GEA Sterilcap VHP R · 2020. 6. 4. · Title: Sterilcap VHP R caps sterilizer - Brochure Author:...

2
Sterilcap VHP R is a caps sterilizer based on a sterilizing effect of H2O2 in vapor form at the right concentration and temperature, where the caps remain for a time, long enough to guarantee up to 6 log reductions. The design of the chutes inside the machine ensures that all the cap surfaces are exposed to prevent any shadowed area. Sterilcap VHP R is located on the top of the filler in order to feed the capper by gravity and has a very compact layout. Decontamination parameters ensure a gentle treatment without removing the caps slipping agent. Since VHP is a genuine dry sterilization technology, it does not use any water. Sterilcap VHP R is also capable to treat both sport and flat caps in the same machine, moreover it is able to perform a fast changeover without losing sterility. The system represents the perfect cap sterilization solution to be coupled with the GEA ABF (Aseptic Blow Fill) in order to allow the usage of one single chemical sterilizing media. It also can be coupled with any other solution where an aseptic filler is combined with a traditional blower. In addition to an excellent sterilization performance, the Sterilcap VHP is designed to create a buffer of caps to guarantee the necessary redundancy required by a blow fill solution: in case of cap jamming the aseptic blow filling bloc can be emptied with no loss of preforms or bottles. GEA Sterilcap VHP R Vapor Hydrogen Peroxide caps sterilizer

Transcript of GEA Sterilcap VHP R · 2020. 6. 4. · Title: Sterilcap VHP R caps sterilizer - Brochure Author:...

  • Sterilcap VHP R is a caps sterilizer based

    on a sterilizing eff ect of H2O2 in vapor

    form at the right concentration and

    temperature, where the caps remain for

    a time, long enough to guarantee up to

    6 log reductions. The design of the chutes

    inside the machine ensures that all the cap

    surfaces are exposed to prevent any

    shadowed area.

    Sterilcap VHP R is located on the top of

    the fi ller in order to feed the capper by

    gravity and has a very compact layout.

    Decontamination parameters ensure a

    gentle treatment without removing the

    caps slipping agent. Since VHP is a

    genuine dry sterilization technology, it

    does not use any water. Sterilcap VHP R

    is also capable to treat both sport and fl at

    caps in the same machine, moreover it is

    able to perform a fast changeover without

    losing sterility.

    The system represents the perfect cap

    sterilization solution to be coupled with

    the GEA ABF (Aseptic Blow Fill) in order

    to allow the usage of one single chemical

    sterilizing media. It also can be coupled

    with any other solution where an aseptic

    fi ller is combined with a traditional blower.

    In addition to an excellent sterilization

    performance, the Sterilcap VHP is

    designed to create a buff er of caps to

    guarantee the necessary redundancy

    required by a blow fi ll solution: in case of

    cap jamming the aseptic blow fi lling bloc

    can be emptied with no loss of preforms

    or bottles.

    GEA Sterilcap VHP RVapor Hydrogen Peroxide caps sterilizer

  • GEA Sterilcap VHP R

    Vapor Hydrogen Peroxide caps sterilizer

    GEA Italy

    GEA Procomac S.p.A.

    Via Fedolfi, 29

    43038 Sala Baganza (Parma), Italy

    Tel +39 0521 839411

    Fax +39 0521 833879

    gea.com/contact

    gea.com/filling

    Features

    • Compact layout

    • Sterilizing area physically isolated

    • Eff ective VHP treatment: up to 6 log reduction on

    B. atrophaeus ATCC9372 on both internal and external

    caps surfaces

    • Uniform H2O2 concentration

    • Gentle treatment and handling

    • No slipping agent removal

    • No water consumption

    • Suitable for high speed lines

    • Suitable for High Acid and Low Acid products

    Stand alone configuration

    • Integrated H2O2 sterilizing solution preparation and dosing

    • Possible retrofi t on GEA PAA wet aseptic line for dry solution

    and sport caps handling

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s br

    ochu

    re m

    erel

    y se

    rves

    as

    a no

    n-bi

    ndin

    g de

    scrip

    tion

    of o

    ur p

    rodu

    cts

    and

    is w

    ithou

    t gu

    aran

    tee.

    Bin

    ding

    info

    rmat

    ion,

    in p

    artic

    ular

    rel

    atin

    g to

    cap

    acity

    dat

    a an

    d su

    itabi

    lity

    for

    spec

    ifi c

    appl

    icat

    ions

    , can

    onl

    y be

    pro

    vide

    d w

    ithin

    the

    fra

    mew

    ork

    of c

    oncr

    ete

    inqu

    iries

    . Prin

    ted

    on c

    hlor

    ine-

    free

    ble

    ache

    d pa

    per

    · Sub

    ject

    to

    mod

    ifi ca

    tion.

    Mod

    . 797

    - 0

    9/20

    17

    Sport and flat caps changeover without losing sterility

    • Sport and fl at caps automatic changeover

    • No need of mechanical intervention for caps changeover

    • No loss of sterility

    • Intervention gloves in case of caps jam intervention without