by axial tensile forces a flange bushing must be used to ensure thatthe connection will resist these forces. It is also recommended that a screw-threaded joint with flange bushing should be used when installing in floors orslabs, where the length of pipe between two connections (elbows, branches orsleeves) is longer than 2 metres.

1

2

3

4

1. Nut2. Flange bushing3. Seal4. Thread

Screw-threaded jointwith flange bushing

Screw-threaded jointwithout flange bushing

1

2

3

4

1

2

3

4

Page 15: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

13

Expansion socket

Available from Ø 40 to 315 mm.

Connection properties

b) not to be openedd) non-tension-resistant

Use

An expansion socket is recommended between anchor brackets, particularly oninstallations assembled with rigid joints and where excessive thermal movementis anticipated. At least one expansion joint must be provided on vertical stacks running fromfloor to floor, long collector pipelines and before connecting to the buried drainpipework.

Different conditions apply for underground installations. For this application fieldsee page 49.

Installation

Can be used either vertically or horizontally. One advantage is the depth of thesleeve which makes the assembly of downpipes and mains easier, allowingboth vertical and horizontal corrections (e.g. in level, and in the precise positio-ning of the direction of branches and elbows).

A firm anchor bracket must always be located behind the expansion socket toavoid any movement of the socket in the event of expansion or contraction.

The special shape of the seal allows the pipe to slide within the socket duringexpansion and contraction, ensuring that the connection remains perfectlywatertight even under heavy hydraulic load.

Horizontal assembly (e.g. at 20°C)

Example: Insertion depth in an ambient temperature of 20°C(Vertical assembly).

The following conditions are important to ensure perfect and easy assembly ofthe sleeve:

1. Chamfering the inserted pipe end to approximate <) 15°.

2. Check the scale on the outer surface of the expansion socket for insertion depth.

3. Mark the correct insertion depth on the pipe.

4. Lubricate the pipe end well with soft soap, Silicone or Vaseline.N.B. Do not use oil or grease which can damage the rubber seal.

For more information see pages 22, 28, 44 and 49.

A special expansion socket with stainless steel protection for the rubber sealcan be used for heavy duty industrial and laboratory applications.

Page 16: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

14

Flanged joint

Loose flange

Nut and bolt

Seal

Flange adaptor

Blind flange

Bolts

Loose flange,PE coated

Flange adaptor

Seal

Flange adaptor

Loose flange

Nuts

Available from ∅ 50 to 315 mm.

Connection properties

a) to be openedc) tension-resistant

Use

Flanges are normally used as disconnectable joints for low pressure installations(industrial plant, pump connection, tanks and swimming pools).

The flange connection system offers easy connection to existing iron and steelinstallations.

As inspection access opening made by using a blind flange.

Flanges are sintered, i.e. they are coated with polyethylene, and have standarddimensions (PN 3.2 – PN 10).

Page 17: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

15

Geberit HDPE contraction sleeve

d di (mm) H (cm) h (cm) h1 (cm) K (cm) for Ø (mm) Art. No.50/ 60 30 24 6 17 53– 54 152.651.16.1

73 27,5 22 5,5 17 60– 67 152.197.16.180 28,5 23 5,5 17 67– 74 152.198.16.190 30,5 23,5 7 17 80– 84 152.652.16.1

100 31 24 7 17 90– 94 152.653.16.156/ 60 26,5 20,5 6 14 53– 54 152.654.16.1

73 24,5 19 5,5 14 60– 67 152.149.16.180 24,5 19 5,5 14 67– 74 152.150.16.1

63/ 73 26,5 20,5 6 14 60– 67 152.657.16.180 24,5 19 5,5 14 67– 74 152.658.16.190 26,5 19,5 7 14 80– 84 152.659.16.1

75/ 80 25 19 6 12 67– 74 152.152.16.190 24,5 17,5 7 12 80– 84 152.151.16.1

100 15 8 7 12 90– 94 152.661.16.190/110 17 7 10 – 84– 98 366.550.16.1

110/125 16 6 10 – 102–111 367.551.16.1140 18 8 10 2,5 102–126 367.550.16.1

125/150 18 8 10 1 116–136 368.550.16.1160/195 20 8 12 1 148–180 369.550.16.1

230 30 14 18 5 189–212 369.551.16.1

200–315 available on request (see HDPE catalogue)

d

ABdi

K

Hh

h1

pipe end

ring seal rubber ring

Geberit HDPEcontraction sleeve

Laboratory sink

Available from 50 to 160 mm

Connection propertiesb) rigid, non-removabled) non-tension-resistant

UseThe Geberit HDPE contraction sleeve is a convenient connection possibility formost uneven, irregular or special materials.A common additional application method is also the connection from HDPE to different clay ware apparatus, e. g. for Laboratory sinks.

InstallationThe enclosed rubber ring will be placed over the pipe end. Make sure that the rubber ring will be placed in the middle of the sleeve length (h2). Then push thecontraction sleeve over the pipe end. Apply low heat (approx. 125°C) evenly around the socket, moving the blow lamp constantly.The sleeve will now shrink and give an absolute watertight and strong connection. Afterwards fix the contraction sleeve pipe with an anchor bracket.

Ø

For Ø 125–315 mm use two soft flames.

Contraction sleeve with seal

approx.125°C

Geberit contractionsleeve

Anchor bracket

rubber ring

AB

Page 18: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

16

Geberit HDPE adapter clamp

Important:

If the joint from HDPE to steel –cast iron or earthenware – ismade with a coupling, it has tobe secured by an anchorbracket.

Install the anchor bracket as close as possible to the coupling.(Maximum 15 cm)

1 Anchor bracket

2 Butt weld seam

3 Coupling

4 PE adaptor with reinforcement ring

5 Steel, cast iron, clay, fibre cementpipes

Available from Ø 48 to 326 mm.

Connection properties

a) to be opened

d) non tension resistant

Use

The adapter clamps have multiple functions and can consequently be used asadapters to thirdparty materials as well as any other types of connection.

Installation

It is necessary to insert an appropriate reinforcement ring into the ends of theHDPE-pipe first when these clamps are used as adapters to HDPE-pipes orfor HDPE-pipe connections.

Page 19: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

17

Geberit HDPE adaptors

Pipe threads (for detail information see HDPE catalogue)

Connection to: Thread dia. Geberit dia. Material

Male pipe thread 1/2”–21/2” 40–75 mm HDPE with steel ring reinforcement

Female pipe thread 11/4"–21/2” 50 – 75 mm HDPE with steel ring reinforcement

Female pipe thread 11/2"–2" 50 + 56 mm Adaptor in brass + PE nut

Threaded pip ends (for detail information see HDPE catalogue)

Soldering / Welding (for detail information see HDPE catalogue)

Connection to: Thread dia. Geberit dia. Material

Connection to: Pipe dia. Geberit dia. Material

Male-thread 11/4”–2" 40 + 50 mm HDPE, upon request also available with nut in brass

Male-thread 60 x 1/8” 40 + 50 mm HDPE

Female-thread 1/2”–1" 40 + 50 mm HDPE, with brass nipple

Male pipe thread 2"– 3" 56 + 75 mm Adaptor in brass + PE nut

Lead 50/60 56 mm Brass with PE nut forsoldering

Lead 50/60 56 mm Lead with PE nut for welding or soldering

PVC 50 + 63 56 mm PVC for solvent cement joint + PE nut

Page 20: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

18

Water proofing

Attention: Thermal expansion or contraction of the pipe is to be prevented.Maximum water pressure 0,1 bar.

Installation examples

50 cm

50 cm

PipeSealing

Waterproofingmembrane

Waterproofingmembrane

Electroweld sleeve coupling (to prevent expansion or contraction)

Expansionsocket

Anchor BracketReducer

Access pipe

Sealing

Waterproofingmembrane

Wherever a water proof layer is required, the Geberit sealing for passagesthrough walls or ceilings provides a perfect watertight seal between the HDPEpipe and the water proof membrane.

Type 1: «Resistit» for connection with bitumnType 2: PVC to be welded with PVC sheetType 3: PE to be welded with Sarnafil FPO-A-foilFor Geberit HDPE pipes Ø 50, 56, 75, 110, 125 mm

Page 21: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

19

Thermal movement

Physical principal: All materials expand as temperature increase.If the temperature falls, the material contracts.

α = 0,2 mm/m • K

Rule of thumb: ∆t 50° = 10 mm/m

Geberit HDPE Expansion Coefficient

Length Variation Table

30°C

80°C

0°C

Example:

1. Sought: Thermal expansion ∆L

2. Given:Maximum temperature = 80°CInstallation temperature = 20°CTemperature difference ∆t = 60°C

Pipe length = 4 m

3. Result:Thermal expansion ∆L = 4,8 cm

= 48 mm

Pipe length

Tem

pera

ture

diff

eren

ce ∆

t in

°C

Determination of thermalexpansion of HDPE(average linear expansioncoefficient 0,2 mm/m K)

1000 mm

1010 mm

994 mm

5000 mm

5050 mm

4970 mm

Length alteration (∆L) of the expansion leg in cm

Page 22: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

20

Thermal movement

There are alternativemethods of installing theGeberit HDPE Drainage

System.

Factors that will influencethermal movement

Methods of accomodatingthermal expansion

and contraction

Prevention of thermal expansion and contraction

Deflection Leg ExpansionSocket

Rigid Fastening InstallationEmbedded in

Concrete

Page 23: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

21

2

4

6

8

10

12

14

16

18

20

0 20 40 60 80 100 120 140 160 180 200 220 240 260

4,8

73

Länge des Biegeschenkels BS in cm aus Formel BS = ca. 10 x L x D

Bestimmung desBiegeschenkels aus PE

Aussen-ø

Läng

enän

deru

ng

L d

es D

ehnu

ngss

chen

kels

in c

m

4032 50-63 75 90 110 125 140 160 200 250 315

Deflection leg

Compensating thermal expansion by deflection leg

+80°C +20°C –10°C

4000

AGG

A

DL

+ 60 – 30

G Guide bracketA Anchor bracketDL Deflection leg

Determining the length of the deflection leg by calculation

Length of the deflection leg (DL) in mm according the formula

Outer-Ø

Line

ar e

xpan

sion

or

cont

ract

ion

∆L

in c

m

Determination of the deflection leg of HDPE

10 x √∆L x Ø Example: DL = 10 x √48 x 110 = 730

Determining the length of the deflection leg fromchart

Length of deflection leg DL in cm. Formula DL = ca. 10 x √∆L x Ø

∆L = L x α x ∆t

Page 24: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

22

Expansion socket

The Geberit expansion socket is designed to counteract the variation in length due tothermal expansion and contraction of max. 6 m Geberit HDPE pipes.

Application: HorizontallyVertically

Diameter: Ø 40 – 315 mm

Legend: Expansion socket: compensates the change of lengthBracket: provides an anchor pointElectroweld sleeve: holds anchor bracket in position

Note: Each expansion socket needs to be fixed with 1 anchor bracket.

Page 25: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Anchor bracket for expansion socket

Thrust force «P» when inoperationØ Thrust force P[kg] [N]

50–63 10kg 100N75 12kg 120N90 20kg 200N

110 30kg 300N125 40kg 400N 160 70kg 700N200 100kg 1000N250 150kg 1500N315 220kg 2200N

The table beside shows the correct pipe nipple diameter required depending on distance «L» to effectively withstand thrust force «P».

The main purpose of the anchor bracket is to prevent any movement of the expansion socket.

The distance «L» and the thrust forces «P» have to be taken in account, when selecting the diameter of the pipe nipple between mounting plate andbracket.

The thrust force «P» is the slide resistance between rubber seal and HDPE pipe.This force depends on the pipe diameter.

Diameters of Geberit HDPE pipe

Distance 50/56/63/75/90 110 125 160 200 250 315from ceiling Pipe nipple used

L (mm) Ø Ø Ø Ø Ø Ø Ø

100 1⁄2" 1⁄2" 1⁄2" — — — —

150 1⁄2" 1⁄2" 1⁄2" 1⁄2" — — —

200 1⁄2" 1⁄2" 1⁄2" 1⁄2" 3⁄4" 1"

250 1⁄2" 1⁄2" 1⁄2" 3⁄4" 1" 1" 5⁄4"

300 1⁄2" 1⁄2" 1⁄2" 3⁄4" 1" 5⁄4" 5⁄4"

350 1⁄2" 1⁄2" 1⁄2" 1" 1" 5⁄4" 11⁄2"

400 1⁄2" 1⁄2" 3⁄4" 1" 1" 5⁄4" 11⁄2"

450 1⁄2" 1⁄2" 3⁄4" 1" 5⁄4" 5⁄4" 11⁄2"

500 1⁄2" 3⁄4" 3⁄4" 1" 5⁄4" 11⁄2" 2"

550 1⁄2" 3⁄4" 3⁄4" 1" 5⁄4" 11⁄2" 2"

600 1⁄2" 3⁄4" 1" 1" 5⁄4" 11⁄2" 2"

P

23

5⁄4"

Page 26: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Guide brackets

The main purpose of guide brackets is to support the pipe and allow the axial movement caused by the effects of expansion and contraction.

Application: For all fixations of Geberit HDPE pipes Ø40-315mm except for anchor brackets.

+B.362.826/001

+

+ +

Diameter Ø 40 –160 mm

+

B.362.837/001

B.362.826/001

1⁄2" 1⁄2" 1⁄2"

"1"1 1"

01M01MM10

Diameter Ø 200 –315 mm

OR

24

Page 27: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Spacing for brackets

Horizontal installation:

SA = max. 10 x Ø

Vertical installation:

SA = max. 15 x Ø

A = Anchor BracketG = Guide BracketSA = Spacing between anchor bracket and guide bracketSB = Spacing between guide brackets (see table below)E = Expansion socket

A

SB SA

Spacing of guide brackets SB:The table indicates the maximum distance between guide brackets (G) for Geberit HDPE pipes.

Nominal Spacingoutside of brackets (SB)diameterd Horizontal Vertical(mm) (m) (m)

40 0,5 1,2

50 0,8 1,2

56 0,8 1,5

63 0,8 1,5

75 0,8 1,5

90 1,0 2,0

110 1,5 2,0

125 1,5 2,0

160 1,5 2,0

200 2,0 2,0

250 3,0 3,0

315 3,0 3,0

max. 6 m

SB

SA max. 15 x Ø

A

G

G

G

A

Geberit HDPE pipes are to be fixed with anchor brackets (A) and guide brackets (G).

The distance between the anchor bracket and the first guide bracket must be respected as follows:

25

E A

Page 28: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

A Examples of installing Geberit HDPE expansion socket

Principal: Every pipe installation exceeding a certain distance (6 meters) must be protected against mechanical load with an expansion socket.

A Rainwater downpipe

Rainwater downpipes are generally not subjected to large temperature changes except for those outside of buildings exposed to sunlight.

In vertical pipelines the distance between the brackets can be calculated approx. as follows:

15 x pipe diameter

(max. distance see p. 25)

A = Anchor bracketG = Guide bracket

26

Page 29: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

B Examples of installing Geberit HDPE expansion socket

B Stacks

Not only does the HDPE expansion socket absorb thermal expansion and contraction due to temperature changes caused by water discharge, but it alsomakes pipe assembly easier, assisting connection at each floor level.

Rule: One Geberit HDPE expansion socketat each floor level

1. Free-standing stack with branch 2. Stack with branch in concrete

Anchor point

A

G G

A

G

A

G

A = Anchor bracketG = Guide bracket

27

Page 30: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

C Examples of installing Geberit HDPE expansion socket

C Horizontal suspended collector pipeline

When fitting collector pipelines extend 6 m it is necessary to fit expansion sockets and secure them with anchor brackets (see p. 23).Between the anchor brackets, guide brackets must be installed at the distanceSA or SB (see p. 25).

Rules: – Maximum distance between Geberit HDPE expansion sockets 6 m

– Inserting depth depending on ambient temperature– Anchor bracket directly on each Geberit HDPE expansion

socket– Guide brackets located along the collector pipeline

(see page 25).

Example

m 6 .xamm 6 .xamm 6 .xam

A = Anchor bracketG = Guide bracket

GGGG G G G G G

AA

A A A

28

Page 31: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

D Examples of installing Geberit HDPE expansion socket

D Combination of stacks and collector pipelines

Rules: – One Geberit HDPE expansion socket at each floor level– One Geberit HDPE expansion socket at each branch – One Geberit HDPE expansion socket at each change

of direction – Anchor bracket on each Geberit HDPE expansion socket.

Example

8 m

4,2 m

A

A

A

A

A

A

AA

A

A

8,4 m4,2 m

5,5 m

10 m

5 m

5 m

5,5 m

A = Anchor bracketG = Spacing between guide brackets in accordance to the rules (p. 25).

29

Page 32: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Principal: Any variation in length must be prevented by embedded fixed points (electroweld sleeve couplings, branches, bends or collar bushes) or by the provision ofcorresponding fixed point structures.

A Rigid installation with anchor brackets

Anchor brackets for rigid fixings must be stronger than possible expansion or contraction forces (P) of the HDPE pipe (see table).

Expansion and contractionforces

Geberit Ring- Column 1 Column 2HDPE pipe square (Normal installation) (Outside installation)

ca. + 20°C bis + 90°C ca. + 20°C bis – 20°Cd cm2 force kg force kg40 3,5 85 22150 4,4 105 27756 5,0 125 31563 5,8 140 36575 6,8 170 42890 9,5 240 598

110 14 350 882125 18,5 460 1165160 29,6 740 1865200 37,7 940 2375250 59,5 1490 3750315 93,9 2350 5915

Example:

This table shows that in the low temperature range (column 2) the forces are greater than in the high temperature range (column 1).

Prevention of thermal movement

30

Ø40–315

Page 33: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Anchor bracket for rigid installations

Rules: Anchor brackets must be stronger than the possible forces generated during thermal expansion or contraction of Geberit HDPE pipes.

Examples of anchor brackets

Dimension of pipe nipple or flat iron profile

Mounting plates

The examples of anchor brackets below show a typical rigid installation.

Anchor bracket with double electroweld sleeve coupling.

Anchor bracket with electroweldingtape.

Anchor bracket with flat iron and electrowelding tape.

Ceiling Geberit-Dimensionsor wall 50–56 63–75 90 110 125 160

WWWepiPecnatsidL · (mm) Ø Ø Ø Ø cm3 Ø cm3 Ø cm3

100 1⁄2" 3⁄4" 1" 1" 5⁄4"

150 3⁄4" 1" 1" 5⁄4" 5⁄4" 2"

200 3⁄4" 1" 5⁄4" 11⁄2" 11⁄2" 2"

250 1" 1" 5⁄4" 11⁄2 3,9"2"

300 1" 5⁄4" 5⁄4 2,11"2"2"

350 5⁄4" 5⁄4" 11⁄2 0,31"2"2"

400 5⁄4" 5⁄4" 11⁄2 0,510,9"2"

450 5⁄4" 11⁄2 8,611,01"2"2"

500 5⁄4" 11⁄2" 2" 9,5 11,3 17,7

550 5⁄4" 11⁄2" 2" 10,5 12,4 20,5

600 11⁄2" 11⁄2" 2" 11,4 13,6 22,4

These plates are dimensioned on the basis of stresses which they have to withstand (force P). Plates with 1" to 2" sockets can be provided on request.

The distance «L» and the thrustforce «P» have to be taken inaccount, when selecting the dia-meter of the pipe nipple betweenmounting plate and bracket. For therequired pipe nipple dimension seetable beside.

L L P L PP

100

W = indication coefficient for steel profile.

31

Page 34: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Embedded fixed points

Principal: Any variation in length must be prevented by embedded fixed points in concrete (e. g. electroweld sleeve couplings,branches, bends or collar bushes) or by the provision of corresponding fixed point structures.

B Embedding in concrete

Basically Geberit HDPE material absorbs within itself thermal movement due toits high elasticity. However, in the case of large diameters (e.g. 315 mm) the forces «P» (resultingfrom expansion and contraction) are considerable. They must be absorbed by the embedded fixpoints alone, since cement/concrete will not adhere toHDPE pipework.

Since the fitting has to act as a fixpoint, do not insulate it.

Under no circumstances should a ring seal or expansionsocket be embedded in concrete.

Reduced small branches of large pipe diameters must be securedby an additional anchor point (electroweld sleeve couplings orcollar bushes) to prevent shearingoff of the branch.

Branch equal Branch equal with reducer

32

Page 35: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

HDPE encased in concrete

Geberit HDPE pipes and fittings have been cast in concrete extensively throughout the world over the past 40 years.

Polyethylene as a raw material has the advantage of accommodating thermal expansion and contraction within the molecular structure due to its very high elasticity characteristics. The Geberit raw material is water rejectant and will not swell even when stored in water for very long periods.

The following information explains in detail the installation process as required by the relevant Standards.

Note: AS/NZS 3500.2:2003 specifies:Clause 9.4.3 High density polyethylene (HDPE) ...(iii) when fully encased in concrete structures, subject to the approval of a structural engineer, pipes and fittings shall be installed in accordance with the manufacturer’s installation instructions.

Note: AS/NZS 2033:2008 specifies:Clause 5.3.6 Encasement in concreteWhere pipes are to be encased in concrete precautions shall be taken to prevent movement, flotation or deformation of pipes while pouring concrete.

Setting of Geberit HDPE pipes in concrete

All rigidly jointed pipework (e.g. butt and electrofusion welded) may be completely enclosed in concrete within the building structure without a protection layer (e.g. lagging). The installation and the structure have to be designed for such total enclosure. The thrust forces generated from the expansion and contraction of the pipework have to be taken into consideration with this installation method (see Geberit Application Technique page 31). The manufacturer’s and engineer’s recommendations shall be strictly followed in such applications.

Note: Refer also to AS/NZS3500.2

For additional information contact Geberit Pty Ltd.

33

Page 36: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Cut pipe properly with waS ertiM dnaHrettuC epiP

Cutting surface must stay clean, therefore do not touch the cutting surface with your hands!

Cut pipe square!

Ø 40–160 mm Ø 200–315 mm

The allowance for butt welds is approx. as big as the wall thickness of the pipe

pipe diameter (mm) 40–75 90 110 125 160 200 250 315

butt weld s (mm) 3 4 5 5 7 7 8 10

Allowance for butt welds

34

Mounting instructionsGeberit HDPE butt welding – Preparation

Page 37: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Geberit HDPE butt welding by hand (for pipes Ø 40 – 75 mm)

Check temperature of the welding plate. Do not start with welding procedurebefore the green light is on.

1

Only press the pipe sections at thebeginning against the welding plate.Then hold without pressure.Watch melting process carefully.

2

When melted bulge is about as bigas a half of the wall thikness, takeoff both pipe sections simultane-ously and quickly press them carefully together.Increase welding pressure until youattain necessary pressure (see tablebeside).

3

Maintain the max. pressure until thewelding seam has cooled (approx. 30 secs. down).Do not accelerate the cooling down by contact with cold objects orwater.

4

Check visually the welding joint

Indicative values for welding pressure

Ø kg

40 6

50 7

56 8

63 9

75 10

Correct

False:out of axial alinement

Too high pressure at the start of the welding procedure

Unevenwelding heat

Indicative values for weldingand warming-up times

Wel

ding

tim

e in

min

.

Welding time

Warming-up time

5

4

3

2

1

0mm 2 4 6 8 10 Pipe wall

thicknessø 56 110 250

35

Page 38: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Geberit HDPE butt welding by machine(for pipes Ø 40 – 315 mm)

506375 11090

125160

TYPMEDIA 84

MASCH. NR.

Place pipe parts in the tension plates and fixthem in a line.

1

506375 11090

125160

TYPMEDIA 84

MASCH. NR.

1 cm 1 cm

Press pipe partslightly against theplaning disc andcut the ends until they arecompletly cleanand plane.Check the cutfaces by bringingthem together.

2

506375 11090

125160

TYPMEDIA 84

MASCH. NR.

506375 11090

125160

Melt pipe endswith weldingplate (green lighton) until the melted bulge isabout as big ashalf of the wallthickness de-pending on sizeof pipe.

3

506375 11090

125160

TYP

MEDIA 84

MASCH. NR.

Carefully presstogether bothparts with neces-sary welding pressure (seescale). Do not release the locking handle before the complete cooling(approx.40 secs.).

4

MEDIA40 – 160 mm

UNIVERSAL40 – 200 mm

Set of accessories200 – 315 mm

(for UNIVERSAL only)

506375 11090

125160

TYPMEDIA 84

MASCH. NR.

36

Ø

Ø

Ø

Page 39: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Geberit HDPE electroweldingPreparation

Cut pipe square

Dry, clean and scrape weldingends. Remove burr.Welding ends must remain dryduring the whole welding process.

ø 40–160 mm

ø 40–125 mm

ø 160–315 mm

3.5 cm3,5 cm

37

Page 40: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Geberit HDPE electroweld sleeve coupling(for pipes Ø 40 – 160 mm)

B.500.000/192

3 cm3 cm

Insert pipe or fitting ends into the sleeve coupling.

1

Right

Wrong

2

3

4

Connect electrofusion machine,start welding procedure.Welding time approx. 70–90 sec.

After the «END» indicator has turned on, remove the connectioncable. The protruding yellow indicator indicates whether the welding process was performed correctly.

If required for the sake of appearan-ce, the electrical connector socketon 40–160 mm dia. electroweldingsleeves can be removed after theend of installation work.

Geberit Electro fusion machine ESG 40/200

Electroweld sleeve coupling

000/191

38

Note: Electroweld sleeve couplings should not be welded twice. In exceptional cases wait at least 1 hour until the socket has completely cooled down prior to repeating the electroweld connection.

Page 41: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Geberit HDPE electroweld sleeve coupling ( 200 – 315 mm)

Dry, clean and scrape weldingends.Remove burr.Welding ends must remain dryduring the whole welding process.

1

2

3

Ø

4

5

Mark insertion length 75 mm.

Mount centering rings to ensure proper welding.

Insert pipe or fitting ends into the electroweld sleeve coupling.Connect start switch cable.Press start button briefly.Working temperature: –10 oC - +40 oC

Wait for at least 15 minutes after weld has been completed beforeremoving the centering rings.Do not remove the plastic sheet insulation until the sleeve has completely cooled down.

Geberit Start switch 230 V/50 Hz

Thermo sleeve coupling

Note: The same sleeve couplingcannot be welded twice , sincethe built-in thermo fuse shuts offautomatically after the necessarywelding temperature has beenreached.

Welding time:ca. 5 to 7 minures at 20 oC

39

Page 42: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Prefabrication

«Light weight» – easy tohandle

Wide range of fittings, excellent tools and the light weight of Geberit HDPE = perfect performance for prefabrication.

• The good characteristics of the Geberit HDPE offer an easy way to prefabricate pipe assemblies.

• Through the butt welding technique, the pipes and fittings can be easily connected to make many big combinations.

• Complicated labour at the site is eliminated by the clean and easy organizedwork at the workshop.

• Afterwards, at the site the prefabricated combinations can be assembled very fast.

Description

Advantages • Simplified work

• Easy time management

• Time saving

• Higher performance

• Higher quality

• Professional impression

• Short time at the site

• No loss of material

40

Page 43: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

10170

Prefabrication

Procedure Measurements (Preparation)Take measurements on site and mark the positions of all fixtures on thewalls and floor.

2.1 Using the isometrics method

Part Ø c–c ./. total

1 Pipe 110 450 140 3102 Pipe 63 620 430 1903 Pipe 63 765 188 5774 Pipe 63 .... .... ...5 .... ..... .... ... ...6 ...789

2.2 Using Geberit software

Design drawingPrepare the design and detailed drawing.

1

2

70 60 60 70 55

1614

41

Page 44: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Prefabrication

Cut pipe square

B.600.000/020

Prepare pipes and fittings

Shorten fitting

Weld pipes and fittings together with the Geberit welding machine MEDIA or UNIVERSAL.

Prefabrication of assemblies

The prefabricated assemblies can be connected on site with the electroweld sleeve coupling.

Installation on site

3

4

5

Jointing possibilities

42

Page 45: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Electric repair tool(Art. No. 359.048.P0.1)

Clean repair area well withscraper, knife or emery cloth.

1

Screw suitably sized insertonto front or side of heater.

2

"BARY"

Kunststo-Schweissapparate

Type: A-Volt 2

30Watt Nr. W.Riesen Basel (S

chweiz)

Dittingerstra

sse 45

Heat simultaneously repairarea and patch.

3

Press softened patch quicklyonto repair area.

.retaeh eht naelC.liat gnitcejorp fo tuC

4

5 6

"BARY"

Kunststo-Schweissapparate

Type: A-

Volt 230

WattNr.

W.Riesen Basel (Schweiz)

Dittingerstrasse45

Repairing holes in HDPEpipes and fittings and in PEconcealed cisterns

43

Page 46: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Thermal expansion sockets (application in buildings)

Mounting instructions

Prepare pipe insertion end.

1

Mark insertion depth on the pipe. Consider outside temperature.

2

Remove yellow protection cap.

3

Lubricate pipe end and rubber seal. Only use soft soap, Silicone orVaseline. Do not use mineral oil or grease !

4

Push the pipe into the expansionsocket.

5 On the building site, protect the seal fromingress of dirt. Wrap a felt bandagearound and secure with adhesive tape.

6

at 0°C (32°F) at 20°C (68°F)

Important: Fix each expansion socketwith an anchor bracket !

Please note:

The marking of the insertiondepth and the assignedlength of pipe on the expansion socket does notapply for buried pipes, unlessthe same temperature fluctua-tions as in the building draina-ge system are anticipated.

maximal pipe length: 6 m !

8 cm 10,5 cm

44

Page 47: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Special application fieldsUnderground drainage pipes for housing

Underground drainage pipes of Geberit HDPE

Not only has Geberit HDPE provenitself excellently for many years fordrainage systems inside of buildingssuch as:– soil and waste stacks– vent pipes– connection and branch pipes– collector pipes

but it is also suitable for under-ground applications as:– ground pipes– domestic drainage pipes

Criteria for underground drainage pipes

1. Tightness

Environmental protection regulations do not permit leaking drainagepipes.

Geberit HDPE is a reliable water drainage system which assures maximum dependability with regardto tightness.

2. Resistance to chemicals

Geberit HDPE provides the assu-rance of universal resistanceto the greatly diversified types ofchemical attack by the disposalwater, as well as by external factors(acidic soils).

3. Flexibility

Geberit HDPE is a flexible, operatio-nally reliable drainage system, evenin soils in which a certain degree of settling of ground must be anti-cipated.

4. Resistance to frost

Geberit HDPE has proven itself excellently for many years in frost endangered soils such as in Scandinavia. It can be used in tem-peratures ranging down to –40°.

5. Material

As in domestic drainage systems,the quality of the material is themain criterion for underground

applications. In addition to theattack from the inside, the pipesare also subjected to attacks fromoutside. Geberit HDPE excellentlystands up to all these requirements.

1 Ground acids 2 Stray currents3 Disposal water (with chemical

and thermal attack)4 No enter of roots

6. Friendly to the environmentThe Geberit HDPE drainage systemscomply with environmental regulations.

13

2

4

45

Page 48: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

D

10 cm

B

A

D

A=D + min. 100 mm

Trench profiles

Important for underground installa-tion is correct laying of the pipe in thetrench, as well as careful consolida-tion.

B = Bedding The pipe must have a bedding of atleast 100 mm.

C = Consolidation Side fill to upper edge of pipe.

P = Protective layerWith trench profile 1A cover toabove top edge of pipe over entirewidth of trench min. 300 mm

HS = Safety heightWhen using mechanical compac-tors:Vibration compactor

1,000 N HS = 0,4 mVibration roller

3,000 N HS = 0,3 mVibration roller

15,000 N HS = 0,5 m

D = Consolidation stratum depthmin. covering: In area of road 0,8 m Outside road area 0,5 m

Max. covering: Up to 6 m without problem

In cases of minimum coverings or heavy loading, measures such asload distribution plates or appropria-te trench profiles are to be used.

Traffic loadsHeavy traffic P = 9 tonsNormal traffic P = 6 tons

Away from roads:always P = 3 tons

Filling materialGrain size Round gravel 0 = 30 mmBroken material 0 = 10 mm

min. 60 cm

20 cm

D

HS

P

C

B

Profil V1A

Behavior: flexibleEmbedmentRound gravel 0 – 30 mmBroken material 0 – 10 mm

10 cm

B

A

Profil U4A

Behavior: rigidEmbedmentin concretePC 200 kg/m3

Profil U4B

Behavior: rigidEmbedmentin reinforced concretePC 250 kg/cm3

20 cm

HS

P

C

B

Profil U1A

Behavior: flexibleEmbedmentRound gravel 0 – 30 mmBroken material 0 – 10 mm

For all trenching work, local guidelines, standards and regulations must be observed.

46

Page 49: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Guidelines for laying drainage pipes

TrenchThe trench is to be dugas narrow as possible –but not narrower than thepipe diameter + 40 cm.The floor of the trenchmust be level and freefrom rocks and looseclumps. Correct elevationand slope are also impor-tant.

1 B = Bedding Under normal soil condi-tions the trench is provi-ded with a bedding layerof round gravel (gradingup to 30 mm) or of bro-ken material (grading upto 10 mm) of a thicknessof approx. 100 mm. Thebedding layer must becompacted and tamped.In certain cases it will beneccessary to reinforcethe ground.

2 U = Underpinning After the pipe has beenlaid, recesses are to beprovided for sockets andflanges so that the pipe issupported along its entirelength. The underpinning isto be done with a tampingpost or the like. It must bedone very carefully. If seve-ral pipes are laid, makesure that the lowest one isfully covered before theone above is placed. Thepipe must lay flat, and itmust be installed with thecorrect slope.

3 C = Consolidation layer The material is to be filledin layers of approx. 100mm thickness. Tampingcan be done by stampingwith the feet, or with aspecial tool. The purposeof this material is to helpprevent the pipe fromdeforming, so that it mustbe compacted well onboth sides at the sametime .

4

1

2

P = Protective layer Now fill in a layer of thesame material (must notcontain rocks whichcould cause point loadingof the pipe) of at least300 cm. Attention: To prevent thepipe from rising thetrench is to be finish-filledon the same day up toand including the protec-tion layer.

5 HS = Safety marginheightFor the further filling the available material is to beused. The trench must notcontain rocks which can-not be lifted by hand.As soon as permitted by the safety margin height, this compacting can be done by machine. Theregulations and byelawson the refilling of trenchesare to be observed.

6 Distribution of ground pressureThe ground pressure and ground load distribution are gover-ned essentially by thecompaction. For calcu-lation the appropriatestandards and the local building and safety regulations are to beobserved.

1 Ground load and possible traffic load

2 Shoring pressure

For all trenching work, local guidelines, standards and regulations must be observed.

BU C

P

HS

47

Page 50: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Inground rigid installation

Rigid fixation The rigid fixings must be stronger than the possible expansion or contraction forces of the HDPEpipe.

Geberit pipes can be installed rigidly with relatively low effort, forwhich the following elements arerequired:

1 Concrete mound as an anchor point

2 Electroweld sleeve coupling 3 HDPE pipe

48

1

3

Page 51: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Please note:The indicator found on the socketdoes not apply in case of inground installations.

Inground installation ofGeberit expansion sockets

In addition to the butt-welded and electrically welded connection, the expansion socket is an idealconnection in inground drainagesystems. Since in such systems lower temperature differences areusually encountered than in stacks and connector pipes, smaller length variations can be accounted for.

Therefore, in inground installations,the distance between expansionsockets can be longer.

The values are calculated accor-ding to the formula

SL – (0.3 • d)0.006

and rounded off.

Nominal Socket Pipe length Insertionoutside length SL PL (for ∆t depth IDdiameter ≤ 30°C)d (mm) (mm) PL (m) (mm)

110 140 15 130

125 140 15 130

160 140 15 130

200 220 20 230

250 220 20 230

315 220 20 230

Installation of the inground expansion socket

Insert beveled pipe to maximum socket depth, mark and pull back 40 mm.

Prepare the pipe end

The pipe end should be chamferedand lubricated with soap to easeinserting.

d

ID (insertion depth)

PL (pipe length)

SL (socket length)

PL

4cm 4cmID

49

PL ≤

Page 52: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

With regard to the ground line between the building wall and the street sewer, where extreme settling can occur, an installation mat must be wrapped around the ground line to act as a deflection leg.

In such cases Geberit HDPE is an ideal material, since it assures tightness and at the same time provides maximum flexibility.

Deflection leg The length of the deflection leg is dependent upon the expected settling and on the pipe diameter.

Length DL = 10 · |/ ∆ S ·

Note: The insulation must be thicker than the expected settling.

Pipes penetrating through building walls

ø

Expected settling GeberitHDPE pipe Deflection leg∆ LDØS20 – 40 mm 125 – 160 /200 – 315 1,0 m /1,0 m40 – 60 mm 125 – 160 /200 – 315 1,0 m /1,5 m60 – 80 mm 125 – 160 /200 – 315 1,5 m /1,7 m

1 See page pipe2 Settling3 Insulation mat4 HDPE pipe (Ø)5 Foundation slab6 See page liningDL = Deflection legS = Insulation thickness∆S = expected settling

H

d

D

LExamples for water proofing see p. 18

50

Page 53: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Connection to manhole

Open manhole

Access pipe with oval access cover

Plastic pipes should only be connected with manholes bymeans of a special manhole sleeve. Since settling of ground has to beexpected such a sleeve must have the same ideal characteristics as Geberit HDPE: it must assure tightness and at the same time fle-xibility.

A rubber ring provides the flexibleseal between sleeve and plasticpipe.

1 Concrete2 Manhole sleeve 3 Geberit HDPE pipe4 Bench5 Anchor point if required

1 Concrete

2 Manhole sleeve

3 Access pipe (Art nr. 3xx.454.16.1)

Geberit access pipe with oval access cover

51

1

2

3

Page 54: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

52

Toilet

Basin Toilet

Toilet

Floor Waste

Floor Waste

Toilet

Fittings

H≥DI

H≥DI

Stack

The Geberit ball junctions allow designers and plumbers the opportunity to create compact installations. The increased diameter of the intersection area provides for a smoother and less critical side entry of the waste water into the stack. In particular, installations where the branch lines have the same diameter as the stack.

Connections directly opposite, (180°) should be avoided where possible. However such installations must be carried out only in accordance with the guidelines items 2 and following below. A better way of connecting is by using the offset ball junctions. Geberit ball junctions are designed for the application in stacks only and should not be used as back to back toilet connectors nor should any stack be connected to a side entry.

1. The offset ball junction is generally the best way of connecting different types of fixtures to the stack. Fixtures of different types, unequal fixture unit rating and different diameters should only be connected on the opposite side of a ball junction at an entry angle of not more than 135°.

2. Connections directly opposite (180°) on a ball junction should only be used for connecting fixtures of the same kind or with the same fixture unit rating and same pipe diameter (eg. soil fixture opposed soil fixture, waste fixture opposed waste fixture).

2a. It is essential to observe the arrangement of directly opposed connections. Geberit does allow the following exceptions (subject to local authorities approval):

Refer to item 6., figures 1, 2, 3 and 4 (page xx) over the page.

3. Any fixture trap connected to a ball junction should have a minimum height difference of the inside diameter (DI) of the connecting pipe. This is measured from the lowest point where the pipe is joined onto the stack to the water seal of the fixture trap. See 3.1, 3.2, 3.3, for examples.

3a. This can be achieved via a step up in the pipe work with appropriate fittings before the fixture trap (see drawing opposite).

3b. If the total gradient (height difference) of the pipe work from stack to the water seal of the fixture trap meets the required height difference.

Note: The maximum allowable gradient or distance to the stack should not be exceeded.

3c. If there is more than one fixture connected to the same line, the requirement as outlined in 3 must be met for each fixture trap.

Toilet

Basin

Basin

Basin

ToiletToiletToiletToiletToilet

Ball Junctions

Stack

H≥DI

H≥DIH≥DI

Stack

Page 55: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

4. All branch line connections to a ball junction should be made with concentric reducers at the same centre line.

5. No stacks should be connected to the side entry of a ball junction.

6. Installation Recommendation (SN 592000)

53

Ball Junctions

Note: AS/NZS3500.2 amendment 3 2010 clause 6.6.1, 6.6.2 and 6.6.5.1. In Australia currently some local authorities ask for additional restrictions or do not allow the use of ball junctions at all. Enquire directly with the appropriate authority prior to starting any planning or installation.

Centre line

Stack

Concentric Reducer

Clause 6.6.1

Any of the following types of junctions may be used to connect fixture, branch or common discharge pipes to a stack, the following apply:

(a) 45° junctions.(b) Sweep junctions.(c) Aerator junctions.(d) Ball junctions.(e) Square junctions.

No fixture shall be connected to the branch or common discharge pipe within 500mm in length from the stack if the entry is at grade.

Clause 6.6.2

Where any fixture trap is connected to a ball junction, the weir of the fixture trap shall be at the same height or above the top of the branch junction fitting.

Where a square or ball junction is used and any discharge pipe is less than 500mm in length from the stack, one of the following shall apply:

(a) A self-sealing device shall be fitted to the fixture.(b) An S-trap shall be fitted to the fixture and a vertical dropper provided in the discharge pipe between the fixture and the stack junction.(c) A P-trap shall be fitted to the fixture, and the discharge pipe graded at not less than 6.65% (1 in 15).

Clause 6.6.5.1

Opposed connections at ball junctions or aerator junction fittings may be used only where the opposing pipes are connected to equal numbers of the same type of fixtures.

Opposed connections, other than at ball type junctions or aerator junction fittings, shall only be made using double 45° junctions or double sweep junctions.

Page 56: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Low pressure installation

Low pressure application

Discharge pipeline of a pump set

Generally the Geberit HDPE product range is designed for water drainagesystems. For the low pressure range, e. g. swimming pool, pipework through circulationpumps, Geberit has established maximum admissible stressing values for anendurance life of 10 years.

Pressure max. 1,5 bar

Temperature max. 30°C

Longtermrupture strength 10 years

All connections must be butt weld joints, electroweld sleeve couplings or flange joints.

Suitable fitting range for low pressure application see page 4.

The Geberit HDPE range of products can also be used for the discharge pipeline of a pump set, provided that the mechanical stress is low, only of shorttime and no thermal loaded medium (e.g. warm water) is pumped.

When designing discharge pipelines for drainage pumps the following importantpoints should be observed:

1. The discharge pipeline has to be installed higher than the lowest installedappliance by means of a pipe loop.

2. If the flow rate is smaller than 5 l/s the vertical fall section of the pipe loophas to be increased.

3. If the flow rate is above 5 l/s the vertical stack has to be vented with aventilation pipe of at least 50 mm inside diameter.

4. Long horizontal collector pipes have to be vented. The minimal inner diameter of the vent pipe must be 57 mm or 2 dimensions smaller thanthe discharge pipe.The ventilation pipe must be higher than the total delivery head of thepump and must go above the roof.

Pumpedpressurepipeline

Vertical stack

Vertical stack

PumpedpressurepipelineV· > 5 l/s

Vent≥ 50/56

Side vent≥ 50/56

Collector pipe

Pumpedpressurepipeline

Vertical stack

Collector pipe

Pumpedpressurepipeline

Vertical stack

Collector pipe

Vertical discharge stackPumped

pressurepipeline

Vent ≥ 50/56 Side vent≥ 50/56

Collector pipe

54

Page 57: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

External pressures Internal negative pressures

External pressures

Permitted external pressures

Geberit HDPE pipes will withstand external pressures according to the tablebelow depending on the pipe diameter.

The maximum level of the groundwater table has to be taken into account whendesigning Geberit HDPE pipelines in a groundwater area.

Internal negative pressures Geberit HDPE pipes will withstand internal negative pressure according to thetable above depending on the pipe diameter.

Geberit HDPE pipes are sometimes used as suction pipelines for pumpsets. The higher the suction lift is, the higher the negative pressure inside the pipeline.Important with such an installation is that the foot valve and strainer are notblocked. Foot valve and strainer of the suction pipeline should be kept free from debris,possible blockage could lead to additional pressure increase.

Pipe Wall thickness External pressures (mm) bar m Water column

40 3 2,5 25,5

50 3 1,4 14,3

56 3 0,82 8,4

63 3 0,64 6,5

75–160 3–6,2 0,36 3,7

200–315 6,2–9,8 0,18 1,8

For adequate fittings see page 4

Permitted internal negative pressures

Pipe Wall thickness Internal negative pressures (mm) bar

40 3 1,0

50 3 1,0

56 3 0,82

63 3 0,64

75–160 3–6,2 0,36

200–315 6,2–9,8 0,18

For adequate fittings see page 4

55

Page 58: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Fire protection

Depending on the type of building different fire protection will be required. Observe and follow BCA, standards and regulations!

Building partsThe requirments for buildingcomponents are classified in fireresistant classes in order to maintain maximum integrity ofthe relevant wall, floor or ceiling.

The weakening of a fire protection wall or ceiling is not allowed underany circumstances.

The integrity of the wall or ceilingwill be maintained for the permitted periods when Geberit fire stoppersare used as illustrated.

Passing through wall andceiling

Installation and time of fire resistance

Gr. 10 Gr. 10

Installed on the ceilingFire class F 90

Installed on both sides of the wall Fire class F 120

Use only for:

1211

109

8

7 6 5

43

2

1

STOP!90 Min

1211

109

8

7 6 5

43

2

1

STOP!90 Min

56

1211

109

8

7 6 5

43

2

1

STOP!90 Min

Page 59: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Physical characteristics of Geberit HDPE

Physical characteristics of Geberit HDPE

The data given below was obtained with test specimens of pressed plates and foils. Individual values can deviate from these average values depending on the conditions under which the test specimens were made.

nemiceps tseTdohtem tseTtinUcitsiretcarahC

etalP97435NID3mc/gytisneD 0,953...0,955

0,3noitulos %1,01911 R/OSIg/ldcificeps decudeRviscosity (viscositycoefficient) in decalin

7,0...4,0etalunarg53735 NID.snim 01/g5/091 IFM xedni wolf-tleM

Mechanical characteristics, measured under standard climatic conditions 23°C, 50% relative air humidity**

223 nemiceps tseT/OSI .55435 NID2mm/Nhtgnerts elisneTElongation at yield stress % R 527; test velocity with measurements 15

234:1 oitar eht ninim/mm 5212mm/Nhtgnerts elisnet etamitlUElongation at break % > 800

82rab llams dradnatS25435 NID2mm/Nhtgnerts gnidneb timiLinjection moulded

042mm 2 x mm 53,6 x mm 0674435 NID2mm/Nytidigir lanoisroTBending creep modulus N/mm2 Bending creep test 120 mm x 20 mm x 6 mm 8001 minute value οb 3 N/mm2

04mm 4 ,teehS65435 NID2mm/Nssendrah noitatnednIN4 ,231 htgnerts tseTeulav dnoces 03

06mm 4 ,teehS50535 NID—D ssendrah erohS51***dedluom ,rab llams dradnatS35435 NID2mm/Jmhtgnerts tcapmI

noitcejni ,rab llams dradnatS35435 NID2mm/Jmta htgnerts tcapmI+23°C and –40°C moulded

Thermal characteristics

Crystallite melting range °C Polarisation microscope Microtome section 127...131Mean linear expansion K–1 DIN 52328; ASTM D 696 50 mm x 4 mm x 4 mm 1,7·10–4coefficient between 20° and 90°C

W 34,0mm 8 ,etalPdohtem teehs 21625 NIDK · mC°02 ta ytivitcudnoc taeH

Injection, moulded

Electrical properties, measured under standard climatic conditions of 23°C, 50% relative air humidity

6101>mm 2,0 ,lioF28435 NIDmc ·Ωecnatsiser noissimsnart cificepSVDE 0303 Part 3

3101>mm 1 ,teehS28435 NIDΩecnatsiser ecafruSVDE 0303 Part 3

007mm 2,0 ,lioF18435 NIDmc/Vkhtgnerts cirtcelEVDE 0303 Part 2

Dielectric index εr,(relative dielectric constant)

05,2mm 2,0 ,lioF3030 EDV ,38435 NID—zH601 2 taPart 4 (immersion method)

mm 2,0 ,lioF3030 EDV ,38435 NIDrotcaf ssol cirtceleiDtan δ 4–01 · 64 traP—zH 05 ta

103Hz — 5 · 10–4104Hz — 5 · 10–4105Hz — 6 · 10–4

c3 AKmm 3≥ teehS084 35 NIDecnatsiser kcarT006 > CK1 traP 3030 EDV

4Lmm 01 x mm 021 x mm 02148435 NIDecnatsiser crAVDE 0303, Part 5

In a number of countries, a tensile test The values given above relate exclusively In contrast with injection, mouldedis carried out on a test specimen taken to the corresponding test methods or specimens are free from flow in longitudinal (or transversed) direction test specimens. Results which are orientations. This strongly influences of the pipe, e.g. in Great Britain obtained with specimens taken from the test result.

si srab dedluom htiw tnemerusaeM.eerga ton yam sepipseulav ehT .4823 SB ot gnidrocca.derreferp eroferehtylirassecen ton od deniatbo ybereht

need to agree with those given in thetable, which applies especially for theelongation at break.

57

Page 60: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Ecological properties of Geberit HDPE

Polyethylene (PE) is a simple compound of carbon and hydrogen atoms, harmless to man, animals and plants.

PE is the perfect material for drainage systems from an ecological point of view. It has a long life span, no toxic gases rises from incineration (e. g. hydrochloric acid HCL from PVC) during disposal. It consumes much smaller quantities of energy during fabrication process and transport than steel, cast iron or cop-per pipes.

58

PE environmental loads relate to the fields of manufacture and disposal. In addition to the raw material crude oil, energy is used for the preparation of the plastic granulate and in the manufacture of the products.

Fore more information about environment and sustainability, please order ourreportLife Cycle AssessmentDrainage pipes for buildings

Page 61: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Ecological properties of Geberit HDPE

Environmental impact of different pipe material(Ecobalance)

The diagram shows the environmental impact of 1 m pipe Ø 110 during itsexpected life, beginning with its raw material and ending with its disposal.

The environmental impact is measured in environmental points (UP), accordingto the regulations of the Swiss Federal Office of Environment, Forest andCountryside (BUWAL), Publication series 132 and 133.

7000UP/m pipe

0

1000

2000

3000

4000

5000

6000

Cast iron50%recycledtin plate

Cast iron100%recycledtin plate

PVC ABS HD-PE

Disposal of pipes

Manufacture of pipes

Manufacture of raw material

59

Jenni
Typewritten Text
Jenni
Typewritten Text
Jenni
Typewritten Text
Jenni
Typewritten Text
Page 62: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Comments on the individual properties

Geberit High Density Polyethylene HDPE: Density 951 – 955 kg/m3 The density of various polyethylene types can be 910 – 960 kg/m3. The Geberit typeat up to 955 kg/m3, is of the hard quality and has increased durability properties.HDPE is lighter than water, which is beneficial particularly with regard to transportationand installation.

Tempered 10 mm per meter (licence Geberit International AG)The safest way of avoiding the inevitable heat reserves (shortening of dimensions) afterheat load in the plastic pipe, is to take preventative measures during manufacture. Geberit HDPE pipes are therefore stored in hot water baths after manufacture. This process increases the safety of the joints, as there is no chance of joints pullingapart later due to shortening of length.

Resistance to cold When Geberit HDPE parts are filled with water and then freeze, they stretch elasticallyas the ice expands. Once the ice melts, they resume their original shape, remainingcompletely intact and undamaged.

FlexibilityThe flexibility of the piping material can be the main criterion in certain buildings or onbridges, especially when pipes have to pass through expansion joints or are in buildings, which are subject to traffic vibration.

Melt-flow index 0,4 – 0,5 g/10 min. This describes the working properties of the pipe and at the same time gives information on the molecular weight, which is crucial for a number of raw material properties. The smaller the melt-flow index, the higher the molecular weight and thusthe pipe’s resistance to stress corrosion.

Heat conductivity 0,43 W/m · K HDPE is a bad heat conductor; for this reason the pipe does not become completelywarmed through when heat loaded for a short period. Heat loss is about 90% less, for instance, than a similar copper pipe.

60

Page 63: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Comments on the individual properties

Heat expansion 0,17 mm/m · K Heat expansion of HDPE is relatively high. As a rule of thumb, for every 50°C increasein temperature, an expansion of 10 mm of linear meter of pipe can be anticipated.

Resistance to hot water Geberit HDPE can be safely used as waste pipe with no mechanical load, up to 80°C.Temperatures of up to 100°C for short periods (e.g. surges of steam) are permissible.

Resistance to impact Geberit HDPE is unbreakable at room temperature. Its resistance to impact is very high even at extremely low temperatures (down to approx. –40°C) and thus meets the requirements for outlet pipes.

CondensateGeberit HDPE is a poor conductor of heat. No condensate should form during short periods of undercooling.

Resistance to radioactive effluents There is no risk of damage as a result of slightly radioactive water. However, pleaseask the manufacturer for more information relevant to the particular application.

Resistance to abrasion Drainage systems are increasingly becoming hidden refuse chutes. A pipe’s resistanceto abrasion is a particularly important factor in branch pipes, soil stacks and ground pipes. HDPE is highly resistant to abrasion; its extra thick walls offer additional protection.

61

Jenni
Cross-Out
Page 64: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Comments on the individual properties

Non-conductivePlastics have an excellent reputation as insulators in the electronics industry. HDPE cable protection ducts, cast resins, insulating paint etc.

Sealing material Although the chemical resistance of the seal does not equal that of HDPE, there is norisk of the seal being destroyed, because the rubber ring is installed under com-pression on all sides and therefore cannot swell. In addition, the wetting factor of therubber ring in the joint is very low. Many years of experience have shown that the sealing material can endure even the harshest conditions. NB: Such conditions do not occur in drainage pipes. Free halogens (chlorine, bromine etc.) cause halogenised polyethylene and hydrogenhalide to form at room temperature. The halogenised polyethylene has different physical and chemical properties from the original hydrocarbon, but the polymer is not destroyed. Geberit HDPE should therefore not be used at all in areas where free halogens are produced or used. The only criteria to be observed here are the purposefor which the pipe is intended and the concentration of halogens.

Solar radiation Geberit HDPE pipes are protected against ageing and embrittlement caused by UVrays by the addition of approximately 2% soot.

NoiseHDPE is a soft material with a low E-modulus. HDPE limits solid-borne conduction, but airborne noise should be insulated. This can be done by means of the duct wall,HDPE Silent or Geberit Isol.

Chemical resistance Because of its paraffinic structure, Geberit HDPE is highly resistant to chemicals. Its resistance can be summarized briefly as follows: Geberit HDPE is insoluble in all inorganic and organic solutions at 20°C. Geberit HDPE is only soluble in aliphatic andaromatic carbons and their chlorinating products at over 90°C. The material will be attacked by heavily oxidized media (conc. HN03, conc. H2 S04) when exposed overlong periods at room temperature.

Behaviour in fire Plastics are inflammable. However, the classification of plastics according to the usual fire test for construction materials does not permit a valid statement on the behaviourof plastic construction parts in the event of a fire.

62

Page 65: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Comments on the individual properties

Protection against blockages HDPE’s water-repelling properties are highly beneficial in this regard. – Rapid outflow of water – Prevention of deposits

Welding temperature Thermoplasts are processed with a high level of energy efficiency. The temperaturesrequired are relatively low in comparison with metals. The welding temperature for HDPE is approximately 230°C. Simple tools allow for easy processing.

Non-toxicPlastics are well suited for use in the food industry as packaging material, containers,bottles etc. Geberit HDPE pipes are used for milk transportation lines in mountainareas and in the food canning and packing industry.

Scope of use Geberit HDPE pipes are designed for drainage systems. Their use in low-pressureareas (swimming pools, transportation lines etc.) is subject to a maximum pressure load of 15 m Water Column (1,5 bar) and a temperature of 30°C (10 years). There is also a certain range of moulded fittings.

PaintingGeberit HDPE is not suitable for painting. Its water repellent properties and the flexibili-ty of the material both have a negative impact on paint. If painting is unavoidable, thepaint product to be used should be tested for compatibility with the HDPE.

TightnessMany years of experience with welding HDPE-Pipes, have shown that the butt weldsdo not give any problems as the welding parts are circular on the inside and do notadd to the normal risk of blocking.

63

Page 66: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

The importance of tempering

Manufacturing process ofHDPE pipes

As a result of manufacturing, the molecule chains are stretched and than cooled down from about 230°C to 40°C. This enormous drop in temperature results in tensile stresses which are «frozen in» by the coolingdown process.

When hot water flows through a streched pipe or the pipe is heated up by doing a welding joint, e.g. with an electroweld sleeve coupling, the expanded molecules relax and return to their normal state. The pipe becomes shorter.

Stretched molecules after manufacturing(non tempered pipes)

Without tempering, shortening of dimensions can create gaps between pipeand fitting, pipes can be pulled apart

1 Driving motor 4 Screw 7 Gauging device 9 Drawing device2 Raw material 5 Electric strip heaters 8 Cooling bath 10 Finished pipe3 Extruder 6 Mould

high risk of leakage!

64

Page 67: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Length = 5000 mm

Effects of annealing of Geberit HDPEpipes

Molecules after Geberit annealing process(all Geberit HDPE pipes)

The safest way of avoiding the inevitable heat shortening of dimensions afterheat load in the plastic pipe is to take preventative measures (Tempering)during manufacture. Geberit pipes are therefore stored in a hot water bathafter manufacture, this allows the expanded molecules to relax and return totheir normal state = No stresses on Geberit pipes.

Tempering of Geberit pipes reduces mechanical stress on joints and fixations. Through this process even the high precision requirements forelectroweld sleeve couplings can be met.

After manufacture

Admitted shortening according to standards 150 mm

Max. admitted shortening according to Geberit licence 50 mm

The importance of tempering

65

Jenni
Typewritten Text
Jenni
Typewritten Text
Jenni
Typewritten Text
Page 68: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

slightly acid

The significance of the pH value

One of the most crucial factors in selecting a material for a drainage installationis the chemical loading of the effluent being discharged.

Effluent with a low or a high pH is harmful because of its corrosive effects. E. g. some drain cleaning fluids have a pH value of up to 12.

Therefore in order to select the most suitable material to handle a specificdischarge it is important not only to know the pH value of the effluent but the chemical resistance of the pipe materials. (see Chemical Resistance tables on pages 67 to 76 to assess the performance of Geberit HDPE at various temperatures)

The pH value is therefore important in assessing the chemical level as it will indicate whether the effluent is acid, neutral or alkaline. The pH scale ranges from 0 to 14 (see table below). PH valve 7 neutral.

increasingly acid increasingly alkaline

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

very acidslightlyalkaline very alkaline

NE

UTR

AL

HDPE . . .

. . . can be used safely with pHvalues from 0 to 14.

. . . is therefore suitable, forexample, for use with effluents containing over30% hydrochloric acid.

pH values of some drinks andcleaning agents

pH-valueCola drinks 2,8Apple juice 3,5Tartaric acid 2,2Citric acid 2,8Washing solutions 9 –13Toilet cleaner 2 – 4

66

Page 69: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Chemical resistance list

67

Page 70: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Chemical resistance list

Explanation

When the pipe wall material comes into contact with substan-ces flowing through the pipe, different processes can takeplace, such as the absorption of liquid (swelling), the extractionof soluble elements in the material (shrinkage) or chemical reac-tions (hydrolysis, oxidation etc.), which can sometimes causethe properties of the pipes or pipeline parts to change.

The performance of pipes and pipeline parts when in contactwith effluent substances can be classed as follows:

Resistant The pipe wall material is generally regarded as being suitable

Limited resistance The suitability of the pipe wall material must be checked ineach individual case; if necessary, further tests should be carried out.

Not resistant The pipe wall material is generally regarded as being unsuitable.

The following symbols and abbreviations are used to indicatethe composition of the flow substances:

% Percentages refer to mass proportions in %.

VL Aqueous solution, mass proportion <= 10%.

L Aqueous solution, mass proportion > 10%.

GL Aqueous solution saturated at 20°C.

TR Chemical is at least technically pure.

H Normal commercial composition.

S Traces < 0,1%

G Usual mass proportion of any saturated solution or dilution.

Data is based on immersion tests without mechanical load andreflects current levels of knowledge. No claims under guaranteemay be made on the basis of this information.

A04edyhedla citecARTedyhedla citecA

Acetic aldehyde+acetic acid 90:10Acetanhydride (acetic anhydride) TR

RTedimatecARTedirdyhnatecA07dica citecA001dica citecA

Acetic acid butyl ester001)etatecalyhte( rehte citecA

Aceto-acetic acidLVenotecARTenotecARTenonehpotecA

AcetyleneHsnoisrepsid lanorcAHsnoitulos lanorcA

RTelirtinolyrcAAcrylic acid-emulsions

001retselyhte dica cilyrcAActivine (chloramine 1%)

LGdica cinipidAAdipinis acid esterAllyl acetate

69lohocla lyllAAllyl chlorideAlum (potassium aluminium sulphate) any

LVedirolhc muinimulALGedirolhc muinimulA

Aluminium chloride, solidLGediroulf muinimulA

Aluminium hydroxideAluminium metaphosphate

ynaetahplus muinimulAAluminium sulphate, solidAmidosulphates

(amido-sulphonic acid salts) anyynadicacinohplus-odimA

Amino acids001suoesag ,ainommA001diuqil ,ainommA

Ammonia solution (ammonium hydroxide) anyynaetateca muinommA

Ammonium carbonateand bicarbonate of ammonium GL

ynaetanobrac muinommAAmmonium chloride (sal-ammoniac) anyAmmonium dihydrogen phosphate GL

Lediroulf muinommAAmmonium hydrosulphide anyAmmonium metaphosphate

ynaetartin muinommAynaetahpsohp muinommAynaetahplus muinommAynaedihplus muinomA

Ammonium thiocyanateRTetateca lymARTlohocla lymA

001edirolhc lymAAmyl phthalate

LG)enimalynehp( nilinA

The following data is required for a declaration of chemical resistance:

– Corrosion medium, composition (chemical description),DIN safety data sheet

– Temperature

– Proportion (concentration)

– Information on reaction time, frequency, flow quantity

– Other flow media

Geberit HDPEProport. Performance

02%ecnatsbus hguorht wolF ° ° 60

68

40 °

Page 71: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° ° °C

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° ° °C

A ynaetardyhrolhc nilinA RTlio esinA RT)enonaxeholcyc( enonAnthraquinone sulphonic acid 1Antifomine (benzaldoxime) 2A Hezeerf-itnAntimonious trichloride, anhydrousA 09edirolhcirt suoinomitnAntimonious pentachlorideA Heciuj elppA Heniw elppA RTaiger auqArklone (= reon, frigen) (Chloro fluorcarbon CFC) 100Aromativ oilsA ynacinesrArsenic acid anhydrideAscorbic acid (vitamin C)Asphalt

BBarium carbonate

chem. precipitated 98/99% anyynaedixordyh muiraBynastlas muiraB

Battery acid (sulphuric acid,~34%) H001tnega gnitarapes nolisyaB

Beef fatBeef suet

HxawseeBHreeBHgniruoloc reeB

ynaedyhedlazneBBenzaldehyde in isopropyl alcohol 1

RTenezneBBenzaldoxime (antiformine) 2Benzene/benzol mixture 80/20Benzene sulfonic acid

ynadica ciozneBRTedirolhc lyozneBRTlohocla lyzneB

Benzyl chlorideBichromate sulphuric acid

(chromic acid/sulphuric acid) TRBismuth nitrate, acqueous anyBismuth saltsBisulfite solutionBitumenBleach solution with 12,5% active chlorineBone oilBorax (sisodic tetraborate) any

ynadica ciroBBoric acid methyl esterBoric trifluorideBrake fluid

HydnarB04dica cimorB

Bromin, liquid and gaseous anyBromochloromethane

05eneidatuBRTeneidatuBynalaidnatuB

RTsuoesag ,enatuBynalonatuB

ButanonynaloirtnatuB001laidnituB

Butoxyl (methosybutylacetate)ButterButtermilk

RTetateca lytuBButyl acrylateButyl alcoholButyl benzylphthalate

RTdiuqil ,enelytuBRTlocylg enelytuBRTlonehp enelytuB

Butylene phenol, p-tertiary TRynadica cirytuB

CCalcium carbide

LGetanobrac miclaCynaedirolhc muiclaC

LG)emil( edixordyh muiclaCCalcium hypochlorite (chlorinated lime) GL

05etartin muiclaCCalcium oxide (powder)Calcium phosphateCalcium sulphate (gypsum) GLCalgon (sodium hexametaphosphate) any

RTrehpmaCRTlio rehpmaC

Cane sugarCaoutchouc dispersions (Latex)Carbazol

yna)lonehp( lobraCyna)lonehp( dica cilobraC

RTedihplusib nobraCCarbon dioxide (soda water) any

RTedirolhcartet nobraC RTlio rotsaC

Caustic ammonia (ammonium hydroxide) any 05noitulos hsatop citsuaC

Caustic soda (sodium hydroxide) anyCD 2 up to 5%CD 3 up to 5%Cetyl alcohol

ynadica citecarolhCynaetardyh larolhC

RTT enimarolhCLVT enimarolhC

1dica cirolhC01dica cirolhC02dica cirolhC

Chlorinated carbon dioxide esterChlorinated lime (calcium hypochlorite) GL

001niffarap detanirolhCLVenirolhCLGenirolhC5,0pmad ,suoesag ,enirolhC0,1pmad ,suoesag ,enirolhC79pmad ,suoesag ,enirolhCRTyrd ,suoesag ,enirolhCRTdiuqil ,enirolhC

Chloroacetic acid ethyl ester TRChloroacetic acid methyl ester TR

Chemical resistance list

69

40 60

Page 72: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

70

Dextrose (glucose, grape sugar) anyRTetardyh nimaiD

Diethyl ether (ether, ethyl ether) TRDiethylene glycolDi-2-ethylhexylphthalate (DOP)Diethyl ketone1,2-Dibromoethane

RTrehte lyhtubiDRTetalahthplytubiDRTetacabeslytubiDRTenelyhterolhciDRTeneznebrolhciD

05dica citecarolhciDRTdica citecarolhciD

Dichloracetic acid methyl ester TRDichlorodiphenyltrichlo romethane

(DDT, powder)DichlorpropaneDichlorpropene

001)lio remrofsnart( cirtceleiDHleuf leseiD03dica cilocylgiDLGdica cilocylgiDRTetalahthplyxehiDRTenoteklytubosi-iD

Di-isopropyletherRTenimalyhtemiDRTedimamroflyhtemiD

DimethylsulfoxideDisodic phosphateDisodic sulphateDisodic tetraborate (Borax) any

RTetalathplynoniDRTetalathplytcoiD

RTnaxoiDDiphenylamineDiphenyloxideDispersionsDistilled oilsDodecyl benzene sulphonic acidDry potash (potassium hydroxide) 50Dyes

EElectrolytechbaths for electroplating Emulsifying agentsEmulsifying agents (Tenside) anyEmulsionen (photographic) HEpichlorohydrinEpichlorohydrinEpsom salts (magnesium sulphate) anyEthaneEthanol (rectified spirit, ethyl alcohol,

69)tirips eniwEther (sulphuric ether, diethyl ether) TR

RTetateca lyhtEEthyl alcohol (rectified spirit, ethyl alcohol,

69)tirips eniwEthyl alcohol, denatured (2% Toluol ) 96Ethyl alcohol (fermation mash) GEthyl alcohol + acetic acid

G)xim noitatnemref(RTenezneb lyhtE

RTlozneborolhCRTmroforolhCRTsuoesag ,lyhtemorolhCRTdica cinohplusrolhC

Chromanode mud02dica cimorhC05dica cimorhC

Chromic acid/sulphuric acid/water, 50/15/35

ynamula cimorhCynatlas suomorhC

RTdica ciruhplus muimorhCynadica ciruhplus muimorhC

05edixoirt muimorhCynadica cinocartiCynaetartiCynadica cirtiC

RTedyhedlanortiCCitrus juicesClophene

(polychlorinated biphenyls PCB) 100Coal tar oilCoca Cola

GaocoCRTlohocla lio tunocoCRTlio tunocoC

Cod liver oilGeeffoC

CognacCola conzentrateCompressed air containing oil Cooking oil, vegetable and animal

LGedirolhc reppoCynaedinayc reppoC

Copper fluoride03etartin reppoCLGetartin reppoCLGstlas reppoCynaetahplus reppoC

RTlio nroCCorsolin (disinfectant;

chlorophenol soap solution) VLCover paintCreosote

09loserC001loserC

RTodyhedlanotorCCrude oil

RTdica enillatsyrCCrystal oil (solvent naphtha) TRCumarone resin

LenonalcyCHenonalcyCRTenaxeholcyCRTlonaxeholcyCRT)enonA( enonaxeholcyC

DDecahydronaphtalene (Decalin) TRDessicator oilDetergentsDeveloping solutions (photographic)

81enirtxeD

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° ° °C

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° ° °C

Chemical resistance list

Page 73: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Fruit juices, unfermentedFruit juices, fermented

Heniw tiurFHplup tiurF

Fruit tree carbolineumHlio leuFRTlohocla rufruF

FurfurolFurniture polish

GGas liquor

ynaenitaleG04niG

Gypsum (calcium sulphate) GLGlauber’s salt (sodium sulphate) anyGlucose (grape sugar, dextrose) anyGlue

Heulg enitulGynanirecylG

Glycerin chlorohydrineLVllococylG

HlocylG73dica cilocylG07dica cilocylG

Glycolic acid butyl esterGlysantineGrape sugar (glucose, dextrose) anyGravy

HHalothane

RTenatpeH RTenatpeH-n

Hexadecanol (cetyl alcohol) 23dica cicilisoroulfaxeH ynaenimaxeH

RTenaxeH RTenaxeH-n RTloirtnaxeH

Höchst drilling agentHoneyHydraulic fluid

Ledixordyh enizardyHHydroammonium sulphate(ammonium hydrosulphate) any

05dica cimorbordyHynadica cirolhcordyH

Hydrochloric gas, dry+damp TRHydrocyanic acid (prussic acid) 10

RTdica cinaycordyH05dica ciroulfordyH07dica ciroulfordyH

RTnegordyHHydrogen bromine, gaseous TR

01edixorep negordyH03edixorep negordyH09edixorep negordyHLGedihplus negordyH

Hydrogen sulphide, gaseous TR03edyxorepus negordyH09edyxorepus negordyH

LenoniuqordyH

RTedirolhc lyhtEEthylene

RTedirolhc enelyhtERTnirdyhorolhc enelyhtE

Ethylene dichloride (Ethylene chloride)RTenimaid enelyhtE

Ethylene diamin tetra-acetic acidEthylene bromideEthylene chloride (dichlorethylene)

RTlocylg enelyhtERTsuoesag ,edixo enelyhtERTdiuqil ,edixo enelyhtE

Ethyl ether (Ether, Diethylether) TR2-ethylhexanol

RTcitahpla ,retsEExaust gases, containing hydrogen fluoride S

containing hydrogen fluoride ≤ Scontaining carbon dioxide anycontaining carbon monoxide any

Sedixo cirtin gniniatnoccontaining nitric oxide ≤ 5

5 >edixo cirtin gniniatnocSmuelo gniniatnoc

containing oleum ≤ 5containing hydrochloric acid anycontaining sulphur dioxide anycontaining sulphuric acid anycontaining sulphuric acid (damp) anycontaining sulphur trioxide (oleum) Scontaining sulphur trioxide (oleum) ≤ S

FFatty alcoholFatty alcohol sulphonate (cyclanone) L

Hetanohplus lohocla yttaFFatty acids (technically pure) 100

RTsdica yttaFFatty acid amidesFermentation mash (ethyl alcohol) GFermentation mix

(ethyl alcohol + acetic acid) GLGedirolhc suorreFynaedirolhc cirreF

Letartin cirreFLGetahplus cirreFynaetahplus suorreFynastlas rezilitreF

Hlio eldeen riFFixative salt (sodium thiosulphate) anyFloor polishFlowers of sulphur (elementary sulphur

RT)mrof redwop niRTediroulF

Fluobolic acid04)nilamrof( edyhedlamroF

Formalin (acqueous formaldehyde) 40 RTedimamroF 01dica cimroF 05dica cimroF 58dica cimroF RTdica cimroF00121 noerF

Gseciuj tiurF

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° 40° 60°C

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° 40° 60°C

Chemical resistance list

71

Page 74: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

72

23dica ciroulfocilisordyHynadica ciroulfocilisordyH

LVetihplusordyH21etahplus enimalyxordyH

Hypochlorous acidynaetihpsohpopyH

IInk

5tnega gnicalretnIGsedicitcesnI

lodine-potassium iodide (3% iodine)Isobutyl alcohol

RTenatco-osIIsopropanol (isopropyl alcohol) TR

001etateca lyporposIRTrehte lyporposI

Isobutylaldehyde (technically pure) 100Iron (Ill) ammonium sulphate GL

ynastlas norI

JHmaJ

Javel water (sodium hypochlorite) 5Jelly

Kynadnuorg/dehsaw ,niloaK

RT)muelortep( enisoreKKetoneKitchen salt, saturated (sole) 100

LLactose

RTnilonaLynadica citcaL

Latex (caotchouc dispersions)ynaetateca )lI( daeL

Lemon aromaLemon juiceLemon zest

LG)edixordyh muiclac( emiLLime water

RTlio deesniLHeerf elozneb ,sag gnithgiL

Levoxin 15 (diamin hydrate) TRLiquid soap

HrouqiLLemonadeLipoids (lecithin, emulsifiers) anyLithium bromideLixtone – SOLixtone TS 803/M

Hslio tnacirbuLLubricant soapLysoform (disinfectant; acqueous solution

LV)sedyhedla rehgih .ravLysol

MLGetanobrac muisengaMynaedirolhc muisengaM

Magnesium fluorsilicateLGedixordyh muisengaM

Magnesium iodideynastlas muisengaMynaetahplus muisengaM

LGdica cielaM1dica cilaM05dica cilaMLGdica cilaM

Manganese sulphateMargarine

RTlio enihcsaMMashed potatoMashesMayonnaise

HsessaloMMolasses aroma

RTlohtneMRTedirolhc cirucreMLGstlas cirucreMRTyrucreM

Mersol D (mixture of higherparaffin sulfonic acid chlorides) 100

Metallic mordantMetallic soapMethacrylic acid

RTsuoesag ,enahteMyna)lohocla lyhtem( lonahteM

RTlonatubyxohteMMethoxybutyl acetate (butoxyl)

yna)lonahtem( lohocla lyhteMRTetateca lyhteM

Methyl acrylate23enimalyhteMRT)loulot( enezneblyhteMRTsuoesag ,edimorb lyhteMRTedirolhc lyhteM

MethylcyclohexaneRTedirolhc enelyhteMRTenotek lyhte lyhteM

Methyl glycolMethyl isobutylketoneMethyl metacrylate4-Methyl-2-pentanolMethyl propylketonn-Methyl pyrrolidoneMethylsalicylate (Salicylic acid methyl ester)

05dica ciruhplus lyhteM001dica ciruhplus lyhteM

Metol (4-methyl-amino-phenosulphate)(photographic-developer) VL

HkliMMineral oil, without additivesMineral oil, free of aromatic compounds H

Hretaw lareniMMixed acid I

(sulphuric acid/nitric acid/water)48/49/ 350/50/ 010/87/ 3

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° 40° 60°C

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° 40° 60°C

Chemical resistance list

Page 75: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

73

RTnegyxOOzone, gaseous 50 pphmOzone, gaseous 2%

LGenozO

PP3 Galvaclean 20 (dangerous substance)P3 Galvaclean 42 = P 3 S(dangerous substance)

P3 Galvaclean 44 (dangerous substance)P3 Galvaclean 45 (dangerous substance)P3 Galvaclean 65 (dangerous substance)P3 Manuvo hand cleaner (dangerous substance)P3 Saxim (dangerous substance)P3 Standard (dangerous substance)P3 7221 (dangerous substance)Palmityl acidPalmityl alcoholPalm kernel oil

Hlio mlaPRTdica lio lenrek mlaP

Paraffin 100Hnoislume niffaraP

RTlio niffaraPParaformaldehydeParfumeParis inert oxyd (dangerous substance)Peanut oilPectin GL

RTlonatnePRTlio tnimreppePRTenelyhterolhcreP02dica cirolhcreP05dica cirolhcreP07dica cirolhcreP

Perhydrol (hydrogenperoxide, acqueous solution) 40RTrehte muelortePRT)enesorek( muelorteP

Petroleum spirit (light petrol,free from aromatic compounds) 100

Hedarg raluger ,lortePHnoislume cihpargotohPHrepoleved cihpargotohPHhtab rexif cihpargotohP

Pineapple juicePine needle oil

yna)dica cilobrac( lonehPPhenol resin mould substances

LG)enilina( enimalynehPPhenylethyl alcohol

RTenizardyhlynehPPhenylhydrazine hydrochloridePhenyl sulphonat(Sodium dodecylbenzene sulphonate)

RTsuoesag ,enegsohPRTdiuqil ,enegsohPynasetahpsohP

Phosphoroxichloride001edixotneprohpsohP

05dica cirohpsohP59dica cirohpsohPRTedirolhcirtrohpsohPRTedirolhc lyrohpsohP

50/31/1950/33/1710/20/70

Mixed acid ll(sulphuric acid/phosphoric acid/water)30/60/10

MonochlorbenzeneMonochloracetic acid ethyl ester 100Monochloracetic acid methyl ester 100

ynaenimalyhteonoMRTenilohproM

Motor oilMowilith-dispersions

NNail varnishNail varnish remover

HahthpaNRTnilahthpaN

Hsag larutaNNekal BX (interlacing agent; sodium salts

var. isopropyl naphthaline sulphonic acids) anyLGedirolhc lekciNLGetartin lekciNLGstlas lekciNynaetahplus lekciN

NicotineLVdica cinitociN3,6dica cirtiN52dica cirtiN04dica cirtiN05dica cirtiN56dica cirtiN57dica cirtiN

NitrochloroformRTeneznebortiN

Nitrocelluloseyna)suoesag( negortiN

Nitrous gases ≤ 5RTsloulotortiN

Nolan stop-off lacquer (dangerous substance)Nolan thinner (dangerous substance)Nonyl alcohol (nonanol)Nut oil

ORTloserc lytcO

Oleic acidOil of clovesOils, distilledOils, mineral, without additivesOils, mineral, free of aromatic compounds HOils, vegetable and mineral HOleum, 10% SO3Oleum vapours (sulphur trioxid) ≤ 5

RTsruopav muelORTdica cielORTloulutortin-O

Optical whitenersOrange juiceOrange zestOrotol

LGdica cilaxO

Chemical resistance list

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° 40° 60°C

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° 40° 60°C

Page 76: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

74

Prussic acid (hydrocyanic acid) 10 Pseudocumol

RTenidiryPQQuinine

RRatak Resit 65 (Fuchs)Rectified spirit (ethanol, ethyl alcohol, spirit of wine) 96

Hstnega gnisniRynayrd ,sesag retsaoR

04muR

SLGdica cirahccaS

Sagrotan (disinfection, chlorophenol soap solution) VL

SagrotanLGdica cilycilaS

Salicylic acid methyl ester (methylsalicylate)Sal-ammoniac (ammonium chloride) any

yna)edirolhc muidos( tlaSSaturated steam concentrate

HretawaeSSeparating agentSewageShampooShoe cream

ynadica ciciliS04dica ciroulfociliSynaetartin revliS LGstlas revliS

RTlio nociliSyna)etanobrac muidos( adoSynanoitulos paoS

Soda Iye (sodium hydroxide, caustic soda) anySoda water (carbon dioxide) any

ynaetateca muidoSSodium aluminium sulphate

LGetaozneb muidoS63etaozneb muidoS

Sodiumbicarbonate (sodiumhydrogencarbonate) GLSodium bisulphate (sodium hydrogen sulphate) GLSodium bisulphitt (sodium hydrogen sulphite, sodium disulphite) any

Sodium borateLetamorb muidoSLedimorb muidoS

yna)ados( etanobrac muidoSynaetarolhc muidoSyna)tlas( edirolhc muidoS

LVetirolhc muidoS02etirolhc muidoS

Hsehcaelb etirolhc muidoSLVetamorhc muidoSLGedinayc muidoSLGetamorhcid muidoS

Sodium disulphite (sodium bisulphite) anyLVetinoihtid muidoS

Sodium dodecyl benzene sulphonate(phenyl sulphonate)

Sodium ferricyanide

05dica cilathPLGdica cilathP

Phtalic acid ester1dica circiP

LGdica circiPPolychlorinated biphenyl (PCB)Polyester resinsPolyester softenersPolyglycolsPork drippingPotash (potassium carbonate) anyPotassium ferrocyanide, pot. ferricyanide anyPotassium ferricyanide

and potassium ferrocyanide anyynaedinayc muissatoP

Potassium ammonium sulphate (alum) anyynaetanobrac muissatoP

Potassium bichromate (potassium dichromate) anyynaetahplusib muissatoP

01etarob muissatoPLGetarob muissatoPLVetamorb muissatoPLGetamorb muissatoPynaedimorb muissatoP

Potassium cadmium cyanide anyPotassium carbonate (potash) any

ynaetarolhc muissatoPynaedirolhc muissatoP

04etamorhc muissatoPLGetamorhc muissatoPynaedinayc muissatoP

Potassium dichromate (potassium bichromate) anyynaedinaycirref muissatoPynaediroulf muissatoP

Potassium hexacyano ferrate anyPotassium hydroxide (caustic potash) 50

ynaedidoi muissatoPynaetartin muissatoP

Potassium perborateLGetarolhcrep muissatoP02etanagnamrep muissatoPLGetanagnamrep muissatoPynaetahplusrep muissatoPynaetahpsohp muissatoPynaetahplus muissatoP

Letihplus muissatoPPotassium sulphitePotassium tetracyanocupratePotassium thiosulphate

RTdiuqil ,enaporPRTsuoesag ,enaporP

RTlonaporP-in-Propanol (n-propyl alcohol) TR

7lohocla lygraporP05dica cinoiporPRTdica cinoiporP001edirolhc enelyporP

RTlocylg enelyporPRTedixo enelyporP

RTdica cissurP

Chemical resistance list

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° ° °C

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° ° °C

Page 77: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

75

TTaningan extra (synthetic tanning substances) GL

01)eninnat( dica cinnaT01)dica cinnat( ninnaT

GaeTTar

ynadica ciratraTRTenitnepruT

TetrabromethaneRTenahteorolhcarteTRTenelyhteorolhcarteTRTdael lyhtearteTRTenarufordyharteT

Tetrahydronaphthalin (Tetralin) TRThioglycol (thiodiethylene glycol) 100Thioglycolic acid

ynaedibamracoihTRTedirolhc lynoihT

RTenehpoihTH6BAD enidoi fo erutcniT

Tiutol (hypochlorite Javel water) 12/13RT)enezneb lyhtem( louloT

Tomato juiceRTlio remrofsnarTRTenimalonahteirT

Triethylene glycolRTetahpsohp lytubirT001suoesag ,enahteorolhcirT

RTenahteorolhcirTRTenelyhteorolhcirT

TrichlorobenzeneTrichlorethylphosphate

05dica citecaorolhcirTRTdica citecaorolhcirT

Trichlorofluorethane (freon 11, Sdp. 24°C) 100RTenimalonahteirTRTetahpsohplysercirT

TrilonTrimethylborateTrimethylolpropaneTrisodium phosphate

RTetapsohplytcoirTT-SS up to 5%Two-stroke oilTypewriter oil

UUniversal thinners

LGdica cirU33enirU

V RTlio enilesaV

H)rageniv eniw( rageniV RTetateca lyniV

Viscose spinning solutionsVitamin C (ascorbic acid)

LGediroulf muidoSLGetarrefonaycaxeh muidoS

Sodium hydrogen carbonateLG)etanobracib muidos(

Sodium hydrogen sulphate (sodium bisulphate) 10Sodium hydrogen sulphite (sodium bisulphite) anySodium hydroxide (caustic soda) anySodium hypochlorite (Javel water) 5

5,21etirolhcopyh muidoSLedidoi muidoS

ynaedinayc reppoc muidoSynaetartin muidoSynaetirtin muidoS

LGetalaxo muidoSynaetarobrep muidoS

Sodium perchlorate01edixorep muidoSLGedixorep muidoS

Sodium peroxodisulphate (sodium persulphate) GLLGetahpsohp muidoS

Sodium silicate (water glass) anySodium sulphate (Glauber’s salt) any

ynaedihplus muidoSLGetihplus muidoS

Sodium thiosulphate (fixative salt) anySoftenersSoya oilSpermacetiSperm oil alcohol (mixture of higher oil alcohols) 100

RTlio eldnipSSpin bath acid, containing CS2 0,01

HstiripSStain remover

ynaedirolhc )lI( suonnatSynahcratSynapurys hcratS

RTdica ciraetSStellhefen flavouring (aqueous solution of maltose and dextrines) L

Styrolynadica ciniccuS

RTteuSynaeciuj teeb raguSynasnoitulos raguS

Hpurys raguSynaetahpluS

RTruhpluSRTedirolhcid ruhpluSynaedixoid ruhpluS

Sulphur dioxide, gaseous, dry and damp anyRTdiuqil ,edixoid ruhpluS

Sulphurated potash (potassium polysulphide) any 01dica ciruhpluS07dica ciruhpluS09dica ciruhpluS

Sulphur sodium (sodium sulphide) anySulphur trioxide (oleum vapours) ≤ 5

RTedixoirt ruhpluSLGdica suoruhpluS

Chemical resistance list

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° 40° 60°C

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° 40° 60°C

Page 78: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

76

WRTslohocla xaW

WaxesWalnut oil

Gstnega gnihsaWWashing up liquidWater, distilliedWater, fully desalinizedWater de-ionizedWater chlorinated driking waterWater, ozonized drinking waterWater glass (sodium silicate) any

Helbategev ,elttaWHesolullec morf ,elttaWHeniWH)raegeniv( raegeniv eniW

Wine spirit (ethyl alcohol, ethanol, rectified spirit) 96RTtirips etihWRT)lio latsirc( tirips etihW

HyksihWWhwy

Gniats dooW

XRT)erutxim remosi( enelyX

YynatsaeY

ZZampon thinners

LGetanobrac cniZynaedirolhc cniZ

LGedixo cniZynastlas cniZ

Zinc sludgeynatsud cniZ

Zinc stearateynatahplus cniZ

Chemical resistance list

Geberit HDPEProport. Performance at

02%ecnatsbus hguorht wolF ° ° °C

Page 79: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Geberit named in top 10 most sustainable companies globally.

Geberit is a proven international leader in the area of sustainability. Having recently been named among the top 10 most sustainable companies in the world from a study conducted by media company, Corporate Knights, further “supports and validates Geberit’s continuing commitment to be environmentally responsible in everything we do,” said Managing Director of Geberit Australia. Saving water, resource efficiency and sustainable construction are core areas of concern for the Geberit organisation both globally and locally. A key focus for Geberit Australia is to continually update, integrate and effectively implement a sustainable strategy that will make a positive impact today and tomorrow.

Geberit believes that sustainability must be lived in all company sectors. Geberit aims to be a role model to and set standards for partners, customers and suppliers. This includes safe, environmentally friendly and resource efficient production with an increasing proportion of renewable energies, procurement and logistics with high environmental and ethical standards ensuring that the entire manufacturing process of all products comply with the highest standards in environmental protection, social responsibility and ethical action.

Sustainability means satisfying the needs of today’s generation in a manner that will ensure a solid basis for the livelihoods of future generations. To assist in achieving this, Geberit provides 100% recyclable HDPE Polyethylene (PE) is a simple compound of carbon and hydrogen atoms, harmless to man, animals and plants. PE is the perfect ecological solution as it has a long life span and does not excrete toxic gases during incineration during disposal and consumes much smaller quantities of energy. All Geberit manufacturing sites are compliant to the latest ISO standard (ISO 9001 & 14001).

77

SQS CertificateISO 9001:2008ISO 14001:2004

Watermark CertificateAS/NZS 4001:2006

Watermark CertificateAS/NZS 5065:2005

Standards:Geberit HDPE conforms to:AS/NZS 4401 Plastic piping systems for soil and waste discharge (low and high temperature) inside buildings - Polyethylene (PE).AS/NZS 5065 Polyethylene and Polypropylene pipes and fittings for drainage and sewerage applications.

Certification for Geberit HDPE

Page 80: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Certification for Geberit HDPE

KOMO certificate for quality of construction materials.

EN DIN

European Quality CertificateFor its manufacturing plants Geberit has received the highest qualitysystem certification available, issued by the Swiss EQ-Net member SQS for compliance with the ISO 9001/14001.EQ-Net members are in all countries throughout Europe, including BSI QA United Kingdom.

EN ISO Standard9001

ISO Standard14001

British Board of Agrément

Geberit HDPE pipes and fittings have

been certified by many European

authorities and in 1976 also received

BBA certification. The British Board of

Agrément, in consultation with the

secretary of state, reissued the BBA

Certificate 92/2796 in 1992. Geberit

pipes, adapters and fittings also comply

with ISO R 161/1 recommendations.

Institute of Plumbing

Geberit is an industrial associate

member of the Institute of Plumbing.

Instituto Italiano dei Plastici

Certificate of the CISQ and the SQP

independent certification of quality.

WPC/World Plumbing Council

Geberit is an active member of the

renowned World Plumbing Conference

Standards

Geberit HDPE conforms to:

EN 1519 Plastic piping system for soil and waste discharge (low and high temperature) within building structure

DIN 19535-10 High-densitiy polyethylene (PE-HD) pipes and fittings for hot water resistant waste and soil discharge systems (HT) inside buildings – Part. 10 Fire behaviour, quality control and installation recommendations

SKZ (SüddeutschesKunststoffzentrum) Europe's leading authority forregular product and production qualityassurance of Geberit pipes

EN 12666 Plastics piping systems for non-pressure underground drainage and sewerage - Polyethylene (PE)

78

Page 81: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration
Page 82: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration
Page 83: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration
Page 84: Geberit HDPE Application Technique - Reece Plumbing · Geberit HDPE Application Technique. 100 212 ... Anchor brackets and guide brackets Installation examples ... Pipe penetration

Geberit HDPE – the universal pipe system

Geberit Pty Ltd

Unit 8a

6-8 Byfield Street

NORTH RYDE NSW 2113

T: (02) 9889 7866

F: (02) 9889 7855

E: [email protected]

www.geberit.com.au The

info

rmat

ion

cont

aine

d is

sub

ject

to c

hang

e w

ithou

t not

ice.

The

info

rmat

ion

prov

ided

con

tain

s ge

nera

l des

crip

tions

of t

he te

chni

cal o

ptio

ns a

vaila

ble,

whi

ch d

o no

t alw

ays

appl

y to

indi

vidu

al c

ases

.Th

e re

quire

d fe

atur

es s

houl

d th

eref

ore

be in

divi

dual

ly c

larif

ied

in a

ccor

danc

e w

ith in

divi

dual

situ

atio

ns a

t the

tim

e of

pro

ceed

ing.

All

dim

ensi

ons

in m

m (1

0mm

= 1

cm).

Thi

s pu

blic

atio

n G

EA

U46

0411

supe

rsed

es a

ll pr

evio

us p

ublic

atio

ns.

©C

opyr

ight

Geb

erit

Pty

Ltd

/ A

pril

2011

.

from the roof to the underground